Loading...
RCRT-11-2362E Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING Permit No. uT PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): Address: i City: State: Tenant/Lessee Name: Phone#: Email: JOB City: Folio) Is the Building Historically Designated: Yes CONTRACTOR: Company Name: Address: City: State: Qualifier Name: State Certification or Registration #: NO Flood Zone: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Certificate of Competency #: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration ❑New ❑Repair/Replace ❑Demolition Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO/CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip F Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value. exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of , 20 _, by Contractor The foregoing instrument was acknowledged before me this day of , 20 _, by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: My Commission Expires: APPROVED BY / Plans Examiner Zoning Structural Review (Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) Property Information Map Page 1 of 1 My Home Miami -Dade County, Florida MIAMI•QA�E Property Information Map Aerial Photography - 2009 0 - 79 ft This map was created on 12/23/20119:16:36 AM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. �105e Summary Details: Folio No.: 11-3206-011-0051 Property: 9031 BISCAYNE BLVD Mailing SHORE SQUARE Address: INVESTMENTS LLC Floors: 3850 BIRD ROAD STE 800 Living Units: MIAMI FL d' Sq Footage: 33146 - Property Information: Primary Zone: 200 ARTERIAL $1,394,008$1,394,00 BUSINESS CLUC: 0011 RETAIL OUTLET Beds/Baths: /0 Floors: 1 Living Units: 0 d' Sq Footage: 47,749 Lot Size: 2.90 ACRES Year Built: 1962 County: 53 42 ASBURY PARK $0/ PB 4-110 BEG 30FTW $3,358,109 OF SE COR LOT 5 RUN Legal 272.08FT N177FT Description: 260.97FT TO E RAWL $3,358,109 BISC BLVD chool Board: NELY139.58FT $0/ 1 $3,385,485 E290.02FT N124.93FT E152.16FT ALG Assessment Information: Year: 2011 2010 Land Value: $1,394,008$1,394,00 Building Value: $1,964,101 $1,991,47 Market Value: $3,358,109 $3,385,485 Assessed Value: $3,358,109 $3,274,989 Taxable Value Information: Year: 2011 2010 $0 Applied Applied Taxing Authority: Exemption/ Exemption/ Taxable Taxable Value: Value: Regional: $0/ $3,358,109 $0/ $3,274,989 County: $0/ $0/ $3,358,109 $3,274,989 City: $0/ $0/ $3,358,109 $3,274,989 chool Board: $0/ $3,358,109 $0/ 1 $3,385,485 Sale Information: Sale Date: 11/2005 Sale Amount: $0 Sale O/R: 4432-4515 Sales Qualification Description: Sales which are disqualified as a result of examination of the deed View Additional Sales http://gisims2.miamidade.gov/myhome/printmap. asp?mapurl=http://gisims2.miamidade.g... 12/23/2011 MIAMI SHORES VILLAGE Building Department 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305-795-2204 Fax: 305-756-8972 12/23/2011 Certified Mail # 7011 0470 0000 8985 5478 Property located at: Address: 9031 BISCAYNE Boulevard Miami Shores, Florida, Permit Number: RCRT-12-11-2362 Folio # 11-3206-011-0051 Notice of Required Insnection/Certification Dear Owner: The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8-11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two -hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection/Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305-795-2204. Sincerely, r` � . . ... • . . D Ln For delivery information visit our website at www.usPS.COM Norman Bruhn, uilding Official Ln F � L USE 305-795-2204 Ir D" cc Postage $ O Ceri fled Fm C3 Postmark C Retum Receipt F� Here 17 (Ertdorsemerd Required) Restricted Delivery Fee ® {Ertdor�merd Required) r`- TotW Postage & Fees Sod To 011 C3 u�fi � Apt N a PO Box No. � ----- -- a ---' d . -' '- '-- PS Form :rr August 2006 1. . 40Year.com, Inc., Engineers Professional Building Recertification & Due -Diligence Inspections Florida CA 9868 K1,K,4n JUL 14 2014 Miami Shores Village Building Department 10050 NE 2 Ave Miami Shores Village FL 33138 March 24, 2014 RE: Recertification of Buildings — 40 Years Old or Older Record Owner SHORE SQUARE PROPERTIES LLC Property Address 9031 BISCAYNE BLVD Folio # 11-3206-011-0051 Dear Sirs: This letter shall serve to transmit the attached "MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING'S STRUCTURAL & ELECTRICAL RECERTIFICATION" for the above referenced address 4kch will provide an itemized description of the condition of the various components. This inspection was completed on February 28, 2014. I hereby certify this building as being structurally and electrically safe for continued use and operation. As a routine matter, in order to avoid any possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure or electrical system. To the best of my knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent reasonably possible. No warranty is either expressed or implied. ReSpecftly;- u r o J cJ f. e° Marc O Touze, P.E. 40Year.corn, Inc. Brandon Shackelford 6731 SW 63 Court, Miami, Florida 33143 Telephone 305.665.2833 , Facsimile 305.665.2863 wwwAy ar.com Property Management & Maintenance, Inc. ■ Complets Items 1, 2, and 3. Also cgmplete Item 4 If Restricted Dslh►ery is desired' ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mallplece, or on the front If space permits. Addressed1. Arlicle V t1u Emilio Alvarez Property Manager Emilio.Alvarezeimcpropertymanagementcom 696 N.E. 125 Street North Miami, FL 33161 Tel: 305-893-9955 Ext:129 Cel: 305-305-2013 Fax: 305-899-9060 A. X 00— 0 A9erit _ o Addre !:Wt 1 K"�v D. Is degvery address diffeRM06m Item 11 0 Yes If YES, enter delivery address below 0 No SwAce TAM 13 Cernned Meq 13 Express Meq 13 Rem ❑ Return Receipt for Merchandise O Insured Mall ❑ C.O.D. l..ly1 CU JL , 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number 7011 0470 0000 8985 5478 (rransferfrom serv/Ce kW DomestlC Return Receipt 102595-02-M-1540 PS Form 3811, February 2004 MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING'S STRUCTURAL RECERTIFICATION INSPECTION COMMENCED INSPECTION MADE BY: DATE: F e[-)ruar 14, '22012 SIGNATURE AjAb- INSPECTION COMPLETED PRINT NAME Marc T " DATE: Fe-bruary "-:5,201,14 TITLE: Professional Engineer RE # 59525 ADDRESS: 0731 S1JV 63 Court Soutri Miami, FL 33143 9. Description of Structure a. Name of Title: ),LIARC PROPERTIES LLC b. Street Address: -,`, NE BLVD c. Legal Description: = URY PARK RB 4-110 BEG 30FT'VV L0T 5 RUN VV2" .03FT h9177FT TCa E RiVVIL BISC BLVD 1 FT E290,02FT N124.93FT ALG d. Owners Name: )IJARE PROPERTIES LLC-; e. Owner's Mailing Address: STREET f. Folio Number of Building: g. Building Code Occupancy 4 ,rCILIPS C & Nl Classification: h. Present Use: I rlss i. General Description, Type of Construction, Size, Number of Stories, Special Features, and Additional Comment: Gna adjusted. Three sections, north, C.erlt: a, a; SOLO h Of.affering configurations. Rectangular overall plan. Flat roof,,. a ad pay a,pe;'. ; �er section is higher elevation. Uniform overh,angi, across enure i`ront of bUil� h .)Edestrian walkway and has sloped tile roof prc,jecting frc-lni -op of .',architectural fa;ade-faces extend aE-'eov the frcnla_ =vd a -)i me ove(h r+r -in above the high level of the overhang Additions to Original Structure: I1`,1ort) and scluih sa ii,.)n , rnva 9031 Biscvayne Blvd, 11-3206-011-0051 R1, Structural, Page 2 2. PRESENT CONDITION OF STRUCTURE a. General alignment (note good, fair, poor, explain if significant) 1. Bulging i`" P,c: J c l F_1ihorl 2. Settlement Go --'d 3. Defections 4. Expansion 5. Contraction b. Portion distressed (Note, beams, columns, structural walls, floors, roofs, other) Good condition c. Surface conditions - describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration & stains. r -e-.-, ,, dition d. Cracks - note location in significant members. Identify crack size as HAIRLINE if barely discernible; FINE if less than 1 mm in width: MEDIUM if between 1 and 2 mm in width; WIDE if over 2 mm. e. General extent of deterioration - cracking or spalling of concrete or masonry; oxidation of metals; rot or borer attack in wood. f. Previous patching or repairs g. Nature of present loading indicate residential, commercial, other; estimate magnitude. 3. INSPECTIONS a. Date of notice of required inspection b. Date(s) of actual inspection dark 14, 1`01 and February 28, 2014 c. Name and qualification of individual submitting inspection report r to T:_, i -ie, E 4 1: _ .. d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures: e. Structural repair note appropriate line: 1. None required 2. Required (describe and indicate acceptance) 4. SUPPORTING DATA a. ,IA sheet written data b. itia; photographs C. Nth drawings or sketches 9031 Biscvayne Blvd, 11-3206-011-0051 R1, Structural, Page 3 5. MASONRY BEARING WALL, Indicate good, fair, poor condition: a. Concrete masonry units Good condition b. Clay file or terra cotta units c. Reinforced concrete be columns Good condition d. Reinforced concrete fie beams Good condition e. Lintel f. Other type bond beams g. Masonry finishes - exterior 1. Stucco Good condition 2. Veneer 3. Paint only 4. Other(describe) h. Masonry finishes - interior 1. Vapor barrier 2. Furring and plaster 3. Paneling 4. Paint only 5. Other (describe) rd Good condition 6. Other (describe) Good condition i. Cracks: fAone observed 1. Location - note beams, columns, other 2. Descripfion j. Spalling: '�one observed 1. Location - note beams, columns, other 2. Description k. Rebar corrosion -check appropriate line: 1. None visible 2. Minor -patching will suffice 3. Significant -but patching will suffice 4. Significant -structural repairs required I. Samples chipped out for examination in spall areas: NA 1. No 2. Yes - describe color, texture, aggregate, quality 9031 Biscvayne Blvd, 11-3206-011-0051 R1, Structural, Page 4 6. FLOOR AND ROOF SYSTEM a. Roof: 1. Describe (flat, slope, type roofing, type roof deck, condition. Tat roof3 and ir�rrapel vv oll., ,r,t i-oofing in fair condition. Gypsum panel decks in tgt o+ ,'i c,;rditi n. 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and condition of support: 3. Note types of drains and scupper and condition: Gutters and :.:it rear in '- b. Floor systems(s) 1- Describe (type of system framing, material, spans, condition) rt``'rH s iah— cn gr:91'71e W; lam" -O 9 l -If i c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members. 7. STEEL FRAMING SYSTEM a. Description: C- S -tee; tIt)l1.arn s'!J`l_ , b. Exposed Steel - describe condition of paint & degree of corrosion: Good t�i�erlC�iCIL r1 c. Concrete or other fireproofing — note any cracking or spalling, and note where any covering was removed for inspection k ?I t',/tr 1 onJl!:1�3 �,.r i,'_ J' i � ja :IY - S d. Elevator sheave beams & connections, and machine floor beams — note condition: NA 9031 Biscvayne Blvd, 11-3206-011-0051 R1, Structural, Page 5 8. CONCRETE FRAMING SYSTEM a. Full description of structural system coIuIII F,S b. Cracking 1. Not significant 2. Location and description of members affected and type cracking c. General condition Good condition d. Rebar corrosion - check appropriate line: 1. Non visible ; 2. Location and description of members affected and type cracking 3. Significant but patching will suffice 4. Significant - structural repairs required (describe) e. Samples chipped out in spall areas: 1. No 2. Yes, describe color, texture, aggregate, general quality: 9. WINDOWS a. Type (Wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) b. Anchorage — type & condition of fasteners and latches: Cja�cC$ cr,ut��iiVc+9l c. Sealant — type of condition of perimeter sealant & at mullions: Good condi*non d. Interiors seals — type & condition at operable vents: e. General condition: �,�00d cc'Ficfii:4( T 10. WOOD FRAMING a. Type — fully describe if mill construction, fight construction, major spans, trusses; b. Metal fittings: angles, plates, bolts, split pintles, pintles, other, note condition: c. Joints — note if well fitted and still closed: W d. Drainage — note accumulations of moisture: e. Ventilation —note any concealed spaces not ventilated: ill f. Note any concealed spaces opened for inspection: < ° k1A k e Q a o» e» MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING'S ELECTRICAL RECERTIFICATION INSPECTION COMMENCED INSPECTION MADE BY: DATE: Febmary SIGNATURE INSPECTION COMPLETED PRINT NAME Kil-11C DATE: Febri,tary-08 "',01,1 TITLE: ProfcX neer PE # 59525 ADDRESS: 5731 SVV 63 Court South Miami. FL 33143 1. Description of Structure a. Name of Title: dJARE PROPERTIES LLC b. Street Address: ,YNE BLVD c. Legal Description: .,URYPARK P8 4-110 BEG 30FTV4 -78FT M177FT LOT 5 RUN W212.0 TO E RAN/L BISC BLVD !.)'FT E290.02FT N124.93FT 'ALG d. Owners Name: UARE PROPERTIES LLC e. Owner's Mailing Address: STREET f Folio Number of Building: g. Building Code Occupancy Groups 13,5, M Classification: h. Present Use: :Pi Fiess i. General Description, Type of Construction, Size, Number of Stories, Special Features, and Additional Comment: One s1crv, CBS, adjusted Three, sections: north, ever &-:r' &. south of-sallrla StFUCWrai d�-:-'� 1+lfering configurations. Rectangular overall plan Fat rools,:-tnd p-arapet,kf er section is higher elevation. Uniform overhang acrcllss en ire frcwit of buildi,-'oedestrian walkway.and has sloped file roof proiecting froni'z-.k,�)ve top of par ,architectural fai�ade-faces extend abo� e front edge jf the overhaf-10 in above the high level of the overhang roof Additions to Original Structure: [1orth and souih sedicjnrnay beaclk.:' 9031 Bisevayne Blvd, 11-3206-011-0051 R1, Electrical, Page 2 GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 1. ELECTRIC SERVICE 1. Size: Amperage Fuses X XX )Breakers xxx 2. Phase: 3-Phase(I-Phase XX X 3. Condition: Good X" Fair )Needs Repair Comments: 3'ulldlnc-- s� rvjc&- ral ai - -d South. Noi-,"h service -- (-)verhead servioe to 3X1000-1QJ)- breaker, rter ,,ault at grade to lectric room with 2 d i -sc-, o n t) e c t s o1 6 0 0 A - i} ,ad lauNat grade to electric room. 2. METER AND ELECTRIC ROOM 1. Clearances: Good ( Fair( Requires Correction Comments: 3. GUTTERS 1. Location: 2. Taps and Fill: Comments: 4. ELECTRICAL PANELS 1. Panel# Location: 2. Panel# Location: 3. Panel# Location: 4. Panel# Location: 5. Panel# ( ) Location: Comments: 5. BRANCH CIRCUITS 1. Identified: Yes 2. Conductors: Good Comments: Good( Requires Repair( Good( _XX Requires Repair( il ectl Jc root Good( X/XX ) Needs Repair( Aectric room Good( ) Needs Repair( 31 occupandes Good( X X X ) Needs Repair Good( ) Needs Repair( Good( "­X,X Deteriorated( 6. GROUNDING OF SERVICE Condition: Good: Comments: ) Needs Repair( Must be Identified ( ) Must Replace Repairs Required jo tu 9031 Biscvayne Blvd, 11-3208-011-0051 R1, Electrical, Page 3 7. GROUNDING OF EQUIPMENT Condition: Good: (::x'. ) Repairs Required ( ) Comments: 8. SERVICE CONDUITS/RACEWAYS Condition: Good: Comments: 9. SERVICE CONDUCTORS AND CABLES Condition: Good: Comments: 10. TYPES OF WIRING METHODS Condition: Conduit Raceways: Good: Conduit PVC: Good: NM Cable: Good: BX Cable: Good: { 11. FEEDER CONDUCTORS Condition: Good: ( : ;A ) Comments: 12. EMERGENCY LIGHTING Condition: Good: Comments: 13. BUILDING EGRESS ILLUMINATION Condition: Good: Comments: 14. FIRE ALARM SYSTEM Condition: Good: ( ) Comments: s',Id reC; U re', 15. SMOKE DETECTORS Condition: Good: ( ) Comments: H(, Repairs Required ( ) Repairs Required ( ) } Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( Repairs Required ( Repairs Required ( Repairs Required ( Repairs Required ( 16. EXIT LIGHTS Condition: Good: Comments: 9031 Biscvayne Blvd, 11-3206-011-0851 R1, Electrical, Page 4 X X. ) 17. EMERGENCY GENERATOR Condition: Good: ( ) Comments: r l [ u Repairs Required ( Repairs Required ( 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS Condition: Good: ( ) Repairs Required Comments: 19. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING Condition: Good: ( Y':''. ) Repairs Required Comments: Pa-�J g iiigf ate ti -j rineet. C.(- ,_a �I �� IV9i���ri-Dade Code. 20. SWIMMING POOL WIRING Condition: Good: ( ) Comments: 21. WIRING OF MECHANICAL EQUIPMENT Condition: Good: Comments: 22. General Additional Comments None Repairs Required ( Repairs Required ( } 6 ,I. 'tea: 4:•. ,qy� n p a`GC �O �F_ CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS REQUIRMENTS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY March 25, 2014 Re: Folio No. Property Address Building Description (IAE BLVI '-"�stri.,ictui,e.Apprcx.'8,148sci.ft. sections: north, center. & south of -al ci.esion and differing configurations. - -.aVerall plan. Fiat roofs and parapet section is higher elevation. Uniform c,,,, oss entire front of building covers aikvvay and has sloped the roof -apet. Two n above top of pai acadr.-faces extend above the front I ec verhang to elevation above the high le,,.,;; ,erhang roo�' The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On, FebrL13! Y 2-8, _20-14 I inspected the parking lot(s) servicing the above referenced building for compliance with Section 8C-6 and determined the following (check only one): XThe parking lot(s) is not adjacent to or abutting a canal, lake or other body of water. 0 The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section EIC -6 of the Miami -Dade County Code. 0 The parking lot(s) is adjacent to or abutting a canal, lake or other body of r n parked vehicles are not protected by a guardrail that complies with Se - Miami -Dade County Code. I have advised the property owner that h t 11 in a permit for the installation of the guardrail and obtain all required in rro S no later than April 10, 2014 CC. (SIAiturd) Marc 0 Touze, Pt (Print Name) Seal of Architect or Engineer Executing the Certification must be affixed in the Above Space I CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MD MI-DADE COUNTY March 25, 2014 Re: Folio No. Property Address Building Description The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. 2. On, Ferro ary 2'8, 2014. 1 measured the level of illumination in the parking lot(s) serving the above referenced building. 3. The level of illumination provided in the parking lot(s) meets the minimum standards. for the occupancy classification of the building as established in Sectioh- '' _ _ structure. Approx. 38,148 sq. ft. Code of Miami -Dade County. -ee sections: north, (.-enter. & south of e. r al design and differing configurations. overall plan. Flat roofs and parapet a,� e,dtion is higher elevation. Uniform za�F 1JJ) -OSS entire front of building covers ;alkway and has sloped the roof _r;I'_ - , ,nn above top of parapet. Two ;made -faces extend above the front E d ;i . � � lverhang to elevation above the high le�, r;' r verhang roof. The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. 2. On, Ferro ary 2'8, 2014. 1 measured the level of illumination in the parking lot(s) serving the above referenced building. 3. The level of illumination provided in the parking lot(s) meets the minimum standards. for the occupancy classification of the building as established in Sectioh- '' f the ' a Code of Miami -Dade County. r ® Marc O Touze; (Print (Va'e­ Seal of Architect or Engineer Executing the Certification must be affixed in the Above Space