Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-16-2429
" INSPEC7M SERVICE Asm ENGINEERING 4225 SW 71 Ave, Miami. FI 33155 Tel:786-398-9179 Fax:786-800-2627 a1 roofinspectionCaD-gmail.com LAB CERTIFICATION #141215.04 SITE SPECIFIC INFORMATION UPLIFT TEST®TAS#106 Roofing Contractor ESTRADA ROOFING Permit# RF9162429 Job Address 25 NW 108 ST,MIAMI SHORES,FL Owner's Name MARCOS VELASQUEZ Type of Tile SPANISH S Date Installed Approximate Roof Height 12' feet Roof Pitch 3/12 Type of Access to Roof LADDER Approximate Square Footage of Roof 23 ftp Required Testing Force 35 Lbs Date Tested 10/14/2016 Number of Tests 62 Testing Equipment F.G.E.100 Contact Name ROBERT Phone# LOCATION #OF TEST PASS #OF TEST FAIL Corner 7 Tests 7 Pass Test Fall Perimeter 16 Tests 16 Pass Test Fail Field 25 Tests 25 Pass Test Fail Ridge 14 Tests 14 Pass Test Fail TOTAL 62 Tests 62 Pass Test Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106,THIS ROOF ASSEMBLY NAS PASSED THE STATIC UPUFTQUALTTY CONTROLTEST.THISTAS 106 MT HAS BEEN PERFORM®IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY,WITH NO DEVIATIONS.THIS REPORT IS NOTGUARANTEED IN CASE OF CASE OF NATURAL DISASTERS.THIS REPORT IT IS NDTYAUD FOR INSURANCE CLAIMS. F F 'I 1 , • ',: .a I C. YENAN•;T.LEl'�A P.E.#67416 A-1 Engineering Inspection Services, Inc 4225 SW 71 Ave Miami, FL 33155 Tel: 305-662-3710 Fax: 786-800-2627 alroofins ecp tiongamail.com LAB CERTIFICATION# 16-0510.15 10/14/2016 PERMIT. #RF9162429 25 NW 108 ST,MIAMI SHORES,FL T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. 07/26/2016 To: City of Miami Shores 10050 N.E. 2nd AVE Miami Shores FL 33138 Re: Owner's Name MARCO VELASQLIEZ / Property Address 25 NW 108 ST Roofing Permit Number Ift Ae-19-7 Z7 Dear Building Official: I Daniel Gonzalez-Lauzan certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water barrier has been provided as required by the"Manual of Hurricane Mitigation Retrofits for Existing Site-Built Single Family Structures" adopted by the Florida Building Commis 'on by Rule 9B-3.047 F. Qualifying Agent Signature of Qualifying Agent Daniel Gonzalez-Lauzan Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to annd,,subscribed dbbefore me this day of 2o ,20 ) NOTARY PUBLIC y ANAILYN ESTRADA (SEAL) STATE OF FLORIDA Comm#FF079161 Personally known 9/7012090 or Produced Identification C:lDoamema and Settinpe rtcl\My DooumeaW tatisticsCnpha Mooting affidavit Compli-9 26 07Filleble.doo NOME OF COMMENCE�l1ENT CFN:20160522415 BOOK 30220 PAGE 4860 DATE:09/07/2016 02:50:33 PM A N"MAST BE POM O1 THEAB SITE A'T1iNIE OF RUTINSPECTION HARVEY RUVIN,CLERK OF COURT,MIA-DADE CTY PEWIT Ivo ' �X FOLIO No. ll-2136-011-0300 STATE OF FLORIDA: COUNTY OF MIAM143ADE: THE LMER.SK3NED hereby gives notice that tmpmements will be made to certain real property.and in wwdwm with Clmpter 713,Florida S%U tes,thefollowing information Is provided In Oft Not#oe of Commencement. 1.Legal description of property and stj mWaddrem. 25 NW 108 ST MIAM SHORES,FL 33168 2.Description of trnprovernent RE-ROOF 3.Owner(s)name and adchm- MARCO VELASQUEZ 25 NW 108 ST / MIAMI SHORES FL 33168 interest in property: OWNER Name and address of fee simple titleholder. 4.Contractor's name and address: BTRADA ROOFING 1738 SW 57 AVE;MIAMI,FL 33155 5.Surety:(Payment bond required by owner from contracW,It any) Name and addr+ ISI/® Amount of bond$ 6.Lender's narne and address~ WA 7.Persons wlH*the s1oft of FWda designated by Omer upon whom natiaes or other doramterrts may be served as provided by Semon 713.13M7.,Florida Name and address: NIA 8.In addition to himseff,Owners designates the following person(sr to recelve a oopy of the Lienor's Notice as provided In Section 713.13(1)(b),Florida Statutes. //�� Name and address. N/A 9.Explratlo of Cammenc ernerm(tile exon date Is 1 year frown the date of wording uniess a 7 W d is S FROM DATE OF RECORDING i Print s Name_ ( rC� �S�Ch°Z proper by DANIEL,G LAUZAN Sworn to and subscribed before me oris AQ day of 201W Address: 1738 SW 57 AVE Notary Public A MIAMI,FL 33155 PrintName My on expire, C=m#FF07818t VG" 4 SW 1/10/2018 Permi N6 RF-94"29, Miami Shores Village elTt#!h TBpof . �n 10050 N.E.2nd Avenue NW 1+Ilarlc,tlasi>Catf011.Ti(elFlat Miami Shores,FL 33138-0000wWt Status:APPROVED"': ,. Phone: (305)795-2204 LORIDA .tsl rsate 9/612016 Expiration: 03/05/2017 Project Address Parcel Number Applicant 25 NW 108 Street 1121360110300 Miami Shores, FL 33168-4310 Block: Lot: MARCO VELASQUEZ MAGNA VI Owner Information Address Phone Cell MARCO VELASQUEZ MAGNA VIERIA 25 NE 108 Street MIAMI SHORES FL 33168-4310 25 NE 108 Street MIAMI SHORES FL 33168-4310 Contractor(s) Phone Cell Phone Valuation: $ 15,500.00 ESTRADA ROOFING (786)385-3137 _... Total Sq Feet: 1937 Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF SLOPE ROOF WITH ROOF TILE Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Roof in Progress Renailing Affidavit Review Roof Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 CCF Invoice# RF-9-16-61169 $9.60 09/06/2016 Check#:5750 $817.86 $0.00 DBPR Fee $4.13 DCA Fee $4.13 Bond#:3204 Education Surcharge $3.20 Permit Fee-New Roof $275.00 Scanning Fee $9.00 Technology Fee $12.80 Total: $817.86 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that II work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,I authorize the above-na d contractor do a works to . September 06,2016 Authorized Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy September 06,2016 1 Miami Shores Village Building Department SEP 1 2016 I 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 L INSPECTION LINE PHONE NUMBER:(305)762-4949 S-11 FBC 20( BUILDING Master Permit No. C/ PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC Q ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING F-1 MECHANICAL PUBLIC WORKS [] CHANGE OF CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 25 NW 108 ST City: Miami Shores County: Miami Dade zip: 33168 Folio/Parcel#: 11-2136-011-0300 Is the Building Historically Designated:Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): MARCO VELASQUEZ Phone#:305-978-3417 Address: 25 NW 108 ST City: MIAMI SHORES State: FL Zip: 33168 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: ESTRADA ROOFING Phone#: (786)385-3137 Address: 1738 SW 57 AVE City: MIAMI State: FL Zip: 33155 Qualifier Name: DANIEL GONZALEZ-LAUZAN Phone#: 305-668-8800 State Certification or Registration#: CCC 1328913 Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$15,500 Square/Linear Footage of Work: Type of Work: El Addition El Alteration ❑ New Q Repair/Replace ❑ Demolition Description of Work: RE-ROOF SLOPE ROOF WITH ROOF TILE ��jv js�y `j ��-y ;le— Specify color of color thru tile: _ Submittal Fee$ Permit Fee$ � CCF$ CO/CC$ Scanning Fee$ r • QJ3 Radon Fee$ a DBPR$ 1.� Notary$ Technology Fee$ Training/Education Fee$ F-:> Double Fee$,�1� Structural Reviews$ Bond$ SM I TOTAL FEE NOW DUE$ A _ . (Revised02/24/2014) 0p L/� ° C-/ 4 Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. in the nce of such posted notice, the inspection will not be appr d an reins fee will be charged. Signature Signature GE CONTRACTOR The foregoing inst ment was acknowledged before me this The foregoing instrument was acknowledged before me this day of 20 1( J2 .by day of -PMQ14f& 20 �by I�cI��C®�-Q Il [D, ,w �s t �cnnaliv i� to r ona y know me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign Sign: lo ER� Pri P t: TRADA Seal: NOTARY PUBLIC Seal: ANAILYN ESTRADA STATE OF FLORIDA NOTARY PUBLIC • ��Coom,m#FF079161 STATE OF FLORIDA +�r •xxwwa *•�aswsrK+� * *x *+r* * rr * awsaaseeara*r*• a Com7��r1� mxe** *M** aaw 1/10/2018 APPROVED BY "1' Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) y0 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 «� 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 GONZALEZ-LAUZAN, DANIEL N ESTRADA ROOFING 1738 SW 57 AVE MIAMI FL 33155 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range STATE OF FLORIDA from architects to yacht brokers,from boxers to barbeque DEPARTMENT OF BUSINESS AND restaurants,and they keep Florida's economy strong. PROFESSIONAL REGULATION Every day we work to improve the way we do business in order CCC1328913 18SUED: ` 06/22/2016 to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more CERTIFIED ROOE<ING CONTRACTOR information about our divisions and the regulations that impact GONZALEZ LAUZAN,DANIEL,N you,subscribe to department newsletters and learn more about ESTRADA ROOFING the Department's initiatives. Our mission at the Department is:License Efficiently, Regulate Fairly.We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, IS CERTIFIED under the provisions of Ch.489 FS. and congratulations on your new license! Expiration date:AUG 31,2018 L1606220000739 DETACH HERE RICK SCOTT, GOVERNOR KEN LAWSON,SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD � � £ CCC1326913 � The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31,2018 GONZALEZ-LAUZAN, DA1t11 L N ESTRADA ROOFING 1738 SW 57 AVE MIAMI FL'33165 ft. . ISSUED: 06/2212016 DISPLAY AS REQUIRED BY LAW SEQ# L1606220000739 i OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMII.Y RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. 07/26/2016 To: City of Miami Shores 10050 N.E.2nd AVE Miami Shores FL 33138 Re: Owner's Name MARCO VELASQUEZ Property Address 25 NW 108 ST Roofing Permit Number Dear Building Official: I MARCO VELASQUEZ certify that I am not required to retrofit the roof to wall connections of my building because: ✓❑ The just valuation for the structure for purposes of ad valorem taxation in less than$300,000.00. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 (Si4na re o r MA 0 Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this 60, day of gi�t5"I- ,20_0_g � (SEAJQ ANAILYN ESTRADA NOTARY PUBLIC STATE OF FLORIDA Comm#FF079161 Personally known s Expires 1/10/2018 or Produced Identification When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. C:L .—Is ed 9 9.PW 1\My D--dAStetisdes[lmpha_PR-fiog Affidavit Camphe 9 26 07F&ble.d. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Th F1 Code 5th Edition(2014) d 3 S T1 V, PE nlUHurricane Zone Uniform Permit Application Form. Master Permit No. Section A(General Information) Process No Contractors Name ESTRADA ROOFING Job Address 25 NW 108 ST ROOF CATEGORY o 0 Prescriptive BUR-RAS 150 lo 0 Mechanically Fastened Tile Mortar/Adhesive Set Tiles s It hingi 0 Metal Panel/Shingles 0 Wood Shingles/Shakes ROOF TYPE Repair 0 Maintenance Reroofing 0 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) QSteep Sloped Roof AREA(SSF)1,937 Total(SF)1,937 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, dearly identify dimensions of elevated pressure zones and location of parapets. 14 j f j > 16 Fri G0 35 r n5 cr, M W o < 34 Y< C 00 0: 0 a 0 0 00 2 15000 ••• •00 18.0 00: 0 •: % 0 0 00 :0 0:0 0:0 : : 0 :0: FLORIDA BUILDING CODE—BUILDING,5th EDITION (ALL 00 0 0 9 ee oe 15.37 Copyright to,or licensed by,ICC(ALL RIG RESEIVED)Oaccess:it" za el Gontez-L�on Aug 27,2mll'.08'14 AM punawn to License Agreement.No furtherltillf.119KIIIII� reproductionsauthormd. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition(2014) High-Velocity Hurricane Zone Uniform Permit Application Form 1 1 Section D(Steep Sloped Roof System) 1 1 Roof System Manufacturer: CERAMICA VEREA 1 Notice of Acceptance Number. 15-1123.01 1 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): 1 P1: 39.1 P1: 68.1 P1: 100.7 1 1 LARGE PAS 35 GRAMS 1 1 Deck Type: 5/8" PLYWOOD 1 -- 1 Type Underiayment: 30# ASTM D226 FELT l 1 [Roof 3 2 Insulation: E:::7 N/A 1 Fire Barrier: N/A 1 1 Ridge Ventilation? 1 Fastener Type&Spacing: 1.25 RS Nails 6" laps 12" field , 1 N/A ` -- - - ------ 1 ------------ - Adhesive Type: SELF ADHERED 1 1 Type Cap Sheet: BORAL TILE LINDERLAYMENT 1 \ 1 Mean Roof Height: 13' \\ Roof Covering: SPANISH S CLAY TILE 1 Type&Size Drip 3"0"26ga_galy. 1 \I Edge: 1 1 J1 .. ... . . . . . .. . .. . . . . ... . • . e .. ... .. . . . .. . ••• ••• . •e . . . . . . . .. . . .. . . . . . . . . . . . .. .. 000 see see ... . . . . ... . . . . .. . . . . . . . . . . FLORIDA BUILDING CODE—BUILDING,5th EDMOIJa91,90 • ••• •:• :• •: 15.39 jj,jjjrjj ` ' ' 1 ' Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Daniel Gonzalez-lmmn on Aug 27,lois 11:08:14 AM pmsoant to License Agre enL No fibber reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition(2014) 1 1 High-Velocity Hurricane Zone Uniform Permit Application Form. 1 1 1 Section E(Tile Calculations) 1 For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from M,. If the M,values are greater than or equal to the Mr values,for each area of the roof,then the file attachment method is acceptable. 1 1 Method 1 "Moment Based Tile Calculations Per RAS 127" 1 (Pi:39.1 x x.33 =12.90)-Mg:5.56=Mr, 7.34 Product Approval M, 48.45 1 (P2:68.1 xX .33 =22.47)-Mg:5.56=Miz 16.91 Product Approval Mf 48.45 1 (P3100.7xX.33 =33.23)-Mg:5.56=Mr327.67 Product Approval M, 48.45 1 Method 2"Simplified Tile Calculations Per Table Below" 1 Required Moment of Resistance(Mr)From Table Below Product Approval K 1 Mr required Moment Resistance* 1 Mean Roof Height 1 Roof Slope 15' 20' 25' 30' 40' 1 2:12 34.4 36.5 38.2 39.7 42.2 1 3:12 32.2 34.4 36.0 37.4 39.8 1 4:12 30.4 32.2 33.8 35.1 37.3 1 5:12 28.4 30.1 31.6 32.8 34.9 1 6:12 26.4 28.0 29.4 30.5 32.4 1 7:12 24.4 25.9 27.1 28.2 30.0 1 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and 1 Appeals. 1 For Uplift based file systems use Method 3.Compared the values for F'with the values for Fr. If the F'values are greater than or 1 equal to the Fr values,for each area of the roof,then the file attachment method is acceptable. 1 Method 3"Uplift Based Tile Calculations Per RAS 127" 1 (P1: x L = x w:_ )-W: x cos 0 =Fr, Product Approval F' 1 (P2: x L = x w:=---)-W: x cos 0 =F, Product Approval F 1 (P3: x L = x w:__)-W: x cos 0 =Fr, Product Approval F 1 1 Where to Obtain Information 1 Description Symbol Where to find 1 Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 1 Mean Roof Height H Job Site 1 Roof Slope 0 Job Site 1 Aerodynamic Multiplier A. Product Approval 1 Restoring Moment due to Gravity Mg Product Approval 1 Attachment Resistance , . . : . Ploduct Approval 1 Required Moment Resistance M'g• •; : : ; •Qp"plateg 1 Minimum Attachment Resistance rPMuct Vpprovai 1 Required Uplift Resistance Fr Calculated 1 Average Tile Weight . IJV .PrOdM A46Dval 1 Tile Dimensions L =lengo j. ,MdtFC• ; •Pfolucl Appjoval 1 All calculations must be submitted to the building official at a lime of permit appli tion. 1 . . . . . . . . . . 15.40 • • :• •: •FNORIlD14 JVIILl711VG CODE-BUILDING,5th EDITION(2014) LL Copyright to,or Ncensed by,ICC(ARIGHTS RESERVED);accesed Daniel Gonnrrj''e Tu-n on Aug 27,zoi s m08-14 AM pursuant to License Agreement.No further reprod....authorized. MIAMI-DADE • "Delivering Excellence Every Day" NIIAW-DARE COUNTY REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane 5ne)]are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance,that are not part of a zoning code, should be addressed Pof the agreement between the owner and the contractor. 2.Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Bu' g Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring unitsi.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or ow should notify the occupants of adjacent units of roofing work to be performed. 77 Ped 4.Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be iefrom below. The owner may wish to maintain the architectural appearance; therefore,roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of m ' taLL ming this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond(accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roof g system is removed. Ponding conditions should be corrected. 01-1 6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers(wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance wi the requirements of. Chapter 15 and 16 herein and the Florida Building Code,Plumbing. 7.Ventilation: Most roof structures should have some ability to vent natural airflow through the rote 'or of the structural assembly(the building rtseft 'fie 9xist ng amount of attic ventilation shall not be reduced. %:. . . . . . . . r ... .. . . .. Owner's/Agent's Signature: 0 ate: / ✓�� / rte' Contractor's Signature: •• I:0mit Number: Property Address: 25 NW 108 ST _T J • . . . . . . . . . . . . .. .. . . .. .. ... 0 . . % . . . MIAMI-DADE COUNTY r PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) MM .miamidade.eov/Rrra Ceramica Verea Lanza S/N 15685 Mesia(Corui;ia)Spain SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). _. This NOA shall not be valid after the expiration date stated below.The Miami Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Clay Spanish"S"Roof Tile with Verea System LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages I through 5. go ,.. . . . . The submitted documentation was reviewed by Alex Tides..: . . . . . . ... . . .. ... . .. . . . . . . . .. . . . .. .. . . . . . . NOA No.: 15-1123.01 MIAMbDADE COUNTY '• ' ' • • • Expiration Date:03/13/18 Approval Date:12/10/15 ... ... Page 1 of 5 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . ROOFING ASSEMBLY APPROVAL Category Roofing Sub Category: Roofing Tiles Material: Clay 1. SCOPE This approves a roofing system using Clay Spanish "S" Roof Tile manufactured by Ceramica Verea, S.A. in La Coruna, Spain and is distributed by Ceramica Verea, USA, as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Descrintion Clay Spanish"S"Roof Tile L= 19.5" ASTM C1167 High profile clay roof tile. For direct W= 11.3" deck,adhesive set applications. Thickness: 0.44" Trim Pieces Length:varies ASTM C 1167 Accessory trim,clay roof pieces for Width:varies use at hips,rakes,ridges and valley varying thickness terminations manufactured for each tile profile. Verea Hurricane Clip 2.95"x 0.47'x 0.09"diam. (Optional)stainless steel clip. 2.55"x 0.47'x 0.09"diam. 2.16"x 0.47'x 0.09"diam. 2.1 MANUFACTURING LOCATION 2.1.1. Mesia(La Conuna)Espana 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date American Test Lab of South Florida RT0706.01-11 ASTM C 1167 07/19/11 RT0311.01-14 TAS 101 03/18/14 IBA Consultants,Inc. 4709-3 TAS 101 12/21/07 PRI Construction Materials CVER-013-02-01 TAS 101 12/30/13 Technologies CVER-014-02-01 TAS 102 03/11/14 CVER-015-02-01 TAS 100 04/07/14 3. LIMITATIONS: •• ••• •• 3.1 Fire classification is not part of this acc8pW4-• ••• • 3.2 For mortar or adhesive set tile applicaf ons,'a'static IA uplift test in accordance with TAS 106 may required,refer to applicable building code. . ... ... . .. . . . . . . . .. . . .. . . . . . . . . . . .•• :• :• •.• �.� NOANo.: 15-1123.01 Muar�i°A°;coin Expiration Date:03/13/18 • • • • Approval Date: 12/10/15 • • • • Page 2 of 5 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix`A'. Such testing shall be submitted to the Building and Neighborhood Compliance Department—Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Clay Spanish"S"Tile and its components may also be installed with"Verea System"underlayment system in strict compliance with current NOA. Clay Spanish"S"Tile shall be installed as per applicable sections of Roofing Application Standard RAS-120. 4.2 Data For Attachment Calculations. Table 1: Average Weight(W)and Dimensions(I x w) Tile Profile Weight W(lbf) Length-1(ft) Width-w(ft) Clay Spanish "S"Tile/Verea 8.3 1.625 0.942 System Table 2: Aerodynamic Multipliers -A(ft3) Tile A(ft3) A(ft3) Profile Batten Application Direct Deck Application Clay Spanish "S" Tile/Verea N/A 0.33 System Table 3: Restoring Moments due to Gravity-Mg (ft-lbf) Tile 2":12" 3"•12" 4"•12" 5"•12" 6"12" 7"•12" Profile or Greater Clay Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Spanish "S" 5.63 5.56 5.47 5.35 5.21 5.06 Tile/Verea System Table 6: Attachment Resistance Expressed as a Moment-K(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Clay Spanish 3MTm 2-Component Foam Roof Tile Adhesive AH-160 48.45? "S" Tile/ Verea System 1 Large paddy placement weight 35 grams of BAAT"2-Oor�po�enl Fpap Roof Tile Adhesive AH-160. . .. . . . . ... . • ••• ••• • •• • • • • • • • •• • • •• • • • • • • • • • • 0*' ' ' NOA No.: 15-1123.01 MIAMI-DADE COUNTY Expiration Date:03/13/18 Approval Date: 12/10/15 ••• • • ••• Page 3of5 . . . . . • . . . . • .. •. . . . .. •• ... . . . ... . . 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". VE REA S PAU N E LABEL FOR CLAY SPANISH"S" ROOF TILE (LOCATED ON THE SIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. .. ... . . . . . .. . .. . . . . ... . • g! . .. ... ..• .• . . .. . ••• ... . •• . . . . . . . .. . . .. . . . . . . . . . . . ego . . ... .. .. . NOA No.: 15-1123.01 WMIAMMADECOUNTYM Expiration Date:03/13/18 ••• • Approval Date: 12/10/15 • • Page 4 of 5 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . PROFILE DRAWING 19.5" O 11.3" CLAY SPANISH S ROOF TILE d VEREA HURRICANE CLIP NOTE: USE OF CLIP IS OPTIONAL. REFER TO MANUFACTURERS PUBLISHED INSTRUCTIONS FOR .iWSMATIONIMtAk.•• . .. . . . . ... . END OF THIS AeCAP fAXft . ... ..• . .• . ... . . :. . . . :00 : . .00 i0 ' '.• 000 '.' NOA No.: 15-1123.01 MIAMI-DADE COUNTY Expiration Date:03/13/18 �Fmjmerjwl Approval Date: 12/10/15 0" Page 5 of 5 . . . . V: . . . . . .. .. 00 . .. .. ... . . . ... . . GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials.The documentation submitted has been reviewed by Miami-Dade County Product Control Section. G1-SOLAR REFLECTANCE AND THERMAL EMMITANCE Component Name Initial Aged Initial Aged Solar Reflectance Reflectance Reflectance Emmitance Emmitance Index(SRI) 1. Clay Spanish"S" 0.39 Pending 0.83 Pending 41 Tile .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... ... . .. . . . . . . . .. . . .. . . . . . . . . . . ..• s0 :0 •.' •.• •.• NOA No.: 15-1123.01 MMI-DADe Cour Expiration Date:03/13/18 ••• •• Approval Date: 12/10/15 • • • Page 6 of 5 . . . . . . . . . . . .. .. 00 . .. •. ... . . . ... . . MIAMMDADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing LLC. 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be prov''ded t'p �er•by We manufacturer or its distributors and shall be available for inspection at the job site at th8 regd*tbfWt$u464ig©ricial. •• ••• of • • • •• This revises NOA#12-1219.01 and consists of pages 1 through 4. The submitted documentation was reviewed by j vr-.-Coll"pR.A. *00 •.• . . . . . . .. . . .. . . . . . . . . . . • . . • • NOA No.: 13-1113.05 �DE cD L Expiration Date: 07/31/17 ••• •••• • • Approval Date: 03/13/14 • • • • • Page 1 of 4 . •• •• 00 . •• .. ... . . . ... . . ROOFING COMPONENT APPROVAL Category: Roofing Sub-Cateeory: Underlayment Material: SSS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36"x 36' rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood,NH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. R14610 Follow up Service 03/28/02 IRT-Arcon,Inc. 02-012 TAS 103 02/28/02 PRI Asphalt Technologies,Inc. NEI-006-02-01 TAS 103 04/01/02 PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114(H) 07/30/02 PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM G 155 08/08/07 Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM G 155 05/01/08 NEI-076-02-01 TAS 103/ASTM D4798 02/14/11 NEI-034-02-02 ASTM D 1970 01/29/13 .. ... . . . . . .. . .. . . . . ... . • ••• ••• • •• • • • • • • • •• • • •• • • • • • • • • • • • •• •• • • • • • • •• • • • • • NOA No.: 13-1113.05 MIAMI•DADE COUNTY Expiration Date: 07/31/17 Lus ••• • ••• • • Approval Date: 03/13/14 • • • • • • Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the laps and two staggered rows 12" o.c.the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6"o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened Roof Tile, Metal Roofing,Wood Shake&Shingles,and Asphaltic Shingle assemblies. •• to: • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• • ••• ••• • •• • • • • • • • •• • • •• • • • • • • • • • • • •• •• • • • • • • •• • • t • • NOA No.: 13-1113.05 MIAMI•DADE COUNTY Expiration Date: 07/31/17 ••• • • • • ••• • • Approval Date: 03/13/14 • • . • • • • t Page 3 of 4 • •• •• • • • •• •• ••• • • • ••• • s LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth,clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment;loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment,and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility,and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below IUMMF ECOUNTY •• • •• • • • • ••• • END OF sf M*S ACCEPTANCE . ••• ••• . •• . . • . • • . .. . . . . . . :Go : : . .. .. . . . . . . •• • NOA No.: 13-1113.05 MIAMt•DADECOUNTY Expiration Date: 07/31/17 • • • • • • • • Approval Date: 03/13/14 i i • i i•i i i • i Page 4 of 4 • •• •• • • • •• •• MIAMI-DAD>E:! j MIAMI-DADE COUNTI' f — PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami.Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) Boral Roofing LLC. 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.if this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building(btle6. including the High Velocity Hurricane Zone of the Florida Building Code. 600 ' .. . . 99 DESCRIPTION: BORAL TileSeal 0000.. 0000.. 0000 0000 . . LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,e4y,0te and fiaUq*ing ..... statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein....... Soo* 06:966 9 . 9 . .. .. .. . 0000.0 RENEWAL of this NOA shall be considered after a renewal application has been filed and VIM4V been no change •6 in the applicable building code negatively affecting the performance of this product. :000:0 "'660 TERMINATION of this NOA will occur after the expiration date or if there has been a revision o;change ir►the 6 materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#12-1219.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Juan E.Collao,R.A. NOA No.: 13-1113.05 MIAMI RADE COUNTY ' Expiration Date: 07/31/17 APPROVED Approval Date: 03/13/14 __- Page 1 of 4 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36"x 36' rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood,NH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. R14610 Follow up Service •03128/02 IRT-Arcon,Inc. 02-012 TAS 103 ••• ••OY18/02 .... �• PRI Asphalt Technologies,Inc. NEI-006-02-01 TAS 103 . ,,••, .,.0***91/02 • • PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114(H) •.. •W130102 :• ••: PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM 0-j��.• •.•-j0.8-(68/07 ••••• Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM Cs 155.. ..W01/08 .....• NEI-076-02-01 TAS 103/ASTM D4796�..� '•.42/:4/1 l ...... NEI-034-02-02 ASTM D 1970 •••••• 6029/13 • . . . . ...... . 00 090:00 0 0 00 0 NOA No.: 13-1113.05 MIAM4DADE COUNTY Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 1`112" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626 with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c.at the laps and two staggered rows 12"o.c.the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6"o.c.at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened RoQUile, Metal Roofing,Wood Shake&Shingles,and Asphaltic Shingle asserabli esR •••• ••..�. ...... .... ....% .... .... . . .... .... ..... ...... .... ..... .. .. .. . ...... . . . . ...... .. • •000 . . NOA No.: 13-1113.05 h�wMinaoecouN7P Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth,clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any lose decking p Ea�e1st.Sive eZ the deck thoroughly to remove any dust and debris prior to application. • ' IL. When applying the membrane in the valley. start at the low point and work to the high po'�,•nolling*tk:.membrar4%..:. from the center outward in both directions. For ridge applications, center the membratedro roll fromethe cent]r...� outward in both directions. 0 0* 0 0•0*6 12. Roll or broom the entire membrane surface so as to have 100%contact with the surfac s eci�I ention io • *tip p i.sl� ..... overlap areas. ..0..0 0 .. . ...... 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assem%lyeMent Product Control .� Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This t get Ciece stllI be press;d...� in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeatit9de4ayment shall be applied over the underlayment,and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below JAPP MwMFnuwE couNrY OVED1 END OF THIS ACCEPTANCE NOA No.: 13-1113.05 MIAMFDADECOUNTY Expiration Date: 07/31/17 JAP_PROVED1 Approval Date: 03/13/14 Page 4 of 4