RF-16-3050Project Address Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138-0000 Phone: (305)795-2204 Permit NO. RF -11-15-3050 p • Permit Type: Roof ' Work Classification: Tile Permit Status: APPROVED Issue Date: 1111512016 Expiration: 05/14/2017 Parcel Number Applicant 195 NW 91 Street Miami Shores, FL 33138- 1131010000190 Block: Lot: DAVID PIRIANO Owner Information Address Phone Cell DAVID PIRIANO 195 NW 91 Street MIAMI SHORES FL 33127- (774)212-5876 195 NW 91 Street MIAMI SHORES FL 33127- Contractor(s) TOP SEAL SERVICES CORP Phone (305)754-7844 Cell Phone Valuation: Total Sq Feet: $ 21,000.00 3308 Type of Work: Re Roof Additional Info: Classification: Residential Scanning: 3 Fees Due Bond Type - Owners Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $12.60 $4.88 $4.88 $4.20 $325.00 $9.00 $16.80 $877.36 Pay Date Invoice # 11/15/2016 11/15/2016 Bond #: 3248 Pay Type RF -11-16-61988 Check #: 246 Check #: 5222 Amt Paid Amt Due $ 500.00 $ 377.36 $ 377.36 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHA ICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. IDAVIT: oning. co fy that all e, I ing information is accurate and that all work will be done in compliance with all applicable laws regulating the above-named contractor to do the work stated. ed Signature: Owner Th Ap. ica Building Department pY Contractor / Agent November 15, 2016 Date November 15, 2016 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-270807 Permit Number: RF -11-16-3050 Scheduled Inspection Date: December 27, 2016 Inspector: Riveron, Alexis Owner: PIRIANO, DAVID Job Address: 195 NW 91 Street Miami Shores, FL 33138 - Project: <NONE> Contractor: TOP SEAL SERVICES CORP Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number (774)212-5876 Parcel Number 1131010000190 Phone: (305)754-7844 Building Department Comments, RE -ROOF TILE TO TILE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. December 27, 2016 For Inspections please call: (305)762-4949 Page 8 of 28 FLORIDA'? \ TEC PROVIDING SOLUTIONS TO THE \ ROOFING INDUSTRY Lab Report No. 126764 C.A. # 30448 Lab Certificate # 13-0507.02 Tes CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO-DADE COUNTY PROTOCOL TAS -106 FROPERTYA.DDRESS: 195 NW 91st St., Miami OWNER: David Piriano CONTRACTOR: Murphy Roofs TILE TYPE Fid .41TACI-IMEN91• Polyf03m PERMIT No: RF -11-16-3050 ROOFING SQUARES: 34 ROOF PITCH: 4:12 INSPECIM INITIALS: AS & DW TEST MM.': 12/1912016 Required Testi nct Force: 35 lbs No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 14 Passed 441-4$ Passed 10-19 Passed 20-29 Passed 30-39 Passed • , i TIIIS ROOF HAS: PASSED ID FAILED .a THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI-DADE COUNTY TAS 106. 10735 SW 216th St. Unit 416 M Iarni-FL 33170 83' 2 48, 5 z r8 47 , M 10 ; 4 45 11 4»' 12 13 1-' 4`1 14 28 20 Er- -- ---v 18 L 19 Page I of 1 www.FioridaTEC.net 53' 123 - • • 31 25 • Tel: 305-2564455( Fax: 3O5-256-683 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-270804 (Flk ONO) Permit Number: RF -11-16-3050 Scheduled Inspection Date: November 18, 2016 Inspector: Diaz, Guillermo Owner: PIRIANO, DAVID Job Address: 195 NW 91 Street Miami Shores, FL 33138 - Project: <NONE> Contractor: TOP SEAL SERVICES CORP Permit Type: Roof Inspection Type: Tin Cap Work Classification: Tile Phone Number (774)212-5876 Parcel Number 1131010000190 Phone: (305)754-7844 Building Department Comments RE -ROOF TILE TO TILE Infractio Passed Comments INSPECTOR COMMENTS TIN CAP SPACEING False False Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Inspector Comments November 18, 2016 For Inspections please call: (305)762-4949 Page 21 of 34 AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE—BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami -Dade County Building Official 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name Property Address Roofing Permit Number Dear Building Official: certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water barrier has been provided as regiired by the "Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Structures" adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. I )92 A )4,7c? DA:kik cr 9 - N.v q I 14-' P4 If fc, 30SO ' /6) WdiL c-4.1-1) cwe-P) Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this day of (SEAL) Personally known or Produced Identification 20 E ;; :^.� • ANTOJ0 :ALO i ' 1 F*:6,n Eh Pt l\ Feortt, C2 .: 2d17? fi•. J - MY COM lit -': .1(4!.......121:35401115' cnda totary3ut'rg-m = r BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 Master Permit No. Sub Permit No. RECEIVED NOV 0 8 2016 4/(0k- FBC 20 I y 6 -X56 ROOFING ❑ REVISION ❑ EXTENSION El RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP JOB ADDRESS: i c — Ai CONTRACTOR DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): .`Q i C Y L 1 `\ A �l� Phone#: .77C1 P 1 'z_ -7,2Z, Address: i cl(� U`' '\.J t City: Y \ L_Y1/\ S � r k. -4\Q State: 1 4 6 Zip: Tenant/Lessee Name: Phone#: Email: NUI S JZT-oO-(S T J-�.) CONTRACTOR: Company Name: i\ SQ\ L;Cp ne#: c3e=4.—'0-i " Address: c "1 9 iv v3 57 -- City: ric"\_ I State: t` ( Zip: .�3(i/ a Qualifier Name: 1 I � N 1 (V-74 Phone#:-7O�T9 L. -rD..30 State Certification or Registration #: !ECC tCC ! 33°I 9 9 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: -- -) D g Value of Work for this Permit: $ Type of Work: ❑ Addition ❑ Alteration Description of Work: q251__�A—�- G Square/Linear Footage of Work: ❑ New 4 ❑ Repair/Replace ❑ Demolition Specify color of color thru tile: Submittal Fee $ G� Scanning Fee $ l Technology Fee $ C((:) ' ,90 Structural Reviews $ (Revised02/24/2014) Permit F Radon Fee $ ,S 25 - c CCF's 12 'C • DBPR$ - Training/Education Fee $ 2.0 CO/CC $ Notary $ Double Fee $ Bond $' TOTAL FEE NOW DUE $ 3.9-9 • �b Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City t'" ` State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien 1. - • . hure w .e delivered to the person me t must . e posted at the job site nce of ch posted notice, the whose property is subject to attachment. Also, a certified copy of the recorded notice of for the first inspection which occurs seven (7) days after the building permit is issue z inspection will not be approved and a reinspection fee will be charged. Signature Signature mmen . In the OWNER or AGENT The foregoing instrument was acknowledged before me this The foregoing i r ent w _ , m • edged before me this 10 day of DG\C`Xi-- , 20 (C' , by 3 day of c c_. , 20 f , by , who is personally known to me or who has produced 'wp as me or who has produced as , who is personally known -to identification and who did take an oath. NOTARY PUBLIC: identification and who did take an oath. NOTARY PUBLIC: Sign: ✓ Sign: Print: CoecA `u( � I••o Print: m CARO Seal: Geoffrey TOT es Potency Seal: t; • Notary Public MY COMMISSION # EE879367 State of Florida �', EXPIRE$ February 28.::017 (a07j998-0t6! FwrMallotarys vh APPROVED rn (', �pmmission No. FjP 9 1 (Revised02/24/2014) Plans Examiner Zoning Structural Review Clerk toggle Earth meters 100 50 OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami -Dade County Building & Neighborhood Compliance Department 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name d i ld /l e1 A /�1) Property Address (q5 --n/ L/ `7 / ,q /Air / S7/D0'S Roofing Permit Number Dear Building Offici I (P• certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. 11 The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). Signature of Property Owner V<6 "tilNO Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this 9 day of OC\ -c 1 , 20 ( C 0) (SEAL) Geoffrey Torres Polanco Notary Public State of Florida Personally known MyCommission Expires 02/11/2020 Cor Produced Identification Commission No. FF 959884 When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. Property, Search Application - Miami -Dade County Page 1 of 1 OFFICE Of THE PROPERTV APPRIUSER Summary Report Property Information Folio: 11-3101-000-0190 Property Address: 195NW91ST Miami Shores, FL 33150-2256 Owner DAVID PIRIANO Mailing Address 2101 LUCAYA BEND #J1 POMPANO BEACH, FL 33066 Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/3/0 Floors 1 Living Units 1 Actual Area 3,212 Sq.Ft Living Area 2,678 Sq.Ft Adjusted Area 2,715 Sq.Ft Lot Size 13,200 Sq.Ft Year Built 1959 Assessment Information Year 2016 2015 2014 Land Value $290,690 $214,460 $177,870 Building Value $141,723 $141,723 $138,057 XF Value $4,449 $3,263 $3,282 Market Value $436,862 $359,446 $319,209 Assessed Value $346,685 $315,169 $286,518 Benefits Information Benefit Type 2016 2015 2014 Non -Homestead Cap Assessment Reduction $90,177 $44,277 $32,691 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1 53 41 .29 AC M/L W135FT OF S1/2 OF SW1/4 OF NW1/4 OF SE1/4 LESS W35FT & S35FT FOR ST & LESS N169.25FT THEREOF LOT SIZE 100.000 X 132 Generated On 11/8/2016 Taxable Value Information Previous 2016. 2015, 2014 County Exemption Value $0 $0 $0 Taxable Value $346,685 $315,169 $286,518 School Board Exemption Value $0 $0 $0 Taxable Value $436,862 $359,446 $319,209 City Exemption Value $0 $0 $0 Taxable Value $346,685 $315,169 $286,518 Regional Exemption Value $0 $0 $0 Taxable Value $346,685 $315,169, $286,518 Sales Information Previous PriceSale OR Book- Page Qualification Description 05/26/2009 $280,000 26887-Qual 3946 by exam of deed 09/01/1991 $0 00000- 00000 Sales which are disqualified as a result of examination of the deed 08/01/1979 $76,500 10493- 1147 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: http://www.miamidade.gov/propertysearch/ 11/8/2016 RECEIVED fix n.10* 1 HIGH -VELOCITY HURRICANE ZOP Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Penmit No. Process No. F fib– SOC -1 Contractor's Name Job Address 05----/ut.,L3 9 ❑ Low Slope ❑ Asphaltic Shingles 0 New Roof ROOF CATEGORY 0 Mechanically Fastened Tile 0 Metal Panel/Shingles 0 Prescriptive BUR -RAS 150 ROOF TYPE ortar/Adhesh►e Set Tile Wood Shingles/Shakes 0 Recovering 0 Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof rea (SF) Steep Sloped Roof Area (SF) Total (SF) -2 3x) ) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, cleftly: • identify dimensions of elevated pressure zones and location of parapets. • • J n Q H a .0 J :1 ..6 w. wi.. w .T .0 U Y a z Z U ••O •, (. - Q J1. r c� ▪ 'n ••,.• • •••• • • • 4..•.,.•; • • • • •: • •.. • • ••.• •.,• •• • i • •. • • • • • •• • •. • : ..,•L•. :z • . • •• • ;• • •• •••.:•••• • • ;� • b • Vi • ; Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: .E/1/7'6Wq Product Approval Number: /. '• Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: P2: 51 /1:09'L 2/ 30 P2: c 3: Maximum Design Pressure Product Approval Specific System: 0/ Method of Tile Attachment: _ G i miff/ % Roof Slope: :12 Steep Sloped System Description Deck Type; eie7 / 7f Type Underlayment: j e214 /7r/Cee= Insulation: Ridge Ventilation? // 6. /v/d Fire Barrier: • • • . • r. • . Fastener Type & Spacing:' • s-.-. �.. . Adhesive Type: Mean Roof Height: • . • Type Cap Sheet: Sw6FTZe7447.4X . . • Roof Covering: 4416 Type & Size Drips Edge: • 5.41 •••• • • .•.. Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mt. If the Mrvalues are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. / Method 1 "Moment Based Tile Calculations Per RAS 127" r' (P,: x x,�S9-rKW779,...p43.67 Product Approval (P2: XX. 7_/Mg:-'%7 �� pp 1pD7r �'" ; 9�Mra/ ?Z.:CPI Product ApprovalM,,��•i (P3: x1,Z$. x'14) -M : 77 r.jev Product Approval M,".f� / .3 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mean Roof Height - . Roof Slope, - Mf Required Moment Resistance* 15' 20' 25' 2:12 3:12 4:12 34.4 36.5 38.2 32.2 34.4 36.0 5:12 30.4 28.4 32.2 33.8 30' 40' 39.7 42.2 37.4 35.1 39.8 37.3 30.1 6:12 26.4 28.0 7:12 24.4 25.9 31.6 29.4 27.1 32.8 34.9 30.5 32.4 28.2 30.0 *Must be used in conjunction wifih a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the F, values, for each area of tl-s roof, then the tile attachment method is acceptable. • • Method 3 "Uplift •Based Tile Calculations Per RAS 127" • • • • • • (P,:x1: xw:= )-W:xcos 0: - =F,_ (P2: .._ x 1: _---- Product Apprp f. x w:= ) - W: x cos 0: - = Ftz Product ApptColal ” (P3: x 1: x w:= ) - W: x cos 0: _ Fr, Product Apprn11*; •••••. •••• •••• • • • • • Description Design Pressure Mean Roof Height Roof Slope Aerodynamic Multiplier Restoring Moment due to Gravity Attachment Resistance Required Moment'Resistance Minimum Attachment Resistance Required Uplift Resistance Average Tile Weight The Dimensions Wh Symbol PI or P2 or P3 H 8 M, .. F, W 1= len0 w . widih_ AH calculations must be submitted to the Building 0 re to Obtain Information Where to find • .• • •• • • • • RAS 127 Table 1 or by an engineering analysis prepared by P% based on ASCE 7i Job Site • • • Job Site • Product Approval Product Approval Product Approval Calculated Product Approval Calculated Product Approval Product Approval fficial at the lime of permit application. • • • • • • • • •••• • • •• • • .•.••• • • •• • • • • • • • •• • • • • "Delivering Excellence Every Day" :t --- iMIAMI-DADE COUNTY {---- REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner s nthe designated required r dsroo ingindermitthat the , and to explain to the owner the content of this form. The owner's initials has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane the roofing system meets the wind resistance and water intrusion Zone) are for the purpose of providing that performance standards. Aesthetics (appearance) are not a consideration with respect to a ening ode m worans h be addressed Aesthetic issues such as color or architectural appearance, that are notp as part of the agreement between the owner and the contractor. j 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane roof system).Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing theexisting 3. Common roofs: Common roofs are those which have no visible delineation between me ghb and/or units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor owner should notify the occupants of adjacent units of roofing work to be performed. .,.__ Exposed, open beam ceilings are where the underside of the roof decking can be 1r�, 4. i• 3tpU�1dU l:Gttill�J. open viewed from below. The owner may wish to maintain the architectural ownerce; therefore, the optioning nail penetrations of the underside of the decking may not be acceptable. provides maintaining this appearance, 5. Ponding water: The current roof system and/or deck of the building ni4yn3t drain w01 and'rh tt: • cause to pond (accumulate) in low-lying areas of the roof. Ponding can be atrir licatior of gt uctutat.:. distress and may require the review of a professional structural engineer. Ponding nim horten tlf . life .• • expectancy and performance of the new roofing system. Ponding conditions may hait.i:e eviddA:t til thL originE roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow offs that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensionsom' scuptp�i'sr in a1? ti me overflow scuppers (wall outlets) are not provided. It may be necessary to install with. th- requirements of: Chapter 15 and 16 herein and the Florida Building Code, Picentbinr • : tar�r� 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing arrount of attic ventilation shall not be reduced. Owner's/Agent's Signature: Contractor's Signature: Property Address: tuber: MIAMI. COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) IIIAiVII-DADE COUNTY PRODUCT CONTROL SECTION T1805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade,eov/economy Entegra Roof Tile, LLC 1289 NE 9'h Ave Okeechobee, FL 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Pro.duct Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality. assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or loge, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed err: tfiare has been• o change • • in the applicable building code negatively affecting the performance of this product. • • TERMINATION of this NOA will occur after the expiration date or if there has been.e.irarrision o.m4eanle in Elie . . materials, use, and/or manufacture of the product or process. Misuse of this NOA as an eiriorsetnent vi;atty product,: • • • for sales, advertising or any other purposes shall automatically terminate this NOA. Fai1ufeVeQmply yvtt41,2tr�y sectit • • of this NOA shall be cause for termination and removal of NOA. • • • • • • • . .• . ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, blcrida, and'ol4ov'.d by the • expiration date may be displayed in advertising literature, If any portion of the NOA is disptiayejl, then gill be dcgte• • •; in its entirety. . . . .. • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufact rer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #14-1120.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMI•DADE COUNTY APPROVED NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 . Page 1 of 7 ROOFING ASSEMBLY APPROVAL` Category: Sub -Category: Material: Roofing r,S, Roofing Tiles Concrete 1. PRODUCT DESCRIPTION Manufactured by Applicant Plantation Tile Trim Pieces Dimensions Length: 16'/2" Width: 13" L = varies W = varies Varying thickness 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL Test Specifications TAS 112 TAS 112 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier American Test Lab of South RT0624.05-14 Florida Redland Technologies 7161-03 Appendix III The Center for Applied 94-060B Engineering, Inc. 94-084 Redland Technologies 7161-03 Appendix II Redland Technologies Letter Dated Aug. 1, 1994 Redland Technologies P0631-01 Redland Technologies P0402 The Center for Applied Project No. 307025 Engineering, Inc. Test #MDC -76 Walker Engineering, Inc. Calculations Walker Engineering, Inc. Calculations MAMt•DADE COUNTY APPROVED lr Product Description Flat concrete roof tile for direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report TAS 112 Static Uplift Testing PA 102 & PA 102(A) • Static Uplift TeStPg PA 101 (Adhesiv443) (Mortar Set} Wind Tunnel TesNi»g • PA 108 (Nail -Ort), • • • Wind Tunnel Tang •; PA 108 (Nail -011) • • Wind Tunnel Testin+ PA 108 (Mortar:§e':) Withdrawal ResistanceWting of screw vs. smooth shank nails Wind Driven Rair PA 100 Aerodynamic Multip:er 25-7183 25-7094 25-7496 Date 07/03/14 Dec. 1991 • • Malch, 1994 • ZM 1994 ••• eci 1991• •••• .•Mg,.1994 •• • fuly 1994• • • &pt. 1993, • • • ••• • Oct. 1994 •. • • • • • • • • March 1999 April 1999 March 1995 February 1996 April 1996 NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 2of7 • 2.2 SUBMITTED EVIDENCE: ,.r Test Agency Test Identifier Test Name/Report. Date l Walker Engineering, Inc. Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Farabaugh Engineering and T295-11 TAS-108 10/05/11 Testing Inc. Farabaugh Engineering and T306-11 TAS-108 10/04/11 Testing Inc. Farabaugh Engineering and T279-11 TAS-108 09/23/11 Testing Inc. 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. • • 3.7 All products listed herein shall have a quality assurance audit in accordance wwtA:the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. • • • M1AM[•DADE COUNTY APPROVED • •• • • • • • •••• .••• . • ••••• •..• .. . . . . . . ..• .. ..• . ...... • . . • • • • .• • • • • • • • ••• • •••• • • • •• • NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 3of7 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4,2 Data For Attachment Calculations Tile Profile Plantation Tile Table 1: Average Weight (W) and Dimensions (1 x w ) Weight -W (lbf) Length-1(ft) Width -w (ft) 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Plantation Tile Tile Profile (ft3) Batten Application X (ft3) Direct Deck Application 0.267 0.289 Tile Profile 2": 12" Battens Table 3: Restoring Moments due to Gravity - Mf (ft-Ibf) Direct Deck Plantation 7.22 7.91 Tile 3": 12" 4": 12" Battens Direct Deck Battens Direct Deck 5":12" 6":12" Battens Direct Deck Battens 6.85 7.79 6.75 7.67 6.61 7.52 6.44 Greater than 7": 12" Direct Battens Deck 7.32 6.26 Direct Deck 7.04 MtAMt.DADE COUNTY APPROVED • .• . • • • ..• • • . • . • .... .... .. . • . • . . ......• • • .. . • • .. • . . •1 • •..• . • • • .• . . • • . • • • • . .'. .. • NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 4 of 7 • J.,. -r. muaunrnent Kesrstance expressed as a Moment - Mr (ft-lbf) For Nall -On Systems Table 5: Attachment Resistance Expressed as a Moment Mr4(fte(?f ••• For Two Patty Adhesive Set Systems •• • Tile Profile Tile Profile Fastener Type Direct Deck (Min 15132" plywood) Direct Deck (Min. 19/32" plywood) • • • • • 31.3' • • •• _ 2 See manufactures component approval for installation requirements. •• ' • Battens Plantation Tile . 2-10d Ring Shank Nails 30.9 38.1 -• 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24,3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19,0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 • • -: 48.3 • ... 1 Installation with a 4" tile headlap and fasteners are located a minimum of 2%A" from the head of the •• • •,.. • Table 5: Attachment Resistance Expressed as a Moment Mr4(fte(?f ••• For Two Patty Adhesive Set Systems •• • Tile Profile Tile Application •••• •••• Mi trium A teofxnent •• ••;••liesistpm •• Plantation Tile Adhesive • • • • • 31.3' • • •• _ 2 See manufactures component approval for installation requirements. •• ' • • • •. 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. • • • • 3M- 2 -Component Foam Roof Tile Adhesive AH -160. Average weight per patty 8 grams. • •• •' •• •••• • Table 6: Attachment Resistance Expressed as a Moment - Mf (f,-ibf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance 118.94 Plantation Tile 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 40.45 4 Large paddy placement of 45 grams of 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 5 Medium paddy placement of 24 grams of 3M" 2 -Component Foam Roof Tile Adhesive AH -160. M1AMIOADE COUNTY APPROVED NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 5of7 •• • • • 0000 • •.• • • *00 •00 • • • • • •00• Table 7: Attachment Resistance Expressed as a Moment - Mr(ft-lbf) • for Mortar Set Systems Tile Profile Tile Application See specific mortar manufacturer's Notice of Acceptance. Attachment Resistance 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". OR PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY APPROVED • • • . .. . . • . . • .... .... • . • . . .... .... .. . • . . . • ..• .. ..• • . . . . •. . • . •• . • •. • . ..• .... . . . .. • NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 6 of PROFILE DRAWING PLANTATION FLAT CONCRETE TILE M1AMMADE COUNTY APPROVED END OF THIS ACCEPTANCE • • • •• •. • • • • • • • • •••• •••• • • • ••• •••• • • ..•..•••• • • • • • • •••• •• • • • • •• • • •• • • • • • • • •• •• • •.•• • • • •. • • • NOA No.: 15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/05/15 Page 7 of 7 MIAM DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.2ov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply v:[th, ay section of this NOA shall be cause for termination and removal of NOA. • ..• • . . ADVERTISEMENT: The NOA number preceded by the words Miami -Dade Cough,:1;1orida, anti followoed by the expiration date may be displayed in advertising literature. If any portion of the.NOA is disi94aned, then it shall be done in its entirety. y •••• •••• INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer o fits distriT tit rs and shall be available for inspection at the job site at the request of the Building Official. : •• ••• • • This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8. • ., • •• •: The submitted documentation was reviewed by Gaspar J Rodriguez. • .•.• • .• • • • • .• . • . NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 1 of 8 • ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick IR -Xe Manufacturing Location #1 & #2 Polystick Dual Pro Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick TU Max Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 Dimensions 65' x 3'3-3/8" Or 65'x3' 60 mils thick 61' x 3'3-3/8" 60 mils thick 61' x 3'3-3/8" 60 mils thick 65'8" x 3'3-3/8" 60 mils thick 32'10" x 3'3-3/8" 130 mils thick 65' x 3'3-3/8" 80 mils thick 65'8" x 3'33/8" 60 mils thick 65'8" x 3'33/8" 60 mils thick 32'10" x 3'3-%" Test Specification ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 TAS 103 TAS 103 and ASTM D 6164 Product Description A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. A rubberized asphalt self -adhering, glass-fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self -adhering, glass-fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self -adhering, polyester reinforced waterproofing membrane. Designed as a a roof tile underlayment. A rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self -adhering, glass-fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with poljolefnic film on the upper surface for use §s n uli derlayment for metal' • • • roofing, roof tile, slate tiles antl•shifigle uCderjUment. • • A homogeneous, rubberized ast.1 14 waterproofing • membrane, glass fiber reinfoVed'Njth pobytyleftic film on the upper surface for use as' an'inderlay? r?t for m&tai • •. roofing, roof tile, slate tiles aric�solii�gle uMaealayment. ..... . Polyester reinforced, SBS mOdl'a'tjbitumen thembrane with a sanded back face and t. granule top:stu11w. Fof use in roof tile underlaymentsy� 4ems. • • • . .• •••• • • • NOA No.: 15-0410.04. Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL Test Agency Trinity 1 ERD PRI Asphalt Technologies Momentum Technologies, Inc. EVIDENCE SUBMITTED Test Identifier P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 TAS 103/ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G155 TAS 110/ASTM D4798 & D1970 ASTM D 1623 ' ASTM D6164 TAS 103, TAS 110 & ASTM D1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 & TAS 110 ASTM D1970 & TAS 110 TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & 0155 Date 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 08/07/12 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 06/27/16 06/27/16 09/29/06 12/10/07 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Coi trgl�Approved" or the Miami -Dade County Product Control Seal as shown below. • . •'• • •• • • • MIAMI•DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. • • • •••• ••.• • . • • •••. ...• . .• • • • • • •• •• •• • • •. . • • • •• • • • • • • •••.•• • •• • • 2. Any other documents required by the Building Official or applicable building code in ordar.t'o koperly.evaluate Meinstallation of this materials. • • • IMILAIltrzfftiOUNTY •• • NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Deck Description: System Type E(1): Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(2): Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(3): Anchor/Base Sheet: Fastening: Ply Sheet: Membrane: Surfacing: Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type. II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. See General Limitations Below. Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type I1 or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Elastoflex S6 G, hot asphalt applied See General Limitations Below. Wood, non -insulated Min. 19/32" plywood or wood plank Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. One or more plies of ASTM D 226 Type 1I or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Polystick TU Plus, self -adhered. See General Limitations Below. .. • • • ..• • • • • .... .... • . .... .... .• • . • . . . . .. ..• • . •. • • • • • • • • . ... .... • . • • • • • . . • • • • • . NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 4 of 8 • INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-'/2" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the mem6rane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR -Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surfacLia%deck shall be free of irregularities. • •••• •• • • 5. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, PolystscJ.TU P,Mitick TLJ • Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre•c+kisting roof membrane • as a recover system. •••• ••••• • • • • • 6. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Po1ys,�_ TU P, PAlyStick TT,T•:••• Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a tempora?to3f for rbolgtsTan t114 .... amount of days listed in the table below after application. Polyglass reserves the rig):bbr vise or alter product •• exposure times; not to exceed the preceeding maximum time limitations. •••••• Exposure Limitations (Days) • •• masa •4101MTS IR -Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro• TU M?c.. •1VCTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A CIIIII=1,111A111,CLADE COUNTY NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 5 of 8 • •