Loading...
REV-16-2129BUILDIN PERMIT APPLICATION BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 05) 756-8972 ER: (305) 762-4949 ❑PLUMBING ❑ MECHANICAL `r' 'rc r JUL 2 8 2015 BY•_ - 41 -1 FBC 2OIt( Master Permit No. WS -2-16-479 ❑ ROOFING REVISION Sub Permit No. v 1' — 2,129 ❑ EXTENSION ❑RENEWAL El PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1255 NE 95 STREET City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel#:11-3206-014-4000 Occupancy Type: Load: Construction Type: Is the Building Historically Designated: Yes NO OWNER: Name (Fee Simple Titleholder): BLAINE WILLENBORG Address: 1255 NE 95 STREET Flood Zone: BFE: Phone#: FFE: City: MIAMI SHORES State: FL Tenant/Lessee Name: N/A Email: N/A Zip: 33138 Phone#: N/A CONTRACTOR: Company Name: THE COMPANIES OF R&S INC Address: 8715 SW 129 TERR Phone#: 305-256-6666 gar -MT -220r City: MIAMI Qualifier Name: ; 4 DOWNEY,,�A6AI State Certification or Registration #: CGC016750 State: FL Zip: 33176 Phone#: 305-256-6666 Certificate of Competency #: DESIGNER: Architect/Engineer: AL-FAROOQ CORP / JAVAD AHMAD Address: 9360 SUNSET DR #220 City: MIAMI Phone#: 305-264-8100 State: FL Zip: 333173 Value of Work for this Permit: Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New • Repair/Replace ❑ Demolition Description of Work: REMOVE AND REPLACE EXISTING WINDOWS AND DOORS BY CGI IMPACT WINDOWS & DOORS f v iic J ,71-0,946:A/7- 1'c 7At/G A Specify color of colo thru tile: Submittal Fee $ . Permit Fee $ �� • C. CCF $ CO/CC $ _,\ Scanning Fee $ 3 • \ Radon Fee $ DBPR $ Notary $ Training/Education Fee $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ l 9 -Cio Technology Fee $ Structural Reviews $ (Revised02/24/2014) Bonding Company's Name (if applicable) A// f Bonding Company's Address k • City State Zip Mortgage Lender's Name (if applicable) /4 4_' Mortgage Lender's Address NlA- City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. The foregoing instrument was acknowledged before me this 76 day of ` 3U / , 20 1 (� , by gks:D2 r,e ) % \` .'1'lb�Q , who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Rr`ELO CAR N apvr, y/_n'C" EXP1Rt, to 407)3)3998.0153 FlorNfaNdarY' com APPROVED BY (Revised02/24/2014) as l Signature A .4 The foregoing in ument was acknowledged before me this Z.--(-1dayof I ,20 ( ,by CONTRACTOR To -AA Y\17-1 _ o J11t7/, who is(personally know to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Plans Examiner twk y07)398-0153 Structural Review EDWIN MA RC • CAR tON MY COMMIS • N # DID 7R EXPIRES May 21, 20 FlorldallotaryService.com Zoning Clerk August 15, 2016 To: Miami Shores Village Building Department 10050 Northeast 2nd Avenue Miami Shores, Fl 33138 Reference: Willenborg residence 1255 Northeast 95th Street Miami Shores, FL 33138 The installer from R & S Windows has reviewed with the homeowner the outside appearance for final construction with the final permit revision for Miami Shores Village. We agreed with the installer there would be wood added with a metal cap on the exterior widows in question, all corners consistent in appearance. w�n�s Blaine Willenborg , Wj....ain Lori Willenborg ALwFAROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT August 10, 2016 AFC #: 16-0710 Mr. Jack Downey •••• • • R & S Windows ; W-8 SH -11110- 39x41 PSF +53.11-71.1 NOA: 15-0512.10 W-7 SH 19x40 PSF +53.1/-57.6 NOA: 15-0512.10 W-6 SH -----11110- 37x52 PSF +53.11-71.1 NOA: 15-0512.10 GARAGE DOORS TO REMAIN STORAGE BATH W-5 171 SH 37x52 PSF +53.1/-71.1 NOA: 15-0512.10 KITCHEN D-2 DD --11110- 47x80 PSF +53.1 -57.6 NOA: 14-1015.04 W-4 SH 19x40 PSF +53.11-57.6 NOA: 15-0512.10 W-3ab SH 28x79 PSF +53.11-71.1 NOA: 15-0413.03 BATH W-9 SH 39x41 PSF +53.11-71.1 NOA: 15-0512.10 W-10 SH 31x60 PSF +5 .1/-57.6 NOA: 1 FOYER 512.10 FIRST FLOOR Mullion attachment detail D-3 SD 37x86 PSF +53.1 -57.6 NOA: 14-1015.04 MULLION NOA: 15-0420.08 SIZE:2x4x87 W -11a 4X4STEEL W -12a COLUMN MULLION NOP: 15-0420.08 HR HR SIZE: 2x4xe7 111x54 111x54 U 404 STEEL XOX XOX Ilr COLUMN PSF +53.11-57.6 PSF +53.11-71.1 NOA: 15-0512.05 NOA: 15-0512.05 OFFICE MULLION NOA: 15-0420.08 SIZE: 182x880 LION NOA: 150420.08 SIZE: 2+4+87 W -11b HR 111x26 PDX PSF 1.53.11-57.6 NO, 15-0512.05 MULUON NOA: 15-0420.00 SIZE: 2140112 DINING ROOM W -12b, W -13b ---► HR 111+26 XOX PSF +53.5-57.6 NOA: 15-0512.05 404 STEEL COLUMN MULLION NOA: 15-0420.08 i SIZE: 2+4187 W -13a HR 111x54 XOX PSF +53.11-71.1 NOA: 15-0512.05 4X4 STEEL COLUMN WINDOW OPENING FRONT VIEW DETAIL CGC 016750 4x4 STEEL COLUMN 404 STEEL COLUMN MULLION NOA: 15-0420.08 SIZE: 2+4 464 STEEL COLUMN MULLION NOP: 15-0420.08 SIZE: 284 D-4 D-5 SD SD 37x86 33x92 PSF +53.1 PSF +53.1 -57.6 -57.6 NOA: 14-1015.04 NOA: 14-1103.08 MULLION NOA:15-0420.08 SIZE: 204+112 MULUON NOA: 15-0420. SIZE: 244687 W-2ab SH 28x79 PSF +53.11-71.1 NOA: 15-0413.03 ENTRY D-1 TO REMAIN w-1 SH 37x79 PSF +53.11-57.6 NOA: 15-0512.10 LIVING ROOM W-19 SH 37x79 PSF +53.1/-57.6 NOA: 15-0512.10 MULLION N06:154420.08 SIZE 284+60 FAMILY ROOM 2x4 Vertical mullions Are attached to the 4x4 steel column thru Selft drilling screws ss#14x21r W-14 HR 81x60 XOX PSF +53.11-71.1 NOA: 15-0512.05 MULLION NOP: 1+420.08 u2 SIZE: %x66 W-18 ••• ••• • SH • • 37x79 • •••• • ••• ••• • PSF +53.11-5'1:6 • • • NOA: 15-0512.10 16b L HR 69x60 oxxo PSF +53.11-57.6 NOA: 15-0512.05 • • • • • •• •W1? • • • • •• . . •• • • • 64 7 • • • • PSF +53.1/-57.6 NOA: 15-0512.10 ••• • ••• • •• • • • • • • • • • • •• • • . • • • • • • • • • • • • • • • ••• •• •• • • • • • • • • • • • • • • • •• •••• • 16a FC"_V.TA JUL 2 8 016 HR' 69x60 OxxO PSF +53.11-71.1 NOA: 15-0512.05. 15b REVISIOI • • ALL NEW WINDOW SHALL MEET EGRESS REQUIREMENT AS PER F.B.C. 2014 • • • • • • ALL NEW WINDOW & DOOR SHALL COMPLY WITH SAFE GUARDS REQUIREMENT AS PER F.B.C. 2014 Project: Since 1954 WJLLENBORG RESIDENCE 355 NE 95TH STREET MIAMI SHORES, FL 33138 COUNTY and CITY: Miami -Dade County MIAMI SHORES Drawn by: Jose Eduardo Perez Permitting Specialist LEGEND: All escape windows shall provide a Clear opening of not less than 5.7 SQFT. The width shall be not less than 20" and The height shall not be less than 24". The bottom of the opening shall not be More than 44" above finished floor Notes: Remove and Replace fisting windows/doors SD: Single Door DD: Double Door SGD: Sliding Glass Door • - FGD: Fiberglass Door • SH: Single Hung • HR: Horizontal Roller • CSMENT: Casement • FIXED: Fixed • PO: Project Out • ST: Store Front A 1 N.T.S. W-30 SH 37x53 PSF +53.11-71.1 NOA: 15-0512.10 EGRESS W-24 SH 37x39 PSF +53.11-57.6 NOA: 15-0512.10 W-26 CSMENT 37x53 PSF +53.11-57.6 NOA: 15-0512.19 EGRESS W-29 CSMENT 37x53 PSF +53.11-57.6 NOA: 15-0512.19 EGRESS B E D R 0 0 M BATH BEDROOM W-31 SH 37x53 PSF +53.11-57.6 NOA: 15-0512.10 EGRESS W-25 SH 37x53 PSF +53.1/-71.1 NOA: 15-0512.10 EGRESS W-33 SH 19x39 PSF +53.11-57.6 NOA: 15-0512.10 BATH • ALL NEW WINDOW REQUIREMENT AS • ALL NEW WINDOW COMPLY WITH SAF AS PER F.B.C. 2014 W-28 SH 37x39 PSF +53.11-57.6 NOA: 15-0512.10 W-23 SH 37x53 PSF +53.11-57.6 NOA: 15-0512.10 W-27 SH 37x53 PSF +53.11-71.1 NOA: 15-0512.10 EGRESS MASTER BEDROOM SHALL MEET EGRESS PER F.B.C. 2014 & DOOR SHALL E GUARDS REQUIREMENT W-32 SH 37x53 PSF +53.11-71.1 NOA: 15-0512.10 EGRESS W-34 SH 19x39 PSF +53.11-71.1 NOA: 15-0512.10 MASTER BATH .• •.. . • W21 Ski• 0 W-22 CSMENT 37x53 PSF +53.11-57.6 NOA: 15-0512.19 EGRESS W-20 SH 37x53 PSF +53.11-71.1 NOA: 15-0512.10 EGRESS • • .• • • 3 PSF +53.11-71.1 NOA: 15-0512.10 �GR�SS • .•• • . • •• . • • . • . • • •• . • • • •• . • . . .• • . • • • • • •• • ▪ . . •.. • .• • . .. .• • ••• • • • • ••• • • • • • • • • • • • ••• • • • • • • • •• •• • • • •• • ••• • • • ••• • SECOND FLOOR Project: WILLENBORG RESIDENCE 1255 NE 95TH STREET MIAMI SHORES, FL 33138 COUNTY and CITY: Miami -Dade County MIAMI SHORES Drawn by: Jose Eduardo Perez Permitting Specialist LEGEND: All escape windows shall provide a Clear opening of not less than 5.7 SQFT. The width shall be not less than 20" and The height shall not be less than 24". The bottom of the opening shall not be More than 44" above finished floor Notes: Remove and Replace existing windows/doors • SD: Single Door • DD: Double Door • SGD: Sliding Glass Door • FGD: Fiberglass Door • SH: Single Hung • HR: Horizontal Roller • CSMENT: Casement • FIXED: Fixed • PO: Project Out • ST: Store Front A 2 N.TS.