Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-12-2061
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 182537 Permit Number: RF -10 -12 -2061 Scheduled Inspection Date: February 14, 2013 Inspector: Bruhn, Norman Owner: GLINN, MacDAM & DENISE Job Address: 1201 NE 102 Street Miami Shores, FL 33138- Project: <NONE> Contractor: PRECISION ROOFING CORP Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1132050250160 Phone: (305)822 -9969 Building Department Comments RE ROOF TO FLAT ROOF ONLY Infractio Passed Comments INSPECTOR COMMENTS False Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 181866. CREATED AS REINSPECTION FOR INSP- 180997. Drip metal must lap at joints no less than 4" Provide engineering for gutter attached through roofing material. Remove roofing material from gable wall and flash and counterflash per RAS 111 February 13, 2013 For Inspections please call: (305)762 -4949 Page 6 of 22 Miami Shores Village Building Department RE: Permit # 12f to -I Z Q(0 ( INSPECTION AFFIDAVIT I J OR n,) ,., f) ( Q LL G licensed as a (n) Contractor / Engineer / Architect, 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: 11 11(01 1 Z (Print name and circle License Type) FS 468 Building Inspector License #:CCC - q 3 7 On or about 1.1 /1(07( Z , I did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at 1,20 ( K1 e t.O 2- 57- 14 /114-A4 g1+9 s (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this ((-3, Notary Public, Sate of Florida at Large day 4 CARLOS A URBINA Notary Public - State of Florida My Comm. Expires Jul 31, 2015 Commission # EE 116290 *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 THIS IS NOT A BILL — DO NOT PAY RECEIPT tENEWAL 695931 -7 STATE# CCC1329365 BUSifTT17AMi / LOCATION PRECISION ROOFING CORP 2646 W 77 PL 33016 HIALEAH FIRST -CLASS U.S. POSTAGE I PAID MIAMI, FL PERMIT NO. 231 OWNER PRECISION ROOFING CORP Sec. Type of Business WORKER /S �..... - 19,6 SE..ECIALTY BUILDING CONTRACTOR 23 BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING ZONING LAWS DO NOT FORWARD COUNTY OR CITIES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE NO°T A CCERTI CATION O PRECISION ROOFING CORP THE HOLDERS DUALIFICA- JULIO MARTINEZ PRES 2646 W 77 FL PAYMENT MI ADfi °c EIVED TAX HIALEAH FL 33016 COLLECTOR: 09/06/2012 02250005002 000084.00 SEE OTHER SIDE llllllllllll1IIIII111,' I, I, ll jl ,IIl1IIilllillilllll,lil,llIl,r STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487 -1395 1940 NORTH MONROE STREET TALLAHASSEE FL 32399 -0783 TALLET, JOANNA PRECISION ROOFING CORP 2646 WEST 77TH PLACE HIALEAH FL 33016 Congratulations! With this license you become one of the nearly one million Floridians: licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better Far information about our Services, please log onto www.myflartdallcense.corn There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new Fran ETIFI$D und zuvi tms of Ch. 8.i a.tet, AIM 31, 2014. i;.120827ri170 A CO RED aA xi e itiD . G CROPM ATENTED Prig SE L120a2'J'tl!170 TCH NU he Rf iPI NG; CON1 CTOR (stied be47f+'Ir trader the provisions sf Chap as ration date: AUG' .3I, 201 CISI . R(' 0 C{F 6_WN;ST 77TH PLACE RICK SCOTT GOVERNOR !LAY AS REQUIRED BY LA. , KEN LAAWS( SEBCRETAR3 ACOREY CERTIFICATE OF LIABILITY INSURANCE lg/ EI7DOD ) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Frank H. Furman, Inc. 1314 East Atlantic Blvd. P . O . Box 1 927 Pompano Beach FL 33061 CONTACT Laura Buratt NAME: PH NN .Ext): (954) 943 -5050 (A/ ,NO): (954)942 -6310 E -MAIL ADDRESS: /aura @furmaninsurance.corn INSURER(S) AFFORDING COVERAGE NAIC # INSURERA:Starr Indemnity & Liability 38318 INSURED Precision Roofing Corp 2646 W 77th Place Hialeah FL 33016 INSURERB:Travelers Casualty Ins Co of 19046 INSURERCBridgefield Employers Ins Co 10701 INSURERD: $ 1,000,000 INSURER E : 50 000 $ r INSURER F : COVERAGES CERTIFICATE NUMBER:2012 -13 GL /AU /WC REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSR SUBR W VD POLICY NUMBER POLICY EFF (MM/DD/YYYY) POLICY EXP (MM/DD/YYYY) LIMITS A GENERAL X LIABILITY COMMERCIAL GENERAL LIABILITY X X SIPGGL0018501 6/14/2012 °� 6/14/2013 EACH OCCURRENCE $ 1,000,000 DAMAGE RENTED PREMISES l (Ea a occurrence) 50 000 $ r CLAIMS -MADE X OCCUR MED EXP (Any one person) $ 5,000 PERSONAL &ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE 7 POLICY X LIMIT APPLIES PRO JECT PER: LOC PRODUCTS - COMP /OP AGG $ 2,000,000 $ B AUTOMOBILE X X LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS X SCHEDULED AUTOS NON -OWNED AUTOS X x BA8B168550 6/28/2012 6/28/2013 COMBINED SINGLE LIMIT (Ea accdent) $ 1,000,000 BODILY INJURY (Per person) $ BODILYINJURY(Peraccident) $ PROPERTY DAMAGE (Per accident) $ $ UMBRELLA LIAB EXCESS LIAB _ OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ $ DED RETENT ON $ C WORKERS AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER /EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y/N N / A 83038032 6/20/2012 •r 6/20/2013 WC STATU- 0TH- TORY LIMITS ER E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYEE $ 1,000,000 E.L. DISEASE - POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) CERTIFICATE HOLDER CANCELLATION Miami Shores Village Building Department 10050 N.E. 2nd Avenue Miami Shores, Fl 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Frank Furman, Jr /LB ACORD 25 (2010/05) INS025 r'ninnst m © 1988-2010 ACORD CORPORATION. All rights reserved. Tho Arnim nsmu s.nrl Innn *ro rnnicfnrnrl msrlrc of A( non 111111111111111111111111111111111111111111111 NOTICE OF COMMENCEMENT o :FN 2012R0772766 Bk 28333 F's 0063; (1py A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION RECORDED 10/29/2012 15 :16:00 HARVEY RUVIN? CLERK OF COURT / MIAMI -DACE COUNTY? FLORIDA PERMIT NO. TAX FOLIO NO. `/- S1 'Y- yes-- Of () LAST PAGE STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street I address: /40/ Brie: ,oz 5 r X/(44'( »/ s, re 33/3S' 2. Description of improvement: 3. Owner(s) riaine and addres i/e- -An « ry / f2-' / A'6 "Z 5 f flr��.t -t S 'ft 3 3 /, 8 Interest in u/,��� Inter property: Name and address of fee simple titleholder: 4. Contractor's name and address: PRECISION ROOFING CORP. Pi2eCepeti4/ 2646 WEST 77 PL HIALEAH, FL 33016 PH: (305) 822 -9969 rfL/4g, - 02&'i w77 /!/ p4 o )ff2z'' 1 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ 6. Lender's name and address: STATE OF FLORIDA, COUNTY OF DADE I HEREBY CERTIFY that th1j tru9 copy ON 7. Persons within the state of Florida designated by Owrae►` provided by Section 713.13(1)(a)7., Florida Statut.Tl`it Name and Address: HARVEY By >t 5 r docume ? Oiffi ^jal Seal. ;, of OTC' it .,ounty Courts D.C. 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner f Print Owner's Name ` '` ' 1 k 6 `Inn Prepared by Sworn to and subscribed before Notary Public: Print Notary's Name: My commission expires: day of Cabi 20 e Address: A niNA Notary Put iC - State of Florida 015 My Comm. Expires Jul 31, Commission If EE 116290 /2ICC(Stb� Avga 1Z1f420%ILlft. • Miami Shores Village Building Department /0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION OCT 3 6 2012 FBC 20 Permit No. 3 12.7(2—a0/1 Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: 490 / ,Vt /O Z 5r City: Miami Shores County: Miami Dade Zip: 3 3 1 3g Folio/Parcel #: 0-3205-- 3205 -- 0 ZS-- 0(4,0 Is the Building Historically Designated: Yes NO 1C Flood Zone: OWNER: Name (Fee Simple Titleholder): Y'e InSE Qthidti Phone #: (S) 16( t(q Address: /cz0/ /vr IQZSr City: P1(6 Ml" S -S State: /0/3 Tenant/Lessee Name: Email: Phone #: Zip: 3 3 l 3 C2 CONTRACTOR: Company Name: PRECISION ROOFING CORP. Phone #: 305 -822 -9969 Address: 2646 WEST 77 PL City: HIALEAH State: FL Zip: 33016 Qualifier Name: JOANNA TALLET Phone #: 305 - 822 -9969 State Certification or Registration #: CCC 1329365 Certificate of Competency #: Contact Phone #: 305 - 822 -9969 Email Address: JOANNA @PRECISION- ROOFING.COM DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ '13O0 �"' Square/Linear Footage of Work: 96 2 Type of Work: ❑Addition ❑Alteration New IiiRepair/Replace /L e -%.90F To -,2o r As F aety Description of Work: ❑Demolition Color thru tile: ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* ** * * * * * * * * * * * * * * *** * * * * * * * * * * ** r'' 7 Submittal Fee $ Permit Fee $ ., ` ! CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ ra' Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. I absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of who is �� N/J rsonally known tome or o has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: attio5 My Commission Expires: 7,4, /// Signature Contractor c� � The foregoing instrument was acknowledged before me thisdr7 day of I4ic/v, 20 (Z%by �ANNO 1 ba-67 who is personal nown to me o)titho has produced as identification and who did take an oath. Commission # EE 116290 NOTARY PUBLIC: Si Pr' 15 _ ...RBINA Notary Public - State of Flori My Comm. Expires Jul 31, 2 0 * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * ** * * ** * * * * * * * * * ** APPROVED BY Plans Examiner ** Structural Review (Revised 3 /12 /2012)(Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Commission E * * * * * * * * * ** CARLOS A. URBINA :l Notary Public - State of Florida My Comm. Expires Jul 31, 2015 Commission # EE 116290 Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: Ip(2 2 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: 'TQ,E115.. GI t i rn Property Address: I20 t roe 10 2 S- -ree• 4 Roofing Permit Number: Dear Building Official: I f-Def US ., < t n certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature -.1) N1S&-- 6' ix/A; Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes andisays that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this s/ day of (/ At •r Notary Public, Sate of Florida at Large CARLOS A. URBINA Notary Public - State of Florida My Comm. Expires Jul 31, 2015 of Commission # EE 116290 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FB nor a 1.94 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Property Information Map My Home Miami -Dade County, Florida Page 1 of 1 Property Information Map Aerial Photography - 2012 0 This map was created on 10/30/2012 12:19:23 AM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. Close 114 ft Summary Details: Folio No.: 11- 3205- 025 -0160 Property: 1201 NE 102 ST Mailing TEENA S DEBERRY Address: 1 Living Units: 517 FAIRWAY DRIVE Adj Sq Footage: FLORENCE SC Lot Size: 29501- Property Information: Primary Zone: 1400 SGL FAMILY - 3001 -3250 SQ CLUC: 0001 RESIDENTIAL - SINGLE FAMILY Beds /Baths: 2/2 Floors: 1 Living Units: 1 Adj Sq Footage: 2,380 Lot Size: 11,690.90 SQ FT Year Built: 1951 $0/$393,804 PB 42 -25 BAY BREEZE City: SEC MIAMI SHORES Legal LOT 8 BLK 186 LOT Description: SIZE 89.930 X 130 COC 22795 -2392 10 2004 4 OR 22795 -2392 1004 01 Assessment Information: Year: 2012 2011 Land Value: $202,040 $168,367 Building Value: $191,764 $192,966 Market Value: $393,804 $361,333 Assessed Value: $393,804 $209,675 Exemption Information: Year: 2012 2011 Homestead: $0 $25,000 2nd Homestead: NO YES Widow: $0 $500 Taxable Value Information: Year: 2012 2011 $0 Applied Applied Taxing Authority: Exemption/ Taxable Exemption/ Taxable disqualified as a result of Value: Value: Regional: $0/$393,804 $50,500/ $159,175 County: $0/$393,804 $50,500/ $159,175 City: $0/$393,804 $50,500/ $159,175 School Board: $0/$393,804 $25,500/ $184,175 Sale Information: Sale Date: 10/2004 Sale Amount: $0 Sale O /R: 22795 -2392 Sales Sales which are Qualification disqualified as a result of Description: examination of the deed View Additional Sales http:// gisims2 .miamidade.gov /myhome /printmap. asp? mapurl= http: / /gisims2.miamidade.g... 10/30/2012 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form F f ^` ? ; i L Section A (General Information) Master Permit No. Contractor's Name: PRECISION ROOFING CORP. Job Address: 1201 NE 102 ST MIAMI SHORES, FL 33138 ROOF CATEGORY U Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile Process No. )(",20(c) f ❑Asphaltic Shingles ❑ New Roof El Metal Panel /Shingles ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 GAS VENT: ❑ YES m NO ROOF TYPE Re -Roof ['Recovering ❑ Repair rea (SF) ROOF SYSTEM INFORMATION Steep Sloped Area (SF) N/A Section B (Roof Plan) : Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and o w s aims. Include dimensions of sections and levels; clearly identify dimensions of elevated pre sure zones and location of parapets. n Maintenance Total (SF) 962 t- FIAT ROOF ONLY Miami APPROVED ZONING DEPT BLDG DEPT Shores Vi !age ?oz. pt vie ez, PATE li'Te IZ 3UDJEOT TO OOMf'L NCE WITH ALL FED RAL STATE AND CC-MINTY RULES AND REGULATIONS Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and Identity Manufacturer (If a component is not used, identify as "NA ") System Manufacturer: GAF NOA No.: 09- 0224.01 Design Wind Pressures, From RAS 128 or Calculations: Pmaxl: 49.2 Pmax2 82.6 Pmax3: 124.3 Max. Design Pressure, from the specific NOA System: -52.5 PSF Deck: Type: PLYWOOD DECK Gauge/Thickness: 5/8 = 19/32 Slope: 1/2:12 Anchor /Base Sheet & No. of Ply (s): N/A Anchor /Base Sheet Fastener /Bonding Material: N/A Insulation Base Layer: N/A Base Insulation Size and Thickness: N/A Base Insulation Fastener /Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener /Bonding Material: N/A Base Sheet(s) & No. of Ply(s): Base Sheet Fastener /Bonding Material: Ply Sheet(s) & No. of Ply(s): BASE SHEET #75 Ply Sheet Fastener /Bonding Material: 1 1/4 R/S NAILS AND 1 5/8 TIN CAPS Top Ply: GAF RUBEROID 170 FR MOPPED IN PLACE Top Ply Fastener /Bonding Material: STEEP ASPHALT TYPE IV Surfacing: RUBEROID MOP 170 FR Fastener Spacing for Anchor /Base Sheet Attachment Field: 9 "oc @ Lap, # Rows 2 @ 9 "oc Perimeter: 6 "oc @ Lap, #Rows 4 © 6 "oc Corner: 6 "oc @ Lap, #Row 4 @ 6 "oc Number of Fasteners Per Insulation Board Field: N/A Perimeter: N/A Corner: N/A Illustrate Components Noted and Details as Applicable: Wood blocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. N/A • A 9" RUBEROID STRIP Parapet Height 10' 3X3 GALV 26 GA. GAF #75 BASE SHEET GAF RUBEROID MOP 170 FR WHITE Mean Roof Height • • Owner's, Notification Form HVHZ 2010 "rfret,vvr,g E.kE L "v •a Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's /Agent's Signature: - _�. Date: / Contractor's Signature: Property Address: Permit Number: M I A M !•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI-DADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 1 of 31 Membrane Type: SBS /SBS Cold Applied Deck Type 1: Wood, Non- insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM Base sheet: GAFGLAS® #80 ULTIMA TM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- WeldTM Smooth or RUBEROID® SBS Heat- WeldTM 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any Options: of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure –45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure –4S ps , See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure –52.5 psf, See General Limitation #7) —' GAFGLAS® #80 ULTIMATM, RUBEROID®20, RUBEROID ®Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure –60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure –60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure –60 psf, See General Limitation #7) MIAMI•DADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 27 of 31 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6, GLAS® #80, RUBEROID® MOP Smooth or RUBEROID® 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. Membrane: Surfacing: One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR RUBEROID® Mop Granule, Roof MatchTM SBS Mop anu e, RUB • I b Mop Plus Granule, RUBEROID®20, RUBEROID®30, RUBEROID®EnergyCap SBS 30 FR RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. Or, One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID®20, RUBEROID® 30, RUBEROID®EnergyCap SBS 30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID® ULTRACLAD® SBS in Leak BusterTM MatrixTM 102 SBS Adhesive at an application rate of 1 -2 gal. /sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. 3. Leak BusterTM MatrixTM303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT® MB+, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at I to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above MIAMI•DADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 28 of 31 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply 'm 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" Dens Deck or ' /2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and /or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 31 of 31 UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R1306 Roofing Systems See General Information for Roofing Systems GAF MATERIALS CORP 1361 ALPS RD WAYNE, NJ 07470 USA R1306 "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. '/ -in. thick (minimum) gypsum board or 1/4-in. thick (min) G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" are to offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Multiple plies of "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "Tri -Ply® Ply 6" may be adhered to G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" in hot roofing asphalt. "EnergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. "GAF Stratavent® EliminatorTM Venting Base Sheet (Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLAS® Perlite Insulation" may be utilized as a cover board over "EverGuard" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive. Polystyrene referenced in any of the following Classfications include "EnergyGuard EPS Insulation ". References to glass fiber insulation include "EnergyGuard Fiberglass Insulation ". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ( "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet ", or "GAFGLAS® #80 ULTIMA ") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4 ", or "GAFGLAS® Ply 6 ") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent® EliminatorTM Venting Base Sheet (Perforated)" or "GAF Stratavent® EliminatorTM Venting Base Sheet (Nailable)." Perforated to be loose laid or mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or "GAFGLAS® #80 ULTIMA" or "GAF Stratavent© EliminatorTM Venting Base Sheet (Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6 ") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLAS® Flashing" or "Ruberoid®" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE®" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1 -in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C -15/32 thick roof decks. The use of polystyrene insulation board between minimum 3 /4 -in. thick perlite board and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for polyisocyanuratee board in the following Class A, B or C systems. "EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". "GAFGLAS® #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS® Flex Ply 6" and "Tri -Ply® Ultra - Flexible Ply 6" are suitable alternates to "GAFGLAS® Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Fireshield MB" at 21/2 to 3 -gal /100 -ft2. "Ruberoid® Dual Smooth" may be used as an alternate to "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT" "Ruberoid® Mop Smooth 1.5" may be used as an alternate to "Ruberoid® Mop Smooth" SINGLE PLY MEMBRANE ROOFING SYSTEMS (MODIFIED BITUMEN) Unless otherwise indicated phenolic insulation may be used in any of the following systems. Unless otherwise indicated any of the following Single Ply Membrane Systems may utilize multiple layers of Ruberoid® Membrane. "GAF Premium Aluminum Roof Coating" may be used on any of the following Classifications with inclines not exceeding 1/2-in. "GAF Weater Coat Emulsion" may be used on any of the following noncombustible Classifications with inclines not exceeding 1/2-in. "Ruberoid® Modified Bitumen Adhesive" or Monsey Corp. "MBA Gold" or Karnak "No. 81" adhesives may be used in any of the following noncombustible deck Classifications. Tropical Asphalt "No. 711 AF" adhesive may be used in any of the following Classifications. "GAFGLAS® #80 Premium Base Sheet" may be used in any of the following systems. (Optional) Noncombustible deck classifications are applicable for use over combustible (15/32 in. minimum plywood) decks when / -in. (minimum) gypsum board or 1/4-in. (minimum) G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" are used directly over the deck with all joints staggered 6 -in. (minimum) from plywood joints. A vapor barrier may be optionally installed under all systems utilizing "EverGuard" insulation. "EverGuard" insulation is an acceptable alternate in any polyisocyanurate insulation of the following systems. "GAFGLAS® Perlite" may be used as an option over "EverGuard" insulation. "GAFGLAS® Stratavent Perforated Base Sheet "may be utilized as an additional ply in any of the following systems. The following membranes may be used interchangeably within their own group: A. "Ruberoid® Torch Granule" or "Ruberoid® Torch Granule Plus" or "Ruberoid® Torch Granule 1" or "Ruberoid© Torch 180" or "ROOFMatchTM APP Modified Granular" or "Tri -Ply® TP -4G ". B. "Ruberoid® Mop Smooth" or "Ruberoid® SBS Heat Weld Smooth" or "Ruberoid® 601 Cap Plus" or "Ruberoid® 30." C. "Ruberoid® Mop Granule" or "Flex PRF" or "Ruberoid® Mop Plus Granule" or "Ruberoid® SBS Heat Weld Granule" or "Ruberoid® SBS Heat Weld Plus" or "ROOFMatchTM SBS Modified Granular" or "Tri -Ply® SBS Modified Bitumen Membrane ". D. "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" E. "Ruberoid® 30 FR" or "Ruberoid® 30 FR HT" or "Ruberoid® EnergyCapTM SBS 30 FR" F. "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® SBS Heat Weld 25." G. "Ruberoid® Torch FR" or "Brai Supreme Plus APP Granule FR" or "GBSP -250 FR" or "Brai Supreme -APP Granule FR." H. "Ruberoid® SBS Heat Weld 170 FR ", "Ruberoid® EnergyCapTM TM SBS Heat Weld Plus FR" or "Ruberoid© SBS Heat Weld Plus FR" I. "Ruberoid® Torch Smooth" or "Tri -Ply® TP -4" J. "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Dual Smooth" K. "Ruberoid® Mop Smooth" or "Ruberoid® Mop Smooth 1.5 "Unless otherwise indicated, the Modified Bitumen (Granule) membrane may be surfaced with "Fireshield MB" at 21/2 to 3.0- ga1/100 -ft2, and the incline of the resultant system would be increased to a 3/4-in. incline. But if the incline of the Classified system is greater than a 3/4-in. incline, the incline of the roofing system would be maintained when surfaced with "Fireshield MB" at 21/2 to 3.0- gal /100 -ft2. Unless otherwise indicated "Ruberoid® EnergyCapTM SBS 30 FR" is an acceptable alternate for "Ruberoid® 30 FR" or "Ruberoid® 30 FR HT" or "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" in any applicable Classification. Class A 10. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Perlite, fiber glass, polyisocyanurate, urethane or perlite /polyisocyanurate composite. Base Sheet: — One or more layers Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place. Membrane: — "Ruberoid® Mop 170 FR" or "Ruberoid® Dual FR" or "Ruberoid® Mop FR" or "Ruberoid® EnergyCapTM Mop Plus FR." Last Updated on 2012 -02 -21 © 2012 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC ".