Loading...
DGT-12-2168 (2)Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 185748 Permit Number: DGT -11 -12 -2168 Scheduled Inspection Date: February 20, 2013 Inspector: Bruhn, Norman Owner: ARNOLD, WILLIAM Job Address: 746 NE 94 Street Miami Shores, FL 33138- Project: <NONE> Contractor: OUTDOOR LIVING INC Permit Type: Decks /Gazebos/Trellises Inspection Type: Framing Work Classification: Pergola Phone Number Parcel Number 1132060141660 Phone: (561)310 -6081 Building Department Comments pergola 16 x 18 Infractlo Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP - 184796. CREATED AS REINSPECTION FOR INSP - 184752. CREATED AS REINSPECTION FOR INSP- 181605. NEED LETTER FROM ARCHITECT REGARDING CLIPS USED AND CUT OUT ON 2 X 12 COLUMS OK TO COVER. JR 4x 12 missing. Provide revision with calculations for all changes. NB NO REVISION FOUND. JR Attic/ February 19, 2013 For Inspections please call: (305)762 -4949 Page 16 of 38 DZN ARCHITECTURE ENGINEERING CONSTRUCTION 13 February 2013 Building Inspector Miami Shores BIdg.Dept. 10050 NE 2"d Avenue Miami Shores, FI. 33138 Re : Gutter Pergola 746 NE 94t Street Miami Shores, FI. 33138 Permit: 12 -2168 Dear Sir / Madam : Please be advised of the following : The replacement hurricane anchor strap specified in place of the hurricane anchor clip in conflict with the beam / post connection is a : Nu Vue NVRT30 / U =1225# This capacity is greater than the design capacity at that post / beam connection specified on the approved plans of U = 772 #. Therefore the hurricane strap anchor is an an acceptable replacement for the hurricane clip anchor. If you have any questions and or comments, pleas feel free to contact this office at 561.891.9277. Si erel Faulkner Eyo DZN - Principal AR 1498 NORTHBORO HISTORIC DISTRICT 527 39 TH STREET WEST PALM BEACH, FL. 33407 T: 561.891.9277 F: 561.248.2283 DZN ARCHITECTURE ENGINEERING CONSTRUCTION 29 January 2013 Building Inspector City of Miami Shores Building Department NE 2"d Avenue Miami Shores, Florida 33138 Re : GutterPergola 746 NE 94th Street Miami Shores, Florida33138 Dear Sir / Madam: Please be advised of the following: (1) The front / south facing framing member PT 4x12 Wood Beam as shown on the approved plans is not requiredas a structural component and can be eliminated from the design to achievea different aesthetic. (2) The replacement Nu -Vue hurricane strap anchor used in place of the Nu -Vue hurricane clip anchor due to conflict with the steel seat of the steel column is acceptable and adequate. If you have any questions and or comments, please feel free to contact our office at 561.891.9277. DZN Prim i;)al AR 1 -1488 NORTHBORO HISTORIC DISTRICT 527 39TH STREET WEST PALM BEACH, FL. 33407 T: 561.891.9277 F: 561.827.8157 DZN ARCHITECTURE ENGINEERING CONSTRUCTION 15 January 2013 Building Inspector City of Miami Shores Building Department NE 2nd Avenue Miami Shores, Florida 33138 Re : GutterPergola 746 NE 94 Street Miami Shores, Florida33138 Dear Sir / Madam: Please be advised of the following: (1) The Hurricane anchor designated as USPRT15 is acceptable as an approved Hurricane anchor to replace the Nu -Vue anchors on the approved plans. (2) The notched rafter / beam design is acceptable for 3 " -4" notched application. If you have any questions and or comments, please feel free to contact our office at 561.891. • 277. Si DZN Principal AR 1498 NORTHBORO HISTORIC DISTRICT 527 39 TH STREET WEST PALM BEACH, FL. 33407 T: 561.891.9277 F: 561.827.8157 1 DZN ARCHITECTURE ENGINEERING CONSTRUCTION 15 January 2013 Building Inspector City of Miami Shores Building Department NE 2 1'd Avenue Miami Shores, Florida 33138 Re : GutterPergola 746 NE 9itin Street Miami Shores, Florida33138 Dear Sir / Madam: Please be advised of the following: (1) The Hurricane anchor designated as USPRT15 is acceptable as an approved Hurricane anchor to replace the Nu -Vue anchors on the approved plans. (2) The notched rafter / beam design is acceptable for 3 " -4" notched application. If you have any questions and or comments, please feel free to contact our office at 561.891.9277. Sinc F Principal AR 14988 NORTHBORO HISTORIC DISTRICT 527 39TH STREET WEST PALM BEACH, FL. 33407 T: 561.891.9277 F: 561.827.8157