Loading...
RF-14-146Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami.Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 206213 Permit Number: RF -1 -14 -146 Scheduled Inspection Date: March 27, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection', Type: Final Roof Owner: PADILLA, FERNANDO & MARTHA Work Classification: Flat Job Address: 365 GRAND CONCOURSE Miami Shores, FL Phone Number (786)269 -8313 Parcel Number 1132060135950 Project: <NONE> i Contractor: DALEY ROOFING INC Phone: (305)754 -9892 Building Department Comments Infractio Passed Comments RE- ROOF FLAT ROOF INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- Inspection fee is paid. March 26, 2014 For Inspections please call: (305)762 -4949 Page 5 of 28 Miami Shores Village L Building Department JAN 18 20% 90050 N.E.2nd Avenue, Mami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BY' INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDING FBC 20 Permit No. I Master Permit No.�) IG.�" `L'6 " 1 � 6 r City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple City: Tenant/Ussee Name: Phone #: Email: CONTRACTOR: "Company Name: ���� � �%I � . lTfi � Phone#: Address: 1^ 1► I 10 to I1 City: 9 Zip: _3 Qualifier Name: i C-" -' vu, State Certification or Registration #: 7 VQ o Contact Phone#: Email Address: of Competency #: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $-46 Et, • u s 4 d , oo sge of�l"ptk: 10 f Type of Work: ❑Addition OAlte on; �. J, 9 10 '` p ' eplac ODemolition Description of.Work: a Colon thru tile: Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Educadon Fee $ Double Fee $ Structural Review $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DUE $ �� Bonding Company's-'Naine'(if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature L-- Signature ba.� ° Owner or Agent The foregoing instrument was acknowledged before me this day of ; R Una , 20 tiW , by f ti'nas, It 9CtA;W0-- , who is personally known to me or who has produced q D4— i U) • 9-Aa •lot ° 35i• a As identification and who did take an oath. Contractor The foregoing instrument was acknowledged before me thisi g day of -Yw v a , 20 !—L4-, by Qr l a ` Ca, Ig=-M who is personally known to me or who has produced-0-9 06 17,tT-`6L1 ZA� as identification and who did take an oath. NOTARY PUBLIC: LIC: �• WAE FIGUEROA Sign: Ma Notary PnaJ Florida Print: 1 t ` I"�-G� i�lfi9�. -. ¢o•• Cafss'�'i�� My Commission Expires: tk�-ecd, 3� yo 1'1— My Commissi ry • �"' Joanna M Feliciano F►orldlj ,�` A9y Commission FF 082783 Facplrea 01/12/201a gabd= 4aksR���a�& �ksk,k9Q�ua�ak4�d,8s�,R����IaAs ��k�sk$ �An�k, �k/ nA$ ��k�, ksH$ aW�sdak�+ Is�t+ Q��d «Ak�Ka�a,kak,Rak�ak0.�sk�k�#� ,k � deek4hsP�A�� sksl APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 3 /1212012)(Revised 07 /10/07)(Revised 06AW 09)(Revised 3115/09) X T, - AAWSW*6 I-U rl jAmponwhe in �IIW I- 7,7 -75 4 a I X11� "MIROMP-M-3 rAft md SWAIMM tee c ovum �1� flamm"BrAlum At'affemium Aum Ihmodk- Ab HK�WVRLOCITY HURRICANE ZONES Florida Building Coda Edition 2010 Hlah Velocky Hurricane Zone Uniform Permit 6WHcation Form. Section G (Low slope Application) Fill in Specific Roof Assembly Components Fastener Spacing forAnchor/Base Sheet and Identify Manufacturer Attachment (if a component Is not used, identify as `NA") Field; �° oc Lop, #Rows oc System Manufacdurer. � 11 Perimeter: b—° oc a L•ap, # Rows 0 _° 0 Comer —&' oc 0 Lap, # Rows q @ _° oc Design. Wind Pressures, From RAS 128 or Ca`IWations; P2 � P3; 3%� 7 Number of Fasteners Per insulation P1; � Board Max. Design Pressure, From the Spektic OA Field Perimeter Corner System: 2 Deck: 9 Type: / Gauge(Nckness: Slope: r4 AT Anchor/Base Sheet & No. of Ply(s): AnchoriBase Sheet Fastener/Sonding Material: Insulation Base Layer Base: Insulation Size and Base Insulation Fastending Material: Top Insulado yer: Top Ins Lion Size and Thlc)aiess: T :Insulation FastenerBonding Material: Base Sheet(s) & No. of Ply(s):_ ' L7 #'5. Illustrate Components Noted and Details as Applicable: Woodbtocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Caret Strip, Base Flashing, Counter- Flashing, Coping, Etc. gi Indicate: Mean . Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material. Thickness, fastener Type, Fastener Spacing or Submit Manufacturers retails that Comply with RAS 111 and Chapter 16. FT. q, �' Parapet Heiaht ®r f!iy Roof Ply Sheet(s),& No. of Ply(s): Wa � M a Height Ply Sheet Fastener/&mding Material:4 15 Top Ply:: N U DI A 0- 21 CH&WME 1-70f4- �► ®� �� Top Ply Fastener / Bonding llr wao Surfadng: U a- Or 4 Miami Shores Village' Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: aD L Property Roofing Permit Number. cz) n Dear Building Official: I fUAAt& �'� certify that I am not required to retrofit the roof to wall connections of my building because: "e just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. 4' Sworn to and subscribed before me this '1,4" day of 70 t4 Notary Public, Sate of Florida at Large • When the just valuation of the structure fo purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane M'iti'gation. Revised on 5@112009 FLORIDA JURAT FS 117.06 /,•�,_: K• .: ". W,:lt!rv::'.171\t/17N,,. _:1va ..\ . It w3!aclti .�k. ,:..:. .� :r.�Y�r s .lv�.�. %i�.��. . ra ::�t!c�t ,!c��Cc Ica, �. rteYM✓.:�e State of Florida County of MA, ���-� -- Sworn to (or affirmed) and subscribed before me this (9 4 day of -Jr- n u crr 7"011 Day Month Year OPTIONAL Though this section is optional, completing this information can deter alteration of the document or fraudulent reattachment of this form to an unintended document. Description of Attached Document Title or Type of Document: ® lob n e- rj A -F . � v ` D C pe M ` 0 n Document Date: Number of Pages: Signers) Other Than Named Above: N o O4,e -r S;C n c1LS 0 2013 National Notary Association • www.NationaiNotary.org • 1- 800 -US NOTARY (1- 800 - 876 -6827) Item #5186 by 1'e—r nor, ao Pow i 1\0, Name of Perso acing or Affirming MARIE FIGUEROA ? Notary Public . State of Florida ;• ply CWM. Es om Mar 3, 2017 •• '••;;nF Com�iselon # EE 879484 Si natu a of Not P lic 9 Notary — State of Florida n.°t•`o, Name of Notary Typed, Mnted or Stamped ❑ Personally Known ofn Produced Identification Type of Identification Produced: �±(( \ l Place Notary Seal Stamp Above CS40- 2 -t0 - G i 3,39-0 OPTIONAL Though this section is optional, completing this information can deter alteration of the document or fraudulent reattachment of this form to an unintended document. Description of Attached Document Title or Type of Document: ® lob n e- rj A -F . � v ` D C pe M ` 0 n Document Date: Number of Pages: Signers) Other Than Named Above: N o O4,e -r S;C n c1LS 0 2013 National Notary Association • www.NationaiNotary.org • 1- 800 -US NOTARY (1- 800 - 876 -6827) Item #5186 MM7 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. `� Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. !g Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. —!L—Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. �J Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. & ±� Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. t! Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. - �F� " I 24 ( 1tA Owner /Agents Signature Date Revised on 7/9/2009 LD 1:2711 Contractor Signature Da MIAMNDiADE MIAMI -DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315 -2590 F (786) 31525 -99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov /economy GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF RuberoteModifted Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09 -0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 1 of 29 Membrane Type: APP /SBS Heat Weld Deck Type 1: Wood, Non - insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating, VersaShielde Fire - Resistant Roof Deck (optional) Protection or SecurocV Gypsum -Fiber Roof Board. Base sheet: GAFGLAS® #80 Ultima"" Base Sheet, GAFGLAS® Stratavente Eliminator Nailable Venting Base Sheet, Ruberoide Mop Smooth, Ruberoide 20, Ruberoid® SBS Heat - Weld' Smooth or Ruberoid® SBS Heat - Weld's 25 mechanically fastened to deck as described below; Fastening Options: GAFGLASe Ply 4, GAFGLAS® F1exPly"m 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS F1exPly"' 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Tecm #12 Fastener, Drill -Tec"m #14 Fastener or Drill-Tec." XHD Fastener and Drill-Tec"` 3" Steel Plate, Drill - TecT" AccuTrace Flat Plate or Drill -Teem AccuTrae Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® FlexPly 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. _(Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 Ultima Base Sheets, Ruberoide' 20,, Ruberoid Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill - Teel" #12 Fastener, Drill -Tec' #14 Fastener or Drill -Tec.' XHD Fastener and Drill -Tec"" 3" Steel Plate, Drill- Teo" AccuTrace Flat Plate or Drill -Teem AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 13-0424.14 NugM�.pppE UN7Y Expiration late: 11/06/14 JAPPROVEDI Approval Date: 10/31/13 Page 27 of 29 Any of above base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLASO #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec"' #12 Fastener, Drill -Tec"' #14 Fastener or Drill -Tec'4 XHD Fastener and Drill -Tec' 3" Steel Plate, Drill -TWm AccuTrace Flat Plate or Drill- Tec'' AccuTrae Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional except over Ruberoid® Mop Smooth, Ruberoid® 20, Ruberoid® SBS Heat - Weld's Smooth or Ruberoid' SBS Heat - Weld's 25) One or more plies GAFGLAS® Ply 4 or GAFGLAS® F1exPly 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. or Ruberoid® Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of Ruberoid Torch Smooth, Ruberoid® Torch Granule, RoofMatchm APP Modified Granular, Ruberoid® EnergyCapTm Torch Granule FR, Ruberoid® EnergyCap - Torch Plus FR, or Ruberoid® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid® SBS Heat - Weld" Plus, Ruberoid® SBS Heat - Weld Plus FR, Ruberoid® SBS Heat - Weld" 170 FR, Ruberoid® EnergyCap'm SBS Heat - Weld° Plus FR, Ruberoid® SBS Heat - Weld's Granule, Ruberoid® SBS Heat -Weld' Smooth and Ruberoid® SBS Heat - Weld'' 25 applied according to manufacturer's application instructions. Surfacingi Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 601bs. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCap"" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. 3. Topcoat® Elastomeric Roofing Membrane, Topcoat' MB Plus (to be used as a primer with Topcoat® Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal. /sq. Maximum Design Pressure: See Fastening Above NOA No.: 13- 0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 28 of 29 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® F1exPly m 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1 /a" DensDecV Roof Board or '/2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL, LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is speciflcally referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 29 of 29 Base Sheet: — One ply "LlbertyTm SBS Self - Adhering Base /Ply Sheet" or "LibeltyT" SA Base /Ply Sheet ", self - adhered. Membrane: "Ruberoid@ Torch FR" or "Ruberoid@ SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" or "Ruberoid@ Torch Plus FR ". 64. Deck: C -15/32 Incline: 1/2 Base Sheet: — Two plies Type G2 or "GAFGLASO #75 Base Sheet ", or "Ruberoid@ 20" or "Ruberoid® 20 HT" or "Ruberold@ Dual Smooth" fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 or Type G2 or "Ruberoid® SBS Heat Weld Smooth." Membrane: — 'Ruberoid@ SBS Heat Weld 170 FR" or "Ruberoid@ SBS Heat Weld Plus FR" heat fused 65. Deck: NC Incline: 1/4 Insulation (Optional): — Polylsocyanurate, wood fiber, glass fiber or perlite mechanically fastened, any combination, any thickness. Base Sheet: — One ply "Ruberoid@ SA Base /Ply Sheet" self - adhered Membrane: — One ply "Ruberoid@ SA Cap FR" self- adhered 66. Deck: C -15/32 Incline: 1/2 Insulation (Optional), — Any thickness perlite, glass fiber, polyisocyanurate, perlite /polyisocyanu rate composite, mechanically fastened or adhered with any UL Classified insulation adhesive. Barrier Board (Not required when the roof deck Is noncombustible): — Minimum 1 /4 -in. thick Georgia - Pacific Gypsum LLC "DensDeck @ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'''P° Roofboard" or United States Gypsum Corp. "SECUROCKO Roof Board" (Type FRX -G) or "SECUROCKO Glass -Mat Roof Board" (Type SGMRX) Wth butt joints In the barrier board staggered a minimum of 6 -in. from butt joints in plywood roof deck Base Sheet: — Two plies Type G2 "GAFGLAS #75 Base Sheet" fully adhered with hot roofing asphalt. Ply Sheet: — Two plies Type GI "GAFGLAS Ply 6" fully adhered with hot roofing asphalt. Membrane: — One ply "Ruberoid@ EnergyCapT" Dual FR" fully adhered with hot roofing asphalt 67. Deck: C -15/32 Incline: 1h Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered Wth OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Barrier Board: — Minimum 1 /4 -in. thick Georgia - Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardT" Roofboard" or minimum 1 /4 -In. thick Untied States Gypsum Corp. "SECUROCKO Roof Board" (Type FRX -G) or "SECUROCKO Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -in. from plywood deck joints. Base Sheet: — One or more plies Type G2 "GAFGLASO *75 Base Sheet" or "Tri -PlyO *75 Base Sheet" or Type G1 or Type G2 fully adhered with hot roofing asphalt or mechanically fastened Ply Sheet: — One or more piles "Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Dual Smooth" fully adhered with hot roofing asphalt or mechanically fastened Membrane: — One ply "Ruberoid@ 30" fully adhered with hot roofing asphalt. Surfacing (Optional): — " TOPCOAT@ EnergyCoteT" Elastomeric Coating" or "TOPCOAT@ MB Plus" applied at a rate of 2- gal /100 -ft2. 68. Deck: NC Incline: 1/2 Primer (Optional): — One application "TOPCOAT@ Surface Seal SB" applied at 1 -gal /100 -ft2 . Insulation (Optional): — Perllte, fiber glass, polyisocyanurate, urethane or perlite /polylsocyanurate composite. Base Sheet: — One or more layers "GAF Stratavent@ Eliminator'" Venting Base Sheet (Perforated)" or "GAF Stratavent@ Eliminator'" Venting Base Sheet (Nailable) ", Type G2 "GAFGLASO *75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place. Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberold@ Dual FR" or "Ruberoid@ Mop FR" or "Ruberoid@ EnergyCapT" Mop FR. 69. Deck: NC Incline: 1/2 Base Sheet: — One ply of "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Dual Smooth" fully adhered with "Matrix'"" 101 Premium SBS Membrane Adhesive" applied at a rate of 1-1/2 - gal /100 -ft2. Membrane: — One ply "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberoid@ Mop FR" or "Ruberoide EnergyCapT" Mop FR fully adhered with "Matrix T" 101 Premium SBS Membrane Adhesive" applied at a rate of 11/2- gal /100- ft2. 70. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Any thickness "EnergyGuardT" or "EnergyGuardT" RA" or "EnergyGuardT" RN" or "EnergyGuardT" RH" or "EnergyGuardT" RF" or "EnergyGuardTM Ultra" polyisocyanurate, mechanically fastened or adhered wrath OMG Inc. "OlyBondT" Fastening System" or any UL Classified Insulation adhesive. Barrier Board: — Minimum 1/4 -In. thick Georgia- Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardT" Roofboard" or minimum y4 -in. thick United States Gypsum Corp. "SECUROCKO Roof Board" (Type FRX -G) or "SECUROCKO Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -in. from plywood deck joints. Base Sheet: — One ply of "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Dual Smooth" fully adhered Wth "Matrix'" 101 Premium SBS Membrane Adhesive" applied at a rate of 11h-