Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC16-2167
August 30,2016 vARTWM Project Name: Starbucks Coffee,95th St.&2nd 'Ave. Project Address: 9488 NE 2nd Ave. Miami Shores,FL 33138 Miami-Dade County Attention: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores,Florida 33138 Tel:(305)795.2204 Fax:(305)756.8972 Permit#:16-2167 RE:Response to Starbucks Remodel Plan Review Comments Please refer to enclosed drawings and the list below in response to the plan review comments dated August 8,2016 for the additional items required for plan review approval.All revisions to the drawings are clouded and identified as"REV 01—AHJ Comments"dated 08-30-16. Building Director-Ismael Naranjo,B.O.,CFM Comment 1 Outside agencies approval required.DERM,Miami Dade Fire Department,Health Department,and Miami Dade Water and Sewer. Response:Acknowledged Comment 2 Sheet G-0001.Construction type is mark as 1-v.Provide construction type as per chapter 6 of the 2014 Florida Building Code Building. O r- O r. o � Response:Construction type has been corrected to V. Comment 3 Provide compliance method in accordance with section 301 of the 2014 Florida Building Code Existing Building. 0 Q Response:2014 Florida Building Code Existing Building:Chapter 3;Section m 301;Paragraph 301.1.2 Work area compliance method. Note has been added to Sheet G-0001. W 7 O O N o Comment 4 a z Provide level of alteration as per chapter 5 of the 2014 Florida Building Code n 0 -+ CO oExisting Building. a Response:2014 Florida Building Code Existing Building:Chapter 5;Section c0i 504 Alteration-Level 2. Note has been added to Sheet G-0001. "i a W Z 6+ S Q G. O vyd Comment 5 1210.2.2 Walls and partitions. Walls and partitions within 2 feet(610 mm)of service sinks,urinals and water closets shall have a smooth,hard,nonabsorbent surface,to a height of not less than 4 feet(1219 mm)above the floor,and except for structural elements,the materials used in such walls shall be of a type that is not adversely affected by moisture. Response:Acknowledge all proposed finishes within noted area comply as required. Refer to Wall Finish Plan and Interior Elevations. Boxed note has been added to Sheet 1-2101 and 1-4102 Comment 6 Miami Shores Village Zoning approval required. Response:Acknowledged Plumbing-Rafael Hernandez �� Comment 1 Need Derm and Health Dept.reviews. S Response:DERM Approved. Starbucks falls under Department of Agriculture Jurisdiction,not Hotel&Restaurants.Plan Review is strictly voluntary,per code previously attached to front of plans. Electrical—Michael Devaney,Chief Electrical Inspector Comment 1 Need circuit Numbers with panel schedules. Response:Please refer to revised Power Plan,E-1101&E-1102,for circuit numbers added. Please refer also to revised Plan E-6001 for revised panel schedules. Please let us know if you need any additional information or have any questions. Best regards, Brian Bush I Project Designer WD Partners brian.bush OwdPartners.com Page 2 of 2 September 06,2016 PARTRERB Project Name: Starbucks Coffee,95h St.&2ndth Ave. Project Address: 9488 NE 2"d Ave. Miami Shores,FL 33138 Miami-Dade County RE:Revision 02 Summary The following information supplements and amends the original Construction Drawings and Specification,and shall become a part of the Contract Documents. To include all changes labeled"REV 02- Client Comments"dated 09.06.16. 1. Modified the Soffit depth and added new Soffit Detail. • Affected sheet:1-1108 Best regards, Brian Bush I Project Designer WD Partners brian.bushOwdgartners.com 0 , 0 , o n M ID m ID do m rx v v w w � w rx a W J 0 o ` m 0 M 2 y > O O = N © z Q � O � V 7i1 c � Q • y� Y Florida Department of griculture. and Consumer Secs ices CILARLES 11. BROWS(\. Caninii•sitmer The Capitol • 'lallahas--wv. H.32399-4-0X0 Please Respond to: Division of Food Safety 3125 Conner Blvd.,C-18 Tallatiassee,FL 32399-1650 (850) 245-552D AM.:Q A.&T Specialist •••••• 6023-26th Sf yW P@1B#266.. . .' � Ij • • • • (941)311366 •• • •••••• •••• •••• • • March 30,2005 .... .... ..... ...... . ..... RE: Plan Review for Food Establishments •• •• V.•• •••••• • Dear Building and Plumbing Oficial: •••••• • Chapter 500 Flori&Statutes(ES.)does not give the •• •• • Department of Agricultue and'.. Consumer Services the authority to review and read plans except on a voluntary basis.Although the Department does not e e opportunity to review Don of equipment or a constructton of the facility beforehand,the food establishment seeking a permit to operate,is still responsible for meeting all of the requirements established under Chapter 500.The following is section 500.12(2)F.S., concerning the enclosed guideline: (2)When any person applies for a building permit to construct;convert,or remodel any food establishment;food outlet,or retail food store,the authority issuing such permit shall make available to the applicant a pig statement;provided by the department, regarding the applicable sanitation requirements for such establishments.A building permitting authority,or mumicipality ar county under whose jurisdiction a building P authorily opemtes,may not be held liable for a food establishment,food outlet,or retail food store that does not comply with the applicable sanitation requirements due to failure of the building permitting authority to provide the information as provided in the subsection. a)The department shall fuimish,for distribution,a statement that includes the checklist to be used by the food inspector in any preoperational inspections to assure that the food establishment is constructed and equipped to meet the applicable sanitary guidelines.Such preoperational inspection shall be a prarequisite for obtamhig a food permit in accordance with this section b)The department may provide assistance,when requested by the applicant,in the review of any construction or remodeling plans for fel establishments.The department may charge a fee far such assistance which covers the cost of providing the assistance and which shall be deposited in the General Inspection Trust Fund for use in fiinding the food safety program. FWb Fla. Florida agriculture and Forest Products - 97Rillj #% r-, 1',nr Nlnee �l :a I' onnn +�; r Florida Department of.lgric•ulture and Consumer`er%ices CHARLES If. BRONSON_ Commissioner 1;z00Z Thr t_:apit.i a Tallahas ee�. Fl,323919-08M ��i+�s.d1�Jc-•.�taie.f 1.u c)A building permitting authority or other subdivision of local government may not wire the department to approve construction or remodeling plans for food • establishments and.retail food stores as a condition of any permit or license at level. .... ...... We need your help and expertise to assure that food establisimients c&ft:'with ... :.... regulations prior to operation. We appreciate your cooperation and if you have arty QvOons'....' ..... please feel free to call me at the number listed above. • ...... .. . ..... .. .. . .. ...... sincerely, ...... . CHARLES H.BRONSON •• •••, ; COMMISSIONER OF AGRICULTURE •..' Aggie R.Hale Faivirornmental Manager AH/bb Eresh Via. Florida Agriculture and Forest Products T ,qi H 1 ( l 1 11 n t (1 r t+ m i l d , , + l" 1' 11 11 fl tT1 r COMcheck Software Version 4.0.4.0 Interior Lighting Compliance Certificate Project Information Energy Code: 2014 Florida Building Code, Energy Conservation Project Title: Starbucks 95th ST. &2nd Ave. Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor. 9450 NE 2nd AVE Lais Brito Gregory Holman, P.E. Miami Shores„ FL 33138 Starbucks Coffee Company WD Partners 95 Merrick Way 7007 Discover Blvd Suite 650 Dublin,OH 43017 Coral Gables, FL 33134 614-634-7304 (305) 529-5316 Ibrito@starbucks.com Allowed Interior Lighting Power A B C .""p Area Category Floor Area Qllowfld Aflb%Ved Wattle 0 0 (ft2) Waifs/142 .00(o x C) '• 000000 .• • 000000 1-Coffee House(Common Space Types:Family dining area) 1473 J 02A.. .2062 • . 0000 Total Allewsd Watts= •••2062 • • • • • . 00000000 00.00 0000.. .. Proposed Interior Lighting Power ' . 0000. A B ..C..' D: '.0' E 0000.. Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ 046400 Fixture • (C X D) .' Fixture Fktu?es: Watt . 000000 0000.. Coffee House(Common Space Types:Family dining area 1473 sq.ft.) • :0000: LED 2:12907:Can Light:Other: 1 '17 ' 16'':'• 2550 0 LED 3:14360:Pendant:Other: 1 3 10' 30 LED 5:16590:Sconce:Other. 1 2 5 10 LED 6:14896:Picture Light:Other. 1 3 12 36 * LED 7:15081:Can Light:Other: 1 3 11 33 Track lighting 1:(E):Existing Track: Wattage based on 32 feet of track 0 0 960 960 Linear Fluorescent 1:(E):Existing Troffer:48"T8 32W(Super T8):Electronic: 3 3 86 258 Total Proposed Watts= 1582 .........;, 0000...-0000. .. .:........._....;,, ..... .... <. Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this ermit application.The proposed interior lighting systems have been designed to meet the 2014 Florida Building Cod Con ervation requirements in COMcheck Version 4.0.4.0 and to comply with the mandatory requirements listed i io ecklist. G r UB Iwai }� JUL Y Y 2016 B Name-Title Sig Date Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187 FL 7964 95th St and 2nd_St Miami\03-Build\02- Page 1 of 6 Arc h_E n g\D es i g n D ata\E I ectri c a l\STRST0187.c ck b COMcheck Software Version 4.0.4.0 Inspection Checklist Energy Code: 2014 Florida Building Code, Energy Conservation _ Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. mon Rla Ilrtt �pl xi1: + t1tsstatll�'x1s �� C405.7 'Plans,specifications,and/or ❑Complies 'Requirement will be met. [PR17]1 :calculations provide all information <❑Does Not with which compliance can be determined for the electrical systems ❑Not Observable :and equipment and document where ❑Not Applicable :exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors sized in :accordance with approved plans with maximum drop of 2%and branch circuits sized for maximum drop of 3%. • • C103.2 ::Plans,specifications,and/or ;❑Complies Requirement will be met. • • • • [PR4]1 calculations provide all information :❑Does Not with which compliance can be •••;•• " ' see** determined for the interior lighting ❑Not Observable and electrical systems and equipment :❑Not Applicable ;••'• and document where exceptions to • �' '....' ..••• :the standard are claimed.Information • provided should include interior *fee** :0. 0• 69606 lighting power calculations,wattage of; 'bulbs and ballasts,transformers and •••••• • • control devices. : : • • ••..: Additional Comments/Assumptions: : .'. ::9000: 1 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187-FL-7964-95th-St-and-2nd St_Miami\03-Build\02- Page 2 of 6 Arc h_E n g\Desig n Data\Electrica I\STRST0187.cck r Xg \ C4C5 Automatic controls to shut off all ;❑Complies 'Requirement will be met. building lighting installed in all ;❑Does Not CL2] buildings. ;❑Not Observable': ❑Not Applicable ir4M.1: "Independent lighting controls installed ;❑Complies :Requirement will be met. per approved lighting plans and all :❑Does Not manual controls readily accessible and ;❑Not Observable: visible to occupants. ❑Not Applicable C405.2.1 Lighting controls installed to uniformly;❑Complies :Requirement will be met. 2 reduce the lighting load by at least ;❑Does Not [EL1511 50%. ,❑Not Observable: ❑Not Applicable 0405.2,2 ;;Daylight zones provided with ❑Complies :Exception: Requirement does not apply. 3individual controls that control the :❑Does Not ELl.61,z ;lights independent of general area ;lighting. t❑Not Observable ;❑Not Applicable 0405.2.3 ;Sleeping units have at least one ;❑Complies :Exception: Requirement does not apply. JEL1713 master switch at the main entry door ❑Does Not ;that controls wired luminaires and switched receptacles. ❑Not Observable ❑Not Applicable •••••• C405.2.2. Occupancy sensors installed in '❑Complies Requirement will be met. 2 :required spaces. ❑Does Not " ' 0 . . •. [EL18110000.. .. • 0000. E❑Not Observable 0000 • ❑Not Applicable ••••• C405.2.2. Primarysidelightedareasare °❑Complies Exception: RequirementdoeSiVIAply. •0• 0• 0••.0 3 :equipped with required lighting '❑Does Not ' [EL20)1 controls. """ • • ❑Not Observable . ' ' ' ' ' . .. . .. 0000. ❑Not Applicable 000000 . 0- C405.2.2. 'Enclosed spaces with daylight area f❑Complies Exception: Requirement does not apply. • • •••••• 3 under skylights and rooftop monitors ;❑Does Not . • •0 0• • • [EL21]1 are equipped with required lighting UNot Observable ••0• ; •0. ;""; controls. :: • • • ❑Not Applicable •• • C405.2.3 Separate lighting control devices for ;❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable:2 ❑Not Applicable 0405.3 <Fluorescent luminaires with odd E❑Complies Requirement will be met. tEL1913 numbered lamp configurations that C❑Does Not are within 10 feet center to center(if recess mounted)or are within 1 foot ❑Not Observable edge to edge(if pendant or surface ❑Not Applicable mounted)shall be tandem wired. C405.4 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 face. ❑Does Not ❑Not Observable:: ❑Not Applicable C405.2.3 :Additional interior lighting power ❑Complies Requirement will be met. [ELB)1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and ❑Not Observable separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3'"Low Impact(Tier 3) Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187 FL 7964 95th St and 2nd_St_Miami\03-Build\02- Page 3 of 6 Arch Eng\DesignData\Electrical\STRST0187.cck • • 1 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187 FL 7964 95th St and 2nd_St_Miami\03-Build\02- Page 4 of 6 Arc h_E n g\Des i g n D ata\E I ectric a l\STRST0187.c ck *MW M . �� . �� �`►�'i+i�t! ��i�' ` \� �� II"4' i' S�lkt�,1'IGiCk�lE�i >....,..., .... ,M 0,000, C4O$ 5. Furnished as-built drawings for ❑Complies :Requirement will be met. 1 =electric power systems within 30 days ;❑Does Not V-11OP of system acceptance. j❑Not Observable: ;❑Not Applicable Furnished O&M instructions for ❑Complies 'Requirement will be met. MazS. systems and equipment to the ;❑Does Not 2 building owner or designated j:Fi17F representative. (❑Not Observable ❑Not Applicable E C405.5.2 :Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F[18]1 lighting power is consistent with what E❑Does Not Js shown on the approved lighting ❑Not Observable plans,demonstrating proposed watts are less than or equal to allowed '❑Not Applicable watts. C408.3 Lighting systems have been tested to '❑Complies :Requirement will be met. (FI33]1 ensure proper calibration,adjustment, t❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable C406 :Efficient HVAC performance,efficient ;❑Complies :Requirement will be met. [FI34]1 lighting system,or on-site supply of �❑Does Not ••• renewable energy consistent with ❑Not Observable ' • :what is shown the approved plans. • • •••• ••••9 ❑Not Applicable •.•• �• • •• Additional Comments/Assumptions: ••';" '• """ 0000.. 0000 9999 . . 0000 9999 0000. 0000.. .. .. .. . .. 0000.. 0000.. . . . ego:*. 00.99. 0 .. 9 9009 9 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187 FL 7964 95th St and 2nd St Miami\03-Build\02- Page 5 of 6 Arch_Eng\D es i g n D ata\E I ectric a l\STRST0187.cck 0000 . . .•.. 0000.. .. • .• . 0000.. 0000 0000 . . . 0000 0.00 ..... ...... .. . 0000. . . 0000 .• 0000.. ...... . • . . . . See*:* 0000.. . . 0000.. .. . .... . • Project Title: Starbucks 95th ST.&2nd Ave. Report date: 07/07/16 Data filename: P:\STR\ST\STRST0187 FL_7964_95th St and 2nd_St_Miami\03-Build\02- Page 6 of 6 Arch Eng\DesignData\Electrical\STRST0187.cck