Loading...
RF-12-2346 (2)1, gvu( U DING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: / a /5if 7 `. /0// 0! DEC 11 201Z FBC 20 K Permit No. ,; P -� Master Permit No. ROOFING Folio /Parcel #: 03,-()---02//c) Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): C62.4- L4,;1 ` L 4/- Phone #: Address: / iC 27ef City 1 t 1 Ctli7 G s" State: .// Zip: /, Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name: Address: �*� 7 /17' ,3 L.-(_,,% City: '? ✓ Gjl C Qualifier Name: State Certification or Registration #: Contact Phone #: C' Phone #:� 9c/ T State: c 9, 6(?-0- Certificate of Competency #: Email Address : °t % & 142, 41 C£( )dJ Zip: % (47 5� Phone #336 j 99 % DESIGNER: Architect/Engineer: _ Phone #: Value of Work for this Permit: $ 4 ' 6--)C) Type of Work: UAddition ❑Alteration Square/Linear F1oota of Work: '7&-f—'" L�R New epair /Replace ❑Demolition Color thru tile: ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ 2S Scanning Fee $ Radon Fee $ Notary $ Training /Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ 2'1 . Ct 0 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) di after the building permit is issued. In the absence oj'such posted notice, the inspection will s1YT be approved and a rein ecti ill be charged. ✓`; Signature 0 er or Agent The foregoing instrument was acknowledged,before me this 7' ei4 Ze.t4f /:/ day of , 20 (,, by who.ispersonailyknown to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: Signature Contractor The foregoing instrument was acknowledged before me this r/r ) day of u° id)e K 20 by M i V� G t) W who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: e MIGUEL GUERRERO *. 'a=. MY COMMISSION # D0973716 • EXPIRES March 22, 2014 J407t3ti3-01S3 FloridallotarySsrviee.00gr Sign: Print: My Commission Expir ARACELYS At HERNANDEZ MY COMMISSION # EE 192500 :<' EXPIRES: April 27 2016 J „q z,,. ' Bonded Thru Notary Public Underwriters *********************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1:// APPROVED BY Plans Examiner Structural Review (Revised 5 /2 /2012)(Revised 3/12/2012) )(Revised 06 /10 /2009)(Revised 3 /15 /09)(Revised 7/10/2007) Zoning Clerk DEC 112012 ri Shores Village RY nATF CI CO Florida Building Code 2010 Editpon,"v High Velocity Hurricane Zone Uniform Permit AppTicatwnF°jrm Section A (General informationfi �u NCE ALL FEDERAL Master Permit No. _ Process No. Contractor's Name Job Address j� ROOF CATEGORY L'3 Law Slope ❑ Mechanically Fastened Tile ❑ MortarlAdhesive Set Tlie ❑ Asphaltic ❑ Metal PanelShingles ❑ Wood Shingies!Shakes Shingles Are there ❑ Prescriptive BUR -RAS 150 Gas Vent Stacks? YesCI No ROOF TYPE Type: NaturalU LPGXU ❑ New Roof 97-.12e-Roofing ❑ Recovering ❑ Repair ❑ Maintenance . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof PIani Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. I�C��4�C�C11CC�C9 "9110EEC�E'C�:ENIPC "-r�rCCCSS C��::CCPE�r GBCN 1 ■C■■C■C ■C ■�.CCr l6 ■a...ae ■" ■■■■a■■■ Eisiii- ■e51 ■■.CrrGG -��■ 'GC■ ■■r■•P14 .rr rrrrCG■ w■ 6. ti r�r� ■■ .m■is■■s■m� imins rm ACC ■C■iilii iiii hilt a emmi" ■C ■CC ■ m. Pi , :..� C C "C " C '� M ;■ "CCC ■ ""C "C CCC C "" • C EC "C� •�'CC ■• ■ ■■ it "�■■■ ■■ r I ■ ■■ ■■ lin ■ ■■ ■■ ■■ ■■ ■ ■Ir C■ ■ ■■■ ■CC� C ■ ■un 0■■■ ■ ■CC �..0 C ■C ■C.■ mans ■ ■ ■E ■CC ■. ■■ ■CCC CC�i.Cir�. ■ ■ ■C ��, ■I 6911111 ■ "C" C " ■ ■ ■C■■C■ ■C C■ ■ ■■.■ ■■■■■ CC■�■■ ■ ,r �,immt■ ti , m"C C■■ . 11..Inp ■C■■■■ ■■ ■■ Ci■■■ CCCC■■■■ C Tomo C■"■ ,nw4IN r" ■" " " ■ "C ■E"■ CC'C"■C CC�"rrgliniC■ 11■`■1■111" � MP C CCC■ ■ C■ " "�a r IIII E rail � I- �A-- r- ■- AA-- r----- rl.AiG lllilrlr.l..GrCU 1 alinr CCCC g G"' iiiiii iii G ■ ■■ ■ r,eai min ■■■■■ ■p ■ upon Ci ■ ■ ■ms■ ipt ■CC■� ECCC ■� ■. CC CC�iCC ■ ■."■..0 ■ ■C.CC..�� ■■ ■ ■ ■ ■� ■. ii SEC CCC "1�r' C■■ ■Cr C CC■�C■ inn C "G" ::o■ CCCCC ■C `01.110CCCCC" " ■ "C :910;:41141131 ■ GCCE C'i"Cr■CC " "�iiCCil. C:� .UU 111■ I.Cr�"■■"��r�wI��� �i%L'L'::':'JGGi ■■■ ■ r p ill.:.a,E , -g----- C- C.. " ■C'- i■u■■■ ii iii 1i1i C r "■■ dug ■■ ' C ■C. i ■■ ■.r 'r..1i ■■CD .1 ■ ■s■ ■111110 ■;i11CU ■16 ' ■■l i ■ i�rl ■ C�n I -v ■■ shit' iCpli"CCC��ji�: ■m% "C op -An o n �'ma 1R .ip• ■ ■■ C. �'� ■IVO. R /ti "■■ 11 ■� ■l... ■C�r ■■■ C �ma ■ I.Ns ,.. w1i■ C�iii nom • �C■�i. MIIIMIr■i.'4 ■ME0 „C■■ ■CCC ►M•_�Ci CCCCC ui••U 111 r ■. a ■.GG ■ ■ ■ ■ �- �� ■■ ■ _ r�rr G r■ ■ r ■. ■ ■ee■C ■Crs CCCE r . -C ■ ■■ Ci1C■■■ ■■■ C1 ■■ ■ r ■ 114” "I■■ ■ ■Ii ■ ■ ■�. C Pi■ ■ ■E llUC C■GP. ■■ ■■■ C ■ ■ri ■ ■■ jPma ■ ■■C ■■ ■r1:■ C■.■■■■C C ■.■■"i5 ■■C 6 C ■ CC ■ ■U ■■■■la ''1 t i" " " 5C� C CC "CCC ICCPC C "C C C C lr CCCC poi lInumC C ., 1 C pi C Q■■ C C ■ ■C■ ■ ... ■E GI ■C" 'CCC '�., , i ■.■ ►.■ hP. C . lira C ■C ■■w ■ ■C:■ C■■ .■ ■ ■ Urr r S Cr �r ■■ hUG. ■ ■■ I ■CCC IIRUU C■■ r■C■ ■■■ p p UpC■■ ill' 1 i..ua.Nu.uuu.C.. N.aulhaumlhlC ■CCC" ; C mural C a C EC Cb I{ ■ ■C. .. NM r� ■" C C " �Ci■p■ C■iGii Miiiiiin : prr�■■►Ei�' g§■■CC iU .u• C� u.0 1 1111111111111111111 Rr.ar.:laU.UUR5 ■IIU.. g C a r ■C ■■ ■ uonun.nman■■Ch ■C ■ IC ■.��C ■. C ■CCC ■CC ■ ■CC.■ ■C. ■��.�■..�.,. ■ ■.. ■." Florida Building Code 2010 Edition High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and identify Manufacturer (If a component Is not used, Identify as'NA ) System Manufacturer. NOA No.: (2 - C./ Design Wind Pressures, From RAS 128 or Calculation: Pmax1:.3/'. Pmax2: f✓ ° �±Pmax3 9 Max. Design Pressure, From the_Spec14 N System rr Deckj2 Type: Y G Gauge/Thickness: Slope:; Anchor/Base Sheet & No. of Piy(s Anchor/Base $h t Fastener /Bonding Materiaij) Insulation Base Layer(// S7x4 9,peZia Base Insulation Size and Thickness: Bas = 1 sul • f e Fastener/Bondi y • : "al: Top insulation Layer. Fastener Spacing for Anchor /Base Sheet Attachment Field: 11r%'' oc fp Lap, # Rows ��• oc Perimeter 6 " oc © Lap, # Rows 7 @ " oc Comer." oc (4 Lap, # Rows' @ 4" • oc Number of Fasteners Per Insulation Board Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Vindicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that o l with RAS 111 and Chapter 16. Top Insulation Size and Thickness: ./1 -1 Top Insulation FastenerB ing Material: Base Sheet(s) & No. of Ply(s)// Base Sh Fn t wr/ Ply Sheet(s).& No. of Ply(s� Ply Sh :: Fas nctintj Materi J Top Top Ply FasMn aterial. Bending Mate t Surfacing: .lea. L2 '�2s Jat) F, 18 )64i0.4_ 495 )/x-PA 1` 9 Parapet Height Mean Roof Height c G1J // e, J�J�i SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, tie following items should be addressed as part of the agreement between the owner ant the contract r. T owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of ree - nt between the owner and the contractor. renailed i Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or r sh uld notify the occupants of adjacent units of roofing to be performed. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetratio of the underside of the decking may not be acceptable. This provides the option of maintaining the anc -. Ponding water: The current roof system and /or deck of the building may not drain well and may e water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectanc and performance of the new roofing system. Pounding conditions may not be evident until the o�. al roo ing system is removed. Pounding conditions should be corrected. et . Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scu . pers (wall outlets) are not provided. It may be necessary to install overflow scuppers in a dance ith the requirements of Sections R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural airflow through the I =nor of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial t► a sider additional venting which can result in extending the service life of the C°wnee .•► J�pg r /Agent's S nature Date Contractor Signature Revised on 7/9/2009 LD /02-,�' %,yam M IA M I•DADE MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 CE OF ACCETTM CE (NOA) GAF Material Corporation 361 -4Ips R _- ayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Wood Decks. ABEL . Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI DADE COUNTY APPROVED Expiration Approval Date: 04/08/09 Page 1 of 31 ROOFING SYSTEM APPROVAL Roofing Modified Bitumen SBS /APP Wood -75 psf Category: Sub - Category: Material: Deck Type: Maximum Design Pressure TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak BusterTM MatrixTM 307 Premium Asphalt Primer GAF Mineral Shield® Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 322 Elastomeric Roof Coating LeakBusterTM MatrixTM 306 LeakBuSterTM MatrixTM 204 Wet/Dry Roof Cement GAFGLAS® #75 Base Sheet GAFGLAS® #80 ULTIMATM Base Sheet GAFGLAS® Flex PIyTM 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet MIAMI DADE COUNTY APPROVED Dimensions 5, 55 gallons 60 lb. Bags 100 Ib. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (I meter) Wide 39;37" (1 meter) Wide Test Specification ASTM D41 ASTM D1863 ASTM D1227 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. ASTM D3019 ASTM D3409 ASTM D4586 ASTM D3409 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 ASTM D3909 Elastomeric roof coating. Asphalt emulsion fibered. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. Type II Asphalt impregnated and coated glass mat base sheet. Type II Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 2 of 31 Product GAFGLAS ®EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM BUR Mineral Surface Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Perforated Nailable RUBEROID® SBS Heat - WeIdTM Smooth RUBEROID® SBS Heat - WeIdTM Granule Roof MatchTM SBS Mop Granule RUBEROID® SBS HeatWe1dTM 170 FR RUBEROID® SBS Heat - WeIdTM PLUS RUBEROID® SBS Heat - WeIdTM PLUS FR RUBEROID®EnergyCap SBS Heat - WeIdTM PLUS FR RUBEROID® Modified Base Sheet RUBEROID® SBS Heat - WeIdTM 25 MIAMI.DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) Wide various 39.37" (1 meter) Wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 107 sq. ft. (9.9 m2) 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide Test Specification ASTM D3909 ASTM D3909 EnergystarTM Title 24 Compliant ASTM D3672 ASTM D4897 ASTM D3672 ASTM D4897 ASTM D6164 ASTM D6164 ASTM D6222 ASTM D5147 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D4601, Type II, UL Type G2 BUR ASTM D6164 Product Description Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT® EnergyCoteTM. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCoteTM Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Premium glass fiber reinforced SBS - modified base sheet Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 3 of 31 Product RUBEROID® Mop Granule RUBEROID® MOP Smooth RUBEROID® MOP PLUS RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROID® TORCH Smooth RUBEROID® TORCH Granule RUBEROID ®EnergyCap Torch Granule FR Roof MatchTM APP Torch Granule RUBEROID® TORCH PLUS RUBEROID® TORCH FR RUBEROID® 170FR TORCH RUBEROID® EnergyCap SBS Heat Weld Plus FR RUBEROID® 20 RUBEROID® 30 MIAMI•DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide I sq. roll 87 lbs. 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide 107 sq. ft. (9.9 m2) 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide Test Specification ASTM D6222 ASTM D5147 ASTM D6298 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 Product Description Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. A fiberglass mat reinforced, SBS modified bitumen cap membrane. SBS modified asphalt base sheet reinforce with a glass fiber mat. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 4 of 31 Product RUBEROID'F30 FR RUBEROID® EnergyCap SBS 30 FR RUBEROID® ULTRACLAD ®SBS RUBEROID® Dual FR Vent Stacks (metal and plastic) GAF Built -Up Roofing Asphalt RUBEROID® MOD Asphalt Asphalt L & Asphalt P TOPCOAT® Surface Seal SB LEAK BUSTERTM MatrixTM 715 MB Elastomeric Roofing Membrane EnergyCoteTM Coating VersaShield® TOPCOAT FireShield® MB Leak BusterTM MatrixTM 531 WeatherCoteTM Elastomeric Flashing Grade LeakBusterTM MatrixTM 201 Premium SBS Flashing Leak BusterTM MatrixTM 102 SBS Adhesive Label MIAMI.DADE COUNTY APPROVED Dimensions 39.37" (1 meter) Wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 100 lb. cartons, bulk 60 lb. kegs 5 gallons 5 gallons 2, 5 gallons 350 sq. ft roll 5, 55 gallons 5 gallons 5 gallons 5 gallons Test Specification ASTM D6298 ASTM D5147 ASTM D6163 ASTM D6163 ASTM D5147 ASTM D6164 ASTM D5147 TAS 100(A) ASTM D1929 ASTM D635 ASTM D312, Types I, II, III and IV ASTM D3412 ASTM D21 ASTM D1475 ASTM E1644 ASTM D6083 ASTM -D226 4869 Type I, II ASTM D412 ASTM D21 ASTM 1475 ASTM E1644 ASTM D3019 ASTM D3019 Product Description Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Woven fiberglass mat coated with Polymer modified asphalt surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. One -way valve vent used to relieve built - up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Interply mopping and surfacing asphalt SEBS modified asphalt Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Highly reflective elastomeric coating Non - Asphaltic Fiberglass -Based Underlayment Elastomeric roofing membrane Surface coating for smooth surfaced and mineral surfaced roofs. Cold Applied Modified SEES Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04 /08/09 Page 5 of 31 Product Leak BusterTM MatrixTM 202 SBS Flashing Cement Label Leak BusterTM MatrixTM 203 Plastic Roof Cement Label Leak BusterTM MatrixTM 103 Cold Process Adhesive Label LeakBusterTM MatrixTM 304 Non - Fibered Aluminum Roof Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane TOPCOAT® MB Plus MIAMI•DADE COUNTY APPROVED Dimensions 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5, 55 gallons Test Specification ASTM D4586 ASTM D4586 Product Description Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement ASTM D3019 Cold Applied Asphalt Adhesive. ASTM D2824, Type 1 ASTM D412 ASTM B117 ASTM C794 ASTM G21 FTMS 141.6271 ASTM D2196 ASTM D1475 ASTM E1644 ASTM D412, ASTM D21, ASTM D1475 ASTM E1644 Non - fibered. Aluminum pigmented, asphalt roof coating. Surface coating for smooth surfaced and mineral surfaced roofs. Water - based, low VOC, sprayable polymeric liquid, which cures to form a seamless rubber membrane. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 6 of 31 APPROVED INSULATIONS: Product Name EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM Strip EnergyGuardTM Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Polylso EnergyGuardTM RA, RN EnergyGuardTM Composite, RA DensDeck® DensDeck Prime® DensDeck DuraGuardTM Structodek® Structodek® TD SecurockTM APPROVED FASTENERS: Fastener Product Number Name 1. Drill -TecTM #12 Standard, #14 and #15 extra Heavy Duty Fastener, Heavy Duty Roofing Fastener 2. Drill -TecTM ASAP 3. Drill -TecTM CR Base Sheet Fastener and Plate 4. Drill -TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate MIAMI-DADE COUNTY APPROVED Table 2 Product Description Fiberboard insulation Perlite insulation board Cut perlite board Perlite recover board Tapered perlite board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate /wood fiberboard or perlite composite Water resistant gypsum board Water resistant gypsum board Water resistant gypsum board Wood fiber insulation board Flame Resistant High Density Wood Fiber board. Fiber reinforced roof board TABLE 3 Product Description Dimensions Insulation fastener and Various Base Play fastener for steel, wood & concrete decks. Pre- assembled Drill -TecTM Various Fasteners and metal and plastic plates. Base sheet fastening Various assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume® coated 3" Square steel plate. Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. G -P Gypsum Corp. G -P Gypsum Corp. G -P Gypsum Corp Knight Celotex Knight- Celotex USG Corporation Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. 3" and 3 1/2" GAF Materials Corp. 3" and 3 '/z" GAF Materials Corp. OMG NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 7 of 31 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories Trinity Engineering Test Identifier Description Date 3029832 4470 -TAS 114 05/11/07 3010215 4470 - TAS 114 03/01/01 3001276 4470 - TAS 114 01/28/99 1B9A8.AM 4470 - TAS 114 09/04/97 3D4Q2.AM 4470 - TAS 114 04/30/97 ODIA8.AM 4470 - TAS 114 04/01/98 TGFU.R19254 UL 790 10/27/06 4483.04 97 -1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF- 020 -02 -01 ASTM D 249 02/01/02 ASTM D 4977 IRT -ARCON Inc. Trinity I ERD MIAMI•DADE COUNTY APPROVED 02 -005 TAS 114 03/01/02 02 -014 TAS 114 04/08/02 01 -039 TAS 114 03/01/02 G6850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 11 /05/08 NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04 /08/09 Page 8 of 31 Membrane Type: SBS /SBS Cold Applied Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type D(1): Insulation and Base sheet simultaneously attached All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM RA, EnergyGuardTM Composite, Structodek ®, Structodek® TD, EnergyGuardTM Fiberboard Minimum 1" thick N/A N/A Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) derlayment or SecurockTM. Base Sheet: , GLA ® #75 AFGLAS® #80 ULTIMATM Base Sheet, AFGLAS'' STRATAVEN " EliminatorTM Perforated or RUBEROID® 20 base Sheet applied over the loose laktinsulatidtivaifir side laps mechanically fastened to deck as described below; Fastening Options: Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates are installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maxir►wm ne n Pressure —60 psf, See General • 'tation #7) Dril TecTM #12 standar #14 or # 15 Screws a 3 "Plates n 4 rows 12" o.c. One row ow i in tic 2' side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates are installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional On�or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6 sheet, GAFGLAS 80 UltimaTM, RUBEROID® MOP Smooth oI(RUBEROID'20 adhered in a full moppingQ.i.approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. MIAMI•DADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11 /06/13 Approval Date: 04/08/09 Page 23 of 31 Membrane: Surfacing: On or more plies of RUBEROID® MOP Smooth,/UBEROID® Mop 170 F UBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop Plus Granule, RUBEROID® 20, RUBEROID® 30, RUBEROID ®EnergyCap SBS 30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID® ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of-20-40 lbs. /sq. Or, One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID ® 20, RUBEROID® 30, RUBEROID® EnergyCapTM SBS 30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID® ULTRACLAD® SBS in Leak BusterTM MatrixTM 102 SBS Adhesive at an application rate of 1 -2 gal. /sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above MIAMMDADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11 /06/13 Approval Date: 04/08/09 Page 24 of 31 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply TM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4" Dens Deck or 1" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and /or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 09 -0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 31 of 31 • 2009 ROOFING MATERIALS AND SYSTEMS DIRECTORY 218 ROOF- COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Membrane: One or more plies "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing: Gravel. 7. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or More layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, wood fiber /polyisocyanurate composite. Base Sheet: Two or more plies Type G2 or Type G3. Ply Sheet (Optional): One or more plies Type G1. Membrane: Onaor more plies "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing: "Karnak No. 97" appled at 1' to 3 -gal /100 -ft2 or gravel. 8. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. minimum polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, 1 -1/2 in. minimum. Base Sheet (Optional): One or more plies Type Gl or Type G2 or Type G3. Membrane: One or more plies "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing: Grundy "AL MB Aluminum Roof Coating" applied at 1 to 2 -gal /100 -ft2. 9. Deck: C -15/32 , Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. minimum, polyisocyanurate, urethane, perlite /polyisocyanurate com- posite, perlite /urethane composite, phenolic, 1 -1/2 in. minimum. Base Sheet: One or more plies Type G2 "GAFGLAS #75 Base Sheet ", or "Tri -Ply #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more plies Type Gl " GAFGLAS Ply 4 ", "Tri- Ply"Ply 4 ", or "GAFGLAS Ply 6 ", hot mopped in place. Membrane: "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR ". Surfacing (Optional): "GAF Fibered Aluminum Coating" applied at 11/2-gal/ 100 -ft2 or "GAF Weather Coat Emulsion" applied at 3 -gal /100 -ft2. 10. Deck: C -15/3'2 Incline: 1/2 Insulation (Optional): Perlite, fiber glas &, polyisocyanu'rate, uret ane or perlite /polyisocyanurate composite. Base Sheet: One or more layers Type G2 "GAFGLAS #75 Base Sheet ", "Tri -Ply #75 Base Sheet ", or Type G3 "OAFGLAS Mineral Surfaced Cap Sheet ", or "Tri -Ply Mineral Surfaced Cap Sheet", hot mopped or mechanically fastened. Ply Sheet (Optional): One or more plies Type G1, hot mopped in place. Membrane: ' "Ruberoid. Mop 170 FR" or ";Ruberoid SBS Dual FR" or "Ruberoid Mop FR ". 32 Incline: 1/2 Insulation (Optional): Perlite, fiber glass, polyisocyanurate, urethane or perlite /polyisocyanurate composite, butt offset a minimum of 6 -in. from plywood deck joints. - Base Sheet: One or more plies Type G2 "GAFGLAS #75 Base Sheet ", "Tri -Ply #75 Base Sheet ", or Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ", or "Tri-Ply Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened. Ply Sheet (Optional): One or more plies Type Gl, hot mopped in place. Membrane: One ply "Ruberoid Torah Smooth" or "Ruberoid Mop Smooth ". Membrane: One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR ". 12. Deck: NC Incline: 1 Insulation (Optional): Perlite, fiber glass, wood fiber, polyisocyanurate, urethane or perlite /polyisocyanurate composite. Base Sheet: One or more layers Type G2 "GAFGLAS #75 Base Sheet ", "Tri -Ply #75 Base Sheet ", or Type G3 "GAFGLAS 'Mineral Surfaced Cap Sheet ", or "Tri -Ply Mineral Surfaced Cap Sheet ", hot mopped or mechanically fastened. Ply Sheet (Optional): One or more plies Type Gl, hot mopped in place. Membrane: One ply "Ruberoid Mop 170 FR" or "Ruberoid SBS Dual FR" or "Ruberoid Mop FR ". 13. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, fiber glass, wood fiber, polyisocyanurate, urethane or perlite /polyisocyanurate composite. ROOF - COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Base Sheet (Optional): One or more plies Type G2 or Ty sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more plies Type G1, hot mopp Membrane: One ply "Ruberoid Torch Smooth" (smooth), Mop Smooth ". Membrane: One ply "Ruberoid Mop 170 FR" or "Ruberoi FR" or "Ruberoid Mop FR ". 414. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fit cyanurate, urethane or perlite /polyisocyanurate composite, ness. Base Sheet: One or more plies Type G1 "GAFGLAS Ply 4 ", 4 ", or "GAFGLAS Ply 6" or Type G2 "GAFGLAS #75 Bass "Tri -Ply #75 Base Sheet ", hot mopped or adhered with Kanu "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive 100 -ft2. Membrane: One ply "Ruberoid Mop 170 FR" or "Ruberoi FR" or "Ruberoid Mop FR ", hot mopped or adhered Chemical "No. 81" or Gibson-Homan "No. 6160" cold applied 11/2-gal /100 -ft2. 15. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber, perlit any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies Type G2 "GAFGLAS #75 Ba: "Tri -Ply #75 Base Sheet ", hot mopped or mechanically fast€ Membrane: One or more plies "Ruberoid 30 FR" or "Rul gyCap SBS 30 FR" hot mopped in place. 16. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber, pert fiber any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies Type G2 "GAFGLAS #75 Ba "Tri -Ply #75 Base Sheet ", hot mopped or mechanically fast€ Ply Sheet: One or more plies "Ruberoid 20 ", hot mopped Membrane: One or more plies "Ruberoid 30 FR" or "Rube: Cap SBS 30 FR" hot mopped in place. 17. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Fiber glass or perlite, mechanically Base Sheet: One or more plies Type G2, hot mopped or r fastened. Ply Sheet: fastened. Membrane: "Ruberoid 30" or "Ruberoid Modified Cap Sh mopped in place. Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Alu Coating" at 1 to 2 -gal /100 -ft2. 18. Deck: NC Incline: 1/4 Insulation (Optional): Polyisocyanurate, perlite, glass fil fiber, 2 -in. maximum. Base Sheet: Type 15 asphalt organic felt or Type G2, i fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid Torch Granule 1" (modified bitum Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Alu Coating" at 1 to 2 -gal /100 -ft2. 19. Deck: C -15/32 Incline: 1/4 Insulation: Two layers glass fiber (butt joints in insula minimum of 6 -in. from plywood deck butt joints, 1 in. eaci Base Sheet: Type G2, mechanically fastened or adher roofing asphalt. Membrane: "Ruberoid Torch Granule 1" (modified bitum Surfacing: Karnak Chemical "Karnak No. 97 Fibratec Asphalt Roof Coating" at 1 to 2 -gal /100 -ft2. 20. Deck: NC Incline: 1/4 Membrane: "Ruberoid Torch Granule 1" (modified bitum Surfacing: Karnak Chemical "Karnak No. 97 Fibratec Asphalt Roof Coating" at 1 to 2 -gal /100 -ft2. 21. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, wood fiber or glass fiber, 1-i mechanically fastened or adhered with hot roofing asphalt Base Sheet: Type G2 or "Flex Base 60" (modified bitumE cally fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid Torch Granule 1 ", heat fused. Two or more plies Type Gl, hot mopped or r LOOK FOR THE UL MARK ON PRODUCT