Loading...
REV-16-252 C-) Miami Shores Village JAN 2 9 2015 Building Department ,, 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 I Ll BUILDING Master Permit No.ELC-10-14-2333 PERMIT APPLICATION sub Permit No. V I 1(to—2sz, BUILDING ro-1 ELECTRIC ❑ ROOFING ❑ REVISION EXTENSION KRENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd Avenue- Library Fire Alarm City: Miami Shores County: Miami Dade Zip: 33161 Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction/Type: Flood Zone: BFE: JFFFFE: OWNER:Name(Fee Simple Titleholder): / oirr v +(/ �/%� Phone#: Address: 11300 /V 2nd A6,ujf City: State: Zip: U411- 1 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Sentry Security, Inc. Phone#: 954-452-8500 Address: 10001 NW 50th Street#111 Cm,. Sunrise State: FL Zip: 33351 Qualifier Name: Evan Katz Phone#: 954-452-8500 State Certification or Registration#: EF0001190 Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace E] Demolition Description of Work: Q-.C��si C`n sn 1 � C»1 ��1rGltltr l perrop vi re . Specify color of color thru tile: Submittal Fee$ :::: Permit Fee$ CCF$ CO/CC$ Scanning Fee$ 2) 100 Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ � (Revised02/24/2014) "� r Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address city State Zip Application Is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500,the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature e2� ,.GINNER or AGENT CONTRACTOR - The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day �/Y- 20 ,by t,*4'-'day of 1�5 by 4 sonall known to l�1Cir1 ��Z-`who is personally known to me or who has produced J& 1 pAl)IF /kas me or who has produced as identification and who di#akelYOly� ,: identification and who did take an oath. Offen NOf31C Pt7611C:'i •� = NOTARY PUBLIC: 7m NOT f xORIDA Si 9 •'• •••��� Siru M79 gn: Print: �/`t'J 'a' y • S\�� Print: Seal: Seal: ###44144##############44#4#4444#################44################44##444#44##444#4##########4#######4###### APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) NOTE; ALL SHEETS MUST BE REVIEWED MiIAMI-DARE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Herbert S.Saffir Permitting and Inspection Center 11805 SW 26th Street(Coral Way)•Miami,Florida 33175-2474•(786)315-2000 c� APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI—DADE FIRE RESCUE AND/OR ENVIRONMENTAL SERVICES '-_- PROVIDE MUNiciil�i4L PROCESS NUMBER HERE U. Job Address 11300 NE 2ND AVENUE,MIAMI SHORES 33161 W Z Contractor No. EF0001190 01 Qo Last four(4)digits of Qualifier No. z Folio i= P-W Lot Block Contractor Name SENTRY SECURITY INC ao go' Qualifier Name EVAN KATZ �g Subdivision PBS �z Address 10001 NW 50TH STREET#111 Metes and bounds City SUNRISE State FL Zip 33351 [ ] New Construction on [ ] Demolish Current use of property ! Vacant Land [ ] Shell Only I " C [ ] Alteration Interior [ ] Addition Attached l - W [ ] Alteration Exterior [ ] Addition Detached Descrition of Warn 1 e [ ] Relocation of Structure [ ] Re-Roof [ } Enclosure [ ] Foundation Only � [ ] Repair [ ] Tent 13 Sq.Ft. Units Floors [ ] Repair Due to Fre V ue�O�fA [ } MELD* [ ] Chg.Contractor Owner BARRY UNIVERSITY Category 04 [ ] Re-Issue m Address 11300 NE 2ND AVENUE MELE[,] MPU [ ] Re-Stamp City MIAMI SHORES S�eFL Zip 33161 [ ] MLPG pQ Revision Phone 305-899-3785 [ } MMEC �W' [ ] Not Applicable for Last four(4)digits of [ ] FIRE Fre Owner's Social Security No. w Name GRETCHEN M YNARD/SARAH RAMOR Owner z IL Address 10001 NW 50TH STREET#111 uus Address xYCity SUNRISE State FL Zip 33351 xZ city state zip i� °'K Phone 954-452-8500 % Phone I am requesting a Special Request Plan Review(SRI)to be scheduled as soon as possible at the rate of$209 for the first hour 1 and$71.50 per each additional hour in addition to the review fees.Minimum charge one-hour g 1e Request: Date: 11'g 9 2nd Request Date: 3°d Request: Date: I am requesting Optional Plan Review(OPR)to be scheduled as soon as passible at the rate of$75 for each discipline. Additional review fees may apply 0- 1s'Request: Data. Eg 2nd Request: Date: 111 Q. 3"d Request: Date: 123_01-192 4/15 BUILDING PERMIT CATEGORIES CATEGORY DESCRIPTION PERMIT TYPE BUILDING 01 GENERAL BUILDING-COMMERCIAL MBLD 02 SUB-GENERAL BUILDING-RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 COMMUNICATION TOWER MELD 15 DEMOLITION MBLD 29 METAL AWNING&STORM SHUTTER MELD 48 SCREEN ENCLOSURES MBLD 55 SWIMMING POOL MBLD 56 TENNIS COURTS(SURFACE PAVING) MBLD 86 TRAILER TIE DOWN MBLD 88 WALK-IN COOLER MBLD 91 MARINAS MBLD 92 LOW SLOPE APPLICATIONS(GRAVEL,SMOOTH MODIFIED,SINGLE PLY) MBLD 95 SHINGLES(ASPHALT,FIBERGLASS) MBLD 96 SHINGLES(METAL ROOFS/WOOD SHINGLES&SHAKE) MBLD 97 STAGE 2 VAPOR RECOVERY SYSTEM MBLD 99 SOIL IMPROVEMENT MBLD -r 0100 BULK STORAGE PROPANE TANK MBLD 0101 REMOVABLE STORM PANELS MBLD 0107 TILE ROOF MBLD 0110 WATER MAIN MBLD 0111 SITE PLAN MBLD 0112 INDOOR EVENT/EXHIBIT MBLD ELECTRICAL 04 FIRE ALARM SPECIALTY MELE 16 SPECIALTY WIRING MELE 38 GENERATORS MELE PLUMBING 0024 INTERCEPTOR/GREASE TRAPS(REPLACEMENT OR INSTALLATION THAT IS NOT PART OF A BUILDING PERMIT) MPLU LPGX 01 LIQUEFIED PETROLEUM GAS MLPG 02 MISCELLANEOUS MLPG 04 LIQUEFIED PETROL GASISTATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKSIPUMPS &POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE Miami-Dade Fire Rescue Fire Alarm Pre-Submittal Checklist MIAMF ADE Based On NFPA 72 2010'Ed.&NFPA 1 and 101 2012'Ed. i Building Dept Process Number is(Begins with C or M): Date:/ / 1 Project Name: --Z.. Is provided in title block of plans. YES NO WA 2 Address In title block shall match address in"Building Dept Computer System"and attached permit application.If address contains a specific building,floor,suite,or unit number or letter,it shall be provided in tide block,to match Building Dept.Computer System. 3 The total cost of the installation to the customer is$ and a copy of the contract or a notarized affidavit from the owner showing this amount is attached. 4 Fire Alarm Systems costing more than$5,000 are sealed or stamped by a Florida Registered Professional Engineer. 5 The total number of DEVICES and COMPONENTS being installed is 6 The alarm qualifier's state license number is(EC EF EH EY)# and a copy Is attached to plans. 7 Complete,current Manufacturer's Specification and Installation sheets are attached for all Control Units,Components,Appliances, Devices,Modules and Relays listed on Legend. K 8 is this permit application for fire alarm work a result of a Notice Of Violation(NOV)issued by Miami-Dade Fire Rescue?If yes,a copy of the Notice of Violation is attached. 9 This fire alarm:(J is required under (fill in the Occupancy Chapter&Section from NFPA 101)or, "Is a life safety equivalency or,U is a non-required system or component n This is an"EXISTING(Local)Fire Alarm System"and Is stated as such on the plans.AHJ will require documentation of prior 10 approval of system as a(Local)Fire Alarm System in the form of the original Fire Dept approved job copy set of fire alarm plans or,certified microfilm copy of same. Ei 11 This is a"NEW Local Fire Alarm m"and Is stated as such on plans. This is an"EXISTING Central Station Service Fire Alarm System"and is stated as such on the Pians.A copy of the existing 12 BUILDING UL or ETL certificate or FM Placard,specifically identifying this protected premise by address and,uniquely identifying this building's fire alarm system,is attached. If the company that issued the existing certificate or placard for this building's fire alarm system is different than the company r 13 applying for this permit;is the required Affidavit to Work on another Company's Certificated or Placarded Fire Alarm System Provided? 14 This is a NEW Certificated or Placarded "Central Station Service Fire Alarh System"and stated as such on the plans. 15 If this is a NEW"Central Station Service Fire Alarm System,'a copy of the UL orrETL oertificats.of FM placard from the contractor or,from the Central Station Service Company,issuing the building certificate/placard,is attached.' This is an"EXISTING Remote Supervising Station Fire Alarm System"and,is stated as such bn the,plans.AHJ will require 16 documentation of prior approval of system as a Remote Supervising Stag Fire Alarm System in t6 form of the original Fire Dept. aDDroved lob copy set of fire alarm plans or,certified microfilm copy of same. 17 This is an"EXISTING"Sprinkler Waterflow and Supervisory System"only and is stated as suph on plans,-,-, . This is a NEW'Sprinkler Waterflow and Supervisory System"only and Is stated as such on plans.The system is monitored off-site 18 and provides emergency fords notification through a Certificated U of Placarded L_)"Centcqj,*Statlon SeMr<e Fire Alarm"and is stated as such on the plans. t A complete detailed statement of the"SCOPE OF WORK"Is stated on the plan.Please note that the complete tenant space,In Its 1g* entirety,will be inspected for compliance with NFPA 72(2010)and NFPA 101(2012),or prior editions of these codes If applicable. Also outline scope of work with bolded dashed lines on floor plan and riser for e)dsbng systems. 20 The building Is"Naw" or,"EAsti " and is indicated as such on the plans. il 21 A description of the building is provided,Including fire sprinkler systems,fire suppression systems,number of stories,square footage per floor,and elevation of the last occupied floor if over 5 stories. 22 A location Key is provided showing the area of proposed work within the building.Also provided Is a site key for projects with y multiple buildings showing locations of all buildings with addresses 23 All Interconnected Fire Alarm Control Panels are arranged to function as a single system and monitored for Integrity per NFPA 72. 24 The Class is shown for all InIfiattrig Device Circuits(IDC),Signal Line Circuits SLC and Nolfficapon Appliance Circuits(NAC). 25 The maximum number of each device type is provided for each IDC based on device load or each SLC,based on CLASS, v r NFPA 72 and the manufacturer's speciftcations. 26 A specific"Sequence of Operation"including all alarm,supervisory,trouble and control functions such as fire sprinkler,door release,smoke control,elevator recall,suppression systems,and transmission of signals offsite,etc.are specified on the plan. r 27 The type of monitoring station,(Listed Central Station,Remote Supervising Station,Listed Proprietary Supervising Station),where alarm,trouble,and supervisory signals are transmitted to,is dearly and condsel in the"Sequence of Operations" 7C. 28 The method of communication to the monitoring station Is included on the rise If this building contains elevators that are not capable of recall,.it shall as on plans and written documentation on 29 ' elevator-contractor's letterhead stab ca that"Elevators are not abAf&9ilingI recall function",is provided, 30 If this building does not contain afire alarm system,and-the ` -'liane4is used exd6stvely for elevator recall;plans shall clears designated panel as"Elevetgr Remit Control'a rviso Panel" 31 Manufacturer,model number and uniquoisyifrbol model number is provided for each device.,module,relay,component, power supply and fire alarm control pa.ref 16. in the symbol legend. 32 Each device,module,appliance an �"nefit Is identlfiect With its own unique number and indicated on the floor plans and riser. 33 Floor plans are drawn to 1/8"scale or If using another scale,all device coverage is diagrammed on the floor plan and all room dimensions are included. LI V5 by: -Fycur ''�t Z Phone#: "1✓�1 V5 ZU Signature: Created by: MDFR 01/2015 ell THIS ISA REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 1 OF2 .4w"',' Miami-Dade Fire Rescue Fire Alarm Pre-Submittal Checklist MIAMFMM Based On NFPA 72 2010'Ed.&NFPA 1 and 101 2012'Ed. i m,= 34 All rooms&spaces are labeled Indicating their use,and the occupant load has been provided for all assembly use rooms with an occupant load of 50 or greater. 35 All new,existing,replaced or relocated devices are indicated on the floor plans and a complete riser diagram showing all new and existing devices of the entire fire alarm system is provided. 36 Ceiling He ht,Type and Angle is provided for all calif mounted devices. 37 All devices and components located in areas in which the voltage,temperature,and humidity variations exceed those conditions stated in NFPA 72,are listed for conditions and all such areas are Identified. 38 A note Is provided on the plans stating"Room containing FACP,Booster Power Supply,Voice Evacuation and Amplifier panel(s), Dialer,or Radio is mechanical) ventilated",as applicable. 39 The FACP or Remote Annunciator and as applicable EVAC panel or Remote Microphone Is located at the main entrance/lobby in single tenant buildings,or in a common area main entrance/lobby of a multi-tenant building. 40 The FACP,Communicators,Amplifiers,NAC Panels and all sub-panels are protected with a smoke detector. 41 If a complete automatically activated system,not less than one manual fire alarm pull box shall be provided to initiate system.The pull box shall be looted where AHJ specifies. 42 If a manually activated system,the travel distance to reach a pull station is less than 200'feet and within 5'feet of all required floor x and/or building exits. 43 All automatic initiating devices are shown and are located in accordance with NFPA 72,the manufacturer's specifications,and accepted engineering radices. 44 Area smoke detectors,if used shall provide coverage throughout the entire smoke compartment 45 All visual notification appliances are placed per tables in NFPA 72 and each strobe has its candela rating on the floor plan and riser. 46 All corridor spaced strobes are placed a maximum of 100'feet apart and within 15'feet from the ends of the corridor. 47 All spaces es throu hout the entire building shall meet the audible characteristics of NFPA 72 and NFPA 101. -48 Where audible appliances are provided to produce signals for sleeping areas,they shall produce a Low Frequency Alarm Signal, r NFPA 72.18.4.5.3. 49 Bell used for water flow annunciation is shown on floor plan,riser and legend.Bell shall be located so as to be visible and heard from roadway or parking area,within close proximity to Fire Dept.Connection(FDC). -50 Flow Bell sequence of operations shall state as follows: A)Flow bell shall activate upon water flow only.B)Flow bell shall continue to sound as long as water is flowing.C FACP shall not be capable of silencing Flow Bell. 51 The location of Backflow Preventer(BFP)and Post Indicating Valve(PIV)are indicated on the floor plans,riser and legend for s rinkled buildings.Also the location of the Fire Dept.Connection DC is shown on floor plaM. f 52 Wails,partitions,rads,shelves and equipment that do not extend to calling,are shown with their heights indicated on floor plan. Duct detectors or relays for dud detectors are shown on the floor plan and riser for all systems over 2000 CFM supply or 15,000 53 CFM return.Duct detectors shall derive their 24 vdc power source from the Fire Alarm System to satisfy the monitoring for integrity requirements of NFPA 72.10.17 for devices and conductors.Please show corn ll!!r=on riser. 54 A complete system riser diagram Is provided shouting each floor of the building with all zones and circuits labeled. 55 The conductor size and quantity are provided for each circuit on riser. The fire pump is monitored for.A)Pump or Motor Running,B)Loss of phase,C)Phase reversal,and,If applicable,D)Controller 56 connected to an altemate source;and are indicated at_a continuously manned location,or_the supervised fire alarm x system. (� 57 Show all relays on floor plan and clarify function on riser.(Sprinkler,Wet Chem.,Dry Chem.,Clean Agent,Foam,A/C shut-down, Door Release,Elevator Shunt-Trip,Music Shut-Down,Smoke Control and other building control functions.) I` 58 The AMPACITY of each Power Supply and Notification Appliance Circuit Is specified for each FACP&Power Supply Panel on tans.In addition,the Individual device current is specified on riser for each notification appliance Homs/Speakers/Strobes. 59 The total ACTUAL'footage to the last device along with voltage drop calculations are provided on pians for each NAC for each ower supply. 60 The wattage tap is indicated for all speakers. 61 The wattage capacity and load Is provided for each amplifier. 62 All load values for"STANDBY"&ALARM"used in calculations are Ngh-llghted on the manufacturer's specification or Installation sheets.Also,AMPACITY of epuipment/components and circuits are high-lighted on manufacturer's sheets. 63 This system Includes Emergency Voice Evacuation and is provided with 15 minutes of secondary alarm power.Required in all high rises and assembly occupancies with an occupant load greater than 300. 64 This system is being provided back up power by an emergency generator and will provide 4 hours of standby power plus the appropriate secondaalarm power.Also,clarify 120 volt panels feeding Fire Alarm components,Is connected to generator. 65 Battery calculations,detailed in chart form,showing all information required per NFPA 72.10.5.6.3.1 are provided on pians for each backpower supply, The replacement of the Fire Alarm Control Panel with anything other than the exact some make and model number panel;or the 66 addition of a Fire Alarm Control Panel which will provide or replace any of the functions of the existing FACP,shall require the fire alarm system to be up-graded to current code standards,per code of Miami-Dade County,Part III,Chapter 14,Article III,Section �( 14-66 9 & 10 K 67 If the scope of work includes greater than one-half of the entire fire alarm system's devices,then the entire fire alarm system shall be up7graded `to c�uffent code standards,per code of Miami-Dade County,Part III,Chapter 14,Article III,Section 14-66v(9). Designed by: /� �� ('�—, `� Phone#: qE54 Im Z Signature: Created by: MDFR 01/2015 THIS IS A REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 2 OF2 z • MIAMI•DADE FIRE ENGINEERING & WATER SUPPLY BUREAU 11805 SW 26 STREET, SUITE 150, MIAMI, FL. 33175 TELEPHONE (786) 315-2771 www.miamidade.govlmdfr FIRE ALARM REVIEW DISAPPROVAL COMMENTS DATE: August 19, 2015 REVIEW BY: Lt. C. Nash AI-Imam BLDG. DEPT. TK#: 331981 BLDG. DEPT. M2016013490 NAME OF PROJECT: Barry University Library ADDRESS: 11300 NE 2nd Ave 1. PER DEPT. POLICY WHEN REVISING PLANS THE REVISED SET SHALL BE A r "COMPLETE SET OF PLANS",INCLUDING ALL REVISED SHEETS(CLOUDING ALL REVISIONS AND PROVIDING APPROPRIATE NOTES DESCRIBING THE REVISIONS),AS WELL AS ALL UNREVISED SHEETS MATCHING PREVIOUSLY APPROVED SET. 2. MECHANICALLY REPRODUCE CORRECTIONS(I.E.NEW SHEETS)AND RETURN ALL PREVIOUSLY REVIEWED VOID SHEETS FOR COMPARISON, OR A FULL REVIEW FEE WILL BE ASSESSED. RESUBMIT PLANS FOR"DROP-OFF" FOR REWORK (For questions,concerns,or clarification on disapproval comments,you must schedule a Design Professional Appointment. Appointments are held on Monday's&Thursday's only. Appointments shall be scheduled the previous working day of the appointment between the hours of 8:30 am and 4:30 pm by calling 786-315-2771 or logging in to www.miamidade.govibuilding ' Please know the reviewer's name and Dade County Process# You may now visit the Miami Dade Building Department's website and view the following: • Track and check status and of Plans Review. • View disapproval comments. • Schedule a Design Professional Appointment for reworks. www.miamidade.gov/building You also may visit the Miami Dade Fire Rescue website and view the following: Submittal Application Pre-Submittal Checklist Useful ResourcesAGuldelines Fee Schedule www.miamidade.gov/mdfr r