Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-11-586 (2)
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 157904 Permit Number: CC -4 -11 -586 Scheduled Inspection Date: January 11, 2012 Inspector: Rodriguez, Jorge Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue NEW DOORM Miami Shores, FL 33138 -0000 Project BARRY UNIVERSITY Contractor: MOSS & ASSOCIATES LLC Permit Type: Commercial Construction Inspection Type: Slab Work Classification: New Phone Number Parcel Number 1121360010160 -37 Phone: (954)410 -3250 Building Department Comments CONSTRUCTION OF A NEW THREE STORY BUILDING: 247 BED RESIDENCE, HALL APPROX 72,000 SQFT INCLUDING NEW PARKING. Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. January 10, 2012 For Inspections please call: (305)762.4949 Page 2 of 37 0 TER. ERMITE PRETREAT SPECIALISTS 866-PRE-TREAT 1-800-DILIGENT FAX 800 -837 -0311 TermitePretreat.com State License 150612 Notice of Preventative Treatment for Termites (as required by Florida Building Code (FBC) 104.2.6 and Broward County Chapter FBC 105.2.2) PEST PREVENTION I LAWN & ORNAMENTAL CARE I TERMITE SERVICES I MOSQUITO ABATEMENT I RODENT EXCLUSION & REMOVAL zS7/9/11 TREATMENT TYPE/AREA :GATING CUTOUTS TREATMENT TYPE ❑ TAMP & TREAT ❑ MONOLITHIC ❑ FOOTERS ❑ PATIO ❑ FRONT ENTRY ❑ GARAGE ❑ DRIVEWAY ❑ STEM WALL ❑ EXTERIOR PERIMETER FOR RENEWAL ❑ OTHER ❑ ADDITION TREAT ONLY ❑ FINAL ❑ RETREAT ❑ BORA CARE TREATMENT ❑ BAIT STATION PR UCT BASELINE ❑ PROBUILD TC ❑ DRAGNET ❑ DEMON TC ❑ TERMIDOR TC ❑ BORACARE ❑ OTHER .ACTIVE INGREDIENT CONCENTRATION ❑ .06% ❑ .12% ❑ .25% ❑ .5% ❑ .23% ❑ OTHER GALLONS APPLIED ARE FOOTAGE VERIFIED YES ❑ NO JOB Y CONDITIONS MET YES ❑ NO 0 1.INEAR FOOTAGE ❑ MEASURED OR VERIFIED PER PLANS DETAILS SAFETY CONDITIONS 0 As per 104.2.6 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is In accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services. (Per the Florida Building Code.) If this notice is for the final exterior treatment, initial and date this line FINAL STICKER ❑ ELECTRICAL PANEL ❑ WATER HEATER OTHER Payment Terms.. C,,.._ s payment �n r.Il 's 1ue at time of initial serrce C.;st,�mer 3yrees that a finance .harge ,n the ar'D r't of 13', per annum wfil ' I u ce a ti .at a(a ;Y ,d i ,t' . by the date. it .re .v .r, 3 _,:ilect :on process becomes necessari r-a r.�r r,er 3n unpa d assn d .n ; J rg Put rot I ed to collection. sen,oce fee, attorneys fea firanr_■ merges 31`11 -,ors- suit clew. funds r :, "i __ re>J)crSI - r rg 3! .associated Nth 3r.yc.,_cuon process. Date Customer (Prope ° Owner or Agent) ,OAS■ t KAHB Ste Corporate 3100 NW Boca Raton Blvd. 1 Suite 107 I Boca Raton, Florida 33431 1 800.487.8190 00-DILIGENT 0 iligeilltco Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 nspection Number: INSP- 177456 Permit Number: CC -4 -11 -586 Inspection Date: August 16, 2012 Inspector: Bruhn, Norman Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue NEW DOORM Miami Shores, FL 33138 -0000 Project BARRY UNIVERSITY Contractor: MOSS & ASSOCIATES LLC Permit Type: Commercial Construction Inspection Type: Final PE Certification Work Classification: New Phone Number Parcel Number 1121360010160 -37 Phone: (954)410 -3250 Building Department Comments CONSTRUCTION OF A NEW THREE STORY BUILDING: 247 BED RESIDENCE, HALL APPROX 72,000 SQFT INCLUDING NEW PARKING. Passed 1,e— Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until For Inspections please call: (305)762 -4949 August 16, 2012 Page 1 of 1 October 31, 2011 Moss & Associates Attn: Ms. Sherry Werner Barry University (Residence Hall Project) 11300 NE 2nd Avenue Miami Shores, Florida 33161 RE: Barry University Dorms Structural Steel Special Inspections Permit #: 11 -586 JSG #: 11066 Dear Ms. Werner, ;JOHNSON I TRucruRAL Johnson Structural Group, Inc. has performed Special Inspections for the structural steel members and corresponding steel connections at the above captioned project. Our inspections of the structural steel occurred between September 26, 2011 and October 31, 2011 and included the ground, second floor, third floor, roof level and elevator shaft structural steel framing. Copies of our inspection reports are attached for reference. To the best of our belief, the work described above was completed in accordance with the permitted documents and the Florida Building Code 2007. Please do not hesitate to contact this office if you have any questions regarding this matter. Sincerely, JOHNSON STRUCTURAL GROUP, INC. Mark Johnson, P.E., SECB Florida PE# 51983 President CC: Mr. Norman Bruhn 11066 STRUCTURAL STEEL INSPECTION LE 11 ER 10 -28 -11 951 Yamato Road, Suite 205 • Boca Raton, FL 33431 phone 561 - 982 -8999 • fax 561- 982 -8899 • www.johnsonstructural.com Johnson Structural Group, Inc. / Moss & Associates OB NAME: PERMIT # CITY: Barry University Residence Hall Contractor: 11 -586 Miami Shores Village STATE: Moss & Associates Florida INSPECTOR: WEATHER: DATE: TIME: L . COLUMN INSPECTIONS fir Column Grid f�� a t�lr ', r!1• 'Y � �-L^ Column Grid Checked Anchor Bolts Extension Grout Below Plate �_ our Back of Diamond , ,_ f`, 7 Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Johnson Structural Group, Inc. / Moss & Associates OB NAME: Barry University Residence Hall Contractor: Moss & Associates PERMIT # 11 -586 CITY: Miami Shores Village STATE: Florida INSPECTOR: _ . i ; � , ' L . DATE: WEATHER: L:.+ t r `7 TIME: COLUMN INSPECTIONS Column Grid Checked 1- Anchor Bolts Extension L; -y Grout Below Plate Pour Back of Diamond Column Grid Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Checked Column Grid Checked Anchor Bolts Extension ,Grout Below Plate Pour Back of Diamond Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Column Grid Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Checked Column Grid Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Checked Column Grid Checked Anchor Bolts Extension Grout Below Plate Pour Back of Diamond Johnson Structural Group, Inc. / Moss & Associates JOB NAME: PERMIT # CITY: Barry University Residence Hall Contractor: Moss & Associates 11 -586 Miami Shores Village STATE: Florida INSPECTOR: ro ;•. t :=t• �`° DATE: WEATHER: °• ,s: ?., 1 TIME: i BEAM INSPECTIONS (No Moment Connections Beam Floor �— CL Beam Span J -(l Check Connection Per Plan ,./ If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts -8 # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected - -t P:r Beam Floor Beam Span Checked / Comment Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected Beam Floor Beam Span Checked / Comment Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected Beam Floor Beam Span Checked / Comment Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts #.of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected Johnson Structural Group, Inc. / Moss & Associates JOB NAME: Barry University Residence Hall Contractor: PERMIT # 11 -586 CITY: Miami Shores Village STATE: Moss & Associates Florida INSPECTOR: WEATHER: 4712'. t DATE: i ; ',� TIME: : ;� t'r'•� Beam Floor Beam Span �- • t 1 b _ BEAM INSPECTIONS (No Moment Connections Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts " ; "_ P 1 - if # of Bolts - All Holes Filled 1.,_----- 1. r All Plies Brought Together 17" Size and Length of Weld Visual Weld Inspected I 73 "-'0,,;r*: •q �^ f e Beam Floor Checked / Comment Beam Span Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected -1- ;14_ r� %1`i ' 1 / 7 Beam Floor Beam Span Checked / Comment Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected Beam Floor Checked /Comment Beam Span Connection Per Plan If Not Per Plan, Per Detail If not Per Detail, EOR Notified? Diameter of Bolts # of Bolts - All Holes Filled All Plies Brought Together Size and Length of Weld Visual Weld Inspected 1 Return Inspection Result Comments Saturday, August 11, 2012 http:// bldgadmin. miamidade .gov /MDFR/CommentRptPrint.asp ?Permit.. Permit Number: 2011044180 Date: Inspector: Type: Status: 8/10/2012 Tumaini Jabali ( JABALIT) 209 - FIRE FINAL 1 - APPROVED PERMIT# 2011044180 11441 NW 2 AVE BARRY UNIVERSITY DOMINICAN HALL 1. FIRE FINAL APPROVED. 2. ALL ITEMS FROM PREVIOUS LIST HAVE BEEN CORRECTED. Date: Inspector: Type: Status: 8/9/2012 Tumaini Jabali (JABALIT) 209 - FIRE FINAL 3 - REJECTED NOT TO CODE PERMIT# 2011044180 11441 NW 2 AVE BARRY UNIVERSITY DOMINICAN HALL 1. FIRE FINAL NOT APPROVED. 2. ALL ITEMS FROM PREVIOUS LIST BY LT. WRAY DATED 6/27/12 THAT WERE PENDING FROM LT. HUNT S LIST HAVE BEEN COMPLETED EXCEPT: ITEM #6 & #54 PLAN REVISION FOR FIRE ALARM PLANS. PLANS HAVE BEEN REVISED HOWEVER ANY ADDITION OR ALTERATION OF APPROVED PLANS OR SPECS SHALL BE APPROVED IN ADVANCE BY THE AHJ, AS EVIDENCED BY THE ISSUANCE OF A NEW OR AMENDED PERMIT. FIRE ALARM PERMIT# 2012016884 PROCESS# M2012008674 FOR FIRST REVISION, SECOND REVISION DOES NOT HAVE A PROCESS NUMBER. PROVIDE FIRE ALARM PERMIT THAT WAS SIGNED AND APPROVED BY INSPECTOR. SPRINKLER HAS BEEN APPROVED BY PREVIOUS INSPECTOR. ITEM #52 PROVIDE EM CONTACT INFORMATION AT MAIN ENTRANCE. ITEM #9 PROVIDE DIRECTIONAL EXIT SIGNAGE AT 1 ST FLOOR LANDING ILLUMINATED. NFPA 101: 7.10. EVERY SIGN REQUIRED IN SEC 7.10 SHALL BE LOCATED AND OF SUCH SIZE, DISTINCTIVE COLOR AND DESIGN THAT IT IS READILY VISIBLE. NFPA 101: 7.10.8 ACCESS TO EXITS SHALL BE MARKED BY APPROVED, READILY VISIBLE SIGNS IN ALL CASES WHERE THE EXIT OR WAY TO REACH THE EXIT IS NOT READILY APPARENT TO OCCPANTS. NFPA 101: 7.10.1.5.1 3. PAY RE- INSPECTION FEE. Date: Inspector: Type: Status: 6/27/2012 Walter Wray (WRAYWW) 208 - FIRE TCO INSPECTION 47 - APPROVED FOR TEMPORARY ONLY 1 of 7 8/11/2012 9:37 AM http: //bldgadmin.miamidade govMIDFRlCommentRptPrint.asp ?Permit.. 1. TCO RECOMMENDED PENDING CAPTAIN S APPROVAL 2. ALL ITEMS FRM LT HUNT S LIST COMPLETED EXCEPT FOR THE FOLLOWING: - ITEM #4 - EXT. EM LIGHTING WAS INSTALLED AT 2 EXIT DISCHARGES FOR THE STAIRS. NEED EXT. EM LIGHTING AT EAST & WEST EXIT DOORS - ITEMS #6 & 54 ARE PENDING F/A PLAN REVISION - ITEM #19 - EXIT SIGNS WERE INSTALLED BUT ARE NOT THE ILLUMINATED SIGNS - ITEM #34 - CURRENTLY, YOU CAN BE LOCKED OUT ON THE 2ND FL BALCONY. DOORS TO BALCONY TO REMAIN CHAINED & LOCKED UNTIL ISSUE IS RESOLVED. - ITEM #52 - EM CONTACT INFO FOR F/A 3.4 HR MIN SRI FEE & TCO FEE APPLIED Date: Inspector: Type: Status: 6/26/2012 Dennis Whitlock (DSW) 209 - FIRE FINAL 3 - REJECTED NOT TO CODE #2011044180 BARRY UNIVERSITY 11441 NW 2 AVE , Miami Shores 1. FIRE FINAL NOT APPRVD 2. CONTINUATION OF LT.HUNT S INSPECTION 6/22/2012 3. ITEMS COMPLETED FROM TENTATIVE LIST 6/22/12: # 2,# 3,# 5,# 7,# 8,# 9,# 11,# 21,# 23 ,#25,#26,#27,#29,#30,#31(STILL PENDING RM .247),#32,#33,#35,#37,#47 4. ALL OTHER ITEMS STILL PENDING Date: Inspector: Type: Status: 6/22/2012 Stephen Hunt (HU1507) 219 - FIRE - INSPECTION COMMENT 90 - FIRE - COMMENTS ONLY Barry University Dominican Hall June 15, 2012 11441 NW 2nd Ave. Permit 2011044180 3 Story Dormitory F/A 2012016084 Miami Shores Sprinklr 2011052787 A complete Life Safety was conducted in accordance with FFPC 2007. All previous Life Safety, fire alarm and sprinkler inspection reports have been satisfied or consolidated into this final report for TCO /CO. A TCO for occupancy is denied at this time. Approved water main extension plan was reviewed and fire hydrants were flowed and acceptable. 2 of 7 8/11/2012 9:37 AM http: / /bldgadmin miamidade. gov /MDFR/CommentRptPrint.asp ?Permit... This is a tentative list. All building construction shall be completed prior to Inspection for TCO. Do not occupy any parts of the building without a TCO or CO from the Fire Dept. and Building Official. Fees for this SRI inspection will be applied to this application. All fees shall be paid prior to obtaining a TCO. A Municipal TCO application with a Fire Department TCO status form (provided by Fire Inspector recommending TCO) shall be presented to the Fire Dept. Bureau OIC for consideration and approval prior to obtaining TCO. Date: Inspector: Type: Status: 6/22/2012 Stephen Hunt (HU1507) 219 - FIRE - INSPECTION COMMENT 90 - FIRE - COMMENTS ONLY Life Safety: 1. Provide signage with 2 in letters at gas boiler room indicating NATURAL GAS , NO SMOKING, FLAMMABLE. NFPA 1, 20, 54, 58. 2. All permitted penetrations into exit stair # 3 and main electrical room shall be fire stopped in accordance with NFPA 101:8- 3.5.1. 3. Provide approved tagged fire extinguishers throughout with maximum travel distance of 75 and 3000 sq. ft. throughout per NFPA 10. Exterior access rooms 135, 140, 142 and 146 shall be provided with an extinguisher. 4. Provide emergency lighting illuminated walking paths from all exit discharge locations to the public way in accordance with NFPA 101: 28.2.9.1, 101: 7.9. 5. Provide stairs constructed in accordance with NFPA 101: 7.2.2.3.6 at all exit stairs. The maximum riser height shall not exceed 7 in. The maximum variation of risers and treads shall comply with NFPA 101: 7.2.2.3.6. See uniformity requirements provided. The violation occurs at the risers where they meeting the stair intermediate and floor landings. NFPA 101: 7.2.2.3.6 Dimensional Uniformity. 7.2.2.3.6.1 Variation in excess of 4.8 mm (3- 16in.) in the depth of adjacent treads or in the height of adjacent risers shall be prohibited unless otherwise permitted in 7.2.2.3.6.3. 7.2.2.3.6.2 The tolerance between the largest and smallest riser or between the largest and smallest tread shall not exceed 9.5 mm (3 -8in.) in any flight. 6. All changes that effect Life Safety, Fire Alarm and Sprinkler System must be approved with plan revisions by the Fire Dept. for final permit approval. Date: Inspector: Type: Status: 6/22/2012 Stephen Hunt (HU1507) 219 - FIRE - INSPECTION COMMENT 90 - FIRE - COMMENTS ONLY 7. Provide fire rated stair enclosures in accordance with NFPA 101 - 7.1.3.2.1 (6) A -I. There shall be no penetrations into the stair enclosure other than those, which serve the stair for egress. Security penetrations, to include cameras and card access, in exits shall comply with Fire Dept. Policy or shall be removed from stairs 1, 2 and 3. See attached document. NFPA 101: 7.2.3.2.1, 7.1.9, 7.1.10. Air conditioning duct openings in exit stair # 3 shall be removed and the opening shall be closed with a listed 2 -hour fire rated assembly in accordance with NFPA 101: 8.3. 101: 7.2.3.2.1 (6) Penetrations into, and openings through, an exit enclosure assembly shall be limited to the following: (a) Doors permitted by 7.1.3.2.1(5) (b) *Electrical conduit serving the stairway (c) Required exit doors 3 of 7 8/11/2012 9:37 AM http: / /bl dgadmin. miamidade .gov /MDFR/CommentRptPrint. asp ?Permit... (d) Ductwork and equipment necessary for independent stair pressurization (e) Water or steam piping necessary for the heating or cooling of the exit enclosure (f) Sprinkler piping (g) Standpipes (h) Existing penetrations protected in accordance with 8.3.5 (i) Penetrations for fire alarm circuits, where the circuits are installed in metal conduit and the penetrations are protected in accordance with 8.3.5. 8. Provide approved signage at exit stair entries and all exit doors in accordance with NFPA 101:7.10.1.3. Exit tactile signage shall be located at each door into an exit stair enclosure and each exit door discharging from the building and such signage shall read as follows: EXIT. This sign shall be located on the latch side of door 60 in above the finished floor. 9. Provide restricted roof access to the public by installing a lock set door hardware on the inside of the roof access door and passage door hardware on the roof side of the door to reenter the stair. NFPA 101:7.2.1.5.3. There shall be signage at the roof door reading: ROOF ACCESS. 10. Provide mounted Supra Max elevator boxes mounted in elevator lobby for elevator. Mounting height shall be 5 ft-6 ft from finished floor. Provide all keys to operate each bank of elevator cars in its appropriate box in addition to an elevator machine room and roof access door key. Supra Max boxes are available by calling: 1- 800 - 547 -0252, Reference # 164144, Code # 6538. 11. Provide labeling of all fire and smoke barriers (exit enclosures and all fire rated walls) at top of wall in accordance with NFPA 101: 8.3.2.4. The wording, FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS or similar language shall be provided. This signage is required above concealed spaces and such signs shall be in 4 in letters, 1 half inch stroke and not more than 15? on center. This marking is required whenever a fire rated barrier is concealed. 12. Fire Department building access shall comply with NFPA 1: 18.2.2 and FD Policy. See attached Policy. Knox Box Model 3753 pad lock system required for west manual gate. Knox padlock 1800 - 552 -5669 x 1 for gates for Fire Dept. access. 13. Provide signage at west manual gate to read: FIRE DEPARTMENT EMERGENCY ACCESS GATE. The sign should be red with white letters. The letters should be large enough to be clearly legible from NW 2nd. Avenue. NFPA 1: 18, AHJ. 14. Provide light weight truss signage (Maltese cross) at building entry in accordance with FAC 69A- 060.0081. Law language document provided as attachment. 15. Complete installation of fire glass assemblies at main entry doors to room 132 for inspection. NFPA 101: 8, 80. 16. Provide panic door hardware at main electrical room in accordance with NFPA 70: 110.26 (C)(2). 17. Clarify occupant load for lounge /balcony rooms in accordance with NFPA 101. An occupant load sign is required and a 2nd exit door is required if occupant load exceeds 50. 18. Provide signage on all roof access panel doors to roof unsprinklered void spaces to read: NO STORAGE PERMITTED. NFPA 13, 101, AHJ. 19. Provide directional exit signage at the 1st floor landing of exit stairs 1 and 2 to direct occupants to the exit stair exit door. The door swinging in to the enclosure is not the exit door for the 2nd and 3rd floor occupants. NFPA 101: 7.10. Date: Inspector: Type: Status: 6/22/2012 Stephen Hunt (HU1507) 219 - FIRE - INSPECTION COMMENT 90 - FIRE - COMMENTS ONLY 20. Provide door coordination at 1st floor fire doors 115 and 116 double door assemblies that require coordination to close properly. A listed arrangement shall be provided to ensure the small door leaf is always closed first. The door astragal prevents the doors from working as a listed fire door assembly. NFPA 101, 80. 21. All handrails in exit stairs shall return to the wall or newel post in accordance with NFPA 101: 7.2.2.4.4.9. 22. Install 90- minute fire rated door at elevator machine room door in accordance with NFPA 101: 8.3 and the 4 of 8/11/2012 9:37 AM http: / /bldgadmin.miamidade. gov /MDFR/CommentRptPrint. asp ?Permit... approved plans. 23. Complete installation of 3 point door latching system at stair # 3 in accordance with NFPA 101: 7.2.1.8, NFPA 80. 24. Reposition all dorm room emergency evacuation signs to reflect the actual floor arrangement in accordance with NFPA 101: 28.7.4.1. 25. Correct wiring for single station smoke alarms to be interconnected in accordance with NFPA 72: 11.5.5.2 (A) 2. Locations to be corrected are in unit 314 (A and B) and unit 103 all detectors. 26. Replace defective smoke alarm battery in unit 335 lobby. NFPA 72: 11.6.4. 27. Relocate smoke alarms a minimum of 4 inch and a maximum of 12 inch from ceiling in accordance with NFPA 72: 11.8.3.4 in units 104, 204 and 304. 28. Provide continuous lighting at exit access corridors in accordance with NFPA 101: 7.8.1.2. Schedule inspection to test lighting sensors in exit access corridors in accordance with NFPA 101: 7.8.1.2.2. Automatic, motion sensor ?type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail -safe operation, the illumination timers are set for a minimum 15- minute duration, and the motion sensor is activated by any occupant movement in the area served by the lighting units. 29. Provide 45 minute fire rated doors all janitors closets as show on the approved plans. NFPA 101: 8, 80. 30. Provide NO STORAGE signage at all electrical rooms in accordance with NFPA 1, 70: 110.26 (B). 31. Replace missing ? hour fire label at door 347A for inspection. NFPA 101: 8, 80. 32. Correct orientation of exit signs on all floors in exit corridors at intersections as explained by Fire Inspector and NFPA 101: 7.10. Signs need to be turned 180 degree and the chevron removed to direct occupants to exits. Also the exit signs at floors 2 and 1 that are next to a sleeping unit and food service area shall be double sided and provided with a chevron to direct occupants to exit stair. 33. Adjust trash chute and wash down fire rated doors to close and latch at floors 2 and 3 in accordance with NFPA 101: 8.3 and NFPA 82. 34. Provide unrestricted exit access from Lounge balcony 200A to interior of building in accordance with NFPA 101: 7.2.1.5.1 101: 28.2.2.2.2.1. 35. Provide exit sign at door 200 Lounge in accordance with NFPA 101: 7.10. There are 2 doors leading from this room. 36. Fire Inspector to review approved site plan at re- inspection to verify compliance with Fire Dept. site access and apparatus clearances. NFPA 1. 37. Clarify and provide door cut sheets on double doors at rooms 200 and 300 where the vertical gap appears excessive and astragal may be required for the assembly. NFPA 101, 80. 38. Provide installation of an approved fire stop system at room 117 fire rated wall. NFPA 101: 8.3. 39. Provide exit sign at 2nd egress door in Multi- purpose room 152 in accordance with NFPA 101: 7.10. 40. Provide occupant load sign posted at the main entry to the Multi- purpose room 15in accordance with NFPA 101:12.7.9.3.1. 41. Provide an electrical disconnect accessible to the Fire Department in accordance with NFPA 1: 11.1.7.1. NFPA 1 Building Disconnect Access. 1: 11.1.7.1* Means shall be provided for the fire department to disconnect the electrical service to a building, structure, or facility when the electrical installation is covered under the scope of NFPA 70. NFPA 1: 11.1.7.2 The disconnecting means shall be maintained accessible to the fire department. 42. Repair trash chute assembly guillotine to close completely when fusible link is activated in accordance with NFPA 101:8 and NFPA 82. 43. Provide emergency lighting or repair emergency lighting in the following locations in accordance with NFPA 101: 28.2.9.1 and the approved plans. a. Room 200A balcony (an additional E/M fixture in Lounge 200 may achieve illumination), b. Trash rooms at floors 1, 2 and 3, c. Study room 236 (inoperative), d. Men ?s restroom 1st floor (inoperative), e. Room 140 pump room, f. Room 142 Water tank, g. Room 146 Electrical room, 5 of 7 8/11/2012 9:37 AM http: // bldgadmin. miamidade. gov /MDFR/CommentRptPrint.asp ?Permit... Date: Inspector: Type: Status: 6/22/2012 Stephen Hunt (HU1507) 219 - FIRE - INSPECTION COMMENT 90 - FIRE - COMMENTS ONLY Fire Alarm: 44. Clarify location of carbon monoxide detection required by FSS 553.885. Carbon monoxide detection is required where there are rooms used for sleeping purposes. 45. Provide tamper screws at outside J -box wiring to back flow and PIV. NFPA 72, AHJ. (See attachment of Florida State Statute). 46. Provide fire alarm signaling occupant notification on the roof mechanical equipment area in accordance with NFPA 101: 9.6.3.6.1. 47. Provide electrical breaker dedicated circuits identified with a red marking, FIRE ALARM CIRCUIT, NFPA 72:4.4.1.4.2.2. Electrical panel and circuit numbers shall be indicated at FACP and at all PBS units. 48. Relocate speaker strobe currently installed on wall blocked by washing machines in Laundry area in accordance with NFPA 101: 9.6.3.5 and 72: 7.5. 49. Relocate system smoke detector by restroom in unit 133 a minimum of 36? from all air conditioning return grills and shower room in accordance with NFPA 72: 5.7.3. 50. Provide system smoke detectors installed within 5? from all doors equipped with door hold open devices at floor 1 lobby area in accordance with NFPA 101: 7.2.1.8.2 (3 and 5). These doors shall have smoke detectors installed in accordance with NFPA 72: 5.14.6. 51. Provide exterior mounted sign at main electrical room to read: FIRE ALARM CONTROL PANEL. The sign should be red with white letters. NFPA 1, 72, AHJ. 52. Provide emergency contact name, address and phone number posted at the main entrance in accordance with CO. ORD. 88-46 sec 1 (4). 53. Provide system certification of completion in log book in accordance with NFPA 72 and FAC 69A -48. 54. Provide approved revised fire alarm plans show all deviations from the original approved plans. NFPA 1. Sprinkler: 55. Provide additional signage to identify STANDPIPE / AUTO SPRINKLER at FDC in accordance with NFPA 14 for combination systems and where a manual standpipe system is provided, each hose connection shall be provided with a conspicuous sign that reads ?MANUAL STANDPIPE FOR FIRE DEPARTMENT USE ONLY. This signage shall be provided at the FDC and at each standpipe hose valve connection. 56. Provide lock and chain on PIV and all backflow preventor control valves. All 3 control valves at the backflow can be chained together using 1 lock and chain. NFPA 13, FDP. 57. Inspector to research why there is no standpipe installed in exit stair # 3 as required by NFPA 14: 7.4. (NFPA 14: 7.4. Number of Standpipes. Separate standpipes shall be provided in each required exit stairway). 58. Relocate sprinkler head in room 154 to be positioned above duct work in accordance with NFPA 13. Currently the sprinkler head is installed between 2 duct assemblies. Tentative list. Do not occupy without TCO or CO. SRI fee will be applied to the application number for this inspection. Stephen Hunt, Lieutenant Miami -Dade Fire Rescue Department www.miamidade.gov "Delivering Excellence Every Day" 6 of 7 8/11/2012 9:37 AM http: / /bldgadmin. miamidade .gov /MDFR/CommentRptPrint.asp ?Permit... Date: Inspector: Type: Status: 6/15/2012 Tumaini Jabali (JABALIT) 209 - FIRE FINAL 3 - REJECTED NOT TO CODE PERMIT 2011044180 11441 NW 2ND AVE. BARRY UNIVERSITY DORMS 1. FIRE FINAL NOT APPROVED. 2. ITEMS 2 AND 4 FROM LT. POUGH S LIST HAVE BEEN COMPLETED 3. ITEMS FROM LT. POUGH S LIST THAT ARE STILL PENDING. ADJUST DOORS 119,220,320 AND 317 TO CLOSE AND LATCH 4. ITEMS 6 AND 7 STILL PENDING. NO OTHER ITEMS CHECKED AT THIS TIME. Date: Inspector: Type: Status: 6/13/2012 Casandra Pough (POUGHC) 209 - FIRE FINAL 3 - REJECTED NOT TO CODE 6/13/12 TENATIVE LIST POUGH PERMIT# 2011044180 1. FINAL FIRE INSPECTION NOT APPROVED. 2. FAILURE OF INTERIOR BLDG. CLEAR OF DEBRIS, WASTE, CONSTRUCTION EQUIPMENT, ETC. NFPA 1.19.2.1.3 PROVIDE /MOUNT COUNTY CERTIFICATION PAPERS TO OPERATE ELEVATORS. 3. PROVIDE THE PROOF THAT THE F/A AND SPRINKLER INSPECTIONS ARE APPROVED. 4. PROVIDE THE ELEVATOR SUPRA MAX LOCK BOX AND MOUNT IN THE MAIN LOBBY. 5. ADJUST DOORS TO SELF LATCH FOR FINAL.(DOORS# 119, 133, 135, 153, 150, 155, WOMEN/ MENS BATHROOM DOORS 1ST FLOOR, SOUTH SIDE MULTIPURPOSE ROOM EXTERIOR DOOR 1ST FLOOR, 151, 241,242,239, 247, 234, 231, 222, 201, 202,203, 218, 220, 206, 211, 213, 320, 317. 6. RM# 132 MAIN OFFICE FIRE RATED GLASS INSTALLATION, STAIR#3 DOOR NOT SELF LATCHING, 3RD FLOOR STAIR DOOR( NORTHSIDE) NOT LATCHING, 7. SEAL AROUND OPEN PENETRATION ON STAIR LANDING (NW STAIR)AND AROUND THE SPRINKLER PIPING INSIDE STAIR #3. 8. STILL NEED EM LIGHTING TESTING, EXIT SIGNAGE PLACEMENT, EXTERIOR SITE PLAN /LANDSCAPING AREA AS PER PLANS, HANDRAIL GUARD RAILS THROUGHOUT THE STAIRS, VERIFY FIRE RATING ABOVE CEILING TILES INSIDE CORRIDOR AREAS ON ALL FLOORS. 9. FIRE EXTINGUISHER, 2ND FLOOR EXTERIOR BALCONY VERIFIED OKAY. 7 of 7 8/11/2012 9:37 AM ti ❑ O — In Kimley -Hom and Associates, Inc. August 6, 2012 Mr. Norman Bruhn Village of Miami Shores Building Department 10050 Northeast 2nd Avenue Miami Shores, Florida 33138 Re: Barry University Housing KHA Project Number: 144554000 Final Certification Dear Mr. Bruhn: • 1690 S. Congress Avenue Suite 100 Delray Beach, Florida 33445 We have been retained by Barry University to provide design, permitting and construction phase assistance for the improvements associated with the Barry University Housing Project to construct Dominican Hall. Based on Kimley -Horn and Associates, Inc. periodic site observations, I hereby certify that the proposed improvements have been installed in substantial conformance with the plans and specifications approved by the Village of Miami Shores and affix my seal this 6th day of August 2012. alit ?;4 *r.Y�e's KIM1.i) -IORN rAS>hTES, INC. Michael 1'1 FL P.E. No.' � 11 \\O Senior Project Manager Site Observation Reports are attached for your reference. Please contact us at (561) 330 -2345 should you require additional information. • TEL 561 330 2345 FAX 561 330 2245 Kimley -Horn and Associates, Inc. CONSTRUCTION SITE VISIT REPORT DATE PROJECT OWNER GEN CONTRACTOR SUB CONTRACTOR WEATHER 6/21/11 Barry University Student Housing Barry University Moss and Associates American Engineering Partly cloudy / 80° ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 KHA PROJ. No. 0406880001 LOCATION ENG PROJECT REP GC PROJECT REP Miami Shores Village, FL Elka Linton - Dorsett Sherry Werner PRESENT AT SITE Ricky Culpepper Contractor in process of installing storm drainage structure S -10. The structure was set in place and surveyed. HDPE drainage pipe has been installed between S -10 and the previously installed S -8 and the connections were grouted. Top slab, frame /grate have not yet been installed. Based upon the information presented, the installation of drainage structure S -10 and associated storm drainage system appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 3 Kimley -Horn and Associates, Inc. • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Catch Basin S -8 was previously set in place. Trench box is installed to provide temporary shoring for the installation of the HDPE the pipe that will connect drainage structure S -8 to S -10. HDPE pipe is bedded and installed inside trench box north of drainage structure S -8. • TEL 305.673.2025 FAX 305.535.7760 Page 2 of 3 111.7111MI 1 and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Contractor grouting the pipe connection to south side of drainage structure S -10. Drainage pipe between drainage structures S -8 and S -10 inside trench box. ■ TEL 305.673.2025 FAX 305.535.7760 Page 3 of 3 riKimley -Horn and Associates, Inc. SEWER LEAKAGE AND LAMPING TEST REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER 6/28/2012 Barry University - Chillers Barry University GEN CONTRACTOR Moss and Associates WEATHER Partly cloudy / 89° KHA PROJ. No. LOCATION ENG PROJECT RFP GC PROJECT REP 0406880001 Miami Shores Village, FL Matt Gibson Rich Archer MENT Site visit was conducted to perform sanitary sewer leakage and tamping tests for 375 LF of 8" gravity sanitary sewer main and two (2) sanitary sewer manholes (MH -1 and MH -2) installed per FDEP Permit No. 253651 - 310 -DWC and DERM Permit No. 2011 -SEW- EXT- 00061. The contractor filled the gravity system (from manhole to manhole) with water to the rim of the installed manholes. The water level was observed for two (2) hours. No drop in water level was observed during the stated timeframe. After, a tamping test was performed. No pipe deflections were observed. Pictures of manhole (MH -2) at the beginning and end of leakage test are shown below. C( NCLUSION Based upon the Engineer's observations, it was determined that the installed sanitary sewer system passed both the tamping and the leakage test. • TEL 305.673.2025 FAX 305.535.7760 Page 1 of 2 pr Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Water level measured at Manhole (MH -2) at the beginning of the leakage test. Water level measured at Manhole (MH -2) after two (2) hours. ■ TEL 305.673.2025 FAX 305.535.7760 Page 2 of 2 ® ® Kimley -Horn 1 and Associates, Inc. CONSTRUCTION SITE VISIT REPORT DATE PROJECT OWNER GEN CONTRACTOR SUB CONTRACTOR WEATHER 6/25/11 Barry University Student Housing Barry University Moss and Associates American Engineering Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 0406880001 Miami Shores Village, FL Elka Linton - Dorsett Sherry Wemer Ricky Culpepper Contractor in process of installing storm drainage structures S -7 and S -8. Both structures were set in place and surveyed. HDPE drainage pipe has been installed between the two drainage structures, connected and grouted. French drain has been installed between the two structures, including perforated HDPE, ballast rock and filter fabric. Neither structure has top slab or frame /grate vet. CONCLUSION Based upon the information presented, the installation of drainage structures S -7 and S -8 and associated storm drainage system appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 4 1.7.1.1r1 Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Drainage structure S -7 being lowered into place. Temporary shoring was provided during installation. French drain system being installed using trench box to shore the trench and maintain the required depth and width of the French drain. Perforated HDPE pipe, ballast rock and filter fabric are installed adjacent to structure S -7. ■ TEL 305.673.2025 FAX 305.535.7760 Page 2 of 4 •Kimley -Horn ® 1 and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 HDPE pipe connection to S -7 is grouted. 411111 t Trench box is in place for installation of French drain adjacent to one side of drainage structure S -8. HDPE pipe connection to opposite side of S -8 is already installed and grouted. ■ TEL 305.673.2025 FAX 305.535.7760 Page 3 of 4 a 1Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Installation of French drain and HDPE pipe underway adjacent to drainage structure S -8. .,ii'. yet Completed French drain system has been wrapped with filter fabric and is ready for backfill. ■ TEL 305.673.2025 FAX 305.535.7760 Page 4 of 4 ®im ni Kimley -Horn and Associates, Inc. SUBSTANTIAL COMPLETION WALK THROUGH REPORT #2 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 7/23/2012 Barry University Student Housing — Phase 2 Barry University Moss and Associates Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT DCD GC PROJECT REP 0406880001 Miami Shores Village, FL Matthew Gibson, PE Jason Ramunno The site walkthrough occurred on July 23, 2012 with Jason Ramunno. This was the second walkthroughs to look final lift of paving and striping (excluding thermoplastic). Work associated with the HVAC System Revisions for Benincasa and Kolasa Halls project is not included in this list, and will be handled separately. Based upon our observations during this site visit, it appears that work completed to date is in substantial conformance with the approved civil plans and specifications, with the following exceptions. Item numbers below are marked on included site plan for reference. 1) Striping in parking stall. 2) Ponding just south of Structure 8 and just north of Structure 7. 3) Uneven seam north of Structure 7 4) Raveling / loose aggregate near east end of crosswalk 5) Raveling / loose aggregate near curb of south HC stall and north HC stall 6) Raveling / loose aggregate north of sewer manhole around 4th stall / curb island. Photos corresponding to these items follow. • TEL 305.673.2025 FAX 305.535.7760 Page 1 of 5 ©— Kimley -Horn ® and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS PHOTO 1 — Parking stall striping PHOTO 2 — Ponding (not included) PHOTO 3a — Asphalt Seam ■ TEL 305.673.2025 FAX 305.535.7760 Page 2 of 5 PPP-11M /1 Kimley -Horn and Associates, Inc. PHOTO 3b — Asphalt Seam • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 4 — Ravelings / Loose aggregate near crosswalk IN TEL 305.673.2025 FAX 305.535.7760 Page 3 of 5 pr-i r' Kimley -Horn ® and Associates, Inc. PHOTO 5a — Ravelin • / Loose a • • re • ate near south HC Stall ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 5b — Raveling / Loose aggregate near north HC Stall • TEL 305.673.2025 FAX 305.535.7760 Page 4 of 5 IN Kim ley-Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 6 — Raveling / Loose aggregate north of sewer MH near curb island ■ TEL 305.673.2025 FAX 305.535.7760 Page 5 of 5 — —RAN: ��.__'-- - ".... :«....,.._._.. ,. ) NW 115th STREET MD MP.. °i7 J lsir .1.2. MD i. j....�. 14 • SO WASP PEES LEGEND: - - - - WOES UK OF�6P66aF. n D66 PRoPOso MSC.) 010111, MM.-ma FRFIva• Rs, saw Rory opsara PRO, PIPPLIMP WTI COSCRSIO ROCOCO 300/RANIRO AKA (SIX LOOSPAPE F66 664 OI' Mop. DANRAW: 61WI0N6 MO, latiLla11011 Md. PSINALS MDR MP PPO.COT 1.1a19 o' mmovn oawna / /CC C MASCO IM MO uav4ml EL. i Tai BASIN CATCH BASIN OR POA RV. EWL�, USF 4105 FRAME - 6220 CRATE INV. 5 DO) VI CED CATCH BASIN UST 4106 MAME - 6220 CRATE RIM E4. =11.70' Nv. EL- 7.50'(5) INV. EL.- 7.50'(5) CATCH BASK+ OSP 3 -124 i1PE "0" (4' -0'0) R APPROV. EWAL USF 4105 FRAME - 6220 CRATE RIM EL 11.65' 1400. - 7.50' (W) L CATCH BA uv 3 -124 TYPE b" OR ARMS.. EWAL USF 04 El. 5 11.75 - 6220 CRATE 7.50. (0) NV L . E - 5.75' (W) DAPPLE (0) CATCH BARN us? 3-10.5 OR A 0405 1 M EQUAL - .ATE RIM 4L AME -8120 11.90' NV.0.- 275(5) NV. 0. a 275' (W) BYRE ([ ) CATCH BARN CATCH BARN USP USP 3-18.5 EQUAL "D' (S -0'e) CR PR24 EQUAL "D (4' -50) A PROF. EQUAL OV. EQUAL OR L 200. - 6230 CRATE �__�_ -._ 6220 CRATE Nn -12W w.E- 5.75'(N) 673' (E) BAFFLE (H. E) ADS GRAM BASIN IS "P 5" STANDARD N -20 ORATE V. .4040 (S) OOS ORAN BARN 15-4 15" STANDARD N -20 ORATE v��ca- 1D.D5'(w .y ns (sE) • CATCH BARN CATCH BARN CATCH BASIN OAR 3-15.4 TYPE "0' (4' -0'0) USP 5 -3010" TVPE P -10 (42 " -0 "e) USP 3 -36.0" TYPE P -10 (42" -0"0) R APPROV. EWA L CR APPROV. EQUAL UST' MARE - 6220 (MUTE 0- - L , A50- 50. 60' 0. - OSO' Nv. EL - 765' (5) RAFFLE (S) BAF0.0 (N) Barry University Residence Hall v96 1,6432,68711 POSCSOF.PRIR CAWWOrDESIGN aat PR SAO 6...oin 122 DNA, AARANA NO it PAVING GRADING AND DRAINAGE PLAN C -300 ®Kimley -Horn ® I 1 and Associates, Inc. SUBSTANTIAL COMPLETION WALK THROUGH REPORT #1 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 6/19/2012 Barry University Student Housing — Phase 2 Barry University Moss and Associates Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT 000 GC PROJECT REP 0406880001 Miami Shores Village, FL Matthew Gibson, PE Jason Ramunno The site walkthrough occurred on June 19, 2012 with Jason Ramunno. This was the first of two walkthroughs to look at everything but final lift of paving and general clean up relating to the Dominican Hall project. Work associated with the HVAC System Revisions for Benincasa and Kolasa Halls project is not included in this list, and will be handled separately. Based upon our observations during this site visit, it appears that work completed to date is in substantial conformance with the approved civil plans and specifications, with the following exceptions: 1) The following flags of concrete sidewalk were cracked and /or damaged, and need replacing a. 7th flag north of the west entrance to Dominican Hall. b. 3`d flag north of light bollard in south yard c. Landing outside of southern door on west face of building (hole in slab) 2) Parking lot base and asphalt repair near crosswalk between Dominican and Benincasa Halls 3) Remove temporary water service from north side of property 4) Install handrails at northwest Benincasa entrance 5) Clean utility paint markings and wheel scuffs off of concrete curbs, sidewalks (throughout site) Photos corresponding to these items follow. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 4 ® ®� Kimley -Horn ® and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS PHOTO la PHOTO 1 b ■ TEL 305.6732025 FAX 305.535.7760 Page 2 of 4 ® ®� Kimley -Horn and Associates, Inc. PHOTO 1c ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 2 ■ TEL 305.673.2025 FAX 305.535.7760 Page 3of4 ❑ ®/� Kimley -Horn 1 and Associates, Inc. PHOTO 3 • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 4 ■ TEL 305.6732025 FAX 305.535.7760 Page 4of4 ®O in Kim ley-Horn and Associates, Inc. CONSTRUCTION SITE VISIT REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 6/08/12 Barry University Student Housing Barry University Moss and Associates Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Wemer Rich Archer Photos 1-4: Installation of GrassPave units, flush curb and fence gate at fire department access (NW corner of site). Based upon the work observed, the installation of the curb and GrassPave units appear to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. • TEL 305.673.2025 FAX 305.535.7760 Page 1 of 1 - FlKimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS TEL 305.673.2025 FAX 305.535.7760 Page 2 of 2 ❑ Kimley -Horn 1 and Associates, Inc. TEL 305.673.2025 FAX 305.535.7760 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 Photo #4 Page 3 of 3 ® ®/'� Kimley -Horn 1 and Associates, Inc. CONSTRUCTION SITE VISIT REPORT • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 5/24/12 Barry University Student Housing Barry University Moss and Associates Rainy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Wemer Rich Archer Photos 1-4: Sidewalks installed throughout south yard. Photo 5: Dumpster enclosure in progress. Photo 6: Erosion control measures in place on new drainage inlet structure S -12. rNCLUSI Based upon the work observed, the installation of the proposed sidewalks, dumpster pad and enclosure, and erosion control measures appear to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 1 ®— Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS i➢ ii ii ii ii i� Ni ii Photo #1 • TEL 305.673.2025 FAX 305.535.7760 Page 2 of 2 ®� in Kim ley-Horn ® and Associates, Inc. ■ TEL 305.673.2025 FAX 305.535.7760 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 Photo #4 Page 3 of 3 Ella" Kimley -Horn and Associates, Inc. • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 • TEL 305.673.2025 FAX 305.535.7760 Page 4 of 4 ® ®� Kimley -Horn ® and Associates, Inc. CONSTRUCTION SITE VISIT REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 5/1/12 Barry University Student Housing Barry University Moss and Associates Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Werner Rich Archer Photos 1-8: Type D' curb installed throughout parking areas. Rough grading and preparation for sidewalks in south yard was in progress (not photographed) Based upon the work observed, the installation of the proposed curb appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 5 1117 VIKimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Photo #1 Photo #2 • TEL 305.673.2025 FAX 305.535.7760 Page 2 of 5 ©� Kimley -Hom and Associates, Inc. ■ TEL 305.673.2025 FAX 305.535.7760 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 Photo #4 Page 3 of 5 In Fri Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #5 Photo #6 • TEL 305.673.2025 FAX 305.535.7760 Page 4 of 5 ®_ v1 Kim ley-Horn and Associates, Inc. • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #7 Photo #8 • TEL 305.673.2025 FAX 305.535.7760 Page 5of5 ®NM Kimley -Horn 1 and Associates, Inc. CONSTRUCTION SITE VISIT REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT 3/23/12 Barry University Student Housing OWNER Barry University GEN CONTRACTOR Moss and Associates WEATHER Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Werner Rich Archer Photo 1 -3: 6" Concrete installed for steps, sidewalks, and paver header bands at Benincasa northwest entrance. Based upon the work observed, the installation of the proposed concrete work appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 3 Fri Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Photo #1 Photo #2 ■ TEL 305.673.2025 FAX 305.535.7760 Page 2 of 3 vl Kimley -Horn ® and Associates, Inc. 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 ■ TEL 305.673.2025 FAX 305.535.7760 Page 3 of 3 ® ®� Kimley -Horn and Associates, Inc. CONSTRUCTION SITE VISIT REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR WEATHER 4/26/12 Barry University Student Housing Barry University Moss and Associates Sunny / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE Photo 1 -2: First lift of asphalt installed, trenches for curb excavated. Photo 3: Pavers for drop -off area at Dominican installed. 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Wemer Rich Archer CONCLUSION'' Based upon the work observed, the installation of the proposed work appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. TEL 305.673.2025 FAX 305.535.7760 Page 1 of 1 P7= Kimley -Horn NE 1 and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Photo #1 Photo #2 • TEL 305.673.2025 FAX 305.535.7760 Page 2of2 prrimni Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 • TEL 305.673.2025 FAX 305.535.7760 Page 3 of 3 P7 111M1/11 Kimley -Horn ® and Associates, Inc. CONSTRUCTION SITE VISIT REPORT DATE PROJECT OWNER GEN CONTRACTOR WEATHER 4/10/12 Barry University Student Housing Barry University Moss and Associates Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Werner Rich Archer Photo 1 -2: Concrete formwork installed for southeast patio and Dominican valet drop off area. Based upon the work observed, the installation of the proposed concrete work appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. TEL 305.673.2025 FAX 305.535.7760 Page 1 of 1 ®— Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 • TEL 305.673.2025 FAX 305.535.7760 PHOTOGRAPHS Photo #1 Page 2 of 2 ®� Kimley -Horn and Associates, Inc. ■ TEL 305.673.2025 FAX 305.535.7760 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #2 Page3of3 ® ®/`i Kimley -Horn ® 1 and Associates, Inc. CONSTRUCTION SITE VISIT REPORT DATE PROJECT 1/11/12 Barry University Student Housing OWNER Barry University GEN CONTRACTOR Moss and Associates WEATHER Partly cloudy / 80° KHA PROJ. No. LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 0406880001 Miami Shores Village, FL Matthew Gibson Sherry Wemer Charlie Arndall Photo 1: 6" D.D.C.V (left) and 4" B.F.P. (right) installed and piping runs from each into building Photo 2: Piping from D.D.C.V. and B.F.P. into proposed building. Photo 3: Rainwater leaders tied into building connection and proposed storm pipe (near manhole S -11). Photo 4: Connection to building rainwater leader. 6" minimum separation between storm pipe and site lighting /irrigation conduits (not at time of photo). Photo 5: 3" condensate piping tied into building and proposed storm manhole ONCLUSI Based upon the information presented and work observed, the installation of the proposed work appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all project components within the scope and responsibility of the Civil Engineer for this project. • TEL 305.673.2025 FAX 305.535.7760 Page 1 of 1 ® ® � Kimley -Horn and Associates, Inc. i 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTOGRAPHS Photo #1 Photo #2 • TEL 305.673.2025 FAX 305.535.7760 Page 2 of 2 ® Kimley -Horn 1 and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #3 Photo #4 ■ TEL 305.673.2025 FAX 305.535.7760 Page 3 of 3 pori Kimley -Horn ® 1 and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 Photo #5 ■ TEL 305.673.2025 FAX 305.535.7760 Page 4 of 4 pr Kimley -Horn �.j and Associates, Inc. CONSTRUCTION SITE VISIT REPORT ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 DATE PROJECT OWNER GEN CONTRACTOR SUB CONTRACTOR WEATHER 6/27/11 Barry University Student Housing Barry University Moss and Associates American Engineering Partly cloudy / 80° KHA PROJ. No. 0406880001 LOCATION ENG PROJECT REP GC PROJECT REP PRESENT AT SITE Miami Shores Village, FL Elka Linton - Dorsett Sherry Wemer Ricky Culpepper COMMENTS .' Contractor in process of installing storm drainage structures S -1 and S -2. Both structures were set in place and surveyed. HDPE drainage pipe has been installed between the two drainage structures, connected and grouted. French drain has been installed between the two structures, including perforated HDPE ballast rock and filter fabric. Structure S -1 has top slab, inlet frame /grate installed. Structure S -2 has no top slab or frame. Pollutant retardant baffles have not yet been installed on any structure. NCLUSION Based upon the information presented, the installation of storm drainage structures S -1 and S -2, including associated piping and French drain system, appears to be proceeding in substantial conformance with the approved civil plans and specifications. Upon completion of the project, the Civil Engineer of Record will issue a signed and sealed certification of completion for all Project components within the scope and responsibility of the Civil Engineer for this project. ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 3 ®� VI Kim ley-Horn ® and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 ■ TEL 305.673.2025 FAX 305.535.7760 PHOTOGRAPHS 3^` 4 Catch Basin S -1 has been set in place. Location and elevation is being surveyed and checked for proper alignment. 1 1111 1 III Drainage structure S -1 in background. Contractor is in process of wrapping French drain with filter fabric. Page2of3 ®®� Kimley -Horn and Associates, Inc. ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 HDPE pipe grouted to S -2 catch basin. Excavation is being temporarily shored with trench box. Drainage structure S -1 is in place but no baffles, top slab or frame /grate have been installed. HDPE drainage pipe has been connected and grouted to structure wall. French drain has been excavated, wrapped in filter fabric and filled with ballast rock. ■ TEL 305.6732025 FAX 305.535.7760 Page 3 of 3 In Kimley -Horn ■ I 1 and Associates, Inc. DATE PROJECT OWNER GEN CONTRACTOR SUB CONTRACTOR WEATHER CONSTRUCTION SITE VISIT REPORT 8/22/11 Barry University Student Housing — Phase 1 Barry University Moss and Associates American Engineering Partly cloudy / 80° Present during the site visit were the following: ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 KHA PROJ. No. LOCATION ENG PROJECT DCD GC PROJECT REP PRESENT AT SITE 0406880001 Miami Shores Village, FL Elka Linton - Dorsett Sherry Werner See list in "Comments" From Barry University: Dr. Michael Griffin, David Mace, Monica Soto Jeffrey Yao From Moss: Sherry Werner, Tom Larabell, Charlie Amdall From EDSA: Kona Gray, Mihaela Zaharescu From Kimlev -Horn: Juan Jimenez, Matt Gibson From Valley Crest: Jose Santiago Other subconsultants The site visit with the above personnel took place on 8/22/11 from about 10:OOAM — 11:30AM. The group walked Phase I to observe completed work to date on the parking and landscape areas, pedestrian walkways and access to the building. Below in "Conclusion" is a listing of our findings referencing attached photos. Based upon our observations during this site visit, it appears that work completed to date is in substantial conformance with the approved civil plans and specifications, with the following exceptions: 1) Approximately three drainage structures did not have the pollutant retardant baffles (PRBs) installed yet. Interiors of drainage structures not inspected due to no one available to flip open rims /grates. KHA to conduct another site visit (to be scheduled by Moss) to view those after PRBs are installed. 2) The handicap pavement symbol in the new handicap stalls is smaller than the 5' symbol specified on the plans. Needs to be discussed with Miami Shores Village (see Photo 1 attached). 3) There were about three areas where ponding was observed on the new asphalt. These are to be corrected by re- heating and rolling the asphalt (see Photos 2 and 3 attached). 4) The new standard parking stall at the NE comer of the parking lot was measured at 6 feet wide, which is not in accordance with the plans. This issue is to be discussed with the University and Miami Shores Village to see if this parking stall can be striped out and eliminated (see Photo 4 attached). 5) The temporary sidewalk north of the Benincasa Hall main entrance exceeds 5% longitudinal slope in some areas. This will require replacement of approximately three new sidewalk flags. Also, the sod around this new sidewalk was placed on top of existing fill and sits too high. Sod needs to be reset so it is flush with the concrete walk/curb (see Photo 5 attached). 6) Thermoplastic pavement markings (other than parking stalls) need to be installed toward end of September (30 days after final lift of asphalt) (see Photo 6 attached). ■ TEL 305.673.2025 FAX 305.535.7760 Page 1 of 4 ® ®/l Kimley -Horn [_1 and Associates, Inc. • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO PHOTO 1 PHOTO 2 • TEL 305.673.2025 FAX 305.535.7760 Page 2 of 4 Kimley -Horn and Associates, Inc. PHOTO 3 ■ 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 4 ■ TEL 305.673.2025 FAX 305.535.7760 Page 3 of 4 r.L_1Kimley -Horn and Associates, Inc. PHOTO 5 • 1221 Brickell Avenue, Suite 400 Miami, Florida 33131 PHOTO 6 ■ TEL 305.673.2025 FAX 305.535.7760 Page 4of4