Loading...
Barry University Residence Hall Fire Stopping Detail• Barry University Residence Hall Fire Stopping Details 1. Pumbing a. Fire Stopping b.Hilti Sleeve Inserts 2. Mechanical • 3. Electrical 4. Fire Sprinkler • CANVONDESIGN • • SUBMITTAL IDENTIFICATION SHEET To be completed by Contractor /CM Project Name /Address/Number Barry University Residence Hall 11300 NE 2nd Ave Miami Shores, FL 33161 Cannon Design Project No. 03617.00 Owner Barry University Architect / Engineer Cannon Design Submitted By Moss Contractor! CM Submittal No. Cannon Design Submittal No. 000042 Drawing / Detail Reference M0001 Manufacturer / Supplier Hilti Priority. ❑ Critical Specification Section/ Paragraph 07 8413 - Penetration Fire Item / Product ID Required Date: December 12, 2011 Remarks or Deviations Contractor 1 CM Certification (submittals not certified will be returned without review) J. Ramunno December 12, 2011 Reviewed by To be completed by Reviewer Cannon Design Submittal Number and Received Date Requirements for Submission to Cannon Design Shop Drawings: Product Data: Samples: It A. No Exceptions Taken No further review of submittal is required. ❑ B. Make Correction Noted Incorporate corrections in work; resubmission is not required unless otherwise noted. ❑ C. Revise and Resubmit Revise as noted, and resubmit for further review. ❑ D. Rejected Submittal not in compliance with Contract Documents. ❑ E. For Record Only Received for record purposes only. Review is for conformance with the design concept of this project and for general compliance with contract documents. Contractor is responsible for quantities, dimensions and compliance with contract documents and for information that pertains to fabrication processes, construction techniques and coordination of this work with all trades which will be affected thereby. This review is null and void if submittal deviates from contract documents and does not indicate or note deviations. AIE Comments AL FA STDPpi v D - rA1/__5 ACC.E PIA 6u,e Rod as E. s 1� Date Reviewed by Date 08/08 Plumbing DH ENGINEERING JUDGMENT FIRESTOP DETAIL PROJECT : BARRY UNIVERSITY RESIDENCE HALL CONTRACTOR : RIGHT WAY PLUMBING FRONT VIEW F- RATING =1 -HR. OR 2 -HR. SECTION A -A A 1. GYPSUM WALL ASSEMBLY (UL CLASSIFIED U400 SERIES WALL) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). . STEEL STUDS TO BE MINIMUM 2-1/2" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING AND INSTALLED AT AN ANGLE NOT GREATER THAN 45° FROM PERPENDICULAR : A. MAXIMUM 4" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 4" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 4" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 4. MAXIMUM 5-1/4" NOMINAL DIAMETER SHEET METAL SLEEVE (MIN. 28 GA.) HAVING A MINIMUM 1" LAP ALONG LONGITUDINAL SEAM. LENGTH OF SLEEVE TO EXTEND 2" BEYOND EACH SURFACE OF WALL. 5. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1-3/4" WIDE) CONTINUOUSLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, COVERING TWO TIMES, AND HELD IN PLACE WITH TAPE, WRAP STRIP IS INSTALLED FLUSH WITH ENDS OF SHEET METAL SLEEVE. 6. HILTI COLLAR CLAMP(S) FASTENED AROUND SHEET METAL SLEEVE AT THE CENTER OF EACH WRAP STRIP. 7. MINIMUM 5/8" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 8. MINIMUM 112" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 6 ". 2. ANNULAR SPACE BETWEEN SLEEVE AND PERIPHERY OF OPENING = MIN. 0 ", MAX. 3/4". 3. CLOSED OR VENTED PIPING SYSTEM (PVC & ABS = SCHEDULE 40; CPVC = SDR 13.5). THIS ENGINEERING JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXPECTED TO PASS THE STATED RATINGS IF TESTED. (REFERENCE : UL SYSTEM NO. W -L -2340) Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Designed by Sheet Scale Date 1 of 1 118 " =1" Apr. 18, 2012 Drawing No. 156389a Saving Lives through Innovation and Education Hilti Firestop Systems Firestop Submittal Package Right Way Plumbing Project: Barry University Residence Hall N. Miami Ave N. Miami, FL • Date: 2011 -11 -29 Submitted by: brian campbell 160 nw 16 st boca raton , FL 33432 This submittal is auto- generated based on user - selected inputs. Therefore, Hilti makes no representation as to the suitability of these systems for their intended use. Hilti. Outperform. Outlast. 11 Hilti Firestop Saving lives ■ through innovation l and education Hilti, Inc. (U.S.) 1 -800- 879 -8000 www.us.hilti.com • en espanol 1 -800- 879 -5000 • P.O. Box 21148, Tulsa, Oklahoma 74121 Hilti (Canada) Corp. 1- 800 - 363 -4458 www.hitti.ca • 2360 Meadowpine Blvd., Mississauga, Ontario L5N 6S2 Firestop Submittal Package Table of Contents Firestop Systems Hilti Firestop Systems UL System # Barrier Construction Description Rating Products C -AJ -1184 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3 -1/4 ") 3 -hour FS -ONE Intumescent Firestop Sealant C -AJ -2305 Concrete Floor Concrete /Masonry Wall Max. 8" PVC or CPVC (closed or open) 2 -hour CP 648 -E Firestop Wrap Strip C -AJ -2567 Concrete Floor Concrete /Masonry Wall Max. 2" PVC, CPVC or RNC (closed or open) (sleeve optional) (AS w /sleeve = 1/4" to 1- 3/8") (AS w/o sleeve = 0" to 1 -5/8 ") 2 -hour FS -ONE Intumescent Firestop Sealant C -BJ -1046 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe 2 -hour FS -ONE Intumescent Firestop Sealant C -BJ -2014 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 2" PVC, CPVC, or Rigid Nonmetallic Conduit (closed) 2 -hour FS-ONE Intumescent Firestop Sealant C -BJ -2017 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 4" PVC or CPVC c,v) (6" Concrete) Includes Hollow Core) AS =0" to 1/2 ") 4 -hour CP 648 -E Firestop Wrap Strip C -BJ -2021 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 6" PVC, CPVC, FRPP or ABS (c,v) (Hollow Core) (AS =0" to 1/2 ") 2 -hour CP 643N Firestop Collar C -BJ -5013 Concrete Floor Concrete Hollow -Core Floor Concrete /Masonry Wall Max. 4" steel or copper with max. 1" glass fiber insulation 2 -hour FS -ONE Intumescent Firestop Sealant C -BJ -5018 Concrete Hollow -Core Floor Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access) 2 -hour FS -ONE Intumescent Firestop Sealant FS -ONE Intumescent Firestop Sealant Mineral Wool W -L -2098 Gypsum Board Wall Max. 2" PVC or CPVC (closed system only) 1 or 2 -h r FS -ONE Intumescent Firestop Sealant W -L -2236 Gypsum Board Wall Max. 8" PVC or CPVC (c,v) (AS =0" to 1 -3/8 ") 1 or 2 -h r CP 648 -E Firestop Wrap Strip W -L -2335 Gypsum Board Wall Max. 4" PVC, CPVC, or 1 or 2 -h CP 648 -E Firestop Wrap HIM. Outperform. Outlast. THilti Fireetop Saving lives through innovation and education Hlr ,;c :1i $+ 1- BCO- h79 -c.-CC www.us.hilt,com • en e.sl:aiicl'_$8U- << "79 -5 wC • P0. Bo,, 211c8. T+.,Isa ,a17+++121 H- i Ca ^ada Carp. - 8CC -2' 3 -4458 www.hilti.ca • 2'3+30 .le.- -;1, ;ine Bl;d. '-.h .i s.:_._ • • Hits Firestop Systems Firestop Submittal Package Table of Contents Product Data Sheet(s) / Material Safety Data Sheet(s) (MSDS) CP 643N Firestop Collar CP 648 -E Firestop Wrap Strip FS -ONE Intumescent Firestop Sealant Mineral Wool Hilts. Outperform. Outlast. Hilts Fireatop Saving lives through innovation and education H )ti. ! i.5) 1- 800 -879- CCC www.ue.hilti.com • en e>paiicl 14.tCO- 79 -SCaCC • 20. Box 211,::8. 3 01,1a;-.0.r113 74121 H ti 3nada c p. 1 -HCC 3i 3 -4458 www.hilti.ea • 23:S.0 .le _oe ;in BP: J . }i ise., Cnt..no 5' 1 532 ABS (closed or open) r Strip W -L -2447 Gypsum Board Wall Max. 6" PVC, CPVC, or ABS (closed or open) 1,2,3 or 4 -hr CP 648 -E Firestop Wrap Strip Product Data Sheet(s) / Material Safety Data Sheet(s) (MSDS) CP 643N Firestop Collar CP 648 -E Firestop Wrap Strip FS -ONE Intumescent Firestop Sealant Mineral Wool Hilts. Outperform. Outlast. Hilts Fireatop Saving lives through innovation and education H )ti. ! i.5) 1- 800 -879- CCC www.ue.hilti.com • en e>paiicl 14.tCO- 79 -SCaCC • 20. Box 211,::8. 3 01,1a;-.0.r113 74121 H ti 3nada c p. 1 -HCC 3i 3 -4458 www.hilti.ea • 23:S.0 .le _oe ;in BP: J . }i ise., Cnt..no 5' 1 532 A UL /cUL SYSTEM NO. C -AJ -1184 METAL PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL F- RATING = 3 -HR. T- RATING = 0 -HR. TOP VIEW A SECTION A -A 1. CONCRETE FLOOR OR WALL ASSEMBLY (3 -HR FIRE - RATING): •A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR OR WALL (MIN. 4 -1/2" THICK). B. PRECAST (HOLLOW -CORE) CONCRETE FLOOR (MIN. 7 -1/2" THICK). C. ANY UL /ULC CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 10" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 10" NOMINAL DIAMETER CAST IRON PIPE. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 4" NOMINAL DIAMETER EMT OR STEEL CONDUIT. 3. MINIMUM 1" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT FLUSH WITH TOP OR BOTTOM OF FLOOR. (SEE NOTE NO. 3 BELOW). 4. MINIMUM 1/2" CROWN HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 14" FOR NORMAL CONCRETE, 7" FOR PRECAST (HOLLOW CORE) CONCRETE. 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 3 -1/4 ". 3. MINIMUM 1" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT IS REQUIRED ON BOTH ON BOTH SIDES OF A WALL ASSEMBLY. 4. WHEN PRECAST (HOLLW -CORE) UNITS ARE USED, HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT SHALL BE INSTALLED FLUSH WITH LOWER SURFACE OF FLOOR. 5. MINERAL WOOL MAY BE USED AS A BACKER FOR PROPER INSTALLATION OF FIRESTOP SEALANT. caj 1184k.083199 FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 1/8 " =1" Date AUGUST 31, 1999 Drawing No. CAJ 1184k Saving Lives through innovation and Education A UL SYSTEM NO. C -AJ -2305 PLASTIC PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL F- RATING = 2 -HR. T- RATING = 1- 1 /2 -HR. BOTTOM VIEW SECTION A -A CAJ2305e.070705 1. CONCRETE FLOOR OR WALL ASSEMBLY (2 -HR. FIRE - RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR OR WALL (MINIMUM 4 -1/2" THICK). B. ANY UL CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 8" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 8" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 3. MINIMUM 1/2" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 4. MINIMUM 1/4" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. 5. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1-3/4" WIDE) INDIVIDUALLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, COVERING FOUR TIMES, WITH ENDS BUTTED AND HELD IN PLACE WITH TAPE. WRAP STRIP TO BE BUTTED TIGHTLY AGAINST BOTTOM SURFACE OF FLOOR. 6. HILTI RETAINING COLLAR WRAPPED OVER THE WRAP STRIPS, OVERLAPPING MINIMUM 1 ". 7. HILTI COLLAR CLAMP(S) FASTENED AT MID - HEIGHT OF HILTI RETAINING COLLAR. 8. EVERY OTHER TAB OF RETAINING COLLAR SECURED TO BOTTOM OF FLOOR WITH 1/4" x 1 -3/4" LONG STEEL EXPANSION BOLTS, 3/16" x 1 -3/4" LONG STEEL CONCRETE SCREW ANCHORS OR 0.145 DIAMETER x 1 -1/4" LONG POWDER ACTUATED FASTENERS IN CONJUNCTION WITH 1- 7/16" DIAMETER STEEL WASHERS (EX. HILTI KWIK -BOLT 3, KWIK -CON OR DX PINS). NOTES : 1. MAXIMUM DIAMETER OF OPENING = 10". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1 -3/8 ". 3. CLOSED OR VENTED PIPING SYSTEMS (PVC = SCHEDULE 40; CPVC = SDR 13.5). 4. HILTI CP 648E WRAP STRIP WITH RETAINING COLLAR, AND HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT ARE REQUIRED ON BOTH SIDES OF A WALL. FIRESTOP SYSTEMS HILT!, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 9164 " =1" Date July 07, 2005 Drawing No. CAJ 2305e Saving Lives through Innovation and Education UL SYSTEM NO. C -AJ -2567 PLASTIC PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL ASSEMBLY F- RATING = 2 -HR. co T- RATING = 0 -HR., 1 1 /4 -HR., OR 2 -HR. o L- RATING AT AMBIENT = LESS THAN 1 CFM /SQ. FT. N. L- RATING AT 400 °F = 4 CFM /SQ. FT. N TOP W SECTION A -A 0 4 A . . a . • a • • .z .40/ • . 4 • . .. ® . 0 A 0 ©© • iii FEN 111,A .. .. : Q d • • O 1. CONCRET A. LIGHTWEIGHT B. LIGHTWEIGHT C. PRECAST D. ANY UL 2. [OPTIONAL] EXTEND MAXIMUM 3. PENETRATING A. MAXIMUM B. MAXIMUM C. MAXIMUM D. MAXIMUM SYSTEM 4. MINIMUM 4" 5. MINIMUM 1/2" 6. MINIMUM 1/2" FLOOR OR WALL ASSEMBLY ( -HR. FIRE - RATING). OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 4 -1/2" THICK). OR NORMAL WEIGHT CONCRETE WALL (MINIMUM 5" THICK). (HOLLOW -CORE) CONCRETE FLOOR (MINIMUM 6" THICK). CLASSIFIED CONCRETE BLOCK WALL. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE SLEEVE (SCHEDULE 40 OR HEAVIER) MAY 3" ABOVE FLOOR, OR BOTH SIDES OF WALL. ITEM TO BE ONE OF THE FOLLOWING : 2" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). 2" NOMINAL DIAMETER CPVC PLASTIC PIPE. 2" NOMINAL DIAMETER RIGID NONMETALLIC CONDUIT (RNC). 2" NOMINAL DIAMETER CROSS- LINKED POLYETHYLENE (PEX) TUBING (CLOSED PIPING ONLY). THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED. DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 4 ". 2. ANNULAR SPACE [WITH SLEEVE] = MINIMUM 1/4 ", MAXIMUM 1 -3/8 ". 3. ANNULAR SPACE [WITHOUT SLEEVE] = MINIMUM 0 ", MAXIMUM 1-5/8". 4. WHEN HOLLOW -CORE FLOOR ARE USED, MINERAL WOOL MUST BE INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR. 5. CLOSED OR VENTED PIPING SYSTEM (PVC, RNC = SCHEDULE 40; CPVC = SDR 17; PEX = SDR 9). 6. MINIMUM 1/2" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT IS REQUIRED ON BOTH SIDES OF A WALL. HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Drawing No. CAJ 2567c Hilti Firestop Systems Scale 5/32" =1" Date June 04,2008 Saving Lives through Innovation and Education UL /cUL SYSTEM NO. C -BJ -1046 METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. T- RATING = 1 /4 -HR. TOP VIEW SECTION A -A 1. ANY UL /ULC CLASSIFIED PRE -CAST HOLLOW CORE CONCRETE FLOOR ASSEMBLY (MINIMUM 8" THICK) (2 -HR. FIRE - RATING). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST IRON PIPE. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 3. MINIMUM 1" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND INSTALLED FLUSH WITH THE BOTTOM SURFACE OF THE FLOOR. 4. MINIMUM 1" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND RECESSED FROM THE TOP SURFACE OF THE ASSEMBLY TO ACCOMMODATE FIRESTOP SEALANT. 5. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 6. MINIMUM 1/4" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 6 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1 -7/8 ". CBJ1046a.080102 1 L__! 0® FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 118 " =1" Date Aug. 1, 2002 Drawing No. CBJ 1046a Saving Lives through Innovation and Education UL SYSTEM NO. C -BJ -2014 PLASTIC PIPE THROUGH HOLLO -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. T- RATING = 2 -HR. TOP VIEW • 1 :4 4. • 4, i(< I . I .b4 1 1 1 •41 I: . " I • . i • .'14• 14" SECTION A -A CBJ2014b.071403 1. ANY UL/ULC CLASSIFIED PRE -CAST HOLLOW CORE CONCRETE FLOOR ASSEMBLY (MINIMUM 8" THICK) (2 -HR. FIRE - RATING). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 2" NOMINAL DIAMETER PVC PLASTIC PIPE (SCHEDULE 40) (CELLULAR OR SOLID CORE) (CLOSED PIPING SYSTEM). B. MAXIMUM 2" NOMINAL DIAMETER CPVC PLASTIC PIPE (SDR 13.5) (CLOSED PIPING SYSTEM). C. MAXIMUM 2" NOMINAL DIAMETER RNC (RIGID NONMETALLIC CONDUIT). 3. MINIMUM 1" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND INSTALLED FLUSH WITH THE BOTTOM SURFACE OF THE FLOOR. 4. MINIMUM 1" THICKNESS MINERAL WOOL (MINIMUM 4 PCF DENSITY) TIGHTLY PACKED AND RECESSED FROM THE TOP SURFACE OF THE ASSEMBLY TO ACCOMMODATE FIRESTOP SEALANT. 5. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 6. MINIMUM 1/4" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 4 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1-5/8". c ]1P moo• FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 118 " =1" Date July 14, 2003 Drawing No. CBJ 2014b Saving Lives through Innovation and Education UL SYSTEM NO. C -BJ -2017 PLASTIC PIPE THROUGH CONCRETE FLOORJWALL OR BLOCK WALL F- RATING = 4 -HR. T- RATING = 4 -HR. BOTTOM VIEW A A SECTION A -A CBJ2017c.091807 1. CONCRETE FLOOR ASSEMBLY OR WALL (4 -HR. FIRE - RATING) : A. ANY LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR OR WALL (MINIMUM 6" THICK). B. PRECAST (HOLLOW -CORE) CONCRETE FLOOR (MINIMUM 6" THICK). C. ANY UL CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 4" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 3. MINIMUM 1/2" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 4. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1 -3/4" WIDE) CONTINUOUSLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, COVERING THREE TIMES, WITH ENDS BUTTED AND HELD IN PLACE WITH TAPE. 5. HILTI RETAINING COLLAR WRAPPED OVER WRAP STRIPS, OVERLAPPING MINIMUM 1 ". 6. HILTI COLLAR CLAMP(S) FASTENED AT MID - HEIGHT OF HILT! RETAINING COLLAR. 7. EVERY OTHER TAB OF RETAINING COLLAR SECURED TO BOTTOM OF FLOOR WITH 1/4" x 1 -3/4" LONG STEEL EXPANSION BOLTS, 3/16" x 1-3/4" LONG STEEL CONCRETE SCREW ANCHORS OR 0.145 DIAMETER x 1 -1/4" LONG POWDER ACTUATED FASTENERS IN CONJUNCTION WITH 1-7/16" DIAMETER STEEL WASHERS (EX. HILTI KWIK -BOLT 3, KWIK -CON OR DX PINS). NOTES : 1. MAXIMUM DIAMETER OF OPENING = 5 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 112 ". 3. CLOSED OR VENTED PIPING SYSTEM (PVC = SCHEDULE 40, CPVC = SDR 13.5). 4. HILTI CP 648E WRAP STRIP WITH RETAINING COLLAR AND FS -ONE INTUMESCENT FIRESTOP SEALANT ARE REQUIRED ON SIDES OF A WALL ASSEMBLY. Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Sheet 1 of 1 Scale 3116 " =1" Date Sep. 18, 2007 Drawing No. CBJ 2017c Saving Lives through Innovation and Education UL SYSTEM PLASTIC PIPE THROUGH PRE -CAST NO. C -BJ -2021 (HOLLOW CORE) CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. o T- RATING = 2 -HR. Y 0 BOTTOM VIEW SECTION A -A o N m U . •d • • • t'�,d • . a • 4 a ° 0 ° � e d N. 1. PRECAST 12. PENETRATING A. MAXIMUM B. MAXIMUM C. MAXIMUM 3. MINIMUM 4. HILTI 5. EACH BOLTS (HOLLOW CORE) CONCRETE FLOOR ITEM TO BE ONE OF THE 6" NOMINAL DIAMETER PVC 6" NOMINAL DIAMETER ABS 6" NOMINAL DIAMETER CPVC 1/2" DEPTH HILTI FS -ONE INTUMESCENT CP 643N FIRESTOP COLLAR WITH FASTENING HOOK SECURED TO BOTTOM IN CONJUNCTION WITH 3/4" DIAMETER ASSEMBLY (MINIMUM 6" THICK) (2 -HR. FIRE - RATING). FOLLOWING : (ALSO SEE NOTE NO. 2 BELOW) : PLASTIC PIPE (CELLULAR AND SOLID CORE). PLASTIC PIPE (CELLULAR AND SOLID CORE). PLASTIC PIPE. FIRESTOP SEALANT. FASTENING HOOKS (SEE TABLE BELOW). OF FLOOR WITH 1/4" x 1 -3/4" LONG STEEL EXPANSION STEEL WASHERS (EX. HILTI KWIK -BOLT 3). NOMINAL PIPE DIAMETER PRODUCT DESCRIPITION NO. OF FASTENING HOOKS MAXIMUM HOLE SIZE 1 -1/2" CP 643 50/1.5" N 2 2 -118" 2" CP 643 63/2" N 2 2-5/8" 3" CP 643 90/3" N 3 4" 4" CP 643 110/4" N 3 5" 6" CP 643 160/6" N 4 7" NOTES : 1. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1/2 ". 2. CLOSED OR VENTED PIPING SYSTEMS (PVC, ABS = SCHEDULE 40; CPVC = SDR 17). Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Sheet 1 of 1 Drawing No CBJ 2021h Scale 9164" =1" Date Sep. 18, 2007 Saving Lives through Innovation and Education UL /cUL SYSTEM NO. C -BJ -5013 INSULATED METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. T- RATING =1 -HR. TOP VIEW A SECTION A -A 1. ANY UL /ULC CLASSIFIED PRE -CAST HOLLOW CORE CONCRETE FLOOR ASSEMBLY (MIN. 8" THICK) (2 -HR. FIRE - RATING). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. 3. NOMINAL 1" THICKNESS GLASS -FIBER PIPE INSULATION. 4. MINIMUM 1" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED AND INSTALLED FLUSH WITH THE BOTTOM SURFACE OF THE FLOOR. 5. MINIMUM 1" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED AND RECESSED FROM THE TOP SURFACE OF THE ASSEMBLY TO ACCOMMODATE FIRESTOP SEALANT. 6. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 7. MINIMUM 1/4" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 6 ", 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 7/8 ". CBJ5013a.080902 1°C DOP FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 118 " =1" Date Aug. 9, 2002 Drawing No. CBJ 5013a Saving Lives through Innovation and Education UL /cUL SYSTEM NO. C -BJ -5018 INSULATED METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 3 -HR. T- RATING = 1 /2 -HR. TOP, VIEW 1. ANY UL CLASSIFIED PRE -CAST HOLLOW -CORE CONCRETE FLOOR ASSEMBLY (MINIMUM 8" THICK) (3 -HR. FIRE - RATING). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE OR TUBING. 3. NOMINAL DIAMETER 1" THICK AB /PVC PIPE INSULATION. 4. MINIMUM 1" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED AND INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR. 5. MINIMUM 1" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED AND RECESSED FROM THE TOP SURFACE OF THE ASSEMBLY TO ACCOMMODATE FIRESTOP SEALANT. 6. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 7. MINIMUM 1/4" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 7 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 7/8 ". I Hilti Firestop Systems CBJ5018a.021507 HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Sheet 1 of 1 Scale 9164 " =1" Date Feb. 15, 2007 Drawing No. CBJ 5018a Saving Lives through Innovation and Education UL SYSTEM NO. W -L -2098 CLOSED PVC /CPVC PLASTIC PIPE THROUGH 1 -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY F- RATING = 1-HR. OR 2 -HR. T- RATING = 1-HR. OR 2 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFM /SQ. FT. L- RATING AT 400 °F = 4 CFM /SQ. FT. FRONT VIEW A SECTION A -A WL2098d.071403 1. GYPSUM WALL ASSEMBLY (UL CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE- RATING) (2 -HR. SHOWN). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 2" NOMINAL DIAMETER PVC PLASTIC PIPE (SCHEDULE 40) (CLOSED PIPING SYSTEM). B. MAXIMUM 2" NOMINAL DIAMETER CPVC PLASTIC PIPE (SDR 17) (CLOSED PIPING SYSTEM). 3. HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT: A. MINIMUM 5/8" DEPTH OF SEALANT FOR A 1 -HR. FIRE - RATING. B. MINIMUM 1 -1/4" DEPTH OF SEALANT FOR A 2 -HR. FIRE - RATING. NOTES : 1. MAXIMUM DIAMETER OF OPENING = 4 -3/8 ". 2. ANNULAR SPACE = MINIMUM 3/4 ", MAXIMUM 1- 114 ". H_rEJ® FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 5/16 " =1" Date July 14, 2003 Drawing No. WL 2098d Saving Lives through Innovation and Education UL SYSTEM NO. W -L -2236 PLASTIC PIPE THROUGH GYPSUM WALL ASSEMBLY F- RATING =1 -HR. OR 2 -HR. T- RATING = 1-HR. OR 1- 114 -HR. FRONT VIEW A A 1. GYPSUM WALL ASSEMBLY (UL CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). 2. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 3 -1/2" WIDE. 3. [OPTIONAL] NO. 8 STEEL WIRE MESH SLEEVE (SEE NOTE NO. 4 BELOW). 4. PENETRATING ITEM TO BE ONE OF THE FOLLOWING (SEE NOTE NO. 3 BELOW) : A. MAXIMUM 8" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 8" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 5. MINIMUM 1/2" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 6. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1 -3/4" WIDE) INDIVIDUALLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, COVERING FOUR TIMES, WITH ENDS BUTTED AND HELD IN PLACE WITH TAPE. BUTTED ENDS IN SUCCESSIVE LAYER SHALL BE OFFSET. WRAP STRIP TO BE BUTTED TIGHTLY AGAINST SURFACE OF THE WALL. 7. HILTI RETAINING COLLAR WRAPPED OVER THE WRAP STRIPS, OVERLAPPING MINIMUM 1 ". 8. HILTI COLLAR CLAMP(S) FASTENED AT MID- HEIGHT OF HILTI RETAINING COLLAR. 9. EVERY OTHER TAB OF RETAINING COLLAR SECURED TO GYPSUM WALL WITH 1/8" DIAMETER x 2 -114" LONG, STEEL HOLLOW WALL ANCHORS WITH 1/2" DIAMETER WASHERS. SECTION A -A © ii! OAce:. NOTES : 1. MAXIMUM DIAMETER OF OPENING =10 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1-3/8". 3. CLOSED OR VENTED PIPING SYSTEM (PVC = SCHEDULE 40; CPVC = SDR 13.5). 4. STEEL WIRE MESH SLEEVE MUST HAVE A MINIMUM 2" LAP ALONG THE LONGITUDINAL SEAM. LENGTH OF STEEL MESH SLEEVE TO BE 1/2" LESS THAN THICKNESS OF WALL. WL2236d.121007 Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Sheet 1 of 1 Scale 118 " =1" Date Dec. 10, 2007 Drawing No. WL 2236d Saving Lives through Innovation and Education UL SYSTEM NO. W -L -2335 PLASTIC PIPE THROUGH GYPSUM WALL ASSEMBLY F- RATING =1 AND 2 -HR. T- RATING = 314,1 AND 1-1/2-HR. FRONT VIEW SECTION A -A A 1. GYPSUM WALL ASSEMBLY (UL CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). 2. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM •2 -112" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING (ALSO SEE NOTE NO. 3 BELOW) : A. MAXIMUM 4" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 4" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 4" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 4. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 5. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1" WIDE) CONTINUOUSLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, AS SPECIFIED IN THE TABLE BELOW, AND HELD IN PLACE WITH TAPE. 6. HILTI RETAINING COLLAR WRAPPED OVER WRAP STRIPS, OVERLAPPING MINIMUM 1 ". 7. HILTI COLLAR CLAMP(S) FASTENED AT MID - HEIGHT OF RETAINING COLLAR. 8. EVERY OTHER TAB OF RETAINING COLLAR SECURED TO GYPSUM WALL WITH 1-1/4" LONG STEEL LAMINATE DRYWALL SCREWS IN CONJUNCTION WITH 1-1/4" DIAMETER FENDER WASHERS. NOMINAL PIPE DIAMETER NO. OF LAYERS OF CP 648E 2" (OR SMALLER) 2 4" (OR SMALLER) 3 NOTES : 1. MAXIMUM DIAMETER OF OPENING = 5 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1/2". 3. CLOSED OR VENTED PIPING SYSTEMS (PVC & ABS = SCHEDULE 40; CPVC = SDR 13.5). 7 FIRESTOP SYSTEMS 17-u-'0® HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 118" =1" WL2335b.062105 Date June 21, 2005 Drawing No. WL 2335b Saving Lives through Innovation and Education UL SYSTEM NO. W -L -2447 PLASTIC PIPE THROUGH GYPSUM WALL ASSEMBLY F- RATING = 1, 2, 3 OR 4 -HR. L- RATING AT AMBIENT = 3 CFM/SQ. FT. T- RATING =1, 2, 3 OR 4 -HR. L- RATING AT 400 °F = LESS THAN 1 CFM/SQ. FT. FRONT VIEW SECTION A -A A C- 1. GYPSUM WALL ASSEMBLY (UL /cUL CLASSIFIED U400 OR V400 SERIES) (1, 2, 3 OR 4 -HR. FIRE - RATING) (4 -HR. SHOWN). 2. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 3-1/2" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING (ALSO SEE NOTE NO. 3 BELOW) : A. MAXIMUM 6" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 6" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 6" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). 4. MINIMUM 1/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 5. HILTI CP 648E WRAP STRIP (NOMINAL 3/16" THICK x 1-3/4" WIDE) CONTINUOUSLY WRAPPED AROUND THE OUTER CIRCUMFERENCE OF THE PIPE, AS SPECIFIED IN THE TABLE BELOW, AND HELD IN PLACE WITH TAPE. 6. HILTI RETAINING COLLAR WRAPPED OVER WRAP STRIPS, OVERLAPPING MINIMUM 1 ". 7. HILTI COLLAR CLAMP(S) FASTENED AT MID - HEIGHT OF RETAINING COLLAR. 8. EVERY OTHER TAB OF RETAINING COLLAR SECURED TO GYPSUM WALL WITH 1-1/4" LONG STEEL LAMINATE DRYWALL SCREWS IN CONJUNCTION WITH 1-1/4" DIAMETER FENDER WASHERS. NOMINAL PIPE DIAMETER NO. OF LAYERS OF CP 648E 2" (OR SMALLER) 1 4" (OR SMALLER) 2 6" (OR SMALLER) 3 NOTES : 1. MAXIMUM DIAMETER OF OPENING = 7 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1/2". 3. CLOSED OR VENTED PIPING SYSTEMS (PVC & ABS = SCHEDULE 40; CPVC = SDR 13.5). WL2447a.091305 OP LT-u-' FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 7164 " =1" Date Sep. 13, 2005 Drawing No. WL 2447a Saving Lives through Innovation and Education • • Product information CP 643N Firestop Collar Product description • A ready - to-use firestop collar, made of a galvanized steel housing and intumescent inserts for firestopping combustible pipes Product features • Ready - to-use collar • No construction required • Fast Installation time • Adjustable mounting tabs • Low profile for tight installations Areas of application • Firestopping combustible pipes up to 6" diameter in penetrations through fie walls and floors • Suitable for the following pipe materials: • PVC, CPVC, ABS, PVDF, PP and FRPP For use with • Concrete, masonry, wood floor and gypsum wall assemblies • Wall and floor assemblies rated up to 4 hours Types of installation • Wall: two collars, one on each side • Floor. one collar on underside (bottom) Example • Waste water pipes • Fresh water pipes installation instructions for CP 643N Technical Data Fie outside Description dia (in.) Collar outside dia. (in.) CP 643N Collar Height (in.) No. of hooks and fasteners CP 643 - 50/1.5 "N 1.4 -2.0 2.8 0.9 2 CP 643- 63/2 "N 2.0 -2.5 3.4 1.3 2 CP 643- 90/3 "N 2.6 -3.6 4.9 1.7 3 CP 643- 110/4 "N 3.6 -4.5 6.0 1.9 3 CP 643- 160/6 "N 6.6 9.8 1.9 4 Temperature resistance -40°F to 40 °F (-40°C to 60°C) Intumescent activation Approx. 392 °F (200 °C) Expansion ratio (taut) Up to 1:10 Approvals • California State Fire Marshal - No. 4485- 1200:113 No. 4485- 1200:131 • City of New York - MEA 630 -06-M Tested In accordance with • UL1479 •ASTME814 Psa,eF RRESTOP MACE 0 , FOR USE IM TP MSTRATION tO IbP SYSTEMS US UL FIRE RESSTANCE DSFRECTORY SP176 APPROVED Notice • Before handling. read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the plastic pipes. Expansion of the intumescent material during a fire acts to close the plastic pipe. Very dirty pipes (le: with remains of mortar) may lead to a delay in this closing action. Soiled plastic pipes should, therefore, be cleaned in the area where the CP 643N Firestop Collar is to be installed. Application of firestop system 2. Seal the opening if required. Gaps may be closed with FS -ONE. The approved methods vary and are given in the specific UL system. 3. Close the CP 643N Firestop Collar. Place the CP 643N Firestop Collar around the plastic pipe and lock the closure by applying firm pressure until it latches. 4. Attach fastening hooks. The fastening hooks can be attached to various points on the metal housing. This allows the fastening points to be made to suit the space available in each case. The hooks must be positioned as symmetrically as possible. The required number of fastening hooks is indicated on the packaging. 2. Close remaining gap to provide smoke and gas resistant seal Hilti Firestop Saving Uves through innovation and education 3. Close collar. 4. Attach fastening hooks. 5. Fasten collar and kfentmcmlon plate (g 'equtmct. 5. Fastening the CP 643N Firestop Collar. Only when fastened properly can CP 643N offer protection against fire. a. Mark the fastening points. b. Dui holes with a MI6 rotary hammer drill (i.e. TE 4-A18) or, depending on base material, fasten using Hilti powder- actuated tool. c. To secure the CP 643N Firestop Collar, use Hilti anchors/fasteners. d. For maintenance reasons, a penetration can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • with metal pipes • In highly corrosive surroundings • with unapproved anchors/fasteners Storage • Store only in the original packaging in a location protected from moisture Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1- 800 - 879 -8000 • wwwus.hflti.com • en espaflol 1- 800 - 879 -5000 • Hilti Firestop Systems Guide • Certificate Number 20069214-R15431 Report Reference 2006 February 14 Issue Gate 2006 February 14 Issued to: Hilts, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that representative samples of Paget of 1 Underwriters Laboratories Inc., Firestop Devices CP643N 50/1.5 in., CP643N 63/2 in., CP643N 90/3 in. and CP643N 110/4 in., CP643N 160/6 in., CP644 200/8 in. and CP644 250/10 in. Have been investigated by Underwriters Laboratories Inc. ts; in accordance with the Standard(s) indicated on this Certificate. • Standard(s) for Safety: ANSUUL 1479, CAN/ULC -S 115 -05 • Additional Information: CP 643N and CP 644 Firestop Collar for use in Through - Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow -Up Service. T'he UL Classification Mark includes: UL in a circle symbol- g with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL: a statement to indicate the extent of UL's evaluation of the product; and. the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product issued by: „ Reviewed b Mona Couloute Christoph Underwriters Laboratories Inc. Underwrit f�11LT1 '' CP 648 -E Firestop Wrap Strip Product description • An intumescent, flexible firestop wrap strip for plastic and insulated pipe penetrations Product features • Highly Intumescent • Long length avoids waste • Can be continuously wrapped • Cost effective • Quick and easy closure without tools • Ideal for very tight installations Areas of application • Firestopping combustible pipe penetrations • Difficult applications where space is limited i Penetrations through concrete over metal deck • Plastic and insulated penetrations using PVC, CPVC, ABS, FRPP and PEX For use with • Concrete, masonry, wood floor and gypsum wall assemblies • Wall and floor assemblies rated up to 4 hours Examples • Waste water pipes • Fresh water pipes • Decking penetrations Installation instructions for CP 648-E Product Information Technical Data* Density CP 648-E Approx. 1.35 g/ome Dimensions (approximate) 3/16" x 1" x 33 ft or VS" x1- 3/4 "x33ft Color Black with foil backing Temperature resistance -40°F to 212°F (-40°C to 100°C) Intumescent activation Approx. 320°F (160°C) Expansion ratio (unrestricted) 1:40 Approvals *California State Fire Marshal - No: 4485- 1200:126 • City of New York - MEA 313 -07 -M Tested in accordance with •UL1479 •ASTME814 -At 73°F (23°C) and 50% relative humidity ,ssrg,4, FOR U, VOID OR UGH- MATERIAL c FOR USE W TI- PENETRATION FIRESTOP SYSTEMS C tISSEE Ut. FIRE RESISTANCE DIRECTORY S8Y7 Notice • Before handling, read Material Safety Data Sheet and product (abet for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing In the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the plastic or insulated pipe penetration. Expansion of the intumescent material during a tire closes the plastic or insulated pipe penetration. Very dirty pipes lie: with remains of mortar) may lead to a delay In this closing action. Soiled plastic pipes or insulated pipe penetrations should, therefore, be cleaned in the area where the CP 648-E Firestop Wrap Strip is to be installed. 1. Clem penetration 2. Wrap stripe armed 3. Push Wrap Strips pipe the specified rumbas into tie of times OP/ 4. Seal penetration against S. Fasten installation plate smoke with FS-ONE If required) Hilti. Outperform. Outlast. Application of firestop system 2. Tightly wrap the required number of strips continuously around the penetrant, and hold in place with tape. 3. Push the Hilti Wrap Strip into the opening until it is flush with the substrate surface unless otherwise required by the UL system. It may be required by the UL system to damp. wire or use a Hilti Retaining Collar to secure the wrap strip in place for some applications. 4. It the UL system requires a cold smoke seal, then apply the proms amount of Hilti FS-ONE °astlant in the opening over the wrap strip. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • In highiy corrosive surroundings • With unapproved retaining collars, anchors/fasteners • Outdoors Storage • Store only in the original packaging in a location protected from moisture at temperatures between 23°F and 86°F (-5 °C and 30°C). IiHilti Firestop Saving Lives through innovation and education Hilts, Inc. (U.S.) 1- 800 - 879 -8000 • www.us.hilti.com • en espariol 1- 800 -879 -5000 • Hilt Firestop Systems Guide • • Material Safety Data Sheet Product name: Description: Supplier: Emergency # (Chem- Trec.): MSDS No.: Revision No.' Revision Date: Page: CP 648 -S & CP 648 -E Firestop Wrap Strip 1° or 1 3/4° wide — intumescent wrap for plastic or insulated pipe Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 1 800 424 9300 (USA, PR Virgin Islands, Canada); 703 527 3887 (Other countries) 302 002 02/28/05 1 of 2 INGREDIENTS AND EXPOSURE LIMITS Not a hazardous chemical as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200 PHYSICAL DATA Appearance: Vapor Density: (air =1) Boiling Point Evaporation Rate: Density: Dark gray colored putty strips. Not applicable. Not applicable. Not applicable. 1.3 -1.4 g/cm' Odor: Vapor Pressure: VOC Content Solubility in Water: pH: Mild odor. Not applicable. 7.6 O. Not determined. Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits: Not applicable. Extinguishing Media: Use extinguishing media appropriate for the surrounding fire. Special Fire Fighting Procedures: None known. Unusual Fire and Explosion Hazards: None known. Product serves as a firestop; intumescent material begins to expand when exposed to temperatures > 160o C (3200 9 REACTIVITY DATA Stability: Incompatibility: Decomposition Products: Stable. None known. None known. Hazardous Polymerization: Will not occur. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Signs and Symptoms of Exposure: Routes of Exposure: Carcinogenicity: Medical Conditions Aggravated by Exposure: Irritation of the eyes and skin is possible with some individuals. Eyes: Can cause irritation and watering but injury is unlikely. Skin: Irritation. is possible with some individuals. Inhalation: No effects expected. Ingestion: Not a likely route of exposure. Can cause irritation. Considered to have a tow acute oral toxicity. Contact. No ingredients are classified as a carcinogen by IARC. NTP or OSHA. None known. EMERGENCY AND FIRST AID Eyes: Skin: inhalation: Ingestion: Other: PROCEDURES Immediately flush with plenty of water. Call a physician if symptoms occur. Wash with soap and water. Seek medical attention if any effects persist. Not applicable Only induce vomiting if directed by a physician. Contact a physician immediately. Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. Hilti. Outperform. Outlast. '-800-879.800C • www,us.hilti.com • 1.8C3-879 -5CCC • 11:4 HMI Firestop Saving Lives ; through innovation L and education - 8C0.363 -4453 www.hilti.Ca Material Safety Data Sheet MSDS No.: Revision No.: Revision Date: Page: 302 002 02/28/05 2 of 2 CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection - Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Cloth gloves are suitable; impermeable (neoprene or rubber) gloves recommended. Respiratory Protection: Not required. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Avoid prolonged or repeated contact with the skin. Do not rub the eyes after contact with the hands. Practice good hygiene; Le. wash after using and before eating or smoking. Store above 32° F and below 140° F (0 - 60° C). For industrial use only. Keep out of reach of children. Spill Procedures: No special requirements. REGULATORY INFORMATION Hazard Communication: HMIS Codes: DOT Shipping Name: IATA / ICAO Shipping Name: TSCA Inventory Status: SARA Title III, Section 313: EPA Waste Code(s): Waste Disposal Methods: Not a hazardous chemical as defined by the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. Health 1, Flammability 0, Reactivity 0, PPE B Not regulated. Not regulated. Chemical components listed on TSCA inventory. This product does not contain any ingredients which are subject to reporting under Section 313 of SARA Title HI (40 CFR Part 372). Not regulated by EPA as a hazardous waste Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: Health / Safety: Emergency # (Chem - Trec): 1 800 879 8000 Technical Service: 1 800 879 8000 1 800 879 6000 Jerry Metcalf (x6704) 1 800 424 9300 (USA, PR, Virgin Islands, Canada): 703 527 3887 (Other countries) The information and recommendations contained herein are based upon data believed to be correct: however. no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. H i Iti. Outperform. Outlast. -30C- 879 -8000 • www.us.hiltl.com • Hlltl Firestop Saving Lives through innovation and education -8C0- 879 -50CC • - 8CC -3663 -4458 www.hilti.ca Certificate Number 20060214- R13240L Report Reference 2006 February 14 Issue Date 2006 February 14 Issued to: This is to cert jr that representative samples of Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA Fill, Void or Cavity Materials CP 648E, CP 648S Page 1 of 1 Underwriters Laboratories Inc.. Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. • Standard(s) for Safety: ANSUUL 1479, CAN/ULC -S 115-05 Additional Information: CP 648E and CP648S (Product number may be suffixed to denote size) Wrap Strip for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow -Up Service. The UL Classification Mark includes: t 1, in a circle symbol: with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product identity) as indicated in the appropriate t:l. Directory. Look for the UL Classification Mark on the product �yL� Reviewed by: • ona ouloute Christopher t on Underwriters Laboratories Inc. Underwriters iratories Inc. • • • Product Information FiIL 1-rI FS -ONE High Performance Intumescent Firestop Sealant Product description • Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non - combustible penetrations for up to 4 hours fire rating Product features • Smoke, gas and water resistant after material has cured • Contains no halogen, solvents or asbestos • High fire rating properties • Water based, easy to dean • Protects most typical firestop penetration applications • Paintable • Single component systems available • Meets LEEDTm requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 42 Paints and Coatings Areas of application • Steel, copper and EMT pipes • Insulated steel and copper pipes • Cable bundles • Closed or vented plastic pipes • HVAC penetrations For use with • Concrete, masonry, drywall and wood floor assemblies 1 Wall and floor assemblies rated up to 4 hours Examples • Sealing around combustible pipe penetrations in fire rated construction • Sealing around non - combustible penetrations in fire rated construction installation instructions for FS -ONE Notice • Before handling. read Material Safety Data Sheet and product label for safe usage and health information. Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or HIM Firestop Systems Guide for complete installation information opening 1. Clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris. dirt. oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant 2. Install the prescribed backfllling material type and depth to obtain the desired rating (lf required). Leave sufficient depth for applying FS-ONE 3. Application of flrestop sealant Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of FS-ONE use a standard caulking gun, foil pack gun, bulk loader and bulk gun. With FS-ONE buckets, Grano type sealant pumps may be used. (Contact pump manufacturer for proper selection). Technical Data* Chemical basis FS-ONE Water -based intumescent acrylic dispersion Color Red Application temperature 40 °F to 104 °F (5 °C to 40 °C) Skin forming time Approx. 20 -30 min. Coring time Approx. 2 mm / 3 days Movement capability Approx. 5% Expansion rate (unrestricted) Up to 3-5 times original volume Temperature resistance (cured) -40 °F to 212 °F (-40 °C to 100°C) Surface burring characteristics (ASTM E 84-96) F lame Spread: 0 Smoke Development 5 Sound transmission classification (ASTM E 90-99) 56 (Relates to specific construction) Approvals • California State Fire Marshal - No. 4485- 1200:108 • City of New York - MEA 326 -96-M Vol. IV Tested In accordance with •UL1479 •ASTME814 •ASTME84 °At 73°F (23°C) and 50% relative humidity �sshw4. FILL VOID OR CAVITY MATERIAL /�� FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS naMs t SSEE UL FIRE RESISTANCE DIRECTORY 66Y7 4. Smoothing of firestop sealant To complete the seal, tool immediately to give a smooth appearance. Excess sealant. prior to curing, can be cleaned away from adjacent surfaces and tools with water. 5. Leave completed seal undisturbed for 48 hours. 6. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the identification plate and fasten it in a visible position next to the seal. Not for use • High movement expansion joints • Underwater 1. Clean cesium. 2. Peck mineral wool 3. Apply FS-ONE. TIT required) • On materials where oll, plasticizers or solvents may bleed i.e. impregnated wood oil based seals, green or partially vulcanized rubber • In any penetration other than those specifically described in this manual or the test reports Storage • Store only in the original packaging in a location protected from moisture at temperatures between 40 °F (5 °C) and 86°F (30°C) • Observe expiration date on the packag 4. Smooth FS-ONE. S. Leave completed a Fasten beneficence seal mhdkLatedfor plate Paraded). 48homa 1. Clean opening. 2. Pack mineral wool. 3. Apply FS -ONE. 8f required) 4. Smooth FS-ONE S. Leave e. Fasten identlrcadat seal undsaated for plate M required). 48 tame. Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1 -800- 879 -8000 • www.us.hiiti.com • en espalioi 1-800 -879 -5000 • Hilti Firestop Systems Guide • • • Material Safety Data Sneet Product name: Description: Supplier. Emergency # (Chem - Trec.): MSDS No.: Revision No.: Revision Date: Page: FS -ONE High Performance Intumescent Firestop Sealant One -part acrylic -based sealant Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 1 800 424 9300 (USA, PR, Virgin Islands. Canada); 001 703 527 3887 (other countries) 259 010 08/17/04 1 of 2 INGREDIENTS AND EXPOSURE LIMITS Ingredients: Polyacryiate dispersion Calcium carbonate Zinc borate Ammonium polyphosphate Talc Expandable graphite Ethylene glycol Polybutene Iron oxide Glass filament Silicon dioxide Water Abbreviations: PEL = OSHA CAS Number: Mixture 001317 -65-3 138265 -88-0 068333-79 -9 014807 -96-6 012777 -87-6 000107 -21 -1 009003 -29-6 001309 -37 -1 065997 -17 -3 014808 -60 -7 PEL: NE 5mg/m'f) NE NE 20 mppcf 5 mg/m' (T) NE NE 10 mg/m3 5 mghn3 NE 5 mg/m' (T) 0.05 mg/nr (r) 0.1 mg/m' (1) TLV: STEL: NE NE 10 mg/m3(T) NE NE NE NE NE 2 mg/rn3 NE 2 mg /rn3 m NE C:100 mg/m' (A) NE NE NE NE NE NE NE NE C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (T) indicates as total dust ". (R) indicates as respirable fraction ". (A) indicates "as an aerosol ". mppcf = million particles per cubic foot. 007732 -18 -5 NE Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. PHYSICAL DATA Appearance: Vapor Density: (air =1) Boiling Point: Evaporation Rate: Specific Gravity: Red paste. Not determined. Not applicable. Not applicable. 1.5 Odor: Vapor Pressure: VOC Content: Solubility in Water: pH: Odorless. 23mbar @ 20C / 68F 75.0 g/L. Soluble. Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Extinguishing Media: Special Are Fighting Procedures: Non - flammable. Flammable Limits: Not applicable. Not applicable. Use extinguishing media as appropriate for surrounding fire. None known. Use a self- contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability: Incompatibility: Decomposition Products: Conditions to Avoid: HEALTH HAZARD DATA Known Hazards: Signs and Symptoms of Exposure: Medical Conditions Aggravated by Exposure: Routes of Exposure: Stable. Hazardous Polymerization: Will not occur Strong acids, peroxides, and oxidizing agents. Thermal decomposition can yield CO and CO2. None known. None known. Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Eye and skin conditions. Dermal. Hilti. Outperform. Outlast. 1 -80C 7379 -8060 • www.us.hilti.com • Hilti Firestop Saving Lives through innovation and education 1.800- 879 -5000 • 1.8.3.363-4358 www hilts Ca • Carcinogenicity: Material Safety Data Sheet MSDS No.: Revision No.: Revision Date: Page: 259 010 08/17/04 2of2 !ARC classifies crystalline silica (quartz sand) as Group 1 based upon evidence among workers in industries where there has been long -term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand deaner. If material does not come off. buff with a pumice stone. Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Seek medical attention. Do riot induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended 11 there is any question about the seriousness of the injury/exposure. Inhalation: Ingestion: CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: Eye Protection: Skin Protection: Respiratory Protection: General (natural or mechanically induced fresh air movements). Not required, however, safety glasses should be worn in most industrial settings. Avoid skin contact. Cloth gloves are suitable for hand protection_ None normally required. Where ventilation is inadequate to control vapors. use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air - supplied respirator. 411/ PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene: i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow Iabeluse instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: HMIS Codes: DOT Shipping Name: IATA / ICAO Shipping Name: TSCA Inventory Status: EPA Waste Code(s): Waste Disposal Methods: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. Health 1, Flammability 0, Reactivity 0, PPE B Not regulated. Not regulated. Chemical components listed on TSCA inventory. SARA Title 111, Section 313: This product contains < 3% ethylene glycol (CAS 107 -21 -1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title 111 (40 CFR Part 372). Not regulated by EPA as a hazardous waste. Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state. and federal safety. health and environmental regulations. CONTACTS Customer Service: Health / Safety: Emergency # (Chem - Trec): 1 800 879 8000 Technical Service: 1 800 879 8000 1 800 879 6000 Jerry Metcalf (x6704) 1 800 424 9300 (USA, PR, Virgin Islands, Canada): 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however. no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Hilti. Outperform. Out last. 1- 800-879 -8CC0 • www.us.hiltt.com • 1 -800- 879 -5000 • Hilti Firestop Saving Lives through innovation ti and education -800 -363 -4458 www.hittLca • • Certificate Number 20100512-R13240 Report Reference 2010 May 12 Issue Date 2010 May 12 Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS -ONE Page 1 of 1 Underwriters Laboratories lee.a, Have been investigated by Underwriters Laboratories Inc (UL) or any authorized licensee ("fill, in accordance with the Standard(s) indicated on this Certificate. Standcird(s) for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC- S115 -05 Third Edition, revised March 1, 2010 Additional Information: FS -ONE Sealant for use in Joint Systems and FS -ONE for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle symbol: e with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL-s evaluation of the product; and, the product category naive (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification iF <'iark on the product Is�siuueed by: Reviewed Mon�� Couloutee Clads 9mnsan Underwriters Laboratories Inc. Underwriters laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (I: L) or any authorized licensee of t L. al Submittal Sheet MI 07840 • THEHMAFIBER®SaIIHg Insulation UL- and OPL- labeled* sating insulation for firestops and fire - containment systems • Firestop product for curtain wall fire and smoke containment systems, floor and wall penetrations, head -of -wall, and other construction joint systems. • Fire resistant and noncombustible. • Economical; installs quickly and easily. • Aids sound control in many assemblies. • Available in unfaced felt (plain) or with a tough scrim - reinforced foil facing (FSP). • Durable; nondeteriorating and noncorrosive. -1 Ii -bar;: THERMAFIBEFr Safing Insulation is a mineral -wool -type insulation that resists temperatures up to 2,000 °F (1,093 °C), thus offering superior fire protection in a wide variety of fire -rated applications. It is a UL- and OPL- labeled product especially intended for tested UL and OPL Designs, as well as many other fire- and smoke - tested assemblies. This product is noncombustible per Standard NFPA 220 when tested in accordance with ASTM E 136, and moisture - resistant, noncorrosive, nondeteriorating, mildew -proof and vermin - proof. It permits dry construction for ail - year -round work. Also, THERMAFIBER Safing Insulation is available plain, or with scrim - reinforced foil facing (FSP) that serves as a vapor retarder and/or smoke barrier. THERMAFIBER Safing Insulation is compatible with both THERMAFIBER''' Curtain Wall CW Insulations and THERMAFIBER FIRESPANTM' Insulations. Eire Containment. Penetrations aml Comnructioe Joints THERMAFIBER Safing Insulation is a key element in a wide variety of fire - tested construction assemblies. It is used with THERMAFIBER Curtain Wall and FIRESPAN Insulations in applications to contain both fire and smoke to the area of origin. Especially for mid - and high -rise buildings, where fire and smoke must be prevented from spreading to the next floor. Since the floor assembly is typically fire- rated, one route for the fire spread is through and up the exterior curtain wall system. THERMAFIBER Safing Insulation is also used in conjunction with various sealants and caulks, in wall and floor penetration (poke - through) applications, head -of -wall construction joints, and other construction joints. It is important to note that one of the most valuable yet misunderstood applications of THERMAFIBER Safing Insulation is its use in exterior curtain wall assemblies to safe -off the opening between concrete floor slabs and the curtain wall assemblies. Many people still believe the myth that all thermal insulations are the same when used in the curtain wall spandrel panels as long as THERMAFIBER Safing Insulation is. used in the assembly. This is simply not true. Actual fire tests have proven that low- melt- point.insulations, such as glass fiber types, will disintegrate quickly once exposed to fire, leaving the curtain wall unprotected. Then, as the now - unprotected curtain wall disintegrates or falls away, the safing insulation will no longer be supported, and the fire will spread to the floor(s) above. Effective perimeter fire containment can only be achieved when a fire- compatible product with the ability to resist high temperatures (such as THERMAFIBER Curtain Wall Insulations or THERMAFIBER FIRESPAN Insulations) is used in conjunction with the THERMAFIBER Safing Insulation, acting together as a system. (See TF685, TF686 and TF871 for additional information). �ePF.�Y.Itr 7 +1 '.. Perimeter Installation In curtain wall fire - containment applications, THERMAFIBER Safing Insulation fills the void between the slab edge and the curtain wall insulation to contain fire. Foil -faced insulation impedes the passage of smoke and noxious gases. Install THERMAFIBER Safing Insulation, of proper width (2° to 8° max. opening), compression fit in safe -off area (foil side up, if required) between THERMAFIBER FIRESPAN or CW Curtain Wall Insulation and floor slabs, on sating T clips spaced as required in the design (24° or 12° o.c. maximum), leaving no voids. Compression fitting the safing insulation is critical to assuring a tight seal. See specific test description for proper installation details. Install proper topping material, such as THERMAFIBER SMOKE SEAL Compound. or other approved smoke sealants as indicated in the spe- cific test description or architectural specification. Penetration Application THERMAFIBER Safing Insulation provides a noncombustible, fire - resistant forming /packing material for many types of penetrations in walls and floor /ceilings. In all poke - through penetrations, clean substrate of dirt, dust, grease, oil, efflorescence, loose material or other matter. With a serrated knife, cut THERMAFIBER Safing Insulation slightly wider than the opening. Compress and tightly fit the minimum thickness and density of insulation required (per system specification) completely around penetrant. For floor slab openings, compress or install THERMAFIBER Safing Insulation according to details indicated in the specific test description or architectural specification to seal completely around cables, ducts, piping or other utilities. Construction Joint Application THERMAFIBER Safing Insulation is also used as a forming material in head -of -wall, floor to floor, floor to wall, and wall to wall construction joints. It is compressed and slid into joint openings to completely fill the gap between the intersection of the walls, floor, etc. UL is an abbreviation for Underwriters Laboratories Inc.; OPL is an abbreviation for Omega Point Laboratories, Inc. Ti Surface Burning Product Designation Flame Spread Characteristics Safing, Regular (Unfaced) 0 (According to ASTM E 84) Safing (Foil- Faced) 25 Products have a class A interior finish rating per NFPA 101, life safety code. Smoke Developed 0 0 Product Density Product Actual Designation Density Safing 4.0 Safing 6.0 Safing 8.0 (1) On packaging weight basis. Density Tolerance -pcl'" -0.5 +1.0 -0.75 +2.0 -1.0 +2.0 Minimum Thickness 1° 1 -1/2° 1° Application Method safing clips and/or compression fit safing clips and/or compression fit safing clips and/or compression fit For the most up -to -date technical data, please refer to our website at www.thermafiber.com Product Bata Standards Compliance THERMAFIBER Safing Insulation meets the following: ASTM C 665 - Federal Specification HH -I -521 F —Safing insulation as Types I and III, Class A, Category 1. ASTM C 612 -00 - Federal Specification HH-I-558B—Safing insulation as Types IA, IB and II. ASTM E 136 - Rated noncombustible as defined by NFPA Standard 220 when tested according to ASTM E 136. ASTM E 814 or UL 1479 - Safing insulation used in conjunction with SMOKE SEAL Compound, or other approved material in through - penetration firestop systems. UL 2079 - Safing insulation used in conjunction with various sealants and caulks in construction joint systems. ASTM C 553 - THERMAFIBER Insulations absorb less than 1% moisture by weight and volume. Safing insulation products are approved by: New York City Board of Standards & Appeals— 39 -74 -SM & MEA 209 -82 -M, Vol. II. Composition and Materials THERMAFIBER blankets are a mineral fiber material manufactured from blast furnace slag, a by- product of iron ore reduction, and naturally occurring rock. THERMAFIBER blankets contain greater than 80% post- industrial recycle content. This product contains No Asbestos. Warranty System performance following substitution of materials or compromise in assembly design cannot be certified and may result in failure of fire performance under certain conditions. Products and systems provided by Thermafiber Inc. are warranted to be free from defects in material workmanship. Contact Thermafiber Inc. for complete warranty details. Storage Store in a cool, dry place. Submittal Appronis: Job Name Contractor I Date Trademarks THERMAFIBER. FIRESPAN and THE NAME IN MINERAL WOOL are Pads- marks of Thermafiber Inc. SMOKE SEAL is a trademark of United States Gypsum Company. ihermahhelt ne/galg 0 Note Products described here may not be available in all geographic markets. Consult your local sales office or rep- resentative for information. Notice THERMAFIBER INC. shall not be liable for incidental and consequential damages. directly or indirectly sustained. nor for any loss caused by application of these goods not If accordance with current printed instructions or for other than the intended use. THERMAFIBER'S liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing within thirty (30) days from date it was or reasonably should have been discovered. Safety First! Follow good safety and industrial hygiene practices while handling and installing products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related litera- ture on products before specification and/or installation. Health Aspects Information about health aspects of using THERMAFIBER' Curtain Wall Insulation products are thoroughly explained in North American Insulation Manufacturers Association's (NAIMA) Health and Safety facts for rock and slag wool insulation document 863. Contact Thermaliber. Inc. for more details. 3711 West Mill Street Wabash, IN 46992 -8687 1- 888- TFIBERI (834 -2371) www.thermafiber.com TF612/Rev 11/06 Copyright 2004. Thermafiber Inc. Printed in U.S.A. • 480 Material Safety Data Sheet Product name: Description: Supplier: Emergency # (Chem- Trec.): �■■iLL.T1 MSDS No.: 270 Revision No.: 003 Revision Date: 06/18/03 Page: 1 of 2 Mineral wool Synthetic vitreous fiber Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: P EL: TLV: STEL: Slag wool fiber 65997 -17 -3 NE 1 fiber / cc NE Phenolic resin 09003 -35 -4 NE NE NE Polyvinyl alcohol 09002 -89 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: Boiling Point: Melting Point: Evaporation Rate: pH: 2' x 4' x 4" sheets. Not applicable. Approx. 2400° F Not applicable. Not applicable. Odor: Vapor Pressure: VOC Content: Solubility in Water: Specific Gravity: Negligible, Not applicable. Not applicable. Insoluble. Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire and Explosion Hazards: Not applicable. Flammable Limits: Not applicable. As appropriate for surrounding fire; material does not bum. Soak cartons to help prevent the spread of fire. Use a self - contained breathing apparatus when fighting fires involving chemicals. None known. REACTIVITY DATA Stability: Incompatibility: Hazardous Decomposition Products: Conditions to Avoid: Stable. Hazardous Polymerization: Will not occur. Strong acids. Thermal decomposition products can be formed at temperatures exceeding 2000° F. Thermal decomposition can yield CO and CO2. None known. HEALTH HAZARD DATA Known Hazards: Routes of Exposure: Signs and Symptoms of Exposure: Carcinogenicity: Medical Conditions Aggravated by Exposure: Acute: Eye, skin and respiratory irritation. Chronic: Respiratory impairment. Inhalation, Dermal. Eyes: Mechanical irritation. Skim Itching, irritation. Inhalation: Nose, throat and upper respiratory tract irritation. Slag wool has been classified by the IARC as Group 3 - Unclassifiable as to Carcinogenicity in Humans. Eye, skin, and respiratory conditions. Saving Lives through innovation & education Hilti Firestop Guide 2005 -2006 1- 800- 879 -8000 www.us.hilti.com • I•■11L1.T11 Material Safety Data Sheet MSDS No.: 270 Revision No.: 003 Revision Date: 06/18/03 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Flush with plenty of water while holding eyelids apart. Avoid rubbing the eyes as mechanical abrasions can occur. Call a physician if symptoms persist. Wash with soap and water. Launder clothing before reuse. Move to fresh air. No ill effects expected. Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. Skin: Inhalation: Ingestion: Other: CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: Eye Protection: Skin Protection: Respiratory Protection: General (natural or mechanically induced fresh air movements). Safety goggles recommended to prevent particulates from irritating the eyes. Cloth gloves and long sleeves to protect skin from irritating fibers. Use local exhaust and/or a NIOSH- approved dust respirator when air movement is inadequate to control dusts / fibers below recommended exposure levels. PRECAUTIONS FOR SAFE HANDLING Handling and Storing Precautions: Spill Procedures: AND USE Avoid generating dusts. Local exhaust may be required to control dusts if power tools are used for cutting / trimming. Wear appropriate personal protective equipment. Store away from moisture; keep dry. Not applicable. REGULATORY INFORMATION Hazard Communication: • HMIS Codes: DOT Shipping Name: IATA / ICAO Shipping Name: TSCA Inventory Status: SARA Title III, Section 313: EPA Waste Code(s): Waste Disposal Methods: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. Health 1, Flammability 0, Reactivity 0. PPE B (Gloves, Goggles) Not regulated. Not regulated. Chemical components listed on TSCA inventory. This product does not contain any toxic chemicals which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). Not regulated by EPA as a hazardous waste. Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: Health / Safety: Emergency # (Chem - Trec): 1 800 879 8000 Technical Service: 1 800 879 6000 Jerry Metcalf (x6704) 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) 1 800 879 8000 The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Saving Lives through innovation & education Hilti Firestop Guide 2005 -2006 1 - 879 -8000 www.us.hilti.com MII. I % 481 • • • Underwriters Laboratories Inc. CERFIF.I _ :ATE OF COMPLIANCE CERTIFICATE NUMBER: 20040809- R10905 ISSUE DATE: August 9, 2004 Issued to: Thernmattber Inc. 3711 W Mill St E:et Wabash, IN 46992 Report Reference: 810905 This is to Certify that representative samples of Forting Material, designated as Type SAF mineral wool baits. Northbrook dd 333 PFngster• Roar Vatbrook.'L 60062-22096 ILA Vila LLCM tel. 1 847 272 3800 Page 1 of 1 Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI /UL 1479, Fire Tests of Through - Penetration Firestops. ANSI /UL 2079, Test for Fires Resistance of Building Joint Systems. ASTM 82307 -04, Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intennediae- Scale, Multi -story Test Apparatus Additional Information: Type SAF mineral wool baits for use as a forming material for use in various Through- Penetration FireStop Systems, Joint Systems and Perimeter Fire Barrier Systems as Specified in UL's Fire Resistance Directory 'volume 2. Only those products bearing the UL Classification Marking should be considered as being covered by UL's Classification and Follow -Up Service. The liI. Classification Marking includes: UL in a circle symbol: V.V. with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UI.'s evaluation of the producr, and, the product category name (product identity) as indicated in the appropriate UL Directory. Engineer: \Iona Cauloute t'nderwriters Laboratories Inc. Review Engineer. Chris Johnson t'ndcrwriters Labo • Firestop Drop-In Device CFS -DID • • Features and Applications One -step firestop solution fora variety of pipe materials and diameters z Integrated moisture and smoke seal z Simple, quick and error free installation Easily identifiable to building inspectors a Solution for renovatioNretrofit as watt as new construction a Buy American compliant Deseriptker Drop -In Device CFS -DID 2° C For use with 6" to 12" thick concrete / metal deck Casa bit size 4" Qty 1 Pipe size up to 2" • item No :. ;C4 e _.. Drop -In Device CFS -DID 3° C 5" 1 3" _,..:.:z='s , r, Drop -In Device CFS -DID 4° C 6" 1 4 r;2 ^sic :'c Drop -in Device CFS -DID 6" C 9" 1 6" :,T4:47e,zir. Drop -in Device CFS -DID 2° MD 2 -1/1" to 8" thick concrete /metal deck 4" 1 up to 2" • ^,.'INJY? _ . Drop -In Device CFS -END 3° MD 5" 1 3" :'� 7;i7e :>.7:' Drop -In Device CFS -DID 4" tdID 6" 1 4" ._ ..... _ : : Drop -be Device CFS -DID 6" MD 9" 1 6" , 7 c Drop -In Device CFS -DID 2° HC8 7-1/2" to 8-1/2" thick hollow core 4" 1 up to 2" ' v= : ' f ;.. Drop -In Device CFS.DID 3° HMI 5 1 3" , . :`.1r.= Drop -In Device CFS -DID 4° HC8 6" 1 4° ,.... _.. _ Drop -In Device CFS -DID 2° HC10 9 -1 j2" to 10 -1/2" thick hollow core 4' 1 up to 2 "• :. _ _ .: ". Drop-in Device CFS -DID 3" 11C10 5 1 3" _ .. s. _ Drop-In Device CFS -DID 4° HCI0 6" 1 4" _. - ... _ _ .- Drop-In Device CFS -DID 2° HC12 11-1/2° to 12 -1/2" thick hollow core 4" 1 up to 2" • 7::'::.:•::.•:7:7,7, Drop-In Die CFS -DID 3" HC12 5" 1 3" -... _ _ ; . Drop-in Device CFS -DID 4" HC12 6" 1 4" .77.:.i.'::,;::: Adapter CPS-410r • Adapter to hold top seal plug in place • Adds 1" to the overall height All Drop-In Device sizes 2" 6 - - 'Far pipes smaller than 2•. use adapter and top seal plug Tested in accordance with ASTM E-814 • UL 1479 • CAN/tiLC -5115 Installation Instructions Device aind Adapter. Technical Data CFS -DID Expansion - 356°F (- 180°C) temperature Expansion rate 1:15 load expansion, load = 5g/cm3 1:40 free expansion Temperature -4° up to + 190°F resistance (20° up to +88°C) Storage temperature 23° up to 122°F ( -5° up to +50°C) CES -DID from above (no cap) CFS -DID from above (wfth cap) CFS -DID from bellow DD 2001 HD3D arcremcna 0 Outperfo i.,,x)_.)e Outlast. IL Hilti, Inc. (US.) 1400- 879 -8000 wntvw.0 a.tditicom • en espattol 1-800 -879 -5000 • Hilt (Canada) Corp. 1- 800-363 -4458 vvermilitd.ca • • • Product name: Description: Supplier: MATERIAL SAFETY DATASHEET CFS -DID Metal Firestop Insert containing a buck intumescent material. Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 (USA, PR, Virgin islands, Canada); INGREDIENTS AND EXPOSURE LIMITS MSDS No.: 335 Revision No.: 000 Revision Date: 04/18/11 Page: 1 of 2 (other countries) Not applicable. This product is considered to be an °article° as defined in the federal OSHA Hazard Communication Standard 29 CFR 1910.1200 1 1926.59. PHYSICAL. DATA Appearance: Vapor Density: (air =1) n PPInt Evaporailr Rate: Specific Gravity: Galvanized metal sleeve with red plastic top cap Not applicable. Not applicable. Not applicable. Not determined. Odor None. Vapor Prune: VOC Content Solubility its Water: pH: FIRE AND EXPLOSION HAZARD DATA Not applicable. 0.19 gll Not determined. Not applicable. Flash Point Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire and Explosion Hazards: Not applicable. Flammable Limits: _ Use extinguishing media appropriate for surrounding fire. None known. Not applicable. None known. Product serves as a fiiestop; intumescent material sleeve expands when exposed to temperatures > 160° C 1 320° F. REACTIVITY DATA Stability: incompatibility: Conditions to Avoid: Stable. None known. None known. Hazardous Polymerization: Will not occur. Decomposition Products: None known. HEALTH HAZARD DATA Known Hazards: Signs and Symptoms of Exposure: Carcinogenicity: Medical Conditions Aggravated by Exposure: None known. Routes of Exposure None known. None expected from routine use/installation according to manufacturer's specifications and technical guides. The endosed intumescent strip contains carbon black which has been classified by the IARC as 2B — °Possibly Carcinogenic to Humans'. This data is based on long term inhalation studies. As this product is used, no carbon black dust is present or produced, so this classification is not relevant None known. EMERGENCY AND FIRST AiD PROCEDURES Eyes: Skin: Inhalation: Ingestion: Other: Immediately flush with plenty of water. Call a physician if symptoms occur. Not applicable. Practice good hygiene; i.e. wash hands during breaks, before eating or smoking, and after work. Not applicable. Not a potential route of exposure. Referral to a physician is recommended if there is any question about the seriousness of any injury/exposure. HILTI ® is a registered trademark of Hilti Corp. • • • CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: Eye Profs for: Skin Protectlon: Respiratory Protection: Handling and Storing Precautions: Spill Procedures: Hazard Communication: DOT Shipping Name: IATPJICAO Shipping Name: TSCA Inventory: SARA Tide IIL Seen or f 313: EPA Vihtste Code(s): Waste Disposal Methods: General (natural or mechanically induced fresh air movements). Not required, however, safety glasses should be worn in most industrial settings. None required; however, gloves recommended. No respiratory protection is needed for normal application of This product PRECAUTIONS FOR SAFE HANDLING AND USE Store in a cool dry area. Follow installation instructions. No special requirements. . REGULATORY INFORMATION This product is considered to be an "article" as defined in the federal OSHA Hazard Communication Standard. Not regulated. Not regulated. Chemical components meted on TSCA inventory. This product is classified as an "article" and is not subject to reporting under Section 313 of SARA Trde 111(40 CFR Part 372). Not regulated by EPA as a hazardous waste. Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: Health l Safety: 1 800 879 8000 1 800 879 6000 Technical Seivlce: Jerry Metcalf (x1003704) (USA,. PR, Virgin Islands, Canada); 1 800 879 8000 (other countries) The information and recommendations contained herein are based upon data believed to be correct however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. MSDS 335, Page 2 of 2 Certificate Number 20110422-R15431 Reper: Reference 2011 April 22 Issue Date 2011 Aprll 22 ffmedip: Hilt inc. This i.5"1.41 Certify Char respre..,enorive samples of • 3.1.1 t • :4e .; : 5400 S 122ND East Ave Tulsa, OK 74146 Loto 1; Page 1°11 Firestop Devices CFS-DID for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. ta Cc 7tficate ANSULT 1479, "Fire Tests of Through-Penetration Firestops." CAN/ULC-S115-2005, "Standard Method of Fire Tests of Firestop Systems." See IJL On-Line Certification Directory at r 7 for additional information. Only Thos.,. products bearing t e I. C ;' cricru :Pr and Frxilow-Up Sery;c The UL Classification Mark includes. U.. 0 • UUcUL SYSTEM NO. F- 8-5005 INSULATED METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RATING = 0-HR. OR 2 -HR. TOP VIEW SECTION A A INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS 1. ANY UL CLASSIFIED PRECAST HOLLOW-CORE FLOOR ASSEMBLY (MINIMUM 6" TO MAXIMUM 12 -1/2" THICK) (3-HR. FIRE - RATING). 2. [OPTIONAL - NOT SHOWN] NOMINAL 4 ", 5", OR 6" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.), HAVING A MINIMUM 2" LAP ALONG TIIE LONGITUDINAL SEAM, INSERTED INTO THE OPENING. SLEEVE MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 2" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 2" NOMINAL DIAMETER COPPER PIPE OR TUBING. 4. ONE OF THE FOLLOWING PIPE COVERS TO BE USED : A. NOMINAL 3/4" OR 1" THICK AB/PVC PIPE INSULATION (SEE TABLE BELOW). B. NOMINAL 1" OR 1.1/2" THICK GLASS -FIBER PIPE INSULATION. 5. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILT! 1/4" (6mm) DIAMETER BY 1-1/4" (32mm) LONG KWIK -CON 11+ CONCRETE SCREW ANCHORS, HILT! 1/4" (6mm) DIAMETER BY 1-3/4" (45mm) LONG. KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILT1 1/4" (6mm) BY 314" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11/16" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAYBE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. NOM PIPE OR TUBE (ITEM 3) DIAM INSULATION TYPE (ITEM 4A OR 48) AND THICKNESS 1/2" 3/4" OR 1" AB/PVC 1" 2" 3/4" OR 1" AB/PVC 3/4" OR 1" AB/PVC CORE HOLE FIRESTOP DEVICE OR SLEEVE DIAM CFS -DID 2" C CFS -DID 3" C CFS -DID 4" C 4" 5" 6" Sheet Scale FLOOR THICKNESS (MIN. MAX.) 6" to 6-1/2" 6" to 6-1/2" 6" to 6-1/2" ilt1 Firestop Systems 7/64° =7- Date May 13, 2011 Saving Lives through Innovation and Education Drawing No. FB 5005a FB5005a.051311 UL/cUL SYSTEM NO. F- 8-5005 INSULATED METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. co m T- RATING = 0-HR. OR 2 -HR. LL NOM PIPE OR INSULATION TYPE TUBE (ITEM 3) (ITEM 4A OR 48) CORE HOLE DIAM AND THICKNESS FIRESTOP DEVICE OR SLEEVE DIAM 1/2" 1" GLASS FIBER CFS -DID 2" C 4" 1" 1" GLASS FIBER a Cf S -DID 3" C 5" 1" 1 -112" GLASS FIBER CFS -DID 4" C 6" FLOOR THICKNESS (MIN. MAX.) 6" to 6-1/2" 6" to 6 -112" 6 "to6.1/2" 2" 1" GLASS FIBER ! CFS -DID 4" C 1/2" 314" OR 1" AB/PVC CFS -DID 2" HC8 1" 3/4" OR 1" AB/PVC CFS -DID 3" HC8 2" 3/4" OR 1" AB/PVC CFS -DID 4" HC8 1/2" 1" GLASS FIBER CFS -DID 2" HC8 1" 1" GLASS FIBER CFS -DID 3" HC8 1" 1 -1/2" GLASS FIBER CFS -DID 4" HC8 6" 4" 5" 6" 4" 6" to 6-1/2" 7-1/2" to 84/2" 7-1/2" to 8-112" 7 -112" to 8-1/2" 74/2" to 8-1/2" 7 -112" to 8.1/2" 6" 7 -1/2" to 8 -112" 2" 1" GLASS FIBER CFS -DID 4" HC8 6" 7 -1/2" to 8-1/2" 1/2" 314" OR 1" AB /PVC CFS -DID 2" HC10 4" 3/4" OR 1" AB/PVC CFS -DID 3" HC10 5" 2" 3/4" OR 1" AB/PVC CFS-DID 4" HC10 6" 9 -112" to 10 -112" 9-112" to 10 -112" 9-112" to 10-1/2" 1/2" 1" 1" 2" 1" GLASS FIBER 1" GLASS FIBER 1 -1/2" GLASS FIBER - 1" GLASS FIBER CFS43ID 2" HC10 - CFS -DID 3" HC10 CFS -DID 4" HC10 CFS -DID 4" HC10 4" 5" 6" 9-112" to 10 -1/2" 9-112" to 10 -112" 9-1/2" to 10.1/2" 6" 9-112" to 10 -1/2" 112" . 314" OR? AB/PVC 1" 3/4" OR 1" AB/PVC 2" 3/4" OR 1" ABIPVC 112" 1" GLASS FIBER 1" 1" GLASS FIBER 1" 1 -112" GLASS FIBER 2" 1" GLASS FIBER CFS -DID 2" HC12 CFS -DID 3" HC12 CFS -DID 4" HC12 CFS -DID 2" HC12 CFS -DID 3" HC12 CFS -DID 4" HC12 CFS -DID 4" HC12 . 4" 11 -1/2" to 12.112" 5" 11 -112" to 12-1/2" 6" 11 -112" to 12-1/2" 4" 11 -1/2" to 12 -112" 5" 11-1/2" to 12412" 6" 11 -1/2" to 12-112" 6" 11 -112" to 12.112" HILTI, Inc. Tulsa, Oldahoma USA (800) 879-8000 lHilti Firestop Systems E Date May 13, 2011 Sheet 2 of 2 Scale Saving Lives through Innovation and Education Drawing No. FB 5005a ULIcUL SYSTEM NO. F- 8.5004 INSULATED METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T RATING = 0-HR. OR 2 -HR. A TOP VIEW Co w A INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 2 ", 3`, OR 4" DEVICES) 1. CONCRETE FLOOR ASSEMBLY (3-HR. FIRE - RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 6° TO 12" THICK). B. STEEL FLOOR UNIT /FLOOR ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 6" TO 12" THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). HILT!, Inc. Tulsa, Oldahoma USA (800) 879 -8000 iiti Firestop Systems j ° May 13, 2011 Saving Lives through Innovation and Education Sheet 1 of 2 Scale 11164" =1" Drawing No. FB 5004b ULIcUL SYSTEM NO. F- B-5004 INSULATED METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RATING = 0-HR. OR 2 -HR. 2. [OPTIONAL - NOT SHOWN] ANY OF THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID- HEIGHT OF SLEEVE AND SIZED MINIMUM 2" LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE.. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE OR TUBING. 4. ONE OF THE FOLLOWING PIPE COVERS TO BE USED : A. NOMINAL 3/4" OR 10 THICK AB/PVC PIPE INSULATION (SEE NOTE NOTES BELOW). B. NOMINAL 1 ",1 -112 °, OR 2" THICK GLASS-FIBER PIPE INSULATION. 5. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILTI 1/4" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK -CON II+ CONCRETE SCREW ANCHORS, HILT11 /4" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 114° (6mm) BY 3/4" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11/16" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. FB5004b.051311 NOMINAL PIPE DIAMETER INSULATION TYPE AND THICKNESS FIRESTOP DEVICE CORE HOLE OR SLEEVE DIAMETER 1/2" 3/4" OR 1" AB/PVC J CFS -DID 2" C 4" 1" 3/4" OR 1" AB/PVC 1 CFS -DID 3" C 5" 2" 314" OR 1" AB/PVC 1 CFS -DID 4" C 6" 4" 3/4" OR 1" AB/PVC 1 CFS -DID 6" C 1/2" 1" 1" GLASS -FIBER 1" GLASS -FIBER CFS -DID 2" C CFS -DID 3" C 4" 5" 1 1" 1 -1/2" GLASS -FIBER CFS -DID 4" C 6" 2" 1" GLASS -FIBER 1 CFS-WD 4" C 6" 2" 2" GLASS -FIBER CFS -DID 6" C 9" 4" 1" GLASS -FIBER CFS -DID 6° C k 9" NOTE : T- RATING 0-HR. WHEN SLEEVE IS USED. HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Hilt! Firestop Systems ,1 " °`u May 13,2011 Sheet 2 of 2 Scale Saving Lives through Innovation and Education Drawing No. FB 5004b UL SYSTEM NO. F- B-2050 PLASTIC PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING _ 3-HR. T RATING = 0-HR. OR 1/2 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) W RATING = CASS I (SEE NOTE NO. 2 BELOW) TOPS SECTION A-A INDICATES APPROXIMATE RECOMMENDED LOCA1ION OF X-GH FASTENERS 1. ANY UL CLASSIFIED PRECAST HOLLOW -CORE FLOOR ASSEMBLY (MINIMUM 6" TO MAXIMUM 12 -112" THICK) (3-HR. FIRE - RATING). 2. [OPTIONAL - NOT SHOWN] NOMINAL 4 ", 5", OR 6" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.), HAVING A MINIMUM 2" LAP ALONG THE LONGITUDINAL SEAM, INSERTED INTO THE OPENING. SLEEVE MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. FB2050a.051311 Hilts Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879-8000 Sheet 1 of 2 Scale N32- =1" Date May 13, 2011 Saving Lives through Innovation and Education Drawing No. FB 2050a UL SYSTEM NO. F-B -2050 PLASTIC PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY MATING = 3-HR. T- RATING = 0-HR. OR 112 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) W- RATING = CASS I (SEE NOTE NO. 2 BELOW) 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 4" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 4" NOMINAL DIAMETER CPVC PLASTIC PIPE. D. MAXIMUM 4" NOMINAL DIAMETER FRPP PLASTIC PIPE. 4. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILT1114" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK CON 11+ CONCRETE SCREW ANCHORS, HILTI 114" (6mm) DIAMETER BY 1314" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 1/4" (6mm) BY 314" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11116" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BEINSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. FB2050a.051311 CORE HOLE OR NOM DIAM OF SLEEVE DIAM FIRESTOP DEVICE THROUGH PENETRANT FLOOR THICKNESS (MIN. MAX.) 4" I CFS -DID 2" C 2" OR SMALLER+ 6" to 6 -112" 5" ) CFS -DID 3" C 3° 6" I CFS -DID 4" C 4" 6" to 6 -112" 6" to 6-1/2" 4" I CFS -DID 2° HC8 2° OR SMALLER+ 7 -112" to 8-1/2" 5" CFS -DID 3" HC8 • CFS -DID 4" HCS 3" 4" 7 -112" to 8-1/2" 7 -112" to 8-112" 4" CFS -DID 2" HC10 2" OR SMALLER+ 9 -112" to 10 -1/2" 5" 6" 4" CFS -DID HC10 CFS -DID 4" HC10 CFS -DID 2" HC12 3" 4" 2" OR SMALLER+ 9-112" to 10 -.1/2" 9-1/2" to 10 -1/2" 11 -1/2" to 12 -1/2" 5" CFS -l.''s 3" HC12 6" CFS -DID 4" HC12 4" 11 -1/2" to 12.112" 11 -112° to 12-1/2" + FOR PIPE SMALLER THAN NOMINAL 2° DIAMETER, AN ADAPTER AND HILT/ IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" C, HCB, HC10, AND HC12 DEVICES. NOTES ;1. CLOSED OR VENTED PIPING SYSTEM (PVC, ABS, FRPP = SCH 40; CPVC SDR 13.5). 2. [OPTIONAL] TO ACHIEVE W- RATING AND /OR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 ", 3 ", AND 4" PIPES (LISTED ABOVE). 1 of 2 Scale I -lilts Firestop Systems Drawing No. 5132" =1° FB Date May 13, 2011 2050a Saving Lives through Innovation and Education UL SYSTEM NO. F- 8-2048 PLASTIC PIPE THROUGH CONCRETE FLOOR ASSEMBLY MATING = 3-HR. T RATING = 0-HR. OR 112 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) W- RATING = CASS I (SEE NOTE NO.2 BELOW) TOP VIEW A A FB2048b.51311 INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 2 ", 3", OR 4" DEVICES) HILTI, Inc. Tulsa, Oldahoma USA (800) 879-8000 Sheet 1 of 2 Scale 11164" =1" Hilt! Firestop Systems Date May 13, 2011 Saving Lives through Innovation and Education Drawing No. FB 2048b UL SYSTEM Na F- B-2048 PLASTIC PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RATING = 0-HR. OR 1 /2 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) W- RATING = CASS I (SEE NOTE NO. 2 BELOW) 1. CONCRETE FLOOR ASSEMBLY (3-HR. FIRE- RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 6° TO 12" THICK). B. STEEL FLOOR UNIT/FLOOR ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 6 TO 12" THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). 2. [OPTIONAL - NOT SHOWN] ANY OF-THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID- HEIGHT OF SLEEVE AND SIZED MINIMUM 2" LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR-AND-VT FLUSH WITH TOP SURFACE OF FLOQR. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 6" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SO CORE). B. MAXIMUM 6" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 6" NOMINAL DIAMETER CPVC PLASTIC PIPE. D. MAXIMUM 6" NOMINAL DIAMETER FRPP PLASTIC PIPE. 4. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILTI 114" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIKCON II+ lip CONCRETE SCREW ANCHORS, HILTI 114" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 1I4" (6mm) BY 3/4" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11116" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. FB2048b.51311 CORE HOLE OR SLEEVE DIAMETER 4" PRODUCT I NOMINAL PIPE DESCRIPTION DIAMETER CFS -DID 2" C 2" (OR SMALLER)+ 5" CFS -DID 3" C 3" 6" CFS -DID 4" C 4" 9" CFS -DID 6" C 6" + FOR PIPE SMALLER THAN NOMINAL 2" DIAMETER, AN ADAPTER AND HILTI IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" C DEVICE. NOTES :1. CLOSED OR VENTED PIPING SYSTEM (PVC, ABS, FRPP o SCH 40; CPVC = SDR 13.5). 2. [OPTIONAL] TO ACHIEVE W- RATING ANDIOR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 ", 3 ", 4 ", AND 6" PIPES (LISTED ABOVE). Hllti Firestop Systems Saving Lives through innovation and Education HILTI, Inc. Tulsa, Oldahoma USA (800) 879 - 8000 sheet Scale Date 2 of 2 May 13, 2011 Drawing No. FB 2048b ULIcUL SYSTEM NO. F- 8-1029 METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RATING = 0-HR. OR 1/4 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFM/SQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F _ LESS THAN 1 CFM/SQ. FT. (SEE NOTE BELOW) W- RATING = CLASS I (SEE NOTE BELOW) TOP VIEW SECTION A -A A INDICATES APPROXIMATE RECOMMENDED LOCATION OFX -GH FASTENERS 1. ANY UL CLASSIFIED PRECAST HOLLOW -CORE FLOOR ASSEMBLY (MINIMUM 6" TO MAXIMUM 12 -1/2" THICK) (3-HR. FIRE - RATING). 2. [OPTIONAL - NOT SHOWN] NOMINAL 4 ", 5 ", OR 6" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.), HAVING A MINIMUM 2" LAP ALONG THE LONGITUDINAL SEAM, INSERTED INTO THE OPENING. SLEEVE MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. HILT!, Inc. Tulsa, Oklahoma USA (800) 879-8000 5132° =1" Hiiti Firestop Systems May 13, 2011 Drawing No. FB 1029a Saving Lives through innovation and Education ULIcUL SYSTEM NO. F- 8-1029 METAL PIPE THROUGH HOLLOW -CORE CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RATING = 0-HR. OR 1 /4-HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F = LESS THAN 1 CFM/SQ. FT. (SEE NOTE BELOW) W- RATING = CLASS I (SEE NOTE BELOW) 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE OR TUBING. D. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT OR EMT. 4. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILT! 1/4" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK -CON 0+ CONCRETE SCREW ANCHORS, HILTI 1 /4" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILT! 114" (6mm) BY 3/4" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FORNOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11116" (18mm) LONG HILT! X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. CORE HOLE OR SLEEVE DIAM FIRESTOP DEVICE 4" I CFS -DID 2" C 5" CFS -DID 3" C NOM DIAM OF THROUGH PENETRANT FLOOR THICKNESS (MIN. MAX.) 2" OR SMALLER+ 6 "to6 -112" 3" 6° to 6 -112" 6" CFS -DID 4" C. 4" CFS -DID 2° HC8 CFS-DID 3" HC8 4" 2" OR SMALLER+ 6" to 6-112" 7 -112" to 8-1/2" 3" 7 -112" to 8-1/2" CFS -DID 4" HC8 4" 7 -1/2" to 8-1/2" 4" CFS -DID 2" HC10 5" CFS -DID 3" HC10 2" OR SMALLER+ 3" 9-112" to 10 -1/2" 9.1/2" to 10 -1/2" 6" CFS -DID 4" HC10 4" 9-112" to 10 -1/2" 4" CFS -DID 2" HC12 2" OR SMALLER+ 11.112" to 12.112" 5" CFS -DID 3" HC12 3" 11 -112" to 12 -1/2" 6" CFS -DID 4" HC12 4" 11 -112" to 12 -1/2" + FOR PIPE SMALLER THAN NOMINAL 2" DIAMETER, AN ADAPTER AND HILTI IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" C, HCS, HC10, AND HC12 DEVICES. NOTE : [OPTIONAL] TO ACHIEVE W- RATING AND /OR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 ", 3 ", AND 4" PIPES (LISTED ABOVE). Hilti Firestop Systems HILTI, Inc. Tulsa, OIdahoma USA (800) 879-8000 Sheet Scale Date Saving Lives through Innovation and Education 2 of 2 Drawing Na FB May 1 3 , 2 0 1 1 0 1029a UUcUL SYSTEM NO. F-B -1026 METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T RATING = 0-HR. OR 1I4 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F = LESS -THAN 1 CFMISQ. FT. (SEE NOTE BELOW) W RATING = CLASS I (SEE NOTE BELOW) TOP VIEW A A FB1026b.051311 INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 2', 3°, OR 4" DEVICES) Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879-8000 Sheet 1 of 2 Scale 11164" 1" De Saving Lives through Innovation and Education May 13, 2011 Dreehng Na FB 1026b UL/cUL SYSTEM NO. F- 8-1026 METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 3-HR. T- RA11NG = 0-HR. OR 1 /4-HR. L- RATING AT AMBIENT = LESS THAN 1 CFM/SQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) W- RATING = CLASS I (SEE NOTE BELOW) 1. CONCRETE FLOOR ASSEMBLY (3-HR. FIRE - RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 6" TO 12" THICK). B. STEEL FLOOR UNIT/FLOOR ASSEMBLY • LIGHTWEIGHT OR NORMAL. WEIGHT CONCRETE FLOOR (MINIMUM 6 TO 12" THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). 2. [OPTIONAL - NOT SHOWN] ANY OF THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID - HEIGHT OF SLEEVE AND SIZED MINIMUM 2" LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE-CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING A. MAXIMUM 6" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 6" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE OR TUBING. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILTI 1/4" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK -CON II+ CONCRETE SCREW ANCHORS, HILTI 114" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 114" (6mm) BY 3/4" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11/16" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. CORE HOLE OR SLEEVE DIAMETER PRODUCT DESCRIPTION NOMINAL PIPE DIAMETER 4" CFS -DID 2" C 2" (OR SMALLER)+ 5° CFS -DID 3" C 3" 6" CFS -DID 4" C 4" 9" CFS-D(D 6" C 6" + FOR PIPE SMALLER THAN NOMINAL 2" DIAMETER, AM ADAPTER AND HILT, IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" C DEVICE NOTE : [OPTIONAL] TO ACHIEVE W- RATING AND /OR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 ", 3 ", 4 ", AND 6" PIPES (LISTED ABOVE). Data May 13, 2011 Saving Lives through Innovation and Education Drawing No. FB 1026b UL1cUL SYSTEM NO. F -A 5046 INSULATED METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. OR 3-HR. T- RATING = 0-HR. OR 112 -HR. A TOP VIEW A INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 2 °, 3° OR 4° DEVICES) 1. CONCRETE FLOOR ASSEMBLY (2-HR. OR 3-HR. FIRE- RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2.112" TO 8" THICK). B. STEEL FLOOR UNIT/FLOOR ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2 -112" TO 8" THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). HILTI, Inc. Tulsa, Oldahama USA (800) 879.8000 Sheet 1 of 2 Scale Hilts Firestop Systems ` May 13,2011 Saving Lives through Innovation and Education Drawing No. FA 5046b UUcUL SYSTEM NO. F- A-5046 INSULATED METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2-HR. OR 3-HR. T- RATING = 0-HR. OR 112 -HR. 2. [OPTIONAL - NOT SHOWN] ANY OF THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID- HEIGHT OF SLEEVE AND SIZED MINIMUM 2" LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE OR TUBING. 4. ONE OF THE FOLLOWING PIPE COVERS TO BE USED : A. NOMINAL 314" OR 1" THICK AB/PVC PIPE INSULATION (SEE NOTE NOTES BELOW). B. NOMINAL 1", 1-1/2", OR 2" THICK GLASS -FIBER PIPE INSULATION. 5. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILTI 114" (6mm) DIAMETER BY 1 -1/4" (32mm) LONG KWIK -CON 11+ CONCRETE SCREW ANCHORS, HILTI 1/4" (6mm) DIAMETER BY 1-314" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 1/4" (6mm) BY 314" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2", 3 ", AND 4" DEVICES, FOUR 11116" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. NOMINAL PIPE DIAMETER 112" 1" 2" 4" 1/2" 1" 1" 2" 2" 4" INSULATION TYPE AND THICKNESS 314" OR 1" AB/PVC 3/4" OR 1" AB/PVC 3/4" OR 1" AB/PVC 3/4" OR 1" AB/PVC 1" GLASS -FIBER 1" GLASS -FIBER 1.1/2" GLASS -FIBER 1" GLASS -FIBER 2" GLASS -FIBER 1" GLASS -FIBER FIRESTOP DEVICE CFS -DID 2" MD CFS -DID 3" MD CFS -DID 4" MD CFS -DID 6" MD CFS-DID 2" MD CORE HOLE OR SLEEVE DIAMETER 4" 5" 6" 9" CFS -DID 3" MD CFS -DID 4" MD CFS -DID 4" MD CFS-DID 6" MD 4" 5" 6" 9" 1 CFS -DID 6" MD 9" NOTE : T- RATING = 0-HR. WHEN SLEEVE IS USED. I. Hilti Firestop Systems HILTI, Inc. Tulsa, aidahoma USA (800) 879 -8000 Saving Lives through Innovation and Education Drawing No. FA 5046b UL SYSTEM NO. F-A -2213 PLASTIC PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. OR 3-HR. T- RATING = 0-HR. OR 112 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) W RATING = CLASS 1 (SEE NOTE NO. 2 BELOW) TO VIEW SECTION A-A INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 21', r, OR 4" DEVICES) FA2213b.051311 1. CONCRETE FLOOR ASSEMBLY (2-HR. OR 3-HR. FIRE-RATING) : A. UGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2 -112" TO 8" THICK). B. STEEL FLOOR UNIT/FLOOR ASSEMBLY - UGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2.112" TO 8" THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). 2. [OPTIONAL - NOT SHOWN] ANY OF THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID - HEIGHT OF SLEEVE AND SIZED MINIMUM 2" LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. HiItI Flrestop Systems HILT!, Inc. Tulsa, Oklahoma USA (800) 879-8 Sheet 1 of 2 It Drawing No. Scale 5132" =1" FA Dare May 13, 2011 2213b Saving Lives through Innovation and Education UL SYSTEM NO. F -A 2213 PLASTIC PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. OR 3-HR. T- RATING = 0-HR. OR 1/2 -HR. L- RATING AT AMBIENT m LESS THAN 1 CFMISQ. FT. (SEE NOTE NO. 2 BELOW) L- RATING AT 400 °F = LESS THAN 1 CFM /SQ. FT. (SEE NOTE NO. 2 BELOW) VIBRATING = CLASS I (SEE NOTE NO. 2 BELOW) 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 6" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 6" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). C. MAXIMUM 6" NOMINAL DIAMETER CPVC PLASTIC PIPE. D. MAXIMUM 6" NOMINAL DIAMETER FRPP PLASTIC PIPE. 4. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE HILTI 114" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK -CON II+ CONCRETE SCREW ANCHORS, HILTI 1/4" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 1/4" (6mm) BY 3/4" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" DEVICES, FOUR 11/16" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. MINIMUM CONCRETE THICKNESS CORE HOLE OR SLEEVE DIAMETER PRODUCT DESCRIPTION NOMINAL PIPE DIAMETER F- RATING 2 -112" 4" CFS -DID 2" MD 2 ■112" 5° CFS -DID 3" MD 2" (OR SMALLER)+ 3" 2 -HR. 2 -HR. 2-1/2" 2.1/2° 9° CFS-DID 4" MD CFS -DID 6" MD 6" 2 -HR. 2 -HR. 4-1/2" 4" CFS -DID 2" MD 4-1/2" 5" CFS -DID 3° MD 2" (OR SMALLER)+ 3-HR. 3" 3-HR. 4-112" 6" CFS -DID 4" MD 4" 3-HR. 4-1/2" 9" CFS -DID 6" MD 6" 3-HR. + FOR PIPE SMALLER THAN NOMINAL 2" DIAMETER, AN ADAPTER AND HILT! IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" MD DEVICE. NOTES : 1. CLOSED OR VENTED PIPING SYSTEM (PVC, ABS, FRPP = SCH 40; CPVC = SDR 13.5). 2. [OPTIONAL] TO ACHIEVE W- RATING ANDIOR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 ", 3 ", 4 ", AND 6" PIPES (LISTED ABOVE). Hilts Flrestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879-8000 Sheet Scale Date Saving Lives through Innovation and Education 2 of 2 Drawing Na FA May 13, 2011 112213b UUcUL SYSTEM NO. F -A -1128 METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. OR 3-HR. T RATING = 0-HR. OR 114 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) W-RATING = CLASS I (SEE NOTE BELOW) TOP SECTION A-A INDICATES APPROXIMATE RECOMMENDED LOCATION OF X-GH FASTENERS (WHEN USED ON 2; 3" OR 4" DEVICES) FA1128b.051311 1. CONCRETE FLOOR ASSEMBLY (2-HR. OR 3-HR. FIRE - RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2 -112" TO 8" THICK). B. STEEL FLOOR UNIT/FLOOR ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2-1/2" TO 8° THICK) OVER METAL DECKING (UL CLASSIFIED D700, D800, OR D900 SERIES). 2. [OPTIONAL - NOT SHOWN] ANY OF THE FOLLOWING SLEEVES MAY BE USED : A. NOMINAL 4 ", 5 ", OR 6" DIAMETER STEEL PIPE SLEEVE (SCHEDULE 10 OR HEAVIER) CAST OR GROUTED INTO FLOOR ASSEMBLY, FLUSH WITH FLOOR SURFACES. B. NOMINAL 4 ", 5 ", 6 ", OR 9" DIAMETER GALVANIZED STEEL SLEEVE (MIN. 26 GA.) WITH SQUARE FLANGE SPOT WELDED TO BOTTOM OR MID - HEIGHT OF SLEEVE AND SIZED MINIMUM 2° LARGER THAN SLEEVE DIAMETER. SLEEVE IS TO BE CAST IN PLACE, AND MAY EXTEND A MAXIMUM 4" BELOW BOTTOM SURFACE OF FLOOR AND SIT FLUSH WITH TOP SURFACE OF FLOOR. HILT!, Inc. Tulsa, Oklahoma USA (800) 879--8000 Sheer sure Deb 1 of 2 Drawing Na 5132 " =1 - FA May 13, 2011 '1128b Saving Lives through Innovation and Education UUcUL SYSTEM NO. F -A -1128 METAL PIPE THROUGH CONCRETE FLOOR ASSEMBLY F- RATING = 2 -HR. OR 3-HR. T- RATING = 0-HR. OR 114 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. (SEE NOTE BELOW) L- RATING AT 400 °F = LESS THAN 1 CFM/SQ. FT. (SEE NOTE BELOW) IN- RATING = CLASS I (SEE NOTE BELOW) 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 6" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 6" NOMINAL DIAMETER CAST OR DUCTILE IRON P E. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE OR TUBING. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 4. HILTI CFS -DID FIRESTOP DROP -IN DEVICE INSERTED INTO OPENING (SEE TABLE BELOW) AND SECURED TO TOP OF FLOOR WITH THREE Him 114" (6mm) DIAMETER BY 1 -114" (32mm) LONG KWIK-CON 11+ CONCRETE SCREW ANCHORS, HILTI 1/4" (6mm) DIAMETER BY 1-3/4" (45mm) LONG KWIK BOLT 3 STEEL EXPANSION ANCHORS, OR HILTI 1/4" (6mm) BY 314" (19mm) LONG METAL HIT ANCHORS (INSTALLED IN A TRIANGULAR FASHION THROUGH HOLES PROVIDED). IN ADDITION, FOR NOMINAL 2 ", 3 ", AND 4" •DEVICES, FOUR 11116" (18mm) LONG HILTI X-GH P18 MX STEEL FASTENERS MAY BE INSTALLED THROUGH THE STEEL FLANGE, TWO ON EACH SIDE. MINIMUM CONCRETE THICKNESS CORE HOLE OR PRODUCT SLEEVE DIAMETER DESCRIPTION 2.112" 2-1/2" 2 -1/2" 2 -1/2" 41/2" 41/2° 41/2" 4112" 4" 5" 9" 4" NOMINAL PIPE DIAMETER F- RATING CFS -DID 2" MD 2° (OR SMALLER)+ CFS -DID 3" MD 3" CFS -DID 4" MD CFS -DID 6" MD CFS -DID 2" MD 5" CFS -DID 3" MD 6" CFS -DID 4" MD S" CFS -DID 6" MD 4" 6" 2" (OR SMALLER)+ 30 4" 6" 2 -HR. 2 -HR. 2 -HR. 2 -HR. 3-HR. 3-HR. 3-HR. 3-HR. + FOR PIPE SMALLER THAN NOMINAL 211 DIAMETER, AN ADAPTER AND HILT! IPS OR CPS TOP SEAL PLUG MUST BE USED IN CONJUNCTION WITH THE CFS -DID 2" MD DEVICE FA1128b.051311 NOTE : [OPTIONAL] TO ACHIEVE W RATING AND /OR L- RATING, WATER BARRIER MODULES MAY BE THREADED ON TOP OF CFS -DID DEVICES FOR NOMINAL 2 °, 3 ", 4 ", AND 6" PIPES (LISTED ABOVE). iiti Firestop Systems HILT!, Inc. Tulsa, Oklahoma USA (800) 879 -8000 May 13, 2011 Drawing No. FA 1128b Saving Lives through Innovation and Education Mechanical naril Hilt,. Outperform OuitIist CONCRETE FLOOR / CONCRETE & MASONRY WALL Blank Opening Metal Pipe Non - Metallic Pipes / Conduits CAJ -5198 CAJ-5069 Cable Bundle or Cable Tray Insulated Metal Pipe Electrical Busway Sheet Metal Duct Multiple Penetrations Barry University Residence Hall Revised: 11/21/2011 U.L. Firestop Systems Chart JOINT SYSTEMS CONCRETE WALL CURTAIN WALL 5 - Systems 0 -EJs GYPSUM WALL Blank Opening Metal Pipe Non- Metallic Pipes / Conduits Cable Bundle or Cable Tray Insulated Metal Pipe Electrical Busway WL -5028 WL -5046 Sheet Metal Duct Multiple Penetrations WL -7042 UUcULLSYSTEM NO. C -AJ -5198 INSULATED METAL PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL ASSEMBLY 'PRATING = 2 -HR.. ;;. T- RATING = 0 -HR. OR 112 -HR. 1. CONCRETE FLOOR OR WALL ASSEMBLY (2 -HR. FIRE - RATING) : A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR (MINIMUM 2 -112" THICK). B. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE WALL (MINIMUM 3" THICK). C. ANY UL1cUL CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. 3. MINIMUM 112" TO MAXIMUM 314" THICK ABIPVC PIPE INSULATION. 4. MINIMUM 2" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED. 5. MINIMUM 112" DEPTH HILTI FS-ONE HIGH PERFORMANCE INTUMESCENT FIRESTOP SEALANT. 6. MINIMUM 112" BEAD HILTI FS -ONE HIGH PERFORMANCE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. NOTES :1. MAXIMUM DIAMETER OF OPENING 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1-318". 3. MINIMUM 1/2" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT IS REQUIRED ON BOTH SIDES OF A WALL ASSEMBLY. 0 0) Hiltl Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (800) 879 -8000 Sheet 1011 Scale 114 " =1" Date June 12, 2008 Drawing No. CAJ 5198b Saving Lives through Innovation and Education • UUcUL SYSTEM NO. C -AJ -5069 INSULATED METAL PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL F- RATING = 2 -HR. 7- RATING =0 -HR. AND 1-HR. TOP VIEW SECTION A -A A 1. CONCRETE FLOOR OR WALL ASSEMBLY (2 -HR FIRE - RATING): A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR OR WALL (MIN. 4-1/2" THICK). B. ANY UUULC CLASSSIFIED CONCRETE BLOCK WALL. 2. OPTIONAL : MAXIMUM 22" NOMINAL DIAMETER STEEL PIPE SLEEVE (SCHEDULE 40). 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 12" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 40 OR HEAVIER). B. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. 4. FOAMGLASS® PIPE INSULATION (1.1/2" TO 3" THICKNESS). 5. MINIMUM 12" LONG JACKET FORMED OF MINIMUM 0.010" THICKNESS STEEL OR ALUMINUM SHEET SECURED IN PLACE WITH 2 STEEL BAND CLAMPS. ENDS OF JACKET TO OVERLAP BY A MINIMUM 2 ". 6. MINIMUM 3" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED, 7. MINIMUM 314" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. NOTES : 1. ANNULAR SPACE = MINIMUM 3/4 ", MAXIMUM 3 ". 2. MINIMUM 3/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AND SHEET METAL JACKET ARE REQUIRED ON BOTH SIDES OF A WALL ASSEMBLY. U[ h1J—E1° FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 3132 " =1" Date August 31, 1999 Saving Lives through Innovation and Education.:::. Drawing No. CAJ 5069g • ULIcUL SYSTEM NO. W-L-5028 INSULATED METAL PIPE THROUGH GYPSUM WALL ASSEMBLY F- RATING = 1-HR. OR 2 -HR. T RATING =314 -HR... L- RATING AT AMBIENT =1 CFM!SQ. FT. 1- RATING AT 400 °F =1,CFMISQ. FT. FRONT VIEW 1. GYPSUM WALL ASSEMBLY (ULIcUL CLASSIFIED 0300 OR U400 SERIES) (1-HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). 2. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 2.112" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 40 OR HEAVIER). B. MAXIMUM 2" NOMINAL DIAMETER COPPER PIPE OR TUBING, 4. NOMINAL 3/4" THICK AB/PVC FLEXIBLE FOAM PIPE INSULATION. 5. MINIMUM 518" DEPTH HILTI FS -ONE HIGH PERFORMANCE INTUMESCENT FIRESTOP SEALANT. 6. MINIMUM 1/2" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES :1. MAXIMUM DIAMETER OF OPENING = 7 -1I2 ". 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 1 -1/2 ". • Hilti Firestop Systems HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 5/32" =1" Dale Mar. 22, 2006 Saving Lives through Innovation and Education::. Drawing No. WL 5028j ULIcUL SYSTEM NO. W -L -5046 INSULATED METAL PIPE THROUGH A SLEEVE IN GYPSUM WALL ASSEMBLY F- RATING -1 AND 2 -HR. -RATING = O.AND 1 -HR, (SEE UL DIRECTORY, VOLUME II) 1. GYPSUM WALL ASSEMBLY (ULIULC CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR SHOWN). 2. MAXIMUM 22" NOMINAL DIAMETER STEEL PIPE SLEEVE (SCHEDULE 40 OR THINNER). 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 12" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 40 OR HEAVIER). B. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. 4. FOAMGLASS PIPE INSULATION (1 »112" TO 3" THICK). 5. MINIMUM 12" LONG JACKET FORMED OF MINIMUM 0.010" THICKNESS STEEL OR ALUMINUM SHEET SECURED IN PLACE WITH 2 STEEL BAND CLAMPS. ENDS OF THE JACKET TO OVERLAP BY A MINIMUM 2 ". 6. MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED (SEE NOTE NO. 3 BELOW). 7. MINIMUM 3/4" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. NOTES :1. MAXIMUM DIAMETER OF OPENING = 22 ". 2. ANNULAR SPACE = MINIMUM 3/4", MAXIMUM 3 ". 3. MINIMUM 2 -114" OR 3-112" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) REQUIRED FOR 1 -HR. OR 2 -HR. WALLS, RESPECTIVELY. WL5046h.091699 FIRESTOP SYSTEMS HILTI, Inc. Tulsa, Oklahoma USA (918) 252 -6000 Sheet 1 of 1 Scale 3/32' a 1" Date SEPT. 16,1999 Drawing No. WL 5046h Saving Lives through innovation and Education :l tic r-5 1r System; No. W -L -7042 F Ratings -- Land 2 Hr (See Items 1 and 3) T. Rating -- 0 Hr • • SECTION A A 1. Wall Assembly -- The 1 or 2 hr fire rated wallboard /stud wail assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs In the UL Fire Resistance Directory and shall include the following construction features. A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 In. lumber spaced 16 In. OC. Steel studs to be min 2 -1/2 In. wide and spaced 24 in. OC. B. Gypsum Board* -- For 1 hr assembly, one layer of min 5/8 in. thick wallboard as required in the individual Wall and Partition Design. For 2 hr. •,.; assembly, two layers of min 5/8 in. thick wallboard as required In the Individual Wall and Partition Design. Max dlam of opening is 14.1/2 In. for wood stud walls and 21 -3/4 for steel stud walls. The hourly F and T Ratings of the ttrestop system is equal to the hourly fire rating of the wall assembly in which it Is installed. 2. Through Penetrant -- Galy steel duct to be installed concentrically or eccentrically within the firestop system. The annular space between the duct and periphery of opening shall be 0 €n. (point contact) and max 1 -112 In. Duct to be rigidly supported on both sides of wail assembly. A. Spiral Wound HVAC Duct — Nom 20 in. dlam (or smaller) No. 24 MSG (or heavier) galv steel spriral wound duct. B. Sheet Metal Duct — Nom 121n. dlam (or smaller) No. 28 MSG (or heavier) gaiv sheet steel duct. 3. F111, Void or Cavity Material * - Sealant -- Mtn 5/8 In. and 1.1/4 In. thlckness of fill material applied within annulus, flush with both surfaces of wall assembly for 1 or 2 hr rated wails, respectively. At the point contact location between duct and wallboard, a min 1/2 In. diam bead of sealant shall.. be applied at the wallboard/duct Interface on both surfaces dwell assembly. HILT! CONSTRUCTION CHEMICALS, DIV OF HILT! INC — CP601 S Etastomeric Firestop Sealant, FS -ONE Sealant or CP806 Flexible Flrestop Sealant 'Bearing the UL Classification Mark 101111.111" Hilt. :Fires #op Systems • Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. November 30, 2000 • Electrical w • • SJONDESIGN SUBMITTAL IDENTIFICATION SHEET To be completed by ContractortCM Project Name /Address/Number Barry University Residence Hail 11300 NE 2nd Ave Miami Shores, FL 33161 Cannon Design Project No. 03617.00 Owner Barry University Architect / Engineer Cannon Design Submitted By Sunshine State Electric Contractor / CM Submittal No. 237 Cannon Design Submittal No. Drawing / Detail Reference Manufacturer / Supplier Hilti Priority. ❑ Critical Specification Section / Paragraph 07 84 13 Item! Product ID Fire Stoping Grout System Required Date: February 3, 2012 Remarks or Deviations Contractor / CM Certification (submittals not certified wilt be returned without review) CONSTRUCTION MANAGER MOSS & ASSOCIATES, LLC Derry University Residence Hall • Job No 2010023 SubieitW No. L7 ,.Reviewed • .__,.Reviewed as Noted - Reed It ®Reviewed as Noted • Not Approved - Restit>adt Reese days suteisdis real mimeo I* Mal regdreexsts. is ?s asib For dieauians, eleittin 8 ccortimtioa with ea tai Appeal' Oas col retest Sulicet e:twModce of hit = : to p/f .,< met tie „r : *am* Sy: Y- j?atnvNN9 Date: - —ir I Z J. Ramunno February 2, 2012 Reviewed by Date To be completed by Reviewer Cannon Design Submittal Number and Receive Date Requirements for Submission to Cannon Design Shop Drawings: Product Data: Samples: No Exceptions Taken No further review of submittal Is required. Make Correction Noted Incorporate corrections in work; resubmission is not required unless othetwlse noted. ❑ c. Revise and Resubmit Revise as noted, and resubmit for further review. ❑ D. Rejected Submittal not in compliance with Contract Documents. ❑ E. For Record Only Received for record purposes only. Review is for conformance with the design concept of this project and for general compliance with contract documents. Contractor is responsible for quantities, dimensions and compliance with contract documents and for information that pertains to fabrication processes, construction techniques and coordination of this work with ell trades which will be affected thereby. This review is null and void if submittal deviates from contract documents and does not indicate or note deviations. AIE Comments z *z.iz Reviewed by Date MOSS • Moss & Associates, LLC 2101 N Andrews Avenue 300 Ft Lauderdale FL 33311 TRANSMITTAL No 000237 PROJECT: Barry University Residence Hall TO: Cannon Design 1100 Wilson Blvd. Suite 2900 Arlington VA 22209 ATTN: Peter Mendota DATE: 02/02/2012 RE: Electrical Room Slab Fire Stopping Product Data JOB: 2010023 WE ARE SENDING: SUBMITTED FOR: ACTION TAKEN: Shop Drawings 1,/i Approval I I Approved as Submitted (� Letter n Your Use ri Approved as Noted Prints As Requested Returned After Loan Change Order Review and Comment I Resubmit Plans f Submit Samples SENT VIA: Attached —Separate Cover Retumed Returned for Corrections Specifications 1 Other Product Data Hand Delivered J Due Date: 10/20/2011 Other. Line Item Package Code Rev. Qty Date Description Status 1 Submittal • REMARKS: CC: • 000274 1 02/02/2012 Electrical Room Slab Fire Stopping Reviewed by GC Product Data Signed: Jason Ramunno • • System No. C -BJ -1049 F Rating — 2 Hr TRating — OHr SECTION A -A 1. Floor or Wall Assembly — Min 8 In. thick reinforced lightweight or normal weight 100-150 pciconcrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max area of opening is 528 sq in. with max dimension of 66 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants — One or more pipes, conduit or tubing to be installed within the firestop system. Min clearance between pipes, conduits or tubing is min 1/2 in. to max 12 in. Clearance between pipes, conduit or tubing and periphery of through opening is min 1/2 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used: A. Steel Pipe — Nom 4 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. — ABC B. Iron Pipe — Nom 4 in. diam (or smaller) cast or ductile iron pipe. C. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit 3. Forms — (Not Shown) — Used as a form to prevent leakage of fill material during installation. Forms to be a rigid sheet material, cut to fit the contour of the penetrating item and positioned as required to accommodate the required thickness of fill material. Forms may be removed after fill material has cured. 4. Fill, Void or Cavity Material* — Mortar — Min 2 -1/2 in. thickness of fill material applied within the annulus flush with top surface of floor or one surface of wail. Fill material is mixed at a rate of 2.5 parts dry mix to one part water by weight in accordance with the installation instructions supplied with fill material. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — Type CP637 *Bearing the UL Classification Mark !IP TL.FLr FIRESTOP SYSTEMS Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. May 13, 2003 This is a typical detail for a penetration through a concrete floor where the hole is cored for up to 3" PVC. System No. C—AJ-21 68 F Rating — 3 Hr T Rating — 0 Hr SECTION A —A 1. Floor or Wall Assembly — Min 4-1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 5 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Nonmetallic Pipe — Nom 3 in. diam (or smaller) Schedule 40 polyvinyl chloride (PVC) pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. One pipe to be installed either concen- trically or eccentrically within the firestop system. The annular space shall be min 1/2 in. to a max 1 in. Pipe to be rigidly supported on both sides of floor or wall assembly. 3. Fill, Void or Cavity Material* — Sealant — Min 4 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. HIL11 CONSTRUCTION CHEMICALS, DIV OF HILTI, Inc. — FS —ONE Sealant *Bearing the UL Classification Marking ors a• FIRESTOP SYSTEMS Reproduced by H ILll, Inc. Courtesy of Underwriters Laboratories, Inc. May 07, 1998 This is a typical detail for a penetration through a concrete floor where the hole is cored for up to 4" EMT. System No. C -AJ -1149 F Rating -- 2 Hr T Rating -- O Hr Rating At Ambient -- Less Than 1 CFM/sq ft L RatingAt400 F-- 4CFM /sgft W Rating -- Class I (See Item 4) 4 SECTION A -A 1. Floor or Wall Assembly — Min 4-1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 12 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants — One metallic pipe, conduit or tubing to be installed within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The annular space shall be 0 in. (point contact) to max 1 -1/4 in. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe — Nom 10 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 10 in. diam (or smaller) cast or ductile iron pipe. C. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit. D. Copper Tubing — Nom 4 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe — Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. 3. Packing Material — Min 3 in. thickness of min 4 pcf mineral wool batt insulation for nom 4 in. diam (and smaller) pipes, conduits or tubings and a min 4 in. thickness of min 4 pcf mineral wool batt insulation for pipe greater than nom 4 in. diam, firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. 4. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. thickness of fill material applied within the annulus, flush with the top surface of floor or both surfaces of wall. At the point of contact location between pipe and concrete, a min 1/2 in. diam bead of fill material shall be applied at the concrete /pipe interface on the top surface of floor and on both surfaces of wall. W Rating applies only when CP601 S or CP604 sealant is used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S, CP604, CP606 or FS-ONE Sealant *Bearing the UL Classification Mark flill[2=E:u911® FIRESTOP SYSTEMS Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 14, 2004 System No. F Ratings — 1 & T Ratings — 1 & L Rating At Ambient — L Rating At 400 This is a typical detail for a penetration through a gypsum fire rated wall for multiple conduits up to 1" EMT. A W —L -1095 2 Hr (See Item 1) 2 Hr (See Item 3) Less Than 1 CFM /Sq Ft F — 4 CFM /Sq Ft SECTION A —A 1. Wall Assembly — The 1 or 2 hr fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide and spaced max 24 in. OC. B. Wallboard, Gypsum* — 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max size of opening 2 -5/8 in. by 18 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Electric Metallic Tubing (EMT) — One or more nom 1 in. diam steel electric tubing. The annular space shall be min 1/2 in. to a max 1 in. Conduit to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Material* — Sealant — For 2 hr F Rating, min 1 -1/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. For 1 hr F Rating, min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI, Inc. — FS —ONE Sealant *Bearing the UL Classification Marking FlRESTOP SYSTEMS Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Janumy 02, 1997 SSIF /ee C V.7 US This is a typical detail for a penetration through a gypsum fire rated wall for steel flexible cable up to 1'°. 0 System No. W—L--1214 F Rating — 1 Hr T Rating — 0 Hr 4 SECTION A —A 1. Wall Assembly The fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner specified if the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory and shall include the following construction features: A. Studs Wall framing shall consist of either wood studs or channel shaped steel studs. Wood studs to consist of 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide, fabricated from min 25 MSG galvanized steel, spaced max 24 in. OC. B. Wallboard, Gypsum* One layer of nom 5/8 in. gypsum wallboard, as specified in the individual Wall and Partition Design. Max diam of opening is 2 in. 2. Through Penetrants — Flexible Steel Conduit+ Nom 1 in. diam (or smaller) flexible steel conduit. Max one conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipe and periphery of opening shall be min 0 in. (point contact) to max 3/4 in. Conduit to be rigidly supported on both sides of floor or wall assembly. See Flexible Metal Conduit (DXUZ) category in the Electrical Construction Materials Directory for names of manufacturers. 3. All, Void or Cavity Material* — Sealant Min 5/8 in. thickness of fill material applied within annulus flush with both surfaces of wall. At point contact location between conduit and wall, a min 1/2 in. bead of fill material shall be applied at the conduit /wallboard interface on both side of wall. HILT! CONSTRUCTION CHEMICALS, DIV OF HILT! INC — FS —ONE Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking -J • FlRESTOP SYSTEMS Reproduced by HILT!, Inc. Courtesy of Underwriters Laboratories, Inc. October 19, 2000 �,ssiF,Fa C US Page: 1 of 1 This is a typical detail for a penetration through a gypsum fire rated wall for up 0 4" EMT. System No. W —L -1054 F Ratings — 1 and 2 Hr (See Items 1 and 3) T Rating — 0 Hr L Rating At Ambient — Less Than 1 CFM /Sq R L Rating At 400 F — 4 CFI /Sq Ft 1. Wall Assembly -- The 1 or 2 hr fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U3OO or U4O0 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide and spaced max 24 in. OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw — attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 in. higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* -- 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U3OO or U4O0 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32 -1/4 in. for steel stud walls. Max diam of opening is 14 -1/2 in. for wood stud walls. The F Rating of the firestop system is equal to the fire rating of the wall assembly. LrzJOL=O® F1RE91 f SYSl S Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. December 4, 2002 oositts Is Page: 1 of 2 System No. W —L -1054 F Ratings — 1 and 2 Hr (See Items 1 and 3) T Rating — 0 Hr L Rating At Ambient — Less Than 1 CFM /Sq Ft L Rating At400E- 4CFM /SgFt 2. Through — Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2 -1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -- Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant -- Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall . HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS —One Sealant *Bearing the UL Classification Mark C=01111]=1-u-'Ll'l Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. December 4, 2002 Page: 2 of 2 This is a typical detail for a penetration through a gypsum fire rated wall multiple cables with the *leave being optional. System No. W -L -3065 F Ratings —1 and 2 Hr (See Item 1) T Rating — O Hr SECTION A -A 1. Wall Assembly — The 1 or 2 fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2 -1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. elB. Gypsum Board* — Nom 5/8 in. (16 mm) thick gypsum board, with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300, U400 or V400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 5-1/2 in. (138 mm) when sleeve (Item 2) is employed. Max diam of opening is 4 in. (102 mm) when sleeve (Item 2) is not employed. The F Rating of the firestop system is equal to the fire rating of the wall assembly. 2. Metallic Sleeve — (Optional) - Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or Schedule 5 (or heavier) steel pipe or min 0.016 in. thick (0.41 mm, No. 28 ga) galv steel sleeve installed flush with wall surfaces. The annular space between steel sleeve and periphery of opening shall be min 0 in. (0 mm, point contact) to max 1 in. (25mm). When Schedule 5 steel pipe or EMT is used, sleeve may extend up to 18 in. (457 mm) beyond the wall surfaces. 3. Cables — Aggregate cross - sectional area of cable in opening to be max 45 percent of the cross - sectional area of the opening. The annular space between the cable bundle and the periphery of the opening to be min 0 in. (0 mm, point contact) to max 1 in. (25 mm) Cables to be rigidly supported on both sides of the wall assembly. Any combination of the following types and sizes of copper conductor cables may be used: A. Max 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and jacket. B. Max 25 pair No. 24 AWG telephone cable with PVC insulation and jacket. C. Type RG /U coaxial cable with polyethylene (PE) insulation and PVC jacket having a max outside diameter of %z in. (13 mm). D. Multiple fiber optical communication cable jacketed with PVC and having a max OD of 5/8 in. (16 mm). E. Through Penetrating Products * — Max three copper conductor No. 8 AWG . Metal -Clad Cable +. AFC CABLE SYSTEMS INC F. Max 3/C (with ground)(or smaller) No. 8 AWG copper conductor cable with PVC insulation and jacketing. G. Max 3/4 in. (19 mm) diam copper ground cable with or without a PVC jacket. H. Fire Resistive Cables* - Max 1 -1/4 in. (32 mm) diam single conductor or multi conductor Type MI cable. A min 1/8 in. (3 mm) separation shall be maintained between MI cables and any other types of cable. Through Penetrating Product* - Any cables, Metal -Clad Cable+ or Armored Cable+ currently Classified under the Through Penetrating Products category. See Through Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers. Hilti Firestop Systems Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. May 31, 2007 Page: 1 of 2 System No. W -L -3065 F Ratings —1 and 2 Hr (See Item 1) T Rating — 0 Hr 4. Fill, Void or Cavity Material * — Sealant or Putty — Fill material applied within the annulus, flush with each end of the steel sleeve or wall surface. Fill material installed symmetrically on both sides of the wall. A min 5/8 in. (16 mm) thickness of sealant is required for the 1 or 2 hr F Rating . An additional 1/2 in. (13 mm) diam bead of fill material shall be applied around the perimeter of sleeve on both sides of the wall when sleeve extends beyond surface of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601 S, CP606, FS -One Sealants or CP618 Putty *Bearing the UL Classification Mark +Bearing the UL Listing Mark Hilts Firestop Systems Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. May 31, 2007 CS SS I US ■ Page: 2 of 2 This is a typical detail for a penetration through a gypsum fire rated wall multiple cables with no sleeve. System No. W —L -3047 F Rating — 2 Hr T Rating — 3/4 Hr LA SECTION A —A 1. Wall Assembly -- The fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* -- Two layers of 5/8 in. thick gypsum wallboard, as specified in the individual Wall and Partition Design. Max diam of opening is 6 in. 2. Cables -- Max 7/C No. 12 AWG cables with polyvinyl chloride jacket and insulation. Aggregate cross — sectional area of tightly bundled cable group to be 33 percent of the aggregate cross — sectional area of the opening. Cables to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Material* -- Sealant -- Min 1 -1/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. Sealant to be forced into interstices of cable group to max extent possible. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS —One Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 09, 2003 Fire Sprinkler System No. C -AJ -1291 F Rating —2Hr T Rating —0Hr SECTION A -A 1. Floor or Wall Assembly — Min 2 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed ted of any UL Classified Concrete Blocks*. Max diam of opening is 30-7/8 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through- Penetrant — One metallic pipe or conduit to be installed either concentrically or eccentrically within the flrestop system. The annular space between pipe or conduit and periphery of opening shall be min 0 in. to max 7/8 in. Pipe or conduit to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used: A. Steel Pipe — Nom 30 in. diam (or smaller) Schedule 10 or heavier) steel pipe. B. Iron Pipe — Nom 30 in. diem (or smaller) cast or ductile iron pipe. C. Copper Pipe — Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. D. Copper Tubing — Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Conduit — Nom 6 in. diam (or smaller) steel conduit. F. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT). 3. Fill, Void or Cavity Material' — Sealant — Min 112 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point contact location between pipe and concrete, a min 1/4 in. diam bead of fill material shall be applied at the concrete /pipe interface on the top surface of floor and on both surfaces of wail. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS — ONE Sealant 'Bearing the UL Classification Mark FIRESTOP SYSTEMS Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. December 04, 2001 5 em No. W —L -2098 F Ra tags - 1 and 2 Hr (See Item 1 T Ratings — 1 and 2 Hr (see Item 1 L Rating At Ambient — Less Than 1 CFM Sq Ft L Rating At 400 F - 4 CFA! /Sq Ft SECTION A-A 1. Wall Assembly -- The fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* -- 5/8 in. thick, 4 ft wide with square or tappered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 4 -3/8 in. The hourly F and T Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrants -- One nonmetallic pipe installed within the firestop system. Pipe to be rigidly supported on both sides of floor or wall assembly. The space between pipe and periphery of opening shall be min 3/4 in. to max 1 -1/4 in. Pipe to be rigidly supported on both sides of the floor or wall assembly. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe -- Nom 2 in. diam (or smaller) Schedule 40 PVC pipe for use in closed (process or supply) piping system. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe -- Nom 2 in. diam (or smaller) SDR17 CPVC pipe for use in closed (process or supply) piping systems. 3. Fill, Void or Cavity Materials* -- Sealant -- Installed to completely fill the annular space between the pipes and gypsum wallboard on both sides of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS —One Sealant *Bearing the UL Classification Mark cart —J0� F1Ib j P s sT a1s Recrpr.ceC of ^�JerNri;e 13�.rrc nee 'rc. .cnucry 09. '003