Loading...
REV-16-1519BUILDING PERMIT APPLICATION Miami Shores Village Budding Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 )762-4949 !`1 FBC 20 Ik-t s4 ster Permit No. lc Sby Sub Permit No. PEN 16 - 1519 BUILDING ❑ ELECTRIC ❑ ROOFING *REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: (26 5 tri Gs 5-1- City: I City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 1/ — 32 86— dy y aZO Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titlgholder): ' moi- °- '' ' 1.41--"�'1 Address: 49'92- Ne 95 Sr” Phone#: (3o5-)` (z-3(1418 City: '7) "bi/ S''''S State: - zip: 33 / 3Cis Tenant/Lessee Name: Phone#: Email: /2'03-4--r" er G r- / �✓"1 CONTRACTOR: Company Name: 'L'p/vs'JyWCA"jor) ?t -o.1' Address: 2-81/ ttre- 7-1-1' U ,(V Phone#: Ca(-) g3 --19° City: ,1//4Y?' 6:01 -it— S State: Qualifier Name: a -O PLA'S'0-4,4 State Certification or Registration #: SGC' 15/2 4'OO DESIGNER: Architect/Engineer: 65°P/7M Address: bly A/ 3�S'r zip: v3.16(i Phone#: ?J— /9 C/2- Certificate ZCertificate of Competency #: Phone#:(2 ') 57X-' 0'1°11 City: /7/" / State: FL- Zip: 33 i 3� Value of Work for this Permit: $ (73-0D D Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: A/6A/ tge'4'1 h rife S • J 2 0/ n Jz Specify color of color thru tile: Submittal Fee $ Permit Fee $ ?b •GK CCF $ CO/CC $ Scanning Fee $ " i • GC) Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ 1 GO • Bond $ TOTAL FEE NOW DUE$ /- CA (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person -whose property is subject to attachment. Also, a certified copy of -the -recorded notice of commencement -must -tie -posted at the fob ite for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT Signature CONTRACTOR The foregoing instrument was acknowledged before me this The foregoin: instrument was acknowledged before me this D, day of c/U"'� , 20 14' , by day of d.'t t , 20 Xeb .y , who is personally know to me or who has produced ''34r r^-4-4' as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: +SASANABRIA ommission My Commission Expire,, July 1 8, 201 7 *********************************** APPROVED BY (Revisedo2/24/2014) me or who has produced , who 4-06-k-4-/ 0 identification and and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: to as * ************************************************************* Plans Examiner Structural Review Zoning Clerk MUS STRUCTURAL DESIGN LLC CONSULTING ENGINEERS 7850 NW 146 Street, Suite 305 Miami Lakes, F1 33016 T. (305) 512 5860 F. (305) 512 5861 www.optimussd.com l5- 5691 p�I6- rst'i R`_ ' TED JUN 2 2 2016 BY: Project Name and Address Project Owner and Address Frehling Residence 1285 N.E. 95th St. Miami Shores, F133138 Frehling Residence 1285 N.E. 95th St. Miami Shores, F133138 COVER PAGE DATE: May 18, 2016 TO: Juan Calvo, Oppenheim Architecture — via email FAX: CC Carlos Sanabria, Tech Construction Group - via email Roger Plasencia, Tech Construction Group - via email Jose A. Gutierrez, Optimus — via email Lyla Velosa, Optimus — via email Mohammad Taghioff, Optimus — via email FROM: Tanya Homleid, P.E. PROJECT NUMBER: Frehling Residence RE: Inspection Report #15 Frehling Residence COMMENTS: PERMIT #: Miami Shcres Village APPROVED ZONING DEPT BLDG DEPT BY DATE «E6T ro C MPUF WITH i >T� ANL) U IjN tY r{ LES AND REGULATIONS C Tb PY US STRUCTURAL DESIGN LLC CONSULTING ENGINEERS 7850 NW 146 Street, Suite 305 Miami Lakes, F133016 T. (305) 512 5860 F. (305) 512 5861 www.optimussd.com Project Name and Address Project Owner and Address Frehling Residence 1285 N.E. 95th St. Miami Shores, F133138 Frehling Residence 1285 N.E. 95th St. Miami Shores, F133138 INSPECTION REPORT: #15-Frehlinj Res. DATE:5/18/2016 � Weather conditions: 88 °F ITEMS INSPECTED LOCATION REFERENCE Inspected chipped out sections at the underside of roof beams on terrace area of the second floor. Roof Beams Structural Drawings. COMMENTS LOCATION STATUS The underside of (2) 8"x 18" roof concrete beams were chipped out by the contractor approximately 3/4" deep and about 4" wide to install 1'x2" furring strips for installation of ceiling cedar wood finish. There were no exposed rebars observed at all the chipped out sections. To verify the concrete clear cover at the underside of the beams, safe2core performed a concrete scanning process using ground penetrating radar to locate the rebars. According to the report provided, the concrete clear coverage in the beams are 3" bottom and top and 2" at the side. Roof Beams Typical repair details are During the inspection we observed that metal chairs were cut in attached. Further investigation and inspection are required some locations. These are incorrect type of chairs without anti- corrosion tip that were installed at the bottom of concrete beams. during the repair process. The project manager was advised, that these chairs shall be cut back, applied with anti -corrosion coating and patched with approved repair mortar, and will be re -inspected after all repair work is completed. Attached are photos for reference and scanning inspection report from safe2core. INSPECTED BY: TanyaHooile Special Inspec CONCRETE SCANNING • CONCRETE CUTTING • UTILITY LOCATING May 16, 2013 Tech Construction Group, Inc. 284 Westward Dr. Miami Springs, FL 33166 Project: 1285 NE 95 Street Miami Shores, FL GROUND PENETRATING RADAR INSPECTION REPORT Safe2core performed a Ground Penetrating Radar survey on a 18" x 8" thick tie beam, on the second floor at the above mentioned project. The (4) areas inspected were 2' long, the purpose of the inspection was to located the parallel bars at the bottom of the beam, rebar spacing and concrete cover around the existing bars. TECHNOLOGY: Ground Penetrating Radar (GPR) GPR works by sending a tiny pulse of energy into a material and recording the strength and the time required for the return of any reflected signal. A series of pulses over single area make up what is called a scan. Reflections are produced whenever the energy pulse enters into a material with different electrical conduction properties or dielectric permittivity from the material it left. The strength, or amplitude, of the reflection is determined by the contrast in the dielectric constants and conductivities of the two materials. While some of the GPR energy pulse is reflected back to the antenna, energy also keeps on traveling through the material until it either dissipates or the GPR control unit has closed its time window. (Figure the rate of signal attenuation varies widely and is dependent on the properties of the material thought which the pulse is passing). Concrete Scanning using GPR Technology Using the principals described above, Safe2core Applies GPR Technology to concrete to locate rebar, Post -Tension cables, conduits, and any other embedded targets in 14262 SW 140th St., Ste. 104, Miami, FL 33186 ■ PH (786) 254-5451 ■ Fax (786) 465-6768 CONCRETE SCANNING • CONCRETE CUTTING • UTILITY LOCATING concrete structures. All scans are performed up to the capabilities and technology limitations of Ground Penetrating Radar. EQUIPMENT All locations were inspected using Ground Penetrating Radar (GPR) Technology with a GSSI Model SSMINI equipped with a 1.6. Equipment FCC complaint, FCC ID QF7MINISIR and/or 1000 MHz Palm Antenna. RESULTS: Beam: 18" x 8" thick. Rebar: Horizontal bottom rebars have 3" concrete cover ( bottom of the beam ). Stirrups spacing is 6" approx. Should you have any questions, do not hesitate to contact me at (786) 254-5451 Respectfully inspected & submitted, INSPECTED BY: Alvaro " Balo " Simpson *Certified GSSI Ground Penetrating Radar Technician *Certified Post -Tension and Concrete Inspector ( Post -Tension Institute ) *Certified Concrete Coring and Drilling Tech i Safe2core Phone: 786-254-5451 Email: balo@safe2core.net Website: www.safe2core.net 14262 SW 140th St, Ste. 104, Miami, FL 33186 ■ PH (786) 254-5451 ■ Fax (786) 465-6768 safe2core CONCRETE SCANNING s CONCRETE CUTTING • UTILITY LOCATING Please see following pictures showing existing rebar location: Image A A.2 14262 SW 140th St., Ste. 104, Miami, FL 33186 • PH (786) 254-5451 ■ Fax (786) 465-6768 CONCRETE SCANNING * CONCRETE CUTTING • UTILITY LOCATING Image B B.1 B.2 imp 14262 SW 140th St., Ste. 104, Miami, FL 33186 • PH (786) 254-5451 • Fax (786) 465-6768 CONCRETE SCANNING • CONCRETE CUTTING ® UTILITY LOCATING Image C C.1 C.2 14262 SW 1401" St., Ste. 104, Miami, FL 33186 r PH (786) 254-5451 • Fax (786) 465-6768 CONCRETE SCANNING • CONCRETE CUTTING r UTILITY LOCATING Image D D . 1 D.2 - - 14262 SW 140th St., Ste. 104, Miami, FL 33186 a PH (786) 254-5451 a Fax (786) 465-6768 Existing Condition Moderate span (see note 1) Step 1 Saw cut around perimeter of spall Chip out to sound concrete (see note 2) Step 2 Coat exposed surface coated with CR246 Sto Bonding and Anti -Corrosion Agent (see note 3) Step 3 Fill prepared area with Sto CR702 Overhead Mortar (see note 4) Step 4 Protect surface with appropriate coating Notes: 1] Moderate spalls are chipped deeper than 1/4" (7 mm) with some aggregate loss, but no exposed re -bar. 2] Pressure wash after excavation to remove dust, laitance, and other bond inhibiting materials, SSD substrate. 3] Apply a 20 mil coating of CR246 Sto Bonding and Anti -Corrosion Agent onto the prepared SSD surface to insure proper bond of the repair material. 4] Fill excavation with Sto CR702 Overhead Mortar, consolidate, finish and cure as required. 5] Apply protective coating to prepared substrate. 6] For Sto material selection, physical properties. mixing, application and curing information refer to appropriate Sto Technical Bulletins. (-6 OVERHEAD CONCRETE SPALLS - MODERATE SCALE • N.T.S.