Loading...
REV-16-2561Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION El BUILDING ❑ ELECTRIC ❑ ROOFING 0PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: C\2 Z- (o -k; &Je City: Miami Shores County: Folio/Parcel#:'i- 310\- 033 - Occupancy Type: Load: Construction Type: RECEr' 7 7_ L, SEP 1 &016 FBC 201Lk Master Permit No.W S 13 tLI Sub Permit No.RE v (CO- 2 ` o ❑ REVISION ❑ EXTENSION RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS Miami Dade zip: 33150 Is the Building Historically Designated: Yes NO Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): MORD 0\6. SO Phone#: Address: °12)26 3 IAiyt; b�C� City: t-`►Nrl; ji�rt.E S Tenant/Lessee Name: N/A Email: N/A State: VA Zip: 331517 Phone#: N/A CONTRACTOR: Company Name: FLORIDA HOME IMPROVEMENT Address: 4070 SW 30 AVE Phone#: 954-7924415 City: HOLLYWOOD State: FL zip: 33312 Qualifier Name: WAYNE T. BURNETT State Certification or Registration #: CGC061890 DESIGNER: Architect/Engineer: N/A Phone#: Address: N/A City: N/A Value of Work for this Permit: $ '� Square/Linear Footage of Work: Phone#: Certificate of Competency #: N/A State: N/A Zip: N/A Type of Work: ❑ Addition n Alteration n New`, ❑■ Repair/Replace ❑ Demolition • - Description of Work: — — lt; Specify color of color thru tile: Submittal Fee $ Permit Fee $sS' ° CCF $ CO/CC $ Scanning Fee $ 9, Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ T �f • Gj (Revised02/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address N/A City N/A State N/A Zip N/A Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address N/A City N/A State N/A Zip N/A Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this !i ' _n day of .P , 20I L , by OSS 0 who is personalln to me or who has prod identification and NOTARY PUBLI d as did take an oath. Sign: Print: Seal: APPROVED BY (Revised02/24/2014) it`al(AJ) Signature CONTRACTOR The foregoing instrument was acknowledged before me this qt9 day of J6 , 20 1 ( , by W IE T• 2aJ v ads personally(now to me or who has prod identification an NOTARY PUBLI 11 nve Sign: Print: Seal: Plans Examiner o,• id take an oath. as NZA[pF�p/��r • .;)0 2017A�9�: Structural Review ,tom s��z AFF o3 pps is OT • Notary W ;J�"` C e'� � PPUBLI i q. °° t'��,� Zoning Clerk NOTE 1. EXISTING OPENING SIZE DOES NOT CHANGE. 2. ALUMINUM TO BE 6063—T6 MIN. 3. WATERPROOFING, BY OTHERS. 4. NOTIFY THIS ENGINEER OF ANY DISCREPANCIES. PROVIDE (2) ADDITIONAL TAPCONS WITHIN 1" OF VERTICAL MULLION INTERSECTION (1 EACH SIDE OF MUWON) EXISTING 4X WOOD HEADER BEAM NEW 1 x3xd" 6063—T6 ALUMINUM REC. TUBE 12'-0" INSPECTOR NOTE STRUCTURE WAS DESIGNED BASED ON THE 2014 FLORIDA BUILDING CODE AND ASCE 7-10, 175 MPH (3 SEC), EXP. C. RISK CAT. 2. INSPECTOR NOTE REPAIRS ARE OF A LEVEL 1 ALTERATION IN ACCORDANCE WITH 403.1 OF THE EXISTING BUILDING CODE. CLIENT INFORMATION FLORIDA HOME IMPROVEMENTS 3044 SW 42nd STREET FORT LAUDERDALE, FL 33312 PROJECT INFORMATION OLASO RESIDENCE 9826 N. MIAMI AVE MIAMI SHORES, FL HEADER MULLION DETAIL SPECIALTY ENGINEERING CONSULTANTS, Inc 1599 SW 30th AVE SUITE 120 BOYNTON BEACH, FL 33426 DADE — BROWARD — PALM BEACH FL. CA. 1009217 561 — 752 — 5440 OFFICE 561 — 752 — 5542 FAX NEW 1 x3xr 6063—T6 ALUMINUM REC. TUBE 2X4 MUWON, BY OTHERS CO CO 1 1 1 1 1 1 1 111111 11 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1111111111111111 1 1 1 1 111111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1111 1 11 1111 1 1 1 I I 1 1 I I I 1 I I 1 I 1 1111111 I I 1 I Y I I X I 1 NEW Y"x7" ALUMINUM PLATE FASTENED TO EXISTING MASONRY WALL W/ Y"0 x 3 Y" ULTRACONS ® 6" 0.C. (1 Y4" MIN. EMBEDMENT, 2 h" MIN. EDGE DISTANCE) PARTIAL ELEVATION SCALE: 3/8" = 1'-0" NEW IMPACT WINDOWS, BY OTHERS. NEW 1 x3xr 6063—T6 ALUMINUM REC. TUBE 2" 0 0 2" 1 x3xr ALUMINUM REC. TUBE EXISTING BRICK VENEER OVER 8" MASONRY WALL EXISTING CONCRETE FOUNDATION PFR Ii" #: 1t 5(o 1 Miami Shc!aB Village APPROVED BY DATE ZONING DEPT BLDG DEPT I (0 tAe SUBJECT iO CCMPUANCE WITH ALL FEDERAL STATE ANu CCUIYiY RULES AND REGULATIONS PLAN COMMENTS 07/07/16 FASTEN TO: *WOOD W/ (2) #14 x 3" WOOD SCREWS (1" EDGE DISTANCE, 2" MIN EMBEDMENT) *ALUMINUM W/ (2) #10x 1 Y4" TEK SCREWS *CONCRETE W/ (2) Y4"0 X 3 Y4" ULTRACONS ( 2 N2" EDGE DISTANCE, 1 Y4" MIN. EMBEDMENT 2" MIN. SPACING) • • • • • ••• . FASTEN CLIP TO MULLION W/ (2) #10 x 1" FH TEK SCREW:•• EACH SIDE. MULLION CLIP CONNECTIONS SCALE: 6" = 1'-0" •••• • • •••• • • •• •• • • • • • • • • • • •• . .•• • • • • • • • •• • • . •••. • • • • •• • • • • • • • 00000 • •• •• • • • • • •••• • • • •• • PROVIDE (2) ADDITIONAL TAPCONS WITHIN 1" OF VERTICAL MULLION INTERSECTION (1 EACH SIDE OF MUWON) EXISTING 4X WOOD HEADER BEAM NEW 1X3X1fi" 6063—T6 ALUMINUM REC. TUBE. FASTEN TO WOOD BEAM W/ #12 X 3" S.S. WOOD SCREWS ® 6" 0.C. (PLACE FASTENERS IN CENTER OF REC. TUBE) MULLION TO BEAM CONNECTION SCALE: 3" = 1'-0" NEW IMPACT • tet• ea • oo SEP 0 80t STAT ONAL sTql is .• • • • • • EXISTING CONCRETE BEAM, NO CHANGES. EXISTING WOOD TRUSSES 24" O.C., NO CHANGES. EXISTING WOOD HEADER, NO CHANGES. NEW IMPACT WINDOWS, BY OTHERS. NEW Y"x7" ALUMINUM PLATE FASTENED TO EXISTING MASONRY WALL W/ Y4"0 x 3 Y" ULTRACONS ® 6" O.C. (1 Y" MIN. EMBEDMENT, 2 )i" MIN. EDGE DISTANCE) IDEALLY A 36, 72", AND 36" LENGTHS TO BE USED. CENTER THE 72" MEMBER UNDER THE CENTER MULLION. EXISTING BRICK FINISH CLIENT INFORMATION FLORIDA HOME IMPROVEMENTS 3044 SW 42nd STREET FORT LAUDERDALE, FL 33312 PROJECT INFORMATION OLASO RESIDENCE 9826 N. MIAMI AVE MIAMI SHORES, FL HEADER MULLION DETAIL SPECIALTY ENGINEERING CONSULTANTS, Inc 1599 SW 30th AVE SUITE 120 BOYNT N BEACH, FL 33426 DADE — BROWARD — PALM BEACH FL CA, 1009217 561 — 752 — 5440 OFFICE 561 — 752 — 5542 FAX NEW 1 x3x11" 6063—T6 ALUMINUM REC. TUBE PROVIDE CLUSTER OF (2) Y"0 x 3 Y4" ULTRACONS ® 2" 0.C. AT END MULLION INTERSECTIONS PROVIDE CLUSTER OF (3) Y4"0 x 3 Y" (1 Y4" MIN. EMBEDMENT, 2 Ji" MIN. EDGE DISTANQ)RACONS 0 2" O.C. AT MIDDLE MUWON INTERSECTION (1 Y" MIN. EMBEDMENT, 2 MIN. EDGE DISTANCE) NOTES 1. EXISTING OPENING SIZE DOES NOT CHANGE. 2. ALUMINUM TO BE 6063—T6 MIN. 3. WATERPROOFING, BY OTHERS. 4. NOTIFY THIS ENGINEER OF ANY DISCREPANCIES. INSPECTOR NOTE STRUCTURE WAS DESIGNED BASED ON THE 2014 FLORIDA BUILDING CODE AND ASCE 7-10, 175 MPH (3 SEC), EXP. C. RISK CAT. 2. INSPECTOR NOTE REPAIRS ARE OF A LEVEL 1 ALTERATION IN ACCORDANCE WITH 403.1 OF THE EXISTING BUILDING CODE. NEW Y"x7" ALUMINUM PLATE FASTENED TO EXISTING MASONRY WALL W/ Y"0 x 3 Y" ULTRACONS ® 6" O.C. (1 Y4" MIN. EMBEDMENT, 2 i " MIN. EDGE DISTANCE) 2X4 MULLION, BY OTHERS EXISTING BRICK FINISH • PLAN COMMENTS 07/07/16 • • • • • •• • NEW 1 x3xr 3 s 6 ALUMINUM RGG..IIJBE v \ 9 EXISTING MASONRY/CONCRETE SILL WALL. EXISTING FOUNDATION. EXISTING WINDOW CONCRETE SILL/STEM WALL SECTION VIEW SCALE: 3/4" = r-0" 2" 2" ••.• • • •0•• • • •,•• • • 0000 • •• • • • • • ••. • •• • • • ••.•.• .' • • • • .00• • • • • • • • • ••• • S' 0•••• •. • • • EXISTING MASONRY/CONCRETE SILL WALL BELOW PLATE. • sib ,1ttiiii ALUMNUM PLATE INSTALLATION PLAN.���,,`�ttttt• 6171.4%F.e:-, No 56214 • SCALE: 3/4" = 1'-0" 0 /ON 0000 A1 -E0 2" OV' 2