Loading...
WS-13-223Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 185238 Permit Number: WS -2 -13 -223 Scheduled Inspection Date: February 19, 2013 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Gamer Building Miami Shores, FL 33138 -0000 Project <NONE> Contractor: CC DOOR CORP Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Door Replacement Phone Number Parcel Number 1121360010160 -22 Phone: (754)234 -7543 Building Department Comments REPLACE FRAME AND 2 DOORS Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed AJ:93.9 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. February 15, 2013 For Inspections please call: (305)762 -4949 Page 18 of 32 Miami Shores Village Building Department 90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 *BUII,D�IlNG PERMIT APPLICATION FEB 0 6 2013 FBC 201D Permit No. Master Permit No. W 5 I 3- Permit Type: (BUILDING) ROOFING JOB ADDRESS: 6-ec r ft e ( i-k 1 I 19 'c' We" god Ave City: Miami Shores County: Miami Dade Zip: 3-3 (G 1 Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): & 01 v" V t 1 i V P° d'5/ %�Y Phone#: ' ' der Address: I (3 3600 t) A to d Ave f City: AA 4t (41 i 6 4p�'L° State: Fie, ib V' Q Cl' e? Zip: 3'.9(4,1 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: (7- ( Y I 1P r �1 r Phone #: iel',� 1-759 3 Address: 5.3 67 0 1,44° 3 f Skr/'e- Re ea ' I / 6 City: 6a (/T l°�j p State: Ft c'r (dc/ Qualifier Name: C I, r( C_.. _ ' '% State Certification or Registration #: Certificate of Competency #: �8S 0'1 / Contact Phone#: 291- g3 i - 7 9#3 Email Address: ee'r eant 'iGc2 s t el Z' / DESIGNER: A r c h i t e c t / E n g i n e e r : frterri t i e ( _Syrtei `® 1751C-; A1106. t ■Ci Phone#: g6{°44 j-6 Zip: 33%4f Phone#: 2�/ z3� 7� 3 J Value of Work for this Permit: $�, Square/Linear Footage of Work: Type of Work: Addition !Alteration Description of Work: r e J!Q e -� Mt e Cf Viet d ee 1''s Pei ; t") ❑New kepair/Replace ❑Demolition Color thru tile: **a ********* **** ******v ****** **** ******Fees******** ***** ** **** ************************* Submittal Fee $5-6 �0 Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.FCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approv . and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this e> day of 341U41/ , 20 13 , by It G ErA whe is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Ex Contractor The foregoin instrument was acknowledged before me this -5 day of 2013, byrvy who is personally known to me or who has produced rt.-4 as identification and who did take an oath. ,�� tt111uN►rNo, Sign: Print: NOTARY PUBLIC: My Commission Expires: ::e 4 =o = Z ******************************* *** * ******** * ********* ***** **axe **** x****************** *** ** * ********* ******** APPROVED BY \ o 3 . Plans Examiner Structural Review (Revised 3 ///2012)(U €vised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk 111111111111111 1 11111111111 11111 11111 11111111 NOTICE OF COMMENCEMENT cFN 201380106391 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTIONORRBkO28481OPsri2018; (12si9 <s.3 HARVEY RUVIth CLERK OF COURT MIAMI-DADE COUI4TYs FLORIDA LAST PAGE PERMIT NON4/5-40 I3`" 3 TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Leg description of pr pe and street / address: , �.. a. rki i �'q � N' 13®67 � on S1-IOrrS, F iff W) � GLf''� ► 3316 2. Description of improve ent: s) name and address: Interest in property: Name and address of fee simple titleholder. 4. Contractor's Dame and address: wt-5/- 1149'e- eccrei 3331 n 5. Surety: (Paymn t bond requir�d�by owner from contractor, if any) Name and Address: V //�Pr Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: • 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration date of this Notice of Commencement: different date is s•ecified) the git rip date . of HEREBY CERTIFY that thtslsa true copy ate of odg1 ft4 filed 1: tf Al r ` A D 20�-- VI 1TNESS rrWW Signature of Owner HARVEY Print Owner's Name fekirrets ®tae Sworn to and subscribed before me this day of Marty , 20 Address: and and Official S less a Notary Public: Print Notary's Name: My commission expire BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Quality Engineered Products, Co., Inc. 4506 Quality Lane Tampa, FL 33622 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Series "IIMF" 16 ga Outswing Full Louvered Commercial Steel Door- Impact APPROVAL DOCUMENT: Drawing No. QEP005, titled "Full Louvered Steel Doors ", sheets 1 through 5 of 5, prepared by manufacturer, dated Nov 12, 2009, signed and sealed by David M. Schonacher, P. E. , bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division, MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitation: 1. Not approved where Air & Water infiltration is needed LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews # 04- 0823.03, consists of this page, evidence sheet E -1, as well as, approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.miamidade.gov/buildingcode MIAMI•DAD0 COUNTY APPROVED NOA No 09 -0812.17 Expiration Date: October 28, 2014 Approval Date: December 23, 2009 Page 1 I NO EXCEPTIONS TAKEN 0 MAKE CORRECTIONS NOTED 0 REVISE AND RESUBMIT ❑ REJECTED Review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Any action shown is subject to the requirements of the plans and cifications. Contractor is responsible for: Dimensions h ch shall be confirmed and correlated at the job site; tbrication processes and techniques of construction; c orlination rk with that of all other trades and the s *tis actory peitor ancq f tyrk. , . LQVXSi�d SObIATES, LLC Quality Engineered Products, Co., Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS (transferred from file # 04- 0823.03) 1. Manufacturer's die drawings and sections. 2. Drawing No. QEP005, titled "Full Louvered Steel Doors ", sheets 1 through 5 of 5, prepared by manufacturer, dated Nov 12, 2009, signed and sealed by David M. Schonacher, P. E. B. TESTS (transferred from file # 04- 0823.03) 1. Test reports on 1) Air Infiltration Test, per FBC TAS 202 -94 (Not Performed) 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202. 3) Water Resistance Test per FBC TAS 202 -94 (Not Performed). 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC and TAS 202 -94 Along with marked -up drawings and installation diagram of double Outswing full louvered Commercial Steel Doors, prepared by Certified Testing Laboratories Inc., Test Report No. CTLA 1255 -W -R, w/ revision dated September 14, 2004 (original test report dated July 28, 2004), signed and sealed by Ramesh Patel, P. E C. CALCULATIONS 1. Anchor verification calculations, dated 10/25/2005, prepared, signed and sealed by David M. Schonacher, P.E. D. QUALITY ASSURANCE BY: 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS (transferred from file # 04- 0823.03) 1. Tensile test report prepared by Certified Testing Laboratories Inc., Test Report No. CTL 1023J (CTLA114W), tested per ASTM E- A370 -97, dated December 02,2003, signed and sealed by Ramesh Patel, P. E. 2. Notice of Acceptance No. 07- 1107.08 issued to Dyplast Product, LLC (Former Apache Products Company) for `BPS- Expanded Polystyrene Insulation ", expiring on 01/11/12. F, STATEMENTS 1. Statesman letter of conformance to FBC 2007 and "No financial interest ", dated 12 -01 -2009, signed and sealed by David M. Schonacher, P. E. 2. Statement letter of compliance, as a part of the above referenced test report, issued by Certified Testing Laboratories Inc. G. OTHER 1. This NOA revises & renews # 04- 0823.03, expired on Oct 28, 2009 \ t 1.4,1 , Ishaq I. Chanda, P.E. Product Control Examiner NOA No 09- 0812.17 Expiration Date: October 28, 2014 Approval Date: December 23, 2009 E -1 INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 4. FOR INSTALLATION INTO WOOD FRAMING USE 3/8 INCH DIAMETER WOOD LAG SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 2 1/2 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. WOOD LAG SCREWS TO BE USED IN 3/4 INCH EMT PIPE SLEEVE. 5 FOR INSTALLATION THROUGH iX BUCK TO CONCRETE /MASONRY, OR DIRECTLY INTO CONCRETE /MASONRY, USE 3/8 INCH DIAMETER DYNABOLT SLEEVE ANCHOR BY ITW /REDHEAD OF SUFFICIENT LENGTH TO ACHIEVE 2 3/8 INCH MINIMUM EMBEDMENT. 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, ANO SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 10. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55. 0. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C -90, GRADE N, TYPE 1 (OR GREATER). QUALITY ENGINEERED PRODUCTS FULL LOUVERED COMMERCIAL STEEL DOOR GENERAL NOTES: 1. THE PRODUC7SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 2007 FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201- 94 /TAS 202 -94 (STRUCTURAL ONLY)/TAS 203 -94 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE /MASONRY AND 21 FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. (2) 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION 15 THE RESPONSIBIUTY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. S. THIS PRODUCT IS LARGE AND SMALL MISSILE IMPACT RESISTANT APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. DOOR FRAME MATERIAL: 16 GA. STEEL 7. STRUCTURAL MEMBER AT DOOR HEADER MUST BE DESIGNED TO CARRY 1796/FT LOAD AN D TO BE REVIEWED BY BUILDING OFFICIAL (OUTSWING) TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - INSTALLATION & GENERAL NOTES 2 - ELEVATIONS & DETAILS 3 - ANCHOR LAYOUTS 4 - VERTICAL SECTIONS & DETAILS 5 - HORIZONTAL SECTION, BILL OF MATERIALS, & DETAILS DESIGN PRESSURE RATING (OUTSWING DOORS WITH LOUVERS) WHERE AIR AND WATER FILTRATION REQUIREMENT I5 NOT NEEDED WHERE AIR AND WATER FILTRATION REQUIREMENT IS NEEDED MISSILE IMPACT RATING POSITIVE +70.0 PSF NOT APPROVED LARGE AND SMALL IMPACT RATED NEGATIVE -70.0 PSF NOT APPROVED LARGE AND SMALL IMPACT RATED 6 Y6e , $nw 4506 QUALM' 0 TAMPA, Fl. 33634 P6: (8131885-1693 911: (813) 884 -2673 G D O O m m m w ^1 m w <LL am at 0 d 0' REVISIONS O 0 2 Of N C PRODUCT RENEWgg as complying whh Lhi "WMy Bolding Code Acceptance l7 J ai Oade D,t O T CO ? ][ co V) a u 2 DWG #: QEP005 SHEET: 1 OF 5 2.00" 1 30.50" 56.00" 5.00" 81.50" 100.00" MAX, UNIT WIDTH 96.00" MAX. (48.00' MAX. WIDTH PER LEAF) -•-- 2.00" 2.00" INACTIVE ACTIVE @ INTERIOR SIDE EXTERIOR ELEVATION 98.00" 96.00" MAX. MAX. UNIT PANEL HEIGHT 1 HEIGHT 48.00" 38.00" 36.00" MAX. LOUVER WIDTH 9.00' 9.00" 9.00 9.00" 2.00" 98,00" MAX. 96.00" UNIT MAX. HEIGHT PANEL HEIGHT 52.00" MAX. UNIT WIDTH 48.00" MAX. WIDTH 80.00" MAX. LOUVER HEIGHT 6" O.C. 001 2.00' 2.00" 5.00 "1 f 4f 30.50" 56.00" 48.00" 1 38,00" ACTIVE 81.50" EXTERIOR ELEVATION (3) PIECES, EACH LOUVER,1 /2" SQUARE BAR STOCK FROM TAMPA STEEL & SUPPLY WELDED TO LOUVER FRAME AND TACK WELDED TO EACH LOUVER BLADE EACH LOUVER ATTACHED TO THE DOOR WITH (38) #6 X 1/2" SQUARE DRIVE SCREWS 14 - (LEFT) 14 - (RIGHT) 5 - (TOP) 5 - (BOTTOM) ILLUSTRATRED SEE DETAIL A INTERIOR VIEW LOUVER 1/2" SQUARE BAR STOCK WELD DETAIL A Snyclwwwl Pooduele, 160., 9no. 4506 QUALITY LN. TAMPA, FL, 33634 PH ;(613)685 -1693 F)1 (613)604 -2673 PREPARED BY: REVISIONS m DESCRIPTION O 2 ARODUCT RBNBWEio as i � LCodde 1Ml�eftlelLM Ateepaeallo° -a812.17 BYpraUoa Dal PrOdki DMeloa DWG #: QEP005 SHEET: 2 OF 5 100.00" MAX. UNIT WIDTH 8.00" MAX. FROM CORNERS TYP. 20.00" MAX. _ O.C. TYP. 8.00" MAX. FROM CORNERS; 11 TYP. • r.. TOTAL (5) ANCHORS AT EACH JAMB TOTAL (10) ANCHORS AT SILLS 98.00" MAX. UNIT HEIGHT 8.00" MAX. FROM CORNERS TYP. 8.00" MAX. FROM CORNERS TYP. II 1 1 1 1 1 1 t'� ANCHOR LOCATION INSTALLATION INTO MASONRY (GROUT FILLED BLOCKS) 52.00" MAX. —UNIT WIDTH —..._ 9.00" MAX. 0.C. TYP. 20.00" MAX. O.C. TYP. 8.00" MAX. [FROM CORNERS TYP, TOTAL (5) ANCHORS AT EACH JAMB TOTAL (5) ANCHORS AT SILLS 98.00" MAX. UNIT HEIGHT 8.00" MAX. FROM CORNERS I 9.00" MAX. TYP. O.L. TYP. ANCHOR LOCATION INSTALLATION INTO MASONRY (GROUT FILLED BLOCKS) 8.00" MAX. FROM CORNERS TYP. 9.00" MAX. O.C. TYP. 100.00" MAX. UNIT WIDTH 8.00" MAX. FROM CORNERS TYP. TOTAL (10) ANCHORS AT EACH JAMB TOTAL (10) ANCHORS AT SILLS 7. 98.00" MAX. UNIT HEIGHT f 8.00" MAX. FROM CORNERS TYP. 8.00" MAX. FROM CORNERS TYP. 9.00" MAX. O.C. TYP. 1 1 1 1 1 1 1 1 1 1 ANCHOR LOCATION INSTALLATION INTO WOOD STRUCTURE 52.00" MAX. UNIT WIDTH 9.00" MAX. 0.C. TYP. f 8.00" MAX. FROM CORNERS TYP. 1 TOTAL (10) ANCHORS AT EACH JAMB TOTAL (5) ANCHORS AT SILLS 98.00" MAX. UNIT HEIGHT t 8.00" MAX. I 1 1 900" MA FROM CORNERS I"-' TYP. ANCHOR LOCATION INSTALLATION INTO WOOD STRUCTURE Autekty S Y!e„ 9.w 4506 QUALITY LN. TAMPA. FL. 93634 PH: (813)485.1693 00 (813)894 -2679 w 1-- 1-O a 04 W 04 w 0 D REVISIONS 0 V w PRODUCT RENEWED u complying with the I lo.Mn Bolding Code Acaeplane,N -m Z•1% Rephntlon y M Dlvhion lU O :, C° 03 21) Zy a Y Q 1) V I- cyz DWG #: QEP005 SHEET: 3 OF 5 #6 5.M.5. 16 GA. STEEL 6" O.C. LOUVER RAID NO ANCHORS REQUIRED IN THE HEAD OF THE FRAME (SEE NOTE *) 1 1 1/4" EXT. I #6 S.M.5. 6" O.C. 18 GAUGE STEEL TOP CAP TACK WELD AND CAULK 4 13/16" SEE DETAIL B INTERIOR LOUVER, SEE DETAIL SHEET 2 16 GAUGE STEEL FULL WIDTH TOP CHANNEL SPOT WELD 4" O.C. 16 GAUGE CLOSER REINFORCEMENT TACK WELD TO CHANNEL EXTERIOR SEE DETAIL C SEE DETAIL D \ 4 (4)16 GAUGE CHANNELS CENTER REINFORCEMENTS AROUND LOUVER DOOR (4) 16 GAUGE FULL WIDTH BOTTOM CHANNEL SPOT WELD 4" ON CENTER SEE ELEVATION FOR ANCHOR SPACING 11 11/4" MIN. EMBEDMENT DETAIL B 16 GA. LOUVER COVER 16 GA. STEEL CUT CHANNEL 16 GAUGE STEEL FRAME SPOT WELDS (3) HAGER HINGES 43/2°° x4Y2" 7 GA. STEEL HINGE PLATE SPOT WELDS 1 1/4" STEEL HINGE PLATE 7 GAUGE X 1 -1/4" X 10" d n' 3" MIN. *NOTE: STRUCTURAL MEMBER EDGE AT HEADER MUST DESIGN TO DISTANCE CARRY 179 # /FT LOAD AND MUST BE REVIEWED BY VERTICAL SECTION BUILOINGOFFICIAL CONCRETE /MASONRY T 47/" INACTIVE DOOR 0 \ t i ‘11/2.. EXT. I / / DETAIL C DEADBOLT STRIKE ATTACHED DIRECTLY TO CHANNEL WITH 8/32 X 1/2" SCREWS LOCK STRIKE ATTACHED DIRECTLY TO CHANNEL WITH 12/24 X 1/2" SCREWS LOCK/DEAD BOLT STRIKE PLATE REINFORCEMENT 16 GAUGE STEEL BOTTOM CHANNEL SPOT WELD 4" ON CENTER EXT. VINYL BULB SEAL / 16 GAUGE STEEL DOOR SPOT WELDS 2 1/4" DETAIL D (3) HAGER HINGES 4 1/2" x 4 1/2" 7 GA. STEEL HINGE PLATE SPOT WELDS 1 1/4" 2 1/4" DEADBOLT STRIKE ATTACHED DIRECTLY TO CHANNEL WITH 8/32 X 1/2" SCREWS LOCK LATCH ATTACHED DIRECTLY TO CHANNEL WITH 8/32 X 1/2" SCREWS STEEL HINGE PLATE ACTIVE DOOR 7 GAUGE X 1 -1/4" X 10" LOCK/DEAD BOLT REINFORCEMENT 4506 QUALITY L51. TAMPA, FL. 33634 PH. (B13) 887.1693 F %:(813)889 -2673 REVISIONS O Ow 0 S Q PRODUCT RENEW as Balding Code a the Ne Acceptance Noa —B t. Enphrnon Dm y 871 1 ti�- Dt3Mion _ ea 0 tO 2 DWG #: QEP005 SHEET: it OF 5 Lf IVES 360 SURFACE BOLT 3" MIN. EDGE DISTANCE 3000 PSI MIN. GROUT 0 SEE DETAIL SHEET 4 17/8" MIN. EMBEDMENT m STEEL HINGE REINFORCEMNT 7 GA. X 1 i" X 10 WITH (4) #12 SMS HINGE SCREWS CD 5B HORIZONTAL SECTION JAMB - CONCRETE /MASONRY 15/8" 1/2" ) 1/4 T �Y- 5" PEMKO 2005AV THRESHOLD WITH VINYL SEAL BBL OF MAIEIOALS MARK QUANTITY DESCRIPTION 1 1 16 GA. (.083) MIN. STEEL HOLLOW METAL FRAME 1 SEE ELEV. 3M" 119' WOOD LAG SCREWS WI Sir EMT PIPE SLEEVE 7 2 10 GA. (.0836) MIN. STEEL HOLLOW METAL DOORS W/ LOWERS Fy M114. - 41,200 P81/FU MIN. ■ 57,800 PSO 4 0 RANGER HINGES 6131218 4-117' z 4A /2' z .13418100 5 2 IVES 380 SURFACE BOLTS 6 6 114" 6 3" STAINLESS STEEL FLAT HEAD BOLTANASHER/NUTS 7 1 1111E811010 PEMKO 62005ev INSTALLED 001010 WOOD SCREWS OR 3/16' 11W TAPCONS (SEE ELEV, PER SHEETS) 8 1 SCHLAOE AL53P010C31 W/ 8050 DEADLOCK B 1 RUSWINN C13355 LOCK W/ DL2113 DEADLOCK 10 1 MARKS 195A6 LOCK WI 1306 DEADLOCK 11 AS REQ. Ef6ANDED PDLYSTYRENE (809) BY APPACHE PRODUCTS (CURRENT RDA) 12 SEE ELEV. UP OM. DYNABOLT 11 WIREDHEAD SLEEVE A)(C OR (3)6' DIA.9011) X4 -112' SLEEVE ANCHOR 0/34" DIA. WELDED PIPE SLEEVE W /1 -7/e' MIN. EMBEDMENT6 3' MN. EDGE DISTANCE 13 AS REQ. 16 GA CUT OUT CHANNEL 14 AS REQ, 16 GA. LOUVER RAIL 15 AS REQ, 18 GA. LOWER BLADE 16 AS REQ. 16-0A. LOWER COVER INTERIOR ACTIVE EXTERIOR m (2) 2" X 6" WOOD BLOCKING "Ai isobuovisit H/3 /9" EMrf 2 1/2" MIN. EDGE DISTANCE 12 GA. STEEL BOX CHANNEL 1 1/2" X 41/2" FULL HEIGHT OF DOOR LOCKS AND LATCHES ATTACHED DIRECTLY TO CHANNEL HORIZONTAL SECTION ASTRAGAL 2 -3/8" PIPE WELDED TO BACKSIDE OF HOLLOW METAL FRAME 5 3/4" 2" 5/8" 115/16" I 1 115/16" f 17/8" h 16 GA. (.063 MIN.) STEEL FRAME PROFILE F3/8" 2 1/2" MIN. EMBEDMENT STEEL HINGE REINFORCEMNT 7 GA. X1i "X10WITH (4) #12 SMS HINGE SCREWS HORIZONTAL SECTION JAMB -2X WOOD FRAME 3/8" 1 1/4" -1 I~ 1 5/8" 3/8" r 11/2" 14 3/8" 2 5/8" 11/2" j-•—••-1 16 md..cld (.,, 9,w 4506 QUALITY LN. TAMPA, PL. 33634 PH: (519)663 -4693 FX: (813)884 -2673 PREPARED BY: O • � sr co Rn r; 6 1-4 W 1+f M xx W.( LL w • F 01 REVISIONS 0 m DESCRIPTION PRODUCT RENEWED o complying with Ru Rlo,Wi 8I4dIng Code Aec6pinnp No • �/ EapinUog I36 f/ M4q , l,.w Dhielen QEP005 SHEET: 5 OF 5