RC-14-349 (2) Miami Shores Village
Building Department FEB a 4 zot�
10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel: (305)795.2204 Fax:(305)756.8972 BYE
INSPECTION'S PHONE NUMBER:(305)762.4949
FBC 20
BUILDING Permit No.
PERMIT APPLICATION Master Permit No.f;C. 14 H
Permit Type: �� QV t jb!&je.
JOB ADDRESS: /0.3r 1UO 96 SyAeW
City: Miami Shores County: Miami Dade Zip: 3 3/J'R
Folio/Parcel#: 11• ,3.A06. O N- 3?3 0
Is the Building Historically Designated:Yes NO ✓ Flood Zone:
OWNER.Name(Fee Simple Titleholder): 't r`a n CSC PGi�M`S"Q Phone#: 6"9f19- q 13
Address: 10 S S NE_ "1 ST
'�t� p: 331 3Y
Ci 1 1 S ti�rt'� State: �t— Zi
Tenant/Lessee Name: Phone#:
^
Email: ► r101 'M Gl \ C Dui C.0 a d
CONTRACTOR:Company Name:?tt.eS®q5 &eNe Co�J7'Ra4TO.eS sNL. Phone#:3DS'a9r9S9 J
Address: 16 Q SD 5 w 90 Ave.
City: Aa L'W elry t3 s!Y State: �'LoR�da Zip: _3.31.77
Qualifier Name: A 0-11 o y Y S. i jaAXoA Phone#•.�5� `'YJ 7'?
State Certification or Registration#: C(Z O'S V-TS'S/ Certificate of Competency#:
Contact Phone#: 301- Z S9• 9S9 8 Email Address: dA o6 r4 a(, Q? Pact-S 0,0-r A G• C.0 Ai
DESIGNER:Architect/Engineer. C.7 S Aar.!►ITcr. . PIaGC Phone#: S64•9Ztb �'r 3'85
Value of Work for this Permit:$ S5_00_1 nzr Square/Linear Footage of Work:_ '3133 3
Type of Work: DAddress OAlteration (New ORepair/Replace ODemolition
Description of Work: N r--W &Z ou H DUP Z STD aY S/N RJ'a jCAM1 Y lQ i;SI.DGJN ru
�*�+,���a
Submittal Fee$ O• Permit Fee$ CCF$ CO/CC$ Igo 0
Scanning Fee$ Radon Fee$ DBPR$ Bond$
Notary$ Training/Education Fee$ Technology Fee$
Double Fee$ Structural Review$
TOTAL FEE NOW DUE$ __ 3
Bonding Company's Name(if applicable) Aye. 3
Bonding Company's Address
City t State Zip
a'
Mortgage Lender's Name`(kapplicable)
tf
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOII,ERS,HEATERS,TANKS and AIR COMIJONES,
zu
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning. , : , , • . •
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR, PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature 044f
Owner or Agent Contractor
The foregoing instrument was acknowledged before me this j - The foregom instrument was acknowledged before me this
day of�g&A Y 20 A byJ—Nq&l Pa l vls"d day of4J4Y,204,,by
who is personally known to me or who has produced who is personally known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBIJC: ' 4 NOTARY PUBLIC:
Sign: Jt W /U ,_Q Sign: j
Print: W. Ileioe(L Print: �bay--d W. lea a9L
My Commission gxpires: My Commission
DAVID W.HAMEL
Notary Public-State of Florida.
DAVID W.HAMEL
•• My Comm.Expires Apr 24,2015 Via° o•, Notary Public-State of Florida
�r�r�r�r,�,�,r,�,�,�,��r�r,�ae,�,��a,s,x,x w' °'t,�,v�ra��,��r�sr��ult5��r�r �r,x,��x��,ra�awr�r�r�r�rar�ra�a��r,�,u '• ■• My Comm.Expires Apr 24,2015
'•�.� Bonded Through National Notary Assn.
off$ Bonded Through National Notary Assn.
APPROVED BY Plans Examiner g
4-1
11 qJJ�y ,y
Structural Review Clerk
(ReAsed3/12/2012XRevised 07/10/07XRmised 06/10/2009)(Revised 3/15/09)
Miami Shores Village
Building Department
R 10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
CONTRACTORS' REGISTRATION Fax: (305) 756.8972
ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED.
IF CONTRACTOR IS A F1ASTATE CERTIFIEDONTRACTOR:
A. COPY OF QUALIFIER'S STATE LICENCES
B. COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF LIABILITY INSURANCE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY:
A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER
B. COPY OF LOCAL BUSINESS TAX RECEIPT
B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT
C. COPY OF LIABILITY INSURACE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
*YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW:
MIAMI SHORES VILLAGE BLDG DEPT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
COMPLETE CONTTR�ACTORIS INFORMATION
BUSINESS NAME: 't-a,tgoyk C4we.?cct
BUSINESS ADDRESS: 1620 SuJ q0 ,Ay _ CITY Pcc�� �m9
STATE TT ZIP CODE 633/57
BUSINESS PHONE: ( 3 ) 2yq-959 7 FAX NUMBER L2-VS')
CELL PHONE( 76(x ) 370. 9?q9 QUALIFIER'S NAME: .r�u�i�uY PQat'SBa�S
QUALIFIER'S LIC NUMBER: G 6[C. 0
Created on 3/19109 BY MLDV I RV 3126109 MLDV I RV 6127111 AS
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395
1940 NORTH MONROE STREET
` TAT•?• HASSEE FL 3239.9-0783
N
M
� O
STC
�4c ti
7F 1i yW�
F
I - r
S I one million
z nal Regulation' Y
Ptd ' i31T 'tT Q
brokers,from
y strong.
n� 3 serve you bene �;: ...
dalicense.com. *�
d e regulations thatg
w about the ;
ably.We
stomers. '
dour new licenses 4 f zzt'
s z
p x Ei Yi9� aap� s3j r, % }1$fl20
FA
'::}p r}z♦ >v„ `fib s< rs•
L
e
V
O
• .
x ` rt y}, ♦ �i '� a r 1.. ) t.. J 4 J t. _i ( p
y .+.4f'✓4"rJ�iffiNx F / s y>e<YJ r � }�?^ R� 1�... � r } ' t�♦43 >r ��}4,>♦ } _yc t
x
Y w!. ,♦ _yam „•p �3,? -�/ L.. �f/•\yf�. 5..�F.�'j^�r.Yj.�t:+ �� -.. ! �,,,•.td .�q'z� is f♦ L S /°{ m1 ��, 1
�'.\r Wil\' a'b z/ .:/, fir,=6Z� •+�D♦'rx�.�� 'x\?';:.:. a b.ra1 ,}.,:.t• :.i.♦r .•_.. ,1> riy y}+♦' '>� •s�.�,'�r z:�� r } /
:
S f ,,1:.y£PL��` j rk•F£ f ikn-rt b '�j
�3l P PTf .i,;q',r _ _ r ✓ agr t -s:j< jai -tf _
t /
C.
PIP,,
A X-11
• h
3! •1�„>,+m ?} a.•r,afcr,•n rL„1 v ♦ ,a - .' 3 i ya _ / f .' { ..'
i '• sin i> #r
t J .:lE �� r�. moi- r r> ruy♦ It'd�'ht .#t a\
�9a\$ �r•L� �z�a b /rta t 3r�� _�♦ -it = j ._ ♦ ,Lp �. � �� �z♦-:� ,-f ♦ a:
�'3A,:..�� rX♦L Cod" �'•Y i>i'� ��a ifs�♦ �♦ T� � 4� &♦ t �irn lbk,. ♦5. 5.3 _,t tr W,s>..LL`rt /: t'. ,,J
L / �ti d7p r j d t• f ,. } y w'dr ��' /� ��.:/,� .'�♦}, � - 4. - >�.r, t �,dy;}��,�}' '�.,Jf
0$.. �, » J� O' }.,w,:sfe a♦ i4°j,4R2/ di / _ ...Yi T'S, >�d l.�NNE" Yjs
/ �r`rt R� ♦�, 'rz�> / Y}"/ / }�r�„,"x 8" , ': .✓,.
+
PARSGEN-01 MQUINTERO
'® CERTIFICATE OF LIABILITY INSURANCEDATE%UMMY"
5/14/2014
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endoreemen s.
PRODUCER CONTACT
NAME:
Collinsworth,After,Fowler S French,LLCPHONE (305)822-7800 Ne (305 362-2443
8000 Governors Square Blvd E-Maa
Suite 301 ADDRESS:
Miami Lakes,FL 33016
INSURER(S)AFFORDING COVERAGE NAIL#
INSURERA:Scottsdale Insurance Company 41297
INSURED INwRERB:Vlnln s Insurance Company
Parsons General Contractors,Inc. INSURERC:
16950 S.W.80th Avenue INSURER D:
Palmetto Bay,FL 33157 INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,-TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR ADM au POLICY EFF POLICY EXP
LTR TYPE OF INSURANCE POLICY NUMBER LIMITS
GENERAL LIABILITY EACH OCCURRENCE $ 1,000,00
A X COMMERCIAL GENERAL LLABIuTY CPS1828015 8/1212013 .811212014 PREMISES Ocx Mwm $ 100,00
CLAIMS-MADE XO OCCUR MED EXP are pmm) $ 5,00
PERSONAL&ADV INJURY $ 1,000,00
GENERALAGGREGATE $ 2,000,00
OEITLAGGREGATEUMITAPPLIES PER: PRODUCTS-COMPIOPAGG $ 2,000,00
X `POLICY PRO- X LOC $
BINED MIT
AUTOMOBILE LIABILITY I U
>` ANYAUTO
BODILY-INJURY(Perpersw:) $
AUTOS
SCHEDULED BODILY INJURY(Par-ddeM $
AUTOS
NON-OWNED Per acd $
HIRED AUTOS AUTOS
X' UMBIiURJAA LIAR X OCCUR EACH OCCURRENCE $ 2,000;00
A EXCESS LIAR C�Mg MApE 36162 1/10/2014 8/1212014 AGGREGATE $ 2,000'00
DED RETENTION$ $
WORKERS COMPENSATION X IWC S ATU- I JOTH-
AND EMPLOYERS'LIABILITYTORY LIMITS ER
YIN,
B ANY PROPRIEfOWPARTNER/EXECUTNE NIA 013735001 1MI2014 11112015 E.LEACH ACCIDENT $ 500,00
OFFICERIMEMBER EXCLUDED? -
(MarWatoryr In NH) E.L DISEASE-EA EMPLOYE $ 500,00
If Lmler
DESM ON OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,00
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additnw Runaft 8ehadute,B mm space M mqubed)
General Contracting
Project Location:1036 NE 86th Street,Miami Shores,FL
Description:Palmleano Residence/New 2 story single family residence.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
a Building De THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
Miami Shores Villa
g g pL ACCORDANCE WITH THE POLICY PROVISIONS.
10050 NE 2nd Avenue
Miami Shores,FL 33138
AUTHORQED REPRESENTATIVE
m 1888-2010 ACORD CORPORATION. All rights reserved.
ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD
an Iup�
` 10050 N.E. SECOND AVE.
loRtDp' MIM SHORES,FLORIDA 33138-2382
Telephone: (305) 795-2207
Fax: (305) 756-8972
DAVID A. DACOUISTO,AICP
PLANNING&ZONING DIRECTOR
DEVELOPMENT ORDER
File Number: PZ,4-13-201334
Property Address: 1035 NE W Street
Property Owner/Applicant: Eric and Ingrid Palmbano
,
Address: 1035 N 96Street,Miami Shores,33138
Whereas,the applicant Eric and Ingrid Palmisano(Owner),has filed an application for
site plan review before the Planning Board on the above property. The applicant sought
approval as follows: Special site plan review and approval.New residence. Metal Roof.
Whereas, a public hearing was held on July 27, 2013 and the Board, after having
considered the application and after hearing testimony and reviewing the evidence
entered,finds:
1. The application was made in a manner consistent with the requirements of
the Land Development Code of Miami Shores Village.
2. The conditions on the property and the representations made at the hearing
merit consideration and are consistent with the requirements of. the Land
Development Code.
The Board requires that all further development of the property shall be performed in a
manner consistent with the site plan, drawings, and the conditions agreed upon at the
hearing:
1) Approval is granted for a 2,590 square foot residence including the garage,
covered entry and rear porch, 1,500 square feet of living space on the main
floor and 1,914 square feet on the second story with 4 bedrooms including
a master,3 bedrooms and a laundry room.
2) Applicant to provide a landscaping plan agreeable to the Planning and
Zoning director.
3) Applicant to obtain all required permits from the Department of
Regulatory and Economic Resources,Environmental Plan Review
Division.
4) Applicant to obtain all required building permits before beginning work.
5) Applicant to meet all applicable code provisions at the time of permitting.
Page 1 of 2
DO PZ-6-13-201334.PaWsano
6) This zoning permit will lapse and become invalid unless the work for
which it was approved is started within one(1)year of the signing of the
development order by the board chair,or if the work authorized by it is
suspended or abandoned for a period of at least one(1)year.
The application with conditions was passed and adopted this 27a' day of June, 2013 by
the Planning and Zoning Board as follows:
Mr. Abramitis YE
Mr.Busts M
Mr.Reese "S
Mr.Zelkowitz YES
Chairman Fernandez YRS
Date M.Ferran
C�Planning Board
Page 2 of 2
DO PZ-6-13-201334 Paimisano
• FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: PALMISANO RESIDECE Builder Name:
Street: 1305 NE 96TH STREET Permit Office:
City,State,Zip: MIAMI SHORES,FL,33138- Permit Number.
Owner. Jurisdiction: 232600
Design Location: FL,Fort Lauderdale
1. New construction or existing New(From Plans) 9. Wall Types(3803.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 3553.00 ft'
b.Frame-Wood,Exterior R=11.0 100.00 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=5.0 90.00 ft'
d.other(see details)
4. Number of Bedrooms 13 � R= 60.00 ft'
5. Is this a worst case? No 10.Ceiling Types(2563.1 sgft.) Insulation Area
a.Under Attic(Vented) R=19.0 2563.10 ft'
6. Conditioned floor area above grade(ft2) 3442. b.N/A R= ft'
Conditioned floor area below grade(ftp 0 c.N/A R= ft'
11.Ducts R ft'
7. Windows(765.5 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:master bedroom 6 344.2
a. U-Factor Dbl,U=0.56 765.50 ft' b.Sup: Attic,Ret:Attic,AH:master bedroom 6 294.x.
SHGC: SHGC=0.43
b. U-Factor N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 48.0 SEER:17.30
c. U-Factor. N/A ft' b.Central Unit 59.0 SEER:16.00
SHGC: 13.Heating systems kBtu/hr Efficiency 1-1
d. U-Factor. N/A ft' a.Electric Strip Heat 17.0 COP:1.00
SHGC: b.Electric Strip Heat 17.0 COP:1.00
Area Weighted Average Overhang Depth: 5.436 ft.
Area Weighted Average SHGC: 0.430 14.Hot water systems
`
8. Floor Types (1239.5 sgft.) Insulation Area a.Electric Cap:60 gallons1,
a.Slab-On-Grade Edge Insulation R=5.0 1239.50 ft' b. Conservation features EF•
b.N/A R= ft' None
c.N/A \`1lllllf�j/
15.Credits CF,CV,
® i><af 4?roposed Modified Loads: 101.25 PASS
Glass/Floor Area:
�� dotal,$ dard Reference Loads: 126.48
I hereby certify that1holans and specifications icove-red by Review of the plans and o fTl6 S
this calculation are-66 with the Florida#Edorgy specifications covered by this 1+ r± 0
Code. ® / ` E calculation indicates compliance co` <ld Hs;8�`„�+{
with the Florida Energy Code.
PREPARED BY: e� Before construction is completed
DATE- this building will be inspected for p;;
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. x'40 ,�
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed In accordance with 403.2.2.1.1.
- Compliance requires an envelope leakage test report,by a Flora in accordance with Table B-1.1.2.
114
IC _
MAY 2.120%
kD��nerg9/26!20131:52 PM ®USA-Fla 201 e 1 pliant Software Page 1 of 7
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONST'RUCT'ION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: PALMISANO RESIDECE Builder Name:
Street: 1305 NE 96TH STREET Permit Office:
City,State,Zip: MIAMI SHORES,FL,33138- Permit Number.
Owner. Jurisdiction: 232600
Design Location: FL,Fort Lauderdale
1. New construction or existing New(From Plans) 9. Wall Types(3803.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 3553.00 fta
b.Frame-Wood,Exterior R=11.0 100.00 fta
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=5.0 90.00 ftz
4. Number of Bedrooms 13 d.other(see details) R= 60.00 ft'
5. Is this a worst case? No 10.Ceiling Types.(2563.1 sgft.) Insulation Area
a.Under Attic(Vented) R=19.0 2563.10 ftz
6. Conditioned floor area above grade(ft) 3442 b.N/A R= ftz
Conditioned floor area below grade(ftp 0 c.N/A R= ft'
11.Ducts R ftz
7. Windows(765.5 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:master bedroom 6 344.2
a. U-Factor Dbl,U=0.56 765.50 ft' b.Sup: Attic,Ret:Attic,AH:master bedroom 6 244.2
SHGC: SHGC=0.43
b. U-Factor. N/A fta 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 48.0 SEER:17.30
c. U-Factor. N/A ft' b.Central Unit 59.0 SEER:16.00
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A fta a.Electric Strip Heat 17.0 COP:1.00
SHGC: b.Electric Strip Heat 17.0 COP:1.00
Area Weighted Average Overhang Depth: 5.436 ft.
Area Weighted Average SHGC: 0.430 14.Hot water systems
8. Floor Types (1239.5 sgft.) Insulation Area a.Electric Cap:60 gallons
•
a.Slab-On-Grade Edge Insulation R=5.0 1239.50 fta b. Conservation features EF:0.920
b.NIA R= ft' None
c.N/A I l l l l�� / ft'
15.Credits CF,CV,Pstat
® �\�" Ioposed Modified Loads: 101.25 PA
Glass/Floor Area: 00 � C E m ��
&a1' t mrd Reference Loads: 126.48
_o
1 hereby certify that thb ns and sp6cifications cpy@rgl by Review of the plans and BTS t
this calculation are i liance with thoFlorida Fir y specifications covered by this ti �� �}
Code. o�', o� calculation indicates compliance c" ,1 a
with the Florida Energy Code. 9
PREPARED BY: Before construction is completed
DATE: this building will be inspected for +;,�;'I'
compliance with Section 553.908 * r,
I hereby certify that this building,as designed,is in compliance Florida Statutes. ,
with the Florida Energy Code. app
WME
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed In accordance with 403.2.2.1.1.
- Compliance requires an envelope leakage test report,by a Florida Class 1 Rater,In accordance with Table B-1.1.2.
9/26/20131:52 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
` PROJECT
Title: PALMISANO RESIDECE Bedrooms: 13 Address Type: Street Address
Building Type: User Conditioned Area: 3442 Lot#
Owner. Total Stories: 2 Biock/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 1305 NE 96TH STREE
Permit Office: Cross Ventilation: Yes County: Miami-Dade
Jurisdiction: 232600 Whole House Fan: No City,State,Zip: MIAMI SHORES,
Family Type: Single-family FL, 33138-
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
�/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Lauderdale FL FORT LAUDERDALE 1 43 91 70 75 321.5 60 Low
BLOCKS
Number Name Area Volume
1 Block1 1490 11920
2 Block2 1952 16162
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 master bedroom 416 3744 Yes 5 4 1 Yes Yes Yes
2 20 MASTER CLOS 130 1170 No 0 0 1 Yes Yes Yes
3 21 Master Bathroo 176 1408 No 0 0 1 Yes Yes Yes
4 14 Bedroom 1 186 1488 No 0 1 1 Yes Yes Yes
5 15 Bathroom 1 49 392 No 0 0 1 Yes Yes Yes
6 12 Bathroom 2 80 640 No 0 2 1 Yes Yes Yes
7 21 closet 2 49 392 No 0 0 1 Yes Yes Yes
8 11 closet 3 49 392 No 0 0 1 Yes Yes Yes
9 14 bedroom 221 1768 No 0 3 1 Yes Yes Yes
10 10 bedroom 3 221 1768 No 0 3 1 Yes Yes Yes
11 17 hall 105 840 No 0 0 1 Yes Yes Yes
12 laundry 63 504 No 0 0 1 Yes Yes Yes
13 upper reception 207 1656 No 0 0 1 Yes Yes Yes
14 3living 435 3480 No 0 0 1 Yes Yes Yes
15 bath 1 54 432 No 0 0 1 Yes Yes Yes
16 3 dining 285 2280 No 0 0 1 Yes Yes Yes
17 5 kitchen 160 1280 No 0 0 1 Yes Yes Yes
18 pantry wine 64 512 No 0 0 1 Yes Yes Yes
19 mud 64 512 No 0 0 1 Yes Yes Yes
20 dance media 221 1768 No 0 0 1 Yes Yes Yes
21 lower reception 207 1656 No 0 0 1 Yes Yes Yes
9/26/20131:52 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-0n-Grade Edge Insulatio master bedroom 85 ft 5 933.8 ft2 ____ 0 0 1
2 Slab-On-Grade Edge Insulatio master bedroom 45 ft 5 305.68 ft2 ____ 0 0 1
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
�/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 2183 ft2 488 fta White 0.55 No 0.55 No 19 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1952 ft2 N Y
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) master bedroom 19 610.6 f12 0.11 Wood
2 Under Attic(Vented) master bedroom 19 1952.48 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
R-vnl,,A Et In Et In Ares, R-Alaille Fraction Absor rrarle%
1 N Exterior Concrete Block-Int Insuhaster bedro 5 17.4 0 10 0 174.0 ft2 0 0 0.5 0
2 S Exterior Concrete Block-Int Insul 3 living 5 25 0 10 0 250.0 ft2 0 0 0.5 0
- 3 S Exterior Concrete Block-Int Insataster bedro 5 6 0 10 0 60.01? 0 0 0.5 0
4 N Exterior Concrete Block-Int Insubaster bedro 5 17.4 0 10 0 174.0 ft2 0 0 0.5 0
_ 5 N Exterior Concrete Block-Int Insaiaster bedro 5 10 0 10 0 100.0 ft2 0 0 0.5 0
-6 S Exterior Frame-Wood master bedro 11 10 0 10 0 100.0 ft2 0 0 0.5 0
7 N Exterior Concrete Block-Int Insubaster bedro 5 8 0 10 0 80.0 ft2 0 0 0.5 0
8 E Exterior Concrete Block-Int Insotaster bedro 5 9 0 10 0 90.0 ft2 0 0 0.5 0
9 E Exterior Concrete Block-Int Insobaster bedro 5 8 0 10 0 80.0 ft2 0 0 0.5 0
10 S Garage Frame-Wood master bedro 5 9 0 10 0 90.0 ft2 0 0 0.5 0
_11 S Exterior Concrete Block-Int InsaEaster bedro 5 18 0 10 0 180.0 ft2 0 0 0.5 0
_12 W Exterior Concrete Block-Int InscAaster bedro 5 12.3 0 10 0 123.0 ft2 0 0 0.5 0
_13 W Exterior Concrete Block-Int Insotaster bedro 5 14 0 10 0 140.0 ft2 0 0 0.5 0
14 N Exterior Concrete Block-Int Instdaster bedro 5 16 0 10 0 160.0 ft2 0 0 0.5 0
15 E Exterior Concrete Block-Int Insubaster bedro 5 41 0 10 0 410.0 ft2 0 0 0.5 0
-16 S Exterior Concrete Block-Int Insuhaster bedro 5 10 0 10 0 100.0 ft2 0 0 0.5 0
17 W Exterior Concrete Block-Int Insu9aster bedro 5 8 0 10 0 80.0 ft2 0 0 0.5 0
_18 S Exterior Concrete Block-Int Insubaster bedro 5 12.2 0 10 0 122.0 ft2 0 0 0.5 0
19 E Exterior Concrete Block-Int Insobaster bedro 5 14.4 0 10 0 144.0 ft2 0 0 0.5 0
_20 N Exterior Concrete Block-Int Insubaster bedro 5 20 0 10 0 200.0 ft2 0 U 0.5 0
_21 N Garage Concrete Block-Int Insolaster bedro 5 6 0 10 0 60.0 ft2 0 0 0.5 0
_22 W Exterior Concrete Block-Int Insubaster bedro 5 14 0 10 0 140.0 ft2 0 0 0.5 0
9126/20131:52 PM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7
` WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ R-Alahle Et In Et In Area R--Vahle Fraction Ahsor GcadA%
23 N Exterior Concrete Block-Int Insubaster bedro 5 18 0 10 0 180.0 ft2 0 0 0.5 0
_24 W Exterior Concrete Block-Int Insubaster bedro 5 12.3 0 10 0 123.0 ft2 0 0 0.5 0
_25 S Exterior Concrete Block-Int Insubaster bedro 5 18 0 10 0 180.0 ft2 0 0 0.5 0
_26 W Exterior Concrete Block-Int Insubaster bedro 5 12.3 0 10 0 123.0 ft2 0 0 0.5 0
_27 W Exterior Concrete Block-Int Insubaster bedro 5 14 0 10 0 140.0 ft2 0 0 0.5 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W Insulated master bedro None .46 3 7 21 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Double Yes 0.56 0.43 68.3 ft2 18 ft 0 in 12 ft 0 in None None
2 S 2 Metal Low-E Double Yes 0.56 0.43 30.0 ft2 0 ft 0 in 0 ft 0 in None None
3 S 3 Metal Low-E Double Yes 0.56 0.43 4.0 ft2 0 ft 0 in 0 ft 0 in None None
4 N 4 Metal Low-E Double Yes 0.56 0.43 42.0 ft2 10 ft 0 in 1 ft 0 In None None
5 N 5 Metal Low-E Double Yes 0.56 0.43 45.0 ft2 0 ft 0 in 0 ft 0 in None None
6 S 11 Metal Low-E Double Yes 0.56 0.43 48.8 ft2 10 ft 0 in 1 ft 0 in None None
7 S 11 Metal Low-E Double Yes 0.56 0.43 30.0 ft2 0 ft 0 in 0 ft 0 in None None
8 W 13 Metal Low-E Double Yes 0.56 0.43 90.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 1
9 N 14 Metal Low-E Double Yes 0.56 0.43 63.0 ft2 10 ft 0 in 1 ft 0 in None None
10 E 15 Metal Low-E Double Yes 0.56 0.43 30.0 ft2 0 ft 0 in 0 ft 0 in None None
11 S 18 Metal Low-E Double Yes 0.56 0.43 25.0 ft2 0 ft 0 in 0 ft 0 in None None
12 N 20 Metal Low-E Double Yes 0.56 0.43 42.0 ft2 10 ft 0 in 1 ft 0 in None None
13 N 23 Metal Low-E Double Yes 0.56 0.43 48.8 ft2 10 ft 0 in 1 ft 0 in None None
14 N 23 Metal Low-E Double Yes 0.56 0.43 30.0 ft2 0 ft 0 in 0 ft 0 in None None
15 S 25 Metal Low-E Double Yes 0.56 0.43 48.8 ft2 10 ft 0 in 1 ft 0 in None None
16 S 25 Metal Low-E Double Yes 0.56 0.43 30.0 ft2 0 ft 0 in 0 ft 0 in None None
17 W 27 Metal Low-E Double Yes 0.56 0.43 90.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds Exterior 1
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 384 ft2 384 ft2 64 ft 8 ft 11
9/26/20131:52 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH .000099 890.9 48.91 91.98 .0838 1.9036
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1
2 Electric Strip Heat None COP:1 17 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:17.3 48 kBtu/hr 1440 cfm 0.75 1 sys#1
2 Central Unit Split SEER:16 59 kBtu/hr 1770 cfm 0.75 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 60 gal 160 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None fta
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 344.2 ft Attic 86.05 ft Default Leakage master bedr (Default) (Default) 1 1
2 Attic 6 244.2 ft Attic 86.05 ft Default Leakage master bedr (Default) (Default) 2 2
TEMPERATURES
Programable Thermostat:Y [ Ceiling Fans:
Heat ng Jan Feb Mar
[ ]Ap' L May �Jun Ii Jul �Aug �Sep Oct Nov Dec
�OctNov
X�Nov �Dec
Venting Jan Feb Mar [X] [ Jun Jul Aug Sep
9/26/20131:52 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 0 - 0% 2-Central Unit
9/26/20131:52 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 1305 NE 96TH STREET PERMIT#:
MIAMI SHORES, FL, 33138-
MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283.Windows and
doors=0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)or shutoff(gas). Circulating system pipes insulated to= R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78%(82%after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
9/26/20131:52 PM EnergyGauge®USA-F1aRes2010 Section 405.4.1 Compliant Software Page 7 of 7
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 Pae 1
Project Report
General Project Information
Project Title: Palmisano Residence
Designed By: Lei
Project Date: August 29,2013
Company Name: Loucks Engineering
rbe�sin a
Reference City: Miami, Florida
Building Orientation: Front door faces North
Daily Temperature Range: Low
Latitude: 25 Degrees
Elevation: 7 ft.
Altitude Factor. 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter. 47 44.1 80% n/a 72 n/a
Summer: 90 77 56% 50% 75 55
Check Figures
Total Building Supply CFM: 3,103 CFM Per Square ft.: 0.901
Square ft. of Room Area: 3,442 Square ft. Per Ton: 475
Volume(W)of Cond. Space: 34,429
Buildin 'Loads
Total Heating Required Including Ventilation Air. 39,020 Btuh 39.020 MBH
Total Sensible Gain: 71,559 Btuh 82 %
Total Latent Gain: 15,436 Btuh 18 %
Total Cooling Required Including Ventilation Air. 86,995 Btuh 7.25 Tons(Based On Sensible+Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26, 2013, 1:29 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 Page 2
Load Preview Report
Net: jai Sen; Lat Net' Sen Sys j Sys; Sys4 Duct
Scope Tons rroni Area! Gain; Gain ?Gain! Loss Htg F FMClg i Act; Size
CFM: CFM' CFM
Building 725 475 3,442 71,559 15,436 86,995 39,020 435 3,103 3,103
System 1 3.60 414 1,490 35,159 8,077 43,236 18,487 209 1,533 1,533 2202
Ventilation 1,434 3224 4,658 2,390
Duct Latent 2,183 2,183
Zone 1 1,490 33,725 2,670 36,395 16,097 209 1,533 1,533 22x12
6-3 Living- 435 7,648 630 8278 4,603 60 348 348 3-6
7-Bath 1 54 530 0 530 494 6 24 24 1-6
16-3 Dining 285 5,726 1230 6,956 1,917 25 260 260 3--6
17-5 10lohen 160 4,767 705 5,472 1,939 25 217 217 2-6
18-Pantry/Wine 64 1,021 0 1,021 730 9 46 46 14
19-Mud 64 958 0 958 543 7 44 44 1-6
20-2 Dance/media/office 221 5249 105 5,354 2,913 38 239 239 2-6
21--Lower Reception 207 7,827 0 7,827 2,958 38 356 356 3-6
System 2 3.65 535 1052 36,400 7,359 43,759 20,532 226 1,570 1,570 2202
Ventilation 1,879 4224 6,103 3,131
Zone 1 1,952 34,521 3,135 37,656 17,401 226 1.570 1,570 22x12
1-22 Master Bedroom 416 8,539 210 8,749 3,760 49 388 388 4-6
2-20 Master Closet 130 783 0 783 1,037 13 36 36 1-6
3-21 Master Bath 176 2,254 600 2,854 2,024 26 102 102 1-6
4-14 Bedroom 1 186 3,183 405 3,588 1,556 20 145 145 2-6
5-15 Bath 1 49 849 105 954 206 3 39 39 1-6
8-12 Bath 2 80 1,137 105 1242 438 6 52 52 1-6
9-21 Closet 2 49 454 0 454 60 1 21 21 1-6
10-11 Closet 3 49 454 0 454 60 1 21 21 1-6
11-14 Bedroom 2 221 4,454 405 4,859 2,587 34 202 202 2-6
12-10 Bedroom 3 221 4,401 705 5,106 2,637 34 200 200 2-6
13-17 hall 105 1268 0 1268 129 2 58 58 14
14-18 Laundry 63 1,093 600 1,693 77 1 50 50 1-6
15--Upper Reception 207 5,655 0 5,655 2,830 37 257 257 3-6
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26,2013, 1:29 PM
• Rhvac-Residential S Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 Page 3
Duct Size Preview
Room or Minimum Maximum; Rough.; Design: SP Duct Duct Htg Cig Act. Duct
Duct Name _..W.. ..._.w_.._ Veiocityi Velocityi Factor LAW Lossi Velocity Length; Flow :_ Flow Flow ! Size
System 1
Supply Runouts
Zone 1
6-3 Living= 550 900 0 0.1 590.3 60 3911; 348 3-6
7-Bath 1 550 900 0 0.1 122.6 6 24 24 1-6
16-3 Dining 550 900 0 0.1 442 25 260: 260 3--6
17-5 Kitchen 550 900 0 0.1 551.9 25 217 217 2-6
18-Pantry/Wine 550 900 0 0.1 236.4 9. 46 46 1-6
19-Mud 550 900 0 0.1 221.7 7 44 44 1-6
20-2 Danceimedia/office 550 900 0 0.1 607.7 38: 239 239 2-6
21--Lower Reception 550 900 0 0.1 604.1 38 356 356 3-6
Other Ducts in System 1
Supply Main Trunk 650 900 0 0.1 836.4 209 1,533 1533 22x12
System 2
Supply Runouts
Zone 1
122 Master Bedroom 550 900 0 0.1 494.3 49 3811 388 4-6
2-20 Muer Closet 550 900 0 0.1 181.2 13; 36 36 1-6
3-21 Master Bath 550 900 0 0.1 521.9 26 1.02' 102 1-6
4-14 Bedroom 1 550 900 0 0.1 368.5 20;, 145,, 145 2--6
5-15 Bath 1 550 900 0 0.1 196.5 3 3 .= 39 1-6
8-12 Bath 2 550 900 0 0.1 263.2 6 52' 52 1-6
9-21 Closet 2 550 900 0 0.1 105.1 1 21: 21 1-6
10-11 Closet3 550 900 0 0.1 105.1 1
21 1-6
11-14 Bedroom 2 550 900 0 0.1 515.7 34 X02: 202 2-6
12-10 Bedroom 3 550 900 0 0.1 509.6 34 200; 200 2-6
13-17 hall 550 900 0 0.1 293.6 21 58 1-6
14-18 Laundry 550 900 0 0.1 253.1 150, 50 1-6
15--Upper Reception 550 900 0 0.1 436.5 37` 257, 257 3-6
Other Ducts in System 2
Supply Main Trunk 650 900 0 0.1 856.1 228.- 1•,570 1,570 2202
Summary
System 1
Heating Flow: 209
Cooling Flow: 1533
System 2
Heating Flow: 226
Cooling Flow: 1570
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26,2013, 1:29 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale FL 33309 10 Page 4
Total Building Summary Loads
Component Area Sen Lat. Sen Total
Desc` tion Quan Loss Gain Gain Gain
1A-cw-o: Glazing-Single pane, operable window, clear, 435.5 9,801 0 11,795 11,795
wood frame, u-value 0.9, SHGC 0.64
1A-cw-o: Glazing-Single pane, operable window, clear, 150 3,375 0 5,491 5,491
wood frame, u-value 0.9, SHGC 0.64
1A-cb-o: Glazing-Single pane, operable window, clear, 180 4,860 0 9,340 9,340
metal frame with break, outdoor insect screen with
100%coverage, light color drapes with medium
weave with 50%coverage, u-value 1.08, SHGC 0.75
13A-4fcb:Wall-Block, board insulation only, R-4 board 512.8 1,538 0 1,188 1,188
insulation,filled core, brick finish
12B-0sw:Wall-Frame, R-11 insulation in 2 x 4 stud 1782.2 4,323 0 4,859 4,859
cavity, no board insulation, siding finish,wood studs
13A-4fcb: Part-Block, board insulation only, R-4 board 100 180 0 180 180
insulation, filled core, brick finish
13A-4fcs: Wall-Block, board insulation only, R-4 board 552.5 1,615 0 1,249 1,249
insulation,filled core, siding finish
13A-4fcs: Part-Block, board insulation only, R-4 board 90 158 0 158 158
insulation,filled core, siding finish
16CR-19: Roof/Ceiling-Under Attic with Insulation on Attic 2563.1 3,139 0 5,526 5,526
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic with Radiant Barrier, Dark
Asphalt Shingles or Dark Metal,Tar and Gravel or
Membrane, R-19 insulation
22C-5pl-t: Floor-Slab on grade, Horizontal board 130 3,186 0 0 0
insulation extends 4'under slab,tile covering, R-5
insulation, passive, light dry soil
Subtotals for structure: 32,175 0 39,786 39,786
People: 21 2,205 4,725 6,930
Equipment: 3,600 4,060 7,660
Lighting: 2770 9,446 9,446
Ductwork: 0 2,183 7,961 10,144
Infiltration: Winter CFM:48, Summer CFM: 0 1,323 0 0 0
Ventilation: Winter CFM:201, Summer CFM:201 5,522 7,448 3,313 10,761
AED Excursion: 0 0 2,269 2,269
Total Building Load Totals: 39,020 15,436 71,559 86,995
Check Figures
Total Building Supply CFM: 3,103 CFM Per Square ft.: 0.901
Square ft. of Room Area: 3,442 Square ft. Per Ton: 475
Volume(ft3)of Cond. Space: 34,429
Building Loads
Total Heating Required Including Ventilation Air: 39,020 Btuh 39.020 MBH
Total Sensible Gain: 71,559 Btuh 82 %
Total Latent Gain: 15,436 Btuh 18 %
Total Cooling Required Including Ventilation Air. 86,995 Btuh 7.25 Tons(Based On Sensible+Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26, 2013, 1:29 PM
Rhvac-Residential S Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 16 Page 5
FB-uilding Pie Chart
Floor 8% Ventilation 14%
Roof 8%
Infiltration 3%
� xy
M
r
Building
Loss
Wall 20%
39,020
Btuh
Glass 46%
Roof 6% ED Excursion 3%
Wall 9% Ventilation 12%
"��r� gid•v
Nu
Ductwork 12%
Building
Gain
86,995
Btuh
Glass 31%
Lighting 11%
Equipment 9%
People 8%
EA...\13199 Palmisano RESIDENCE.rhv Thursday, September 26,2013, 1:29 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 Page 6
System 1 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg,, Sys
No Name SF Btuh CFMSize Vel Btuh Btuh CFM CFM
—Zone 1-
6 3 Living- 435 4,603 60 3-6 590 7,648 630 348 348
7 Bath 1 54 494 6 1-6 123 530 0 24 24
16 3 Dining 285 1,917 25 3-6 442 5,726 1,230 260 260
17 5 Kitchen 160 1,939 25 2-6 552 4,767 705 217 217
18 Pantry/Wine 64 730 9 1-6 236 1,021 0 46 46
19 Mud 64 543 7 1-6 222 958 0 44 44
20 2 221 2,913 38 2-6 608 5,249 105 239 239
Dance/media/offic
e
21 –Lower Reception 207 2,958 38 3-6 604 7,827 0 356 356
Ventilation 2,390 1,434 3,224
Duct Latent 2,183
System 1 total 1,490 18,487 209 35,159 8,077 1,533 1,533
System 1 Main Trunk Size: 22x12 in.
Velocity: 836 ft./min
Loss per 100 ft.: 0.089 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible - Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 3.60 81%/19% 35,159 8,077 43,236
Actual: 4.00 48,000
Equipment Data
Heating System Cooling System
Type: Electric Resistance Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency: 0% 0 SEER
Sound:
Capacity: 0 48000
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26, 2013, 1:29 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Loucks Engineering Inc. Palmisano Residence
Fort Lauderdale,FL 33309 Page 7
System 2 Room Load Summa
Htg Min, Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No 'Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
--Zone 1-
1 22 Master 416 3,760 49 4-6 494 8,539 210 388 388
Bedroom
2 20 Master Closet 130 1,037 13 1-6 181 783 0 36 36
3 21 Master Bath 176 2,024 26 1-6 522 2,254 600 102 102
4 14 Bedroom 1 186 1,556 20 2-6 369 3,183 405 145 145
5 15 Bath 1 49 206 3 1-6 196 849 105 39 39
8 12 Bath 2 80 438 6 1-6 263 1,137 105 52 52
9 21 Closet 2 49 60 1 1-6 105 454 0 21 21
10 11 Closet 3 49 60 1 1-6 105 454 0 21 21
11 14 Bedroom 2 221 2,587 34 2-6 516 4,454 405 202 202
12 10 Bedroom 3 221 2,637 34 2-6 510 4,401 705 200 200
13 17 hall 105 129 2 1-6 294 1,268 0 58 58
14 18 Laundry 63 77 1 1-6 253 1,093 600 50 50
15 –Upper Reception 207 2,830 37 3-6 436 5,655 0 257 257
Ventilation 3,131 1,879 4,224
System 2 total 1,952 20,532 226 36,400 7,359 1,570 1,570
System 2 Main Trunk Size: 22x12 in. _
Velocity: 856 ft./min
Loss per 100 ft.: 0.093 in.wg
Coolin System Summary
Cooling;, Sensible(Latent, Sensible Latent. Total
Tons Split Btuh Btuh Btuh
Net Required: 3.65 83%/17% 36,400 7,359 43,759
Actual: 4.00 48,000
Equipment Data
Heating System Cooling System
Type: Electric Resistance Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency: 0% 0 SEER
Sound:
Capacity: 0 0
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
E:\...\13199 Palmisano RESIDENCE.rhv Thursday, September 26, 2013, 1:29 PM
i
r
-` APR-
rill,
Rril12014
��� � M,i.�mrsf�oresYillage t _
Inc. Bur7c�rng Department
items NE T, Avenue:
z
11�'liarrri, 3313$
S
.71 t
Re.palrtt_16h ROSIdenti 1033 i��9�.Streei Miai�.Shores,FL 33138'
8aildlhg,Plarr Reviewer
Please agept this Mr as t egpst#ior a i:ownsltion 4nl_ permit scY that
we rnay het Srled�h 'ade`beams.
Cour current perrYut.process-4 i K-14 349
we are'currently a ressively"pursu!�rgthe�b,uiiling perrnit but Would
liTie to galn sone trrrre_ for the hr�me bwner5 as they have,asked for an
pdssrbllites that may be avi'lable for a sooner tYroVe in elate
Your cos�deacion and professrdnal advrce is mos#appreeta#e�:` r
"
Thank°you
�t �? r fw
si-21
ncerely �n •�`' �
A r
Ahth
Pa
ony-1 on
Oj
re ant,
A.
a
16950 5W 9b Avenue. #CGO-6435.4 OFFICE:'305 X59 9598 WEB wwrw.parspnsgrcom
F'almtto E3ay.FL 331. 7 FAK:;'305 'rKJ33 E�AIC:irlto(4parsansgCcom'
t'
Bobby Murphy
Project Manager- D AP:D
MOBILE: 4:0
rmurphy@parsonsgc.com
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-224176 Permit Number: RC-2-14-349
Scheduled Inspection Date: December 12,2014 Permit Type: Residential Construction
Inspector: Rodriguez,Jorge Inspection Type: Framing
Owner: PALMISANO, INGRID&ERIC Work Classification: New
Job Address:1035 NE 96 Street
Miami Shores, FL Phone Number
Parcel Number 1132060143730
Project: <NONE>
Contractor: PARSONS GENERAL CONTRACTORS,INC. Phone: (305)281-3480
Building Department Comments
NEW GROUND UP 2 STORY SINGLE FAMILY Infractlo Passed Comments
RESIDENCE INSPECTOR COMMENTS False
NSI�► Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-223956. EXTERIOR FRAMING
INSPECTION
11-26-14
Failed Not as per engineer recomendations.
v � 6 Ar-7 .
Correction
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
December 11,2014 For Inspections please call: (305)762-4949 Page 9 of 30
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-224236 Permit Number: RC-2-14-349
Scheduled Inspection Date: December 12,2014 Permit Type: Residential Construction
Inspector: Rodriguez,Jorge
Inspection Type: Insulation
Owner: PALMISANO, INGRID&ERIC Work Classification: New
Job Address:1035 NE 96 Street
Miami Shores,FL Phone Number
Parcel Number 1132060143730
Project: <NONE>
Contractor: PARSONS GENERAL CONTRACTORS,INC. Phone: (305)281-3480
Building Department Comments
NEW GROUND UP 2 STORY SINGLE FAMILY Infractio Passed Comments
RESIDENCE INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-224165. CREATED AS
REINSPECTION FOR INSP-207755. BY PROJECT MANAGER BOBBY
INSULATION INSPECTION FOR THE 2ND FLOOR
Failed ❑ Framing denied
Must pass framing
Correction P ��' � WA S 0A.)
Needed
Re-Inspection
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
December 11,2014 For Inspections please call: (305)762-4949 Page 10 of 30
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-223955 Permit Number: RC-2-14-349
Scheduled Inspection Date: December 12,2014 Permit Type: Residential Construction
Inspector: Rodriguez,Jorge Inspection Type: Truss Insp
Owner: PALMISANO, INGRID&ERIC Work Classification: New
Job Address:1035 NE 96 Street
Miami Shores,FL Phone Number
Parcel Number 1132060143730
Project: <NONE>
Contractor: PARSONS GENERAL CONTRACTORS,INC. Phone: (305)281-3480
Building Department Comments
NEW GROUND UP 2 STORY SINGLE FAMILY Infractio Passed Comments
RESIDENCE INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-223469. CREATED AS
REINSPECTION FOR INSP-223395. CREATED AS REINSPECTION FOR
INSP-207735.
Failed ❑ Fusses Denied. I. Naranjo
1.Need to revise the plans to reflect the changes made to detail 1/S-5
Missing strong back on all 2nd floor trusses.
Missing 1 bolt on the wood ledger detail 16/S-5
Correction IZ4. missing several bracings on the roof trusses. contractor to check all
Needed a t sses for the required bracing.
Missing sections of the bottom chord bracing.
Truss DG2 was place inverted as a result W4 does not fall on top of the
supporting wall. Provide repair detail and certification from the truss
Re-Inspection ❑ manufacturer engineer.
Fee -7 Missing supports(hangers)on corner jacks.
No Additional Inspections can be scheduled until
re-inspection fee is paid.
December 11,2014 For Inspections please call: (305)762-4949 Page 7 of 30