MC-11-1283 (2)Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 CL CC- 11- 5 ho Inspection Number: INSP - 173308 Permit Number: MC -7 -11 -1283 Scheduled Inspection Date: June 25, 2012 Inspector: Perez, JanPierre Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue NEW DOORM Miami Shores, FL 33138 -0000 Project: BARRY UNIVERSITY Contractor: HILL YORK SERVICE CORP Permit Type: Mechanical - Commercial Inspection Type: Final Work Classification: New Phone Number Parcel Number 1121360010160 -37 Phone: (305)756 -6501 Building Department Comments 2 AIR COOLED CHILLERS, UNDERVENT PIPING, CHILLED WATER PIPING IN BUILDING WITH CVHILLED WATER (*FCU), OUTSIDE AIR UNITS, EXHAUST WITH DUCT WORK l'Z Passed ►%J Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments T &B REPORT OK STILL MISSING KITCHEN HOO REINSPECTION FOR INSP- 162095. need T &B rep CALL JASON AT 954 -668 -9743 JPP CREATED AS rt and kitchen hood jpp June 22, 2012 For Inspections please call: (305)762 -4949 Page 13 of 43 CERTIFIED TEST & BALANCE CC II -5S0 CERTIFIED TEST, ADJUST AND BALANCE REPORT DATE: 06 /12/12 PROJECT: BARRY UNIVERSITY RESIDENCE HALL LOCATION: 11300 NE 2" AVENUE, MIAMI SHORES, FLORIDA 33161 NM URI ,d C APPROVED OROS O REVISE & MON O FOND o a TO 1101101041, EMU OF ARCM '1 ECT: CANNON - DESIGN DESIGN ENGINEER: E D S A GENERAL CONTRACTOR: MOSS AND ASSOCIATES, INC. MECHANICAL CONTRACTOR: HILL YORK SERVICE CORPORATION NEBB TAB CONTRACTOR: CERTIFIED TEST & BALANCE, INC. 2499 GLADES RROAD, SUITE 106A BOCA RATON, FLORIDA 33431 DENNIS T. MIRANDA, PRESIDENT CERTIFICATION NUMBER: 3064 (561) 961 -5068- OFFICE (561) 961 -5069 -FAX 0113 CERTIFIED TEST.& BALANCE PROJECT: BARRY UNIVERSITY RESIDENCE HALL LOCATION: 11300 NE 2N0 AVENUE, MIAMI SHORES, FLORIDA 33161 THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEEB TOLERANCES, ARE NOTED IN THE TEST- ADJUST - BALANCE REPORT PROJECT SUMMARY. NEBB CONTRACTOR: CERTIFIED TEST & BALANCE, INC. REG. NO: NEBB 3064 CERTIFIED BY: iii DATE: 06 /12/12 SUBMLTIED & CERT'D1ED BY: BROWARD CO. NO.: 98 -CTB -833 -W NEBB CONTRACTOR: CERTIFIED TEST & BALANCE, INC. TAB SUPERVISOR: DENNIS T. MIRANDA REG. NO.: NEBB 3064 DATE: 06 /12/12 GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 05/22/12 Page: 1 SYSTEM 1 RTU -1 RTU -2 LOCATION I ROOF ROOF AREA SERVED OUTSIDE AIR NORTH E OUTSIDE AIR SOUTH MANUFACTURER TRANE TRANE MODELNUMBER TCH301E300AB TCH301E300AB SERIAL NUMBER 1 113210877D 113210985D FAN DATA DESIGN u i : I: NI DESIGN MEASURED TOTAL CFM * OUTLET 3240 3276 3050 3194 OUTSIDE AIR CFM 3240 3276 3050 3194 S.P. TTL / EXT 1.5 .76 1.5 .90 INLET / DISCHARGE NS .35/.41 NS .411.49 FAN RPM NS NA NS NA MOTOR DATA DESIGN u i : 1: DESIGN u i 9.f. 1: MOTOR HP / HZ I 7.5 7.5 7.5 7.5 VOLTAGE / PHASE 208/3 207/208/206 208/3 207/206/208 AMPERAGE / SF 18.6 5.6/6.2/5.7 j 18.6 5.4/5.8/5.9 MOTOR RPM 3475 NA 3475 NA MOTOR PULLEY 3 X 1 1/8 s 3 X 1 1/8 FAN PULLEY 19 X 1 3/16 19 X 13/16 BELTS / POSITION / C—C (1) B X 94 / FIXED (1)B X 96 / TOP OUTSIDE AIR DUCT SIZE 62 X 1812 62 X 18 Y2 Comments: Readings By: Craig Maurer, Bart Serino CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 05/22/12 Page: 2 SYSTEM RTU -3 LOCATION ROOF AREA SERVED OUTSIDE AIR CENTER MANUFACTURER TRANE MODEL NUMBER TCH301E300AD SERIAL NUMBER 113210931D FAN DATA DESIGN MEASURED 3725 3913 3725 3913 TOTAL CFM * OUTLET OUTSIDE AIR CFM S.P. 'ITL / EXT INLET / DISCHARGE FAN RPM DESIGN MEASURED 1.5 NS NS 1.27 .71/.56 NA MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM 7.5 208/3 18.6 3475 7.5 207/206/207 5.9/6.1/5.7 NA MOTOR PULLEY 3X11/8 FAN PULLEY 19 X 1 3/16 BELTS / POSITION / C-C (1) B X 94 / FIXED / NA OUTSIDE AIR DUCT SIZE 62 X 18 %2 Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 05/22/12 Page: 3 SYSTEM AHU- 1 - 1 AHU- 1 -2 LOCATION AREA SERVED MANUFACTURER MODFJ NUMBER SERIAL NUMBER FAN DATA CEILING 1ST FLOOR LOBBY ENVIRO TEC HPPO8 CEILING RECEPTION ENVIRO TEC HPPO8 NS NS DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM / EXT INLET / DISCHARGE FAN RPM 800 800 0 NS NS NS 803 803 0 NA NA HIGH 800 800 0 NS NS NS 738 738 0 NA NA HIGH MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP! HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM 208/1 1.6 NS 207 1.21 HIGH 208/1 1.6 NS 206 1.31 HIGH MOTOR PULLEY FAN PULLEY BELTS / POSITION / C-C OUTSIDE AIR DUCT SIZE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 05/22/12 Page: 4 SYSTEM AHU -1 -3 AHU -1-4 LOCATION CEILING CEILING AREA SERVED LAUNDRY 1ST FLOOR MAIL ROOM MANUFACTURER ENVIRO "1 'EC ENVIRO TEC MODEL NUMBER HPPO8 HPPO8 SERIAL NUMBER NS NS FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 900 763 800 833 RETURN AIR CFM 900 763 800 833 OUTSIDE AIR CFM 0 0 0 0 S.P. '11L / EXT NS NA NS NA INLET / DISCHARGE NS NA NS NA FAN RPM NS HIGH NS HIGH MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ I VOLTAGE / PHASE 208/1 206 208/1 206 AMPERAGE / SF 1.6 1.25 1.6 1.3 MOTOR RPM NS HIGH NS HIGH MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SUE NA NA Comments: Readings By: Craig Maurer, Bart Serino V GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 05/22/12 Page: 5 SYSTEM AHU-1-5 AHU-1-6 LOCATION AREA SERVED MANUFACTURER MODEL NUMBER CEILING MECH. RM. 1ST FLOOR OFFICE MULTI PURPOSE ENVIRO '1F,C ENVIRO TEC HPPO8 CDV SERIAL NUMBER NS NS r FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 600 570 1490 1474 RETURN AIR CFM OUTSIDE AIR CFM S.P. T11 / EXT INLET / DISCHARGE FAN RPM MOTOR DATA 560 40 NS NS NS 528 1290 1270 42 200 204 NA NS NA NA NS NA DESIGN LOW MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM IA 1A. NS DESIGN (2) i/4 HIGH MEASURED IA 208/1 207 208/1 206 1.6 .97 4.4 1.4/1.5 NS LOW NS HIGH MOTOR PULLEY DIRECT DRIVE FAN PULLEY DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE OUTSIDE AIR DUCT SIZE 6 X 6 DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE 10" ROUND Comments: Readings By: Craig Maurer, Bart Serino V CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/4/12 Page: 6 SYSTEM AHU-1-7 AHU-1-7A LOCATION CEILING CEILING AREA SERVED RETAIL SERVING MANUFACTURER ENVIRO TEC ENVIRO TEC MODEL NUMBER HPP16 I-IPP20 SERIAL NUMBER NS NS FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 1600 1653 1985 1868 RETURN AIR CFM 1400 1457 1985 1868 OUTSIDE AIR CFM 200 196 0 0 S.P. TTL / EXT NS NA NS NA INLET / DISCHARGE NS NA NS NA FAN RPM NS MOTOR HP / HZ (2) 'A MED NS (2) 1/4 (2) 1/4 HIGH (2) V4 VOLTAGE / PHASE 208/1 206 208/1 207 AMPERAGE / SF 4 1.18/1.10 4 1.21/1.19 MOTOR RPM NS MED NS HIGH MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE 10" ROUND 10" ROUND Comments: Readings By: Craig Maurer, Bart Serino an CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/4/12 Page: 7 SYSTEM AHU-1-7B AHU-1-8 LOCATION CEILING CEILING AREA SERVED DINING LOUNGE MANUFACTURER ENVIRO ENVIRO TEC MODEL NUMBER HPP12 HPPO8 SERIAL NUMBER NS NS r- FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM MOTOR PULLEY DESIGN MEASURED 1200 1000 200 NS NS NS 1174 964 210 NA NA HIGH DESIGN 600 540 60 NS NS NS MEASURED 615 550 65 NA NA MED (2) V4 208/1 2 NS (2) 1/4 206 .79/.71 MED 1/4 208/1 1.6 NS 1/4 206 .96 MED DIRECT DRIVE FAN PULLEY DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE OUTSIDE AIR DUCT SIZE 10" ROUND DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE 7 X 6 Comments: Readings By: Craig Maurer, Bart Serino CrB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/4/12 Page: 8 SYSTEM AHU-1-9 AHU-2-1 LOCATION CEILING CEILING AREA SERVED IsT FLOOR TELECOM SECURITY ELEV LOBBY MANUFACTURER ENVIRO '1EC ENVIRO TEC MODEL NUMBER HPPO8 HPPO8 SERIAL NUMBER NS NS FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 600 678 * 800 734 RETURN AIR CFM 600 678 800 734 OUTSIDE AIR CFM 0 0 0 0 S.F. 1 / EXT NS NA NS NA INLET / DISCHARGE NS NA NS NA FAN RPM NS MOTOR DATA DESIGN LOW NS MEASURED DESIGN HIGH MEASURED MOTOR HP / HZ 1/4 VOLTAGE / PHASE 208/1 206 208/1 207 AMPERAGE / SF 1.6 .97 1.6 1.31 MOTOR RPM NS LOW NS HIGH MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments:* Low speed. Readings By: Craig Maurer, Bart Serino as CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /4/12 Page: 9 SYSTEM AHU -2 -2 AHU -2 -3 LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER FAN DATA CEILING LOUNGE ENVIRO 'I'EC CEILING STUDY ROOM ENVIRO TEC HPPO8 NS TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. TTL / EXT INLET / DISCHARGE FAN RPM HPPO8 NS DESIGN MEASURED DESIGN 800 770 600 800 770 600 MEASURED 0 NS NS NS 0 NA NA HIGH 0 NS NS NS 575 575 0 NA NA LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ 1/4 1/4 1/4 1/4 VOLTAGE / PHASE 208/1 206 208/1 207 AMPERAGE / SF 1.6 1.26 1.6 .96 MOTOR RPM NS HIGH NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE ! DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /6/12 Page: 10 SYSTEM AHU -3 -1 AHU -3 -2 LOCATION AREA SERVED MANUFACTURER. MODEL NUMBER SERIAL NUMBER CEILING ELEVATOR LOBBY ENVIRO TEC HPP12 NS CEILING LOUNGE ENVIRO TEC HPP12 NS FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. Tit / EXT INLET / DISCHARGE FAN RPM DESIGN 1000 1000 0 NS NS NS MEASURED 1005 1005 0 NA NA HIGH DESIGN 1000 1000 0 NS NS NS MEASURED 994 994 0 NA NA HIGH MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ (2) 1/6 (2) 1/6 (2) 1/6 (2) 1/6 VOLTAGE / PHASE AMPERAGE / SF 208/1 206 208/1 206 2 .72/.75 2 .79/.74 MOTOR RPM MOTOR PULLEY FAN PULLEY NS HIGH DIRECT DRIVE DIRECT DRIVE NS HIGH DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C -C OUTSIDE AIR DUCT SIZE DIRECT DRIVE NA DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino 1 aB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /6/12 Page: 11 SYSTEM AHU -3 -3 LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER FAN DATA CEILING LAUNDRY ROOM ENVIRO '1 EC HPPO8 NS DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 600 572 RETURN AIR CFM 600 572 OUTSIDE AIR CFM 0 0 S.P. TTL / EXT NS NA INLET / DISCHARGE NS NA FAN RPM NS LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ 14 VOLTAGE / PHASE 208/1 208 AMPERAGE / SF 1.6 .97 MOTOR RPM NS LOW MOTOR PULLEY DIRECT DRIVE FAN PULLEY DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY r Date: 06 /7/12 Page: 12 SYSTEM LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER AHU -1.5 CLOSET 101 ENVIRO TECH CDV FCU110815 -04B AHU -1.5 CLOSET 102 ENVIRO TECH CDV FCU110815 -045 FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. 'I°1'L / EXT INLET / DISCHARGE FAN RPM DESIGN 575 MEASURED DESIGN MEASURED 651 575 0 NS NS NS 651 0 NA NA LOW 575 575 0 NS NS NS 605 605 0 NA NA LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ 1/,/60 '/,/60 1/,/60 W60 VOLTAGE / PHASE 208/1 207/1 208/1 207/1 AMPERAGE / SF 2.7 .97 2.2 .98 MOTOR RPM NS LOW NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino aB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /08/12 Page: 13 SYSTEM AHU -2.0 AHU -1.5 LOCATION CLOSET CLOSET AREA SERVED 103 104 MANUFACTURER ENVIRO "I 'EC ENVIRO 'I EC MODEL NUMBER CDV CDV SERIAL NUMBER FCU110815 -04B FCU110815 -045 FAN DATA TOTAL CFM * OUTLET DESIGN 800 MEASURED 845 DESIGN 475 MEASURED 595 RETURN AIR CFM OUTSIDE AIR CFM S.P. TTL / EXT INLET / DISCHARGE FAN RPM 800 0 NS NS NS 845 0 NA NA MED 475 0 NS NS NS 595 0 NA NA LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ '/,/60 '/,/60 1/4/60 '//60 VOLTAGE / PHASE 208/1 207/1 208/1 208/1 AMPERAGE / SF 2.2 1.2 2 .97 MOTOR RPM NS MED NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino crn CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/08/12 Page: 14 SYSTEM AHU-1.5 AHU-1.5 LOCATION CLOSET CLOSET AREA SERVED 105 107 MANUFACTURER ENVIRO 1EC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER FCU110815-04 FCU110815-04B FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 575 634 575 667 RETURN AIR CFM 575 634 575 667 OUTSIDE AIR CFM 0 0 0 S.P. TTL EXT NS NA NS NA INLET! DISCHARGE NS NA NS NA FAN RPM NS LOW NS LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ 1/4/60 1/4/60 1/4/60 1/4/60 VOLTAGE / PHASE 208/1 207/1 208/1 208/1 AMPERAGE / SF 2 .98 2.2 .98 MOTOR RPM NS LOW NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/08/12 Page: 15 SYSTEM LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER FAN DATA TOTAL CFM*FAN TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM MOTOR PULLEY FAN PULLEY BELTS / POSITION / C-C OUTSIDE AIR DUCT SIZE AHU-1.5 CLOSET 108 ENVIRO 1EC CDV FCU110815-05 DESIGN 575 575 575 0 NS NS NS DESIGN 1/4/60 208/1 2 NS MEASURED 648 648 648 0 NA NA LOW MEASURED 1/4/60 207/1 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA AHU-1.5 CLOSET 109 ENVIRO TEC CDV FCU110815-05 DESIGN 575 575 575 0 NS NS NS DESIGN 1/4/60 208/1 2 NS MEASURED 638 638 638 0 NA NA LOW MEASURED %/60 207/1 .97 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino _ ...........aB ... . CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /08/12 Page: 16 FAN NO AHU -1.5 AHU -1.5 AHU -1.5 LOCATION SERVING CLOSET CLOSET ROOM 110 ROOM 111 CLOSET ROOM 112 MODEL NO CDV CDV CDV SERIAL NO MFGR FCU 110815 -04D FCU 110815 -04B ENVIO 'TECH ENVIO TECH FCU110815 -04 ENVIO TECH FAN DATA DESIGN CFM RETURN AIR DESIGN MEASURED DESIGN MEASURED 575 644 575 653 575 644 575 653 DESIGN MEASURED 575 640 575 640 OUTSIDE AIR STATIC PRESSURE 0 0 NS NA 0 0 0 0 NS NA NS NA RPM FAN HP /HZ VOLTAGE NS LOW NS LOW '/4/60 '/4/60 '/4/60 'V4/60 208 207 208 207 NS LOW /60 '/4/60 208 207 PHASE 1 1 AMPERAGE / SF 2.2 .98 2.2 .97 2.2 .97 RPM MOTOR NS LOW NS LOW NS LOW MFR PULLEY DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE FAN PULLEY BELT / POSITION / C-C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer 0113 CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/08/12 Page: 17 FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY AHU -1.5 AHU -2.0 AHU -2 CLOSET CLOSET CLOSET ROOM 113 ROOM 114 ROOM 133 STAFF APT. CDV CDV CDV FCUI 10815 -04 FCUI 10815 -04 FCU110815 -04 ENVIO TECH ENVIO TECH ENVIO TECH DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED 575 626 800 869 750 835 575 626 800 869 750 835 0 0 0 0 0 0 NS NA NS NA NS NA NS LOW NS MED NS HIGH '/4/60 '/4/60 '/4/60 '/4/60 '/4/60 /60 208 208 208 207 208 207 1 1 2 .98 2 1.3 2 1.5 NS LOW NS MED. NS HIGH DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / POSITION / C-C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer 07'13 CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/05/12 Page: 18 SYSTEM AHU -1.5 AHU -1.5 LOCATION CLOSET CLOSET AREA SERVED ROOM 201 ROOM 202 MANUFACTURER ENVIRO I EC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER FCU110815 -04B FCU110815 -04B FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM DESIGN 575 575 OUTSIDE AIR CFM S.P. TTL / EXT INLET / DISCHARGE FAN RPM MOTOR DATA 0 NS NS NS DESIGN MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM 1/,/60 208/1 2.2 NS MEASURED DESIGN 657 575 657 575 0 0 NA NS NA NS LOW NS MEASURED DESIGN %/60 1/4/60 207/1 208/1 .98 2.2 LOW NS MEASURED 671 671 0 NA NA LOW MEASURED 1/4/60 207/1 .99 LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/05/12 Page: 19 SYSTEM AHU-2.0 RIGHT AHU-1.5 LOCATION CLOSET CLOSET AREA SERVED ROOM 203 ROOM 204 MANUFACTURER ENVIRO iEC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. I 1L / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM MOTOR PULLEY FCU110815-0413 DESIGN 800 800 0 NS NS NS DESIGN 1/4/60 208/1 2.2 NS MEASURED 790 790 0 NA NA MED. MEASURED Y4/60 207/1 1.5 MED. DIRECT DRIVE FCU110815-04B DESIGN 475 475 0 NS NS NS DESIGN W60 208/1 2.2 NS FAN PULLEY DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA MEASURED 658 658 0 NA NA LOW MEASURED 1/4/60 204/1 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/05/12 Page: 20 SYSTEM AHU-1.5 LEFT LOCATION AREA SERVED MANUFACTURER AHU-1.5 RIGHT CLOSET CLOSET ROOM 205 ROOM 207 ENVIRO ..1EC ENVIRO 1'EC MODEL NUMBER CDV CDV SERIAL NUMBER FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. 1'1L / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM MOTOR PULLEY FAN PULLEY BELTS / POSITION / C-C OUTSIDE AIR DUCT SIZE FCU110815-04 FCUI10815-04B DESIGN MEASURED DESIGN MEASURED 575 601 575 642 575 0 601 0 NS NS NS NA NA LOW 575 0 NS 642 0 NA NS NA DESIGN MEASURED NS LOW DESIGN MEASURED W60 208/1 2.2 NS 1/4/60 207/1 .98 LOW 1/4/60 208/1 2.2 NS 1/4/60 207/1 .97 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/05/12 Page: 21 SYSTEM AHU-1.5 LEFT LOCATION AREA SERVED MANUFACTURER AHU-I .5 LEFT CLOSET ROOM 208 ENVIRO TEC CLOSET ROOM 209 ENVIRO TEC MODEL NUMBER SERIAL NUMBER CDV FCU110815-B4 CDV FCU110815-B4 FAN DATA DESIGN MEASURED DESIGN TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. TTL / EXT INLET / DISCHARGE FAN RPM 575 575 0 NS NS NS 642 642 0 NA NA LOW 575 575 0 NS NS NS MEASURED 633 633 0 NA NA LOW MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM DESIGN MEASURED DESIGN MEASURED 1/4/60 1/4/60 V4/60 208/1 207/1 208/1 2.2 .97 2.2 NS LOW NS 1/4/60 208/1 .99 LOW MOTOR PULLEY FAN PULLEY BELTS / POSITION / C-C OUTSIDE AIR DUCT SIZE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino an CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /05/12 Page: 22 SYSTEM AHU -1.5 RIGHT AHU -1.5 RIGHT LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER CLOSET ROOM 210 ENVIRO TEC CDV FCU110815 -04B CLOSET ROOM 211 ENVIRO TEC CDV FCU110815 -04B FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 575 684 575 673 RETURN AIR CFM OUTSIDE AIR CFM S.P. TTL / EXT INLET / DISCHARGE FAN RPM 575 0 NS NS NS 684 0 NA NA LOW 575 0 NS NS NS 673 0 NA NA LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ %/60 '/,/60 '//60 '/,/60 VOLTAGE / PHASE 208/1 207/1 208/1 207/1 AMPERAGE / SF MOTOR RPM MOTOR PULLEY FAN PULLEY BELTS / POSITION / C -C OUTSIDE AIR DUCT SIZE 2.2 NS DIRECT DRIVE .98 2.2 .97 LOW NS LOW DIRECT DRIVE DIRECT DRIVE NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino an CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /06/12 Page: 23 FAN NO AHU -1.5 LEFT AHU -1.5 LEFT AHU -2.0 LEFT LOCATION CLOSET CLOSET CLOSET SERVING ROOM 212 ROOM 213 ROOM 214 MODEL NO CDV CDV CDV SERIAL NO FCU110815 -04 FCU110815 -04 FCUI 10813 -04 MFGR ENVIRO TECH ENVIRO TECH ENVIRO TECH FAN DATA DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED DESIGN CFM 575 637 575 644 800 885 RETURN AIR 575 637 575 644 800 885 OUTSIDE AIR 0 0 0 0 0 0 STATIC PRESSURE NS NA NS NA NS NA RPM FAN NS LOW NS LOW NS MED. HP /HZ '/4/60 '/4/60 '/4/60 '/4/60 '/4/60 '//60 VOLTAGE 208 207 208 205 208 206 PHASE 1 1 1 1 1 1 AMPERAGE / SF 2 .98 2 .97 2 13 RPM MOTOR NS LOW NS LOW NS MED. MTR PULLEY DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / POSITION / C-C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer aB CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/06/12 Page: 24 FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY AHU -L5 LEFT AHU -1.5 RIGHT AHU -2.0 LEFT CLOSET CLOSET CLOSET ROOM 231 ROOM 232 ROOM 233 CDV CDV CDV FCU110815 -04 FCU110815 -04 FCU110815 -04 ENVIO 1'EC ENVIO TEC ENVIO 'lEC DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED 575 653 575 663 800 845 575 653 575 663 800 845 0 0 I 0 0 0 0 NS NA NS NA NS NA NS LOW NS LOW NS %4/60 1/4/60 1/4/60 1/4/60 '/4/60 208 207 208 208 208 1 1 1 1 1 2 .98 2 .97 2 MED. /60 205 1 1.3 NS LOW NS LOW DIRECT DRIVE DIRECT DRIVE NS MED. DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / POSITION / C -C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer CM CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/06/12 Page: 25 FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY AHU -1.5 LEFT AHU -1.5 AHU -1.5 CLOSET CLOSET CLOSET ROOM 234 ROOM 235 ROOM 237 CDV CDV CDV FCUI 10815 -04 FCUI 10815 -04 FCU110815 -04 ENVIRO TEC ENVIRO TEC ENVIRO TEC DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED 475 601 575 633 575 647 475 601 575 633 575 647 0 0 0 0 0 0 NS NA NS NA NS NA NS LOW NS LOW NS '/ / 60 1 /a /60 1//60 %4/60 %/60 208 207 208 207 208 1 2 1.0 2 .99 2 MED. 1A /60 207 1 1.1 NS LOW DIRECT DRIVE NS LOW DIRECT DRIVE NS MED. DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / POSITION / C -C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer GB CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/06/12 Page: 26 FAN NO AHU -1.5 AHU -1.5 AHU -1.5 LEFT LOCATION SERVING MODEL NO SERIAL NO CLOSET ROOM 238 CLOSET ROOM 239 CDV FCU110815 -04B CDV FCU110815 -04 CLOSET ROOM 240 CDV FCU110815 -04 MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN ENVIRO TEC DESIGN MEASURED 575 638 575 638 0 0 NS NA ENVIRO TEC ENVIRO 1EC DESIGN MEASURED DESIGN MEASURED 575 651 575 652 575 651 575 652 0 0 0 0 NS NA NS NA NS LOW NS LOW NS MED HP /HZ '/4/60 1/4/60 '/4/60 '/4/60 '/a /60 1//60 VOLTAGE PHASE 208 207 208 207 208 207 AMPERAGE / SF 2 1.0 2 RPM MOTOR NS LOW NS .99 LOW 2 NS 1.1 MED. MTR PULLEY DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE FAN PULLEY BELT / POSITION / C-C DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer cm CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 27 FAN NO AHU -1.5 AHU -1.5 AHU -1.5 LOCATION CLOSET CLOSET CLOSET SERVING ROOM 241 ROOM 242 ROOM 243 MODEL NO CDV CDV CDV SERIAL NO FCU 110815 -04 FCU110815 -04 FCU110815 -04 MFGR ENVIRO TEC ENVIRO TEC ENVIRO TEC FAN DATA DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED DESIGN CFM 575 649 575 657 575 648 RETURN AIR 575 649 575 657 575 648 OUTSIDE AIR 0 0 0 0 0 0 STATIC PRESSURE NS NA NS NA NS NA RPM FAN NS LOW NS LOW NS HP /HZ '/4/60 '/4/60 '//60 '/4/60 /60 VOLTAGE 208 207 208 208 208 PHASE 1 1 1 AMPERAGE / SF 2 .98 2 .97 2 LOW %4/60 207 1 .98 RPM MOTOR NS LOW MTR PULLEY DIRECT DRIVE NS LOW DIRECT DRIVE NS LOW DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / DIRECT DRIVE POSITION / C -C DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer crB CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 28 FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY AHU -2.0 AHU -1.5 AHU -1.5 CLOSET CLOSET CLOSET ROOM 244 ROOM 301 ROOM 302 CDV CDV CDV FCU110815 -04B FCU110815 -04 FCU110815 -04 ENVIRO TEC ENVIRO TEC ENVIRO TEC DESIGN MEASURED DESIGN MEASURED DESIGN MEASURED 800 885 575 648 575 637 800 885 575 648 575 637 0 0 0 0 0 0 NS NA NS NA NS NA NS MED. NS LOW NS LOW '/4/60 %4/60 '/4/60 '/4/60 '/4/60 '/4/60 208 207 208 207 208 207 1 1 2 1.3 2.2 .97 2.2 .98 NS MED NS LOW NS LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE POSITION / C -C Comments: Readings By: Bart Serino, Craig Maurer GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 29 SYSTEM AHU-2.0 AHU-1-5 LOCATION CLOSET CLOSET AREA SERVED ROOM 303 ROOM 304 MANUFACTURER ENVIRO TEC MODEL NUMBER CDV ENVIRO TEC CDV SERIAL NUMBER NS NS FAN DATA DESIGN TOTAL CFM * OUTLET 800 RETURN AIR CFM 800 MEASURED 830 830 DESIGN 475 475 MEASURED 589 589 OUTSIDE AIR CFM 0 0 0 0 S.P. 11L / EXT INLET / DISCHARGE NS NS NA NA NS NS NA NA FAN RPM NS MED. MOTOR DATA DESIGN MEASURED NS DESIGN LOW MEASURED MOTOR HP / HZ 1/4/60 1/4/60 '/4/60 1/4/60 VOLTAGE / PHASE AMPERAGE / SF 208/1 207 208/1 207 2.2 1.2 2.2 .97 MOTOR RPM NS MED. NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 30 SYSTEM AHU-1.5 AHU-1-5 LOCATION CLOSET CLOSET AREA SERVED ROOM 305 ROOM 307 MANUFACTURER ENVIRO 1EC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER --r FAN DATA DESIGN NS NS MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 575 634 575 643 RETURN AIR CFM 575 634 575 643 OUTSIDE AIR CFM 0 0 0 0 S.P. I 11, / EXT NS NA NS NA INLET / DISCHARGE NS NA NS NA FAN RPM NS LOW NS LOW MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ V4/60 1/4/60 1/4/60 1/4/60 VOLTAGE / PHASE 208/1 208 208/1 207 AMPERAGE / SF 2 .98 2.2 .97 MOTOR RPM NS LOW NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 31 SYSTEM AHU -1.5 AHU -1 -5 LOCATION CLOSET CLOSET AREA SERVED ROOM 308 ROOM 309 MANUFACTURER ENVIRO TEC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER NS NS FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P.TTL /EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ 575 637 575 637 0 NS 0 NA NS NS NA LOW DESIGN MEASURED 1/4/60 1/4/60 575 575 0 647 647 0 NS NS NA NA NS DESIGN 1/4/60 LOW MEASURED 1/4/60 VOLTAGE / PHASE 208/1 207 208/1 208 AMPERAGE / SF 2 .98 2 .99 MOTOR RPM NS LOW NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA Comments: Readings By: Craig Maurer, Bart Serino aB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06 /07/12 Page: 32 SYSTEM LOCATION AREA SERVED MANUFACTURER MODEL NUMBER SERIAL NUMBER FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. 1"1'L / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM MOTOR PULLEY AHU -1.5 AHU -1 -5 CLOSET CLOSET ROOM 310 ROOM 311 ENVIRO '1'EC ENVIRO TEC CDV CDV NS DESIGN 575 575 0 NS NS NS DESIGN 1/4/60 208/1 2.2 NS MEASURED 632 632 0 NA NA LOW MEASURED 1/4/60 208 .97 LOW DIRECT DRIVE NS DESIGN 575 575 0 NS MEASURED 643 643 0 NA NS NS DESIGN 1/4/60 208/1 2.2 NS FAN PULLEY DIRECT DRIVE BELTS / POSITION / C -C DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA NA LOW MEASURED %/60 207 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NA Comments: Readings By: Craig Maurer, Bart Serino a13 CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 33 SYSTEM AHU 1.5 AHU 1 5 LOCATION CLOSET CLOSET AREA SERVED ROOM 312 ROOM 313 MANUFACTURER ENVIRO TEC ENVIRO TEC MODEL NUMBER CDV CDV SERIAL NUMBER FAN DATA TOTAL CFM * OUTLET RETURN AIR CFM OUTSIDE AIR CFM S.P. TIL / EXT INLET / DISCHARGE FAN RPM MOTOR DATA MOTOR HP / HZ NS NS DESIGN 575 575 0 MEASURED DESIGN 659 659 0 NS NA NS NA NS LOW 575 575 0 NS NS NS DESIGN MEASURED DESIGN MEASURED 639 639 0 NA NA LOW MEASURED '/,/60 ' /a /60 '/4/60 '/./60 VOLTAGE / PHASE 208/1 207 208/1 208 AMPERAGE / SF 2 .98 2 .97 MOTOR RPM NS LOW NS LOW MOTOR PULLEY DIRECT DRIVE DIRECT DRIVE FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE DIRECT DRIVE OUTSIDE AIR DUCT SI7F NA NA Comments: Readings By: Craig Maurer, Bart Serino as CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 34 SYSTEM AHU -2.0 LOCATION CLOSET AREA SERVED ROOM 314 MANUFACTURER MODEL NUMBER ENVIRO TEC CDV SERIAL NUMBER NS FAN DATA DESIGN MEASURED DESIGN MEASURED 1 TOTAL CFM * OUTLET 800 835 RETURN AIR CFM 800 835 OUTSIDE AIR CFM 0 0 S.P. 't'IL / EXT INLET / DISCHARGE NS NS NA NA FAN RPM NS MED. MOTOR DATA DESIGN MEASURED DESIGN MEASURED MOTOR HP / HZ '/4/60 '/,/60 VOLTAGE / PHASE 208/1 207 AMPERAGE / SF 2 1.3 MOTOR RPM NS MED. MOTOR PULLEY FAN PULLEY DIRECT DRIVE DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA Comments: Readings By: Craig Maurer, Bart Serino GB CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR Date: 06/07/12 Page: 35 AHU -1.5 LEFT AHU -1.5 RIGHT AHU -2.0 LEFT CLOSET CLOSET CLOSET ROOM 331 ROOM 332 ROOM 333 CDV CDV CDV FCU110815 -04 FCU110815 -04B FCU110815 -04 ENVIRO TEC ENVIRO TEC ENVIRO TEC FAN DATA DESIGN DESIGN CFM 575 RETURN AIR 575 OUTSIDE AIR 0 STATIC NS PRESSURE RPM FAN NS HP /HZ '4/60 VOLTAGE 208 PHASE 1 AMPERAGE / SF 2 RPM MOTOR NS MTR PULLEY FAN PULLEY MEASURED DESIGN MEASURED DESIGN MEASURED 654 575 662 800 883 654 575 662 800 883 0 0 0 0 0 NA NS NA NS NA LOW NS LOW NS %4/60 %/60 '/4/60 '/4/60 207 208 208 208 .98 2 .97 2 BELT / POSITION / C-C Comments: LOW NS LOW NS MED. '/ / 60 207 1 1.2 MED. DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Readings By: Bart Serino, Craig Maurer DIRECT DRIVE DIRECT DRIVE GB CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 36 FAN NO LOCATION SERVING AHU -1.5 AHU -1.5 AHU -1.5 CLOSET CLOSET ROOM 334 ROOM 335 CLOSET ROOM 337 MODEL NO CDV CDV CDV SERIAL NO MFGR FCU110815 -04 FCU110815 -04B FCU110815 -04 FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE ENVIRO TEC ENVIRO TEC ENVIRO TEC DESIGN MEASURED DESIGN 4- MEASURED DESIGN MEASURED 475 989 575 475 989 575 0 0 0 NS NA NS 662 662 0 NA 575 575 0 NS 639 639 0 NA NS LOW NS LOW NS LOW 1/4/60 1/4/60 1/4/60 '/4/60 %4/60 1/4/60 208 207 208 208 208 207 PHASE 1 1 1 1 1 1 AMPERAGE / SF 2 .97 2 .98 2 .98 RPM MOTOR MTR PULLEY FAN PULLEY BELT / POSITION / C-C NS 1 LOW NS LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE NS LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Comments: Readings By: Bart Serino, Craig Maurer 07'13 CERTIFIED TEST & BALANCE Alit HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 37 FAN NO AHU -1.5 LOCATION CLOSET 1 AHU -1.5 AHU -1.5 CLOSET CLOSET SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY BELT / POSITION / C-C Comments: ROOM 338 ROOM 339 ROOM 340 CDV FCU110815 -04B ENVIRO TEC DESIGN MEASURED 575 575 0 NS NS 1/4/60 208 1 2.2 NS 674 674 0 NA LOW 1/4/60 207 1 .97 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Readings By: Bart Serino, Craig Maurer CDV FCU110815 -04B ENVIRO TEC DESIGN MEASURED 575 575 0 NS NS 1 /a /60 208 1 2.2 NS 653 653 0 NA LOW 1/4/60 208 1 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE CDV FCU1 10815 -04B ENVIRO TEC DESIGN MEASURED 575 575 0 NS NS 1/4/60 208 1 2.2 NS 659 659 0 NA LOW 1 /a /60 207 1 .97 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE an CERTIFIED TEST & BALANCE AIR HANDLER UNIT DATA SHEET Project: BARRY UNIVERSITY Date: 06/07/12 Page: 38 FAN NO AHU -1.5 AHU -1.5 AHU -1.5 LOCATION CLOSET CLOSET CLOSET SERVING ROOM 341 ROOM 342 ROOM 343 MODEL NO CDV CDV CDV SERIAL NO FCU110815 -04 FCU110815 -04 FCU110815 -04 MFGR FAN DATA DESIGN CFM RETURN AIR OUTSIDE AIR STATIC PRESSURE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY BELT / POSITION / C -C Comments: ENVIRO TEC DESIGN 575 575 0 NS NS '/4/60 208 1 2 NS MEASURED 647 647 0 NA LOW %4/60 207 1 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Readings By: Bart Serino, Craig Maurer ENVIRO TEC DESIGN 575 575 0 NS NS '/4/60 208 1 2 NS MEASURED 659 659 0 NA LOW '14/60 207 1 .97 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE ENVIRO TEC DESIGN 575 575 0 NS NS '/4/60 208 1 2 NS MEASURED 661 661 0 NA LOW '/4/60 207 1 .98 LOW DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE aB CERTIFIED TEST & BALANCE AIR HANDLING UNIT DATA SHEET Project: BARRY UNIVERSITY SYSTEM AHU -2 Date: 06/07/12 Page: 39 LOCATION CLOSET AREA SERVED ROOM 344 MANUFACTURER ENVIRO 'rEC MODEL NUMBER CDV SERIAL NUMBER FCU10815 -045 FAN DATA DESIGN MEASURED DESIGN MEASURED TOTAL CFM * OUTLET 800 809 RETURN AIR CFM 800 809 OUTSIDE AIR CFM S.P. TTL / EXT 0 NS 0 NA INLET / DISCHARGE NS NA FAN RPM NS MED. MOTOR DATA MOTOR HP / HZ VOLTAGE / PHASE AMPERAGE / SF MOTOR RPM DESIGN MEASURED DESIGN MEASURED '/60 %/60 208/1 2.2 NS 208 1.3 MED. MOTOR PULLEY DIRECT DRIVE FAN PULLEY DIRECT DRIVE BELTS / POSITION / C-C DIRECT DRIVE OUTSIDE AIR DUCT SIZE NA Comments: Readings By: Craig Maurer, Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY EXHAUST FAN DATA SHEET Date: 06N09/12 Page: 40 FAN NO LOCATION SERVING EF -2 EF -3 EF-4 CEILING CEILING CRII,ING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM S.P. SUCTION / DISCHARGE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY BELT / POSITION / C -C Comments: MEN VQ200 NS ACME DESIGN 150 NS NS NS NS 120 1 1.8 NS MEASURED 188 NA NA NA NA 122 1 1.1 NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Readings By: Craig Maurer WOMEN VQ200 NS ACME DESIGN 150 NS NS NS NS 120 1 1.8 NS MEASURED 175 NA NA NA NA 121 1 1.1 NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE CHILL PUMP ROOM VQ200 NS ACME DESIGN 200 NS NS NS NS 120 1 1.8 NS MEASURED 252 NA NA NA NA NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE cn3 CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY EXHAUST FAN DATA SHEET FAN NO EF -6 LOCATION SERVING MODEL NO SERIAL NO MFGR Date: 06/09/12 Page: 41 MAIN ELECTRIC FAN DATA VQ500 NS ACME DESIGN MEASURED ROOF TRASH CHUTE PDU100RFH 11J1745 -12 ACME DESIGN MEASURED DESIGN MEASURED DESIGN CFM S.P. SUCTION / DISCHARGE VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY BELT / POSITION / C -C Comments: Readings By: Craig Maurer DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY EXHAUST FAN DATA SHEET Date: 06/07/12 Page: 42 FAN NO LOCATION SERVING MODEL NO SERIAL NO MFGR FAN DATA DESIGN CFM S.P. SUCTION / DISCHARGE RPM FAN HP /HZ VOLTAGE PHASE AMPERAGE / SF RPM MOTOR MTR PULLEY FAN PULLEY EF -8 EF -9 CEILING CEILING TRASH ROOM ELEVATOR MECH. ROOM VQ500 VQ500 NS NS ACME ACME DESIGN 400 MEASURED DESIGN 451 400 MEASURED DESIGN MEASURED 424 NS NA NS NA NS NA NS NA NS NA NS NA NS NA NS NS 115 121 115 121 1 1 1 1 2.2 1.9 2.2 2.0 NS NA NS NA DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE BELT / DIRECT DRIVE 1 DIRECT DRIVE POSITION / C -C Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -1 AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 05/21/12 Page: 43 Floor: 3RD NORTH TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM CORR 1 CD 24 X 24 1.0 85 59 89 308 2 CD 6X6 1.0 60 133 66 309 3 CD 6X6 1.0 60 105 310 4 311 5 CD CD 6X6 1.0 60 120 64 62 6X6 1.0 60 130 65 312 6 CD 6X6 1.0 60 89 65 313 7 CD 6X6 1.0 60 81 64 CORR 8 CD 24 X 24 1.0 85 65 81 314 9 CD 6 X 6 1.0 60 96 62 306 10 SW 8 X 6 1.0 100 155 108 307 11 CD 6 X 6 1.0 60 94 65 320 12 SW 8 X 6 1.0 100 85 89 305 13 CD 6 X 6 1.0 60 120 60 CORR 14 CD 24 X 24 1.0 85 74 79 CORR 15 CD 24 X 24 1.0 STTL 85 1080 77 1603 STTL 84 1103 Comments: Readings By: Craig Maurer CTI3 CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -1 AREA SERVED AIR OUTLET DATA SHEET OUTLET NO. TYPE SIZE AREA CORR 208 209 210 211 212 213 CORR CORR 214 206 207 220 CORR 205 16 CD 6X6 1.0 DESIGN i FPM CFM 85 Date: 05/21/12 Page: 44 Floor: 2ND NORTH TEST CFM #1 #2 86 17 CD 6X6 1.0 60 132 18 CD 6X6 1.0 60 110 81 65 61 19 20 CD CD 6X6 1.0 60 139 64 6X6 1.0 60 166 21 CD 6X6 1.0 60 112 22 CD 6X6 1.0 60 125 23 CD 6X6 1.0 60 91 24 CD 6X6 1.0 85 87 25 26 CD SW 6X6 1.0 60 118 8X6 1.0 100 110 27 28 CD sw 6X6 1.0 60 101 8X6 1.0 100 115 29 CD 6X6 1.0 85 45 30 CD 6X6 1.0 60 81 S'1 "1'L 1080 1618 S1 1L 64 63 60 78 84 64 109 64 105 81 62 1105 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -1 AIR OUTLET DATA SHEET Date: 05/21/12 Page: 45 Floor: 1ST NORTH AREA SERVED OUTLET NO. TYPE SIZE AREA CORR 31 CD 24 X 24 1.0 108 32 CD 6X6 1.0 DESIGN TEST CFM MEASURED FPM CFM #1 #2 FPM CFM 85 71 60 123 111 35 CD 6X6 1.0 112 36 CD 6X6 113 37 CD 6X6 1.0 CORR 38 CD 24 X 24 1.0 114 39 CD 6 X 6 1.0 1.0 60 126 60 84 60 106 60 102 85 85 60 117 58 61 62 85 63 106 40 SW 7'/4 X 5'/4 .26 385 100 388/101 354 92 =11111111111111111n11 61111111M111111.11111111111111111111 120 42 SW 7'/4 X 5'A .26 385 100 312/94 CORR 43 CD 24 X 24 1.0 105 44 CD 6X6 1.0 369 96 85 54 79 60 11I 66 CORR 45 CD 24 X 24 1.0 85 59 77 STTL 1080 1446 STTL 1068 TOTAL 3240 TOTAL 3276 L Comments: Readings By: Craig Maurer am CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU-2 AIR OUTLET DATA SHEET Date: 05/21/12 Page: 46 Floor: 18T AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM STORE 1 CORR 2 CD 24X24 1.0 137 3 CD 12 X 12 1.0 136 4 AHU1 -8 5 DUCT 6 7 DUCT SW 8X6 1.0 50 284 53 85 149 91 100 CD 12 X 12 1.0 100 CORR AHU1 -5 7X6 .29 207 60 CD 24 X 24 1.0 85 6X6 .25 160 40 152 8 CORR 9 CD 24 X 24 1.0 300 186 188 259/75 96 109 108 224 65 89 104/26 168 42 218 278 CD 24 X 24 1.0 85 110 92 CORR 10 CD 24 X 24 1.0 85 96 90 STI'L 990 1612 S'1'1'L 1017 Comments: Readings By: Craig Maurer ......CTI3 ........ . CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -2 AIR OUTLET DATA SHEET Date: 05/21/12 Page: 47 Floor: 1ST AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE 237 11 248 12 CORR SIZE AREA FPM CFM #1 #2 SW 6X6 CD 71/4X51/4 13 SW 24 X 24 1.0 1.0 60 FPM CFM 153 64 .26 384 100 338/88 419 109 235 14 CD 6X6 1.0 CORR 15 CD 24 X 24 1.0 239 16 CD 6 X 6 1.0 238 17 CD 6 X 6 CORR 18 CD 24 X 24 241 19 CD 6X6 1.0 85 99 60 172 85 88 60 134 90 65 92 62 1.0 60 735 60 1.0 85 72 87 240 20 CD 6 X 6 1.0 60 99 236 25 CD 6X6 1.0 50 40 52 SI'I L 1030 1605 STTL 1092 Comments: Readings By: Craig Maurer CM CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -2 AREA SERVED AIR OUTLET DATA SHEET OUTLET NO. TYPE SIZE AREA 1 DESIGN Date: 05/21/12 Page: 48 Floor. 3RD TEST CFM MEASURED FPM CFM #1 #2 FPM CFM 337 336 348 CORR 335 339 338 341 CORR CORR 340 343 342 38 CORR 39 344 40 26 27 28 29 30 31 32 33 34 35 36 37 CD CD 6X6 1.0 60 104 24 X 24 1.0 50 90 SW CD CD CD CD CD CD CD CD CD CD CD CD 7'X5Ya 24 X 24 6X6 6X6 6X6 6X6 .26 1.0 1.0 1.0 1.0 1.0 100 85 60 566/147 60 60 60 68 93 408 125 135 115 24 X 24 1.0 85 63 24 X 24 6X6 6X6 6X6 24 X 24 6X6 1.0 1.0 1.0 1.0 1.0 1.0 S'ITL 85 60 60 60 85 60 1030 88 104 93 97 68 122 1512 STTL TOTAL 65 54 106 89 64 65 60 64 91 90 62 65 60 87 63 1085 3194 Comments: Readings By: Craig Maurer 1 aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU-3 AIR OUTLET DATA SHEET Date: 05/21/12 Page: 49 Floor: 1ST AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO, TYPE SIZE CORR 102 101 117 CORR 104 103 118 CORR CORR AHU1 -4 133 1 CD 24 X 24 AREA FPM 1.0 ICFM #1 I #2 FPM CFM 85 72 86 2 CD 6X6 1.0 60 81 64 3 4 CD CD 6X6 1.0 60 74 65 6X6 1.0 60 92 64 5 6 CD CD 24 X 24 1.0 85 66 6X6 1.0 60 81 7 CD 6X6 1.0 60 79 8 SW 71/4X5 1A .26 385 100 392/102 9 10 CD SW 24 X 24 1.0 85 69 24 X 24 1.0 85 65 11 DUCT 6 X 6 .25 200 50 220/55 220 12 SW 6X6 1.0 60 86 S1"1 'L 850 922 S'1'1L 79 61 58 107 79 77 55 63 858 Comments: Readings By: Craig Maurer (TB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTU -3 AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 05/21/12 Page: 50 Floor 2N TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM CORR 202 201 CORR 217 203 218 200 CORR 21 231 22 232 23 CORR 24 234 25 249 26 233 27 247 28 STAIR 29 13 14 15 16 17 18 19 20 CD 24 X 24 CD 6X6 CD 6X6 CD 24 X 24 62 85 89 63 85 64 62 82 SW 7 1/4X5 CD 6X6 427/111 101 SW 7'4X5'/4 CD 24 X 24 CD 24X24 CD 6X6 CD 6X6 473/123 63 1.0 1.0 85 60 59 400 104 65 392 102 70 81 104 64 1.0 60 132 CD 24 X 24 CD 6X6 1.0 1.0 85 60 68 112 SW 7'4X5'/4 CD 6X6 SW 7 1/4X5 SW 12X8 .26 1.0 .26 1.0 Comments: Readings By: Craig Maurer 100 60 404/105 100 107 352/92 200 STIL 1435 163 1489 65 78 63 408 106 62 400 104 184 STTL 1442 aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: O/A RTES.-3 AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 05/21/12 Page: 51 Floor: 3R' TEST CFM MEASURED NO, 1 TYPE SIZE 1 AREA 304 30 CD 6X6 1 1.0 FPM CFM #1 #2 FPM CFM 60 81 62 CORR 31 CD 24 X 24 1 1.0 85 0 84 302 301 CORR 32 33 34 CD 6X6 CD 6X6 1.0 60 84 60 1.0 60 82 65 CD 24 X 24 1 1.0 85 50 80 317 35 SW 71/4X5 'A 1 1.0 100 126 108 303 36 CD 24 X 24 1.0 60 69 65 318 37 SW 7 %X5'h 1.0 100 103 109 300 38 CD 24 X 24 1.0 75 53 70 332 39 CD 6X6 1.0 60 104 66 331 40 CD 6X6 1.0 60 85 62 CORR 41 CD 24 X 24 1.0 85 59 79 CORR 42 CD 24 X 24 1.0 85 53 77 334 43 CD 6X6 1.0 60 81 64 349 44 SW 7Y4X51/ 1.0 100 137 104 303 45 CD 24 X 24 1.0 60 33 62 347 46 SW 7'/X5Y4 .26 100 381/101 101 STAIR 47 CD 12X8 1.0 200 182 184 T STTL 1435 S'1 1'L 1502 TTL 3913 CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/05/12 Page: 52 Floor: 1 TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 AHU1 -1 LOBBY LOBBY STAIRW. 1 2 CD CD 24 X24 1.0 400 383 #2 FPM CFM 24X24 1.0 400 287 3 SW 12X8 1.0 100 166 TTL 900 836 ITL 355 348 100 803 AHU -1 -2 RECEPT. RECEPT. 1 CD 24 X 24 1.0 400 377 2 CD 24 X 24 1.0 400 361 TTL 800 738 11L 377 361 738 AHU1 -3 LAUNDR LAUNDR AHU1 -4 MAIL RM MAIL RM MAIL V. MAIL V. OFFICE OFFICE 1 CD 24 X 24 2 CD 24 X 24 1.0 450 341 1.0 450 436 11L 900 777 TTL 384 379 763 1 CD 24 X 24 1.0 150 162 2 CD 24 X 24 1.0 150 121 3 CD 24 X 24 1.0 150 147 4 CD 24 X 24 1.0 150 143 5 CD 24 X 24 1.0 100 102 6 CD 24 X 24 1.0 100 105 ITL 800 840 TTL 163 160 152 148 104 106 833 CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 53 Floor: 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE, AREA FPM CFM #1 #2 FPM CFM AHU1 -5 148 1 CD 24 X 24 1.0 150 194 148 148 2 CD 24 X 24 1.0 150 183 138 150 3 CD 149 4 CD 24 X 24 1.0 150 199 143 24 X 24 1.0 150 182 141 i IL 600 758 TTL 570 AHU1 -6 MULTI P. 1 CD 12 X 12 1.0 50 123 54 MULTI P. 2 CD 24 X 24 1.0 240 237 240 MULTI P. 3 CD 24 X 24 1.0 240 235 231 MULTI P. 4 CD 24 X 24 1.0 240 245 235 MULTI P. 5 CD 24 X 24 1.0 240 224 MULTI P. 7 CD 24 X 24 1.0 240 196 234 Tit 1490 1486 i'IL 1474 Comments: Readings By: Craig Maurer crs CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 05/24/12 Page: 54 Floor: 1 TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM AHU1 -7 C -STORE 1 CD 24 X 24 1.0 150 165 163 C -STORE 2 CD 24 X24 1.0 150 169 162 C -STORE 3 CD 24 X 24 1.0 200 173 190 C -STORE 4 CD 24 X 24 1.0 200 197 208 C -STORE 5 CD 24 X 24 1.0 200 170 196 C -STORE 6 CD 24 X 24 1.0 200 190 218 C -STORE C -STORE 7 8 CD CD 24 X 24 1.0 200 225 199 24 X 24 1.0 150 175 158 C -STORE 9 CD 24 X 24 1.0 150 200 159 11, 1600 1664 TTL 1653 AHU1 -7A SERV 1 CD 24 X 24 1.0 480 121 451 SERV 2 CD 24 X 24 1.0 480 149 447 SERV 3 CD 24 X 24 1.0 325 119 311 SERV 4 CD 24 X 24 1.0 325 90 304 SERV 5 CD 24 X 24 1.0 50 0 54 SERV 6 CD 24 X 24 1.0 325 80 301 TTL 1985 559 1"1'L 1868 Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: MU AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/05/12 Page: 55 Floor TEST CFM MEASURED NO. TYPE SIZE AREA #1 #2 FPM CFM AHU1 -7B SAND. SAND. SAND. SAND. SAND. SAND. 1 2 3 4 5 CD CD CD CD CD 24 X 24 24 X 24 24 X 24 24 X 24 24 X 24 1.0 1.0 1.0 1.0 1.0 6 CD 24 X 24 1.0 200 200 200 200 200 TTL 1200 175 189 201 173 204 215 1157 TTL 190 203 199 183 214 185 1174 Comments: Readings By: Craig Maurer .........au ........ CERTIFIED TEST & BALANCE Project: BARRY UN1VERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 56 Floor: l MEASURED FPM CFM 1 AHU1 -8 LOUNGE 1 CD 24 X 24 1.0 LOUNGE 2 CD 24 X 24 1.0 LOUNGE 3 CD 24 X 24 1.0 LOUNGE 4 CD 24 X 24 1.0 150 149 148 150 195 150 175 150 162 AHU1 -9 TELECOM 1 DUCT 19 X 12 �A 1.62 370 600 419/678 419 678 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA SERVED AIR OUTLET DATA SHEET OUTLET Date: 06/06/12 Page: 57 Floor: 2 DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM AHU2 -1 ELEV. L. ELEV.L. AHU2 -2 LOUNGE LOUNGE AHU2 -3 STUDY STUDY 1 2 CD 24 X 24 CD 24X24 1.0 400 370 1.0 400 364 f1'L 800 734 TTL 372 364 734 1 2 CD 24 X 24 CD 24X24 1.0 400 392 1.0 400 378 ITL 800 770 TTL 392 378 770 1 CD 24 X 24 1.0 300 348 2 CD 24 X 24 1.0 300 374 1'i'L 600 722 ITL 284 291 575 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 58 Floor: 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. AHU3 -1 ELEV. L. ELEV.L. AHU3 -2 LOUNGE LOUNGE AHU3 -3 STUDY STUDY 1 TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 1 2 CD 24X24 1.0 CD 24 X 24 1.0 TTL 500 500 1000 505 500 1005 TTL 505 500 1005 1 2 CD 24X24 1.0 CD 24 X 24 1.0 500 274 500 283 TTL 1000 557 '1'1L 502 492 994 1 CD 24 X 24 1.0 300 303 2 CD 24 X 24 1.0 300 260 TTL 600 563 TTL 291 281 572 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU -2, EXHAUST AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/08/12 Page: 59 Floor. 1 TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 133 KITCHEN LIVING R BED A 1 CD 12X6 1.0 100 84 90 2 3 CD CD 12X 12 12 X 12 1.0 1.0 BED B 4 CD 12 X 12 1.0 BED C 5 CD 6 X 6 1.0 BEDD 6 CD 6X6 1.0 250 150 340 169 150 125 50 89 315 177 TTL 750 877 151 52 50 TTL 835 EXHAUST BATH C 1 CD 10 X 10 1.0 75 83 BATH D 2 CD 10 X 10 1.0 75 75 Comments: Readings By: Bart Serino 3 CD 10X10 1.0 GB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/07/12 Page: 60 Floor: 1 OUTLET NO. TYPE SIZE DESIGN AREA FPM TEST CFM MEASURED CFM #1 #2 FPM CFM SW 12X8 1.0 RM 102 A TTL 250 226 254 75 102 96 575 622 'ITL 605 1 SW 12X8 1.0 250 340 322 B 2 SW 12X8 1.0 C 3 250 315 329 CD 10X10 1.0 75 0 0 IIL 575 655 I IL 651 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/08/12 Page: 61 Floor: 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 103 A 1 SW 2 SW C 3 SW D 4 SW 12X8 12X8 12X8 1.0 1.0 1.0 200 203 150 ns 150 206 200 188 100 65 800 877 E 5 CD 12X12 1.0 TTL 205 160 210 95 TTL 845 A B 1 SW 12X8 1.0 400 510 512 2 CD 6X6 1.0 75 120 83 TTL 475 630 1 "1'L 595 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AIM AIR OUTLET DATA SHEET Date: 06/08/12 Page: 62 Floor 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA RM 105 A B C FPM I CFM #1 #2 FPM CFM 1 SW 12X8 1.0 250 255 265 2 SW 12X8 1.0 250 285 3 CD 6X6 1.0 75 109 TTL 575 649 274 95 1'1'L 634 RM 107 A B C 1 SW 12X8 1.0 2 SW 12X8 1.0 3 CD 6X6 1.0 250 250 75 TTL 575 301 273 145 719 280 277 110 i°lL 667 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY AIR OUTLET DATA SHEET Date: 06/08/12 Page: 63 System: AHU Floor: 1 DESIGN TEST CFM MEASURED Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/08/12 Page: 64 Floor: 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 110 A 1 SW 12X8 1.0 250 B 2 SW 12X8 1.0 250 C 3 CD 6X6 1.0 75 TTL 575 280 140 710 1 "IL 279 95 644 RM 111 A B 1 SW 12X8 1.0 250 310 277 2 SW 12X8 1.0 250 245 275 RM 112 A B 1 SW 12X8 2 SW 12X8 1.0 C 3 CD 6X6 1.0 1.0 250 325 250 242 75 120 I'1'L 575 689 279 265 96 1'I'L 640 Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: ABU AIR OUTLET DATA SHEET Date: 06/08/12 Page: 65 Floors 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 113 A B 1 SW 12X8 1.0 250 290 271 2 SW 12X8 1.0 250 234 261 C 3 CD 6X6 1.0 75 110 94 TTL 575 634 1 1L 626 RM 114 A 1 SW 12X8 1.0 200 215 210 B 2 SW 12X8 1.0 150 190 170 C 3 SW 12X8 1.0 D 4 SW 12X8 1.0 E 5 CD 10X10 1.0 150 205 175 200 185 204 100 106 110 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET OUTLET NO. TYPE SIZE AREA RM 201 A B C RM 202 A B C RM 203 A B C D E DESIGN Date: 06/05/12 Page: 66 Floor: 2 TEST CFM MEASURED FPM CFM #1 #2 FPM 1 SW 6X10 1.0 250 335 2 SW 6X10 1.0 250 268 3 CD 6X6 1.0 75 131 1 f 575 734 I1'L 280 277 110 657 1 SW 6X 10 1.0 250 241 2 SW 6X10 1.0 250 380 3 CD 6X6 1.0 75 130 ITL 575 751 275 285 111 671 1 SW 6X10 1.0 200 195 2 SW 6X10 1.0 150 195 3 SW 6X10 1.0 150 206 4 SW 6 X 10 1.0 200 230 5 CD 8X8 1.0 100 46 1 1'L 800 892 Comments: Readings By: Bart Serino 210 140 162 198 80 790 11'L aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 67 Floor: 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED RM 204 A B RM 205 A B C RM 207 NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 1 SW 16X6 1.0 400 589 CD t TTL 475 723 1 SW 6 X 10 1.0 250 340 2 SW 6X10 1.0 250 233 658 3 CD 6X6 1.0 75 123 TTL 575 696 240 259 102 1"1'L 601 1 "1'L 575 703 '! TL 642 Comments: Readings By: Bart Serino CTB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 68 Floor: 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 208 A 1 SW 6 X 10 1.0 2 SII! e X 10 1.0 CD 250 328 270 250 75 95 TTL 575 683 FIL 642 RM 209 A 1 SW 6X10 1.0 250 329 271 B 2 SW 6 X 10 1.0 250 235 265 C RM 210 CD 6X6 1.0 75 98 97 I IL 575 662 1 °l'L 633 A 1 SW 6 X 10 1.0 250 365 282 B 2 SW 6 X 10 1.0 250 260 310 C 3 CD 6X6 1.0 75 156 92 ITL 575 781 TTL 684 Comments: Readings By: Bart Serino GB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 69 Floor .2 AREA SERVED NO. TYPE SIZE AREA FPM OUTLET DESIGN TEST CFM MEASURED CFM #1 #2 FPM CFM RM 211 A B 1 SW 6 X 10 1.0 250 295 283 2 SW 6 X 10 1.0 250 347 291 3 CD 6 X 6 1.0 75 140 99 1 I L 575 782 I IL 673 RM 212 A B 1 SW 6 X 10 1.0 2 SW 6 X 10 1.0 3 CD 6 X 6 250 290 273 250 105 267 1.0 75 310 97 TTL 575 705 1 L 637 RM 213 A 1 SW 6 X 10 1.0 250 295 202 B 2 SW 6 X 10 1.0 250 296 285 3 CD 6 X 6 1.0 75 110 97 I IL 575 750 IrL 644 Comments: Readings By: Bart Serino CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA SERVED AIR OUTLET DATA SHEET OUTLET Date: 06/05/12 Floor: 2 DESIGN TEST CFM Page: 70 MEASURED NO. TYPE SIZE AREA CFM #1 #2 FPM CFM RM 214 A B C D E 1 SW 6X10 1.0 200 285 230 2 3 4 SW SW SW 5 CD 6 X 10 6X10 6X10 8X8 1.0 1.0 1.0 I.0 150 210 150 208 200 219 1°l'L 100 95 800 1017 179 190 189 107 874 1 1L 227 167 169 215 107 885 Comments: Readings By: Bart Serino CTB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/06/12 Page: 71 Floor. 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 231 1 CD 10X 10 1.0 2 CD 10 X10 1.0 74 81 RM 234 RM 235 1 CD 10 X 10 1.0 2 CD 10X10 1.0 1 CD 10X 10 1.0 1 CD 10 X 10 1.0 68 70 83 84 2 CD 10 X10 1.0 85 RM237 1 CD 10X10 1.0 79 2 CD 10X10 1.0 85 Comments: Readings By: Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA SERVED AIR OUTLET DATA SHEET OUTLET Date: 06/05/12 Page: 72 Floor: 2 DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM A 1 SW 6 X 10 1.0 350 278 B 2 SW 6X10 1.0 CD 6X6 1.0 289 282 A 1 SW 6X10 1.0 350 280 B 2 SW 6 X 10 1.0 CD 6X6 1.0 250 275 110 108 11'L 575 SW 6 X 10 1.0 SW 6 X 10 1.0 C 3 SW 6 X 10 1.0 D 4 SW 6 X 10 1.0 195 204 248 155 CD 8 X 8 1.0 245 179 274 201 1 "1'L 800 Comments: Readings By: Bart Serino CrB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AIIU AIR OUTLET DATA SHEET Date: 06/06/12 Page: 73 Floor: 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 234 A B RM 235 A B 1 SW 6 X 10 1.0 400 520 504 2 CD 6 X 6 1.0 1 SW 6 X 10 1.0 2 SW 6 X 10 1.0 3 CD 6 X 6 1.0 75 TTL 475 250 250 110 97 630 TM 601 302 260 265 275 75 96 98 TTL 575 663 633 RM 237 A 1 SW 6 X 10 1.0 B 2 SW 6 X 10 1.0 C3CD6X6I.0 250 250 75 360 272 241 276 120 11L 575 721 99 647 RM 238 A 1 SW 6 X 10 1.0 250 296 276 B 2 SW 6 X 10 1.0 250 254 263 C 3 CD 6 X 6 1.0 75 105 99 I IL 575 655 I IL 638 Readings By: Bart Serino cm CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/05/12 Page: 74 Floor. 2 AREA SERVED OUTLET DESIGN TEST CFM NO. TYPE SIZE AREA FPM CFM #1 #2 RM 239 A B C RM 240 A B C RM 241 A B C 1 SW 6 X 10 1.0 250 330 2 SW 6 X 10 1.0 250 257 3 CD 6X6 1.0 75 105 TTL 575 692 "1TL 279 276 96 651 1 SW 6X 10 1.0 250 320 2 SW 6 X 10 1.0 250 255 3 CD 6X6 1.0 75 130 TTL 575 705 11L 277 279 96 652 1 SW 6X10 1.0 250 315 2 SW 6X 10 1.0 250 260 3 SW 6X6 1.0 75 120 .F1'L 575 695 1`1L 278 272 99 649 Comments: Readings By: Bart Serino cm CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06106/12 Page: 75 Floor: 2 AREA SERVED NO. TYPE SIZE RM 242 A B C RM 243 A B C RM 244 A B C D E AREA FPM TEST CFM CFM #1 #2 1 SW 6 X 10 1.0 250 321 MEASURED FPM CFM 2 3 SW 6X 10 CD 6X6 1.0 1.0 TTL 250 75 575 291 170 782 l_l.L 281 275 101 657 1 SW 6X 10 1.0 250 290 2 SW 6 X 10 1.0 250 300 3 CD 6X6 1.0 75 101 'ITL 575 691 1'1'L 276 269 103 648 1 SW 6X 10 1.0 200 214 2 SW 6 X 10 1.0 150 210 3 SW 6 X 10 1.0 150 197 4 5 SW 6 X 10 CD 8X8 1.0 200 200 1.0 100 89 800 910 Comments: Readings By: Bart Serino Y1'L 217 178 174 221 95 885 aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY AIR OUTLET DATA SHEET Date: 06/07/12 Page: 76 System: AHU Floor: 3 AREA OUTLET DESIGN SERVED NO. TYPE SIZE AREA FPM CFM TEST CFM MEASURED #1 #2 FPM CFM RM 301 A 1 SW 6 X 10 1.0 250 275 B 2 SW 6 X 10 1.0 250 346 C 3 CD 6 X 6 1.0 75 120 281 279 88 TTL 575 741 '1'1L 648 RM 302 A 1 SW 6 X 10 1.0 B 2 SW 6X 10 1.0 C 3 CD 6X6 1.0 250 297 250 320 75 111 275 281 81 1'I'L 575 725 I IL 637 A 1 SW 6 X 10 1.0 B 2 SW 6X 10 1.0 200 197 150 167 205 155 C 3 SW 6 X 10 1.0 150 234 160 D 4 SW 6 X 10 1.0 E 5 CD 8X8 200 191 209 1.0 100 82 101 1'iL 800 891 1'i'L 830 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06107/12 Page: 77 Floor: 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 304 t 1 TTL 475 622 11L 589 RM 305 A 1 SW 6X10 1.0 B C 2 SW 6X10 1.0 250 250 3 CD 6X6 1.0 75 325 278 315 275 109 81 A 1 SW 6X 10 1.0 B 2 SW 6X10 1.0 C 3 CD 6X6 1.0 RM 308 250 250 75 rrL 575 292 281 107 80 724 1 I 643 A 1 SW 6 X 10 1.0 B 2 SW 6X10 1.0 C 3 CD 6X6 1.0 Readings By: Craig Maurer 250 250 75 I IL 575 264 269 378 286 101 82 743 637 aB CERTIFIED TEST & BALANCE AIR OUTLET DATA SHEET Project: BARRY UNIVERSITY System: AHU AREA OUTLET SERVED NO. TYPE SIZE T RM 309 Date: 06/07/12 Page: 78 Floor: 3 DESIGN TEST CFM AREA FPM 250 263 281 C 3 CD 6X6 1.0 75 125 575 77.11111 250 345 275 A B 2 SW 6X 10 1.0 C RM 311 A B C RM 312 A B 2 SW 6X10 1.0 C 3 1 SW 6X10 1.0 80 250 287 272 3 CD 6X6 1.0 75 131 85 1 1L 575 763 11'L 632 1 SW 6 X 10 1.0 250 339 279 2 SW 6X 10 1.0 3 CD 6X6 1.0 TTL 250 305 283 75 96 81 575 740 11'L 643 1 SW 6X10 1.0 250 401 289 250 272 286 CD 6X6 1.0 75 129 84 TIT, 575 802 1 °IL 659 Readings By: Craig Maurer as CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/07112 Page: 79 Floor: 3 TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 6 X 10 1.0 200 198 6 X 10 1.0 150 165 301 TOILET SHOWER 10 X 10 10 X 10 Readings By: Craig Maurer cm CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET OUTLET NO. TYPE SIZE AREA DESIGN FPM Date: 06/07/12 Page: 80 Floor 3 CFM #1 1 CD 10X 10 1.0 1 CD 10X 10 1.0 1 CD 10X 10 1.0 1 CD 10X 10 2 CD 10X 10 1.0 1.0 1 CD 10X 10 2 CD 10X 10 1.0 1.0 1 CD 10X 10 1.0 2 CD 10X 10 1.0 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/07/12 Floor: 3 TEST CFM Page: 80A NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CD 10 X 10 1.0 79 CD 10X10 1.0 82 CD 10 X10 1.0 81 CD 10 X10 1.0 84 CD 10X10 1.0 75 CD 10 X 10 1.0 82 RM314 CD 10 X 10 1.0 79 CD 10 X10 1.0 87 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/07/12 Page: 81 Floor: 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 331 SW 6 X 10 1.0 250 350 280 SW 6 X 10 1.0 250 277 275 CD 6X6 1.0 75 96 99 575 723 IIL 654 SW 6 X 10 1.0 250 351 273 SW 6 X 10 1.0 250 243 284 CD 6X6 1.0 75 110 105 I"I'L 575 704 I"1L 662 SW 6 X 10 1.0 200 202 230 SW 6 X 10 1.0 150 243 167 SW 6 X 10 1.0 150 203 170 D 4 SW 6 X 10 1.0 200 225 222 E 5 CD 8X8 1.0 100 69 94 1'1L 800 945 7 "I'L 883 Comments: Readings By: Bart Serino CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/07/12 Page: 82 Floor:3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM334 A 1 SW 6 X 10 1.0 400 505 499 CD 75 EFL 475 599 1'1'L 589 RM 335 A 1 SW 6 X 10 1.0 250 340 289 B 2 SW 6X10 1.0 250 260 275 C 3 CD 6X6 1.0 75 120 98 TTL 575 720 1 TL 662 RM337 B 2 SW 6X10 1.0 250 228 265 C 3 CD 6X6 1.0 75 130 94 1 "1L 575 708 1'1L 639 RM 338 A 1 SW 6X 10 1.0 250 292 285 B 2 SW 6 X 10 1.0 250 330 280 C 3 CD 6X6 1.0 75 130 109 11L 575 752 674 Readings By: Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: AHU AIR OUTLET DATA SHEET Date: 06/07/12 Page: 83 Floor: 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 339 A B 2 SW 6X 10 1.0 C RM 340 A B 2 SW 6 X 10 1.0 C 3 RM 341 1 SW 6X10 1.0 250 360 281 250 219 3 CD 6 X 6 1.0 75 98 !IL 575 677 '1"1'L 276 96 653 1 SW 6 X 10 1.0 250 333 283 250 246 279 CD 6X6 1.0 75 107 97 TTL 575 688 1 1L 659 A B C 1 SW 6 X 10 1.0 250 320 277 2 SW 6X10 1.0 250 239 274 3 CD 6X6 1.0 75 101 96 fIL 575 660 TTL 647 Comments: Readings By: Bart Serino GB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: ABU AIR OUTLET DATA SHEET Date: 06/07/12 Page: 84 Floor .3 AREA SERVED NO. OUTLET DESIGN TEST CFM MEASURED TYPE SIZE AREA FPM RM 342 A 1 SW 6 X 10 1.0 SW 6 X10 1.0 3 CD 6 X 6 1.0 CFM #1 #2 FPM CFM 250 250 75 330 240 105 TTL 575 675 279 281 99 11L 659 RM 343 A B 1 SW 6 X 10 1.0 250 2 SW 6 X 10 1.0 C 3 CD 6 X 6 1.0 RM 344 A 1 SW 6 X 10 1.0 B 2 SW 6 X 10 1.0 C 3 SW 6 X 10 1.0 D E 4 SW 6 X 10 1.0 331 250 270 75 120 TTL 575 721 200 150 150 200 273 288 98 IIL 661 190 198 165 183 5 CD 8 X 8 1.0 100 93 ITL 800 829 192 167 160 191 99 ITL 809 Comments: Readings By: Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/4)8/12 Page: 85 Floor:1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO TYPE SIZE AREA RM 101 TOILET 1 EF 12 X 12 1.0 SHOWER 2 EF 12 X 12 1.0 RM 102 TOILET 1 EF 12 X 12 1.0 SHOWER 2 EF 12 X 12 1.0 RM 103 FPM CFM #1 #2 FPM CFM 50 74 50 90 50 84 50 71 TOILET 1 EF 12 X 12 1.0 50 75 SHOWER 2 EF 12 X 12 1.0 50 80 RM 104 RM 105 TOILET 1 EF 12 X 12 1.0 SHOWER 2 EF 12 X 12 1.0 RM 107 TOILET 1 EF 12 X 12 1.0 SHOWER 2 EF 12 X 12 1.0 50 46 50 84 Comments: Readings By: Craig Maurer CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/9/12 Page: 86 Floor: 1 AREA SERVED OUTLET DESIGN TEST CFM MEASURED RM 108 TOILET NO TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 1 EF 12 88 SHOWER 2 EF 12 X 12 1.0 50 76 RM 109 TOILET 1 EF 12 X 12 1.0 50 83 SHOWER 2 EF 12 X 12 1.0 50 88 RM 110 TOILET 1 EF 12 X 12 1.0 50 82 SHOWER 2 EF 12 X 12 1.0 50 83 RM 111 TOILET 1 EF 12 X 12 1.0 50 77 SHOWER 2 EF 12 X 12 1.0 50 83 RM112 TOILET 1 EF 12 X 12 1.0 50 88 SHOWER 2 EF 12 X 12 1.0 50 83 RM 113 TOILET 1 EF 12 X 12 1.0 50 77 SHOWER 2 EF 12 X 12 1.0 50 81 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AREA SERVED AIR OUTLET DATA SHEET Date: 0619112 Page: 87 Floor: 1 DESIGN TEST CFM MEASURED NO TYPE SIZE AREA FPM CFM #1 #2 FPM CFM TOILET SHOWER Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/06/12 Page: Floor: 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 201 1 CD 10 X 10 1.0 70 2 CD 10 X10 86 RM 202 1 CD 10 X 10 74 2 CD 10X10 77 RM 203 1 CD 10 X 10 85 RM 204 CD 10 X 10 74 RM 207 1 CD 10X10 1.0 77 2 CD IOX 10 1.0 79 RM 208 1 Comments: CD 2 CD Readings By: Bart Serino 10 X10 1.0 10 X10 1.0 74 78 aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/06/12 Page: 89 Floor. 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED RM 209 NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 1 CD 10 X 10 1.0 CD 10 X 10 RM s 1 CD 10X10 1.0 2 CD 10X10 1.0 80 78 RM 211 CD 10 X 10 1.0 2 CD 10 X 10 1.0 75 76 RM 212 1 CD 10 X 10 1.0 80 2 CD 10X 10 1.0 83 RM 213 1 CD 10X 10 1.0 81 2 CD 10X10 1.0 83 RM 214 1 CD 10X10 1.0 83 2 CD 10 X 10 1.0 75 Comments: Readings By: Bart Serino GB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06 /06/12 Page: 9 0 Floor: 2 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 238 1 CD 10X 10 1.0 85 2 CD 10 X 10 1.0 84 RM 239 1 CD 10 X 10 2 CD 10 X 10 1.0 85 1.0 81 RM 240 1 CD 10X 10 1.0 90 2 CD 10 X10 1.0 45 RM 241 1 CD 10X 10 1.0 84 CD 10X 10 1.0 80 RM 242 1 CD 10 X 10 1.0 86 2 CD 10x10 1.0 81 RM 243 1 CD 10X10 1.0 65 2 CD 10X10 1.0 77 Comments: Readings By: Bart Serino •cn3 CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF - 1 AREA SERVED AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/07/12 Page: 91 Floor: 2 TEST CFM MEASURED NO. TYPE SIZE AREA #1 #2 FPM CFM RM 244 1 2 CD CD 10 X 10 1 0 X 10 1.0 1.0 78 80 Comments: Readings By: Bart Serino Cri3 CERTIFIED TEST & BALANCE AIR OUTLET DATA SHEET Project: BARRY UNIVERSITY System: EF -1 Date: 06/09112 Page: 92 Floor: 3 DESIGN TEST CFM NO TYPE SIZE AREA FPM CFM #1 #2 Comments: Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AREA SERVED AIR OUTLET DATA SHEET OUTLET Date: 06/09/12 Floor. 3 DESIGN TEST CFM Page: 93 MEASURED NO TYPE SIZE AREA FPM CFM #1 #2 FPM CFM RM 308 TOILET 1 EF 12 X 12 1.0 50 76 SHOWER 2 EF 12X12 1.0 50 85 RM 309 TOILET 1 EF 12 X 12 1.0 50 81 SHOWER RM 310 TOILET SHOWER 2 EF 12X 12 1.0 50 84 1 EF 12 X 12 1.0 50 79 2 EF 12X12 1.0 50 82 RM 311 TOILET 1 EF 12 X 12 1.0 50 81 SHOWER 2 EF 12 X 12 1.0 50 84 1 EF 12 X 12 1.0 50 2 EF 12X 12 1.0 50 1 EF 12 X 12 1.0 50 Readings By: Craig Maurer aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET OUTLET DESIGN Date: 06/08/12 Page: 94 Floor: 3 TEST CFM NO TYPE SIZE AREA FPM CFM #1 #2 FPM 1 EF 2 EF 12 X 12 1.0 12 X 12 1.0 50 50 Comments: Readings By: Craig Maurer x CM CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/07/12 Page: 95 Floor. 3 NO. TYPE SIZE AREA FPM CFM 1 CD 10X 10 1.0 RM 332 1 CD 10 X10 1.0 1 CD 10 X 10 1.0 88 1 CD 10X 10 1.0 2 CD 10 X 10 RM 337 2 CD 10 X 10 1.0 84 Comments: Readings By: Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 AIR OUTLET DATA SHEET Date: 06/07/12 Page: 96 Floor 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO. TYPE RM 338 SIZE AREA FPM CFM #1 #2 FPM CFM 1 CD 10X10 1.0 79 2 CD 10 X 10 1.0 81 RM 337 1 CD 10X10 1.0 78 2 CD 10X10 1.0 84 RM 340 1 CD 10 X 10 1.0 82 2 CD 10 X 10 1.0 83 RM 341 1 CD 10X 10 1.0 81 2 CD 10 X 10 1.0 83 RM 342 1 CD 10 X 10 1.0 83 2 CD 10 X 10 1.0 85 RM 343 1 CD 10 X 10 1.0 84 2 CD 10X10 1.0 67 Comments: Readings By: Bart Serino aB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 TRASH CHUTE AIR OUTLET DATA SHEET Date: 06/08/12 Page: 97 Floor: 2N° & 3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED NO TYPE SIZE AREA FPM CFM #1 #2 FPM CFM 214D FL 1 EG 714X714 .39 256 100 313/121 274 107 3RD FL 2 EG 71/2X 7Y2 39 256 100 285/111 282 110 200 217 Comments: Readings By: Craig Maurer CTB CERTIFIED TEST & BALANCE Project: BARRY UNIVERSITY System: EF -1 0 AIR OUTLET DATA SHEET Date: 06/08/12 Page: 98 Floor: 1 -3 AREA SERVED OUTLET DESIGN TEST CFM MEASURED RM 319 NO. TYPE SIZE AREA FPM CFM #1 #2 FPM CFM JANITOR 1 CD 10X10 1.0 50 51 RM 119 JANITOR 1 CD 10 X 10 1.0 50 51 Comments: Readings By: Bart Serino Abbreviations AC Air Conditioning Unit LD Linear Diffuser. AHU Air Handling Unit LWT Leaving Water Temperature BHP Brake Horsepower MAU Make -up Air Unit CD Ceiling Supply Diffuser MAX Maximum CFM Cubic Feet Per Minute MIN Minimum CHWR Chilled Water Return NA Not Applicable CHWS Chilled Water Suppply NI Not Installed CWR Condenser Water Return NS Not Stated CWS Condenser Water Supply OBD Opposed Blade Damper DD Direct Drive OD Outside Diameter DP Differential Pressure OA Outside Air EAT(DB) Entering Air Temp.(Dry Bulb) RA Return Air EAT(WB) Entering Air Temp.(Wet Bulb) REQ'D Required EF Exhaust Fan RG Return Grille ESP External Static Pressure RH Relative Humidity EWT Entering Water Temperature RPM Rotations Per Minute FCU Fan Coil Unit RTU Rooftop Unit FLA Full Load Amps SA Supply Air FPB Fan Powered Box SF Safety Factor FPM Feet Per Minute SLOT Slot Diffuser GPM Gallons Per Minute SP Static Pressure HP Horsepower SWR Side Wall Register HPACU Heat Pump AC Unit TSP Total Static Pressure HWR Heated Water Return T -STAT Thermostats or Sensor HWS Heated Water Supply TYP Typical ID Inside Diameter V.D. Volume Damper INAC Inaccessible VAV Variable Air Volume LAT(DB) Leaving Air Temp(dry bulb) VFD Variable Frequency Drive LAT(WB Leaving Air Temp(wet bulb) WSHP Water Source Heat Pump GB CERTIFIED TEST & BALANCE INSTRUMENT CALIBRATION DATA SHEET INSTRUMENT SERIAL NUMBER DATE CALIBRATED DATES OF USE FLUKE 51 TEMPERATURE MEASUREMENT 6574136 1/5/12 NA FLUKE SOPK 2A IMMERSION 7297 -1 1/5/12 NA FLUKE 80PK 3A SURFACE 7297 -2 1/5/12 NA FLUKE 322 VOLTAGE /AMPERAGE 85760374 9/3/11 06/01/12 EXTECH RH390 % RELATIVE HUMIDITY 09059988 1/5/12 06/01/12 SHORTRIDGE ADM- 860 FLOOW HOOD M01378 8/22/11 06/16/12 HE STICHT 4401 -H ROTATIONAL SPEED 85069 9/3/11 06/01/12 TESTO 417 AIR VELOCITY MEASUREMENT 02128816 9/3/11 06/01/12 SHORTRIDGE HDM- 300 WATER FLOW MEASUREMENT W98051 4/5/11 NA Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 JUL 1 & Re'Dcj& pern,i,Norn�11-ia83 Master Permit No. 1 ` - 5 AL Permit Type: MECHANICAL OWNER: Name (Fee Simple Titleholder): �,22 �e�cri kev)..'4,tc..$,A,�41 Phone#: 305 '-$`i'i —305t Address: a301, g0F_ %h ,. yy City: tAt,;J' \ � 4 State: ft,— Zip: 33MM 1 Tenant/Lessee Name: ` ` �a., � ` et c , \.1 Phone#: .Sc – 3o9 Email: % �%r�'vla �?5 G 4\ • )nor,N- JOB ADDRESS: )11 ItY0 City: Miami Shores County: Miami Dade Zip: VL 1 Folio/Parcel #: Ws.,Q 3 , GOCW Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: / / 1 , *it, , Phone #: 494 "S6 gri Address: J 5 5. And t au City: / i 1LLIV[f do state: Qualifier Name: M ,( i'1-- K 1C../rniq � -� State Certification or Registration #: oo X/ %0 Zip: 333/40 Phone#: �j Certificate of Competency #: /23--23(1k i '1 Contact Phone#: c 5 /4. E2.5 — Zq' J Email Address: DESIGNER: Architect/Engineer: ice' ; f/ 1/ %r k Gl5unn4lrsoft a h; LI'j rk. (N\ Phone #: 4,511°- 6-2 -247/ Value of Work for this Permit: $ f 1SC OC:d Square/Linear Footage of Work: *New ORep '/Replace ODemolition Type of Work: UAddress A OAlteration . I I� p Description of Work: a A- I k ((�'JL t �} )C.- j tikl )I ` r Pi cti4- C� uta i�� W 0+1 ar O E i 1M! I-AAC' W kg:7 ******** * * * * * * * * * * * * * * * * * *$ ** * * * * * * * * ** e * ** ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit F 31k b CCF $ CO /CC $ Radon Fee $ DBPR $ Bond $ Technology Fee $ Submittal Fee $ Scanning Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE -71 tt T-tg Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved reinspection fee will be charged. 411 Signature Sr, Owner or Agent y'� The foregoing instrument was acknowledged before me this /3 The foregoing instrument was acknowledged before me this 2 ' day of S 1-7 , 20 it , by 0, r3. �4.4, ���� �,� - day of \tA , 2011 d , by Ivy COIL I t , who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Signature L+ Contractor Sign: Print: t1 L � '�-�✓t� � �e'� My Commission Expires: APPROVED BY �V �u�� Notary Public State of Florida 4 Cheryl Saida Gerber My Commiss on 01396131213 ?ofpoC Expires 05108/2014 Sign: Print: My Commission Exp. O ° ": MY COMMISSION # DD702722 -.•; ,8, f, EXPIRES August 07, 2011 (407) 398 -0153 FloridallotaryService.com *********************** ****** *** * * * * * * * * ***** * ****+k** niner Zoning Structural Review (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Clerk