Loading...
RF-16-3409Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-273403 Scheduled Inspection Date: Deceriyber 22, 2016 Inspector: Naranjo, Ismael Owner: MACCLELLAN, AMY J P Job Address: 800 NE 95 Street Miami Shores, FL Project: <NONE> Contractor: J&K ROOFING INC it Number: RF -12-16-3409 Permit Type: Roof Inspection Type: Tin Cap Work Classification: Flat Phone Number Parcel Number 1132060410010 Phone: 954-961-7663 Building Department Comments RE -ROOF FLAT WIGAF CAPSHEET Passed 1-fr Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Infractio Passed Comments TIN CAP SPACEING INSPECTOR COMMENTS Inspector Comments False False December 21, 2016 For Inspections pi ase call: (305)762.4949 Page 21 of 27 • Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address 800 NE 95 Street Miami Shores, FL Owner Information Permit Permit NO. IRF -12-16-3409 Permit Type: Roof Work Classification: Flat Permit Status: APPROVED Issue Date: 12/20/2016 Expiration: 06/18/2017 Parcel Number Applicant 1132060410010 Block: Lot: AMY J MACCLELLAN Address Phone Cell AMY J MACCLELLAN 800 NE 95 ST MIAMI SHORES FL 33138-2515 Contractor(s) Phone J&K ROOFING INC 954-961-7663 CeII Phone Type of Work: Re Roof Additional Info: RE -ROOF FLAT W/GAF CAPSHEET Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $3.00 $3.75 $3.75 $1.00 $250.00 $9.00 $4.00 $774.50 Pay Date Pay Type Invoice # RF -12-16-62403 12/20/2016 Check #: 32828 $ 774.50 $ 0.00 Bond #: 3284 Amt Paid Amt Due Available Inspections: Inspection Type: Tin Cap Final Roof Roof in Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zonin I a orize the above-named contractor to do the work stated. December 20, 2016 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy December 20, 2016 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECF-TVED DEC1O 2016 BY: FBC20ne BUILDING Master Permit No. ( � 10" 34 01 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRICOOFING ❑ REVISION D EXTENSION RENEWAL E] PLUMBING ❑ MECHANICAL El PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: e00 ,)g l J (5-t City: Miami Shores County: ?Jae- Miami Dade Zip: 3*'7d Folio/Parcel#: 11-D0 /9- ail - C0) 0 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: ,tQ/oel Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): AM, y 6 C /eJ/4 ✓1 Phone#: 395SSOa - / %47 p Address: £ 0 O lit !S S.4". / �j r/ City: / l i s .M i S 10 fe S State: 1 1 Zip: 3 3 /Jd Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: \ frJ 4o4 Phone#: ,,7/ CV /d -7 Address: ,o?D(O Sh 'fM AA. S+' l( City: fW) fp ` l `( State: 0Zip: -57 e Qualifier Name: 4/kA Q {-�Pl /' O d Phone#: 7 9�7(a Q �Q 7 T State Certification or Registration #: Cr- COS CT ) Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 'off 0 0. 0 0 Square/Linear Footage of Work: d00 Type of Work: ❑ Addition ❑ Alteration ❑ New co Repair/Replace ❑ Demolition Description of Work: hp.0 s -P bAr Ccpsh ee i Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrumentAwas acknowledged before"me this day of /6-QL , 20) 4 , by C Y day of /JGC, , 20 / 6{ , by /4444y M cU eillG , who is pgrsonally known to �IOc� rli L p / / p ✓ , who is Rersonally known to me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: 6044- • ...**.........**.... APPROVED BY (Revised02/24/2014) Cristobal Ortiz NOTARY PUBUC STATE OF FLORIDA FF920230 identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Plans Examiner Cristnhai Ortiz NOTARY PUBLIC STATE OF FLORIDA Commit FF920230 Expires 11/13/2019 Zoning Structural Review Clerk THIS INSTRUMENT PREPARED BY AND RETURN TO: RICHARD A. GOLDEN, ESQ. KRAMER & GOLDEN, P.A. 11900 Biscayne Blvd, Suite 618 North Miami, Florida 33181 718-92BH olFC. 15T62PG2519 RE WARRANTY DEED (Ind. - Ind) (Statutory Form -Section 689.02 F.S.) This Indenture, made this 22nd day of Del THOMAS GUNNAR HEDENQUIST and whose post office address is 13390 N.E. MIAMI hereinafter called the Grantor*, and SCOTT E. PERWIN and AMY J. MCCL whose post office address is 800 N.E. 95TH STREET, MIAMI WITNESSETH: That said grantor, for and in cons good and valuable consideration to said grantor in hand paid granted, bargained and sold to the grantee, and grantee's heiri being in Dade County, Florida, to wit: Property Folio No.: 11-3206-041-0010 LOT 1, BLOCK 1, JONI'HEIGHTS, ;ACC() PLAT BOOK 96 AT PAGE 23 OF THE P1 Subject to restrictions, reservations, easements an reimpose same, zoning ordinances, and taxes for the current Said grantor does hereby fully warrant the title to s _persons whomsoever. *"Grantor" and "grantee" are In Witness Whereof, Grantor as hereunto SI ' gne., s> -led and d>' : ed in our presen ,� •', .e namel/(. /� -�j 7777..... Signal of Witness (402,0e e a r- l lCC r0(9 Print/Type name of Witness STATE OF FLORIDA. COUNTY OF Dade The foregoing instrument was adtnowiedged GUNNAR HEDENQUIST and ANHEtJ INKERI HEDENQ has produced DRIVER'S UCENSES as identification and who . * '' 't L) Stale of Florida At ,buy Expires 30 1, 'C r `TAit'IIj NTI (CATION NUMBER ORMATION TIN 0 262-21-3242 11N 0 585-46.8888 f SCOTT E. PERWIN AMY J. MCCLELIAN t #2R:i 1.6 1!.« $ *' .s ' 4 i3� 3a C3+`SITZ,E 133_7. 4.33 [G"TX 1.00 `.rialt k (Mir CLC ' xt 4411', ember, 1992, between ANNELI INKERI HEDENQUIST, HIS WIFE COURT, NORTH MIAMI, FLORIDA 33161 LLAN, HIS WIFE SHORES, FLORIDA 33138. hereinafter called the grantee*. deration of the sum MIEN AND NO/100 ($10.1)0) Dollars, and other by said grantee, the receipt whereof is hereby acknowledged, has and assigns forever, the fotlowing described land, situate, lying and RDING TO THE PLAT THEREOF, AS RECORDED. IN BLIC. RECORDS OF DADE COUNTY, FLORIDA. d Gmitatkms of record, 11 any, provided that this shoo not serve to year and subsequent years. aid land, and will defend that same against the lawful claims of all sed for singular or plural, as context requires. grantor's hand and seal the day and year first above written. .40 THOMAS G`iUNNAR HEDEN • %'ST ANNELI INKERI HEDENQUIST before me This =22nd day of Decembers, 1992. by THOMAS UIST. HIS WIFE, who is personaly known to me or who did take an oath. otary Public. Commission No. secoroea or ors tam Mom War Or LADE couwty. ft:Oe,DA. eeCOID 'Eef"ED Qerk of Circuit & County Cwlrts i f me of Notary typed, printed or stamped) Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ISSUED: 06/19/2016 CERTIFIED ROOFING CONTRACTOR HERRON, DONNIE S J & K ROOFING:I, Mfl CCC058051 IS CERTIFIED under the provisions of Ch.489 FS. Expiration date : AUG 31, 2018 L1606190000909 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS.... Expiration date: AUG 31, 2018 HERRON, DONNIE S — J & K ROOFING INC 2010 SHERMAN ST HOLLYWOQQ ZF ISSUED: 06/19/2016 004493 DISPLAY AS REQUIRED BY LAW Local Business Tax Receipt Miami—Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY 4247763 BUSINESS NAME/LOCATION J & K ROOFING INC DOING BUS IN DADE CO MIAMI FL 33000 OWNER 1 & K ROOFING INC Worker(s) 5 RECEIPT NO. RENEWAL 4434908 SEQ # L1606190000909 LBT EXPIRES. SEPTEMBER 3Q, 2017 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC. TYPE OF BUSINESS 196 SPECIALTY BUILDING CONTRACTOR CCC058051 PAYMENT RECEIVED BY TAX COLLECTOR $75.00 07/12/2016 CHECK21-16-083679 This Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is nota license, permit, or a certification of the holders qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles - Miami -Dade Code Sec 8a-276. ACQRQ.. CERTIFICATE OF LIABILITY INSURANCE 11 /14� 016 PRODUCER PTS Insurance 7735 NW 146 Street C-100 Miami Lakes, Fl 33016 305-818-9544 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND ALTER THE COVERAGE AFFORDED BY THE POLICIES OR BELOW. INSURERSAFFORDINGCOVERAGE NAIL# INSURED J & R Roofing Inc 2010 Sherman Street Hollywood, FL 33020 19549619879 INSURER Pc Watford Specialty Ins Co 15824 INSURER B LIABIUTY COMMERCIAL GENERAL LIABILITY INSURER C: INSURER D: EACH OCCURRENCE INSURER E COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDMONS OF SUCH POLICIES. AGGREGATE UNITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ITIOIC ww-I. NERD TYPF(F INCIIRAN(:F POUCYNUMBER POLICY EFFECTIVE nATF/MM/nnIYYl POLICY EXPIRATION nATFRAWonrm LIMITS GENERAL LIABIUTY COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1.000.000 PREMISE Eaaooc ure cel S 100.000 X MED DTP (Any one person) $ 5.000 �CLAIMSMADE fl OCCUR A i. S5000 DED PD PAL105367401R 11/15/16 11/15/17 PERSONAL &ADV INJURY $ 1.000.000 GENERAL AGGREGATE $ 2.000.000 PRODUCTS - COMP/OP AGG $ 2.000.000 GEN'LAGGREGATE LIMIT APPLES PER jJPOLICY I , PIFrTRO- I J LOC AUTOMOBILE LUIBIUTY ANYAUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNEDAUfOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ _ ..— BODILY INJURY (Peracddent) $ _ PROPERTY DAMAGE (Peracddent) ....- $ _ GARAGE UABILOY ANYAUTO AUTO ONLY - EA ACCIDENT EA ACC $ OTHER THAN AUTOONLY: AGG $ EXCESSAJWIREUALIABLITY EACH OCCURRENCE $ AGGREGATE �...... $ DOCCUR CLNMSMADE mi......,RETENTION $ DEDUCTIBLE $ WORKERSCOMPENSATIONAND EMPLOYERS ANY OFFICER/MEMBER dyesSPE PROPRIETOR/PARTNER/EXECUTIVE CIAL LWBIUTY EXCLUDED? PROVISIONS below STA IU: Tr1RY1 NaR t IOFRTH- EL EACH ACCIDENT $ EL DISEASE - EA EMPLOYEE $ EL DISEASE - POLICY LIMIT $ OTHER DESCRIPTION Roofing OF OPERATIONS/ LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS Operation CERTIFICATE HOLDER CANCEL Miami Shores 10050 NE 2nd Ave Miami Shores, Fl 33138 305-795-2204 305-756-8972 (F) 1 SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MNL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBUGATION OR UABIUTY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES AUTHORIZED REPRESENTA ACORD25 (2001/08) ® ACORD CORPORATION 1988 • CERTIFICATE OF LIABILITY INSURANCEI te • 1/4/2016 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691or • (727) 938-5562 This Certificate is issued as a matter of information only and confers no rigs upon the Certificate Holder. This Certificate does not amend, extend alter the coverage afforded by the polldes below. Insurers Affording Coverage NAIL # Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N.: Holiday, FL 34691 Insurer A: Lion Insurance Company 11075 Insurer B: Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respell to which this certificate may be issued or may pertain. the insurance afforded by the policies described herein is subject to all the term. exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid dams INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL LIABILITY Commercial General Liability Each Occurrence $ Dame to rented premises (EA occurrence) 8 Claims Made Occur General Med Exp $ Personal Adv Injury 8 aggregate limit applies per General Aggregate $ J Policy ❑ Pitied LOC Products - Comp/Op Agg $ AUTOMOBILE LIABILITY Any Auto All Owned Autos Scheduled Autos Fared Autos Non -Owned Autos Combined Single Unit (EA Acddent) 8 Bodily Injury (Per Person) $ — Bodily Injury (Per Accident) $ Property Damage (Per Accident) $ EXCESS/UMBRELLA LIABILITY ❑ Claims Made Each occ1RenCe Atgesate ROccur Deductible A Workers Compensation and Employers' Liability Any p oprietodpartneriexecutive officer/member excluded? NO If Yes. describe under special provisions below. WC 71949 01/01/2016 01/01/2017 X1 �WC � I ' OT ER E.L Each Accident 81,000.000 E.L. Disease - Ea Employee 81.000.000 E.L. Disease - Policy Limits $1.000.000 Other Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616 Descriptions of Operations/LocationsNehiclesIExclusions added by Endorsement/Special Provisions: Client ID: 92-68-239 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are (eased t0 the following "Client Company': 3 & K Roofing, Inc Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(:;, while worldrg in: FL Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 01-13-15 (TLD)REISSUE 01-04-16 (AF) Begin Date 2/20/2014 CERTIFICATE HOLDER CANCELLATION VILLAGE OF MIAMI SHORES 10050 NE 2ND AVE MIAMI WORM. til.. W1* Should any of the above described policies be cancelled before the expiration date thereof. the issuing insurer will endeavor to nail 30 days written notice to the certificate holder named to the left, but failure to do so shall Impose no obligation or liability of any kind upon the Insurer. its agents or representatives. .t 1 LICENSED AND INSURED 2010 Sherman Street Hollywood, Florida 33020 ROOFING SScud Qoaida Over 30 LICENSE # CC -C058051 954-961-7663 954-961-9879 Fax 954-925-8015 Submitted To Job Name Date Mc ("JP tia0 11-111-g Street kV aSi-as Si Street m c 3,15- Phone 1 53 _q 76/7 City, St. & ip Mn ; amI. sLe reS City, St. & Zip Phone 2 Legal �- Lot Blk Sub Tax Folio# ALL ROOFS TO BE DONE AS FOLLOWS ❑ SLOPE ROOF FLAT ROOF ill tear off entire existing slope Roof down to deck or smoot wo . able surface. WILL RENAIL DECKING TO MEET EXIS G CODE. Remove all related roofing debris from pr . ises. Will tear off entire existing flat roof down to deck or smooth workable surface. WILL RENAIL DECKING TO MEET EXISTING CODE. Remove all related roofing debris from premises. Replace any necessary rotten wood, I no LF, or Sq. ft for plywood free. 1" per ft. tthhereafter. Replace a necessary wood, • LF, or Sq. ft • r plywood free. - rft. thereafter. el Will apply 1 ply of 7-' basesheet anchored to the deck Will apply 30 Ib. p . ium felt, anchored to the d - k according to local building code. Will instal : I new metal flashin. :nd lead stacks. USING HOT ASPHALT, MOP A 36 INCH WI l • STRIP OF 30 LB. FELT VERTICALLY AND A 16 INCH ) ID ALV. VALLEY METAL IN ALL VALLEYS. Will NAIL fiberglass shing . with ring shanks according to local building code. Using HOT ASPHALT, will mop a plys of fiberglass felts to said basesheet. Install all new metal flashing and lead stacks. * WA.A.e- 3K 3 OU rt Arx. Using HOT ASPHALT mop 1 ply fiberglass cap sheet to said fiberglass nails (choice of brand & c• •r) �• , • A ' • nib - 1 p1 ' OP P Manufacturer arranty on shingles. . sal. fib- • las elt. 11 '\ it floo . co • w o • • t h - : r I - , We hereby propose to furnish labor and materials - complete in accordance with the above specifications, for the sum of dollars ($L4d c) ) with payment to be made as follows: Alt SCOO Dc'>![ai.5. Bal LLPdai 0 Cfrl-,(, No carpentry work, woo ork or painting less specifically stated in this contract. In the event payment is not make as stated in payment schedule, All fees incurred in collections, such as, but not limited to, attorney fees, court costs and collection agencies, are to be paid by signer or owner. COVERAGE T The roof applied to the building described above is guaranteed for 1 et3 years from the date of completion upon final payment in full. This guarantee is TRANSFERABLE AT NO CHARGE to new owners of the property. Under this guarantee, the roofing contractor will, at its own expense, make any repairs necessary to correct roof leaks resulting from the following causes: 1. Failure of roofing felts or base flashing resulting from usual and ordinary effects of wear and weather, 2. Poor workmanship of roofing contractor In applying roofing and flashing materials. EXCLUSIONS � t d t�5 OC.i10 3C � � �� This guarantee does not cover: 1. Leaks or other damage caused by: Method of Payment: CHECK CASH ❑MONEY ORDER 4X CREDIT CARD �f +�0 a. Natural disasters, including but not limited to floods, lightning, hurricanes, hail, windstorms, earthquakes, tornados, dry rot, etc. b. Structural failures such as cracks in decks, walls, partitions, foundations, windows, stoppage of roof drains or gutters, etc. c. Changes in the original principal usage to which of the building, unless approved by the contractor in advance in writing. d, Erection or construction of any additional installation on or through the roofing felt after the date of completion. e. Roof or flashing repairs by others, painting or coating without approval. -., f. Riots or vandalism. g. Termites or other insects. h. Penetration of the roofing from beneath by rising nails. 2. Damage to the building or it's contents, roof insulation, roof deck or other base over which roofing felt is applied. ACTION $GomOO Or ��li � i In the event leaks roofing should occur, owner all notify ontractor promptly. Contractor will inspect the roof, and if cause of leak is within the coverage as stated above, the contractor will arrang r repairs to be made at no cost to the owner. If cause of leak is not covered, contractor will not be responsible for cost of any repairs. In the event leaks are not covered under the terms of this guarantee, a service charge will be invoiced to,the owner. The guarantee will become null and void if payment of the service charge is not made within 30 days of the billing date. WE MAKE NO GUARANTEES OF ANY KIND, EXPRESSED OR IMPLIED, EXCEPT AS STATED HEREIN. ACCEPTANCE OF PROPOSAL: The above prices, specifications and are hereby accepted. You are (I!) n T)UR (O er and conditions are satisfactory authorized to do the work as specified. Payment will be made as outlined 1 wood clause. SIGNATURE (Owner) above. understand DATE \ .," \e �• 16 th r ed Signature Orz, f"4 , 0100% RECYCLABLE CREATIVE GRAPHICS • 954-962-8868 J&K Roofing/ Proposa Master Permit No. ROOF ASSEMBNES AND ROOFTOP STRUCTURES Building Code 5th Edition (20 High-Yaloclty Hurricane Zone Uniform Perm Section A (General information) OSA Contractors Nana 072")( Job Address LD D )0E- Low Slope O Asphaltic Shingles O New roof 0 Repair Low Slope Root Area (SF) a 0 0 ROOF CATEGORY O Mechanically Fastened Tile O Metal PaneVShingles b. Prescriptive BUR -RAS 150 ROOF TYPE 0 Maintenance 110 RemoTh g ROOF SYSTEM INFORMATION Steep Sloped Roof AREA (SSF) v.Total (SF 'LO 0 A 04,7 O Mortar/Adhesive Set Tiles? O Wood Shingles/Shakes Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflowand overflow drains. Includeimen- sions of actions and levels, dearly identlfy dimensions of elevated pressure sones a stion of parapets. l_ 1 I_I_ i --i- • • - •- -• • •• • •••• - • • • • •• • • • -• • • • • • • •• • I 1 I 1 1 1 I 1 1 FLORIDA BUILDING COM - ausa Ne, ew X1(2014) . • • ■ • •• • • • • • • • • • - • • •• • -•-• • • • • •••• • • •••i • • • • • • . • I••• • • • �• • 7 1527 1100FASSMOugg AND110016FppS1SVCIVIIIS Rola Bulking Coebah Edition gnu) High-YwooiiY HunInane Zona Uniform Par nit Application Foyer. Section C (Low Slope Application) Fil In specific mot assembly components and >r manufacturer Of a component Is not used, identify as "NA') System i oaurer 6.4 F • Product Approval No.; j = /0),;?. !s' • Design wind Pressures, From RAS 128 or Calculadorw` Pi. 92-2 P2 7l•7 pa /De w'DesignWe tan the specifics maw( *Plo Deck /'©aJ siopt/7"eandma; 171/k And or/Baae Sheet & No. d PIy(sZ Sheet Fastener/Bonding Mated* Top Ply FestenrgAfetedak140-1- f I� Surfacingc Fastener Sparing for AndiovSase Sleet Afl hme:t Rakt -oaeLen. iRows a .oc • Perimeter: !P 'oo ® Lap, i Rows® •ea Comer: le: oa0Lap, aRaws±®•a Number of F Per Insulason Swett Meld.___. Perimeter Comer illuatrate Gonrpormrda Noted and Details as Applicable: �c 'BasF���r iaCoCart Coping, Etc. hrg, bawds Mean Root Height, Parapet Haight, Height of Base Flashing, Component Materiel, Metedal Thickness, Fastener type. Fastener Spacing or Submit Manuiact,rem Details that Comply wit RAS 111 and Chapter 16. Insulation sada Layer: -1A• Base Msulafion Size and Th1E:knew Base Insulation FastenebBmdiq Mareriab 4 J. Je13C k4e . . . Tap inaIadon Layer: Tap baton Size and T1ress: Top Insulation Fastanoi of ding-1tedak Boa Sheets) A No. of PIS* 134ie &Lee+ Ply SWAN & No. of ) PIO Py Shedr-etalrre A" Top p ��Z7 ri 41. . pet Height . •. FT: :. ••r' • . ..1 •.. • • / • . •. 1 • . • • • • . . . • • • • • . • ween • • • 'Height ..• . . . •••• •.. •. •.- .: • FLORIDA OOLONG CODE— INatoeiei , ae. EDITION ND14j MIAMI E COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.2ov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no • change in the applicable building code negatively affecting the performance of this product. •• • TERMINATION of this NOA will occur after the expiration date or if there has been t• ievigion a thartge in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an•endorsemen of any • product, for sales, advertising or any other purposes shall automatically terminate this NQ ,Failure to cpmply • with any section of this NOA shall be cause for termination and removal of NOA. '.... • • • • • • • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade CountykgItgida, and'fA1k3ALed by the expiration date may be displayed in advertising literature. If any portion of the 1114341041 displayed, then it shall be done in its entirety. • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufaot• xier or its ilistiboutors • and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 13-0424.09 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L. Acebo. .• . MIAMI•DADE COUNTY APPROVED .. • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 1 of 16 • . ROOFING SYSTEM APPROVAL Cateeorv: Sub-Cateeorv: Material: Deck Type: Maximum Design Pressure: Roofing BUR Fiberglass Wood -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Description 39.37" (1 meter) ASTM D4601 Type II asphalt impregnated and coated glass mat Wide base sheet. Product GAFGLAS® #75 Base Sheet GAFGLAS® #80 Ultima'' Base Sheet GAFGLAS® FlexPly" 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCap" BUR Mineral Surface Cap Sheet GAFGLAS® Stratavent® Eliminator" Perforated Venting Base Sheet GAFGLAS® Stratavent® Eliminator."( Nailable Venting Base Sheet Ruberoid® SBS Heat - Weld" Smooth Ruberoid® SBS Heat - Weld" 25 Ruberoid® 20 Ruberoid® Mop Smooth MIAMI-DADE COUNTY APPROVED 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 3937" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) wide ASTM D4601 Type II asphalt impregnated and coated, fiberglass base sheet. ASTM D2178 Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. ASTM D2178 ASTM D3909 ASTM D3909 ASTM D4897 ASTM D4897 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6164 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCoteTM Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. • • A nailable, fiberglass base•sheet impregnaed and coated on both sides wit)ra flfalt. Slirfaeed on tht bottom side with minerfl'g%r i!iri1es embeIded in • • •asphaltic coating. • • • • • • • •• • ••••• • •• • • • • • Non -Woven Polyester n'lat.e ed witlreo1 'mer - modified asphalt and smooth surfaced • • Non -Woven Polyester n'iat costed wi}h�xalymer- modified asphalt and smootk'surfaced.• • • SBS modified asphalt base sheet reinfb1 ce With a glass fiber mat. Non -woven polyester mat coated with polymer - modified asphalt and smooth surfaced. NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 2 of 16 • • • • • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product FireOut"" Fire Barrier Coating VersaShield® Fire Resistant Roof Deck Protection Dimensions 5, 55 gallons 350 sq. ft. roll Topcoat® Surface Seal 5 gallons SB APPROVED INSULATIONS: Product Name EnergyGuard"" Polyiso Insulation EnergyGuardm RA Polyiso Insulation EnergyGuardm RN Polyiso Insulation EnergyGuard"' Perlite Roof Insulation EnergyGuard"" Perlite Recover Board EnergyGuardm RA Composite Polyiso Insulation Securock® Gypsum -Fiber Roof Board Structodek® High Density Fiber Board DensDeck® Roof Board MIAMI-DADE COUNTY APPROVED Test Specification Product Description Proprietary Low VOC, water based fire barrier coating. ASTM D226 Non -Asphaltic Fiberglass -Based Underlayment. ASTM D6083 Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board. Perlite recover board Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation Gypsum roof board High density fiber board Gypsum board Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF United States Gypsum Corp. Blue Ridge Iaibeslioard, Inc. • G2thgi Paci13C iyflsum LLC• . . .• .... . . . .. . •. • • •• ..•. . • •. .. •••• • • • . . . • . • . . •• . • •... . . • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 3 of 16 • • . • • • . • . . APPROVED FASTENERS: Fastener Product Number Name 1. Drill-Tec'm #12 Fastener 2. Drill -Tec" #14 Fastener 3. Drill -Tec" XHD Fastener 4. Drill -Tec" ASAP 3S 5. Drill -Tec" 3" Steel Plate 6. Drill -Tec" 3" Standard Steel Plate 7. Drill -Tec" AccuTrac® Flat Plate 8. Drill -Tec" AccuTraca Recessed Plate MIAMI•DADE COUNTY APPROVED TABLE 3 Product Description Insulation fastener for steel, wood & concrete decks. Insulation fastener for steel, wood & concrete decks. Carbon steel extra heavy duty fastener used in steel decks. Drill -Tec" #12 Fastener with Drill -Tec" 3" Standard Steel Plate Round galvalume stress plate used with Drill -Tec" fasteners. Round galvalume plated steel stress plate with reinforced ribs for use with Drill -Tec" fasteners. AZ -SS aluminized steel plate for use with Drill -Tec" #12 Fastener, Drill -Tec" #14 Fastener and Drill -Tec" #15 Fastener. Galvalume Steel plate for use with Drill -Tec" fasteners. Manufacturer Dimensions (With Current NOA) various GAF various GAF Various GAF Various GAF 3" round GAF 3" round GAF 3" square GAF 3" square GAF .. . • . .. • .. . •.• • .. . •... •. • . . • .• .... . .. • . .... • .... .... • . • • . .• . • • • ..• •••• • • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 4 of 16 EVIDENCE SUBMITTED: Test Aeencv Factory Mutual Research Corp. UL LLC PRI Construction Materials Technologies, LLC IRT of S. Fl. Trinity I ERD MIAMI-DADE COUNTY APPROVED i a Test Identifier J.I.2B8A4.AM J.I. 3B9Q 1.AM J.I. ODOA8.AM J.I. OD1A8.AM J.I.0Y9Q5.AM 3029832 R1306 GAF -012-02-02 GAF -020-02-01 GAF -082-02-01 GAF -084-02-01 GAF -270-02-02 GAF-276-02-01Rev GAF -276-02-02 GAF -306-02-01 GAF -314-02-01 GAF -315-02-01 GAF -369-02-01 GAF -417-02-01 GAF -464-02-01 GAF -499-02-01 GAF -500-02-01 02-005 02-014 G30250.02.10 -3-R1 G31360.03.10 G33470.01.11 G34140.04.11-2 G34140.04.11-4 G34140.04.11-5 G34140.04.11 -5-R1 G40630.01.14 -2A-1 G43610.01.14 G6850.08.07-1 G30250.02.10 -3-R1 Description 4470 4470 4470 4470 4470 4470 UL 790 ASTM D4977 ASTM D4977 ASTM D6083 ASTM D6083 ASTM D226 ASTM D6083 ASTM D226 ASTM E96 ASTM D2178 ASTM D2178 ASTM C1289 ASTM C1289 ASTM C1289 ASTM D6083 ASTM D6083 TAS 114 TAS 114 ASTM D3909 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6401 ASTM D4897 ASTM D4891 .0. ASTM D6164 • • • ASTM D3904 . ASTM D3909 • • • • ASTM D3909••••• • • • • Date 07/02/97 01/08/98 07/09/99 07/29/94 04/01/98 05/11/07 07/22/13 11/06/01 02/01/02 05/07/06 05/09/06 11/15/10 12/16/10 11/15/10 07/07/11 08/23/11 08/23/11 10/22/12 05/28/13 10/22/12 03/12/14 03/12/14 01/18/02 03/22/02 11/26/12 03/31/10 11/16/11 04/25/11 04/25/11 • 04/25/11 :".1W18/13 • •.0%07/14 .. • M/22/14 •. 4/13/07: •11/26/12 •••• • • •••• • •• • • • • •• • •••• • • • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 5 of 16 • • • • • • • . • APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection or (optional) Securock® Gypsum Fiber Roof Board. Anchor sheet: Fastening Options: MIAMI-DADE COUNTY APPROVED GAFGLAS® #80 Ultima" Base Sheet, GAFGLAS® Stratavent® Eliminator' Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat -Weld" Smooth or Ruberoid® Heat - Weld' 25 base sheet mechanically fastened as described below; GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf. See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® F1exP1yTM 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecTM #12 Fastener, Drill -Tee' #14 Fastener and Drill -Tee' 3" Steel Plate, Drill -Tec' AccuTrac® Flat Plate or Drill-Tec'M AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #7) GAFGLAS® FlexPly'" 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf. See General Limitation #7) GAFGLAS® #80 Ultima'M Base Sheet, Ruberoid® 20, Ruberoid® Mop Smooth, base sheet attached to deck with approved PA" annular ring shank nails and inverted 3".steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing.of.• • 9" o.c. in the center of the membrane. • • • •• •• • • •• (Maximum Design Pressure —60 psf. See General Limitation #'l) • • • ••. • . *� ... GAFGLAS® #75 Base Sheet or any of above anchor sheets attachedte deck with Drill -Tee • #12 Fastener, Drill-TecTh #14 Fastener and Drill -Tec 3" Steel Pla&P,'Drill-Tec •AccuTr • • Flat Plate or Drill -Tech AccuTrac® Recessed Plate 12" o.c. in 4 4-811v.s.:One row is in the 2" side.lap. The other rows are equally spaced approximately 9" o.c. in the field otAe sheet. • • (Maximum Design Pressure —60 psf. See General Limitation #S) • ; • Any of above anchor sheets attached to deck approved annular ring shapk nail: and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" 1I ttatgered in two rows 9" in the field. (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 6 of 16 . Fastening Options: GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" (Continued) #12 Fastener or Drill-TecT" #14 Fastener and 3" Drill-TecT" 3" Steel Plate, Drill -Tec"" AccuTrac® Flat Plate or Drill-TecT`" AccuTrac® Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'" Polyiso Insulation, EnergyGuardT" RA Polyiso Insulation, EnergyGuardT" RA Composite Polyiso Insulation Minimum 1" thick N/A N/A EnergyGuardTM Perlite Recover Board Minimum %" thick N/A N/A EnergyGuardT" Perlite Roof Insulation Minimum 3A<" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavent® EliminatorT' Perforated Venting Base Sheet laid dry or a layer of EnergyGuardT" Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Base Sheet: Ply Sheet: Cap Sheet: Surfacing: Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima'" Base Sheet, GAFGLAS® Stratavent® EliminatorT" Perforated Venting Base Sheet, Ruberoid® Mop Smooth, Ruberoid® 20, Ruberoid® SBS Heat-WeIdTM Smooth or Ruberoid® SBS Heat-Weldh 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation #4). One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex Ply"' 6 sheet or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40lbs./sq.• • • • • • (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet.Qr. UAFGLAS®.. • • EnergyCapT" BUR Mineral Surfaced Cap Sheet adhered in a fullreo}ng of approved • • asphalt applied within the EVT range and at a rate of 20-401bs./§q! • • • ; • . • . • • •••• • •• Optional on granular surfaced membranes; required for smooth membranes. Chosen,: • • • components must be applied according to manufacturer's application inshtretions. Al? •: • coatings must be listed within a current NOA. . • • ••. 1. Gravel or slag applied at 400 lbs./sq. and 300 1bs./sc respcctivelia•a flood coal'' •• of approved asphalt at 60 lbs./sq. • • •• • •••• • • 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. •.. ••• Maximum Design Pressure: See Fastening Options. MIAMI-DADE COUNTY APPROVED NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 7 of 16 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B: Optional base sheet laid dry; base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardm Polyiso Insulation, EnergyGuard"" RA Polyiso Insulation Minimum 1.3" thick 1, 2, 3 or 4 1:3 ft2 EnergyGuard"' RN Polyiso Insulation Minimum 1.4" thick 1, 2, 3 or 4 1:3 ft2 EnergyGuard"' RA Composite Polyiso Insulation Minimum 1.5 thick 3 1:3 ft2 EnergyGuardm Perlite Roof Insulation Minimum'/." thick 1, 2, 7 or 8 1:2 ft2 Structodek® High Density Fiberboard Minimum 1" thick 1, 2, 7 or 8 1:4 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). GAF requires either a ply of GAFGLAS® Stratavent® Eliminator"' Perforated Venting Base Sheet laid dry or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulations listed for Base Layer, above. N/A • • NIA Structodek® High Density Fiberboard, EnergyGuard"' Perlite Recover Board •• . . •• b •• . • . • Minimum %" thick N/A • • • • N/A • • • • • • Note: Optional top layer of insulation shall be adhered with approved asphalt within ,he4 yT ram and at a• rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for in%hhttion attacliment. Composite insulation boards used as a top layer shall be installed with the polyisocya$LlMd face doWiL . Fire Barrier: FireOutn" Fire Barrier Coating, VersaShield® Fire Resistant Roof Dpek Irptection of Securock"' •, (optional) Gypsum Fiber Roof Board. • • . . • • • • •.• • ..•. • • • . •• MIAMI-DADE COUNTY APPROVED NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 8 of 16 Base Sheet: Ply Sheet: Cap Sheet: Surfacing: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima- Base Sheet, GAFGLAS® Ply 4, GAFGLAS® F1exPly" 6, GAFGLAS® Stratavent® Eliminator's Perforated Venting Base Sheet laid dry, Ruberoid® Mop Smooth or Ruberoid® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). Two or more plies of GAFGLAS® Ply 4, GAFGLAS® F1exPly M 6 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See specification number for appropriate number of plies). (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapn" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See GAF application instructions for approved method of installation). Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation #7) MIAMI-DADE COUNTY APPROVED • • • • . . . ..• .. • •• • • • .. • • ...... • • • • . ..• . .... • .. • . ...• 1 . • •. •. •..• • • . • • • . • . . • • • •• . ..• ••••• .. . NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 9 of 16 Membrane Type: Deck Type 1I: Deck Description: System Type C: BUR Wood, Insulated 19/32" or greater plywood or wood plank One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard"' RN Polyiso Insulation, EnergyGuard'" Polyiso Insulation, EnergyGuard"" RA Polyiso Insulation Minimum 1.3" thick N/A N/A EnergyGuard"" Polyiso Insulation Minimum 1.4" thick EnergyGuare RA Composite Polyiso Insulation Minimum 1.5" thick EnergyGuard"" Perlite Recover Board Minimum 3/4" thick Structodek® High Density Fiber Board Minimum 1" thick N/A N/A N/A N/A N/A N/A N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent® Eliminator"' Perforated Venting Base Sheet laid dry or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Top Insulation Layer Insulation Fasteners ::: 3) . • '4;•• EnergyGuard"" Polyiso Insulation, EnergyGuard"" RA Polyiso Insulation Minimum 1.3" thick EnergyGuard"' RN Polyiso Insulation Minimum 1.4" thick EnergyGuard"" RA Composite Polyiso Insulation Minimum 1.5 thick EnergyGuard"" Perlite Roof Insulation Minimum 3/4" thick Structodek® High Density Fiber Board Minimum 1" thick MIAMI-DADE COUNTY APPROVED 1,2or3' . . .. .. 3 . • . •• • . • 1,2,7or'g • 1, 2, 7 or 8 . fastener :"ffehsity/ft .... . ••. • • • x••1:3 ft2 .. . • • •. . • "1:3 ft2 . • ▪ .... • 1:3 ft2 '. .a.••. . . . • •' • • l :2 ft2* .. • 1:4 ft2 NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 10 of 16 • Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent® Eliminator"" Perforated laid dry or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Fire Barrier: FireOut'M Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection or (optional) Securockn' Gypsum Fiber Roof Board. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima" Base Sheet, GAFGLAS® Ply 4, GAFGLAS FlexP1yTM 6, GAFGLAS® Stratavent® EliminatorTM Perforated Venting Base Sheet laid dry, Ruberoid® Mop Smooth or Ruberoid® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; see General Limitation #4. Ply Sheet: Two or more plies of GAFGLAS® Ply 4, GAFGLAS® F1exP1yTM 6 ply sheet or GAFGLAS® #80 UltimaTM Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at l to 1.5 gal./sq. .....• Maximum Design Pressure: • � • •• •• • -45 psf. (See General Limitation #7) MIAMI•DADE COUNTY APPROVED • •• • •• • • • • •• •••• •• • . • • • •••• • .. •••••• • • ••• •• . • • • • • •• •• • •••• • • • . • . •••• • •• NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 11 of 16 • • • •••••• • • • • • • • • Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type D: Insulation and Base sheet simultaneously All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard"' Polyiso Insulation, EnergyGuard"' RA Polyiso Insulation Minimum 1.3" thick N/A N/A Structodek® High Density Fiber Board Minimum 1" thick N/A N/A Note: Insulation shall have preliminary attachment, prior to the installation of the base sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation, optional thermal barrier (when present) and base sheet shall be simultaneously fastened. See base sheet below for fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Fire Barrier: FireOut"' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection or (optional) Securock' Gypsum Fiber Roof Board. Base Sheet: Fastening Options: MIAMI DADE COUNTY APPROVED Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima"' Base Sheet, GAFGLAS® Stratavent® Eliminator"' Nailable Venting Base Sheet or Ruberoid® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Drill -Tec"' #12 Fastener or Drill -Tec"' #14 Fastener and Drill -Tec"' 3" Steel elate:Dri11- Tec"' AccuTrac® Flat Plate or Drill -Tec"' AccuTrac® Recessed Pete is installed through the . • base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lay. TIT 0 tivt rows....:. are equally spaced approximately 12" o.c. in the field of the sheet: .. : .. •.... • (Maximum Design Pressure —45 psi See General Limitation #7).... . • • • • • • , •..• ..... Drill -Tec"' #12 Fastener or Drill-Tece` #14 Fastener and Drill -Tec'"• 'f steel P1 t Drill- • • Tec"' AccuTrac® Flat Plate or Drill -Tec"' AccuTrac® Recessed Plgtrisjhstalled.through tht • • base sheet and insulation in 4 rows 8" o.c. One row is in the 2" sidalap.The other 3 rows • • are equally spaced approximately 9" o.c. in the field of the sheet. • (Maximum Design Pressure —75 psf. See General Limitation #7): . • .. • ••.. GAFGLAS® #80 Ultima"' Base Sheet, Ruberoid® 20, Ruberoid® Mop Smooth, bate sheet attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 12 of 16 • • • Fastening Options: Drill-Tec`" #12 Fastener and Drill-Tec' #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill- (Continued) Tece" AccuTrac Flat Plate or Drill-Tec"' AccuTrac® Recessed Plate in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #7) Ply Sheet: One or more plies GAFGLAS® Ply 4, GAFGLAS® FIexP1yTM 6 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCap"' BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at lto 1.5 gal./sq. Maximum Design Pressure: See Fastening Options MIAMI-DADE COUNTY APPROVED • • . • •• • • •..•.• • •• • •• • • • •.•• •• • • • •• • • •••• • •• • • .• •• •••• • • •••• • • • • • • • • • • •• .• • .••• • . • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 13 of 16 • • • •...•. • • • • • • • • • Membrane Type: Deck Type 1: Deck Description: BUR Wood, Non -insulated 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: (optional) Base sheet: Fastening Options: FireOut"Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection or Securockm Gypsum Fiber Roof Board. GAFGLAS® #80 Ultima"Base Sheet, Stratavent® Elim'ator Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat -Weld"' Smooth or Ruberoid® SBS Heat -Weld'" 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4, GAFGLAS® F1exPly 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psi. See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® F1exPly 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec"' #12 Fastener or Drill -Tec"' #14 and Drill - Tec"' 3" Steel Plate, Drill -Tec'" AccuTrac® Flat Plate or Drill -Tec"' AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the shee1 - (Maximum Design Pressure —45 psf GAFGLAS® Flex Ply 6, GAFGL to deck with approved annular rin eneral ' itati #7) #75 Base Sheet or ps at a fastener siting of 9" o.c. of above base sheets a nails and at the 4" ap staggered and in two rows 9" o.c. m e field. ••. • • aximum # esign ensure 52.5 ps ee ever' un ; , 11717)• ....... GAFGLAS® #80 Ultima Base Sheet, Ruberoid® 20, Ruberoidatili Smooth, base shit • • • attached to deck with approved Ph" annular ring shank nails and inverted 3f steer plate.at•a . fastener spacing of 9" o.c. at the 4" lap and in two rows stagerilim ji a fasts ies spacing of • • g • 9" o.c. in the center of the membrane. • (Maximum Design Pressure —60 psi:See General Limitation #T): •: • ' . GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck wwf thil1-Tei #12 Fastener or Drill -Tec"" #14 Fastener and Drill -Tec"' 3" Steel Plate, Driu=T@8: • AccuTrac® Flat Plate or Drill -Tec'" AccuTrac® Recessed Plate 12" o.c. in 4 r5ws. °One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —6014 See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec'" insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 14 of 16 • • Fastening Options: GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec" (Continued) #12 Fastener or Drill-Tec #14 Fastener and Drill-Tem 3" Steel Plate, Drill-Tec"" AccuTrac® Flat Plate or Drill-Teem AccuTrac® Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #7) Ply Sheet: One or more of GAFGLAS® Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full moppingirn of pmved s halt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCap m BUR Mineral Surfaced Cap Sheet adhered in a full mapping.stf approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. 2. Topcoat® Surface Seal SB applied at lto 1.5 gal./sq. Maximum Design Pressure: See Fastening Options M IAMI-DADE COUNTY APPROVED • . . . • .. • • .• ..0.0. . •. • • . • • • . • . •• • • • • • •••• •• •• •••... • • ..• .. ..••0. 0 • • • • • • . .. • •••• • •... • • • .•00 . . • NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 15 of 16 • • ...••• • • ..0000 • • • • • . • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply"' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" DensDeck"' Roof Board or '/2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fasteper spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered 4&rchytect, oraegisTered • Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdraarresistaaie vplue ' . taken from Testing Application Standards TAS 105 and calculations in compliance witk4Zgofing Applitfition •••••• • Standard RAS 117. • 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements.df Nose areas • r.gEtener• densities shall be increased for both insulation and base sheet as calculated in compliant wilt Roofing Application • • • Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Proiggiiphal Engineer; • Registered Architect, or Registered Roof Consultant (When this limitation is specifically Teferred'within ' • this NOA, General Limitation #9 will not be applicable.) •• 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination:d esigns shall cqp form to. • •Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 13-1022.15 Expiration Date: 11/04/18 Approval Date: 11/06/14 Page 16 of 16 10/1812016 ONLINE CERTIFICATIONS DIRECTORY paae Bottom TGFU.R14153- Roofing Systems TGFU.R14153 Roofing Systems Roofing Systems See General Information for Roofina Systems GAF 1 CAMPUS DR PARSIPPANY, NI 07054 USA R14153 "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 -in. thidc (minimum) gypsum board or 1/4 -in. thidc (minimum) Georgia-Padfic Gypsum LLC "DensDedci- Roofboard," "DensDeck Prime® Roofboard" or "DensDedc DuraGuard"" Roofboard" may be used In any existing noncombustible deck Classification. When this Is done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Padfic Gypsum LLC "DensDedc® Roofboard," "DensDedc Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" are to offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overiayment board. Multiple plies of "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "Tri -Ply® Ply 6" may be adhered to Georgia-Padfic Gypsum LLC "DensDeck ® Roofboard, "DensDeck Prime® Roofboard" or "DensDedc DuraGuard " Roofboard" in hot roofing asphalt. "EnergyGuardTM Ultra" is an acceptable alternate to "EnergyGuard"' RF In any applicable Classification. "GAF Stratavent® EliminatorTM Venting Base Sheet (Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLAS® Perlite Insulation" may be utilized as a cover board over "EnergyGuard"' RF" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications indude "EnergyGuard'" EPS Insulation". Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturt&iliStpllation instructions (excluding LRF Adhesive 0) in any applicable Non -Combustible Roof Deck Classifications.• . • • • • • • • References to glass fiber insulation indude "EnergyGuard Fiberglass Insulation". •' ' • • • •• •••••• •••••• • •• "EnergyGuard"" Tapered" is an acceptable altemate to "EnergyGuard""" in any applicable aassification. ' • • • •• • • •• •• ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT • • •• •• •••• • ••• • • Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet", or "GA #80•l1L'IIAt4") Is a suitable alternate for Type Gi asphalt glass fiber ply sheet ("GAFGLAS® Ply 4" or "Tri -Ply® Ply 4", or "GAF�Ply 6")•iMtHe Class V, If: or C roof systems indicated below.• • • • • • • ' • • • •• •••••• •The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Strativent® Eiminatiory'•Venting se • Sheet (Perforated)" or "GAF Stratavent® EliminatorTM Venting Base Sheet (Nailable)." Perforated base sheens to be loose Paid or fully a Ned• • with hot roofing asphalt and nallable base sheets are to be mechanically attached granule side down. ' • • • • • • • ' •• • • • As an option Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or "GAFGLAS® #80 ULTIMA" or "GAF Stratavent® EliminatorT" Venting Base Sheet (Nallable)" may be substituted for Type G1 asphalt glass fiber ply sheet ("GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, alt insulations may be hot mopped or mechanically fastened. "GAFGLAS® Flashing" or "Ruberoid®" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this indudes "GAFTEMP PEtMALITE®" or any other UL Classified periite insulation. Crushed stone or slag are suitable altemates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be induded as a deck In the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of Y: -in. minimum thick gypsum board is an acceptable altemate for minimum insulation over C-15/32 thick roof dedcs. The use of polystyrene Insulation board between minimum /-in. thick periite board and deck with rosin paper (periite/rosin paper/polystyrene/periite) is a suitable altemate for polyisocyanurate board in the following Class A, B or C systems. hdpJ/databaseul.cam/ogi-bin/XYV/templateAJSEXT/1FRAMEIshowpagehiiml7nameRTGFUR141538ocoshorditlRoofirg+Syrsiems&abjid=10 7&d... 1/49 10/18/2016 TGFU.R14153 - Roofing Systems • • ."EnergyGuardTM RA" or "Tapered EnergyGuardTM RA" or "EnergyGuardTM Composite RA' may be substituted for any Atlas Roofing Corp. polyisocyanurate insulation in any of the following Classifications. Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS® #80 Premium Base Sheet' may be used in any of the following systems. "GAFGLAS® Flex Ply 6" and "Tri -Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS® Ply 6". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT® Fireshield MB" at 2Ih to 3-gal/100-ft2. "Ruberoid® Dual Smooth" may be used as an altemate to "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT". "Ruberoid® Mop Smooth 1.5" may be used as an altemate to "Ruberoid® Mop Smooth". Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid® Heat Weld' SBS roofing membrane may be used in lieu of "Ruberoid® Mop" SBS products in any applicable Classification. 1. Deck: C-15/32 Incline: 3 Insulatlon (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type 61 or °GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6" hot mopped. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more piles Type 61 or "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® PIy 6". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet " or "GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet". 3. Deck: NC Indine: 2 Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite, wood fiber/polyisocyanurate composite, phenolic, 2 -in. maximum. Ply Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4', "Tri -Ply® Ply 4° or "GAFGLAS® Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS® EnergyCap " BUR Mineral Surfaced Cap Sheet.• • • • • • •.. • : C-15/32 Inline: 1 • • • • ••• • • • • • • Slip Sheet (Optional): — Red rosin paper, nailed to dedc. ° Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate medranisaily fast tigd I% adhered with. OMG Inc "OlyBond Fastening System" or any UL Classified insulation adhesive. •• • • • • . • • • • Base Sheet: — Ori„ Ga "GABG dc® $75 Basea et" or "Tri -Ply® #75 Base Sheet" (may be nailed). •... Ply Sheet: — On or more plies Type 61 "GAFGLAS PI 4" or "Tri -Ply® PIy 4" or GAFGLAS® . • • • • Cap Sheet: — ne ply y -ral Surface�Cap Sheet" or "Tri -Ply® Mineral SurfabeECap Sheer8r ® "GAFGLAS• EnergyCapTM BUR Mineral Surface Cap Sheet". • ' • Surfacing (Optional): — "TOPCOAT® EnergyCoteTM Elastomeric Coating" applied at a rate of 2-gaCf10f-4. • • • • 5. Deck: NC Inline: 3 • • • • • •• • Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet". Ply Sheet: — One or more plies Type 61 "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet' or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS® EnergyCap " BUR Mineral Surfaced Cap Sheet." • •••- • • • •• • • • • 6. Deck: C-15/32 Inline: 2 Insulation: — One or more layers perlite, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, pertite/urethane composite, phenolic, 1 in. minimum (offset a minimum of 6 -in. from plywood deck joints). Base Sheet: — One or more plies Type G1 or Type G2 or Type G3. Membrane: — One or more plies "Ruberoid® Torch Smooth" or "Ruberoid® Torch Granule" or "Ruberoid® Torch Granule Plus" or "Ruberoid® Mop Smooth" or "Ruberoid® Mop Smooth 1.5" or "Ruberoid® Mop Smooth Plus" or "Ruberoid® Mop Granule" or "Ruberoid® Mop Plus Granule" or "ROOFMatchTM SBS Modified Granular" or "Tri -Ply® SBS Modified Bitumen Membrane" or "ROOFMatchTM APP Modified Granular" or "Tri -Ply® TP -4G" or "Tri -Pty® TP -4" or "Ruberoid® Dual Smooth". Cap Sheet: — Type G3 "GAFGLAS e Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet"or "GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt 7. Deck: C-15/32 Inline: 2 • httpJ/database.d.corn/cgi-binNYV/templatafUSEXf/1FRAME/sinwpage.html?name=TGFU.R1415384cnshorltitlepRoofing+Systems&obji&10133 78d... 2/49 Miami Shores Viitage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI n 33138 , Re: Owner's Name: Alin 7Y/ c 0€ get Property Address: eD O AJ % 9r S+ //4/,,„,,^ 140/10 S Date: Roofing Permit Number: Dear Building Official: 1 f7 cadovN certify that f am not required to retrofit the roof to wall connections of my building because: tilThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00 Pleasivttit proafafad• valorem taxation. ' • •• •• • •. • • • . • •• • o The building was constructed in compliance with the provisions of the Florida Building Code�(FBC) or with.the provis+Qrts; ••.• •. • of 1994 edition of the South Florida Building Code (1994 SFBC) •• • Signature State of Florida County of Dade • • Print Name •• • • . •. • • • ..•• • .• • ••.. • . • .. • :. • • The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this l47 day 4e,C--- .Zoq0. oq Cristobal Oroz NOTARY PUSUC Notary Public, Sate of Florida at Large CIO�u STATE OF FLORIDA Comm# FF920230 Expires 11/13/2019 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than 5300,000.00, and the building was not constricted with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 12/19/2016 Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-041-0010 Property Address: 800 NE 95 ST Miami Shores, FL 33138-2515 Owner SCOTT E PERWIN &W AMY J Mailing Address 800 NE 95 ST MIAMI SHORES, FL 33138-2515 Primary Zone 1400 SGL FAMILY - 3001-3250 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3 / 3 / 0 Floors 1 Living Units 1 Actual Area 3,913 Sq.Ft Living Area 2,733 Sq.Ft Adjusted Area 3,231 Sq.Ft Lot Size 10,453 Sq.Ft Year Built 1974 Assessment Information Year 2016 2015 2014 Land Value $271,632 $251,148 $178,119 Building Value $241,743 $243,617 $239,142 XF Value $28,360 $18,641 $18,802 Market Value $541,735 $513,406 $436,063 Assessed Value $236,752 $235,107 $233,242 Benefits Information Benefit Type 2016 2015 2014 Save Our Homes Cap Assessment Reduction $304,983 $278,299 $202,821 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (.e. County, School Board, City, Regional). Short Legal Description JONI HEIGHTS PB 96-23 LOT 1 BLK 1 LOT SIZE IRREGULAR OR 15762-2519 1292 1 Generated On : 12/19/2016 E3A9 Taxable Value Information Previous Sale 2016 2015 2014 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $186,752 $185,107 $183,242 School Board Exemption Value $25,000 Va) $25,000 Taxable Value $411,70 • $•210,107 •• •• $20$ 242 .. • • City•••••• • •. Exemption Value $60,940 • $50,1300 :$60,640 • Taxable Value $1$g,? • $385,107• • Y• $1$3242 •••• • • Regional'••••• •••• • Exemption Value • $504001. ;TOM • • (50••,00•0 Taxable Value $18$7$:f : $185,107 V.93.42 •• • •••... Sales Information. • • • ••• • • •• • • Previous Sale Price OR Book -Page Quairfication Description 12/01/1992 $230,000 15762-2519 Sales which are qualified 10/01/1989 $170,000 14282-3019 Sales which are qualified 08/01/1973 $20,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: SECTION 1524 HIGH -VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of this chapter govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics-worlunanship. Reserved. Renailing wood decks. When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High -Velocity Hurricane Zones) of this code. (The roof deck is usually concealed prior to removing the existing roof RIGL-Common roofs. Reserved.' Ave—Exposed ceilings. Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, rooting nail penetrations of the underside of the decking may not be acceptable, The owner provides the option of maintaining this appearance. Ponding water. Reserved. • • )" Overflow scuppers (wall outlets). It is required that rainwater flagt ap tlia.t.t4e wof is not • overloaded from a buildup of water. Perirneterledge walls or other tg4Ceictensiens' may bld�'ll' •" this discharge if overflow scuppers (wall outlets) are not provided. Itaxailhe riecessa?y to insiaall.••y overflow scuppers in accordance with the requirements of Chapter•d5• d 16 Atieih.and :'�••.• Florida Building Code, Plumbing. • • • • • • A44-, Ventilation. Reserved. O wn erAgent's Signature ature g !� (2—(4 `Z0/4 Date . . • • • • ...... `�. • ••• Contractor's Signature•