RF-12-1618
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 177916 Permit Number: RF -8 -12 -1618 Scheduled Inspection Date: January 29, 2013 Inspector: Bruhn, Norman Owner: BALDWIN, CATHERINE Job Address: 126 NE 106 Street Miami Shores, FL 33138- Project <NONE> Contractor: AFFORDABLE CONTRACTORS INC /DBA LITOWIICH CONST Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number Parcel Number 1121360050060 Phone: (305)652 -0300 Building Department Comments RE -ROOF TILE COLOR THRU AND FLAT ROOF Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments January 28, 2013 For Inspections please call: (305)762 -4949 Page 3 of 22 A . Tomassi Roof Testing, Inc. 5451 NW 24th Street, Suite # 3 Margate, Florida 33063 TAS —106 Roof Tile Static Uplift Test Report Tel. 954 — 979 —1180 Fax. 954 — 979 —1182 Test Date: January 22, 2013 Project : 126 NE 106 Street, Miami Shores, Fl. Contractor: Affordable Contractors Inc Permit #: RF -8 -12 -1618 Roof Pitch: 3 : 12 Tile Installation Date: January 11, 2013 Attachment Method: Polyprofoam Tile Type: Movie Estate Spanish S All testing is in strict accordance with the 2010 Florida Building Code, High Velocity Hurricane Zone Testing Application Standard (TAS) 106 Each Test location was pulled using a Imada Force Gauge to a minimum of 35 lbs. TEST SUMMARY: Roof Area Total # of Tests # of Tests Passed % Passed Field 20 20 100% Corner 9 9 100% Perimeter 20 20 100% Hip (Approx 0 Total) NA NA NA Ridge (Approx 62 Total) 7 7 100% TEST RESULTS: PASSED See Attached Sketch For Further Details. Report Reviewed by: Dominick Scarfo, AR001 e 48 Dade County Certified Testing Agency # 12- 0710.03 Revises: # 07- 0720.04 Testing * Design Specifications * Management * Litigation * Quality Assurance 14' Flat 32' 6' -r 16' T 12' T r T -r T '7 T 1- 8' Fiat T T T T Y T -r -r 22' TAS -106 Test Locations All Dimensions are Approximate 18' 30' T= Tested Tile and Passed R = Ridge Cap Tile Tested and Passed H = Hip Cap Tile Tested and Passed F= Any Tested Tile That Failed Project: 126 NE 106th Street Miami Shores Village, Fl. KIMBALL ELECTRONIC I_TORY, INC 8081 W21 LANE F L. 33016 . DP Part it €: DFSH-440 `L 199171 : NIA NIA NIA Specifications: +f- .2 LEIS 110 ? ff :: A TOMASSI ROOF TESTING, INC. 5451 NW 24 —STREET MARGATE Fl. Cal Date: 07-Jan-13 Cal. Due Cate: 07- Apr -13 Cal. Interval: 3 MONTHS Received: IN TOLERANCE Calibration Result: PASS Environmental, Cond 74 DEG F / 50 % RH Performed : FLAROLD VONDO Procedure: SYN156 Cal Location: ON -SITE thatthe abov e-II ed to meets or exceeds all as stated in the referenced procedure at the points tested tunless adan:Isise ). t has it nda rds a referenced t ti ' , of t IST �l rinsie standard lis measurer Laboratory, Inc Qua* �i a Man ral. KE I s tau 4�ity llip� able areey�'���� hen eq�_gi 4:1f !�, - -beretattlereeccereendettintetvit has explred. F �r Menufacturis Ma #etif44 Description AK©TSI 1254 DEAD WEIGHT SYSTEM AKOTSQ2052-SSOMYKSGHT S'°YSTI i Serial Number 827 624 Last Cal. Gad. Due (fie''. 1 30-Sep-13 34- Sep-13 QUalibOOSUrange: • OLD 3AVIER � SOW 07- dad -13 2.26;0.9 PM BALCEIRO 07- Jan -13 2:26:22 PM Ts b reps ced, MOOS*, uniessfentOsIon fcr the nublicdon den agorovedibstract isobiai ned In writing frornM Labs., Inc. Kimball Electronic Labs, Inc. - 8081 W. 21st Labe - Hialeah, FL 33016 Tel 305-3224792 - Toll Free: 1 83 -1094 - Fax 305-362-3125 - Web: www.kelilabs.c;om E.a Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 ILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: /2.6 NE /0 5-Tit 12V1_7,4_ AUG 2 BYO FBC 20 Permit No. dpi 1 g -101K Master Permit No. � City: Miami Shores County: Folio/Parcel #: / 1 .21e3 m ®OS ® 0060 Is the Building Historically Designated: Yes Miami Dade Zip: 33 13 —2. ®3 7 NO X Flood Zone: N/04- OWNER: Name (Fee Simple Titleholder): CA r t4 i= fQ 1 nl z 1 A LD t )1 ro Phone #: 6 °S.J 71-4(-4 26 % Address: / fo /4 / /0 6 S.7 -01 E.E �— City: /4 // ®A-€S State: Fe- ode /4/9 Zip: - 33/3c?®xa037 Tenant/Lessee Name: /VA Phone #: Email: eopii CONTRACTOR: Company Name: A FFoite. pros L E Co iei ttroi' S1 c , Phone #: 6 kS t - 0 3 ®m Address: es 4)6 f -3 —it_i✓ �--/- -4402"/ City: /I/i A i ^ State: F4- o#../�A Zip: 33179 Qualifier Name: 'T 5-e /3 /t 4 . L i tom+ co i Gk Phone #: (3 DS) 3X-- al 03 State Certification or Registration #: C CC- /3a _5-7 63 Certificate of Competency #: L Contact Phone #: l 3 a r ) 6 3 2- - 3 (O 3 Email Address: J 1 P� IA t (� 6� IS o a i t-+- DESIGNER: Architect/Engineer: 14I Pt Phone #: se Value of Work for this Permit: $ �/ ` __ _ Square/Linear Footage of Work: / / o S T Type of Work: Addition ❑Alteration ❑New X2epair/Replace UDemolition Description of Work: A R©eF CP1 .T; AL- : ONe- sroe y /JAtS 0Ait -I) 7Tie 4. FLAT — rii.=Ct ( c : . 4 Fc_i rt 330 ST 9-r° s'PColor thru tile: ********+x*+x+x*: *** * ****** *****m+x*x:** ***x:*x:*m+xu:******** ********** *+x** ********* Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 161'N Bonding Company's Name (if applicable) Bonding Company's Address �O City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and MR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be poa ; d at job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absen -° of s post otice, the inspection will not be approved and a reinspection fee will be charged. Signature Cf674,- Owner or Agent Contractor The foregoing instrument was acknowledged before me this 10 The for oing i ment was ackn �1 day of 1, 20/i, by Lam' �//f f`;1day of / ,� , 20J., by who is personally known to me or who has produced 4'102 who is personally known to me or who has As identification a nikkhitli1itiake an oath. Ex° • �m „'�'� NOTARY PUBLIC: Sign: Print: My Commission Expires: • 1,7j 1 •• as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Exp + 1' !�' � �1� t�l'�l�tos /�. L 1 l�,f{,�'!..c of Florida . 3.1 t Notary - " °' Ex fires Sep 23.2015 r� �� „ omm. p 82 m`?�iti`�ae Commission �... o` ,:• Bonded Through National Notary Assn. ****** ** ********** *s+ *w+ s******* **x:******** ****** ***+ x*** *x: ******* ****a: *: x** **+ x**** ***x:+ x** *x: *****x:*********** *** APPROVED BY VI; ` r Cam- Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 11- 2136 - 005 -0060 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 111111111111 11111 11111 11111 1111111111 11111111 CFN 2012R0574290 o OR Bk 28229 Ps 2042i (1Ps) RECORDED 08/15/2012 11:25 :06 HARVEY RUVINe CLERK OF COURT MIAflI —DADE COUNTY, FLORIDA LAST PAGE 1. Legal description of property and street/address: SUBDIVISION: DUNNINGS MIAMI SHORES EXT NO 1; LOT: 6; BLOCK 201; PB 41 -51 126 NORTH EAST 106 STREET; MIAMI SHORES, FLORIDA 33138 -2037 2. Description of improvement: RE -ROOF 3. Owner(s) name and address: MS. CATHERINE BALDWIN 126 NORTH EAST 106 STREET; MIAMI SHORES, FLORIDA 33138 -2037 Interest in property: FEE SIMPLE Name and address of fee simple titleholder: SAME AS TITLEHOLDER 4. Contractor's name and address: AFFORDABLE CONTRACTORS, INC. 285 NE 185th STREET - SUITE # 24 MIAMI, FLORIDA 33179 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: NONE NONE NONE NONE 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and address: MS. CATHERINE BALDWIN 126 NORTH EAST 106 STREET; MIAMI SHORES, FLORIDA 33138 -2037 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713. 13(1)(b), Florida Statutes. Name and address: JOSEPH A. LITOWICH CIO AFFORDABLE CONTRACTORS, INC. 285 NE 185th STREET - SUITE # 24 MIAMI, FLORIDA 33179 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) SIX (6) MONTHS FROM DATE OF FILING Signature of Owner Print Owner's Name Sworn to and subscribed before Notary Public Print Notary's Name My commission expires: Prepared by: Joseph A. Litowich 285 N.E.185th Street Ste. 24 Miami, FL 33179 (305) 652-0300 STATE OF F: OR D \, COUNTY OF DADE O HEREBY CERTIFY That This i,, o iTUO c -'pyof M9 Oii n ! ii d idnThis ° CF on dny , -,,r Y,w�}'`�.12 A D 20 "Id an', i i u i:I. HARVEY � N CLERK, of Circuit and County Courts BY - 1/ i / 1L! D.C. Owne4s Notification Form HVHZ 2010 • "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofmg contractor to provide the owner with the required roofmg permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofmg system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. MI 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofmg system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofmg, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofmg work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofmg nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofmg system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's /Agent's Signature: ��, .; �� -. >`s e�" Date: Contractor's Signature: Property Address: 126 N. E. 106 STREET; MIAMI SHORES, FLA. Permit Number: Scc4ion A /13 "Delivering Excellence Every Day" Master Permit No: Contractor's Name: Job Address: Miami -Dade County HVHZ Electronic Roof Perini Form . BY: Section A (General Information) Process No: 1AFFORDABLE CONTRACTORS, INC. 1126 N. E. 106 STREET; MIAMI SHORES, FLORIDA Roof Category Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Other: ❑ Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes Roof Type Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance Ar here Gas Vent Stacks located on the roof? ❑ Yes 0 No If yes, what type? ❑ Natural ❑ LPGX Low slope roof area (ft.2) 350 SF Roof System Information Steep Sloped area (ft.2) 1600 SF Section B (Roof Plan) Total (ft.2) 1950 SF Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Corner Size (a' x a'): 3' x 3' 13 13 12 18 13 25 11 13 43 11 1 F 15 10 18 40 1 Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT a SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS 15 1 Tile Rot System 'Delivering Excellence Every Day" Roof System Manufacturer: Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System Boral Roofing, LLC. (Monier) Notice of Acceptance Number (NOA): Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): 12- 0308.21 P1: -45.0 P 2: P 3: Maximum Design Wind Pressures, (From the NOA Specific system): -°o � ! psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: Roof Mean Height: "/12" Method of Tile Attachment: ft. — Adhesive, Large Paddy Polyfoam Polypro - Alternate Method of Tile Attachment per NOA: Drip Edge Size & Gauge: Drip Edge Material Type: -3" face 24 ga.— — Galvinized Metal— Deck Type: —1" x 6" T & G— Optional Insulation: N/A Optional Nailable Substrate: Optional Nailable Substrate Attachment: N/A Basesheet Type: K30 ASTM TYPE II D -226 Fastener Type for Basesheet Attachment: 1 -1/4" R/S Galv Nails with 1 -5/8" Galv Tin Tab Tile Underlayment (Cap Sheet) Type: POLYGLASS TU PLUS Tile Underlayment Attachment Method: SELF- DHERED Drip Edge Fastener Type: I 1 -1/4" R/S Galy Nails @ 4 C/C Tile Profile: Hook Strip /Cleat gauge or weight: SPANISH S Section E "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P 3: -45.0 x xX x� 27.01 - Mg: - Mg: - Mg: = Mr1: = Mr2: = Mr3: Method 3 "Uplift Based Tile Calculations Per RAS 127" NOA Mf NOA Mf NOA Mf For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1: P2: P3: -45.0 -95.1 x 1: x 1: x 1: Description Design Pressure X w: x w: x w: 1.08 - W: - W: - W: x cos 0: x cos 0: x cos 0: C = Fr1: = Fr2: = Fr3: 31.58 Where to Obtain Information to complete tile calculations Symbol P1 or P2 or P3 Where to Find r 66.5 NOA F' NOA F' NOA F' Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Required Moment Resistance Mf Mr Product Approval (NOA) Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Average Tile Weight Tile Dimensions Fr W I = length w = width Calculated Product Approval (NOA) Product Approval (NOA) Section MIAMI -CASE COUNTY Miami -Dade County HVHZ Electronic Roof Permit Form Section C Page (Low Slope Roof Systems) "Delivering Excellence Every Day" Fill in the specific roof assembly components. If a component is not required, insert not applicable (n /a) in the text box. Top Ply: ROOF SYSTEM MANUFACTURER: Product Approval (NOA): 7 -u4Z 3.0 / i System Type: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (P1) Field: (P2) Perimeters: (P3) Comers: psf psf psf Maximum Design Pressure From NOA: Roof Slope: Parapet Walls: Deck Type: Support Spacing: Alternate Deck Type: Existing Roof. - 60.0 " : 12 Roof Mean Height: No 0 Yes Parapet wall Height: psf —1" x 6" T & G- " o/c ft. Fire Barrier: 1 N/A Vapor Barrier: 1 N/A Anchor Sheet: JM PermaPly 28 Anchor Sheet Fastener / Bonding Material: 1 -1/4" R/S GaIv Nails with 1 -5/8" Galv Tin Tabs Insulation Base Layer Size & Thickness: N/A Insulation Base Layer Fastener / Bonding Material: N/A Insulation Top Layer Size & Thickness: N/A Insulation Top Layer Fastener / Bonding Material: N/A Base Sheet(s) & No. of Ply(s): 1 Ply: Polyglass Elastobase Base Sheet Fastener / Bonding Material: Gaiv Nails with 1 -5/8" Galv Tin Tabs Ply Sheet(s) & No. of Ply(s): 1 Ply: Polyglass Elastoflex SA V 1 Ply Sheet Fastener / Bonding Material: Self- Adhered ft. Polyglass Elastoflex SA P Top Ply Fastening / Bonding Material: Self- Adhered • Surfacing: SINGLE PLY MEMBRANE: Factory- Applied Granules Single Ply Manufacturer / Type: N/A Single Ply Sheet Width: No. of Single Ply 1/2 sheets: Single Ply Membrane Fastening / Bonding Material: " 1/2 Sheet Width: N/A I N/A rA FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT 1. Field: L;aJ " o/c @ Laps & 2. Perimeter. " o/c @ Laps & 3. Comer: " o/c @ Laps & rows rows rows " o/c " o/c " o/c NUMBER OF FASTENERS PER INSULATION BOARD: 1. Field: 2. Perimeter Insulation Fastener Type N/A 3. Corner. WOOD NAILER TYPE AND SIZE: N/A Wood Nailer Fastener Type and Spacing: EDGE & COPING METAL SIZES: Edge Metal Material: Edge Size: Hook Strip Size: Edge Metal Attachment: 1 -1/4" R/S GaIv Nails @ 4" C/C Coping Matenal: — PARAPET COPING METAL N /A- Coping Size: — COPING METAL SIZE N /A- Hook Strip Size: - COPING METAL HOOK STRIP N /A— Parapet Coping Metal Attachment: N/A Edge Pe[ailable Deck MIAMIDADE COUNTY °Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Top Ply Miami -Dade County HVHZ Electronic Roof Permit Form Interplies Base Sheet ti ti1 Roof Deck A ' •s 4 Drip Metal Roof Mean Height: Drip Metal: 10 ft. 3" x 3" Galvanized (26 gage) Surfacing: Factory- Applied Granules Top Ply: IPolyglass Elastoflex SA P Interplies: Polyglass Elastoflex SA V Base Sheet: IJM PermaPly 28 & Polyglass Elsatobase Deck Type: 1 x 6 Tongue & Groove Wood PIA DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.aov /oera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tejas Espana Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 11- 0714.01 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing High Profile Roofing Tiles Concrete 1. SCOPE This approves a system using Tejas Espana Concrete Roof Tile, as manufactured Boral Roofing LLC in Katy, TX. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by - Applicant Tejas Espana Tile Trim Pieces Test Product Dimensions Specifications Description 1= 16'/2" TAS 112 High profile, interlocking, one -piece `S' shaped, w = 13" high pressure extruded concrete roof tile 1/2" thick equipped with two nail holes. For direct deck or 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Katy, TX. 2.2 EVIDENCE SUBMITTED Test Agency, Redland Technologies Redland Technologies Redland Technologies Redland Technologies Letter Dated Aug. 1, 1994 Redland Technologies P0631 -01 Test Identifier 7161 -03 Appendix III 7161 -03 Appendix II P0402 TAS 112 Nutting Engineering The Center for Applied Engineering, Inc. 13343.1 22- 7688 -3 25- 7688 -10 battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Test Name/Report Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail - On) Wind Tunnel Testing TAS 108 (Mortar Set) Physical Properties TAS 112 Static Uplift Testing TAS 101 (Adhesive Set) TAS 101 (Mortar Set) Date Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 July 1994 June 2006 June 1996 July 1996 NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 2 of 6 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier The Center for Applied 25- 7688 -5 Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 25- 7688 -4 520111 -3 520191 -2 -1 Calculations Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Test Name/Report Static Uplift Testing TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing TAS 102 (4" Headlap, Nails, Clips) Static Uplift Testing TAS 101 Aerodynamic Multiplier Two Patty Adhesive Set System 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 Date June 1996 June 1996 Dec. 1998 March 1999 March 1999 April 1999 March 1995 February 1996 April 1996 December 1996 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 3 of 6 4. INSTALLATION 4.1 Tejas Espana Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Tejas Espana 10.2 1.33 1.08 Table 3. Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile Table 2: Aerodynamic Multipliers - A. (ft3) 4 ":12" Tile 6 ":12" X (ft3) X (ft3) Battens Profile Battens Batten Application Direct Deck Application Tejas Espana Battens Direct Deck 0.262 0.284 Table 3. Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Tejas Espana Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.62 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Tejas Espana 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw. Shank Nails (Eave Clip) 38.1 38.1 41.8 NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 4 of 6 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Tejas Espana Adhesive' 29.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Profile Tile Application Minimum Attachment Resistance Tejas Espana 3M' M 2- Component Foam Roof Tile Adhesive AH -160 5 See specific mortar manufacturer's Notice of Acceptance 66.53 3M' M 2- Component Foam Roof Tile Adhesive AH -160 38.74 3 Large paddy placement of 63grams 4 Medium paddy placement of 24grams Table 7: Attachment Resistance Expressed as a Moment - Mf(ft -Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Tejas Espana Mortar Sets 24.5 5 See specific mortar manufacturer's Notice of Acceptance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". LABEL FOR TEJAS ESPANA CONCRETE TILE (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 5 of 6 PROFILE DRAWING When using only one mechanical fastener, use this hole. 16-1" TEJAS ESPANA CONCRETE ROOF TILE END OF THIS ACCEPTANCE 13" NOA No.: 12- 0308.21 Expiration Date: 09/14/16 Approval Date: 06/21/12 Page 6 of 6 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA # 11- 0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 1 of 8 •t ROOFING COMPONENT APPROVAL Category: Roofing Sub - Category: Underlayment Material: SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'33/8" Or 65'x 3' 60 mils thick Roll: 32' 10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. TAS 103 and A rubberized asphalt waterproofing membrane, ASTM D 1970 glass -fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 A rubberized asphalt self - adhering, glass- fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Haze1ton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency, Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier 11756.04.01 -1 11756.08.01 -1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 PRI01111 PUSA- 005 -02 -01 PUSA - 018 -02 -01 PUSA- 035 -02 -01 PUSA-033-02-01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA- 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103 /ASTM D4798 & G155 TAS 110 /ASTM D4798 & D1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: . Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-I/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. 1R-Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre- existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick 1R-Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 6 Roofing Tiles (6 Max. Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MANMADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 " /12" or greater. It is suggested that on pitch/slopes in excess of 6 % "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11- 1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 Page 8 of 8 MJAMI•LlADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.gov/building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® A.B160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMFDADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AN 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Polypro AH160 Foampro0 RTF1000 ProPack® 30 & 100 Dimensions Test specifications N/A TAS 101 N/A N/A Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability CIosed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 Ibs.ft.3 18 PS1 Parallel to rise 12 PS1 Perpendicular to rise 28 PS1 Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change ® -40° F., 2 weeks +6.0% Volume Change ®158 °F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMFDADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test NamelRenort Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. (F1) w F'= MS 2 MIAMFDADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH 160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro@ AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polyproo AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MI AMI DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Hall through plastic cement Underayment 1, 10 In. Paddy (Beneath Tile) Ease Coupe Eave course only: Keep adhesive approx. 4 In. up front wormholes Fascia WeepMie Ewe closure Ode edge 1) Place enough adhesive to achieve ft to 23 s eep plt2x4stor square I n c h e s In contact w i t h the pantile \ "leer pitch "pp0cations )Tm1 m�tde wn. face as "dl � hro 112In. Than Install the tire. Underlayment Nati through pleads cement MIAMIOADE COUNTY APPROVED Piton oft °save course cover We. Abut tosecond course of pantiles, Ensure ease end of pan end war Mee ere flash al ease line. Eavedwure Weephole Fascia (minter shown} Sheathing Optional PoM•up Moiler on longitudinal edges oldie NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Underlaymant 1 Paddy [Beneath Tile) Eave Course Fascia Weephola Ease closure Drip edge Nall through plastic cement Undorlayment Paddy (Beneath Tile) 7 in. Ease Course Fascia Eau Closure NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nell through plastic cement Paddy (between tile) Paddy (under tile) Single paddy 3 In under tile x 3 in. Single paddy on under- layment Single paddy /! / 7 . medium on top of Hie \ \� alas va paddy y save Fascia course only Nall through plastic cement Nall through plastic cement Underiayment Single paddy under tile Single paddy between tile 2In. x 7 in. medium slae paddy save course only in.x3in. r 4 in. Single paddy on under - layment Single paddy on top of tile Eave Course Fascia Weepbole Eave closure Drip edge Single paddy between tile Pelin.x 3 In. Single paddy on undedayment Single paddy on top of tile Eave Come Eave Closure 2 in. x 71n. medium FasciIke paddy eave course only a END OF THIS ACCEPTANCE MIAMI DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 MIAMI DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations Miami Dade County PERA C onstructiConton rSectibn1e documentation submitted has been reviewed and accepted b Y to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-D e County y P ridut to have this Section (In Miami Dade County) and /or the AHJ (in areas other than Miami County) product or material tested for quality assurance purposes. this and the AHJ may immediately revoke,tmodify,por accepted product or materil fails to perform in manner, the manufacturer will incur the expense of s uch testing suspend the use of such product or material de County Product Control Section that thhs product or material fails to acceptance, if it is determined by Miami-Dade ty meet the requirements of the applicable building code. This product is approved as described herein, o and the has been desigd e t ocomply with the Florida Building Code including the High Velocity Hurricane Zone DESCRIPTION: Polyglass Self - Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's acrwise amed log city, state and following statement: "Miami -Dade County Product Control Approved", RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration NOA as an endorsement of any product. materials, use, and /or manufacture of the product or process. Misuse of this for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by ur e If any portion of the NOA is displayed, then it shall the be expiration date may be displayed in advertising liter y done in its entirety. INSPECTION: A copy of this entire NOA shall be provided fo the u user by the al ufacturer or its distributors and shall be available for inspection at the job site at the request d This revises NOA# 08- 0226.06 and consists of pages 1 through 28. The submitted documentation was reviewed by Alex Tigera. MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -259° WWW miamidade.a cry/ pera MIAMI -DADE COUNTY APPROVED NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 1 of 28 ROOFING ASSEMBLY APPROVAL Roofing Modified Bitumen SBS /APP /TPO Wood -112.5 psf Category:, Sub -Cate orY Materials Deck Tyne: Maximum Design Pressure TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE Test Product Dimensions S ecification Desch n 3 -3/8" ASTM D 6163, SBS modified asphalt coated fiberglass Type I reinforced base sheet. ASTM D 6164, SBS modified asphalt coated polyester Type I reinforced base sheet. ASTM D 6163, Self- adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a smooth top surface. ASTM D 6163, Self - adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a smooth top surface. ASTM D 6163, Self - adhered, fiberglass reinforced, SBS Type I modified back face nd membrane smooth top surface. ASTM D 6163, Self - adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a smooth top surface. ASTM D 6164, Self - adhered, polyester reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a granule top surface. ASTM D 6164, Self- adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a granule top surface. ASTM D 6222, Self - adhered, polyester reinforced, APP Type I adhering back face d membrane granule top surface. ASTM D 6222, Self - adhered, polyester reinforced, APP Type I modified bitumen membrane ui with a seurface. adhering back face and a granule p ASTM D 6164, Self - adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with to seurface. adhering back face and a granule p Product Elastobase Elastobase P 65' 2 "x3' 5' 2" x 3' 3 -3/8" Elastoflex SA V 32' 6" x 3' 3 -3/8" FR (1.5 -mm) Elastoflex SA V 32' 6" x 3' 3 -3/8" PLUS FR Elastoflex SA V 32' 6" x 3' 3-3/8" (1.5 -mm) Elastoflex SA V 32' 6" x 3' 33 /8" PLUS Elastoflex SA P 32' 6" x 3' 3 -3/8" FR Elastoflex SA P 32' 6" x 3' 3 -3/8" Polyflex SA P 32' 6" x 3' 33/8" Polyflex SA P FR 32' 6" x 3' 3-3/8" Polyfresko SBS SAP 32' 6" x 3' 33/8" MIAMI•DADE COUNTY APPROVED NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 2 of 28 Polyfresko SBS SAP FR Polyfresko APP SAP Polyfresko APP SAP FR PolyKool PG325 Cold Process Adhesive PG100 Asphalt Primer 32' 6" x 3' 3-3/8" 32' 6" x 3' 33/8" 32'6 "x3'33 /s" PG350 Mod Bit Adhesive PG400 Plastic Roof Cement PG425 Wet/Dry Roof Cement PG450 Flashing Cement PG500 MB Flashing Cement Polyplus 35 Premium Mod Bit Adhesive Polyplus 45 Premium Flashing Cement Polyplus 50 Premium MB Flashing Cement Polyplus 55 Premium Modified Flashing Cement ASTM D 6164, Self- adhered, fiberglass reinforced, SBS Type I modified bitumen membrane with a self - adhering back face and a granule top surface. ASTM D 6222, Self - adhered, polyester reinforced, APP Type I modified bitumen membrane with a self - adhering back face and a granule top surface. ASTM D 6222, Self- adhered, polyester reinforced, APP Type I modified bitumen membrane with a self - adhering back face and a granule top surface Self - adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a white film laminate on the top surface. ASTM D3019 A fibered cold process adhesive for use with Type III roll or BUR roofing. ASTM D41 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. ASTM D3019 A fibered rubberized adhesive designed for use Type III with modified bitumen membranes. ASTM D4586 A thick, fibered, rubberized flashing cement for ASTM D3409 use in dry or damp conditions. ASTM D4586 A thick, fibered, rubberized flashing cement for ASTM D3409 use in dry or damp conditions. ASTM D4586 A thick, fibered, rubberized flashing cement. A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. A fibered rubberized adhesive designed for use with modified bitumen membranes. 32' 10" x 3' 3-3/8" ASTM D6222 Type 1 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube ASTM D4586 ASTM D3019 Type II1 1, 3, 5, 50, 55 gal. ASTM D4586 A thick, fibered, rubberized flashing cement. or tube 1, 3, 5, 50, 55 gal. ASTM D4586 or tube 1, 3, 5, 50, 55 gal. ASTM D4586 or tube A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. A mastic compound for use as a roof flashing adhesive. NOA No.: 11- 0425,07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 3 of 28 APPROVED INSULATIONS: Product Name Polytherm -H Polytherm Polytherm Composite ACFoam II ACFoam III High Density Wood Fiberboard Perlite Insulation Type X Gypsum DensDeck, DensDeck Prime H- Shield H- Shield CG ENRGY -3, JM ISO 3 Fesco Board Multi -Max FA -3 SECUROCK Gypsum -Fiber Roof Board MIAMI•DADE COUNTY APPROVED TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate/Perlite composite insulation. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Fire resistant rated gypsum. Gypsum insulation board Polyisocyanurate foam insulation Polyisocyanurate /perlite composite insulation Polyisocyanurate foam insulation Expanded mineral fiber Polyisocyanurate foam insulation Fiber reinforced coverboard Manufacturer (With Current NOA) Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Atlas Energy Products Atlas Energy Products Generic Generic Generic Georgia - Pacific Hunter Panels, LLC Hunter Panels, LLC Johns Manville Corp. Johns Manville Corp. RMax, Inc. USG NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 4 of 28 APPROVED FASTENERS: Fastener Number Product Name 1. Dekfast Fasteners #12, #14 & #15 2. Dekfast Hex Plate 3, Dekfast Dekflat Round Plastic Lock Plate 4. #12 & #14 Roofgrip 5. Flat Bottom Metal Plate 6. Plastic Plate 7. Tru -Fast HD ( #14) TABLE 3 Product Description Insulation fastener for wood, steel and concrete decks Galvalume hex stress plate. 8. Tru -Fast 3" Metal Insulation Plate 9. Tru -Fast TP 10. Polygrip Fasteners #12, #14 & #15 11. Polygrip Hex Plates 12. Dekfast Galvalume Steel steel plate 13. AZ50 3 in. Round 13. Millenium One- StepT"' Insulation Adhesive Foamable Adhesive Polypropylene locking plate. Dimensions Insulation and membrane fastener A2 -SS aluminized steel plate Polyethylene stress plate Insulation fastener for steel and wood decks Round Galvalume AZ50 steel plate Carbon steel fastener Insulation fastener for wood, steel and concrete decks Galvalume hex stress plate. 2 7w' x 3 'A" 3" x 3 '/4" Various 3" square 3.2" round 3.23 round 3" round Various Various 2 7!8" X 3 'A" 3" round Various Manufacturer With Current NOA SFS Intec SFS Intec SFS Intec OMG OMG OMG The Tru -Fast Corp. The Tru -Fast Corp. The Tru -Fast Corp. Polyglass USA, Inc Polyglass USA, Inc SFS Intec Adco Products NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 5 of 28 APPROVED SURFACING: Prod et, Name PG200 Non - Fibered Roof Coating PG300 Fibered Roof Coating TABLE 4 Pr oduct Description A non fibered asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR PG600 Non - Fibered Non - fibered aluminum roof Aluminum Roof Coating coating. PG650 Fibered Aluminum Fibered aluminum roof coating. Roof Coating PG700 White Elastomeric Roof Coating PG800 Non - Fibered Asphalt Emulsion Roof Coating PG850 Fibered Asphalt Emulsion Roof Coating Polyplus 65 Premium Fibered Aluminum Roof Coating Polyplus 60 Premium Non - fibered aluminum roof Non - Fibered Aluminum coating. Roof Coating Polybrite 70 White Elastomeric Roof Coating Application Rate I' /z -2 gal /sq 11/2-2 gal /sq A premium white eastomeric acrylic based roof coating (water - based). A polyester fabric may be used for reinforcement with this coating. An asphalt base, un- fibered clay emulsion An asphalt base, fibered clay emulsion Fibered aluminum roof coating. Mule -Hide 111 Non - Fibrated Roof Coating Mule -Hide 102 Fibrated Roof Coating 1/2-1 gal /sq 11/2-2 gal /sq 1 -11/4 gal /sq Specification TAS 140 Manufactu rer Polyglass USA, Inc. ASTM D4479 Polyglass USA, Inc. ASTM D2824 Polyglass Type I USA, Inc. ASTM D2824 Polyglass Type II1 USA, Inc. ASTM D6083 Polyglass USA, Inc. 3 gal /sq in ASTM D1227 USA, Polyglass two coats A premium white eastomeric acrylic based roof coating (water - based). A polyester fabric may be used for reinforcement with this coating. A non - fibrated asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR 3 gal /sq in two coats 11/2-2 gal /sq ASTM D1227 Polyglass USA, Inc. ASTM D2824 Polyglass Type III USA, Inc. 1/2-1 gal /sq ASTM D2824 Polyglass Type I USA, Inc. 1 -11/2 gal /sq ASTM D6083 Polyglass USA, Inc. 11/2-2 gal /sq 1' /z -2 gal /sq TAS 140 Mule -Hide Products Co.. Inc. ASTM D4479 Mule -Hide Products Co., Inc. NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 6 of 28 APPROVED SURFACING: TABLE 4 Product Product Name Description Mule -Hide 416 Standard Non- fibrated aluminum roof Non - Fibrated Aluminum coating. Roof Coating Mule -Hide 406 Standard Fibrated Aluminum Roof Coating Mule -Hide 401 Premium Fibrated Aluminum Roof Coating Mule -Hide 410 Premium Non - Fibrated Aluminum Roof Coating Mule -Hide 311 Emulsion Non - Fibrated Mule -Hide 301 Emulsion Fibrated Gravel Slag Fibrated aluminum roof coating. Fibrated aluminum roof coating. Non - flbrated aluminum roof coating. An asphalt base, un- fibered clay emulsion Application Rate '/2 -1 gal /sq 11/2-2 gal /sq 11/2-2 gal /sq 1/2-1 gal /sq 3 gal /sq in two coats An asphalt base, fibered clay 3 gal /sq in emulsion two coats To be installed in a flood coat of 400 lbs /sq approved asphalt at 60 lbs /sq To be installed in a flood coat of 300 lbs /sq approved asphalt at 60 lbs /sq Manufactu Specification rer ASTM D2824 Mule -Hide Type 1 Products Co., Inc. ASTM D2824 Mule -Hide Type III Products Co., Inc. ASTM D2824 Mule -Hide Type 111 Products Co., Inc. ASTM D2824 Mule -Hide Type I Products Co., Inc. ASTM D1227 Mule -Hide Products Co., Inc. ASTM D1227 Mule -Hide Products Co., Inc. N/A Generic N/A Generic NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 7 of 28 EVIDENCE SUBMITTED: Test Aaencv, Factory Mutual Research Corporation Underwriters Laboratory Trinity I ERD PRI Asphalt Technologies Test Nanne/Renort 4470 4470 4470 TAS 114 TAS 114 TAS 114 TAS 114 TAS 117(B) -ASTM D903 TAS 114 TAS 114 TAS 114 -J TAS 114 -J TAS 117(B) -ASTM D6862 ASTM D6164 / ASTM D6222 ASTM D6164 / ASTM D6222 ASTM D6222 TAS 114(D) — ASTM D1876 ASTM D6222 FM 4470 & TAS 114 ASTM D6163 / ASTM D 4601 ASTM D6222 ASTM D6222 ASTM D6163 Report No. J.I. 3001334 J.I. 3000857 J.I. 3004091 00NK20869 11751.05.03 11758.08.03 PI 738.02.07 020841.06.04 11757.12.00 -1 11757.04.01 -1 P9260.03.08 P7860SC.11.08 C8500SC.11.07 P10490.08.08 P10490.10.08-R1 P7400.03.08 -R2 P10070.10.08 P10490.10.08 -2 P33970.03.11 P33960.03.11 PUSA -061 -02 -02 PUSA- 062 -02 -02 PUSA - 064 -02 -02 Date 02.15.00 01.12.00 01.12.00 06.08.00 05.30.03 08.1 1.03 02.05.07 06.02.04 12.01.00 04.27.01 03.21.08 11.30.07 11.30.07 08.13.08 10.03.08 10/09/08 10 /09/08 10/30/08 03/15/11 03 /15 /11 01.28.08 12.04.08 02.27.08 NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 8 of 28 Membrane Type: Deck Type 1: Deck Description: System Type E(3): SBS /APP Wood, Non - Insulated 19/3211 or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood screws at 6" o.c. Base sheet is mechanically attached to roof deck. All General and System Limitations apply. One ply ot;,,F.,tobme.or Elastobase P fastened to the deck as described below: Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet. One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self - adhered. One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. ® Base Sheet: Fastening: p Ply Sheet: ® Membrane: Surfacing: Maximum Design Pressure: -60 psf; (See General limitation #7.) MIAMI-DADE COUNTY APPROVED NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 24 of 28 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply.6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base rsheet p shall be applied using spot mopping with approved asphalt, 12" diameter circles, 4 o.c.; mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. value of 5. Fastener spacing for insulation attachment is based n Standard TAS 105 Stlf t e fastener value, 275 lbf., as tested in compliance with Testing App tcatio as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor /base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation arinal analysis, es be nor elxtrap shall be permitted for olation e roof pressure zones field, perimeters, and corners). Neither enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE MIAMI -DADE COUNTY APPROVED NOA No.: 11- 0425.07 Expiration Date: 10/11/12 Approval Date: 12/22/11 Page 28 of 28 ,TGFU.R14571 - Roofing Systems Page 1 of 9 ONLINE CERTIFICATiOiNS DIRECTORY Paae Bottom See General Information for Rooflna Systems POLYGLASS USA INC 1111 W NEWPORT CENTER DR DEERFIELD BEACH, FL 33442 USA TGFU.R14571 Roofing Systems Roofing Systems SINGLE PLY MEMBRANE SYSTEMS R14571 Unless otherwise indicated, the insulation and base sheet are mechanically fastened in place; the membrane is heat welded in place. (Optional) Noncombustible deck classifications are applicable for use over combustible (15/32 In. min plywood) decks when 1/2 in. (min) gypsum board or 1/4 in. (min) G -P Gypsum "DensDeck ® Roofboard", "DensDeck Prime@ Roofboard", "DensDeck DuraGuard"" Roofboard" or 1/4 in. (min) USG Corp SECUROCKTM Roof Board Type FRX -G are used directly over the combustible deck with all joints staggered 6 in. (min) from plywood joints. Unless otherwise indicated, in any noncombustible roof deck Classification any UL Classified insulation may be utilized underneath a layer of 1/4 in. (min) G -P Gypsum "DensDeck ® Roofboard", "DensDeck Prime@ Roofboard", "DensDeck DuraGuard"" Roofboard" or 1/4 in. (min) USG Corp SECUROCKTM Roof Board Type FRX -G. General statement for use of vapor retarders and /or deck/insulation adhesives (NC decks only): When such vapor retarders or deck/insulation adhesives are acceptable to POLYGLASS they may be utilized. " POLYGLASS BASE ", "MODIBASE ", "Polyglass G2 Base" may be used in lieu of any Type G2 base sheet in any NC Classification. These products may also be used In any C -15/32 Classification in which a generic Type G2 Is referenced (i.e. not brand specific). "POLYGLASS Ply 4 ", " POLYGLASS Ply 6" (Type Gl) and "POLYGLASS VENTED BASE" may be used in any NC Classification. These products may also be used in any C -15/32 Classification in which a generic Type G1 is referenced (i.e. not brand specific). "BASE PRO" may be used as an acceptable alternate of "ELASTOFLEX SA V" base sheet. References to polyisocyanurate Insulation may include Polyglass Products "POLYTHERM ®" and "POLYTHERM® Tapered ". Acceptable alternates to the membranes listed are given below: Membrane Listed Acceptable Alternatives "POLYBOND" "MODIBOND" or "Torch Pro Smooth" "POLYBOND G" "MODIBOND G" or "Torch Pro Granular" "Polytherm ", " Polytherm Tapered" or "Polytherm Composite" insulations may be used wherever polyisocyanurate insulations are specified in the Classifications below. Insulation may be optional for any non - combustible deck roofing system unless the insulation acts as a coverboard over another insulation. Class A - Ballasted Incline: 3 1. Deck: C -15/32 Insulation: — Polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic or perlite, any thickness. Ply or Base Sheet: — One ply "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or " ELASTOSHIELD TS G ". Membrane: — One or more layers "DUFLEX ", "DUFLEX G ", " POLYGLASS 350 CAP ", "POLYFRESKO 350 CAP ", "POLYBOND ", " POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "POLYFRESKO TORCH ", "Xtraflex APP G" or "POLYFLEX G" (modified bitumen), heat welded, or one or more layers " ELASTOFLEX V ", " ELASTOFLEX V -C ", "ELASTOBASE ", " ELASTOFLEX S6 ", " ELASTOFLEX P -C" or "ELASTOSHIELD TS G ", mopped in hot asphalt or heat fused. Surfacing: — Gravel, embedded in hot mopping asphalt. http: / /database.ul. corn/cgi- binIXYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 7/30/2012 • ,TGFU.R14571 - Roofing Systems Page 2 of 9 Class B - Ballasted 1. Deck: C -15/32 Incline: 3 Base Sheet: — Type G2. Membrane: — "DUFLEX ", "DUFLEX G ", "POLYBOND ", " POLYGLASS 350 CAP ", "POLYFRESKO 350 CAP ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "POLYFRESKO TORCH ", " POLYFLEX G" or "Xtraflex APP G" (modified bitumen), heat welded, or one or more layers "ELASTOFLEX V ", " ELASTOFLEX V -C ", "ELASTOBASE ", " ELASTOFLEX S6 ", " ELASTOFLEX P -C" or "ELASTOSHIELD TS G ", mopped in hot asphalt. Surfacing: — Gravel, embedded in hot mopping asphalt or heat fused. Class A - Fully Adhered 1. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic or perlite, any thickness. Base Sheet: — One or more layers "ELASTOBASE ", "POLYFLEX ", "Xtraflex APP S ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "POLYFRESKO TORCH ", "Xtraflex APP G" or "POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Kokem Products "Sunguard Acrylic Roof Coating" at 1 gal /sq; or Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating or Karnak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4 -1 gal. /sq. . 2. Deck: C -15/32 Incline: 1/2 Insulation: — Two or more layers (insulation joints staggered a min of 6 In. from plywood deck joints) polyisocyanurate, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic or perlite, any thickness. Base Sheet: — One or more layers "ELASTOBASE ", "POLYFLEX ", "Xtraflex APP S ", " ELASTOFLEX V" , " ELASTOFLEX V -C" or Type G2 base sheet. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "POLYFRESKO TORCH ", "Xtraflex APP G" or " POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Kokem Products "Sunguard Acrylic Roof Coating" at 1 gal /sq; or Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating or Karnak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq.. 3. Deck: C -15/32 Incline: 1/2 Insulation: — 1/4 in. thick G -P Gypsum DensDeck®, perlite, wood fiber or glass fiber, 1 In., mechanically fastened. Base or Ply Sheet: — One or more layers "POLYFLEX" or "Xtraflex APP S" (mechanically fastened or heat welded), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (mechanically fastened or hot mopped). Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP 5 ", "POLYFRESKO TORCH ", "Xtraflex APP G" or "POLYFLEX G" (modifled bitumen), heat welded or hot mopped. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq; or Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating or Karnak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4 -1 gal. /sq.. 4. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness. Base Sheet: — " POLYFLEX" or "Xtraflex APP S" (mechanically fastened or heat welded) or Type G2, mechanically fastened or hot mopped. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "POLYFRESKO TORCH ", "Xtraflex APP G" or "POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Grundy Industries "al MB Aluminum Roof Coating" at 1 -2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4 -1 gal. /sq.. 5. Deck: NC incline: 1 Insulation (Optional): — Polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic, perlite or wood fiberboard, any thickness. Base Sheet: — One or more layers "DUFLEX" or " POLYFLEX" or "Xtraflex APP 5" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped, heat fused or mechanically fastened). Membrane: — "DUFLEX G FR ", "POLYFRESKO TORCH FR ", "Xtraflex APP G FR" or " POLYFLEX G FR" (modifled bitumen), heat fused. 6. Deck: C -15/32 Incline: 1/2 Base Sheet: — One or more layers "DUFLEX" or "POLYFLEX" or "Xtraflex APP S" or "POLYGLASS Base" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped, heat fused or mechanically fastened). http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 7/30/2012 •TGFU.R14571 - Roofing Systems Page 3 of 9 Ply Sheet: — One or more layers "DUFLEX" or " POLYFLEX" or "Xtraflex APP S" or "POLYGLASS Base" (heat fused) or " POLYGLASS Base ", "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped) or mechanically attached. Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR ", "Xtraflex APP G FR" or " POLYFLEX G FR" (modified bitumen), heat fused. 7. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), perlite (3/4 in. min), glass fiber (7/16 in. min), perlite/polyisocyanurate composite, perlite /urethane composite (2 In. min) or (2 in. min) polyisocyanurate covered with 1/2 in. perlite or wood fiberboard. Base Sheet: — One or more layers "DUFLEX" or " POLYFLEX" or "Xtraflex APP S" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" (heat fused, mechanically fastened or hot mopped) or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet: — One or more layers "DUFLEX" or "POLYFLEX" or "Xtraflex APP S" (heat fused) "ELASTOBASE ", " ELASTOFLEX V ", "ELASTOFLEX V -C" or Type G2 base sheet (hot mopped) or mechanically fastened. Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR ", "Xtraflex APP G FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 8. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, urethane, periite /polyisocyanurate composite, perlite /urethane composite, glass fiber or wood fiberboard, phenolic or perlite, any thickness. Base Sheet: — One or more layers "DUFLEX" or "POLYFLEX" or "Xtraflex APP S" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" (hot mopped, mechanically fastened or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — " ELASTOFLEX VG FR ", " ELASTOSHIELD TS G FR ", " ELASTOFLEX S6 G FR" or "POLYFRESKO MOP FR" (modified bitumen), hot mopped or heat fused. 9. Deck: C -15/32 Incline: 1/2 Base Sheet: — One or more layers "DUFLEX" or "POLYFLEX" or "Xtraflex APP S" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet: — One or more layers "DUFLEX" or "POLYFLEX" or "Xtraflex APP S" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", "ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically attached). Membrane: — " ELASTOFLEX VG FR ", " ELASTOFLEX S6 G FR', "POLYFRESKO MOP FR" or " ELASTOSHIELD TS G FR" (modified bitumen), hot mopped or heat fused. 10. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 In. min), perlite (3/4 in. min), glass fiber (15/16 In. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers "DUFLEX" or " POLYFLEX" or "Xtraflex APP S" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet: — One or more layers "DUFLEX" or " POLYFLEX' or "Xtraflex APP S" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically attached). Membrane: — " ELASTOFLEX VG FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or "ELASTOSHIELD TS G FR" (modified bitumen), hot mopped or heat fused. 11. Deck: NC Incline: 1 Insulation (Optional): — Cellular concrete, gypsum concrete, vermiculite concrete, perlite concrete or structural concrete. Primer: — Not UL Classified — as required by manufacturer. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", " POLYFLEX G ", "Xtraflex APP G ", " POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR ", "POLYFLEX ", "Xtraflex APP S ", " POLYFLEX G ", "DUFLEX G FR ", "Xtraflex APP G FR" or "POLYFLEX G FR ". Surfacing: — (not required for "POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR" or "DUFLEX G FR ") "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Monsey Products "Endure Aluminum Roof Coating ", at 1.5 gal /sq; or Grundy Industries "al MB Aluminum Roof Coating ", at 1 -2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq. 12. Deck: NC Incline: 1 Insulation (Optional): — Any thickness, one or more layers UL Classified perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate /composite, EPS /wood fiber, EPS /perlite or EPS /composite. Base Sheet: — One or more layers Type G1 or G2. Membrane: — One or more layers "POLYBOND ", "POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "Xtraflex APP G" or " POLYFLEX G" (modified bitumen), heat fused. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Fields "F350 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating ", 1 -1/2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PoiyPlus 60 ", applied at 3/4-1 gal. /sq. 13. Deck: NC Incline: 1/2 Barrier Board (Optional): — 1/2 In. gypsum board. Insulation (Optional): — Polyisocyanurate, any thickness. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 7/30/2012 ti .TGFU.R14571 - Roofmg Systems Page 4 of 9 Base Sheet (Optional): — Type G2, "DUFLEX ", "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C ", "Xtraflex APP S" or "POLYFLEX ". Membrane: — " ELASTOFLEX VG FR ", " POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR" (heat fused), " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" (hot mopped) or "ELASTOSHIELD TS G FR" (heat fused or hot mopped). 14. Deck: C -15/32 Incline: 1 Insulation: — 1/4 in. thick G -P Gypsum DensDeck ®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Ply Sheet: — Type G2, mechanically fastened. Membrane: — "POLYBOND ", " POLYFLEX" or "Xtraflex APP S" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq. 15. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, perlite, glass flber or wood fiberboard, any thickness. Base Sheet: — On ply Type G2, hot mopped or mechanically fastened or "ELASTOBASE ", heat fused, hot mopped or mechanically fastened. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or "ELASTOSHIELD TS G FR" hot mopped or heat fused. 16. Deck: C -15/32 Incline: 1/2 Base Sheet: — One ply Type G2 or "ELASTOBASE ", mechanically fastened. PIy Sheet: — One ply Type G2 (hot mopped or mechanically fastened) or "ELASTOBASE" (hot mopped, heat fused or mechanically fastened). Insulation (Optional): — Polyisocyanurate, perlite, glass fiber, any thickness. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or, ELASTOSHIELD TS G FR " hot mopped or heat fused. 17. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 In. min), glass fiber (15/16 in. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers "DUFLEX ", "Xtraflex APP S" or "POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). PIy Sheet (Optional): — One or more layers "DUFLEX ", "Xtraflex APP S" or "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", "ELASTOFLEX V -C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR ", "Xtraflex APP G FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 18. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers "DUFLEX ", "Xtraflex APP S" or "POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet (Optional): — One or more layers "DUFLEX ", "Xtraflex APP S" or "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", "ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or "POLYFRESKO MOP" (modified bitumen), hot mopped. 19. Deck: C -15/32 Incline: 1 Insulation: — 1/4 in. thick G -P Gypsum DensDeck ®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Ply Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX" or "Xtraflex APP S" heat welded. Surfacing: — Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at V4 -1 gal. /sq.. 20. Deck: C -15/32 incline: 2 -1/2 Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck® with all joints staggered 6 in. from the plywood joints. Base Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX G FR ", "Xtraflex APP G FR" or " POLYFRESKO TORCH FR ", heat fused in place. 21. Deck: C -15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — " ELASTOBASE" (poly /sand), mechanically fastened or "ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT' (self adhered). PIy Sheet (Optional): — " ELASTOBASE" (poly /sand), heat fused or mechanically fastened, or "ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT ", (self adhered). http: / /database.ul. com/cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 7/30/2012 t ' . TGFU.R14571 - Roofing Systems Page 5 of 9 Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or " POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", " ELASTOFLEX VG FR" or "ELASTOSHIELD TS G FR ", heat fused. 22. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate 1.5 in. (min.) with all joints staggered 6 -in. (min.) from the plywood joints. Base Sheet: j- Type G2, mechanically fastened followed by "ELASTOBASE ", mechanically fastened. PIy Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" , " ELASTOFLEX SA V FR "for "ELASTOFLEX SA V FR BASE VENT ", (self adhered) Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP S FR , ELA TOFLEX SA P FR") "POLYFRESKO SBS SA P FR ", or "DUFLEX G FR ", "POLYFLEX G FR ", "Xtraflex APP G FR ", " ELASTOFLEX S6 G FR ", "P LYFRESKO MOP FR ", " ELASTOFLEX VG FR" or " ELASTOSHIELD TS G FR ", heat fused. 23. Deck: NC Incline: 2 Insulation (Optional): — Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H- Shield ", any thickness. Base Sheet: — " ELASTOBASE" (poly /sand), heat fused or mechanically fastened or "ELASTOFLEX SA V FR ", " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT ", (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or " POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", "POLYFRESKO MOP FR ", " ELASTOFLEX VG FR" or " ELASTOSHIELD TS G FR ", heat fused. 24. Deck: C -15/32 Incline: 3 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — " ELASTOBASE" (poly /sand), mechanically fastened. PIy Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" , " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT ", (self adhered). Membrane: — " ELASTOFLEX S6 G FR" or "POLYFRESKO MOP FR ", heat fused. 25. Deck: NC Incline: 3 Insulation (Optional) : — Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H- Shield ", any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT" (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR" or "POLYFRESKO SBS SA P FR" (self adhered). 26. Deck: NC Incline: 1/2 Base Sheet: — Type G1 or G2, mechanically fastened. Membrane: — " POLYFLEX G ", "Xtraflex APP G" or "POLYBOND G ", heat fused. 27. Deck: NC Incline: 3 Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " POLYFRESKO SBS SA P FR "or "ELASTOFLEX SA P FR" (self adhered). 28. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V ", " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA" or " ELASTOFLEX SA V BASE VENT ", self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Membrane: — " POLYFLEX SA P ", "Xtraflex APP G SA" or "POLYFRESKO APP SA P" self - adhered or " POLYFLEX FG FR ", heat fused. 29. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min). Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened, with 6 in. offset to plywood joints. Base Sheet: — " ELASTOFLEX 56 ", " ELASTOFLEX P -C" (heat fused or mechanically fastened). Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or " POLYFRESKO MOP ", (heat fused). 30. Deck: NC Incline: 1/2 Insulation (Optional) — Atlas Roofing "ACFoam III" or "ACFoam II ", any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT ", (self adhered). Membrane: — "POLYKOOL SA" or "XtraKool APP S SA ", (self adhered). 31. Deck: 5/32 Incline: 1/2 http : / /-database.ul.com/cgi- bin/XYV /template /LISEXT /1 FRAME /showpage.html ?name =T... 7/3012012 k ,TGFU.R14571 - Roofing Systems Page 6 of 9 Base Sheet: — G2 Base sheet mechanically fastened followed by "ELASTOFLEX SA V PLUS FR" , " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — "POLYKOOL SA" or "XtraKool APP S SA ", (self adhered). 32. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA ", " ELASTOFLEX SA V" or "ELASTOFLEX SA V BASE VENT ", self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or "POLYFRESKO MOP ", heat fused. 33. Deck: NC Incline: 1 -1/4 Insulation (Optional): — Any UL Classified isocyanate or polyurethane, any thickness. Base sheet: — " ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT ", self adhered. Membrane: — "POLYKOOL SA" or "XtraKool APP S SA ", self adhered. 34. Deck: NC Incline: 1 Insulation (Optional): — Any UL Classified polyisocyanate, any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR ", " ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT ", self adhered. Membrane: — "POLYBIANKO APP SAP ", self adhered. 35. Deck: NC Incline: 1 Insulation (Optional): — Polylsocyanurate, glass fiber, perlite or wood fiberboard any thickness, any combination, mechanically fastened or hot mopped in place. Base Sheet: — Type G2, "ELASTOBASE ", "MODIBASE" or "ELASTOFLEX V ", mechanically fastened. Ply sheet (Optional): — Type G2, "ELASTOBASE ", "MODIBASE" or "ELASTOFLEX V ", \' ELASTOFLEX S6 ", "POLYFLEX ", "Xtraflek APP S" or "DUFLEX" adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", "POLYFLEX G FR ", "Xtraflex APP G FR" (sand - backed) or DUFLEX .G FR" (sand- backed), adhered with Aico Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 36. Deck: C -15/32 Incline: 1 Insulation (Optional): — Polylsocyanurate (1.3 in. min), glass fiber (7/16 in. min) or perlite (3/4 in. min), mechanically fastened or hot mopped In place. Base Sheet: — Two plies Type G2, first ply mechanically fastened and the second ply fully adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", "POLYFLEX G FR ", "Xtraflex APP G FR" (sand - backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 37. Deck: C -15/32 Incline: 1 Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Insulation (Optional): — Polyisocyanurate, glass fiber, wood fiberboard, any thickness, mechanically fastened. Base sheet: — Type G2, one or more plies, mechanically fastened. Ply sheet (Optional): — Type G2, "ELASTOBASE ", " ELASTOFLEX V ", "POLYFLEX ", "Xtraflex APP S" or "DUFLEX" (sand- backed) adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", "ELASTOSHIELD TS4 FR ", "POLYFLEX G FR ", "Xtraflex APP G FR" (sand- backed) or DUFLEX G FR" (sand- backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 38. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, polyisocyanurate /perlite composite, glass fiber, perlite or wood fiberboard, any combination, any thickness or polystyrene any thichness covered with 3/4 in. perlite, 1/4 in. (min) G -P Gypsum DensDeck®, 7/16 in. glass fiber or 1 in. wood fiberboard, mechanically fastened. Base Sheet: —'Type G2, "ELASTOFEX V ", adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", "POLYFLEX G FR ", "Xtraflex APP G FR" (sand - backed) or DUFLEX G FR" (sand- backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 39. Deck: C -15/32 Incline: 1/2 Base Sheet: — Type G2, mechanically fastened. Ply Sheet: — Type G2, hot mopped. Membrane: — "TPOFLEX G FR ", heat fused. 40. Deck: C -15/32 Incline: 1 http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 7/30/2012 jGFU.R14571 - Roofing Systems Page 7 of 9 Base Sheet: — Type G2, mechanically fastened. Ply Sheet: — "DUFLEX ", hot mopped. Membrane: — "TPOFLEX G FR ", heat fused. 41. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate, periite, wood fiber or polyisocyanurate /perlite, any thickness. Base Sheet: — " POLYFLEX" or "Xtraflex APP S ", hot mopped. Membrane: — "TPOFLEX G FR ", heat fused. Class B - Fully Adhered 1. Deck: C -15/32 Incline: 1/4 Base Sheet: — Two or more layers "DUFLEX ", "Xtraflex APP S" or " POLYFLEX" (mechanically fastened or heat fused), "ELASTOBASE ", Type G2 GAF Building Materials "GAFGIas #75 ", Johns Manville "GLASBASE" or Celotex "Vaporbar GB" (mechanically fastened or hot mopped in place). Membrane: — "DUFLEX ", "DUFLEX G ", "Xtraflex APP G" or " POLYFLEX G" (modified bitumen), heat welded. 2. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Any thickness, one or more layers UL Classified periite, wood fiber, glass fiber, poiyisocyanurate, poiyisocyanurate /composite, EPS /wood fiber, EPS /perlite or EPS /composite roof insulation. Base Sheet: — One or more layers Type G1 or G2. Membrane: — One or more layers "POLYFLEX G FR ", "Xtraflex APP G FR ", " POLYFRESKO TORCH FR ", "POLYBOND ", " POLYBOND G ", "POLYFLEX ", "Xtraflex APP S ", "Xtraflex APP G" or " POLYFLEX G" (modified bitumen), heat fused. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Fields "F530 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating ", 1 -1/2 gal /sq; or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro - Grade Aluminum Roof Coating ", 1 -1/2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq. 3. Deck: C -15/32 Incline: 1 -1/2 Base Sheet: — Type G2 or "ELASTOBASE ", mechanically fastened. Ply Sheet: — "Poiygiass Base ", heat fused. Membrane: — " POLYFLEX G FR ", "Xtraflex APP G FR" or "POLYFRESKO TORCH FR" (modified bitumen), heat fused. 4. Deck: 15/32 Incline: 1 -1/2 Insulation: — Glass fiber (15/16 in. min.), mechanically fastened. Base Sheet: — Type G2 base or "ELASTOBASE ", hot mopped or mechanically fastened. Membrane: — " POLYFLEX G FR ", "Xtraflex APP G FR" or "POLYFRESKO TORCH FR" (modified bitumen), heat fused. 5. Deck: C -15/32 Incline: 1/2 Base Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX G ", "Xtraflex APP G" or "POLYBOND G ", heat fused. 6. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA ", " ELASTOFLEX SA V" or "ELASTOFLEX SA V BASE VENT ", self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet (Optional): — " POLYFLEX" or "Xtraflex APP S ", heat fused. Membrane: — " POLYFLEX SA P ", "Xtraflex APP G SA ", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", "Xtraflex SBS G SA ", " POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G" or "Xtraflex APP G ", heat fused. 7. Deck: C -15/32 Incline: 1 /2 Insulation (Optional): — Polyisocyanurate, any thickness. Barrier Board: — 1 /4 -in. (min) GP Gypsum DensDeck® or DensDeck Prime ®, mechanically fastened. Base sheet: — "ELASTOBASE" (poly /sand), mechanically fastened. Ply sheet (Optional): — " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA ", " ELASTOFLEX SA V" or "ELASTOFLEX SA V BASE VENT ", self- adhered. Membrane: — " POLYFLEX SA P ", "Xtraflex APP G SA ", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", "Xtraflex SBS G SA ", " POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G" or "Xtraflex APP G ", heat fused. 8. Deck: C -15/32 Incline: 1/4 http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 7/30/2012 1TGFU.R14571 - Roofing Systems Page 8 of 9 Base sheet (Optional): — "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet: — " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA ", " ELASTOFLEX SA V" or "ELASTOFLEX SA V BASE VENT ", self - adhered or "ELASTOBASE ", mechanically fastened. Membrane: — " POLYFLEX SA P ", "Xtraflex APP G SA ", "POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", "Xtraflex SBS G SA ", "POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G" or "Xtraflex APP G ", heat fused. 9. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Barrier Board: — 1/4, 3/8, 1/2 or 5 /8 -in. thick USG Corp "SECUROCK'' Roof Board (Type FRX -G)" Base sheet (Optional): — " ELASTOFLEX SA V PLUS ", "Xtraflex SBS Base SA ", " ELASTOFLEX SA V" or "ELASTOFLEX SA V BASE VENT ", self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet (Optional): — " POLYFLEX" or "Xtraflex APP S ", heat fused. Membrane: — " POLYFLEX SA P ", "Xtraflex APP G SA ", "POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", "Xtraflex SBS G SA ", "POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G" or "Xtraflex APP G ", heat fused. 10. Deck: C -15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — "ELASTOBASE" (poly /sand), mechanically fastened, heat fused or hot mopped. Ply Sheet (Optional): — "ELASTOBASE" (poly /sand), mechanically fastened, heat fused or hot mopped. Membrane: — " POLYFLEX SA P FR ", "POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", "POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or " POLYFLEX G FR ", "Xtraflex APP G FR ", "POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", "POLYFRESKO MOP FR ", "ELASTOSHIELD TS G FR ", heat fused or hot mopped. Class C - Fully Adhered 1. Deck: C -15/32 Incline: 2 Base Sheet: — Johns Manville "Perma Ply IV" (Type G2). Membrane: — "POLYBOND G ", " POLYFLEX G ", "Xtraflex APP G ", "POLYFRESKO TORCH FR ", "Xtraflex APP G FR" or "POLYFLEX G FR" (modifled bitumen), heat welded. Class A - Mechanically Fastened 1. Deck: NC Incline: 1 Insulation(Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite, any thickness. Membrane: — 'TOOFLEX G FR ", mechanically fastened. 2. Deck: NC Incline: 1 -1/2 Insulation: — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite, any thickness. Base Sheet: — One or more pliesType G2, hot mopped or mechanically fastened. Membrane: — "TPOFLEX G FR ", mechanically fastened. OTHER SYSTEMS 1. Deck: C -15/32 or spaced sheathing Incline: Unlimited Underlayment: — One layer Elk Corp "VersaShield ", mechanically fastened. Ply Sheet: — One ply "Polystick MTS" (self adhered). Surfacing: — Any UL Listed or Classified copper or steel standing seam panels or shingles, 26 gauge min. 2. Deck: NC Incline: Unlimited Insulation: — Any UL Classified polyisocyanurate, any thickness. Underlayment: — One ply "Polystick MTS" (self adhered). Surfacing: — Any UL Listed or Classified copper or steel standing seam panels or shingles, 26 gauge min. 1. Deck: C -15/32 MAINTENANCE AND REPAIR SYSTEMS Class A, B and C Incline: 1 Existing Roof System: — (To maintain existing Classifications) - Any Class A, B or C, uncoated, insulated or uninsulated, modified http: // database. ul. com /egi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 7/30/2012 �TGFU.R14571 - Roofing Systems Page 9 of 9 bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq. Top Coat: — "PolyBrite 70 ", applied at 1.5 gal. /sq. 2. Deck: C -15/32 Incline: 1 Existing Roof System: — (To maintain existing Classifications) - Any Class A, 8 or C, uncoated, insulated or uninsuiated, modified bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq. Top Coat: — "PolyPlus 60 ", applied at 3A -1 gal. /sq. Last Updated on 2012 -04 -18 Questions? Print this page Terms of Use Page Top © 2012 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC ". http:// database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 7/30/2012