Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REV-16-2431
Miami Shores Village Building Department BUILDING PERMIT APPLICATION 0BUILDING 0 ELECTRIC n ROOFING QX PLUMBING 0 MECHANICAL n PUBLIC WORKS JOB ADDRESS: 652 N.E. 105 St. City: Folio/Parcel#: Occupancy Type: Miami Shores 11-2231-012-0140 Load: Miami Shores, Florida 33138 4 Fax: (305) 756-8972 E NUMBER: (305) 762-4949 SEP 1 2016 ---- FBC 20 Master Permit No./K1--\/-1-CC— 2N 31 /12c.rS._ Sub Permit No. PL1677 231t5 REVISION U EXTENSION El RENEWAL ,RE CHANGE OF El CANCELLATION ci SHOP CONTRACTOR DRAWINGS County: Miami Dade Zip: 33138 Is the Building Historically Designated: Yes NO Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Kiluan, Inc Address: 652 N.E. 105 St. City: Miami Shores State: Florida Zip: 33138 Tenant/Lessee Name: N/A Email: Phone#: Phone#: CONTRACTOR: Company Name: Della Rossa Plumbing Address: 5140 SW 20 St. City: Plantation Phone#: (954) 479-4270 State: Florida Qualifier Name: Joseph Della Rossa State Certification or Registration #: CFC 1427740 DESIGNER: Architect/Engineer: Address: 370 N.E. 101 St. Victor Bruce Phone#: Certificate of Competency #: Phone#: (305) 310-5030 Zip: 33317 (954) 479-4270 City:Miami Shores State: FI. Zip: 33138 Value of Work for this Permit: $ 0 Square/Linear Footage of Work: 40 L/F Type of Work: n Addition n Alteration 0 New Li Repair/Replace Demolition Description of Work: Change gas Zine from Galanized to Underground Gas Polyethylene Piping Specify color of color thru tile: Submittal Fee'$. Permit Fee $ • CCF $ CO/CC $ Scanning Fee $ q • Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise 117 good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Kiluan, Inc. Marco Bruzzi Signature Joseph Del Si OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The forego' g instrument was acknowledged before me this ,,e 3 day of T'1 0G10� , 20 ICO , by 514r day s�ff !7o LVr , 20 1 C , by known to 1-4 G 1r -cc) yu Z.Z 1v , who is ersonally Known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: / // Luc* 'Lis, Sign: Print: Seal: LUCIA G ISASI MY COMMISSION #FF182628 EXPIRES December 10, 2018 APPROVED BY (Revised02/24/2014) I/OWL Peq oSgkwh me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Z�_ '!_Jc'v'� Print: 1.--6 y' t 11 -'-v`' • Seal: ***************** Plans Examiner Structural Review 1PPC'P4 •' LAUREN BAROFSKY t`+ 1 , ,:= MY COMMISSION #FF171017 ;.•' EXPIRES October 22, 2018 IhRi 41f0****Rior1dtiM 1yekrTOcifteth***'**** as Zoning Clerk DICK SCOTT,. GOVERNOR KEN L4' STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD The PLUMBING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date. AUG 31, 2018 N, SECRETARY DELLA ROSSA, JOSEPH ALFREDO DELLA ROSSA PLUMBING & SOLAR LLC 4332 PETERS RD UNIT D&E PLANTATION ISSUED: 06/20/2016 DISPLAY AS REQUIRED BY LAW BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S Andrews Ave.. Rm. A-100, Ft. Lauderdale. FL 33301•1395 954-831-4000 VALID OCTOBER 1, 2016 THROUGH SEPTEMBER 30, 2017 DBA: Business Name: DELLA ROSSA PLUMBING & SOLAR t:... Receipt Itit ataiwa LWN SP L/cCN Business T hAC Ype, i PLUMBING & SOLAR Owner Name: JOSEPH ALFREDO DELLAROSSA Business Opened:07 /07/2ooa Business Location: 4332 PETERS RD StatelCounty/CertJReg:c:?c1427740 PLANTATION Exemption Code: Business Phone: 954-479-4270 Rooms Number of Machines: Employees 1 Machines Professionals For Vending Business Only Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Pnor Years Collection Cost Total Pad 27.00. _. -O. Q@_ ...... ....--E> =$4-. 0. 043.-- .. _.... Q.,.00._ 0 . 00 27.00 - THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT WHEN VALIDATED This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: JOSEPH ALFREDO DELLAROSSA 4.332 PETERS RD -PLANTATION. FL 33317 Receipt 01CP- 3-u.2!1 Paid 07/22/20 ;7.00 2016 - 2017 I � j Gast* RE ,TVEIT SEP 1 2016 The System is the SolutionTM eflAPOI Underground Gas thylene (PE) Piping Installation Guide February, 2011 • 11110..r. .1H�IH S' 1VH3CI8 TIV I --U L.-Mr:Yr,: • •• • • • •• • • • • • • • •• • •• • • • • • • CB • • i. lt • • • • • • •• ffivf46' Featuring thb tboiaLtabib. Seal® Fittings •• • • • •• •• •• •• • • •• •• • •• • • • • • ••• •t• • •• • Afrff from Continental Industries, Inc. ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • TECHNICAL DATA PE -12 PE -16 -IPS 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Average OD .625 1.050 1.125 1.315 1.660 1.900 2.375 7.0 11.0 11.5 11.0 10.0 11.0 11.0 Normal Pipe Size and SDR must be used to match fittings and IPS PE pipe. Nominal Pipe Size and Min. Wall must be used to match fittings and CTS PE pipe. 0.090 0.095 0.099 0.120 0.166 0.173 0.216 Rev.2/2011 Gastite Division 1116 Vaughn Parkway Portland, TN 37148 Toll Free: 1.800.662.0208 Fax: 615.325.9407 Weil: 'vwyr,gastite.com : : 'i:�nii1 ealia@gastite.com . .. . . . . ... . • .. .. . .. • . . • .. .. • ... . .. . • .. . • • .. • .. .. .... .... • • .... • .... . • • . . . • • • .... . • . . . . . . • .. .. . . . • • • • •• Underground Installation Guide ASSEMBLY INSTRUCTIONS: I.D. SEAL° CON -STAB STEP - Verify the polyethylene (P.E.) pipe being assembled is the correct size. STEP 2 Cut pipe ends square. c-. Clean piping thoroughly to assure there is no dirt, grease or oil in assembly area. STEP 4 Chamfer end of pipe using Continental's chamfering tool with I.D. gauge. Mark the stab depth by inserting the pipe into the chamfer tool and marking the pipe at the entrance as shown. STEP 6 If using chamfer tool with ID gauge, check for proper chamfer by inserting pipe over gauge. Stab pipe completely into fitting entrance. STEP 8 Stab pipe completely into fitting so that the mark on the pipe is within 1/8" from the fitting entrance. r;,; Repeat steps 1 though 4 for all Con -Stab joints. STEP 10 To assure proper assembly and to comply with 49 CFR 192 Subpart J -Test requirements, the joint shall be leak tested. See Technical Bulletins 34-6448-00 Each Con -Stab I.D. Seal Fitting & 34-6448-01 for further information prowidas ?he relieving unique regarding I.D. Seal Con -Stab Fittings. fenturps: Two ir.tarncl se,ils • Fixed stiffener • Self-locking gripper • Moisture l:p • Uui-body corstruc,ioci rHue GRIPPER INTERNAL SEAL STIFFENER .lu Lw .• .��I� LiPC. SHELL PE OVERSHOOT Potent #s 5,366,260,5,692,785 & 5,853,272 2 .•.. •• • •;6dstlte•4iyispn b;1 116 Vaughn Parkway • Portland, TN 37148 •-,-v-'-. • • • •-•---• • . • . . . • • • • . ••• • • • • • • • . INSTALLATION GUIDELINES: 1) Polyethylene (PE) gas piping shall be installed outside, underground only. PE is not approved for indoor use or for encasement in concrete. 2) Underground gas piping shall be installed with sufficient clearance from any other underground structure to avoid contact, to allow maintenance, and to protect against damage from proximity to other structures. In addition, underground plastic piping shall be installed with sufficient clearance, or shall be insulated from any source of heat so as to prevent heat from impairing the serviceability and reliability of the pipe. 3) Careful attention should be paid to layout and routing to prevent excessive stressing of the piping where there is heavy vehicular traffic, or soil conditions are unstable and setting of piping could occur. ABS or PVC piping may be used for additional protection. 4) Piping shall be protected from physical damage where it passes through flowerbeds, shrub beds, and any other cultivated areas where damage is reasonably expected. 5) Polyethylene piping shall be installed so as to minimize thrust forces caused by expansion and contraction of the piping. Typical polyethylene piping will expand or contract 1 inch for every 100 F temperature change for every 100 feet of pipe. 6) Piping shall be buried or covered in a manner so as to protect the piping from physical damage and in accordance with the following guidelines. a) Cover Requirements — Underground piping systems shall be installed with at least 18 inches of coverage. The cover may be reduced to 12 inches if external damage to the pipe is not likely to result. If a minimum of 12 inches of cover cannot be maintained, the pipe shall be installed in a conduit or otherwise protected or shielded. b) Trenches — The trench shall be graded so that the pipe has a firm, substantially continuous bearing on the bottom of the trench. It should also be free of rocks and debris that would abrade the PE piping. This may require additional material such as loom, topsoil or sand to create a level surface. c) Backfilling — Where flooding of the trench is done to consolidate the backfill, care should be exercised to see that the pipe is not floated from its firm bearing on the trench bottom. 7) An electrically continuous corrosion -resistant tracer wire (minimum AWG 14) or magnetic tape shall be buried with the polyethylene pipe to facilitate Locating. One end shall be brought above the ground at a building wall or riser. The wire or tape shall not be in direct contact with the polyethylene pipe. 8) The maximum allowable pressure test shall be 125 psi and the maximum continuous pressure shall be 60 psi. Note: The techniques outlines in this bulletin are recommended practice for generic applications. These practices must be reviewed for compliance with all local fuel gas and building codes. Where a conflict exists between these techniques and local requirements, local requirements will take precedence. •• ••• • • • •• •• Con -Stab I.D. Seal" System Specification` Meets:of 11c:ec'.s • NFPA-58 and NFPA-54 • • • • • • • • • • • • •• ••• •• • • • •• • ASTM D-2513, Categor • ASME B31.8-1995 • CAN/GSA-B-137.-4 • Listed with CSA • Listed with IAMPO/IJPC • US DOT Part 192.283 • ISO -437 1 • ...IMPORTANT. GHR+e • • ••• :•IDOF; Tubing Size , NATURAL GAS SIZING TABLES FOR PE PIPE Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 6.0 in. WC and a Pressure Drop of 0.5 in. WC (based on a 0.60 specific gravity gas) 1/2" CTS 3/4" IPS r CTs 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Tubing Length (ft) 15 i 20 ! 25 30 70 110 635 823 1173 2108 2765 5954 74 426 553 787 1415 1900 3997 59 338 438 624 1121 1526 3166 50 286 371 529 950 1306 2683 44 252 326 465 835 1158 2360 39 227 294 419 752 1049 2125 33 192 249 355 638 898 1801 29 169 219 312 561 796 1584 26 152 197 281 505 721 1426 24 139 180 257 462 663 1305 22 129 167 238 428 617 1209 21 120 156 223 400 579 1130 100 125 150 20 113 147 209 376 547 1063 17 100 90 129 116 184 166 331 298 485 439 935 842 16 Tubing Size , 200 250 300 400 Tubing Length (ft) 500 600 700 800 1 900 1000 11100 1200 j 1300 1 1400 1500 1/2" CTS 3/4" IPS 1" CTS 1"IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 13 76 99 141 253 376 714 12 10 9 8 7 6 6 6 5 5 5 5 67 60 51 45 40 37 34 32 30 29 27 26 87 78 66 58 52 48 44 42 39 37 35 34 124 111 94 83 75 68 63 59 56 53 50 48 222 200 170 149 134 123 114 106 100 95 90 86 333 302 258 229 207 191 178 167 157 149 143 137 628 565 479 421 380 347 322 301 283 268 255 243 4 25 32 46 83 131 233 4 24 31 44 79 126 224 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 6.0 to 7.0 in. WC (1/4 psig) and a Pressure Drop of 1.0 in. WC (based on a 0.60 specific gravity gas) Tubing Length (ft) 5 10 15 20 25 ! 30 40 50 1 60 1 70 80 90 100 125 165 947 1228 1749 3143 4023 8878 Tubing Size 200 1/2" CTS 20 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 4 150 111 636 824 1174 2110 2765 5960 88 503 653 930 1671 2221 4720 74 427 553 788 1416 1900 4001 65 375 487 693 1246 1684 3519 59 338 438 624 1122 1526 3169 50 286 371 529 951 1306 2686 44 252 327 465 836 1158 2362 39 227 294 419 753 1049 2127 36 208 269 33 192 249 384 355 689 638 965 898 1947 1803 31 180 233 332 596 842 1685 29 169 219 312 561 796 1586 26 149 193 275 494 705 1395 23 134 174 247 445 639 1256 114 100 90 76 67 147 129 117 99 87 210 184 166 141 124 377 331 298 253 223 547 485 439 376 333 1065 936 843 715 629 8 7 7 7 6 6 60 55 51 48 45 43 41 39 37 36 • 748• • • •72• • 66 • 62 • • 58 55 53 50 48 46 112 ,:02,•: :5: :. Q8 • • 83 79 75 71 69 66 �QQ • •:83' . ; 1'7431 : 1.1i9 • • • 149 141 135 128 123 118 302 278 258 242 229 217 207 199 191 184 • 56/; • • 518• • • 48p 4q • 44122 399 380 363 348 334 • • • • • • • • • • • • • • • •• • • • •• •• • • • • • • •• • • • • • 1000BTUh=1CFH ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • •• •• •• OWN ppvi�ion•;1116 Vaughn Parkway • Portland, TN 37148 NATURAL GAS SIZING TABLES FOR PE PIPE Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 8.0 in. WC and a Pressure Drop of 3.0 in. WC (based on a 0.60 specific gravity gas) 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Tubing Size 400 308 210 166 141 1773 1205 955 809 2298 1561 1236 1048 3275 2198 1741 1476 5885 4002 3170 2686 7290 5010 4023 3443 16623 10940 8665 7344 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2"IPS 2" IPS 250 300 124 712 921 1298 2363 3052 6459 111 641 830 1169 2128 2765 5816 Tubing Length (ft) 40 50 60 i 70 80 94 543 703 991 1803 2367 4930 83 478 619 871 1586 2097 4336 75 430 557 785 1428 1900 3904 Tubing Length (ft) 400 1 500 600 700 800 68 394 510 718 1307 1748 3573 63 365 472 665 1211 1627 3309 900 1000 1100 59 341 441 621 1131 1526 3093 37 33 30 25 22 215 189 171 145 127 279 245 221 187 165 393 345 311 264 232 715 629 566 480 422 991 878 796 681 604 1954 1719 1548 1312 1154 20 113 147 209 375 547 1060 18 103 134 191 343 503 970 17 96 124 177 318 468 898 16 90 116 165 297 439 839 15 84 109 156 280 415 790 14 80 103 147 265 394 748 56 321 415 585 1065 1442 2911 49 282 365 514 937 1278 2560 44 254 329 463 843 1158 2305 1200 1300 1400 i 1500 13 76 98 140 252 376 711 13 72 94 134 241 360 679 12 12 69 67 90 87 128 123 230 222 346 333 651 626 1000BTUh=1 CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 12.0 to 14 in. WC (1/2 psig or Tess) and a Pressure Drop of 6.0 in. WC (based on a 0.60 specific gravity gas) Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 5 10 15 20 25 462 2657 3445 4909 8821 10606 24918 310 1784 2313 3295 5922 7290 16727 Tubing Size 200 250 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 246 1413 1832 2610 4690 5854 13249 300 208 1197 1553 2212 3975 5010 11229 400 183 1053 1366 1946 3496 4440 9877 55 319 413 589 1058 1442 2988 49 280 363 518 930 1278 2628 44 252 327 466 838 1158 2366 37 214 277 395 710 991 2006 Tubing Length (ft) 165 948 1230 1752 3148 4023 8894 140 804 1042 1485 2668 3443 7538 123 707 917 1306 2347 3052 6630 111 637 825 1176 2114 2765 5970 Tubing Length (ft) 500 600 1 700 800 900 33 29 188 169 244 • • 2126. • 348• 313 • 625.. • 5a: 878 796 1764 1589 • • • . . • •. .. • 27 25 23 155 144 134 101 583 755 1076 1934 2544 5464 80 i 90 94 540 700 997 1791 2367 5060 88 504 654 932 1674 2221 4729 100 125 83 475 615 877 1576 2097 4451 73 417 541 771 1386 1859 3915 150 65 376 487 694 1248 1684 3525 1000 f 1100 1200 1300 1400 1500 22 126 • 201 • 136 • 674 164 • . • • •• . . . 'g6 , : 2q : •248 233 •5S5'•`4Z7: •4$5 419 732 681 639 604 . 1 X54 • 1346 ..:125§. 1 184 • . • . • • • . • •• • • •• . • . . . • • •.• • • • • ••• • • • • . • • • • • • . • ••• • • . • Ph: 1.800.662.0208 • Fax: 615.325.9407 • Web: �wwwgtisrita.pbm • , • • + • ; 21 20 120 114 155 147 221 210 397 377 573 547 1121 1066 19 109 141 201 361 524 1018 18 104 135 192 345 503 976 17 100 130 185 332 485 938 1000BTUh=1 CFH 5 NATURAL GAS SIZING TABLES FOR PE PIPE - ELEVATED PRESSURE Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 0.60 specific gravity gas) Tubing Size 1n" CTS 3/4" IPS 1" CTS 1" IPS I-1/4" IPS 1-1/2" IPS 2" IPS Tubing Size 200 250 300 ' 400 500 600 700 800 900 1000 1100 Tubing Length (ft) 1167 6710 8687 12396 22276 25532 62923 10 15 20 25 30 40 50 60 70 ' 80 I 90 100 125 150 783 4504 5832 8321 14953 17548 42239 621 3568 4619 6591 11844 14092 33455 526 3024 3915 5586 10038 12061 28355 463 2660 3443 4913 8829 10689 24940 417 2395 3101 4424 7950 9685 22458 353 2030 2628 3750 6738 8289 19034 311 1785 2311 3298 5927 7347 16742 280 1608 2081 2970 5337 6657 15076 Tubing Length (ft) 256 1471 1905 2718 4884 6124 13797 237 1363 1764 2517 4523 5697 12777 1/2" CTS 3/4" IPS 1" CTS I" IPS 1-1/4" IPS 1-1/2"IPS 2" IPS 140 123 805 708 1042 916 1486 1307 2671 2349 3470 3076 7544 6636 111 637 825 1177 2115 2787 5975 94 540 699 998 1793 2385 5064 83 475 615 878 1577 2114 4455 74 428 554 790 1420 1915 4011 68 391 507 723 1300 1762 3671 63 363 469 670 1204 1639 3400 59 339 439 626 1125 1538 3177 55 319 413 589 1059 1453 2990 53 302 391 558 1002 1380 2831 221 1273 1649 2352 4227 5345 11941 208 1198 1552 2214 3979 5049 11239 183 1054 1365 1947 3500 4475 9885 1200 1300 1400 50 287 372 530 953 1316 2693 48 274 355 507 910 1261 2572 46 263 340 485 872 1211 2464 165 949 1229 1754 3151 4055 8902 1500 44 253 327 467 838 1167 2368 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 5.0 psi and a Pressure Drop of 3.5 psi (based on a 0.60 specific gravity gas) Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-112" IPS 2" IPS 2544 14628 18966 27024 48561 53153 137172 10 1708 9819 12731 18141 32598 36532 92082 200 t 250 15 Tubing Length (ft) 1353 7777 10084 14368 25819 29336 72933 1147 6592 8546 12178 21883 25108 61813 300 400 1008 5798 7517 10711 19248 22253 54370 500 908 5221 6769 9645 17332 20163 48959 600 305 268 242 1754 1543 1389 2274 2000 1801 3240 2850 2566 5822 5121 4612 7225 6403 5802 16447 14466 13027 205 1177 1526 2175 3908 4965 11041 180 1036 1343 1913 3438 4401 9711 162 932 1209 1723 3096 3987 8745 770 4425 5737 8175 14689 17257 41494 677 3892 5046 7190 12921 15294 36498 610 3505 4544 6475 11635 13858 32865 Tubing Length (ft) 70 558 3207 4159 5925 10648 12749 30078 700 800 900 1000 148 853 1106 1577 2833 3668 8003 137 790 1025 1460 2624 3413 7411 128 739 958 1364 2452 3202 6926 121 695 901 1284 2308 3025 6519 517 2970 3851 5488 9861 11860 27855 1100 483 2776 3599 5128 9215 11128 26031 100 454 2613 3387 4827 8673 10512 24500 125 t 150 400 2298 2980 4246 7629 9316 21550 1200 1300 1400 360 2069 2683 3823 6870 8441 19405 1500 114 658 853 1216 2185 2873 6171 109 626 812 1156 2078 2741 5870 104 598 775 1104 1985 2624 5606 100 573 743 1058 1902 2521 5372 96 551 714 1017 1828 2429 5163 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 10.0 psi and a Pressure Drop of 5.0 psi (based on a 0.60 specific gravity gas) Tubing Size 5 10 15 20 25 Tubing Length (ft) 30 40 50 60 70 80 90 100 125 150 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS Tubing Size , 200 3529 2369 1877 20291 13621 10789 26309 17661 13988 37487 25164 19931 67362 45220 35816 72320 49705 39915 190283 127734 101171 1/2" CTS 3/4" IPS 1" CTS 1"IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 6 1590 1399 1260 1068 939 846 774 9144 8043 7242 6138 5399 4862 4449 11856 10428 9390 7958 7000 6303 5769 16893 14858 13380 11340 9974 8982 8220 30355 26700 24043 20377 17923 16139 14770 34162 30277 27433 23479 20809 18855 17346 85746 75421 6191,5 •5Z5 J :5491; :4' i9Q • •41723 • 717 4120 5342 7612 13679 16137 38639 670 3851 4993 7114 12783 15141 36109 630 3624 4699 6696 12032 14302 33987 Tubing Ler.gt;i (,t) 250 ' 300 t 400 500 7-700 8G3 830 1000 1100 1200 1300 423 372 335 284 250 225 206 191 178 168 2433 2140 1927 1633 1437 1294 1184 1096 1025 964 3154 2775 2498 2118 1863 • •167'/;' 1535: • 1421. 13286 • r260 4495 3953 3560 3017 2654 • •?.390; 2.187: 42/ • 1493.:1132 8077 7104 6397 5422 4769 4294• • 3930 • • 3Ggi3 34(116 •3201 9830 8712 7894 6756 5988 ••5425• 4991 4643 4357 4115 22815 20067 18070 15315 13471 12130 11101 10281 9608 9043 ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • •• •'' • •• •aci titg pjvij'ien• ;1116 Vaughn Parkway • Portland, TN 37148 159 913 1184 1686 3031 3908 8561 151 868 1126 1604 2883 3729 8143 144 829 1075 1532 2753 3571 7777 554 3188 4133 5889 10583 12676 29894 499 2871 3722 5303 9530 11485 26919 1400 1500 138 795 1030 1468 2638 3430 7452 133 764 990 1411 2536 3305 7162 1000BTUh=1CFH 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 1/2" CTS 3/4" IPS 1" CTS I" IPS 1-1/4" IPS 1-1/2" IPS 2° IPS Tubing Size i 5 LP GAS SIZING TABLES FOR PE PIPE Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 11.0 in. WC and a Pressure Drop of 0.5 in. WC (based on a 1.52 specific gravity gas) Tubing Length (ft) 187 1073 1391 1983 3563 4724 10063 22 129 167 238 427 642 1207 125 720 934 1331 2391 3247 6755 20 113 147 209 376 569 1061 15 99 571 740 1054 1894 2608 5351 18 102 132 188 338 516 956 20 25 30 40 50 60 70 84 484 627 893 1605 2232 4535 15 86 112 160 287 441 810 74 425 551 786 1412 1978 3989 67 383 497 708 1272 1792 3592 56 325 421 600 1078 1534 3044 50 286 370 528 948 1359 2678 45 257 333 475 854 1232 2411 41 235 305 435 781 1133 2207 80 38 218 283 403 723 1054 2044 90 35 204 264 376 676 989 1910 100 33 192 249 354 636 934 1797 125 29 169 219 311 560 828 1581 150 26 152 197 280 504 750 1424 13 76 99 140 252 391 712 12 68 89 126 227 354 642 11 63 81 116 208 326 587 10 58 75 107 192 303 544 9 54 70 100 180 285 508 9 51 66 94 169 269 478 8 48 63 89 160 255 453 8 46 60 85 152 244 431 8 44 57 81 146 233 411 7 42 54 78 140 224 394 7 40 52 75 134 216 379 2516BTUh=1CFH Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1.1/2" IPS 2" IPS Tubing Size ; 200 1966 11300 14652 20877 37514 43429 105963 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2"IPS Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2' IPS 2" IPS Tubing Size 1/2" CTS 3/4" IPS 1" CTS 1" IPS 1-1/4" IPS 1-1/2" IPS 2" IPS 236 1355 1757 2503 4498 5903 12705 5 2476 14234 18455 26296 47252 53960 133476 10 15 20 25 1319 7586 9835 14014 25183 29848 71131 250 207 1192 1545 2202 3956 5232 11175 1045 6008 7790 11100 19946 23969 56339 886 5092 6602 9408 16905 20515 47750 300 400 187 1073 1391 1983 3563 4740 10063 158 910 1179 1680 3019 4057 8529 779 4479 5807 8275 14869 18182 42000 500 139 800 1037 1478 2656 3596 7502 30 702 4033 5229 7451 13389 16474 37820 600 125 720 934 1331 2391 3258 6755 Tubing Length (ft) 40 595 3418 4432 6315 11348 14100 32054 50 523 3007 3898 5555 9982 12496 28194 60 471 2707 3510 5002 8988 11322 25388 Tubing Length (ft) 700 115 659 855 1218 2189 2997 6182 800 106 611 792 1128 2027 2788 5725 70 431 2478 3213 4578 8226 10417 23234 900 1000 99 571 740 1054 1894 2616 5350 399 2295 2975 4239 7618 9691 21517 373 2144 2780 3962 7119 9092 20108 100 125 150 351 2018 2617 3729 6700 8589 18926 309 1775 2302 3280 5894 7612 16647 278 1599 2073 2953 5307 6897 14990 93 537 696 992 1783 2471 5036 1100 88 508 659 939 1688 2347 4767 1200 84 484 627 893 1605 2239 4535 1300 1400 80 462 599 853 1533 2144 4331 77 443 574 818 1469 2060 4150 1500 74 425 551 786 1412 1985 3988 2516BTUh=1 CFH Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 10.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) 10 15 20 25 1662 9555 12388 17652 31720 37087 89601 1316 7568 9812 13981 25123 29782 70967 1116 6414 8316 11849 21293 25489 60148 981 884 5642 5080 7315 6587 10423 9385 18729 16865 22591 204651. 5294 4764( • 200 250 300 400 500 600 297 1707 2213 3153 5665 7334 16004 261 1501 1946 2773 4983 6500 14077 235 1352 1753 2497 4487 5890 12676 199 1146 1485 2116 3803 5041 10743 175 158 1008 •807 14 1:76 1862; 146 • 33115 3012 4468 4048 9449 8509 ••• • • • • • Tubing Length (ft) 749 659 593 4306 3787 3410 5583 4910 4422 7954 6997 6300 14294 12572 11321 4175.19 •15517. 14048 146: 5 4: 980 • • • • ••• • 543 3121 4047 5766 10361 12943 29267 503 2890 3747 5340 9595 12041 27104 Tubing Lenoth (f+) 700 i 800 1 900 11000 1100 90 470 2701 3502 4990 8967 11297 25329 144 134 125 118 111 0430 • 769 •919 • •676 640 1:4177 • ?97 i • 93) • 877 830 444 : :4f1 : 1250 1183 257 '2553 •2386. 2246 2126 3724 3465 3251 3071 2916 • 787 • 721a • 6739 6343 6005 • • • • • • • • ••• • • • • Ph: 1.800.662.0208 • Fax: 615.325.9407 • Web: rtigaslite!ciem • • • • • • • 100 125 150 442 2542 3296 4697 8440 10671 23840 389 2236 2899 4131 7423 9458 20970 350 2014 2611 3720 6685 8569 18882 1200 1300 1400 1500 106 609 790 1125 2022 2782 5712 101 582 754 1075 1931 2664 5455 97 557 723 1030 1851 2560 5227 93 536 695 990 1779 2466 5024 2516BTUh=1CFH 7 Bauhaus Engineering, 1595 SW 154TH Court Miami FL 33194 Tel. 786-246-4651 • Fax 305-397-0354 SHOP DRAWING REVIEW PROJ. No: 15-0018 REVIEWER: Edwin Cerna DATE RECEIVED: 08/30/16 PROJECT NAME: BRUZZI RESIDENCE POOL RENOVATION DATE RETURNED: 08/30/16 GAS PIPING Gas Piping Submittal Review is limited to do not constitute a contract codes and regulations. solely responsible Date: ❑ verifying general modification No detailed check for confirming all ensuring 08/30/16 SUBSTANTIALLY SUBSTANTIALLY DOES NOT UNRESPONSIVE REVIEWED conformance with the design concept as presented by the contract documents. Notations and do not relieve and contractor from compliance with contract documents, governing of quantities or dimensions was made. The general contract/construction manager is quantities, dimensions, fabrication techniques, coordinating work with other trades and that work is performed in a safe and satisfactory manner. BY: E. CERNA CONFORMS TO DESIGN CONCEPT .... ACCEPTED AS SUBMITTED CONFORMS TO DESIGN CONCEPT .... ACCEPTED AS NOTED CONFORM TO DESIGN CONCEPT .... REVISE AS NOTED AND RESUBMIT SUBMITTAL AS NOTED .... REJECTED, REVISE AS NOTED AND RESUBMIT AND RETAINED FOR INFORMATION ONLY A ❑ ❑ ❑ NO. COMMENTS 1 Provided alternate piping material for gas piping installation is acceptable. Polyethylene piping size for new branch under this project should remain unchanged. 3/4". FBC 402.4(21). Underground sleeve requirements under this project remain unchanged. Edwin Cerna, PE 69808 08-30-16 ��utu11Itii �%%0•��N O. C,;?1',,� :.` <(9.. • G�E N s '.�� _• Nn F,QRnR• :-0