Loading...
MCC-19-101Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: MCC-01-19-101 ftmI iGPermit Type: Mechanical -Commercial ork Classification: Fire Suppression System Permit Status: Approved Issue Date: 01/22/2019 I Expiration: 07/15/2019 Location Address Parcel Number 90SO BISCAYNE BLVD, Miami Shores, FL 33138 1132060100010 Contacts PUBLIX SUPERMARKETS, INC Owner PUBLIX SUPERMARKETS, INC Applicant PUBLIX SUPERMARKETS, INC PUBLIX SUPERMARKETS, INC P 0 BOX 407, LAKELAND, FL 338020407 P 0 BOX 407, LAKELAND, FL 338020407 Other:863688747 Other:863688747 S & L FIRE PROTECTION Contractor STANLEY KUNTZ 1614 N 29 AVE, HOLLYWOOD, FL 33020 Home: 9546654097 Description: RELOCATE FIRE SPRINKLER 18 HEADS MASTER FOR Valuation: $ 2,000.00 Inspection Requests: THIS PERMIT IS CC18-902 305-762-4949 Total Sq Feet: 791.00 Fees Amount Application Fee - Other $50.00 CCF $1.20 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.40 Permit Fee $50.00 Scanning Fee $9.00 Technology Fee $2.50 Total: $117.10 Payments Date Paid Amt Paid Total Fe $117.10 e CvF9Wtt :� 01/22/2019 $67.10 Check# 11537 01/15/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constru n nd zoning. Futhermor , authorze the above named contractor to do the work stated. Owner / Applicant / Contractor / Agent Date January22, 2019 Page 2 of 2 Miami Shore Village RECEIVED Building Department 1 112019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 % I Tel: (305) 795-2204 Fax: (305) 756-8972 q_1 INSPECTION LINE PHONE NUMBER: (305) 762-4949-�� FBC 20(-4 BUILDING Master Permit No. c C —.4 — / 9'' To z PERMIT APPLICATION Sub Permit No. I ' t Cc C ) ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP APAbV_ SoQ r(VK "Rgl$ CONTRACTOR DRAWINGS JOB ADDRESS: QO�o Rlsc�.-(w►� B��/f=. City: Miami Shores County: Miami Dade Zip: 'J3)3`b Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE::r FFE: OWNER: Name (Fee Simple Titleholder): P� kJvC _ Phone#: 0 63 69,,q' -74 7 Address: f S 60K 40-7 City: �Nc� State: Zip: 3 3 v ©2- 04 d -] Tenant/Lessee Name: Phone#: & (a 3 —629. -7 7 Email: CONTRACTOR: Company Name: 154-1— Fj%jr- �t�.csYic>j j Phone#: 3!-&&S=47 Address: RO. $oX 81—,44&7 City: State: Zip: 22a2ga/ Qualifier Name: K4-W- z_ Phone#: cl&f -<v6p' -4c � 7 State Certification or Registration #: 24>0 9 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: State: Zip: Value of Work for this Permit: $ 10 00 t.� Square/Linear Footage of Work: Type of Work: ❑ Addition r?K Alteration ❑ New ❑ Repair/Rep/lace El Demolition Description of Work: k O Gok 2 f � s Pl�(N 1L� / 9 Aa,Q (/ _ � Specify color of color thru the: Submittal Fee $ Scanning Fee $ Technology Fee $_ Structural Reviews $ (Revised02/24/2014) Permit Fee $ \ Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ O Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. , I A I i C Signature Signatu OWNER or AGENT The foregoing instrument was acknowledged before me this �— day of 20 tre1 by " \ Y�� �7 J who i personal) know o me or who has produced identification and who did take an oath. NOTARY t•.n• s tt jno \Q • The foregoing instrument was acknowledged before me this _?f day of 20 JIE�> by GJVA- 4 l4 ig-r.-1 L<"mX-C—z—who is ersonally known t as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: as Seal: Seal: rti MxyMYCOMMISSION#GG2B7786 ol...... DIANASHECKLER * r =?� o`. EXPIRES: October 15, 2022 Commisslnn # GG 230606 Oy"°` Bowed Thu Notary Pubk Wkwfts ,� Expires June 19, 2022 ***ssss ** ry **** k ** r *—% *****rr**************r********«******•r*****r*****r****** **.* APPROVED BYI ans Examiner Zoning Structural Review Clerk (Revised02/24/2014) f� gLCx q C)0 51 �-�4 NOTE: ALL SHEET MUST BE REVIEWED MIAMI-DADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way) • Miami, Florida 33175-2474 • (786) 315-2100 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE AND/OR DEPARMENT OF ENVIRONMENTAL RESOURCES MANAGEMENT 'PLLCh 1-1 lc 744 .... PROVIDE MUNICIPAL PROCESS NUMB R HERE • • • • • • • • • • aF Job Address IR0ISO b1�ac,taY�l� �U�.•�� Z Contractor No. Ow 09 Last four (4) digitseaf4 uoalifier No. O W Folio a a Contractor Name F: Lam. �resr� a o U� Lot Block � ¢ Zo Qualifier Name • • • LL&4T'e-� • o a Subdivision PBpg o U. v? Address�.0..' �C •mil e�•••�• City. Aot4mr g tate 1=i ip Metes and bounds [ New Construction on Land [ ]Demolish ,O ...... Current use of property .'TAT L✓ :.... lVacant [ ] Shell Only .. • • • 0 U. w [ ✓J Alteration Interior [ ] Addition Attached - •• - w W [ ] Alteration Exterior [ ] Addition Detached , Description of Work �- � '�' J8 N a 0 �a [ ] Relocation of Structure [ ] Re -Roof Sq. Ft. Units Floors a. [ ] Enclosure [ ] Foundation Only ( [ ]Repair [ ] Repair Due to Fire Value of Work�p% [ ] MELD' [ ] Chg. Contractor Owner Address 0. Category y F [ ] Re -Issue W a City State _Zip [ ] MELE N [ ] Re -Stamp U) [ ] MLPG w [ ] Revision w Phone Last four (4) digits of a [MEC [ Not Applicable for o [ FIRE � Fire Owner's Social Security No. z Name S�61O C4EC�2-�--> Owner z g w LU w Address to 101 Si,,) � l O CT 0- 7 3 9 Address City �' ( State Zip -3 315 7 City State Oaon cc �z 1 z w x a s Phone q-7 2-7$6 6� 5 5( a W _Zip Phone J Z I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $190 for the first hour a g ^ ccand $65 per each additional hour in addition to the review fees. Minimum charge one -hour. vain NTj 1 s' Request: Date: w w LLw ¢ 2ntl Request: Date: cc 3rtl Request: Date: Z 5 1 am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline. IL Additional review fees may apply. a Zo 03 1s' Request: Date: W ow 2ntl Request: Date: 5� w 3r° Request: Date: 0 123 01-192 12/09 BUILDING PERMIT CATEGORIES CATEGORY DESCRIPTION PERMIT TYPE BUILDING 01 GENERAL BUILDING -COMMERCIAL MBLD 02 SUB -GENERAL BUILDING -RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 •••• COMMUNICATION TOWER MBLD ,1J% •,,,,• 'DEMOLITION MBLD 2% • •MIETAL AWNING & STORM SHUTTER MBLD ,z••. •••••: :..SCREEN ENCLOSURES MBLD f5... :-:-SWIMMING POOL MBLD 56 .• ,;; .00-7FNNIS COURTS (SURFACE PAVING) MBLD :'.', . '•*TRAILER TIE DOWN MBLD $g•�r• 9 0 •. : ��7�V�ALK-IN-COOLER MBLD 91 ��• �'• .0 •• MARINAS MBLD ,91% , �' ;' • YL W-SLOPE APPLICATIONS (GRAVEL, SMOOTH ""•0 .` .MODIFIED, SINGLE PLY) MBLD �•: .. •.SHINGLES (ASPHALT, FIBERGLASS) MBLD 96 �••�•• SHINGLES (METAL ROOFS/WOOD SHINGLES & SHAKE) MBLD 97 STAGE 2 VAPOR RECOVERY SYSTEM MBLD 99 SOIL IMPROVEMENT MBLD 0100 BULK STORAGE PROPANE TANK MBLD 0101 REMOVABLE STORM PANELS MBLD 0107 TILE -ROOF MBLD 0110 WATER MAIN MBLD 0111 SITE PLAN MBLD 0112 INDOOR EVENT/EXHIBIT MBLD ELECTRICAL 04 FIRE ALARM SPECIALTY MELE 16 SPECIALTY WIRING MELE 38 GENERATORS MELE LPGX 01 LIQUEFIED PETROLEUM GAS MLPG 02 MISCELLANEOUS MLPG 04 LIQUEFIED PETROL. GAS/STATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKS/PUMPS & POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE tqCOWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 ....... Upright 5.6K, 1/2- NPT TY323 ...... Pendent 5.6K, 1/2- NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion -Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)` *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psis/2 (80,6 LPM/bars/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F(79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ................... Bronze Button .............. Brass/Copper Sealing Assembly ......... Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........ Bronze Deflector ................. Bronze Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: 1 Frame 2 Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector can be provided on special request. ESCUTCHEON PLATE 6 - Deflector* DEFLECTOR* SEATING SURFACE 7/1 (11,1 mm) NOMINAL 2" MAKE -IN (50,8 mm) 2" III Ili 1 3/8" (50,8 mm) I c STYLE 15 or 20 1/2" 7/16" (11,1 mm) RECESSED NPT** NOMINAL MAKE -IN ESCUTCHEON 1/2" NPT** DEFLECTOR WR FI 2-7/8"(73,0 mm) DIA. —y CROS SECTION UPRIGHT PENDENT RECESSED PENDENT •*,,•.• 7 FIGURE 1 • : 91;1JlES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS • • • • • • 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE �� :�� • WRENEH RECESS (U e NLY .; FIGURE • •'••VQTYPLr6 •• SPF?hWLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141 °C) temperature ratings. A leak -tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe -thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 N m). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16" Ll (9,5±7,9 mm) MOUNTING 1/8" SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMMLY (,TY323) WITH TWO PIECE 518 INCH TOTAL ADJCISTPE.NT STYLE-15 • • RECESSED ESCUTCHEON • + • 2-7/8" DIA. • • • • • • • : • (73,0 mm) "' • • • • FACE OF ••• • •• SPRINKLER 2-1/4" DIA. , ••••• • ••• •• 57,2 mm • • • • FITTING ( ) •. •• ,• • •. 5/16±1/4" ; • ; 112" (,12,7 nim) (7,9±6,4 mm) • • •' • FEUSHrr • �. .I i .... MOUNTING 2 m SURFACE (3,mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP172 Page 4of4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2"NPT) TY313 3 PURE WHITE (RAL9010)' POLYESTER 371 5.6K PENDENT (1/2" NPT) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I 9 CHROME PLATED " Eastern Hemisphere sales only •••••� .'. : TABLE �; • •; • • SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS • • • • • • • PART NUMBER SELECTION :..Timat d ,....• .::04 . *see •.Warranty :--r. ' • For warranty terms anci:QQ�i;ons, visit • : • •v9 V w.tyCO�ire.com. • Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify') finish, P/N (specify') Specify: Style 20 Recessed Escutch- eon with (specify`) finish, P/N (specify') . Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F (57°C) 155 155'F (68°C) 175 175°F(79°C) 200 200'F (93°C) 286 286°F (141°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. *„C� TEFLON is trademark of The DuPont Corporation. Fire Protection Products � •►�• - yt4 � }' �.•p= ! r i F R wa " �.y.. ,tiM • rr s— . �' L6.f +>r `K it k� �- 'W ,„ R. r3 •� k�, c� as o �G �w r.,R -a .'s� ^+. �� + � r ^r °r- i �''s a„745' e w �c ,b Certificate of Completion Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel:305-795-2204 Fax:305-756-8972 Building Inspection Department This certificate issued pursuant to the requirements of the Florida Building Code 106.1.2 certifying that at the time of issuance this structure was in compliance with the various ordinances of the jurisdiction regulating building construction or use. For the following: Description: INTERIOR REMODEL FOR PUBLIX SUPERMARKETS Permit Type Building (Commercial) Bldg. Permit No. CC-4-18-902 Owner PUBLIX SUPERMARKETS, INC Contractor OAK CONSTRUCTION CO Subdivision/Project Date Issued 04/01/2019 Construction Type 11-B Occupancy M - 1730 Occupants Type Square Footage 791.00 Flood Zone AE-8 Location If the building is located in a special flood hazard area documentation of the as -built lowest floor 9050 BISCAYNE BLVD elevation or lowest horizontal structural member has been provided and is retained in the records of Miami Shores, FL 33138 Miami Shores Village. � o 5•ffi. . This certificate issued pursuant to the requirements of the Florida Building Code certifying that at the - time of issuance this structure was in compliance with the various ordinances of the jurisdiction regulating building construction or use. rtN Building Officials Approval Not Transferable POST IN A CONSPICUOUS PLACE tz r ca . a�, % tip/�..� .h;. ..:..N L7+�_J+�, ]:•:.: ... lvm ,.L ,i iJSY'h, a.... �,,. Ismael Naranjo, CBO r I INSVEC TION RECORD Permit NO: ♦.iV -4— 1 ®-902 Miami Shores Village "' Permit Type: Commercial Construction 10050 N.E.2nd Avenue Miami Shores, FL 33138-0000 Work Classification: Alteration Phone: (305)795-2204 Fax: (305)756-8972 Issue Date: 9/17/2018 Expires: 03/1 6/201 9 INSPECTION REQUESTS: (305)762-4949 or Log on at https://bidg.miamishoresvillage.com/cap REQUESTS ARE ACCEPTED DURING 8:30AM - 3:30PM FOR THE FOLLOWING BUSINESS DAY. Requests must be received by 3 pm for following day inspections. Commercial Construction Parcel #:1132060100010 Owner's Name: PUBLIX SUPERMARKETS, INC Job Address: 9056 BISCAYNE Boulevard I Miami Shores FL 33138- Bond Number: Contractor(s) Phone Primary Contractor OAK CONSTRUCTION CO (954)583-9625 Yes -� Owner's Phone Total Square Feet Total Job Valuation (863)688-747_ 19700 $ 315,100.00LA WORK IS ALLOWED: MONDAY THROUGH FRIDAY, 8:OOAM - 7:OOPM. SATURDAY 8:OOAM - 6:OOPM. NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS. BUILDING AND ROOFING INSPECTIONS ARE DONE MONDAY THROUGH FRIDAY. NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS THE PERMIT APPLICANT'S RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. INSPECTION DATE INSP Foundation Stemwall Slab Columns (1st Lift) Columns (2nd Lift) Tie Beam Roof Sheathing _ Bucks Interior Framing Insulation Ceiling Grid Drywall Firewall Wire Lath Pool Steel Pool Deck Final Pool Final Fence Screen Enclosure Driveway Driveway Base Tin Cap Roof in Progress Mop in Progress Final Roof Shutters Attachment Final Shutters Rails and Guardrails DADA compliance ; DOCUMRYTS" I. ; Soil Bearing Cert Soil Treatment Cert Floor Elevation Survey Reinf Unit Mas Cert Insulation Certificate Spot Survey Final Survey Truss Certification STRUCTURAL COMMENTS WINDOWS & DOORS INSPECTION DATE INSP Attachment PUBLIC INSPECTION WORKS DATE INSP Excavation ELECTRICAL INSPECTION DATE INSP Temporary Pole 30 Day Temporary Pool Bonding Pool Deck Bonding Pool Wet Niche Underground Footer Ground Slab Wall Rough Ceiling Rough Rough Telephone Rough Telephone Final TV Rough TV Final Cable Rough Cable Final Intercom Rough Intercom Final Alarm Rough Alarm Final Fire Alarm Rough Cl Fire Alarm Final `,;'l Service Work With 2� i 7 ELECTRICAL COMMNTS /�oDeT e)z, m J-- 1 La Z L f \-1 't INSPECTION DATE Final Sprinkler Final Alarm INSP INSPECTION Water Service 2nd Rough Top Out Fire Sprinklers Septic Tank Sewer Hook-up Roof Drains Gas LP Tank Well Lawn Sprinklers Main Drain Pool Piping Backflow Preventor Interceptor Catch Basins Condensate Drains HRS Final DATE I INSP PLUMBING COMMENTS INSPECTION I DATE I INSP Underground Pipe I I t Rough Ventilation Rough Hood Rough Pressure Test Final Cal lcry Final Ventilation Final Pool Heater Final Vacuum MECHANICAL 14 b> iltOOVA, &�- t�(i Miami -Dade County Building Department Page 1 of 2 e-Permitting Search: miamidade.gov MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/19/2019 MUNICIPAL NO.2018-081065 FOLIO: 1132060100010 JOB SITE ADDRESS 9050 BISCAYNE BLVD PROPOSED USE RETAIL SALES /INTERIOR REMODEL LEGAL 6 53 42 5.14 AC M/L SHORES CENTER PB 49-42 APPLICATION TYPE ALTER INTERIOR 19700 SQFT 0 UNITS 0 FLOORS OWNER NAME NORTHERN TRUST BANK ETAL TRS CONTRACTOR QUALIFIER PERMIT TYPE MUNICIPAL BLDG CATEGORIES 0001 MUNICIPAL GENERAL BUILDING DATE: 3/19/2019 PROCESS NUMBER: M2018009927 NEW *AMOUNT PAID 1563.71 DERM 120 MISC FEES (MA 120.00 DERM 1 ASBESTOS REVI 175.00 DERM 1 UP FRONT FEE- 80.00 DERM 1 MIN COMM REV(90.00 DERM 1 AIR SECTION D 200.00 FIRE 315000 ALTERATIONS & 732.40 FIRE 315100 FIRE UPFRT FE 72.57 FIRE 3 SRI PLAN REVI 361.00 RSUR 4 RER 7.5% SUR 37.88 UBS1 1 BLDG 7.5% UPF 1.88 UPMU 1 UPFRONT FEE F 25.00 URS1 1 RER 7.5% UPFR 6.00 9/ 4/2018 09:55 BNZWEB1 181809040389 WEBIPAS 1563.71 MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/19/2019 MUNICIPAL NO.2018-081065 PROCESS NO. M2018009927 FOLIO: 1132060100010 JOB SITE ADDRESS 9050 BISCAYNE BLVD PROPOSED USE RETAIL SALES /INTERIOR REMODEL REQUIRED INSPECTIONS INIT DATE FIRE 0001 FIRE INSPECTIONS RECOMMENDED 200 FIRE HYDRANTS 208 FIRE TCO INSPECTION 211 PRELIMINARY 209 FIRE FINAL MUNICIPAL INSPECTION REQUIREMENTS AND RECORD 03/19/2019 MUNICIPAL NO.2018-081065 PROCESS NO. M2018009927 FOLIO: 1132060100010 JOB SITE ADDRESS 9050 BISCAYNE BLVD PROPOSED USE RETAIL SALES /INTERIOR REMODEL TO SCHEDULE A FIRE INSPECTION, PLEASE VISIT THE WEB AT WWW.MIAMIDADE.GOV/BUILDING OR WWW.MIAMIDADE.GOV/FIRE. YOU WILL NEED TO PROVIDE YOUR TEN DIGIT MUNICIPAL INSPECTION NUMBER AND INSPECTION TYPE. THE INSPECTION TYPE CAN BE FOUND ON YOUR INSPECTION REQUIREMENTS AND RECORDS CARD. IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING AN INSPECTION, MIAMI-DADE http://egvsys.co.miami-dade.fl.us:1608/W WWSERV/ggvtBNZAW922.DIA?PROS=M20... 3/19/2019 Miami -Dade County Building Department Page 2 of 2 SCHEDULING A PRELIMINARY INSPECTION, OR LOAD BANK TEST INSPECTION, PLEASE CALL FIRE PREVENTION AT 786-331-4800. IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING A PLAN REVIEW, PLEASE CALL FIRE ENGINEERING AT (786) 315-2771. **BE ADVISED THIS IS NOT A PERMIT. PERMIT IS TO BE ISSUED BY YOUR CORRESPONDING MUNICIPAL BUILDING DEPARTMENT. Back to Main Menu BLDG Home Page i BLDG Main Menu i BLDG Permit Menu i BLDG Plans Processing Menu i Inspection Types i Address Format Home i About I Phone Directory i Privacy i Disclaimer E-mail your comments, questions and suggestions to Webmaster This page was last edited on: February 23, 2004 Web Site © 2004 Miami -Dade County. All rights reserved. http://egvsys.co.miami-dade.fl.us:1608/W WWSERV/ggvt/BNZAW922.DIA?PROS=M20... 3/19/2019 Lk'111101LWw'ffl FTTV�w WIWI, 9, RW Emb PLUMBING d ic. 6299 Johnson Street • Hollywood, FL 33024 • (954) 961-5527 • Fax: (954) 962-1521 DATE p NAME OF PREMI STREET ADDRESS v 7 e SEE INVOICE # PERMIT # PROPERTY OWNER NAME CITY I—L VVLM 7D rM F ZIP r LOCATION OF DEVICE TYPE OF DEVICE: RP ❑ 1�,�D.C. ElPVB�CI SIZ ACCO NTH#�f'� MANUFACTURER � ' S , ` METER # L/(� C� v MODEL NUMBER `� > SERIAL # PRESSURE DROP ACROSS FIRST CHECK VALVE 6 PSI CHECK VALVE #1 CHECK VALVE #2 DIFFERENTIAL PRESSURE VACUUM PRESSURE RELIEF VALVE BREAKER INITIAL 1. LEAKED ❑ LEAKED ❑ AIR INLET TEST OPENED AT LBS. OPEN AT LBS. 2. CLOSED TIGHT CLOSEDTIGHT ❑ DID NOT OPEN ❑ DID NOT OPEN ❑ CLEANED ❑ CLEANED ❑ CLEANED ❑ CHECK VALVE REPLACED REPLACED REPLACED LEAKED ❑ RUBBER PARTS KIT ❑ RUBBER PARTS KIT ❑ RUBBER PARTS KIT ❑ CLOSEDTIGHT ❑ C.V. ASSEMBLY ❑ C.V. ASSEMBLY ❑ C.V. ASSEMBLY ❑ OR OR OR CLEANED ❑ REPLACED R DISC ❑ DISC ❑ C.V. ASSEMBLY ❑ E O-RINGS ❑ O-RINGS ❑ DISC ❑ DISC. AIR INLET ❑ P SEAT ❑ SEAT ❑ DIAPHRAGM ❑ DISC. C.V. ❑ A SPRING ❑ SPRING ❑ SEAT ❑ SPRING ❑ I STEM/GUIDE ❑ STEM/GUIDE ❑ SPRING ❑ RETAINER ❑ R LOCK NUTS ❑ LOCK NUTS ❑ O-RINGS ❑ O-RING ❑ OTHER ❑ OTHER ❑ OTHER ❑ OTHER ❑ FINAL- OPEN AT LBS. TEST I CLOSEDTIGHT ❑ CLOSED ❑ REDUCED PRESSURE SATISFACTORY ❑ NOTE: ALL REPAIRS/REPLACEMENT SHALL BE COMPLETED WITHIN TEN (10) DAYS. DIFFERENTIAL PRESSURE ACROSS CK VALVE #2 - REMARKS: I HEREBY CE TIFY THAT THIS DATA IS ACCURATE AND REFLECTS THE PROPER OPERATION AND MAINTENANCE OF THE UNIT. PASSED FAILED - REPAIR NEEDED p INITIAL TEST BY CERTIFIED TESTER NO. 41 REPAIRED BY FINAL TEST BY_ CERTIFIED TEST CERTIFIED TESTER NO. EXP. MO. DAY YR. DATE EXP. EXP. MO. DAY YR. DATE CG�Q` (WHITE) - CITY (YELLOW) - (PINK) - FILE �� i r 62/ta4l moswa,41 IC. 6299 Johnson Street - Hollywood, FL 33024 - (954) 961-5527 - Fax: (954) 962-1521 DATE 4 SEE INVOICE # PERMIT # f PROPERTY OWNER NAME NAME OF PREMISE STREET ADDRESS -/ �j o L CITY ZIP L LOCATION OF DEVICE TYPE OF DEVICE: RP )C j D.C. ❑ PVB ❑ SIZE A COUNT # MANUFACTURER L �1�+1�•S METER 4,023�� MODEL NUMBER t;�Z(� SERIAL # PRESSURE DROP ACROSS FIRST CHECK VALVE CHECK VALVE #1 CHECK VALVE #2 DIFFERENTIAL PRESSURE VACUUM PRESSURE RELIEF VALVE BREAKER INITIAL 1. LEAKED ❑ LEAKED ❑ V AIR INLET TEST OPENED AT LVI LBS. OPEN AT LBS. 2. CLOSED TIGHT kr CLOSEDTIGHT DID NOT OPEN ❑ DID NOT OPEN ❑ CLEANED ❑ CLEANED ❑ CLEANED ❑ CHECK VALVE REPLACED REPLACED REPLACED LEAKED ❑ RUBBER PARTS KIT ❑ RUBBER PARTS KIT ❑ RUBBER PARTS KIT ❑ CLOSED TIGHT ❑ C.V. ASSEMBLY ❑ C.V. ASSEMBLY ❑ C.V. ASSEMBLY ❑ OR OR OR CLEANED ❑ REPLACED R DISC ❑ DISC ❑ C.V. ASSEMBLY ❑ E O-RINGS ❑ O-RINGS ❑ DISC ❑ DISC. AIR INLET ❑ P SEAT ❑ SEAT ❑ DIAPHRAGM ❑ DISC. C.V. ❑ A SPRING ❑ SPRING ❑ SEAT ❑ SPRING ❑ I STEM/GUIDE ❑ STEM/GUIDE ❑ SPRING ❑ RETAINER ❑ R LOCK NUTS ❑ LOCK NUTS ❑ O-RINGS ❑ O-RING ❑ OTHER ❑ OTHER ❑ OTHER ❑ OTHER ❑ FINAL- OPEN AT LBS. TEST I CLOSEDTIGHT ❑ I CLOSED ❑ REDUCED PRESSURE SATISFACTORY ❑ NOTE: ALL REPAIRS/REPLACEMENT SHALL BE COMP L TED WITHIN TEN (10) DAYS. DIFFERENTIAL PRESSURE ACROSS CK VALVE #2 4,a. REMARKS: I HEREBY C RTIFY THAT THIS DATA IS ACCURATE AND REFLECTS THE PROPER OPERATION AND MAINTENANCE OF THE UNIT PASSED e/ FAILED - REPAIR NEEDED INITIAL TEST BY CERTIFIED TESTER NO. /10 REPAIRED BY FINAL TEST BY_ CERTIFIED TEST CERTIFIED TESTER N EXP. MO. DAY YR. DATE EXP. MO. DAY YR. DATE � O (WHITE) - CITY (YELLOW) - (PINK) - FILE 12043 6512 NW 54ei Ct, Lauderhill FL 33319 Cell 754-235-7126 / Office: 954-709-5249 NOTICE OF TERMITE PROTECTION TREATMENT As Required By Florida Building Code (FBC) 104.2.6 FProperty Info mation Builder/Contractor r y Date/ 2 /�/X5_ ,anent Name of Builde9(' TreatmentTime /' P Lot _ i`i' _/ 9 4 Shell Contractor Block X1,�E Subdivision Name��4 Street Address D 5D tS�/i 1 �LOIVIonolithic CONSTRUCTION TYPE: ©r S/F OF Stemwall S/F L/F City/State/Tap Mt d ` M ( 40K� F� Patio U S/F F / Additions S/F L/F CHEMICALTYPE: C yper To Cypermethrin ❑ Termidor Fipronil `❑ `Dragnet Permethrin *pray Only ❑ Pro Build TC Cypermethrin ❑ Permise Pre -Construction ❑ Spray and Tamp ❑ Other Imidacloprid ❑ Residential 6rcommercial . YTREATMENTTYPE: Chemical % nderslab Date of Comp tion ✓jam G ❑ Footers 7 3 T � TJ Gallons % ❑ Wood Treatment Applicator GUARANTEE RENEWAL ❑ None ❑ Yes ❑ 1 Year ❑ No ❑ 5 Years NO LIMIT TERMITE & PEST SERVICES, LLC. hereby confirms that this building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and laws as established by Florida Depart- ment of Agriculture and Consumer Services. Exterior perimeter treatment was completed upon final grade.