Loading...
WS-15-1419 (2) Permit NO. WS-6-15-1419 �s+±OMiami Shores Village Permit Type:Windows/Shutters 10050 N.E.2nd Avenue NW Perm 't ' p rlc Classification:Window/Door Re lacem Miami Shores,FL 33138-0000 Permit Status:APPROVED Phone: (305)795-2204 Issue Date:6/19/2015 Expiration: 1 211 6/2 0 1 5 Project Address Parcel Number Applicant 29 NW 94 Street 1131010340140 Miami Shores, FL 33150- Block: Lot: STEPHEN HARPER ODALYS AC Owner Information Address Phone Cell STEPHEN HARPER ODALYS ACOSTA 28 NW 94 Street MIAMI SHORES FL 33150-2237 Contractor(s) Phone Cell Phone Valuation: $ 13,762.73 FOWLER ENGINEERING CONTRACTC (954)964-8244 (561)309-2637 Total Scl Feet: 320 Type of Work:REPAIR AND REPLACE IMPACT WINDOWS( Available Inspections: No of Openings:18 Inspection Type: Additional Info: Window Door Attachment Classification:Residential Final Scanning:4 Review Building Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $8.40 Invoice# WS-6-15-55924 DBPR Fee $4.20 06/10/2015 Check#:4363 $50.00 $272.80 DCA Fee $4.20 Education Surcharge $2.80 06/19/2015 Check#:4397 $272.80 $0.00 Permit Fee $280.00 Scanning Fee $12.00 Technology Fee $11.20 Total: $322.80 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFI VI I certify 11 the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an o g. Futherm authorize the above-named contractor to do the work stated. June 19, 2015 Auth ized gnature:Ow / Applicant / Contractor / Agent Date Building Department Copy June 19,2015 1 10. 9. 1 EA HR 37 X27 1EAHR37X27 • ••• NOA#14-0317.01 NOA#14-0317.01 •• •• • • • •• •• • • • • • • • • • • • REAR +48.6/-65.1 +48.6/-65.1 ` • • • ••• • • • 6.94 SQ FT ray li Ln • • • • • • • 6.94 SO FT O J N LL ® 8 • •• • • • ••• 12. 1 EACA37X27 � • • • •• • • •• • 1 EA HR 97 X 62 XOX BD RMNOA#13-0206.07 • • •• • • • • • • •• NOA#14-0317.01 (n Q • • • • • • • • • +48.61-52.7 "�9r • • • • • • • • • • +48.6/-52.7 6.94 SO FT ltFhyi,/'{ 41.76 SQ FT Q >4 13. Q M 7. Z •NOAV1103.06 I*EAOSH 4J7 X 3j •• •• 1EAHR,37X27 S • ••• • • • 48, 11, NOA#14-0317.01 1y►48 /-:2. •• NO $FD 34 X 81#12-0402.03 1 EA HR 97 X 62 XOX BATH V!i •i0.0 SQFf • • •• •• NOA#14-0317.01 7 6.94 SO FT 19.13 SQFT1 +48.61-52.7 DIN RM 41.76 SQ FT UJ M 1 Miami Shores Village CO N O 14. APPROVED BY VATE � t EA SH 37 X 39 6 NOA#14-0317.02 `p i�pq �g 1 EA CA 38 X 51 ZONING DEPT NOA#13-0206.07 +48.61-52.7 {.. BDRM +gg.61-52.7 y 10.02 SQ FT 1 P9 V1 KITCHEN BLDG DEPT (� (J/ 13.46 SQ FT u y )MM i�- w .6J SUR I MT TO COMPI IANME WITH ALL FFDFRAL Q �O EXISTING SFR E I ATF AND cit Ire ry RUI FS AND RF GUI AMNS 5 H - BATH I EA SH 38 X 39 16 MRH NOA#14-0317,02 u w WINDOW REPLACEMENT ONLY/NO SIZE CHANGE +48.6/-527 O 10.29 SO FT 15 W 1 EA HR 47 X 35 LIV RM B u) NOA#14-0317.01 41 EA SH 38 X 39 +48.6/-52.7 NOA#14-0317.02 Q ,� 11.42 SO FT E� +48.6/-52.7 DEN ® 10.29 SO FT W C-4 ®_ U) A. trsl a = 1 EA STEEL DOOR 39 X 82 W FL#11136.2 +48.6/-52.7 22.21 SQ FT4 3. 16. 1, 1 EASH38X51 Z 1 EA HR 74 X 38 1 EA HR 111 X63 XOX NOA#14-0317.02 NOA#14-0317.01 NOA#14-0317.01 B N +48.6/-52.7 +48.61-52.7 +48.6/-52.7 13.46 SQ FT 19.53 SQ FT 48.56 SQ FT to � 2. �+ y tEAHR58X51 ice. Ai NOA#14-0317.01 FRONT +48.6/-52.7 0 Q 20.54 SQ FT ASCE 7-10 Design Wind Loads REGIONAL WIND LOAD CHART SeC SOUTH FLORIDA EDITION- .•1 4II Components &Cladding _ • 600 • • P ASD Load Combination Coefficient: 0.6 Kat= 1.0 "°�``'" 'rl'%• :V4irid Presse,tires[psf]For ase with Allowable Stress Design Enclosed Bldg: GCp1=±0.18 Kd= 0.85 Droward,Palm Beach Broward,Palm Beach(Coast) Miami-Dade Miami-Dade(Coast) Florida Keys(Coast) Wind Speed: 170 mph VYiild gjegd4l7g rVPJ1•; ::•Wind Speed: 175 mph Wind Speed: 175 mph Wind Speed: 180 mph Exposure Category'C' Ei b4!i'e Cath o"s .D' :• . :Exposure Category'C' Exposure Category'D' Exposure Category'D' Mean Mean Mean Mean Mean All Triburary Areas All Triburary Areas All Triburary Areas All Triburary Areas All Triburary Areas Roof Roof Roof Roof Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 • • Height Interior Comer Height • Tnt•to • • C n •Height interior Corner Height interior Corner Heigh Interior Corner -m-to: + - + - up to: +• •r lbol 0 up to: + - + - up to: + - + - 15 ft +37.8-41.0 +374-75 fz_ 0 -(A •-- .1 43.4 +40.1 .6 -15 +48.rly-52.7 -+48.-6-6 . - +31.4 -6i8?9 20 ft +40.2-43.6 +40.2-53.8 20 ft +48.2-52.3 +48.2-64.6 20 ft +42.6-46.2 +42.6-57.0 20 ft +51.1-55.4 +51.1-68.4 20 ft +54.1-58.6 +54.1-72.4 25 ft +42.1-45.7 +42.1-56.4 25 ft +50.1-54.4 +50.1-67.1 25 ft +44.6-48.4 +44.6-59.7 25 ft +53.1-57.6 +53.1-71.1 25 ft +56.2-61.0 +56.2-75.3 30 ft +43.7-47.4 +43.7-58.6 30 ft +51.7-56.1 +51.7-69.3 30 ft +46.3-50.3 +46.3-62.1 30 ft +54.8-59.5 +54.8-73.4 30 ft +58.0-62.9 +58.0-77.7 35 ft +45.2-49.0 +45.2-60.5 35 ft +53.2-57.7 +53.2-71.2 35 ft +47.9-51.9 +47.9-64.1 35 ft +56.3-61.1 +56.3-75.4 35 ft +59.6-64.6 +59.6-79.8 40 ft +46.5-50.4 +46.5-62.2 40 ft +54.4-59.0 +54.4-72.8 40 ft +49.2-53.4 +49.2-65.9 40 ft +57.6-62.5 +57.6-77.2 40 ft +61.0-66.2 +61.0-81.7 45 ft +47.6-51.7 +47.6-63.8 45 ft +55.5-60.2 +55.5-74.3 45 ft +50.5-54.8 +50.5-67.6 45 ft +58.8-63.8 +58.8-78.8 45 ft +62.3-67.5 +62.3-83.4 50 ft +48.7-52.8 +48.7-65.2 50 ft +56.6-61.3 +56.6-75.7 50 ft +51.6-56.0 +51.6-69.1 50 ft +59.9 -65.0 +59.9-80.2 50 ft +63.4-68.8 +63.4-84.9 55 ft +49.7-53.9 +49.7-66.5 55 ft +57.5-62.4 +57.5-77.0 55 ft +52.7-57.1 +52.7-70.5 Oft +60.9-66.1 +60.9-81.6 Oft +64.5-69.9 +64.5-86.3 60 ft +50.6-54.9 +50.6-67.8 60 ft +58.4-63.3 +58.4-78.2 60 ft +53.6-58.2 +53.6-71.8 60 ft +61.9-67.1 +61.9-82.8 60 ft +65.4-71.0 +65.4-87.6 70 ft +47.8-47.8 +47.8-87.7 70 ft +54.9-54.9 +54.9 1-100.6 70 ft +50.7-50.7 +50.7-92.9 70 ft +58.2-58.2 +58.2-106.6 70 ft +61.5-61.5 +61.5-112.8 80 ft +49.2 -49.2 +49.2-90.2 80 ft +56.2-56.2 +56.2-103.0 80 ft +52.1-52.1 +52.1-95.6 80 ft +59.5-59.5 +59.5-109.1 80 ft +63.0-63.0 +63.0-115.4 90 ft +50.4-50.4 +50.4-92.5 90 ft +57.3-57.3 +57.3-105.1 90 ft +53.5 -53.5 +53.5-98.0 90 ft +60.8-60.8 +60.8-111.4 90 ft +64.3-64.3 +64.3-117.8 100 ft +51.6-51.6 +51.6-94.6 100 ft +58.4-58.4 +58.4-107.1 100 ft +54.7-54.7 +54.7-100.2 100 ft +61.9-61.9 +61.9-113.4 100 ft +65.5 -65.5 +65.5-120.0 120 ft +53.6-53.6 +53.6-98.3 120 ft +60.3-60.3 +60.3-110.5 120 ft +56.8-56.8 +56.8-104.1 120 ft +63.9-63.9 +63.9-117.1 120 ft +67.61-67.6 +67.6-123.9 140 ft +55.4-55.4 +55.4-101.5 140 ft +61.9-61.9 +61.9-113.5 140 ft +58.7-58.7 +58.7-107.6 140 ft +65.6-65.6 +65.61-120.3 140 ft +69.4-69.4 +69.4-127.2 160 ft +56.9-56.9 +56.9-104.4 160 ft +63.4-63.4 +63.4-116.2 160 ft +60.3-60.3 +60.3 -110.6 160 ft +67.1-67.1 +67.1-123.1 160 ft +71.0-71.0 +71.0-130.2 180 ft +58.4-58.4 +58.4-107.0 180 ft +64.7-64.7 +64.7-118.6 180 ft +61.9-61.9 +61.9-113.4 180 ft +68.5-68.5 +68.5-125.7 180 ft +72.5 -72.5 +72.5 -132.9 200 ft +59.7-59.7 +59.7-109.4200Ift +65.9 1-65.9 +65.9-120.8 200 ft +63.2-63.2 +63.2 -115.9 200 ft +69.8-69.8 +69.8-128.0 200 ft +73.9-73.9 +73.9-135.4 In •Design conforms to the 2010 Florida Building Code. •Wind Speeds noted above are ultimate design wind •Wind pressures are applicable to all building floors. a a Valid only with engineer's •Tabulated design wind loads are based on ASCE 7-10 speeds(3-second gust). •Tabulated wind pressures are valid for all roof slopes,no specifications for components and cladding based on design •Cities and/or counties are listed only as a general guide, reduction for roof slope 510°has been considered. JE5 i signature raised seal criteria as noted herein. based on Risk Category 11 buildings.Verify applicable wind •Tributary Area noted In table(effective wind area)is Zorn permit,applicability of speed and exposure category with kcal building equal to the minimum of[height x width]or(ht x ht/3]. •Where this document is used for po 4 i 5 Z04- � design criteria noted herein(Basic Wind Speed,Exposure department. Round down to values shown. 5 4 :5 Category,Risk Category,etc.)shall be verified by the ,us W&minus(-)signs signify pressures acting toward •Zones 4&5(°Interior°and°comer"zones,respectively) _ contractor&building official prior to construction. and away from the exterior component or cladding surface, areas shown to the right,where the dimension•a°Is the Eaaa Height rm"Y4 ®15 •This specification may be used In conjunction with respectively. minimum of 10%of the building's least horizontel Mean Roof Ht engineering under separate certification(by this engineer •Where"Mean(average)Roof Height'cannot be dimension or 40%of the mean roof height,but never less i or by others)using Allowable Stress Design(ASD). determined,peak roof height shall be used,except that than T-G'or 47.of the least horizontal dimension. Peak Height 1 Th r i st 13 In't Migile u1b E •Refer to the above-noted ASCE 7 standard for eave height shall be used for roof angle less than or equal •This specification Is valid only for use with structures NOT descriptions and definitions of all design criteria. to 10°.Round up to values shown located In the upper one-half of an Isolated hill,ridge or WALL ELEVATION WALL ELEVATION FL PE#67382 CA#29531 1200 N Federal Hwy,#200,Boca Raton,FL 33432 •Design Is based on structure classification as Enclosed Bldg: Copyright 02015 Easy Seals Document No.MRS