Loading...
RC-12-1175Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 186934 Permit Number: RC -6 -12 -1175 Scheduled Inspection Date: March 11, 2013 Inspector: Bruhn, Norman Owner: RIVERA, FRANZ AND JASMIN Job Address: 10255 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ORONI INC Permit Type: Residential Construction Inspection Type: Final Building Work Classification: Garage Enclosure Phone Number (786)200 -6605 Parcel Number 1132050190070 Phone: (305)685 -0412 Building Department Comments GARAGE ENCLOSURE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed /-/13 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. March 08, 2013 For Inspections please call: (305)762 -4949 Page 29 of 41 Miami Shores Viiiage Building Department 3n- (cJcS ‘q 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CERTIFICATE OF OCCUPANCY /COMPLETION CHECK LIST Building permit card. ❑ Surveys (2 copies) Final as built - Required Items: Elevations of buildings showing all intended setbacks from property lines and other existing structures. Ingress+ Egress, required parking spaces, Wheel stops, stripping, and all paving to exterior. ❑ Certificate of Elevation — (Sealed by surveyor). Expiration date required on the form. Certificate of Insulation. ❑ Certificate of Soil Treatment (Final treatment - original)\ CHAPTER 2913 -5 TERMITE PROTECTION: "This Building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and law as established by the Florida Department of Agriculture and Consumer Services." ❑ Health Department Approval Letter (On septic or private water). Note: If the house is on septic tank, approval letter is required from Health Dpt. ❑ Soil Compaction Letter (Density report is required) ❑ Final certification letter from the Engineer /Architect (on masonry, trusses, special structure, etc) ❑ Backflow preventor certificate (Required on commercial projects only) ❑ Certificate of use. (Recorded in Miami -Dade Clerk of Courts) PLEASE NOTE THAT THE SAME ITEMS ARE REQUIRED FOR TEMPORARY CO • Emergency CO (Without 24 Hrs Processing) Additional fee is $80.00. • Temporary CO (Up to 90 days max) $75.00. • Residential CO fee is $150.00 • Commercial CO is $200.00 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 186529 Permit Number: RC -6 -12 -1175 Inspection Date: February 28, 2013 Inspector: Bruhn, Norman Owner: RIVERA, FRANZ AND JASMIN Job Address: 10255 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ORONI INC Permit Type: Residential Construction Inspection Type: F. Insulation Certificate Work Classification: Garage Enclosure Phone Number (786)200 -6605 Parcel Number 1132050190070 Phone: (305)685 -0412 Building Department Comments GARAGE ENCLOSURE Infractio Passed Comments INSPECTOR COMMENTS False Passed Inspector Comments /77 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until For Inspections please call: (305)762 -4949 February 28, 2013 Page 1 of 1 • 1116 OBONI, INC. A Construction Company 1CBC12516541 (305) 685 -0412 (OH) 14040 NW 6th Court (305) 688 -9550 (Fax) Miami, Florida 33168 ENERGY, SOUND AND IMPACT CERTIFICATE Building Permit Number: cZC - ` k2° Project Name: 9-Vv r Ls C v tG Job Address: i 02_5r e IS ctty/JG- g, STATEMENT OF COMPLIANCE We the undersigned hereby verify that the ENERGY, SOUND AND IMPACT INSULATION has been installed in the above referenced project in compliance with the latest edition of the FLORIDA BUILDING CODE, the APPROVED ENERGY CALCULATIONS, and PLANS in accordance with good construction practices. The insulation finished and installed has the characteristics shown below (check only the applicable numbers). 1641. Exterior CBS walls insulation R- c 1- -(Mm) Material Thickness inch(es) Density lb /ft Mfgr #2. Exterior Frame Metal Stud Walls R- (Mm) Material Thickness inch(es) Density lb /ft Mfgr #3. Exterior solid concrete walls R- (Mm) Material Thickness inch(es) Density lb/ft Mfgr #4. Interior walls separating A/C from space insulation R- (Mm) Material Thickness inch(es) Density lb /ft #5. MULTY - FAMILY RESIDENTIAL CONSTRUCTION ONLY. The COMMON (Party) walls to two separate conditioned tenancies shall be insulated to a minimum of R -11 for framing walls and to R -3 on both sides of common masonry walls. See ENERGY CODE 2007 paragraph 13 -602 ABC 1 1, on page 1374, latest edition. These "minimum levels of insulation ", are not included in the Energy Calculations, but shall be installed in the field. #6. Ceiling insulation R- (Mm) Materials Thickness inch(es) Density lb /ft Mfgr #7. Wall partitions and floor ceiling assemblies between dwelling units or between dwelling units and adjacent public or service areas such as halls, corridors, stars, etc. must have a sound transmission class (STC) of not less than 50 (penetration must maintain the required rating). #8. Floor ceiling assemblies between dwelling units or dwelling units and public or service areas such as halls, corridors, stars, etc. must have an impact insulation class (IIC) rating us not less than 50. #9. Others: "�"1 ��J�{ $ Jca- 1 i..i xR Installed by (Insulation Company Name) C>g-C911/43 1 NC- (Insulation Company Signature) Insulation Contractor CC#: OC Builder (Company Name): Building contractor CC#: CigCAU 611' Date Certified: * G- OC Builder Signature: Date Certified: Note: For lightweight Insulation concrete use appropriate forms, separate from this one. Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 186528 Permit Number: RC -6 -12 -1175 Inspection Date: February 28, 2013 Inspector: Bruhn, Norman Owner: RIVERA, FRANZ AND JASMIN Job Address: 10255 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ORONI INC Permit Type: Residential Construction Inspection Type: F. Elevation Certificate Work Classification: Garage Enclosure Phone Number (786)200 -6605 Parcel Number 1132050190070 Phone: (305)685 -0412 Building Department Comments GARAGE ENCLOSURE Infractio Passed Comments INSPECTOR COMMENTS False Passed Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until February 28, 2013 For Inspections please call: (305)762 -4949 Page 1 of 1 I U S. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY National Flood Insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1 -9. SECTION A - PROPERTY INFORMATION Al. Building Owner's Name FRANZ E RIVERA &W JASMIN K OMB No. 1660 -0008 Expiration Date: July 31, 2015 A2. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 10255 BISCAYNE BLVD City , MIAMI SHORES, State FL ZIP Code 33138 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 7 BLOCK 175 OF "NIAMI SHORES SEC 8" PB 43, PG 67 OF MIAMI -DADE COUNTY PUBLIC RECORDS A4. Building Use (e.g., Residential, Non - Residential, Addition, Accessory, etc.) A5. Latitude/Longitude: Lat. 25 °52'1187"N Long. 80°10'2594'W A6. Attach at least 2 photographs of the building if the Certificate is being used A7. Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosures) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosures) within 1.0 foot above adjacent grade NJA c) Total net area of flood openings in A8.b WA sq in d) Engineered flood openings? ❑ Yes ❑ No RESIDENTIAL Horizontal Datum: to obtain flood insurance. ❑ NAD 1927 ® NAD 1983 A9. For a building with an attached garage: a) Square footage of attached garage N/A sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes ❑ No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number MIAMI SHORES - 120652 B2. County Name MIAMI -DADE B3. State FLORIDA B4. Map/Panel Number 12086 C 0306 B5. Suffix L B6. FIRM Index Date 09/11/2009 B7. FIRM Panel Effective/Revised Date 09/11/2009 B8. Flood Zone(s) AE B9. Base Flood Elevation(s) (Zone AO, use base flood depth) 8.00' B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other /Source: B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 ❑ NAVD 1988 ❑ Other /Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: Ni A ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones A1-A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, AR/A, AR/AE, AR/AI -A30, AR/AH, AR/AO. Complete Items C2.a -h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: B -26 -RA Vertical Datum: NGVD -1929 Indicate elevation datum used for the elevations in items a) through h) below. ® NGVD 1929 ❑ NAVD 1988 ❑ Other /Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 9.9" ® feet ❑ meters b) Top of the next higher floor 10.4' ® feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A. ® feet ❑ meters d) Attached garage (top of slab) N /A. 0 feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 8.7' 0 feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 8.6' g) Highest adjacent (finished) grade next to building (HAG) 9.3' h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support N/A. ® feet ® feet ® feet ❑ meters ❑ meters ❑ meters SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. 1 certify that the information on this Certificate represents my best efforts to interpret the data available. l understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a ❑ Check here if attachments. licensed land surveyor? ® Yes ❑ No Certifier's Name PABLO J. ALFONSO License Number 5880 Title SURVEYOR & MAPPER ompany Name ROYAL POINT LAND SURVEYORS, INC Address 6175 NW 15 Signature ty MIAMI LAKES State FL ZIP Code 33014 ate 2/25/2013 Telephone 305 - 822 -6062 FEMA Form 086 -0-33 (7/12) `,` See reverse side for continuation. Replaces all previous editions. IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 10255 BISCAYNE BLVD City MIAMI SHORES State FL ZIP Code 33138 SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments LATITUDE & LONGITUDE OBTAINE P FROM GOOGLE MAPS, CROWN OF ROAD ELEVATION IS +9.5'. Signature a.4r Date 2/25/2013 SECTION E - BUILDING ELEV .ION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ® feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA - issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA- issued or community- issued BFE) or Zone AO. G3. ❑ The following information (Items G4 -G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: G10. Community's design flood elevation: ❑ feet ❑ meters Datum ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments Check here if attachments. FEMA Form 086 -0-33 (7/12) Replaces all previous editions. _LEVATIQN CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOI t !AI USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 10255 BISCAYNE BLVD Numbe City MIAMI SHORES State FL ZIP Code 33138 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View "; and, if required, `Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. lPhotographs date taken: 2/25/13 LEFT SIDE VIEW RIGHT SIDE VIEW FEMA Form 086 -0 -33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 4 Building Photographs Continuation Page IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURAt E COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 10233 BISCAYNE BLVD City MIAMI SHORES State FL ZIP Code 33138 Policy Number: If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View "; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. GARAGE VIEW N/A VENT VIEW N/A FEMA Form 086 -0 -33 (7/12) Replaces all previous editions. Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 186530 Permit Number: RC -6 -12 -1175 Inspection Date: February 28, 2013 Inspector: Dacquisto, David Owner: RIVERA, FRANZ AND JASMIN Job Address: 10255 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: ORONI INC Permit Type: Residential Construction Inspection Type: Declaration of Use Work Classification: Garage Enclosure Phone Number (786)200 -6605 Parcel Number 1132050190070 Phone: (305)685 -0412 Building Department Comments GARAGE ENCLOSURE Infractio Passed Comments INSPECTOR COMMENTS False ck, 011 „I*04 Passed Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until For Inspections please call: (305)762 -4949 February 28, 2013 Page 1 of 1 b. attiM 1 NEVION oiatolM MMUS K MVO 01 a MOM cri cra na c— blDeAdbb� bb anatneg rl Ld rya aw WHEREAS, the undersigned f il- J is/are the fee simple owner(s) of the following described property (Property') W situated and being In Miami Shores Village, Flori d Lot((s 1. Block \ tS of tAkAPIV ' J x (Subdivision), according to the plat n thereof, as recorded in the Plat Book Page 61- of the Public Records of Miami -Dade County, Florida, (address) t 02-Er `� 1Stl�'ti1 N it 'ice L vb and WHEREAS, the undersigned owners) have sought certain development approval from Miami Shores and are providing this document in consideration thereof >- ta-and to induce the Village to grant same: tdL W ce •sc NOW, THEREFORE, for good and valuable consideration, the receipt and sufficiency of which is acknowledged, the undersigned do(es) hereby declare and U.. UPC `-' 7 ~'agree: MIAMI - ©A ©E COUNTY, PREPARED BY: DECLARATION OF USE KNOW ALL MEN BY THESE PRESENTS: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 1. That the Property will not be used in violation of any ordinance of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. 2. That the property will be used for a single family residence only. 3. That he /she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above Property and shall constitute a covenant running with the kind and shall be binding upon the undersigned, his/her successorsand assigns and may only be released by Miami Shores Village, or its successors, in accordance with the codes, rules and regulations of said Village then in effect. IN WITNESS WHEREOF, the undersigned has/have caused hand(s) and seal(s) to be affixed hereto on this Z.-% day of 200 WIT SIgna re and Print 715410 " €65h45' Signature and Prin�� STATE OF FLORIDA ) COUNTY OF MIAMI -DADE ) OWNERS: c and PrintA't-^ Signature and Print I HEREBY CERTIFY that on this day personally appeared before me , ;o✓ "Who is personally known to me or has produced i!' _. 1.(90 -Li - 4 $ato °( pe of identification) as identification and he/she acknowledge that he /she executed the foregoing, freely and voluntarily, for purposes therein expressed. 1' SWORN TO AND SUBSCRIBED before me on this 7, day of My commission eC. GF DADS jtrCErMa Ns is a We copy ofthe r. _ C9 OrL.....+- ......._ flay of . A.D. 20 WITNESS my hand ��a���nd,�O�[ffictar Seal. County Courts '�i CLERK. of'" UN,/ dC i► t l ! • T D.C. NOT tY BU , STATE OF FLORIDA CUMULATIVE SUBSTANTIAL IMPROVEMENT VERIFICATION WORK SHEET In accordance with FEMA regulation and Miami Shores Village Flood Damage Prevention Ordinance the costs of all improvements must be monitored. The costs of any improvements in the past 12 months and the costs of any proposed improvements must be shown on the worksheet. The cost of improvements must include demolition, raw and finished materials (include those donated), labor (including volunteer and self - performed), construction supervision and management, and overhead and profit. A list of items the costs of which are to be included as well as those excluded is attached for your reference. (A Copy of the Contract must be attached) PROPERTY OWNER: irl u� J Z R PERMIT # ADDRESS: ` ®-as-f- iifS vvt Pi-/D FOLIO NUMBER: I 1 ®5 ° ft ° Q©"0 FLOOD ZONE: BASE FLOOD ELEVATION: FREEBOARD: EAST OF FL.CCCL: COST OF PAST IMPROVEMENTS (12 MONTHS): COST OF PROPOSED IMPROVEMENTS: r 1(04 C) a� (ATTACH COPY OF CONTRACT) TOTAL CUMULATIVE COST OF IMPROVEMENTS (past and proposed):f 7-7 VALUE OF PRINCIPAL STRUCTURE OWNERS SIGNATURE: PLANREVIEWER: PLAN REVIEWER SIGNATURE: Created on June 2009 a , praisa ��� I :� DATE: DATE: J" Prat Folio at �v. 11- 3205 - 019 -0070 Property Address 10255 BISCAYNE BLVD Owner Name(s) FRANZ E RIVERA &W JASMIN K Mailing Address 10255 BISCAYNE BLVD MIAMI SHORES FL 33138 -2648 Primary Zone 1100 SGL FAMILY - 2301 -2500 SQ Use Code 0001 RESIDENTIAL - SINGLE FAMILY Beds /Baths /Half 5/4/1 Floors 2 Living Units 1 Adj. Sq. Footage 3,926 Lot Size 9,750 SQ FT Year Built 2005 Legal Description MIAMI SHORES SEC 8 REV PB 43 -67 LOT 7 BLK 175 LOT SIZE 75.000 X 130 OR 20331 -4204 04 2002 1 COC 23496 -4382 06 2005 1 OR 23496 -4382 0605 00 Current Previous Year 2012 2011 Land Value $147,914 $123,262 Building Value $427,22 $392,352 Market Value $575,140 $515,614 Assessed Value $555,849 $502,316 tP1 or pit ion Current Previous Year 2012 2011 Homestead .: $25,000 $25,000 2nd Homestead $25,000 $25,000 Senior $0 $0 Veteran Disability $0 Civilian Disability $0 $0 Widow(er) $0 $0 Disclaimer: MIAMI -DADE COUNTY OFFICE OF THE PROPERTY APPRAISER PROPERTY SEARCH SUMMARY REPORT Carlos Lopez - Cantera Property Appraiser N A Aerial Photography 2012 V Current Previous Year 2012 2011 Exemption /Taxable Exemption /Taxable County $50,000 / $505,849 $50,000 / $452,316 School Board $25,000 / $530,849 $25,000 / $477,316 City $50,000 / $505,849 $50,000 / $452,316 Regional $50,000 / $505,849 $50,000 / $452,316 Date Amount Recording Book -Page Qualification Code 6/2005 $945,000 23496 -4382 Sales which are qualified 4/2002 $85,000 20331 -4204 Sales which are qualified 10/2000 $38,000 19327 -1569 Other disqualified 9/1999 $0 19103 -0888 Sales which are disqualified as a result of examination of the deed 5/1979 $26,000 10410 -0558 Sales which are qualified The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and GIS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or implied, are provided for data and the positional or thematic accuracy of the data herein, its use, or its interpretation. Although this website is periodically updated, this information may not reflect the data currently on file at Miami -Dade County's systems of record. The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or inaccuracies in the information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user in reliance upon any information provided herein. See Miami -Dade County full disclaimer and User Agreement at http: / /www.miamidade.gov /info /disclaimer.asp. Property information inquiries, comments, and suggestions email: pawebmail @miamidade.gov GIS inquiries, comments, and suggestions email: gis @miamidade.gov Generated on: Tuesday, March 05, 2013 f 0110110 INC. A Construction Company License # (CBC1251654) (305) 685-0412 (Off) 14040 NW eh Coon (305)688-9550 (Fax) North Miami, Florida 33168 CONSTRUCTION AGREEMENT CUSTOMER: Mr. and Mrs. Rivera ADDRESS: 10255 Biscayne Blvd. CITY, STATE, ZIP: Miami Shores, Fl. 33138 PHONE: (305) 799.0935 DATE: December 5, 2011 ORONI, Inc. (hereinafter "ORONI"), for and in consideration of the prices herein named, proposes to furnish the work, and/or materials hereinafter described, subject to the conditions below, for the exclusive consideration of Mr. and Mrs. Rivera (hereinafter "CUSTOMER"). SCOPE OF W0RK Biock up garage Remodeling work for two doctor's offices 44111i....ILA': .11'! :11.41:00. EPA's Renovation, Repair and Painting Final Rule (40 CFR 745) requires that renovation conducted for compensation on pre-1978 homes and child occupied facilities, must be performed by a Firm that has been certified to meet all the requirements in 40 CFR 745.90. Test to determine the presence of lead in this property is not included in the estimate, if it is determined that lead is present, an additional estimate with additional charges will be presented to the customer for approval. eL, '11.1111. lierigna.311114:1#A1:1Wqr10,112111104iir:413112 I. Provide all product control approvals under Oroni's scope of work if available. 2. Owner to pay for surveys, permit fees, county fees. HRS fees and any special test required by building officials. 3. Provide all necessary, license and insurance to the building officials for approval fer IMINEE11.7 :21;.:/,:c;:;041frt, 4. Remove existing garage door and motor. 5. Remove all needed electrical fixtures. 6. Clean up and haul away all construction debris. k 4FAig,mr74.,4%vig, ,aOatziala t • 11111113;t1111117,11410% 7. Draw a sketch to be presented for permit. 8. Build columns and install blocks. 9. Stucco blocks on the outside. 10. Furry, insulation and drywall for inside. 11. Provide and install one impact resistance PGT exterior door. 12. Build up wood floor to match existing. 13. Provide two outlets and two switches for new area. - 14. Build one partition for sewing room. 15. Provide and install one new wall fan. 16. Paint old garage area to match existing. (paint provided by customer) Tr' , UttgaMPA 17. Permit fees, HRS processing of permits, city and county fees of any kind, 18. Architectural/engineer services of any kind. 19. Fixtures (i.e. faucets, tiles, tub, sink, lamps, etc.). 20. Landscaping/irrigation work of any kind. Customer understands that existing surrounding landscape and irrigation may be damaged during construction and Customer releases contractor for damages unless is caused by gross negligence. 21. Insulation in interior walls or partitions. 22. Door hardware 23. Low voltage wiring. 24. Plastering complete walls to avoid seeing patches. 25. Mold remediation. 26. Lead residual removal or remediation. 27. Removal of any support columns, walls or beams unless is specified in plans. 28. Asbestos test or special tests required by building officials. 29. Any other work not specified in this agreement. tit° ',#„„„ ':*, 30. 5% 31. 20% 32. 40% 33. 20% 34. 1 0% 35. 5% zp,Anitz.16.0.01101Itigir at signing at start after blocks are up after electrical rough inspection after compound is applied after painting AzAlaidkiZo AMMO 41111321r63PIR AteaLflt&L.,.,i 36. Contractor to maintain a working crew at job site during normal working hours (8-4:30 PM) unless weather, inspections, plan revision or other circumstances will not allow it. 37. Work will be supervised by one oldie Oroni's supervisors on a daily basis 38. Customer understands that this agreement and its terms and conditions supersede those found in the architectural drawings and general notes sections. This agreement is the only legal document for work contracted with ORONI INC. No verbal agreement will be binding or enforceable. 39. Approximate time for completion not counting permit processing or inspections is 45 days, 40. Price valid for 30 days. , • liggligliK.tomillitilt Sa.:42 .14;* 41. Customer shall be responsible for costs incurred for any and all special tests and/or inspections required by architect/engineer and/or building officials, 42. ORONI shall be responsible for scheduling all inspections with the local building and zoning departments. 43. Tile installation. If included in scope of work, Contractor will install ceramic tiles in square lay out (stan4,144), does not include glass tile installation, special borders, inserts, marble, ite, stone or any other type of material unless it is specified. 44. This agreement does not includes any low voltage wiring of any kind to include but not limited to TV, Alarms, Computers, Sound systems, Telephone etc. unless specified in this contract. 45. Repairs. Customer understands and agrees that in case of repair of tile. marble, stone, stucco, drywall, wood etc. repair material will be chosen by customer. Contractor is not responsible for matching surfaces> 46. Customer understands and ees that during the time that ORONI is providing permit and insurance for the project under this agreement, there will be no other work performed by any other worker not covered by ORONI's insurance unless a previous written agreement exists. If it is agreed that owner will hire someone else during the time ORONI's permit is open, customer agrees to pay 15% of total amount paid to such company for coordination purpose only. Company hired by owner must be licensed, have liability and worker's compensation insurance. ORON1 will not be responsible for quality or duration of such work. 47. ORONI is not responsible for the condition of the remaining structural members, 48. Customer is responsible for the purchase of all plumbing and electrical fixtures. ceramic tiles, bathroom accessories, shelving and/or hardware unless otherwise stipulated in contract> Contractor shall provide installation of all fixtures as noted in contract. 49. This contract does not include the cost to purchase or install cabinetry. flooring, and hardware for doors, window treatment, landscaping or irrigation unless otherwise specified in contract. This contract does not include any sidewalk, driveways repairs and/or replacement or chimney work unless otherwise specified. Damages to sidewalk or driveways during construction work shall be repaired at customer's expense. 50. ORONI shall keep the premises and surrounding area free from accumulation of waste materials or rubbish caused by operations under the contract. At completion of work, ORONI shall remove from and ut the project waste materials, rubbish, tools, and construction equipment, machinery and surplus materials. Sand, small paint chips, and other minor debris may remain behind; however, ORONI shall take measures to assure that the majority of the debris for construction described in this agreement is hauled away. 51. ORONI shall perform all work according to standard practices within the Florida construction industry as is consistent with the surrounding area and properties. ORONI shall comply with all manufacturer specifications and Dade County Product Controls. All wieners of construction performance shall he in accordance with the criteria contained in the current edition on the "National Association of Home Builders" (HAHB) publication. Residential Construction Performance Guidelines (RCPG). Prior to initiating any legal action or alternative dispute resolution proceedings, the parties shall consult the provisions found in the RCPG, and agree to resolve alt applicable construction performance questions or dispute in accordance with said provision. The RCPG shall be the standard of construction under the contract, and binding as to the determination of arty issues between the parties involving construction defect, quality, tolerances, appearance or condition of any proceeding brought in arbitration or before a court of law. The owner was informed that both Contractor and Consumer versions of Residential Construction Performance Guidelines are available at www.BuilderBooks,com or by cant 00-223- 2685. 52. Claims for consequential damages: ORONI and the Customer waive claim against each other for consequential damages arising out of or relating to this contract. This mutual waiver includes but is not limited to: rental, loss of use. income, profit, financing, business and reputation, loss of management or employee productiviry, services of such persons, contractor's principle office expenses, business reputation, toss of profit. etc. 53. MEDIATION. In the event a dispute shall arise between the parties to this contract, the parties agree to participate in at least four hours of mediation in accordance with the Construction Industry Mediation Rules of the American Arbitration Association currently in effect. The parties agree to share equally in the costs of the mediation. Mediation involves each side of a dispute sitting down with an impartial person, the mediator, to attempt to reach a voluntary settlement. Mediation involves no formal court procedures or rules of evidence, and the mediator does not have the power to render a binding decision or fore an agteetnt on the parties. 54. ARBITRATION. lfa dispute is not resolved through mediation, the parties will submit. to binding arbitration to address any controversy or claim arising out of. or relating to this contract or relating to any change orders or other changes or addendums to this contract. The arbitration shall be conducted by and according to the rules and procedures of the Construction Industry Arbitration Rules of the American Arbitration Association currently in effect, The Arbitration Award shall be binding upon the parties and shall be enforceable in any court of competent jurisdiction. Both parties shall share the cost of the dispute resolution process equally although personal attorneys and witnesses or specialists are the direct responsibility of each party and their fees and expenses shall be the responsibility of the individual parties. 55. This agreement covers only the work specified herein and does not cover any additional repairs which are found to be necessary subsequent to the commencement of the project. Any alteration or deviation from the specifications contained in this agreement, resulting in any additional cost(s) not anticipated herein, shall be deemed the financial responsibility of the Customer and shall be charged in addition to the amount of this cement. 56. ORONI is licensed and insured as required by Florida law. Notwithstanding said coverage, ORONi shall not be held responsible for any damages caused by acts of God or any other circumstances beyond its control Customer has the right to request a copy of said license and insurance from ORON1. 57. ORONI is not responsible for the condition of any existing equipment or fixtures. Ali equipment and fixtures that are to be installed by ORONI shall be standard. Non-standard fixtures and equipment (manufactured outside of U.S.A.) Shall be installed for an additional charge. 58. If work performed includes removing part or whole roof, Customer understands and agrees that in case of rain, storm, hurricane or any other acts of God, C)RONI shall not be held responsible for damages caused by such acts to include, but not limited to, furniture, appliances, art work, flooring, walls or ceilings or any other surface or item. However, ORONI will cover work area to the best of its ability. 59. ORONI is not responsible for damages to existing sod, grass, trees, sprinklers, water and sewer lines, septic tank, drain fields, power lines, telephone lines, cable lines. gas lines. driveways and sidewalks due to construction work on Customer's property. 60. All workmanship is warranted for a period of (1) year, Flat roofs (5) years and sloped roofs (7) years. This warranty may become void due to negligence or mistreatment by Customer or by making any alteration/repairs by any other person not working under Oroni Inc. guidance. Warranty shall only be honored when payment under this agreement and any related additional - charges are remitted in full. Warranty is not transferrable unless specified. 61. Customer understands that he/she has certain rights under the construction industries recovery fund. Customer has received a copy of the - Notice of Consumer Rights under the Construction industries Recovery Fund ". 62. Time limits on claims: Claims by either party (except claims for money owed to Oroni Inc.) must be initiated 21 days after occurrence of the event giving rise to such claim. Claims must be initiated by written notice to the architect and the other party. Before initiating any claim, Customer must allow ORONt the opportunity to correct the situation. 63. Matching of surfaces: Whenever matching a surface it shall be as close as possible considering availability of product and labor. If matching of paint, Customer sha.il provide ORONI with paint color. ORONI does not guarantee exact matches. ORONI is not responsible for patching of wood floors unless otherwise stipulated in this agreement. 64. Change Orders: Any additional work requested by customer verbally or written to employees, subcontractors or supervisors of Oroni Inc, or any additional work requested by building officials or architects, shall be considered an "additional work authorization ". Such additional work shall be paid' in full before work is performed. 65. Customer will pay for portable toilet in job site. If due to contractor's fault, project is delayed, contractor to Ray for the additional time portable toilet is on site. 66. If at any time the job is stopped for a period of time that causes the permits to expire, party responsible for delays will pay for permit renewal and any other cost involved. 67. ORON1 is not required to ascertain that the architectural drawings are in accordance with applicable law statues, ordinances, building codes or rules and regulations. ORON1 shall perform no portion of the work far which this agreement and its documents require submittal and review of shop drawings. product data, samples or similar submittals until the respective submittal has been approved by the architect. The architect of record may perform periodic visits to the job site (at Customers discretion) in order to insure and to keep owner informed about the progress and quality of the portion of the work completed, to determine in general if the work is being performed in a manner indicating that the work, when fully completed will be in accordance with the contract documents, and to determine the date or dates of substantial completion, wilt receive and t sward to the owner. for the owner's review and records. written warranties and related documents required by the contract and assembled tdibya°ROM, and its will issue a final certificate for payment upon compliance with the req is uments, however, the architect of record will not be required to make exhaustive or continuous on site inspections to check the quality or quantity of the work. The architect of record will neither have control over or charge of nor be responsible for the construction means, methods, techniques. sequences or procedures, or for the safety precautions and programs in connection with the work. These issues are solely ORONI's rights and responsibilities under this agreement. 69. The term "day " as used in this agreement and its documents shall mean working day unless otherwise specifically defined, At this stage of the project, the work or designated portion thereof is sufficiently complete in accordance with this t a eement and its documents so dint the Customer can occupy or utitize the areas for their intended use. However, the Customer may occupy or use any completed portion of the work areas only when such portion is determined by ORON1 and iocal building authorities to be in compliance with codes, rules and regulations appropriate for residing or use of said areas. 70. Customer understands that in the cases where stucco is applied, ORONI does not guarantee matching or a specific stereo thickness even though it may be specified on the architectural drawings. 71. Customer a. to allow ORON1 to use pictures related to this project for advertising purposes on their web a e w. ww`OR(Nl.coni} without prior consent or approval. 72. Customer should seek advice of an attorney before signing this agreement. ORONI hereby pro poses to furnish and labor - complete according to the above s ears ttions for the sum of 17,630.00 (Seventeen Thousand Six Hundred Thirty A Date ORONI, ittc.