Loading...
MC-16-2017 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-263612 Permit Number: MC-7-16-2017 Inspection Date: December 14,2016 Permit Type: Mechanical - Residential Inspector: Perez,JanPierre Inspection Type: Final Owner: CORDERO, CARLOS AND NICHELE Work Classification: A/C Replacement Job Address:301 NEI 01 Street Miami Shores, FL 33138-2468 Phone Number Parcel Number 1132060135180 Project: <NONE> Contractor: QUALITY COOLING SYSTEM Phone: 305-255-9439 Building Department Comments EXACT CHANGE OUT OF A A/C 4 TON CONDENSER InfPassed Comments AND AIR HANDLER UNIT INSPECTOR COMMENTS False Inspector Comments Passed IV] Failed El Correction ❑ Needed Re-Inspection a Fee No Additional Inspections can be scheduled until re-inspection fee is paid. For Inspections please call: (305)762-4949 December 14,2016 Page 1 of 1 f i e Miami Shores Village 10050 N.E.2nd Avenue NE Miami Shores,FL 33138-0000 �� 1 Phone: (305)795-2204 zkh �l251101'� : Expiration: 01/21/2017 Project Address Parcel Number Applicant 301 NE 101 Street 1132060135180 CARLOS AND NICHELE CORDEI Miami Shores, FL 33138-2468 Block: Lot: Owner Information Address Phone Cell CARLOS AND NICHELE CORDERO 301 NE 101 Street MIAMI SHORES FL 33138- 301 NE 101 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 3,900.00 QUALITY COOLING SYSTEM 305-255-9439 (305)970-1935 Total Sq Feet: 00 Tons:4 Available Inspections: Additional Info:EXACT CHANGE OUT OF A A/C 4 TON CON Inspection Type: Classification:Residential Final Approved:In Review Review Mechanical Comments: Date Approved::In Review Date Denied: Type of Work: Scanning:3 Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $2.40 Invoice# MC-7-16-60652 DBPR Fee $2.05 07/19/2016 Check#:2525 $50.00 $106.00 DCA Fee $2.05 Education Surcharge $0.80 07/25/2016 Check#:2536 $ 106.00 $0.00 Permit Fee $136.50 Scanning Fee $9.00 Technology Fee $3.20 Total: $156.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,RO ING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing informati accurate nd that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,I authorize the above-n d cont r cto o do the work stated. July 25,2016 Authorized Signature:Owner / Applicant % Contractor / Agent Date Building Department Copy July 25,2016 1 NVMiami Shores Village � JUL g 2016 � , Building Department MOW I(,-- 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 /Y BUILDING Master Permit No. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION RENEWAL [--]PLUMBING 0 MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 301 NE 101 Street City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-3206-013-5180 Is the Building Historically Designated:Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): Nichele S Bansee Cordero Phone#: 305-308-4911 Address: 301 NE 101 Street City: Miami Shores State: Florida Zip: 33138 Tenant/Lessee Name: n/a Phone#: Email: t(nigal64@gmail.com CONTRACTOR:Company Name: Quality Cooling Systems, Inc Phone#: 305-255-9439 Address: 14629 SW 104th Streety111 t 3tii City. Miami State: Florida Zip: 33186 Qualifier Name: Roger W Parris Phone#: 305-970-1935 State Certification or Registration#: CAC042713 Certificate of Competency#: DESIGNER:Architect/Engineer: n/a Phone#: Address: City: State: Zip: Value of Work for this Permit:$ -319002" Square/Linear Footage of Work: Type of Work: F-1Addition El Alteration El New Q Repair/Replace 1:1 Demolition Description of Work: Exact change out of AC Condenser and Air Handler Unit �C�9A c(T�-/ q-ThoJ) Specify color of color thru tile: Submittal Fee$ 0V Permit Fee L9 L CCF$ - '7 CO/CC$ Scanning Fee$ Radon Fee,$ DBBPPR$$ 0—° ®S Notary$ Technology Fee$ --� Training/Education Fee$ ® ` �✓� Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ ro d (Revised02/24/2014) Bonding Oompand❑Name(if applicable) Bonding Oxnpand❑Addre® City State 2lp Mortgage Lender'❑Name(if applicable) Mortgage Lender'❑Addre® City State Zp Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has oommeraaed prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELEMI ICC RJJMStNQ SIGN$ POOL$ RJRNAaFA BOILER $IEATE F64 TANIQ AIRCONDITIONEiiS ETC.... O❑NERSAFFIDMAT I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and mnirx. "D ARNI NG TO 00 NBA YOUR FAI LUFZE TO REMFID A NOIR OF COM M ENCEUI ENT MAY RE9JLT IN YOUR PAYING TWICE FOR I M PROVE1ll BUTS TO YOUR PROPERTY. IF YOU INTEND TO 09TAJ N R NANaNQ CONaJLT WITH YOUR LENDER GRAN AT MMEY BffOF;F-ANG YOUR NOTICEOF COM M ENCEIH ENT" Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500,the applicant must promise in good faith that a copy of the notice of commenoernerit and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven () days after the building permit is issued. In the of such posted notice, the inspection will not be approved and a reinspection fee will be urged. Signature ! i Pte( 9 OVVNBRor AGENT OONTPACTOR The foregoinginstru t was acknowledged before me this The foregoing instrument wasacknonrledgedbeforemethis day of 20 by Y: C Aay of 20 �(,, by who is personally known to who is personally known to me or who has produced 6 i 2z -b 31-Z7 7 q L Q me o who has produced �NL_ as identification and who did take an oath. identification and who did take an oath. NOTARY RJBIJC NOTARY PUStJC Sign: Sgn: Print: lit z- Print: Z. �:ae�;•..% ANA JEZ �`;;:•P!� ARiAIN.wnwii s « W COMMISSION#FF 956873 W COlNMISSION#FF OW EXPIRES:Apn719, 0 '� « a°'gip�pda�F ! Tffv 9*t NotrySuvices per' �� EXPOiES:Apr819,2020 202 ►ewad�' 9oA0idTANBadyetNOt«yS�e1 «w•r•wwrswrr,►trot:ws, r*w,e�,e,e•*«rw,ew• •www* ••w«,r**«•,tw.s•*•ss*..«•.•wwww*•tr.w*.�w**wf*«s«•.rr«.w*«*s*wwien•r.ww APPS BY � ons E�lrniner Zoning Structured Peview aerk (Fbvised04J24/2014) R.�es y Miami Shores Village Building Department ... p,.." 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel:(305)795.2204 Fax:(305)756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change-out must be on its own data sheet.Multiple units on single sheets are not acceptable. Job Address(where the work is being done):301 N E 101 Street City: Miami Shores Village County: Miami Dade Zip Code: 33138 ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means:YES❑ NO 0 ARHI Sheet Attached:YES NO❑ Contract Attached:YES ❑� UNIT BEING REPLACED DATA NEW UNIT GOODMAN MANUFACTURER RHEEM AR49 AHU or PKG. UNIT MODEL# RH1T4821JA CK-48A1 COND.UNIT MODEL# RA1648 10 KW HEAT 10 4 NOM TONS 4 AHU 58 CU32 PKG 58-32 1)M.C.A AHU 56CU 25 PKG 58-25 AHU 60 CU45 PKG 60-45 2)M.O.P AHU 60CU 40 PKG so-40 AHU CU PKG 230v 3)VOLTS AHU CU PKG 230v PKG UNIT / / PKG UNIT 12 EER/SEER 16 YES NO REPLACING DUCTS YES NO NO YES NO REPLACING THERMOSTAT YES NO NO YES NO NEW 4"CONCRETE SLAB YES NO YES YES NO N/A NEW ROOF STAND YES NO N/A YES NO NEW RETURN PLENUM BOX YES NO NO 1. Minimum Circuit Ampacity(Wire Size): #6 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 60amp 3. Voltage of Circuit(208/240/480): 230 Volt 4. Size Disconnecting Means: 60amp Contractor's Company N me: Qualitypooling Systems, Inc Phone: 305-255-9439 State Certificate or ration No. C 042713 Certificate of Competency No. Signatu Date: 18 uaiiflees signature) (Revised02/24/2014) PROPOSAL QUALITY COOLING SYSTEMS,INC. AJC SALES-SERVICE-INSTALLATION STATE LICENSED&INSURED CAC#042713 14629 SW 104 ST,UNIT 300 MIAMI,FL. 33186 PHONE:(305)2554439 FAX:(305)255-5.514 www.qualitycooling.com PROPOSAL SUBMITTED TO PHONE AND FAX DATE NICHBLE BANSEE CORDERO PH 305»508-4911 07-14-2016 email:trinigal64@gmail.com STREET JOB NAME 301 NE 101"STREET AJC REPLACEMENT with Duct Modifications CITY,STATE AND ZIP CODE JOB LOCATION MIAMI SHORES-FL.33133 CITY OF MIAMI SHORES,FLORIDA WE HEREBY SUBMIT SPECIFICATIONS AND ESTIMATES FOR: TO SUPPLY AND INSTALL(1)ONE RHEEM 4 TON SPLIT AIR.CONDITIONING SYSTEM WITH OZONE FRIENDLY 410A REFRIGERANT AND(1)ONE FACTORY MATCHING VERTICALLY MOUNTED AIR HANDLER UNIT. New RHEEM 4.OTon Classic Series R410 Condenser 4 TON with RH1T Series Air Handler rated @ 16.00 SEER 3,950.00 LESS DEALER CASH REBATE (goad thru Aug I5'4 2015) 350.00 LESS FPL REBATE - 150.00 ADD FOR EXPEDITING PERMIT PLUS PERMIT FEES +450.00 DUE FROM CUSTOMER 3A0.00 WARRANTY COVERS 10 YEAR COMPRESSOR; 10 YEAR PARTS AND(1)YEAR ON LABOR. ADD$519.00 FOR OPTION TO ADD 2"0 THRU I VH YEAR FACTORY LABOR WARRANTY. JOB INCLUDES PARTS,MATERIAL,AND REMOVAL AND DISPOSAL OF EXISTING EQUIPMENT.RECONNECT TO EXISTING DUCTWORK,EXTENDED ELECTRICAL AND CONDENSATE DRAINLINE.NEW RETURN DUCTING FROM FLOOR GRILLE,NEW AHU STANDIBOX,DRAIN FLOAT SWITCH,COIL MOUNTED UV LIGHT,AIR HANDLER STAND, SECURING CONDENSER TO NEW APPROVED CONCRETE PAD,R410A RETROFIT REFRIGERANT LINE FLUSH,PURGE AND VACUUM SYSTEMS,START-UP AND TEST. LABOR,TAXES AND FACTORY WARRANTY. JOB EXCLUDES OR NOT APPLICABLE TO ANY DUCT CLEANING,CEILING GRID/WORK, DRYWALLJCONSTRUCTION WORK,ANY NEW DRYER EXHAUST,THERMOSTAT,ANY NEW ELECTRICAL AND ANY CONCRETE,ROOF OR OTHER BUILDING PENETRATIONS, PATCHING,SEALING OR PAINTING. WE PROPOSED HEREBY TO FURNISH MATERIAL AND LABOR-COMPLETE IN ACCORDANCE WITH ABOVE SPECIFICATIONS,FOR THE SUM OF: THREE THOUSAND NINE HUNDRED DOLLARS AND 00JI00 $3,900.00 ACCEPTANCE OF PROPOSAL x '`°, fop ' RINT 7 DATE � coil This combination qualifies for a Federal Energy At RAMP Efficiency Tax Credit when placed in service al CERTIFIED'. between Feb 17,2009 and Dec 31,2016. Off 'P1&x,%Rdu%A' Ra0t I AHRI Certified Reference Number: 7943535 Date: 5/19/2016 Product: Split System:Air-Cooled Condensing Unit, Coll with Blower Outdoor Unit Model Number: RA1648AJ1 Indoor Unit Model Number: RH1T4821STAN Manufacturer: RHEEM SALES COMPANY, INC. Trade/Brand name: RHEEM; RUUD Region:All (AK,AL,AR,AZ,CA,CO, CT, DC, DE, FL,GA, HI, ID,IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY,OH,OK,OR, PA, RI,SC,SD,TN,TX, UT,VA,VT,WA,WV,WI,WY, U.S.Territories) Region Note: Central air conditioners manufactured prior to January 1,2015,are eligible to be Installed in all regions until June 30,2016. Beginning July 1,2016, central air conditioners can only be Installed In region(s)for which they meet the regional efficiency requirement. Series namie: . . 6� Manu„s 'firm le r the rating of thls system combinAltiOn,is RNR M SALES COMPANY,INC. s Rated: �if�C ws in'accordaricew, 'AHRI Stall t�ti 81240.2009 mr,kinlit iry Air-+ rtdit( r�lrt and Air-Source Heat '> pi nt-pct subject to x tic of.r�ating�urac by AHRI»spons rigid; tndepel +r atrt,third party Gcnlin Cpa ,Btuh}: 4W0 5E" F Ratlrig(Ccinfiing): -16.00 IEER Rating(Cooling): Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER •• 00: • • • • • •• AHRI does not endorse the product(s)listed on this Certificate and makes no representations iwairaaties orguarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability f& amd*I at kitldtriitlgbut dl the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid eyy for n"els gnd cpnfigurgtipns listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certifical•slall only b%usg jfpr Individug.l,pejs°nal and confidential reference purposes.The contents of this Certificate may no*inrvhole or in pact,be reproduced;copiec(18isseminated; entered Into a computer database;or otherwise utilized,in any form or tftstgtar dj by jpy I=tl%ns,except.for t heVsOr's Individual, AM P and confidential reference. . •• • • •• • e • AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION •• • • • ••• • &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.shridirectory.org,click on"Verify Certificate”link we make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above,and the Certificate No.,which is listed at bottom right..• • e . . e,►s • • 13108159079590306D ©2014 Air-Conditioning,Heating,and Refrigeration Institute• •0• iCERTIRC ATE NO.: This combination qualifies for a Federal Energy ■ Efficiency Tax Credit when placed in service between Feb 17,2009 and Dec 31,2016. e Uertm fit;cK V U101"T"P F"roducA Ratings AHRI Certified Reference Number: 7943535 Date: 7/1/2016 Product:Split System:Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: RA1648AJ1 Indoor Unit Model Number: RH1T4821STAN Manufacturer: RHEEM SALES COMPANY, INC. Trade/Brand name: RHEEM; RUUD Region:All(AK,AL,AR,AZ,CA,CO, CT, DC, DE, FL,GA, HI, ID, IL, IA,IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY,OH,OK, OR, PA, RI,SC, SD,TN,TX, UT,VA,VT,WA,WV,WI,WY, U.S.Territories) Region Note: Central air conditioners manufactured prior to January 1,2015,are eligible to be Installed In all regions until June 30,2016. Beginning July 1,2016, central air conditioners can only be Installed In region(s)for which they meet the regional efficiency requirement. Series name. Manufootu res slbie; or file rating of this system combination Ise RHEirN( LE$CC)MPANY,INC. Rated'a:�llattow>l;in'8ttcardance with AHRI Startidarct 2101240-2008,fibr Unitary Air--60 tiliioning and Air•Source Heat Pump IElqulpi r t.aix( u t to v rificatiosn of ruing accuracy by AHRI-sponsored, litdepertdont,third party>keslting: Cq lln Capacity(Btu,h): 450Ct0 EER Rating(Cool#ng): 13.00 SEER Rating(Coollhg): 16.00 IEER Rating (Cooling): Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER •• 000 • • • • • •• AHRI does not endorse the product(s)listed on this Certificate and makes nee represenCitio*r*Ziva;arle&orlu4antees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability fo►damages ort arW kind arts"Out oMe use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings an&VAd w0or%Ael1grt'h cdnfi$u%%9Rs listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and AM confidential reference purposes.The contents of this Certificate may not•I%&Yhal&ar in paa!be n1p:o1luced;co4egJIVeminated; entered Into a computer database;or otherwise utilized,In any form or warmer op by any means,except for the4osWs individual, personal and confidential reference. •••• • • • • ••• • • •• •• • AIR-CONDITIONING.HEATING, • • • CERTIFICATE VERIFICATION •• • • • ••• • &REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better- and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above,and the Certificate No.,which is listed at bottom righty•• • • • :[1 ;• 131118855243723021 ©2014 Air-Conditioning,Heating,and Refrigeration Institlte 'W61 0=4 NO.: RHEEM SALES COMPANY, INC. , ,�, „ 54B�INARDO,D.E Y AND STEE ALUMINUM TIE-DOWN CLIPS: AT GRADE MOUNTED APPLICA[��`�O > WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY U 4 (- 11.0001 * 6 V3515, 3 CEe,._ 1 V30 OMS' 3 0.3i3u-1—}�—�- 0.750" ����C:•.......... B. o+n s fl 'Ili i' nn s/O11AL Z� 8 0 18-GA ASTM AA6E53 PAINTED O EL Z m w CABINETRY O O W 3 N �� O •... mQWAl > > O ,� • • ••• '90.0• • • e • 5tt•I.TO G BUT 51M.l'0�)BUT O c •• • 000" ON OPP.FAC[ ON DPP.FA4L' �+ •••••• 0 Z • ••• A C • 'y 0.187' 00000• • �+ • 0000 40 • • CONCRETE O 0••••• :••• • d • • CONCRETE SUPPORTING SUPPORTING STRUCTURE BY 0.306' •41:•0• • • STRUCTURE BY B OTHERS,TYP. D TYP, O • • 004. U 6 OTHERS,TYP. CONTROL BOX •• •• 0006 � • • 1 MECHANICAL UNIT 2 MECHANICAL UNIT , 000:00 J •- 1 N.T.S. FRONT ISOMETRIC 1 N.T.S. BACKISOMETRIC TIE-DOWN CLIP THESE ISOMETRICS ARE INTENDED FOR • • •0••• x • DIAGRAMMATICAL PURPOSES ONLY;ALTERNATE RHEEM MIAMI TECH CUP:14GA(0.07)ASTM A653 • • • LLI 0 0a•� UNITS LISTED HEREIN MAY VARY IN APPEARANCE Fu-90 KSI STEEL(CUTD70)OR 0.080' 0 0 0 0000 • p (4)-010 NTERNALPOST 5052-1132 ALUMINUM(CUTDAIO),MIAMI 0••0 c SMP,PERTYPADJACENT TO CONTROL BOX TECH KIT•RRCUTDLK OR RRCUTDALKUVER gg Ips - gG PANEL TYP. CLI B 137.25° t P© NIT BASE "u NIT BASE 00 UNIT BASE i8 ANCHORPER PAN PAN PAN SCHEDULE 3000 PSI MIN CONCRETE BY ® Oo-© O ul A DIM. cN CONTROL p OTHERS,TYP. OC _ - — - :;_K OX idl CUP OFFSET DIMENSION SHALL 00 ®&Q ARE SIM BE TA(fEN FROM THIS SIDE ONLh _�...�-e-. E AND OCCUR ON DATUM FACE OPP.FACES 3 TIE-DOWN CLIPS 4 TIE-DOWN CLIP LAYOUT T LBQlKs Pa 1 N.T.S. ELEVATION 1 N.T.S. PLAN 15-2543GA MACNd�•.•iT7M�� BGIBt N.TB. ANCHOR SCHEDULE: TIE-DOWN CLIP OFFSETS: APPLrABLE MODELS 555 Su.. DESCRIMCIADSM.1 4.50'MAX OFFSET FROM DATUM FACE RA1842A,RAISO,RA1660,4P1360, 38,7 e• g (1)•1/4.0 CARBON STEEL SIMPSON STRONG BOLT2,IV,'MIN EMBED TO RD1480,RP1B48,481448,RP160. Q°yp •7� CONCRM: conKRF 3•MrN.mGE DISTANCE,3•MIN.SPACING To ANY ADIACENTANCHOR. DIM.2 30.00°MIN OFFSET FROM DATUM FACE 481480,RAlUA1748,RNUA1780, 0 30 THICK MIN, 11)-1/4 0 CARBON STEEL POKERS WEDGE BOLT+,2I•EMBED TO CONCRETE,3• DIM.3 31.00°MIN OFFSET FROM DATUM FACE RA/UA2Q40,RM)A2080,RPNP1748, p! Sp 3000 PSI MIND MIN.EDGE DISTANCE,3'MIN.SPACING 7o ANY ADwCInT ANCHOR. RPNP1780,RPNP2048,RPNP2080, (LJ? 2 SUPPORTING CONCRETE SUBSTRATE DEPTH SHALL BE A MINIMUM 1.SrANCHOR EMBED. DIM•4 13.00°MAX OFFSET FROM DATUM FACE `Zr CCCC— EITHER ANCHOR FROM THIS SCHEDULE MAYBE USED FOR INSTALLATION. Mi®��E MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamldade.gov/economy Rheem Sales Company,Inc. 5600 Old Greenwood Rd. Fort Smith,AR 72917 SCOPE:This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION:Mechanical Unit Steel and Aluminum Tie-Down Clips for Grade and Rooftop Applicationg APPROVAL DOCUMENT:Drawing No. 15-2543GA,titled"Wind Load Certification of Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips:At Grade and Roof Mounted Applications",sheets 1 through 7 of 7,dated 05/14/2015,revised on 11/20/2015,prepared by Engineering Express,signed and sealed by Frank L.Bennardo,P.E.,bearing the Miami-Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state, model/series,and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. .. *s o . . . . • .. INSPECTION:A copy of this entire NOA shall4%e proAleate the�sei ��'tL-manufacturer or its distributors and shall be available for inspection at the job site at thg*1equ�e*:° gHuIleiin�g Offl*icl. This NOA consists of this page 1 and evidence page E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. • 006 04 •tl• • . J • •• • • • • • • • • NOA No.15-0903.08 M1AMIOD DE COUNTY • •r 00* Expiration Date:February 25,2021 � !•4��r� � • Approval Date:February 2 P 2016 . 0:0, •• age 1 • •• •r• ••f •••• ••• •• ••• • • Rlteem Sales Company,Inc. NOTICE OF ACCEPTANCE: . EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 15-2543GA,titled"Wind Load Certification of Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips: At Grade and Roof Mounted Applications",sheets 1 through 7 of 7,dated 05/14/2015,revised on 11/20/2015, prepared by Engineering Express,signed and sealed by Frank L. Bennardo, P.E. B. TESTS 1. Test report on Uniform Static Air Pressure Test per FBC, TAS 202-94 along with marked-up drawings and .installation diagram of Rheem RA Series Mechanical Units, prepared by American Test Lab of South Florida, Test Report No. 0323.01-15, dated 05/18/2015,signed and sealed by Stephen W.Warter,P.E. C. CALCULATIONS 1. Anchorage calculations prepared by Engineering Express,dated 11/20/2015,signed and sealed by Frank L. Bennardo,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Statement letter of code conformance to the 5,'edition(2014)FBC issued by Engineering Express,dated 08/24/2015,signed and sealed by Frank L.Bennardo,P.E. 2. Statement letter of no financial interest issued by Engineering Express,dated 11/20/2015,signed and sealed by Frank L. Bennardo,P.E. 3. Distributor agreement dated 11/12/2015. . .. . . . . . . .. . . . . ... . 0.0 . . 000 . . . 0. . ... 00 .., 0 Carlos M.Utrera,P.E. • 0 0 . Product Control Examiner . .. .. . . . . . NOA No.15-0903.08 "' ' Expiration Date:February 25,2021 Approval Date:February 25,2016 ... . .E.1.60 . ... . . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . RAM RHEEM SALES COMPANY, INC. , ,,,, „ PE6548H9iNARDO,P.E WIND LOAD CERTIFICATION OF MECHANICAL UNIT CABINETRY AND STEEL/ALUMINUM TIE-DOWN CLIPS: AT GRADE MOUNTED APPLICAj30�`�dS ; *: .46 4 0.3132 0.75D° �s��F•.TATE x18-GMn A ASTM rnA653 PAINTED STEEL Z CABNETRY o� sum.ro&Bul Sim.TO Q0 nur OO ON OPP.FACT ON OPP.FAC:L' go** (, • Z A C 0.187" • • •••• a-1 0080• • G CONCRETE 0 •••••• • d •• •�rjj CONCRETE iSUPPORTING • of SUPPORTINGSTRUC URE BY 0.306° YO •••••• • O • °Q STRUCTURE BY � B OTHERS,TYP. D TYP CONTROL BOX . *000 • • V •• op g OTHERS,TYP. • • ••••• Lo O 1 MECHANICAL UNIT /-2-'N MECHANICAL UNIT 8.06 X11.0 •• gg 00° at 1 N.T.S. FRONT ISOMETRIC 1 N.T.S. BACK ISOMETRIC TIE-DOWN CLIP 1 ••:••j : ••• � •• THESE ISOMETRICS ARE INTENDED FOR •• •• •••• •• i DIAGRAMMATICAL PURPOSES ONLY,ALTERNATE RHEEM MIAMI TECH CLIP:14GA(0.07°)ASTM A653 •••••• • W UNITS LISTED HEREIN MAY VARY IN APPEARANCE • • • Fu=90 KSI STEEL(CUTD10)OR 0.080° W (4)-#10 INTERNAL POST 5052-H32 ALUMINUM(CUTDAIO),MIAMI • • • • •• • SMS PER ADJACENT TO TECH KIT#RRCUTDLK OR RRCUTDALKOLIVER • 6 •••• g CLIP,TYP. CONTROL BOX • • • - •let • • PANEL, •• TVP. (37.25°--- P© ggg � CLIP(B)\l i 4 NIT BASE "� NIT BASE �Q UNIT BASE ` ~' ANCHOR PER PAN PAN PAN SCHEDULE m LIPUD , N Bi 3000 PSI MIN E CONCRETE BY CLI A DIM.1 p gggp OTHERS,I(P. ® O&© O CONTROL .A CLIP OFFSET.DIMENSION SHALL_` _ _ _ _� BOX__ Qg OARE SIMCCUR ON BE TAKEN FROM THIS§SDE ONLY AND ODATUM FACE �!a 3 TIE-DOWNFACFS CLIPS 4 TIE-DOWN CLIP LAYOUT Cq�EF®BRWALDPE 1 N.T.S. ELEVATION 1 N.T.S. PLAN 15-2543GA A piweA lB. gym• BCAtBt N.T9 ANCHOR SCHEDULE: TIE-DOWN CLIP OFFSETS. APPLICABLE MODELS: Cfle. « 51'TAOeUNITS SUBSTRATE DESCRIPTION RA1642A,RA1648,RAISN,RP1360, DIM.1 4.50°MAX OFFSET FROM DATUM FACE RP1460,RP1648,RD1448,RP1660, 3B7 TT CONCRETE: (11.94•B CARBON STEELDISTANCE, 3N STRONG SPACING T AN MIN EMBED TO DIM 2 30.00°MIN OFFSET FROM DATUM FACE RD1460,RAIUA1748,RArUA1780, CONCRETE,3'MIN.EDGE DISTANCE,3'MtN.SPACING TO ANY AD)ACENTANCHOR. 30 THICK MIN, RANA2048,RANA2080,RPNP7748, 61' 3000 PSI MIN.) (1)-u4IN CAR80N STEEL POWERSMI.WEOCAPAC BOLT},2}•EMBED T CONCRETE,3• DIM.3 31.00°MN OFFSET FROM DATUM FACE RP/UPi780.RPNP2048.RPNP20B0, //J 4 QQ MIN.EDGE DISTANCE,3•MIN.SPACING TO ANY ADJACENT ANCHOR. DIM.4 13.00°MAX OFFSET FROM DATUM FACE 2 SUPPORTING CONCRETE SUBSTRATE DEPTH SHALL BE A MINIMUM 1.5x NCMOR EMNED. L� EITHER ANCHOR FROM THIS SCHEDULE MAY BE USED FOR INSTALLATION. MIAMI-DADS MIAMI-DADE COUNTY. ffsml PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida33175-2474 BOARD AND CODE ADMIMSTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.mlamlaaae.ao 1ec nomv Rheem Sales Company,Inc. 5600 Old Greenwood Rd. Fort Smith,AR 72917 SCOPE:This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Mechanical Unit Steel and Aluminum Tie-Down Clips for Grade and Rooftop Applications APPROVAL DOCUMENT:Drawing No. 15-2543GA,titled"Wind Load Certification of Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips:At Grade and Roof Mounted Applications",sheets 1 through 7 of 7,dated 05/14/2015,revised on 11/20/2015,prepared by Engineering Express,signed and sealed by Frank L.Bernardo,P.E.,bearing the Miami-Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None LABELING:Each unit shall bear a permanent label with the manufactur-ers name or logo,city,state, model/series,and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. ..• .•: : : .0. : : ..• INSPECTION: A copy of this entire NUA shall be V14vi4ecltcC#u%V by the manufacturer or its distributors and shall be available for inspection at the job site'at* rehg4st%f th4BOilft%Official. This NOA consists of this page 1 and evidence page E-1,as well as approval document mentioned above. The submitted documentation was revjewpo,,by Carllo%M.Utre ra,PE. . . . . .. . . . . .. . . . . . . . . . • • •• NOA No. 15-0903.08 Expiration Date:February 25,2021 1APPRO D +•� !4�1�4 ••• • ° Approval Date:February 2 Page 1 ••• 0 0 0 000 0 • Rlteem Sales Company.Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 15-2543GA,titled"Wind Load Certification of Mechanical Unit Cabinetry and Steel/Aluminum Tie-Down Clips: At Grade and Roof Mounted Applications",sheets 1 through 7 of 7,dated 05/14/2015,revised on 11/20/2015, prepared by Engineering Express,signed and sealed by Frank L.Bernardo,P.E. B. TESTS 1. Test report on Uniform Static Air Pressure Test per FBC, TAS 202-94 along with marked-up drawings and installation diagram of Rheem RA Series Mechanical Units, prepared by American Test Lab of South Florida, Test Report No. 0323.01-15, dated 05/18/2015, signed and sealed by Stephen W.Warter,P.E. C. CALCULATIONS 1. Anchorage calculations prepared by Engineering Express,dated 11/20/2015,signed and sealed by Frank L. Bennardo,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Statement letter of code conformance to the 5a`edition(2014)FBC issued by Engineering Express,dated 08/24/2015,signed and sealed by Frank L.Bernardo,P.E. 2. Statement letter of no financial interest issued by Engineering Express,dated 11/20/2015,signed and sealed by Frank L.Bernardo,P.E. 3. Distributor agreement dated 11/12/2015. 0 0 1 LI/20 16 • •+• •a 0#0 • • Carlos M.Utrera,P.E. ' ' • Product Control Examiner • •. . • .. • • • NOA No.15-0903.08 •' ' ' ' "' ' Expiration Date:February 25,2021 Approval Date:February 25,2016 ••• . • +F•-L•• • • ••• • • • ••• • •