RF-16-1898Project Address
Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Pe
mit
Issue Date: 7/14/2016
Permit NO. RF -7-16-1898
Permit Type: Roof
Work Classification: Tile
Pennit Status: APPROVED
Expiration: 01/10/2017
Parcel Number
Applicant
652 NE 105 Street
Miami Shores, FL
1122310120140
Block: Lot:
KILUAN, INC
Owner Information
Address
Phone
Cell
KILUAN, INC
652 NE 105 Street
MIAMI SHORES FL 33138-
150 SE 2 Avenue
MIAMI FL 33131-
Contractor(s)
AFFORDABLE ROOFTEC, INC
Phone CeII Phone
(954)962-9670 (954)931-8458
Valuation:
$ 4,900.00
Total Sq Feet: 434
Type of Work: Re Roof
Additional Info: NEW ROOF- NEW ADDITION ONLY - SANTA
Classification: Residential
Scanning: 3
Fees Due
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee'- New Roof
Scanning`Fee
Technology Fee
Total: ^'
Amount
$3.00
$3.75
$3.75
$1.00
$250.00
$9.00
$4.00
$274.50
Pay Date Pay Type
Invoice # RF -7-16-60488
07/14/2016 Credit Card
07/08/2016 Credit Card
Amt Paid Amt Due
$ 224.50 $ 50.00
$ 50.00 $ 0.00
Available Inspections:
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining`ttiereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERSAFFIDAVIT: I certify- at all the foregoing inform ion -ie -accurate and that all work will be done in compliance with all applicable laws regulating
construction'and zoning. Fu more, I author' - • - - .ove-named contractor to do the work stated.
Authorize•, ignature: Owner / Applicant / Contractor / Agent
Build Department Copy
July 14, 2016
Date
July 14, 2016
1
f
1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
12_0 2318
Inspection Number: INSP-265851 Permit Number: RF -7-16-1898
Scheduled Inspection Date: December 13, 2016
Inspector: Naranjo, Ismael
Owner:
Job Address: 652 NE 105 Street
Miami Shores, FL
Project: <NONE>
Contractor: AFFORDABLE ROOFTEC, INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number
Parcel Number 1122310120140
Phone: (954)962-9670
Building Department Comments
NEW ROOF- NEW ADDITION ONLY - SANTA FE CLAY
TILES- TERRA COTA
Infractio Passed Comments
INSPECTOR COMMENTS
False
Passed
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP-262774. Foam may not be
exposed on the valley. Need to proved open valley and with mortar on the
sides.
",;r4
December 12, 2016
For Inspections please call: (305)762-4949
Page 6 of 33
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
BUILDING 0 ELECTRIC Q ROOFING
0PLUMBING 0 MECHANICAL ❑PUBLIC WORKS
JOB ADDRESS: 652 NE 105th Street
City:
BY:
JUL 08 211
FBC 201(4
Master Permit No.1\\- 9 " 15- 7-'191
Sub Permit No. 1Z 66 i S?&
• REVISION EXTENSION ❑ RENEWAL
O CHANGE OF 0 CANCELLATION SHOP
CONTRACTOR DRAWINGS
Miami Shores County:
Miami Dade Zip:
Folio/Parcel#: 11-2231-012-0140
Occupancy Type: SFR
Is the Building Historically Designated: Yes NO X
Load: Construction Type: Structural
Flood Zone:
BFE: FFE:
OWNER: Name (Fee Simple Titleholder): Kiluam Inc Phone#: 954-663-6743
Address: 652 NE 105 Street
City: Miami ShoresState: FL Zip: 33138
Tenant/Lessee Name:
Email:
Phone#:
CONTRACTOR: Company Name: Affordable Rooftec Inc
Address: 2117 SW 57th Avenue
Phone#: 954-962-9670
City: West Park State: FL Zip: 33023
Phone#: 954-931-8458
Qualifier Name: Miorika M Malinetescu
State Certification or Registration #: CCC 057535 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ 4900.00 Square/Linear Footage of Work: 434
Type of Work:
❑ Addition ❑ Alteration
■❑ New ❑ Repair/Replace
Description of work: New Roof - New Addition only - Santa Fe Clay Tiles - TerraCota
❑ Demolition
Specify color of color thru tile:
Submittal Fee $ 'L • 0° Permit Fee $ 0,5o •bc
Scanning Fee $ l .0�
Technology Fee $ 4•Q3
Structural Reviews $
Radon Fee $ J •1 S
(Revised02/24/2014)
Training/Education Fee $
CCF $ S • v `' CO/CC $
DBPR $ 3.75 Notary $ $—
• () Double Fee $ "-C-9"
Bond$ 'EZ W -S'" -2N, IU
TOTAL FEE NOW DUE $ PRL-1 •
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS; ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be app oved and a reinspection fee will be charged. l
Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
day of JOU\\(
Sign
/"."
The foreg• ng instrument was acknowledged before me this
0 RACTOR
, 20 tcp , by day ofv�3- 0\1 , 20 ( (0 , by
nn !C�1 I' t fI t(!I i 1
M k L J3 �.! VL 1 , who is personally known to
me or who pr ddc ;(Ul
identification 'di a an oath.
NOTARY PUBLIC:
Sign:
Seal:
as
**************
APPROVED BY
(Revised02/24/2014)
SIMONA LELUTIU
MY COMMISSION # FF 154759
EXPIRES: August 26, 2018
?' Bonded T u Notary Public Underwriters
**********
ho is personally known to
me or who has prod ced as
identification an o did take
NOTARY PU
AiiiillIO
Sign:`'�
•rint: 1111/...16
Seal:
SIMONA LELUTIU
MY COMMISSION # FF 154759
EXPIRES: August 26, 2018
r ; Bonded Thru Notary Public Underwriters
**********************************************************
Plans Examiner Zoning
Structural Review Clerk
HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION
FLORIDA BUILDING CODE 2014 5th Edition
High -Velocity Hurricane Zones Uniform Permit Application
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTION OF THE UNIFO
PERMIT APPLICATION FORM AND ATTACH THE REQ
DOCUMENTS AS NOTED BELOW:
Roof System
Required Sections Of The
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR -RAS 150
A,B,C,
4,5,6,7
Asphaltic Shingles
A,B,D
1,2,4,5,6,7
Concrete or Clay Tile
A,B,D
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles And Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7 — '`'
ATTACHMENTS REQUIRED:
BY.
CEIVED
JUL 0 8 2016
1.
Fire directory listing page
2.
From Product Approval:
Front Page
Specific System Description _
Specific System Limitations
General Limitations
.Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if Applicable RAS, 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
•• ••• • • • • • ••
•
• ••
• • • •
•
•• ••• •• • • • ••
• ••• •
•• • • •
• •
• •• • •
•• • ••
•
• •• • •
• •
•••
•
•
•
•
•••
7Efl SIT #: RFI&- (8cT
ArDPROVED
Miami Shcres Village
BY
• • •1 ▪ C�;ING DEPT
• • • • • •i.
• •
••• BLDG ')EPT
•• • •••••• •• ••
• •• • •
•
• • ••• • . •
•L: VIEANS•(RULES AND REGULATIONS
• • • • • • • • • •
-Dcvp
3JECT CCh1PLUINCE WITH ALL FIEDERAL
• • ••• • •
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Master Permit No. Process No.
Contractors Name Affordable Rooftec Inc (954) 962-9670
Job Address
ROOF CATEGORY
❑ Low Slope 0 Mechanically Fastened Tile IN Mortar/Adhesive Set Tiles
0 Asphaltic Shingles 0 Metal Panel/Shingles 0 Wood Shingles/Shakes
0 Prescriptive BUR -RAS 150
ROOF TYPE
New roof 0 Repair 0 Maintenance 0 Reroofing 0 Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) Total (SF) 434
NA
434
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels. clearly identify dimensions of elevated pressure zones and location of parapets.
• • • • • • • •
• • • .•• • • •
• • • • • • • • • •
• • • • • • • • • • • •
000 • • • ••• • •
e
C4
••
••• •
•
•
•
••
•
•
•
• •
• •
• • •
•
•
•
• •
• •
• •
• •
• •
D • •
• • •
•• •• •
•
•
•
4 4
•
• •
• ••
• ••• •
•
• •
• • 1 •
• • 1 •
• • 1 • •
•
•
•
•
•
• •
• •
• •
• •
1
1
,
• ►• •
•• 1 •
•
•
•
• •
••• •
•
8-
• • • • • • • •
• • • .•• • • •
• • • • • • • • • •
• • • • • • • • • • • •
000 • • • ••• • •
3x3 Eave 26 gauge Ga
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: Santafe Tile Corportation - Spanish 'S' Clay Roof Tile
Notice of Acceptance Number: 12-0210.01
Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations):
P1: P1: P1:
Roof Sbpe:
3 : 12
Deck Type:
Plywood
Type Underlayment:
Ridge Ventilation?
\ Insulation:
30# ASTM Felt Type 2
N/A
Fire Barrier:
N/A
\ Fastener Type & Spacing:
Mean Roof Height: 13
.
jt Adhesive Type:
1 1/4" Ringshank Nails wl 1 5/8° Tincaps
Field: 12" o/c, Lap: 6" o/c, Dripedge: 4' o/c
90# ASTM w/ asphalt
Type Cap Sheet:
N/A
'\. Roof Covering:
• . \..
. . .
•
.
•
.. ... .. .
SantaFe Spanish S Clay-TerraCote
.;\ Type & Size Drip
....: Edge:
I
• ... . . .
. • .• . .• . . . .
• . . • . • . . . •
• . . •. •. •.
. • . • • . . .
.....•
.
... .•••• .
•
. • . . . . . •
. . •. • •. •.
... •. . . • .
• ..• .. •
• . . •....
... . •••
... • .
Ivn
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values
are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 `Moment Based Tile Calculations Per RAS 127"
(P1:39.1 x 10.274 = 10.71 ) - Mg: 5.82 = M 4.89 Product Approval M 63.8
(P2:68.1 , 0.274= 18.66) - Mg: 5.82 = M2 12.84 Product Approval M, 63.8
(P3:100.7)0, 0.274= 27.59) - Mg: 5.82 = Ma 21.77 Product Approval M, 63.8
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (M) From Table Below 32.2 product Approval M, 63.8
M, required Moment Resistance'
Mean Roof Height
Roof Slope
15'
20•
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and
Appeals.
For Uplift based tile systems use Method 3. Compared the values for F with the values for Fr. If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 127"
(P1: x L = x w: _ ) - W: x cos 0 = F,, Product Approval F
(P2: x L = x w: _ ) - W: x cos 0 = Fn Product Approval F
(P3: x L = x w: = ) - W: x cos 0 = Fa Product Approval F
• • • •
• •• •• • • • •• ••
••• • • • •• ••• • •
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
• • • • • • Z. • • •
•
•
Product Approval
Restoring Moment due to Gravity
.• • . ..11 ' * * • *
' ••
Product Approval
Attachment Resistance
. • • • •; ' •lyl, •. • ' :
• •
•
Product Approval
Required Moment Resistance
M9
Calculated
Minimum Attachment Resistance
• • . • •• F • • •
••
••
.
• •
Product Approval
Required Uplift Resistance
•.:
1'. •. , . • . .'
- _
.:
Calculated
Average Tile Weight
•
• • • W • • •
•
•
Product Approval
Tile Dimensions
L = length W = width
Product Approval
Alt calculations must be submitted to the buiidng official at the Gi e:of permit application.
. . . . .
• • • •
• •• •• • • • •• ••
••• • • • •• ••• • •
I+ IAM
COUNTY
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Santafe Tile Corporation
8825 NW 95th Street
Medley, FL 33178
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA stall lie trdvitet tb the user by the manufacturer or its distributors and
shall be available for inspection at the sites at:tjij reiieit Qf1e Building Official.
This replaces NOA# 10-1005.15 and consists of pages 1 through 5.
The submitted documentation was raviewad by Atm Tigera. : . • •
• • • •• •••
•• . • •• . • •• • •
• •• • ••. ,•.L%I •
MIAMI•DADE COUNTY
APPROVED
••• • • • • ••• • •
• •• . • • • •
• • • ••• •
•• •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category:
Sub -Category:
Material:
Deck Type:
Roofing
Roofing Tiles
Clay
Wood
1. SCOPE
This approves a roofing system using Santa Fe "Santafe 'S" Clay Roof Tile, as manufactured by Ladrillera
Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Santafe 'S' Clay Roof L = 18"
Tile W= 11.1"
Trim Pieces
1= varies
w = varies
varying thickness
2.1 MANUFACTURING LOCATION
1. Bogota, Colombia
2.2 SUBMITTED EVIDENCE
Test Agency
The Center for Applied Engineering, Inc.
The Center for Applied Engineering, Inc.
The Center for Applied Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
MIAMI•DADE COUNTY
APPROVED
•• ..•
•
• •
• •
•
.• .••
• •••
•• • •
• •• •
•
•• •
• ••
•• •
•
Test
Specifications
TAS 112
TAS 112
Product
Description
One piece high profile clay roof tile equipped with
two nail holes. For nail -on, mortar set and adhesive
set applications.
Accessory trim, clay roof pieces for use at hips,
rakes, ridges and valley terminations. Manufactured
for each tile profile.
Test Identifier
94-156-8
94-156-9
25-7205-1
Project: 07-07-00-91
(307023)
7161-03
Appendix II
7161-03
P.0402 •
.• • • • ••
•
•.
•.
•
• •
•
•
• •
•.
•.
••
•
•
•
• .
•
• .••
•.• • • • • •
• • • • •
• • • •••
• • • • • •
• .• •• • •
000 • • • •
•
• .
• •
•
• •
••
•
• • •
• •
• •
• • •
•• OS
Test Name/Report
TAS 101
TAS 102
TAS 101
TAS 100
TAS 108
(Nail -On)
Static Uplift Testing
TAS 102 & TAS 102(A)
Withdrawal Resistance
Testing of Screw vs smooth
shank nails
Date
Aug. 1994
March 1995
Sept. 1994
Dec. 1991
Dec. 1991
Sept. 1993
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 2 of 5
2.2 SUBMITTED EVIDENCE
Test Agency Test Identifier Test Name/Report Date
Redland Technologies P 0647-01 TAS 108 Aug. 1994
(Mortar Set)
Redland Technologies P 0631-01 PA 108 July. 1994
(Mortar Set)
Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999
IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999
PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02
IBA Consultants, Inc. 2353-70 TAS 101 09/22/03
IBA Consultants, Inc. 2353-71 TAS 101 09/22/03
IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard
RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight -W (Ibf)
Length -I (ft)
Width -w (ft)
Santafe `S'
6.7
1.5
0.958
MIAMI•DADE COUNTY
APPROVED
•
. . .
• .
•
.. ... .. . . . ..
• ... . •
.. • .... . . .
.. . .... •
...
.. •• • . . •. . • • •
. ..••
. . •
. • .. .
.....•
•
...
•
•
•
•
...
• .. ... . •
• • . . . .
• ... .. .
• . . . • • • •
• .. •• • • .. . .
• • ••• • •
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 3 of 5
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
Table 2: Aerodynamic Multiplyers— ,(ft3)
3":12"
Tile
5":12"
X (ft3)
X (ft3)
Battens
Profile
Battens
Batten Application
Direct Deck
Santafe 'S'
Battens
Direct
Deck
0.274
0.297
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Santafe 'S'
5.93
5.90
5.85
5.82
5.73
5.69
5.56
5.53
5.32
5.29
5.03
5.00
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Nail -On Systems
Tile Profile
Fastener Type
Direct Deck
Battens
Santafe 'S'
2-10d Ring Shank Nails
21.8
N/A
One #8 Screw
29.161'1
N/A
Two #8 Screws
38.28'
N/A
One #8 Screw w/ Clip
57.3112
N/A
Two #8 Screws w/ Clip
57.60'
61.77'
1. Approved screws as noted 'Product manufactured by others'.
2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Santafe 'S'
Tile Bond
38.9'
Polyfoam Polypro AH 160T""
28.54
2 See manufactures component approval for installation requirements.
3 Flexible Product, Inc. Average weight per patty 10.4 grams.
4 Polyfoam Product, Inc. Average weight per patty 9.4 grams.
Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Sing e Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Santafe 'S'
Polyfoam Polypro AH 160TM'
63.8'
Polyfoam Polypro AH 160T""
61.96
5 Paddy placement of 63 grams of Polypro AH 160T"".
6 Paddy placement of 24 grams of Polypro AH 160T"".
•• ••• • • •
••
MIAMI•DADE COUNTY
APPROVED
•• •
• •
••. •
••• • • • • ••. • •
•• • • • •• • • • •
•
• • • • • • • • •
• • • • • • • • • .
• •• •• • • • •• ••
••• • • • ••• 0 •
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 4 of 5
Table 6: Attachment i,esistpniog 4xpripised as a Moment - Mf (ft-Ibf)
for Mortar or Azthestvg $et Systems
Tile
Profile
Tile
• • • •; • Application : • • •
Attachment
Resistance
Santafe 'S'
• •: : • RAd'rtdr Set • • : :
23.6
MIAMI•DADE COUNTY
APPROVED
•• •
• •
••. •
••• • • • • ••. • •
•• • • • •• • • • •
•
• • • • • • • • •
• • • • • • • • • .
• •• •• • • • •• ••
••• • • • ••• 0 •
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 4 of 5
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami -Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
,/
18"
PROFILE DRAWING
When using one screw
use this hole.
MIAMI•DADE COUNTY
APPROVED
"SA.IsttAIS;' Y .AY RQOF.TILE
•
• •• . . • • .•• •
E IPTIHS A(!CN' FAlkiCE
• ••. •
• .•. . . . •'.
'•• •• • • • •
.. . •
• • •• . . .• •• . .
• •
... • .. . •..
• • • • •
. •
• • ••. •
• • . • ... •
• •• •• . . •
•.. •
• • .•.
•
•
•
• ••
•
NOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 5 of 5
COUNTY
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
3M Company
3M Center Building 0220-05-E-06
St. Paul, MN. 55144-1000
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTM 2 -Component Foam Roof Tile Adhesive All -160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site �t•hesequest of the j3 ildij Official.
This renews and revises NOA# 11-0124.04 and Fens •rs s ofae$ tljroup 7.
The submitted documentation was reviewed by Alex Tigera. • • •
MIAMI•DADE COUNTY
APPROVED
• ...
•.
• • •
••
%lf
••�tff'i� •• :
ROOFING COMPONENT APPROVAL:
Category:
Sub Category:
Materials:
Roofing
Roof tile adhesive
Polyurethane
SCOPE:
This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as
determined by applicable building code, does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles
system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a
moment based system for single patty placement, and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product
Dimensions
3MTM 2 -Component Foam N/A
Roof Tile Adhesive AH -
160
Foam Dispenser RTF 1000 N/A
ProPack® 30 & 100 N/A
Test
Specifications
TAS 101
Product Description
Two component polyurethane foam adhesive
Dispensing Equipment
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160
roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
Closed Cell Content
MIAMI-DADE COUNTY
APPROVED
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2127
ASTM E 96
ASTM I7 2126:
•• . ..
.• .••
Results
1.6 lbs./ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
• • •+9.07%•Volume Change @ -40° F., 2 weeks
: :+b.11%•yolume Change @158°F., 100% Humidity, 2
• weeks.. •
ASTM D 2856 86%
• •..
• • •• • •• . ••
••••..• •
•
•
•
•
..••••. •.•. • • • .
.. .
... •
• • .
• • • •. • •
• • .. •
•• • .
.•. ..• •.• • • • ••• ••
• 000 • •
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-1PA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB -589-631
9637-92
01-6743-011
01-6739-062b[1]
7050.02.96-1
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Report
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
ASTM E 108
ASTM E 108
ASTM E 84
TAS 114
TAS 101
TAS 101
Date
04/08/94
12/16/96
10/25/95
11/02/95
12/12/95
02/01/94
04/30/93
11/16/94
01/16/95
03/14/96
10/23/98
12/28/98
TAS 101 03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
r-�
F
- W ••• ••. . . . • . ••
• •
••••••
•'
• •• • • • •••
• ••
•• ••• •Y •.• • • •.•
F'— `2l
MS
MIAMI•DADE COUNTY
APPROVED
• ••.
•• • • •
• •• •• • • •
• . • • • • •' • •
..• . • •••
• • • • •
• .••
•
••• 1
• . • ••• • •
• • •
•
• ••• • •
• • • • • • •• •. •
•
.•. •• •• • •• ••••
• • .•.
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160.
2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient
attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in
compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH -
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0
(B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or
ProPack® 30 & 100 dispensing equipment only.
7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2 -
Component Foam Roof Tile Adhesive AH -160 has been dispensed.
9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in
accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted
herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Single Paddy Weight
Min. (grams)
Two Paddy Weight per
paddy Min. (grams)
Flat, Low, High Profiles
#1
35
N/A
High Profile (2 Piece Barrel)
#1
17/side on cap and 34/pan
N/A
Flat, Low, High Profiles
#2
24
N/A
Flat, Low, High Profiles
#3
8
MIAMI•DADE COUNTY
APPROVED
•
•• ••• • • o • • • o ••
•
•• ••• •• • • • ••
• •..
•• . . • •
• • • .••• •
• • •
... •
•�• ` • •••• ••
• • ••. •
••• • • • •••. •
•
• • • ••• • • •
•
• • • • • • • • •
•
• •• •• .• • •• ••
•••
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 4 of 7
LABELING:
All 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Nail through plastic cement
Underlayment
Paddy (Beneath Tile)
10 in:
Eave Course
Eave course only:
Keep adhesive approx.
4 in. up from weepholes
Eave course only:
Keep adhesive approx.
4 in. up from weepholes
jitg;
1) Place enough adhesive to achieve 17 to 23 Optional 2x4's for
square inches in contact with the pan tilesteep pitch applications
2) Tum covers upside down Plae'*44*-'4°#$/"°
4101
Th 1 in. From outside edge ofThen irrstaN the tile.UndertaymeM
.,4*9 $.4 *7.0)00.
•
1
or t
portion ����
e eave
cover tile.
.�1vI��
MIAMI RADE COUNTY
APPROVED
•• •.•
• •
• •
• •.
• •
•• •••
Fascia
Eave closure
Drip edge
Nail through plastic cement
Remov
of th
course
Abut to second course of
• pan tiles. Ensure eave end of
• aadltver les tte
•6pshatease lige. • •
Fav idmirre • • • ',taphole Fascia Bo
•i•s• • •
Sheathing
Optional
Point -up Mortar
on longitudinal
edges of the
• ••• • • • •
• • • • • • • • • •
• • • • • • • • • •
. • • • • • • • • • •
• • • • • • • • • •
•• • • • ••• •
... . . . • • • • • .
• • • . . . • •
• • . .. • • . •
• • . • • • • • • •
• .. .. . . • .• ..
0.. . • • 0.. . .
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
Nail through plastic cement
r
,
Underlayment
1
2 in.
Eave Course
Paddy (Beneath Tile)
Fascia
/�• Weephole
Eave closure
Drip edge
Nail through plastic cement
Underlayment
Paddy (Beneath Tile)
7 in:
Eave Course
MIAMI-DADE COUNTY
APPROVED
Fascia
•• •.. . • • • . ••
• • •
• • • •
•
•• ••• •• • • • ••
• ••• • • • •
• • • • • • • • • •
• • • • • • • • • •
•• • • • • • • • • •
• •• • • • • • • •
•• • • • ••• •
••• • • • • ••• • •
• • • • • • • •
• • • ••• • • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
Eave Closure
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nail through plastic cement
Paddy
(between tile)
Paddy
(under tile)
3in.
x3in.
Single paddy on
under-
layment
Single paddy
under tile
Single paddy
on top of tile
Eave course
2 in. X 7 in. medium
size paddy eave
Fascia course only
MIAMI•DADE COUNTY
APPROVED
Nail through plastic cement
Nail through plastic cement
Underlayment
1
Single paddy under tile
Single paddy between tile
2 in. x 7 in. medium
size paddy eave
course only
?un.x 3in.
4in.
Single
paddy on
under-
layment
Single paddy
on top of tile
Eave
Course
Single paddy
between tile
/S. 3in.x3in.
Single paddy
on underlayment
Single paddy
on top of tile
Eave Course
Eave Closure
2 in. x 7 in. medium
size paddy eave course only
Fascia
END Qv XiliS.ACCEPTANCE
•••••...•
. •
•
. •• • • •
.. •.• •• • • • ••
• ••• • • • •
• • • • • • • • • 1
• • • • . • • • • •
•• • • • • • • • • •
• •• • • • • • • •
.• • • • ••• •
••• • • . ••• • •
• • • • • • •
•. ••• • • •
• • • • • • • . •
• •. • • • • •. ••
••• • • ••• • •
Fascia
Weephole
Eave closure
Drip edge
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 7 of 7