Loading...
FW-16-2704 k Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-268350 Permit Number: FW-10-16-2704 Scheduled Inspection Date: October 21, 2016 Permit Type: Fence/Wall Inspector: - 3' 0Q-q_ PC ekcA Inspection Type: Final Owner: CLAVIJO, ANDRES Work Classification: Wood Fence Job Address: 18 NW 107 Street Miami Shores, FL 33168- Phone Number (786)251-7865 Parcel Number 1121360070020 Project: <NONE> Contractor: HOME OWNER Building Department Comments WOOD FENCE 6 HIGH VERTICAL Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed `o�`��p , Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. October 20, 2016 For Inspections please call: (305)762-4949 Page 12 of 27 `y�tge�s i� Miami Shores Village e�rr• �c 10050 N.E.2nd Avenue NW Miami Shores, FL 33138-0000 Phone: (305)795-2204 , ' Petmit .H; ,i a :. Expiration: 102f2017 Project Address Parcel Number Applicant 18 NW 107 Street 1121360070020 ANDRES CLAVIJO Miami Shores, FL 33168- Block: Lot: Owner Information Address Phone Cell S ANDRES CLAVIJO 18 NW 107 Street (786)251-7865 MIAMI SHORES FL 33168- 18 NW 107 Street MIAMI SHORES FL 33168- Contractor(s) Phone Cell Phone '"' Valuation: $ 1,800.00 HOME OWNER Total Sq Feet: 100 Approved: Available Inspections: Comments: Inspection Type: Date Approved: Final Date Denied: Foundation Type of Construction:Wood Fence Additional Info:WOOD FENCE 6 HIGH VERTICAL Review Planning Classification: Residential Scanning:3 Review Building Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $1.20 Invoice# FW-10-16-61554 DBPR Fee $2.00 10/04/2016 Credit Card $ 116.20 $0.00 DCA Fee $2.00 Education Surcharge $0.40 Permit Fee-Wire&Wood $100.00 Scanning Fee $9.00 Technology Fee $1.60 Total: $116.20 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL,WINDOWS,DOORS, ROOFING and SWIMMING POOL work. OWNERS AF D VIT: certify at foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction rri r , I thorize the above-named contractor to do the work stated. October 04, 2016 Authorized Signature: wner / Applicant / Contractor / Agent Date Building Department Copy October 04, 2016 1 Miami Shores Village RECEIVED Building Department SEP 3 01016 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 4—f Tel:(305)795-2204 Fax:(305)756-8972 J INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 2014 r BUILDING Master Permit No. -P W � (0 r Z�o(l PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL F-]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP Xn .1 1' 1 L CONTRACTOR ( ?? / Q DRAWINGS JOB ADDRESS:1C/ &J �� ( O 7 �1 j+�(/Qyv(1 TOR?S rL . J J I C1O City: Miami Shores County: Miami Dade Zip: 3314e Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name(Fee Simple Titleholder): C� ��S k Cl ( L� Phone#::z J Address: —3ri City: A la State: - Zip: 33t lnly Tenant/Lessee Name: ,� Phone#: Email: Q1)Ori ,� LY L1 �' maj-L CONTRACTOR:Company Name: Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: !o p k F Type of Work: ❑ Addition ❑ Alteration ❑ New / Repair/Replace ❑ Demolition Description of Work: Ise yq (�1 1�2Cti<f_(:!1L'L . Specify color of color thru tile: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address _ City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approv d a reinspection fee will be charged. Signature Signature WNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this dayofOC�6b'er 20 t 14Z) byday of 20 , by �x`QS c rnt C lioy, who is personally known to who is personally known to me or who has produced 1 iV`2tr _,{CAYIS14, as me or who has produced as identification and who did take an identification and who did take an oath. NOTARY UBLIC: NOTARY PUBLIC: Sign: Jl Sign: Print: Print: Seal: - Seal: •�aa�P�'•- YANADY PRIEfo MY COMMISSION N FF 214031 ;•;a; EXPIRES:March 25,2015 6Fq, Bonded Thin Notary Public Undenunters APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) r ,5H°Rz Fs p� Miami Shores Village �t Building Department 10050 N.E.2nd Avenue Miami Shores Florida 33138 ORLDA ' Tel: (305)795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: ( AaQ l DATE:)h ADDRESS: �� A� Off' J ` �l►(�•U S� �I L Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida,F.S 489.103(7).And I have read and understood the following disclosure statement,which entitles me to work as my own contractor;I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor.You have applied for a permit under an exception to the law.The exemption allows you,as the owner of your property,to act as your own contractor even though you do not have a license.You must supervise the construction yourself.You may build or improve a one-family or two-family residence.You may also build or improve a commercial building at a cost of$25,000.00 or less(The new form states 75,000).The building must be for your own use and occupancy.It may not be built for sale or lease.If you sell or lease a building you have built yourself within one year after the construction is complete,the law will presume that you built for sale or lease,which is a violation of this exemption.You may not hire an unlicensed person as a contractor.It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances.Any person working on your building who is not licensed must work under your supervision and must be employed by you,which means that you must deduct F.I.C.A and with-holdings tax and provide workers'compensation for that employee,all as prescribed by law.Your construction must comply with all applicable laws,ordinances,buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner-builder permit under an exemption from the law.The exemption specifies that I,as the owner of the property listed,may act as my own contractor with certain restrictions even though I do not have a license. ,, ,� Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that,as an owner builder,I am the responsible party of record on a permit.I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name.I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding.I may also build or improve a commercial building if the costs do not exceed $75,000.The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete,the law will presume that I built or substantially improved it for sale or lease,which violates the exemption. Initial 4� 5. 1 understand that,as the owner-builder,I must provide direct,onsite supervision of the construction. Initial 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence.It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner-builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner-builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner-builder and am aware of the limits of my insurance coverage for injuries to workers on my property. _/�A\}�1 Initial • V_ 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done.Any person working on my building who is not licensed must work under my direct supervision and must be employed by me,which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act(FICA)and must provide workers compensation for the employee.I understand that my failure to follow these may subject to serious financial risk. Initial 4111� 9. 1 agree that,as the party legally and financially responsible for this proposed Construction activity,I will abide by all applicable laws and requirement that govern owner-builders as well as employers.I also understand that the Construction must comply with all applicable laws,ordinances,building codes, and zoning regulations. Initial 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service,the United States Small Business Administration,and the Florida Department of Revenues.I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.htm] Initial- 11. nitial11. 1 am aware of,and consent to;an owner-builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: nW ( o .41-n31 M a), 1shi n Initial 12. 1 agree to notify Miami Shores Village immediately of any additions,deletions,or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public.If you contract with a person who does not have a license,the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court.It is also important for you to understand that,if an unlicensed contractor or employee of an individual or firm is injured while working on your property,you may be held liable for damages.If you obtain an owner-builder permit and wish to hire a licensed contractor,you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued,this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit.A copy of the property owner's driver license,the notarized signature of the property owner,or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this �P day of 10 , 20 By AYN6,0 OS'e OQV Q) who was personally known to me or who has Produced there Lice se or br vele Li 'k Ch - entification. YANADY PRIETO MY COMMISSION#FF 214031 a EXPIRES:March 25,2019 OW I E R VARY ''� p, Bonded Thru Notary Public Underwriters NW 110{h SI 'NF 1lotn s[ �. Proudly Serving NW`DBth St Ii. « the Florida Real Estate Community B NW 10611h St T m NW 105th S1 i - X�'4W'- NW 104thSt > �• for Over 20 Years ••: `�' Clap d'Aa"]16 Goo9te WWW.MELANDSERVICES.COM N, , 107th STREE 173 ASPHALT PAVEMENT Vffrun V IJ uu- I -_ — o I Fe s Good Side Out. The vertical 7face h ASPHALT su ortin members of a fence sDRIVEWAY 24 PARKWAY f�R gnte'I'Dr of the plot on which the fenand the finished side shall face t 28.00' lot cr any abutting right-of-way. 5'. 'CONC.- 'S.1 kVALK` 75:00�(P)04, 75.00'(M) F.1.P.1/2" mss. 3 �1 F.LP.1/2" B.C. til F./.P.112" qd, V I ences Good Side Out. The vertical horizontal TILE upporting members of a fent, s II face the 14.60 17.04'— Q c terior of the plot on whicl i the fent is located o U nd the finished side shell face tie adjoining N of LU 5 of or any abutting right of ay. 2 014.00' V I E Q ON A Q 8.20 �? ONE STORY LU ® r~; RESI /(DENCE 3' NC -J C� � N 1l 8 ®_ N f� () 21.60' 11.84' h Ib.bq � z J O r 0 foo( a� c� ELI1 h P.ATI.O C vi P LLJ c. . o I 14.75' S M 6.20 .64 Fences Good Side Out. he vertical and horizontal supporting members c t a fence shall face the ►� interior of the plot on lich the fence is located2, _ I` and the finished side hall face the adjoining 20.71' lot or any abutting righ-of-way. 22.58' 1 CONC. 0.00 10.00' 2 N q 11 r`S 0.07-- 03 U 0.39' F.1.A112" X p X 45.85'X X ooh P.112 15' ALLEYM > 75.00'(P)(M) 9' ASPHALT PAVEMENT N Ac(:eptea by: — — – - — - - Property Address: •• ••• • • • • •Ott We f. NO•NOTES • • • • • 18 N.W.107 Sheet • • •• • • • Miami Shires,FLOP;DA 3316£ • •• • • • ••• • SURVELNTA ERiTFTC:aq :I HET2E8�cF2rlr-v 1l,A7n 710N. 7HISC wavES ISA Dc • ,E.•LaAd SQrve in Inc. RIDRESE:RATION OF A.SIP. UKiER M'�DIRERICY+. 7Mi5 CCN�l1E5 WITH THE MINIMUM TEG�H�ICAI Y 9' STANDARDS.AS SET TTiE STA L'%nDA BOARD 0'PROFESSIONAL LAND SURVEYORS IN CHAarER 10665 SW 190th Street 53.17.FLORIDA ADM . TIVE E 7 TD 472.027,F_ORIDA STAMFS.11 Suite 3110 SIG!''D FOR TNF FIRM 0•0 •�• • 'ami,IX4315'j• ••' Pfiorje:t30;)74V-3319 EFRAt:i i Z nw.0 ds. •• • • • • ♦ M. • 57ATE OF FE A iE ,L�y V.A.M.Nc.6792 • •• • • FvX:t306 X69-x•490 NOT MAP IS NOTyVAL1D WW O A610%iHC TLXM MGGviu RAI SEAL Or A�u��SUR�rOOR W M- LB#:798 • MAPPER. -•, ••• • • • • ••• • • ••• • • • ••• • • Survey#:B-13674 Client File#: Page 1 of 2 Not valid without all pages PROPERTY UNE Surveyor's Legend STRUCTURE FND iOUND IRON PIPE / B.R. BEARING REFERENCE TEL. TELEPHONE FACILITIES CONC. BLOCK WALL PIN AS NOTED ON PUT - CENTRAL ANGLE OR DELTA U.P. UTILITY POLE -X-X- CHAIN-LINK FENCE OR WIRE FENCE L.B/ LICENSE / - BUSINESS R RADIUS OR RADIAL E.U.B- ELECTRIC UTILITY BOX --//-/i WOOD FENCE LSy LICENSE Y - SURVEYOR RAD. RADIAL TIE SEP. SEPTIC TANK IRON FENCE CALL CALCULATED POINT N.R. NON RADIAL D.F. DRAINFIELD EASEMENT SET SET PIN TYP, TYPICAL A/C A,R CONDITIONER -- CENTER LINE ♦ CONTROL POINr I.A. IRON ROD S/W SIDEWALK X= WOOD DECK CONCRETE MONUMENT I.P. IRON PIPE DWY DRIVEWAY '/���� BENCHMARK N&D NAIL & DISK SCR, SCREEN CONCRETE ELEV ELEVATION PK NAIL PARKER-KALON Nk, GAR GARAGE PJ. POINT OF TANGENCY D.M. DRILL MOLE ENOL. ENCLOSURE ASPHALT P.C. POINT OF CURVATURE � WELL N.T.S. NOT TO SCALE BRICK / TILE P.R.M. PERMANENT REFERENCE MONUMENT FIRE HYDRANT I.F. FINNISHED FLOOR P.C.C. POINT GF COMPOUND CURVATURE ® M.H. MANHOLE I,O,B_ TOP OF BANK WATER P.R.C. POINT OF REVERSE CURVATURE EDGE OF WATER O.H.L. OVERHEAD LINES E.O.W. - APPROXIMATE EDGE OF WATER P.O.B. POINT OF BEGINNING TX TRANSFORMER E,D,P EDGE OF PAVEMENT P.O.C. POINT OF COMMENCEMENT CATV CABLE TV RISER C,V,G, CONCRETE VALLEY GUTTER COVERED AREA P.C.P. PERMANENT CONTROL POINT W.M_ WATER METER B.S.L BUILDING SETBACK UNE TREE M FIELD MEASURED P/E POOL EQUIPMENT S,T,L. SURVEY TIE LINE j7 POWER POLE P PLATTED MEASUREMENT CONIC. CONCRETE SLAB q CENTER LINE FTJ CATCH BASIN D DEED ESMT EASEMENT R/W WIGHT-OF-WAY C.U.E. COUNTY UTILITY EASEMENT C .. CALCULATED D.E. DRAINAGE EASEMENT P.U.E. PUBLIC UTILITY EASEMENT LE./E.E. INGRESS / EGRESS EASEMENI L.M.E. LAKE DR LANDSCAPE MAINT. ESMT. LB.E. LANDSCAPE BUFFER EASEMENTC.Y.E. CANAL MAINTENANCE EASEMENT U.E. UTILITY EASEMENT R.O.E. ROOF OVERHANG EASEMENT LAE LIMITED ACCESS EASEMENTA.C, ANCHOR EASEMENT Property Address: General Notes: 1.)The Legal Description used to perform this survey was supplied by others. 18 N.W. 107 Street This survey does not determine or is not to imply ownership FLORIDA 33168 2.)This survey only shows above ground improvements. Miami Shores, Underground utilities,footings,or encroachments are not located on this survey map 3.)If there is a septic tank,well,or drain field on this survey, Flood Information: the location of such items was shown to us by others and the information was not verified. 4.)Examination of the abstract of title will have to be made to determine recorded instruments,if any,effect this prope Community Number: 120652 rty.The lands shown herein were not abstracted for easement or other recorded encumbrances not shown on the plat Panel Number: 12086CO302L 5.)wall ties are done to the face of the wall. 6.)Fence ownership is not determined. Suffix: L 7.)Bearings referenced to line noted B.R Date of Firm Index: 09/11/2009 8.)Dimensions shown are platted and measured unless otherwise shown. Flood Zone: X 9.)No identification found on property corners unless noted. 10.)Not valid unless sealed with the signing surveyors embossed seal. Base Flood Elevation: N/A 11.)Boundary survey means a drawing and/or graphic representation of the survey work performed in the field,could Date of Field Work: 01/13/2016 be drawn at a shown scale and/or not to scale Date of Completion: 01/14/2016 12•)Elevations if shown are based upon NGVD 1929 unless otherwise noted 13.)This is a BOUNDARY SURVEY unless otherwise noted. 14.)This survey is exclusive for the use of the parties to whom it is certified.The certifications do not extend to any un named parties. 15.)This survey shall not be used for construction/permitting purposes without written consent from the land surveyor who has signed and sealed this survey. Legal Description: Lot 2, of Block 206, of Dunnings Miami Shores No. 3, according to the plat thereof, as recorded in Plat Book 42, Page 33, of the public records of Miami-Dade County, FLORIDA Printing Instructions: Certified To: While viewing the survey in any PDF Reader, select the File Glenn H. Kaufhold and Andres J. Clavijo Drop-down and select"Print". Select a color printer, if Law Offices OF Elizabeth J. Hutson, P.A. available; or at least one with 8.5"x 14" (legal) paper. Old Republic National Title Insurance Company Select ALL for Print Range, and the#of copies you would Mortgage Research Center, LLC like to print out. its successors and/or assigns as their interest may appear. Under the "Page Scaling" please make sure you have selected "None". Please copy below for policy preparation purposes Do not check the "Auto-rotate and Center" box. only: This policy does not insure against loss or damage by reason of the following Check the "Choose Paper size by PDF" checkbox, then exceptions:Any rights,easements,interests,or claims which may exist by reason click OK to print. of,or reflected by,the following facts shown on the survey prepared by EFRAIN LOPEZ dated 01/14/2016 bearing Job#B-13674 : a. NO NOTES M.E. Land Surveying, Inc. 10665 SW 190th Street, Suite 3110 Miami, FL 33157 Phone: (305) 740-3319 •• Fax: (305)669-3190 •• •1-5144 788b • . ... . . . . .. . . ... . . . ... . • • . . . . . ... . . . « • • • • • • • • • Survey#:B-13674 Client File#: V •. • • ••• 0 Page i oPY11ot valid without all pages tMORES tNC.1932 �� �� Miamishores Village RomeBuilding Department I- 4'e—E 9°�� 10050 N.E.2nd Avenue �LOKIDA Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 WOOD FENCE DETAIL ❑ Shadow Box Fences Good Side Out. The vertical and horizontal 4 Vertical Picket supporting members of a fence shall face the ❑ Board on Board interior of the plot on which the fence is located and the finished side shall face the adjoining lot or any abutting right-of-way. Fences < = 6' high posts spaced at 4' on center maximum Fences < = 5' high posts spaced at 5' on center maximum Fences < = 4' high posts spaced at 6' on center maximum Fence must not exceed 6' in height lx pickets fastened with two corrosion resistant fasteners per connection 2x4 horizontal pressure treated wood members with two corrosion resistant fasteners per connection 71 .. ... . . . . . .. • 4x4 pressure treated . . • • • posts euecfca42'1nt •• • concrete fobiifig 1"v • • - diameter x 2'deep ALL wood must be pressi e trL4ed • • . . All fasteners must be-corros:oc r�sfs*gr • No less than two fasteners in any coL7') 1) Side Out. The vertical and horizontal••• ' ••• members of a fence shall face the: • : e plot on which the fence is locate• •• ished side shall face the adjoiningbutting right-of way.