O-343-69 ORDINANCE NO.
AN ORDINANCE AMENDING AND REENACTING THE PROVISIONS OF
ORDINANCE No. 287 OF MIAMI SHORES VILLAGE , ADOPTING
THE SOUTH FLORIDA BUILDING CODE AS THE BUILDING CODE OF
MIAMI SHORES VILLAGE AND FOR OTHER PURPOSES.
BE IT ORDAINED BY MIAMI SHORES VILLAGE, FLORIDA: THAT ORDINANCE
NO. 237 OF MIAMI SHORES VILLAGE BE AMENDED AND REENACTED SO THAT
THE SAME SHALL READ AS FOLLOWS :
SECTION 1. ADOPTION � OF BUILDING, PLUMBING, ELECTRICAL
AND RELATED TECHNICAL CODES.
The document marked, designated, and known as the
"South Florida Building Code, " which is made a part hereof by
reference, is hereby adopted as a minimum standard for the purposes
expressed therein and shall be known as the "Building Code of Miami
Shores Village, " and this document shall be as.-fully effective
as though every word, phrase, sentence, or section of the South
Florida Building Code were fully incorporated herein, except as
modified or added to in sections of this ordinance which follow.
SECTION 2. AUTHORITY.
Wherever the terms "Building Official, " "Plumbing
Inspe ctor, " "Electrical Inspector, " "jurisdiction, " "Regulatory
authority, " or similar terms shall appear, they shall refer to the
properly designated inspectors or assistant inspectors of the
Building Department of Miami Shores Village, and to the authority
and jurisdiction of Miami Shores Village and its officials and
employees.
SECTION 3. QUALIFICATIONS OF INSPECTORS AND PERS0.=EL.
.The qualifications of the Building Inspector, Plumbing
Inspector, and Electrical Inspector, and other personnel of the
Building Department, shall be established by the Village Manager.
SECTION 4. APPLICATION FOR BUILDING PERMITS.
No person shall erect or construct or proceed with
the erection or oncsturction of any building or structure, now add--
to, enlarge, move, improve, alfter, convert, extend, or demolish
any building or structure, or any group of buildings and/or
structures under one or joint ownership whether on�.one or more
lots or tract of land; or cause the same to be donem where the cost
of work is 11-vienty-five Dollars ($25.00) or more in value; and on
any remodeling or alteration job of any value, without first
obtaining a buildingi3ennit therefor from the Building Department.
SECTION 5. BUILDING PERMIT FEES.
The office of the Building Department of Miami Shores
village, shall charge and collect for building permits at the following
rates, to wit:-
A. Double Fees:
When work for which a permit is required is
commenced prior to the obtaining of a permit,
the fees, as specified herein, may be doubled,
but in no event shall such doubled fee be less
than Ten Dollars ($10.00) . The payment of such
double fee shall not relieve any person, firm or
corporation from fully complying with all of
the requirements of all applicable regulations
and codes, nor shall it relieve them from being
subject to any of the penalties therein. The
double fee requirement shall be applicable to
all Divisions of the Building Department.
MINIMUM FEE . . . . . . . . . . . . . . . . . . . .$10-00
B. When extra inspection trips are necessary due
to (1) wrong address being gLven on call for
inspection (2) prior rejection of work due to
faulty construction (3) work not being ready
for inspection at time specified, (4) failure
to call for final or other inspections, (5)
required corrections not being made or completed
at time specified, a fee of Five Dollars -.($5.00)
for each reinspection may be charged. . . . . . . . .
The payment of reinspection fees may be required
before any further permits will be issued to the
person or firm owning same, and further inspections may
be re fused and to ther-erson or firm owing same, and
_2-
further inspections may be refused until payment
of reinspection fees have been made . . . . . . .
Reinspection of existing buildings by all
Divisions to determine compliance with the
South Florida Building Code, but not annual
inspections as required by 305.1 (d) . . . . . . . �5.00
C. REFUNDS, TTME LIMITATION, REVOCATION, ETC.
The fees charged pursuant to this ordinance
provided the same are for a permit required by
Section 301.1 of the South Florida Building
Code, may be refunded by the Director of the
Building & Zoning Department, subject to the
following:
(1) No refund shall be made where any
work has conmanced except where duplicate
permits a-re issued for the same work, in
which case a refund in accordance with
item 4 may be granted to the prior
issued permit holder providhg the duplicate
permits were issued within ninety (90) days
of each other and request for refund is
received within ninety (90) days of the
issuance of the latter permit.
(2) No refunds shall be made where permit has
become void as provided by Paragraph 304.3 (a')
of the South Florida Building Code.
(3) No refunds shall be made on permit fees of
Four Dollars ($4.00) or less
(4) Refunds on permits or any item thereon Vaere
fees are over Four Dollars ($4.00) will be
refundable on a basis of eightypercent (80%)
of the balance over Four Dollars ($4.00) ,
such refunds to be made to the closest dollar.
(5) Full refunds may be granted to a permit
holder whose permit is cancelled by owner
authorization where work has comnaenced and
such owner selected a second contractor to
complete the work. The second contractor
shall pay a full fee to complete the work
unless the first contractor waives his oppor-
tunity to a refund in writing, in which case,
the second cont-rac_or J.F. c:�nt.il-. Led tc, a
to cover the same work on a "no charge" basis.
(6) A full refund may be granted to a permit
holder who takes out a permit covering work
outside the jurisdictional inspection area.
-3-
D. BUILDING PERMIT FEES:
(Fees listed here do not include plambing, electrical
or mechanical installations or use and occupancy fees)
(1) NEW BUILDING ANDAR. ADDITIONS :
For each 100 sq. ft. or fractional
part of floor area . . . . . . . . . . . . $ 2.25
Minimum fee . . . . . . . . . . . . . . . 115.00
Except that for buildings for storage
and industrial uses of the Group E
and F Occupan6ies as defined in the
South Florida Building Code, the fee
shall be:
For each 100 sq. ft. , or fractional
part of floor area up to 20,000
sq. ft. . . . . . . . . . . . . . . . 205
For each additional 100 sq. ft. or
fractional part of floor area there-
after . o . o . o . . . . . . . . 1.00
Minimum fee . . . o o . . o . . . o JlOoOO
Except that for greenhouses and build-
ings for agricultural uses (nonresidential)
when located on the premises so used, screen
enclosures and trailer additions:
For each 100 sq. ft. or fractional
part of floor area . . . . . . . . . . . 100
Minimum fee . . . . . . . . . . . . . . 5.00
(2) NEW CONSTRUCTION OTHER THAN AS SPECIFIED
HEREIN: (WATER TOWERS, PYLONS, BULK
STORAGE-TANX FOUNDATIONS, SEA WALLS,
BULKHEADS, UNUSUAL LIMITED-USE BUILDINGS,
PREE-STANDING RIGID CANOPIES, MARQUEES
AND SIMILAR CONSTRUCTION)
For each $1,000 of estimated cost
or fractional part . 205
Minimum permit fee . . . . . . . . . $10.00
(Except for each service station
underground-storage tank and each
approved fallout shelter which
conforms to the specifications
established by the Civil Defense and
mobilization agency and the South
Florida Building Code. ) . . . . . . o . . 5.00
Minimum fee XStorage Tank Only) . . o $10o00
-4-
(3) ALTERATIONS AND REPAIRS TO BUILDINGS
AND OTHER STRUCTURES:
Up to �1,000.00 of estimated
cost or fractional part . . . . . . . . $ 5.00
For each additional $1,000 of
estimated cost or fractional part . . . � 2.50
(4) INSTALLATION OF EXTERIOR OPERABLE
WINDOWS A.ND EXTERIOR, SLIDING GLASS
DOORS IN NEW BUILDINGS OR ADDITIONS
EXCEEDING TWO STORIES IN HEIGHT AND
TIE INSTALLATION, ALTERATION AND
REPAIR OF SUCH WINDOWS AND DOORS IN
EXISTING BUILDINGS OF ANY HEIGHT, AS
FOLLOWS :
New installation or replacement for
each window or door unit up to the
first 100 units* . . . . . . . . . . . .50
For each additional unit . . . . . . . .25
Minimum fee . . . . . . . . . . . . . 2.00
Unit is the opening between
structural columns
(5) INSTALLATION OF CURTAIN WALLS, INCLUDING
WINDOWS AND DOORS THEREIN AND THE ALTER-
ATION, REPAIR OR REPLACEMENT OF STORE
FRONTS AND SIMILAR FIXED GLASS
For each 100 sq. ft. or fractional
part thereof up to 1,000 sq. ft. . . $ 1.00
For each additional 100 sq. ft. or
-C
fractional part thereof . . . . . . . .50
Minimum fee . . . . . . . . . . . . . $ 2.00
(6) MOVING BUILDINGS OR OTHER STRUCTURES:
Per Building or Structure . . . . . . $25.00
For each 100 sq. ft. or fractional
pa_rt thereof - (does not include
cost of new foundation or repairs
to building or structure . . . . . . . $ 1.00
(7) CONCRETE SLABS : (OTHER THAN PAVING)
(Where separate installation not
covered by prior permit)
For first 1,000 sq. ft. or fractional
part thereof . . . . . . . . . . . . . $ 5.00
For each additional 1,000 sq. ft. or
fractional part of area . . . . . . . $ 2.00
-5-
PAVING
(on other than public right of way
and excluding paving in connection
with single family and duplex use)
For first 1,000 sq. ft. or
fractional part of area . . . . . $ 5.00
For each additional 1,000 sq.
ft. or fractional part of
area . . . . . . . . . . . . . . 1.00
(9) ROOFING: (Including reroofing)
For first 2,000 sq. ft. or
fractional part of area . . . . . 2 .00
For each additional 1,000 sq.
ft. or additional part of area 2.00
(10) FENCES AND/OR WALLS
For each 100 lineal feet or
fractional part . . . . . . . . . 3.00
(11) AWNINGS AND CANOPIES:
First $1,000 of estimated cost 5.00
For each additional $1,000 or
fractional part thereof . . . . . . 2.00
'(12) SWIXMING POOLS :
For the first 20,000 gallon
capacity or fractional part . . . 20.00
For each additional 1,000 gallon
capacity or fractional part . . . 1.00
(13) TEMPORARY PLATFORMS AND TEMPORARY
BLEACIMRS TO BE USED FOR PUBLIC
ASSEMBLY:
For each 100 sq. ft. or frac-
tional part of platform area 2 .25
For 100 lineal feet or fractional
part of seats . . . . . . . . . . 1.25
(14) DaM.OLITION OF BUILDINGS:
For the first 1,500 sq. ft. or
fractional part of floor area 5.00
For each additional 1,000 sq. ft.
or fractional part of floor area 2.00
-6-
(15) DEMOLITION OF SIGNS, FENCES
AND/OR WALLS AND STRUCTURES
OTHER THAN ABOVE
For each �100. or fractionai-
part of estimated cost up to
$1,000 . . . . . . . . . . . . . . 1.25
For each additional $1,000 or
fractional part of estimated
cost . . . . . . . . . . . . . . . 2 .25
(16) COMPLETION PERMIT FEE:
(To be charged only when work has
commenced and previous permit
expired) . . . . . . . . . . . . . 5.00
PLUMBING PERMIT FEES :
(1) ROUGHING-IN OR PLUGGED OUTLETS FOR:
BATH TUBS, CLOSETS , DOCTORS, DENTISTS,
AND HOSPITAL STERILIZERS, AUTOCLA VES,
AUTOPSY TABLES AND OTHER FIXTURES , AP-
PURTENANCES OR OTHER APPLIANCES HAVING
WATER SUPPLY OR WASTE OUTLET, OR BOTH,
DRINKING FOUNTAINS, FIXTURES DISCHARGING
INTO TRAPS OR SAFE WASTE PIPES, FLOOR
DRAINS, LAUNDRY TUBS, LAVATORIES, SAFE
WASTE PIPES, SHOWERS, SINKS, SLOP SINKS,
URINALS:
For first roughing-in or plugged outlet . . . 1.25
For each additional outlet . . . . . . . . . . 1.25
Fixtures set on new roughin-in or
plugged outlets or replaced on old
roughing-in:
First fixture . . . . . . . . . . . . . . 1.25
Each additional fixture . . . . . . . . 1.25
(2) SEPTIC TANKS, SETTLING TANKS, GAS AND
OIL INTERCEPTORS, GREASE TRAPS AND
SOAKAGE PITS: (Including draintile for
same)
1200 gallon capacity or less 4.00
over 1200 gallon capacity . . . . . . . 5.00
Draintile relay . . . . . . . . . . . . 4.00
Tank abandonment (where being abandoned) 4.00
(3) SEWER:
Each building storm sewer and each
building sewer where connection is
made to a septic tank, to a collector
line or to an existing sewer or to a
city sewer or soakage pit or to a
building drain outside a building . . . 3.00
SEWER CAPPING . . . . . . . . . . . . . . . 5.00
-7-
(4) WATER DRAIMkGE:
PAIN WATER ROOF INLET:
First inlet . . . . . . . . . . . . . $ 2 .00
Each additional inlet . . . . . . . . 1.00
AREA, YARD, SIDEWALX OR RAINWATER
DRAIN FOR WHICH NO OTHER FEE IS
PROVIDED:
First surface inlet . . . . . . . . . 2 .00
Each additional inlet . . . . . . . . 1.00
Each soakage pit . . . . . . . . . . 5.00
(5) CONDENSaTEZ DRAIN:
Per Outlet . . . . . . . . . . . . . 1.00
Except single not manifolded A/C
outlet, not exceeding 5 hp No Charge
(6) WATER PIPING:
Water service connection to a
municipal or private water supply
system (for first meter on each lot) 3.00
Each additional meter on same lot . . . . 2.00
Water connection to or outlets for
appliance or installations not covered
by fixtures or other permit . . . . . . . 2.00
Irrigation system and underground
sprinkler system, etc. . . . . . . . . . 5.00
Fire sprinkler system connection to
city water . . . . . . . . . . . . . . . . 5.00
Fire control system, including
standpipe, siamese connections,
and pumps :
Each standpipe . . . . . o . . . . . 3.00
Each hose rack . . . . . . . . io0o
Standby for emergency potable
water supply outlet . . . . . . . . . . . 5.00
Solar waterheater installations
or repairs . . . . . . . . . . . . . . . 5.00
Solar waterheater booster connection 2.00
Swimming pool piping installations,
not including wells . . . . . . . . . . . 5.00
-8-
Swimming pool piping replacement
or repair work (each job) . Fee
only for jobs, costing more than
$25.00 (material and labor) unless
hydraulics of piping system on
lesser' job affected . . . . . . . 4.00
Repairs to water piping . . . . . 4.00
(Fee only for jobs costing more than
$25.00 (material and labor)
(7) WELLS:
All wells . . . . . . . . . . . . 5.00
(8) MINIMUM PLUMBING PERMIT FEE . . . . . . 4.00
Except witbrheater replacement and
water connection from uall to water
service . . . . . . . . . . . . . . 2.00
(9 NATURAL GAS & LIQUEFIED PETROLEUM:
For the first outlet (includes
cylinders and regulators) . . . . . . 2.00
For each additional outlet . . . . . . 1.25
For the first appliance (does not
include warm air heating units) (See Fee
Section G (2) for heating) . . . . . . 1.25
For each additional appliance or
replacement . . . . . . . . . . . . . . 1.25
For first meter . . . . . . . . . . . . 2.00
For each additional meter . . . . . . . 1.25
For change from a master to an
individual meter . . . . . . . . . . . 2.00
For major repairs to gas pipe where no
fixture or appliance installation is
involved . . . . . . . . . . . . . . . 2.00
Underground LY P. Gas tanks . . . . . 5.00
Change of company - (no additional
appliances or outlets) . . . . . . . . 2.00
(10) WATER TREATMENT PLANTS, PUMPING STATION,
SEWAGE TREATMENT PLANT AND LIFT STATIONS:
Water treatment plant (Interior
plant piping) . . . . . . . . . . . . . 10.00
Sewage treatment plant (Interior
plant piping) . . . . . . . . . . . . . 10.00
-9-
Lift station (Interior station
p i,,,)ing) . . . . . . . . . . . . . 5.00
YD GAS MAINS : (On private
(11) WATER Al
property and other than public
utility easements)
MINIMUM FEE PER JOB . . . . . . . 4.00
(12) STORM AINiD SANITARY UTILITY AND/OR
COLLECTOR LINES: (On private property
other than public utility easements)
MINIMUM FEE PER JOB . . . . . . . 4.00
(13) (a) TEMPORARY TOILETS - WATER BORNE
For each installation . . . . . . 4.00
(b) CHEMICAL TOILETS
For each installation . . . . . . 4.00
(14) MISCELLANEOUS:
Siphon breakers on old installations,
required when repair of unapproved
water closet is made, each . . . . 2.25
F. ELECTRICAL PERMIT FEES :
(1) ROUGH WIRING OUTLETS: (Light, receptacle,
switch, sign and also telephone and other
low voltage outlets)
1 through 10 outlets . . . . . . . 2.25
For each additional outlet . . . . .25
(2) SERVICES : (The following fees shall be
charged for each service and for each
subfeed in new installations only. No
charge wij"-1 be made for subfeeds in
existing installations)
Temporary for construction . . . . 3.00
100 ampere and under . . . . . . . 2 .50
over 100 ampere to 200 ampere . . 3.50
over 200 ampe-re to 400 ampere . . 4.50
over 400 wmpere to 600 ampere . . 5.5C
over 600 annere to 800 ampere . . 6.50
For each additional 100 ampere
(over 800 ampere) . . . . . . . . 1 .00
Service repair and/or meter change 3.00
(3) SWITCHBOARDS : (By amperes, same as
"SERVICESO shown in Item F-2 above)
-10-
(4) EQUIPMENT OUTLETS OR PERMANENT CONNECTIONS:
Range . . . . . . . . . . . . . . . . . . 1 1.75
Range top . . . . . . . . . . . . . . . . 1.75
Oven . . . . . . . . . . . . . . . . . . 1.75
�Waterheater . . . . . . . . . . . . . . . 1.75
Spaceheater . . . . . . . . . . . . . . . 1.25
Washing Machine. . . . . . . . . . . . . 1.25
Dryer . . . . . . . . . . . . . . . . . . 1.25
Fan (with fractional HP motor) 1.25
Garbage disposal . . . . . . . . . . . . 1.25
Dishwater . . . . . . . . . . . . . . . 1.25
Deep freezer . . . . . . . . . . . . . . 1.25
Refrigerator . . . . . . . . . . . . . . 1.25
Air conditioners, window and
through wall units . . . . . . . . . . . 1.25
(Motors)
Each up to 1 horsepower . . . . . . . . 1.25
Each over 1 hp through 3 hp . . . . . . 2 .25
Each over 3 hp through 5 hp . . . . . . 3.50
Each over 5 hp through 8 hp . . . . . . 4.50
Each over 8 hp through 10 hp . . . . . 5.50
Each over 10 hp, through 25 hp . . . . . 9.00
Each over 25 hp through 100 hp . . . . ii.00
Each over 100 hp . . . . . . . . . . . 17.00
(Air Conditioners - electrical work
except wall and window units - per ton) 1.00
(5) MACHINE OUTLETS OR PERMANENT CONNECTIONS:
X-ray - Portable (Dentist) . . . . . . 1.25
X-ray - Stationary (Doctor) . . . . . . 5.50
Diathermic. . . . . . . . . . . . . . 1.25
(6) GENERATORS AND TRANSFORMERS, COMMERCIAL
HEATING EQUIPMENT AND STRIP HEATERS :
Each up to 5 EVA or XW . . . . . . . . 2.25
Each generator or transformer over
5 EVA or EW through 10 EVA or EW . . . 4.50
Each generator or transformer over
10 INA or XW through 15 INN or EW . . 6.75
Each generator or transformer over
15 EVA or YW through 20 EVA or XW . . 9.00
Each generator or transformer over
20 EVA or KW through 25 EVA or XW . . ii.00
Each generator or trandbrmer over
25 EVA or EW or over . . . . . . . . 17.00
Generators and transformers, where
located on the same floor, fee for
largest, plus J1.00 for each additional
_11-
(7) WELDING MACHINE OUTLETS:
Up to 25 amperes . . . . . . . . . 2.25
over 25 amperes to 50 amperes . . 3.50
over 50 amperes, 13.50 plus . . . 1.25
for each additional 50 amperes
or fractional part thereof.
(8) SPECIAL PURPOSE OUTLETS: (Commercial)
Popcorn, doughnut, drink machines,
coin music machines, toasters,
coffee urn, deep fryer, telephone
booths, refrigerator, display
cases, etc. each . . . . . . . . . . lo25
Painting - bake ovens, each 5.50
(9) SIGNS:
First 100 bulbs 5.00
Each additional 100 bulbs or
fraction thereof . . . . . . . . . 1.00
Transformers (Neon) for first . . . 200
Each additional transformer 1.50
-"Fleeher . . . . o . o . --l7053-
Time clock . . . . . . . . 1.50
Sign repairs, connection and
reconnection . . . . . . . . . . . 1.50
(10) FIXTURES:
Lights - 1 through 10 sockets . . . . 1.25
1 through 10 fluorescent tubes 1.25
Each additional . . . . . . . . . . . .10
(11) COMBINATION:
Light fixtures and outlets up
through 10 - one inspection . . . . . 2.00
(12) STREAMERS OR FESTOON LIGHTS:
First 10 lights or less . . . 1.25
Each additional 10 or less .75
(13) PLUGMOLD:
First 25 feet . . . . . 1.25
Each 5 feet thereafter . . . . . . .25
(14) TEMPORARY WORK ON CIRCUSES, CARNIVALS, ETC. :
Equipment ground, each . . . . . 1.00
Service as per Item F(2)
Outlets as per items QI) and (13)
MINIMUM FEE, . . . . . . . . . . . . 25.00
-12-
(15) MIj'\TIMLri.4 PEP-MIT FEE INCLUDING REPAIR WORK
NOT ELSEWHERE CLASSIFIED . . . . . . . . . . $ 3.00
(16) FIRE DETECTION SYSTEM:
Installation, Central System . . . . . 3.00
Head or target area, with protectu
or wire of similar character
EACH . . . . . . . . . . . . . . . . . .25
Bell alarm station, each . . . . . . . .25
Reinspection fee, semiannually . . . . 4.50
(17) MASTER TELEVISION AND RADIO RECEIVING
ANTENNAE:
TV and radio antenna devices, wall
outlets, suppressors, splitterso
lightning arrestors, receivers, input
devices, audio amplifiers, ground
connections, etc.
1 through 5 devices . . . . . . . 3.00
Each additional device . . . . . .25
G. MECHANICAL PERMIT FEES:
(1) AIR CONDITIONING AND REFRIGERATION:
(Includes all component parts of the
system except that water, electric
and gas lines and connections are
fee 's separately)
(Where BTU rating is not known, sub-
stitute one horsepower for one ton or
12,000 BUT's for one ton)
For each ton capacity or fractional
part thereof . . . . . . . . . . . . . 2.00
MINIMUM FEE . . . . . . . . . . . . . 3.00
(2) FURNACES AND HEATING EQUIPMENT,
INCLUDING C01MMERCIAL DRIERS, OVENS
AND OTHER FIRED OBJECTS NOT ELSEPMRE
CLASSIFIED (Includes all component
parts of the system except fuel and
electrical lines)
For the f-irst 200,000 BTU per
hour or fractional part . . . . . . . 5.00
For each additional 100,000 BTU
per hour or fractional part . . . . . 2.00
Except for unvented spaceheaters
and vented wall heaters (no duct
work)
First such unit . . . . . . . 3.00
For each additional such unit 1.00
-13-
(3) ELEW�TORS , ESCALATORS AND OTHER
LIFTING APPARATUS :
Fce for permit for original instal-
lation or major revamping (includes
initial inspection and certificate)
Passenger and freight elevators . . . . $10.00
Each landing other than first floor . . 2.00
Escalator, manlifts, dumbwaiters, hand
powered freight elevators and all other
lifting and transporting apparatus
(except as herein otherwise provided) . . 10.00
Material hoists for construction . ]NO fee
Fees for periodic reinspections :
Passenger elevator (annual) . . . . . . 20.00
(Inspected quarterly: first
inspection three months after
installation and inspection
-hs thereafter)
every three mont
Freight elevators, escalator and
construction manlifts (Annual) . . . . 10.00
(Inspected semiannually: first
inspection six months after in-
s-'Callation and inspection every
six months thereafter,
DLL-nbwaiters, hand powered freight
elevators and all other lifting
and transporting apparatus (annual) 5.00
(Inspected annually: First
inspcction twelve months after
installation and inspection
every twelve months thereafter)
(4) AMUSEMENT RIDES AIM DEVICES:
11.00
For each portable or temporary unit
(5) BOILERS AND PRESSURE VESSELS
Installation permit fees (including
initial- inspections and certificate)
(Does not include installation or
connection of fuel and water lines) :
Steam boilers (as defined in the AS.,2
Boiler and Pressure Vessel Code)
Each . . . . . . . . . . . . . 10.00
F.ot water boilers (as defined in the
ASME Boiler and Pressure Vessel Code) :
Each . . . . . . . . . . . . . . . . . . io.Go
_14-
Miniature boilers (as defined in
the ASME Boiler and Pressure
Vessel Code) :
Each . . . . . . . . . . . . . . . . . . 5.00
Steam driven prime movers
Each . . . . . . . . . . . . . . . . . . 10.00
Steam actuated machinernz
Each . . . . . . . . . . . . . . . . . . 2.00
Unfircd Pressure Vessels (Operating
at pressures in excess of 60 psi and
having a volume of more than 5 cu. ft. ) 5.00
FIRE SPRINAZER SYSTEM:
Per sprinkler head . . . . . . . . . . . .10
Minimum permit fee . . . . . . . . . . . 5.00
CO2 and Dry Powder Systems for
estimated cost up to 11,000.00 . . . . . 5.00
For each additional 11,000.00
or fractional part thereof . . . . . . . 2.00
(7) STORAGE TANKS FOR FLAMMABLE LIQUIDS: . . . . 5.00
Q INTERNAL COMBUSTION ENGINES:
Stationary . . . . . . . . . . . . . . 5.00
(9) OTHER FEES :
Pressure and process piping,
sheet metal and duct work and .
other mechanical lines :
For estimated costs up to $1,000.00 5.00
For each additional $1,000.00 or
fractional part .. . . . . . . . . . . . 2.00
H. SIGN PERMIT FEES
(1) CLASS A (TEMPORARY SIGNS)
(a) Not exceeding six (6) square
feet and not electrically illuminated. No charge
(b) Subdivision signs larger than
six (6) squarw feet . . . . . . . . . . 5.00
Renewable every ninety (90) days 3.00
(c) Construction on the premises
(Present or proposed) Real Estate
"For Sale" or "For Rent" signs
larger than six (6) square feet . . . . 3.00
Renewable every ninety (90) days . . . 3.00
-15-
(2) CLkSS B POINT OF SALE SIGNS
(OCCUPANT USE, PRODUCTS SOLD)
(a) Cantilever sign . . . . . . . . . 5.00
(b) Flat sign . . . . . . . . . . . . 5.00
(c) Marquee sign . . . . . . . . . . 5.00
(d) Pylon sign . . . . . . . . . . . 5.00
(e) Detached sign . . . . . . . . . 10.00
(f) Projecting sign . . . . . . . . 5.00
(g) Roof sign . . . . . . . . . . . 10.00
(h) Combination vertical-projecting-
roof sign . . . . . . . . . . . 15.00
(3) CIz�SS C (COMMERCIAL ADVERTISING SIGNS)
(a) Painted Class C signs (on walls
of a building) . . . . . . . . . 7.50
(b) semaphore signs (per standard or
pole) . . . . . . . . . . . . . 3.00
(c) All other Class C signs . . . 12.00
Renewable annually or before
October ll of each year . . . . 3.00
SECTION 6 . ZONING ORDINANCE.
Before any permit is issued, all provisions o.-L' the
Miami Shores Village zoning ordinance No. 270, and any amendnaents
thereto shall be complied with, and the provisions of the Building
Code shall not be construed to repeal, supersede, or modify any
part of the said Zoning Ordinance No. 270 or amendments thereto.
SECTION 7. PEMLTIES.
Any person convicted for violating any of this
ordinance shall, upon conviction thereof in a municipal court of
Miami Shores village, be sentenced to pay a fine not exceeding the
sum of Five Hundred Dollars ($500.00) or serve a term not to
exceed sixty days in the Village jail, or both such fine and
sentence in the discretion of the Municipal Judge.
SECTION 8. SEPARATE OFFENSES.
Each day's violation of any of the terms oi-'-- this
ordinance shall be deemed and considered and is hereby specially
declared to be a separate and distinct violation of the terms of
this ordinance and puAishable as such.
-16-
SECTION 9. SEPARABILITY.
In the event that any portion of this ordinance
shall be held to be void, inconsistent or of no effect by a court
of competent jurisdiction, such holding shall in no wise affect
or disturb the remaining portions of this ordinance.
SECTION 10.,
All ordinances in conflict or inconsistent herewith
are hereby repealed insofar as there is conflict.
SECTION 11.
This ordinance shall become effective immediately
upon its passage.
PASSED and ADOPTED this 18th day of March 1969.
�iL"
mayor
ATTEST:
Villar lerk
-17-
34