Loading...
RC-15-1499 (2) OFFICE COPY Permit Holder 6� 11VIgAlf &1aj'*'q-v0,f3 , Permit # �.- F.B.0 `violation Gam` Address u Date ' By Building Official Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores,FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-251743 Permit Number: RC-6-15-1499 Scheduled Inspection Date: January 28,2016 Permit Type: Residential Construction Inspector: Naranjo, Ismael Inspection Type: Miscellaneous Owner: WICHMANN,ANGELA KELSEY Work Classification: Addition/Alteration Job Address:1399 NE 104 Street Miami Shores, FL Phone Number (954)444-2156 Parcel Number 1122320320040 Project: <NONE> Contractor: ULTIMATE ENVIRONMENTS INC Phone: (561)998-3643 Building Department Comments KITCHEN AND BATH REMODEL NEW FRONT DOOR infractio Passed Comments AND A ADDITION OF A 1/2 BATH WITHIN THE EXACT INSPECTOR COMMENTS False SQUARE FOOTAGE OF THE HOME Inspector Comments Passed drywall put up with out passing rough inspection from electrical Failed Correction ❑ Needed Re-Inspection Fee �� J No Additional Inspections can be scheduled until re-inspection fee is paid January 27,2016 For Inspections please call: (305)762-4949 Page 19 of 23 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores,FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-251743 Permit Number: RC-6-15-1499 Scheduled Inspection Date: January 28,2016 Permit Type: Residential Construction Inspector: Naranjo, Ismael Inspection Type: Miscellaneous Owner: WICHMANN,ANGELA KELSEY Work Classification: Addition/Alteration Job Address:1399 NE 104 Street Miami Shores, FL Phone Number (954)444-2156 Parcel Number 1122320320040 Project: <NONE> Contractor: ULTIMATE ENVIRONMENTS INC Phone: (561)998-3643 Building Department Comments KITCHEN AND BATH REMODEL NEW FRONT DOOR Infractio Passed comments AND A ADDITION OF A 1/2 BATH WITHIN THE EXACT INSPECTOR COMMENTS False SQUARE FOOTAGE OF THE HOME Inspector Comments Passed ❑ drywall put up with out passing rough inspection from electrical Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid January 27,2016 For Inspections please call: (305)762-4949 Page 19 of 23 Jan 2516 11:56a Ultimate Environments 5616721452 p.2 CERTIFICATE OF LIABILITY INSURANCE DATE(RNMIDDfYYYY) 1/8/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING iNSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemertt(s). PRODUCER CON Favi Cobert CBIZ Weekes b Callaway PNONE (561)900-1639 FAX (561]900-1939 3945 West Atlantic Avenue E-MAIL AIC No: fcebert@cbizwc.com Delray Beach FL 334.45-3902 INSURER(Sl AFFORDING COVERAGE NAIL# INSURED INSURER Ca ltol Specialtv 10328 DINSURERe;Owners Insurance Co. 2700 Ultimate aniINSURERCFr CCI Insurance Co. 0178 1742 Costa ell Sol Environments, , Inc. INSURERD:Scottsdale Insurance Corp 41297 Boca Raton FJ;, 33432 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER:CL161707594 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN lS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDMONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ]NSR TYPEOFINSURANCE POLpCY EFF POS TR POUCYNUMBER Y LIMITS GENERAL LIABILITY X W/AMERCIAL GENERAL LIABILITY ' EACH OCCUR R£UCE $ 1,000,000 A CLAIAS-MADE a]CCCUR X X CT20160793ol 1/10/2016 1/10/2017 UfMAUf--TO PR - $ 50,000 MED EXP( one erson) $ 5,000 X BLPJZXET ADD'L INSURED X BLANIa3T WAIVER OF S[JSaZO. PERSONAL&ADV INJURY $ 1,000,000 GENERA:AGGREGATE S 2,000,000 GENLAGGREIMIT PRO- PER: PRODUCTS-CCMP1pPAGG S. 2,000,000 POLICY X, �a LOC AUTOMOBILE LIABILITY EMPLOYEESENEFWS-L416. S 11000,000 COMBINED SING--E LIMI X ANY AL?O L . I 1 000 OOO B ALLOYJtVE7 SCHEDULEC BODILY IVJURY(�erparson) S AUTOS AUTOS X X 0-236998-00 1/10/2016 1(10/2017 BODILY INJURY(�eraccidertt) $ X HIRE"AUTOS X AUTO D PROPERTY DAMAG= Per is nil $ NI UMBRELLA LLAB $ X ' OCCUR D X EXCESS LIAR .CLAIMS-MADE EACH OCCURRENCE S 2,000,000 �D X AGGREGATE $ 2,000,000 RETENTIONS 473400 0660 1/10/2016 1/10/2017 C YIIORKERSCOMPENSATION S ANYOPROPRIETOR/FAR-NELIABILITY R�EG(T,E YIN 4/01/2015 4/01/2016R lA'C STATU- OTH- OFFICERlMEMSER EXCLUDED? E.LEAGIACCIDENT s 11000,000 (Alamfatory in NH) If es,de5crte under EL DISEASE.EA EMPLOYE S 1 00O 000 DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT I S 1.000.000 DESCRIPTION OFOPERATIONSi]LOCATIONS rVEHICLES(AnschACOR0101,AdtfILIO+]alRemarksSClledule,Kmorespaceisrequired) CG# CGC1510696 Florida statute requir®s 10 day notice of cancellationfor non-payment of premium and 45 day notice for non-reAewai. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE VALL BE DELIVERED IN Miami Shores V1S1age ACCORDANCE WITH THE POLICY PROVISIONS, Building Department CG# CGC1510686 AUTHORIZED REPRESENTATIVE 10050 NE 2nd Ave Miami Shores, FL 33138 Leon A. Weekes/MSAUER ACORD 25(2010/05) INS025 r7ntmrti nti ®1988-2010 ACORD CORPORATION. All rights reserved. Tha Lr•.AR777 n�.na�n.i rnnn vrn rnnrernraet morlre of Ar•11A11 INSPECTION RECORD POST ON SITE Permit NO. RC-6-15-1499 Miami Shores Village Canstruction o. yu�ei 10050 N.E.2nd Avenue \ Miami Shores,FL 33138-0000 ", Phone: (305)795-2204 Fax: (305)756-8972 rio Issue Date. 12/8/2015 Expires:06!051 01 INSPECTION REQUESTS: (305)762-4949 or Log on at https://bidg.miamishoresvillage.com/cap REQUESTS ARE ACCEPTED DURING 8:30AM-3:30PM FOR THE FOLLOWING BUSINESS DAY. Requests must be received by 3 pm for following day inspections. Residential Construction Parcel #:1122320320040 Owner's Name:ANGELA KELSEY WICHMANN Owner's Phone: (954)444-2156 Job Address: 1399 NE 104 Street Total Square Feet: 00 Miami Shores_ FL Bond Number: 2924 Total Job Valuation: $ 63,823.41 WORK IS ALLOWED MONDAY THROUGH SATURDAY, 7:30AM-6:0012M.NO WORK IS ALLOWED ON Contractor(s) Phone Primary Contractor SUNDAY OR HOLIDAYS. ULTIMATE ENVIRONMENTS INC (561)998-3643 Yes BUILDING INSPECTIONS ARE DONE MONDAY THROUGH THURSDAY. ROOFING INSPECTIONS ARE DONE MONDAY THROUGH FRIDAY. NO BUILDING INSPECTIONS DONE ON FRIDAY. NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS THE PERMIT APPLICANTS RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. e S Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305)795.2204 Fax: (305) 756.8972 NOTICE OF VIOLATION DATE: January 28, 2016 TO: Angela Kelsey Wichmann 1399 NE 104 St. Miami Shores, FL 33138-2661 RE: Residence 1399 NE 104 St. Miami Shores, FL 33138-2661 PERMIT NO. RC-6-15-1499 FOLIO: 11-22320320040 Legal Description: River Bay Park ADDN. PB 40-72, Lot 4 BLK 3 YOU ARE HEREBY NOTIFIED that a STOP WORK ORDER has been issued to this property as an inspection of the above premises revealed that you have violated the provisions of the Florida Building Code which have been adopted as the uniform building code for Miami Shores Village, Florida or provisions of the Code of Miami-Dade County. Type of Violation: Building, Electrical, Mechanical, and Plumbing. Chapter: 1 Section:110.1 of: 2010 Florida Building Code To witt: Failure to pass required inspections and working in a manner contrary to the approved plans. REQUIREMENTS FOR CORRECTION ➢ Schedule a meeting with the Building Official. The architect of record,property owner, and contractors shall be present. ➢ Revise plans to reflect full extend of the work to be performed, including but not limited to electrical,mechanical,plumbing, structural and architectural. ➢ Provide a revise job cost estimate. Therefore,you are hereby directed that on or before Monday, February 22, 2015 you are to correct said VIOLATION and NOTIFY THE UNDERSIGNED BUILDING INSPECTOR that the VIOLATION has been corrected. Failure to make the correction(s) may result in one or more of the following actions: Disconnect utilities services, issuance of a ticket(s) in the amount of$500.00 or more, filing of a civil suit or criminal charges against you or initiation of an unsafe structures case requiring demolition of the structure. Also, failure to comply with this notice may result in the department withholding issuance of other permits to you, referral of this matter to the appropriate licensing board or the filing of a lien against your property in the amount of any unpaid ticketing fines. In accordance with the provisions of Section 8-17 of the Code of Miami-Dade County, you are also responsible for the reasonable costs and expenses incurred by the Building Official in enforcing the provisions of the Building Code. In the event further clarification or assistance is required,please contact Ismael Naranjo, B.O at(305) 795-2204 between the hours of 8:30 A.M. and 5:00 PM. Except in the case of life-safety hazards, you may be granted upon request an extension of time up to 90 days to correct the violation provided your request is submitted prior to the expiration of this Notice of Violation and enforcement costs incurred by the department to date are paid in full. To request an extension,please contact the Building Department by telephone at(305) 795-2207 or by e-mail to naranjoi ,miamishoresvilla eg_com. Thank you f r yo co peration in this matter. alt$. Ismael Nar �o, .O Building Director. Mail By: t1 1� Date Mailed: I Posted By: Return Receipttllel� Date Posted: CC: David C. Habeck N I• • • • • • • e^e Ie - I e - • Lru Ln n Ln - . to �� amx- P • [ r i� k f� i; �"t.� y �( r� S. � � Ln ItS� � Z» t, ,�`bz �;za ,J CO cc Y Q' Postage $ CO Postage $ CO Certified Fee M Certified Fee Postmark C7 Postmark QReturn Receipt Fee Here C3C7 rssmReturReceipt Fee Here C3 (Endorsement Required) (Endorsement Required) Restricted Delivery Fee Restricted Delivery Fee O (Endorsement Required) C7 (Endorsement Required) =I- Total Postage&Fees $ Total Postage&Fees C] rq Sent To r-3 Bern J�`Ct-elf -1---------- ioN f T C3 - ------� ----------- O 34reeet Apo No.; C�1 Imo- or PO Boz No. r- orPOBozNo. . 'A----------- 1 - VL 1 2' ' -- C�------------- Btate.g a�,®i g CL.. '3 3 32 , smte.zt 11neyerse for n lio . ^11 • ,� Property Search Application-Miami-Dade County Page 1 of 8 Address Owner Name Folio SEARCH: 1399 NE 104 St Suite Q PROPERTY INFORMATION Folio:11-2232-032-0040 Sub-Division: RIVER BAY PARK ADDN Property Address 1399 NE 104 ST Miami Shores,FL 33138-2661 Owner ANGELA KELSEY WICHMANN Mailing Address 1399 NE 104 ST MIAMI SHORES, FL 33138-2661 Primary Zone 1300 SGL FAMILY-2801-3000 SQ Primary Land Use 0101 RESIDENTIAL-SINGLE FAMILY: 1 UNIT Beds/Baths/Half 313/0 Floors 1 Living Units 1 Actual Area 3,494 Sq.Ft http://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application - Miami-Dade County Page 2 of 8 Living Area 2,701 Sq.Ft Adjusted Area 3,075 Sq.Ft Lot Size 8,925 Sq.Ft Year Built 1956 y ,� Layers r r ! x i t .Pmt t + C RI i ro 201 Featured Online Tools Comparable Sales Glossary Non-Ad Valorem Assessments PA Additional Online Tools Property Record Cards Property Search Help http://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application- Miami-Dade County Page 3 of 8 Property Taxes Report Discrepancies Report Homestead Fraud Tax Comparison Tax Estimator TRIM Notice Value Adjustment Board ASSESSMENT INFORMATION Year 2015 2014 2013 Land Value $312,324 $294,208 $267,396 Building Value $273,982 $269,924 $271,953 Extra Feature Value $7,109 $7,207 $7,306 Market Value $593,415 $571,339 $546,655 Assessed Value $494,064 $490,143 $482,900 TAXABLE VALUE INFORMATION 2015 2014 2013 COUNTY Exemption Value $50,000 $50,000 $50,000 Taxable Value $444,064 $440,143 $432,900 SCHOOL BOARD Exemption Value $25,000 $25,000 $25,000 Taxable Value $469,064 $465,143 $457,900 CITY Exemption Value $50,000 $50,000 $50,000 Taxable Value $444,064 $440,143 $432,900 REGIONAL Exemption Value $50,000 $50,000 $50,000 Taxable Value $444,064 $440,143 $432,900 BENEFITS INFORMATION Benefit Type 2015 2014 2013 Save Our Homes Cap Assessment Reduction $99,351 $81,196 $63,755 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Board,City,Regional). http://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application-Miami-Dade County Page 4 of 8 FULL LEGAL DESCRIPTION 32 52 42 RIVER BAY PARK ADDN PB 40-72 LOT 4 BLK 3 LOT SIZE 75.000 X 119 OR 14793-21881190 4 COC 25913-3847 08 2007 5 SALES INFORMATION Previous Sale Price OR Book-Page Qualification Description 08/01/2007 $0 25913-3847 Sales which are disqualified as a result of examination of the deed 08/01/2004 $780,000 22566-1123 Sales which are qualified 11/01/1990 $0 14793-2188 Sales which are disqualified as a result of examination of the deed For more information about the Department of Revenue's Sales Qualification Codes. 2015 2014 2013 LAND INFORMATION Land Use Muni Zone PA Zone Unit Type Units Calc Value GENERAL R-22.5,R-23 1300-SGL FAMILY-2801-3000 SQ Front Ft. 75.00 $312,324 BUILDING INFORMATION Building Number Sub Area Year Built Actual Sq.Ft Living Sq.Ft Adj Sq.Ft Calc Value 1 1 1956 3,494 2,701 3,075 $273,982 Building Sketches Available! EXTRA FEATURES Description Year Built Units Calc Value Wood Fence 1986 50 $444 Dock-Concrete Griders on Concrete Pilings 1984 288 $6,221 Patio-Wood Deck 1984 176 $444 ADDITIONAL INFORMATION h4://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application-Miami-Dade County Page 5 of 8 •The information listed below is not derived from the Property Appraiser's Office records.It is provided for convenience and is derived from other government agencies. LAND USE AND RESTRICTIONS Community Development District: NONE Community Redevelopment Area: NONE Empowerment Zone: NONE Enterprise Zone: NONE Urban Development: INSIDE URBAN DEVELOPMENT BOUNDARY Zoning Code: R22.5- Existing Land Use: 10-SINGLE-FAMILY,MED.-DENSITY(2-5 DU/GROSS ACRE). Government Agencies and Community Services OTHER GOVERNMENTAL JURISDICTIONS Business Incentives Childrens Trust City of Miami Shores Environmental Considerations Florida Department Of Revenue Florida Inland Navigation District Miami-Dade County Bulletin Board Non-Ad Valorem Assessments School Board South Florida Water Mgmt District Tax Collector The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp For inquiries and suggestions email us at http://www.miamidade.gov/PAPortaVContactForm/ContactFormMain.aspx. Version:2.0.3 EXEMPTIONS 6 BENEFITS Deployed Military h4://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application-Miami-Dade County Page 6 of 8 Disability Exemptions Homestead Institutional Senior Citizens More> REAL ESTATE 40 Yr Building Re-Certification Appealing Your Assessment Defective Drywall Folio Numbers Mortgage Fraud More> TANGIBLE PERSONAL PROPERTY Appealing your Assessment Assessment Information Search Exemptions Extension Requests Filing Returns More> http://www.miamidade.gov/propertysearch/ 1/28/2016 Property Search Application- Miami-Dade County Page 7 of 8 PUBLIC RECORDS Address Blocking Change of Name Change of Address Change of Ownership&Title Declaration of Condominium More> ONLINE TOOLS Property Search Property Sales Tax Estimator Tax Comparison Homestead Exemption and Portability More> TAX ROLL ADMINISTRATION Appealing your Assessment Reports h4://www.miamidade.gov/propertysearch/ 1/28/2016 � R4 c Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305)795.2204 Fax: (305)756.8972 NOTICE OF VIOLATION DATE: January 28, 2016 TO: Angela Kelsey Wichmann 1399 NE 104 St. Miami Shores, FL 33138-2661 RE: Residence 1399 NE 104 St. Miami Shores, FL 33138-2661 PERMIT NO. RC-6-15-1499 FOLIO: 11-22320320040 Legal Description: River Bay Park ADDN. PB 40-72, Lot 4 BLK 3 YOU ARE HEREBY NOTIFIED that a STOP WORK ORDER has been issued to this property as an inspection of the above premises revealed that you have violated the provisions of the Florida Building Code which have been adopted as the uniform building code for Miami Shores Village,Florida or provisions of the Code of Miami-Dade County. Type of Violation: Building, Electrical, Mechanical, and Plumbing. Chapter: 1 Section:110.1 of: 2010 Florida Building Code To wilt: Failure to pass required inspections and working in a manner contrary to the approved plans. 4 ,* t REQUIREMENTS FOR CORRECTION ➢ Schedule a meeting with the Building Official. The architect of record,property owner, and contractors shall be present. ➢ Revise plans to reflect full extend of the work to be performed, including but not limited to electrical,mechanical,plumbing, structural and architectural. A Provide a revise job cost estimate. Therefore, you are hereby directed that on or before Monday, February 22, 2015 you are to correct said VIOLATION and NOTIFY THE UNDERSIGNED BUILDING INSPECTOR that the VIOLATION has been corrected. Failure to make the correction(s) may result in one or more of the following actions: Disconnect utilities services, issuance of a ticket(s) in the amount of$500.00 or more, filing of a civil suit or criminal charges against you or initiation of an unsafe structures case requiring demolition of the structure. Also, failure to comply with this notice may result in the department withholding issuance of other permits to you,referral of this matter to the appropriate licensing board or the filing of a lien against your property in the amount of any unpaid ticketing fines. In accordance with the provisions of Section 8-17 of the Code of Miami-Dade County, you are also responsible for the reasonable costs and expenses incurred by the Building Official in enforcing the provisions of the Building Code. In the event further clarification or assistance is required,please contact Ismael Naranjo, B.O at(305) 795-2204 between the hours of 8:30 A.M. and 5:00 PM. Except in the case of life-safety hazards, you may be granted upon request an extension of time up to 90 days to correct the violation provided your request is submitted prior to the expiration of this Notice of Violation and enforcement costs incurred by the department to date are paid in full. To request an extension,please contact the Building Department by telephone at(305) 795-2207 or by e-mail to naranjoi@miamishoresvillage.com. Thank you fo o cooperation in this matter. �2Zz, t(, Ismael Naranjo, B.� Building Director. Mail By: _ I��tt►llt'�ft� Date Mailed: Posted By: Return Receipt umb r: _ Date Posted: 10 ( l V OU ,0 S�l CC: David C. Habeck _1 T� g..aBly `'G1 E US POSTAGE calm :_t /tcvt �_ .. fag - 1OOSO N.E.2NO AVENUE r 1 r "� { $066.739 y `h.D�gp1'y F L 0 33138 D A Ffrst-Cfa;S 1 Mailed From 33138 1,. t 7011 0470 0000 8985 5515 01/29/2016p3g6061800478 ANGELA WICHMANN 1399 NE 104 ST MIAMI SHO--- � NTLXIE 33'9 CE I ���21�e/�� RETURN TO SENDER uaNCLpaaMED UNABLE TO FORWARD BC: 333.36238299 *0806-05545 -29-42 :.�� - �i� �'�i1�6�I�I�li�osiisa�ii'�o1�i11���t11j1191�111�6IBg�°ello�llllll I COMPLETE .N COMPLETE THIS SECTIONON DELIVERY ■ Complete Items 1,2,and 3.Also complete A Signature Item 4 If Restricted Delivery is desired. 0 Agent ■ Print your name and address on the reverse X ❑Addressee so that we can return the card to you. B. Received by(PrintedName) C. Date of Delivery ■ Attach this card to the back of the mailpiece, or on the front if space permits. D. Is delivery address different from Item 1? ❑Yes 1. Article Addressed to: If YES,enter delivery address below: ❑No �t3�.� �►Gl-tlYl ASN I 3. Service type Certified Mall ❑Express Mail Registered 4%Rstum Receipt ❑Insured Mail ❑C.O.D. 4. Restricted Delivery?(Extra Fee) 13 es 2. Article;Number 7 011 0470 0000 8985 5 515 (Tianslerfiom ser- I PS Form 3811,February 2004 Domestic Return Receipt 102596-02-M-1540 I I I UNITED STATES POSTAL SERVICE First-Class Mail Postage&Fees Paid USPS I Permit No.G-10 I • Sir name, address, and ZIP+4 in this box• MIAMI SHORES VILLAGE BUILDING DEPARTMENT 10050 ME 2 AVENUE � MIAMI SHORES, FL 33135 I I I I I I I � I i r ,� SfATI'6 --- �� P Miami Shores VillageZJUN. L I `® '`� 1 20 P� Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 BUILDING Master Permit No. 9 PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL []PLUMBING F-1 MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP S�� CONTRACTOR DRAWINGS JOB ADDRESS: 131"t WE f0 I-(* -- re )r City: Miami Shores County: Miami Dade Zip• 33 l 3y folio/Parcel#: I -?.Z 3 2 -0 3Z -00 4 O IS the Building Historically Designated:Yes NO X OccupancyType: �-3 Load: Construction Type: Flood Zone: BFE: FFE: r �l,vggr�A V OWNER:Name(FeeSimple Titleholder)- /`�k�/� t�,cX,�phone#: �?� c/�i�, Z/� 60 • Address:_ I3`t`I ME: Id (P' I h City: .rte. State: F Zip: 3313�? Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: U I-E=»A-t- .€-W 1:r , Phone#: TW 99 g' 3COt4 3 Address: I ? City: State: FC. Zip: 33t37- Qualifier 3t3Z-Qualifier Name: Phone#: 1*6(-`(8 r"KO 33 A State Certification or Registration#: cxrr, K 10 f08(0 Certificate of Competency#: !r- DESIGNER:Architect/Engineer: c)A.0 Acz Phone#: SCt- 3`'l L- %0- Address: {J%-j 60LAr kx',U^. QA � City: &u4-U-1 -State: '?- Zip: S3Y 3 Z (value-of Work for this Perm- / Fqu4re/Linear Footage of�Work: - 7- Type of Work: b Addition Alteration ❑ New ❑ Repair/Replace r�❑ Demolition � Description of Work:_ [ . _!� � "�-- .� �-�- i�w✓ , e.��• r Specify color of color thru tile: Submittal Fee$".On Permit Fee$ CCF$ CO/CC 5- Scanning Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ gQ1Z> M TOTAL FEE NOW DL C?E-33 G- J (Revised02/24/2014) _ a Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Z(p Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OW N E R or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of A- 20 1 a _,by day of -A)^R ,, ,20 5 by pagadr, ,who is personally knmwo r�V.� Hqb—CCK ,who is personally known to me or who has produced as me or who has produced QI- ��V�T�- _ as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBL i '�- 7 , Sign: Sign: Print: IAV U r, Print: 3 Lk k4k30 Seal: =M*M:j2 Seal: " JEENA NELSON s MY COMMISSION#FFOS3780 A� EXPIRES:Sepwoba I S,2017 Bmdo Tin aP rte. APPROVED BY Pians Examiner Zoning S Structural Review Clerk (Revised02/24/2014) � 0 ,•�. p... Miami shores Village �nmm Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LICENCES B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 j Certificate must specify-the description of operations or contractor license number. ............................................................■.............................I BUSINESS NAME: UL'7 -1 lel 4LM C Ny l C���I� N �j BUSINESS ADDRESS:I 24Z COS L CITY BOC A �®ATATE�FL ZIP BUSINESS PHONE: ( l ) `%43-, FAX NUMBER Fk( ) 9 q3— (eq CELL PHONE � ( ) 99�;-Zto�)3 QUALIFIER'S NAME: C)-Ay (x) 14A8ez-'h QUALIFIER'S LIC NUMBER: CC is I c2G� ®)G 41940 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 �� NORTH MONROE STREET TALLAHASSEE FL 32399-0783 HABECK, DAVID CHRISTIAN ULTIMATE ENVIRONMENTS INC 1742 COSTA DEL SOL BOCA RATON FL 33432 Congratulations! With this license you become one of the nearly - - one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range a:'' o STATE OF FLORIDA from architects to yacht brokers,from boxers to barbeque restaurants, DEPARTMENT OF BUSINESS AND and they keep Florida's economy strong. PROFESSIONAL REGULATION Every day we work to improve the way we do business in order to CGC1510686 ISSUED: 08/24/2014 serve you better. For information about our services,please log onto www.myfloridalicanse.com. There you can find more information CERTIFIED GENERAL CONTRACTOR about our divisions and the regulations that impact you,subscribe HABECK, DAVID CHRISTIAN to department newsletters and learn more about the Departments ULTIMATE ENVIRONMENTS INC Initiatives. Our mission at the Department is:License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, IS CERTIFIED under the provisions of Ch.489 FS. and congratulations on your new license! Expiration date:AUG 31,2016 L1408240OM99 DETACH HERE RICK SCOTT, GOVERNOR KEN LAWSON,SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD <� ^ CGC1510686 The GENERAL CONTRACTOR �s g Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 qJL.,.- W. HABECK, DAVID CHRISTIANULTIMATE ENVIRONMENTS INC 1742 COSTA DEL SOL BOCA RATON FL 33432 ISSUED: 0824/2014 DISPLAY AS REQUIRED BY LAW SEQ# L1408240003599 NNE �s AN N d N P.O.Box 3353,West Palm Beach,FL 33402-3353 *''LOCATED AT" _ _. CONSTITUTIONAL TAX COLLECTOR www.pbctax.com Tel:(561)355-2264 1742 COSTA DEL SOL Seming Palm Bench County BOCA BATON, FL 33432 Sewing you. TYPE OF BUSINESS OWNER CERTIFICATION# RECEIPT#/DATE PAID AMT PAID BILL# 23.0051 GENERAL CONTRACTOR HASECK DAVID CGC1510M 615.78808-09130114 $27.50 840133061 This document is valid only when receipted by the Tax Collector's Office. STATE OF FLORIDA PALM BEACH COUNTY B3-439 2014/2015 LOCAL BUSINESS TAX RECEIPT ULTIMATE ENVIRONMENTS INC LBTR Number: 200711016 ULTIMATE ENVIRONMENTS INC EXPIRES: SEPTEMBER 30, 2015 620 EDDY ST BOCA RATON, FL 33487-1749 This receipt grants the privilege of engaging in or managing any business profession or occupation within its jurisdiction and MUST be conspicuously displayed at the place of business and in such a manner as to be open to the view of the public. ACO® DATE(MM/DD/YYYY) 16.� CERTIFICATE OF LIABILITY INSURANCE 6/4/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER NA VCT Fani Cebert CBIZ Weekes & Callaway PHONE (561)900-1639 FAC (561)900-1939 3945 West Atlantic Avenue —IL .fCQbert@cbi.ZWC.com ESS INSURER(S) AFFORDING COVERAGE NAIC# Delray Beach FL 33445-3902 INSURERAKinsale Insurance Company 38920 INSURED tNSURER B Owners Insurance Co. 32700 Ultimate Environments, Inc. INSURERC:FCCI Insurance Co. 10178 1742 Costa Del Sol INSURER D: INSURER E: Boca Raton FL 33432 INSURER F: COVERAGES CERTIFICATE NUMBER-CL1531606511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LLTR TYPE OF INSURANCE POLICY EFF POLICY EXP POLICY NUMBER M/D LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY DAAT R NTE PREMIE Ea occurrence) $ 100,000 A CLAIMS-MADE ❑X OCCUR X X 01000259650 1/10/2015 1/10/2016 MED EXP(Any one person) $ 10,000 X BLANKET ADD IL INSURED PERSONAL&ADV INJURY $ 1,000,000 X BLANKET WAIVER OF SUBRO. GENERAL AGGREGATE $ 2,000,000 GE N'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY X PRO- ircT LOC EMPLOYEE BENEFITS LIAB. $ 1,000,000 AUTOMOBILE LIABILITY EeeBI COMBINED SINGLE LIMIT 1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED X X 0-236998-00 1/10/2015 1/10/2016 BODILY INJURY(Per accident $ AUTOS AUT^OrS ) X HIRED AUTOS X AUTOS D PROPER d DAMAGE $ UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 2,000,000 A nXExcESS LUIB CLAIMS-MADE AGGREGATE $ 2,000,000 DED I X I RETENTION 1000259670 1/10/2015 1/10/2016 $ C WORKERS COMPENSATION X X WC STATU- X OTH- AND EMPLOYERS'LIABILITY I FIR ANY PROPRIETOR/PARTNER/EXECUTNE Y/N 73400 4/01/2015 4/01/2016 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? El N/A (Mandatory In NH) If yes,describe under L.DISEASE-EA EMPLOYEE $ 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS i LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,If more space Is required) CG# CGC1510686 Florida statute requires 10 day notice of cancellation for non-payment of premium and 45 day notice for non-renewal. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Miami Shores Village ACCORDANCE WITH THE POLICY PROVISIONS. Building Department AUTHORIZED REPRESENTATIVE CG# CGC1510686 10050 NE 2nd Ave Miami Shores, FL 33138 Leon A. Weekea/MSAUER ACORD 25(2010105) ©1988-2010 ACORD CORPORATION. All rights reserved. INS025 r7nimm n+ This Af.npn mama and Innn aro ranietaraA marine of Af:nRrf Angela Kelsey 1399 NE 1041'Street Miami Shores, Florida 33138 August 20,2015 Ismael Naranjo Building Official Miami Shores Village 10050 NE 2nd Avenue Miami Shores, Florida 33138 Re: 1399 NE 104 Street, Miami Shores, Florida 33138 Dear Mr. Naranjo: I am writing to you with respect to a pending building permit application for renovations to my residence as referenced above. I am unable to attend a meeting scheduled for Friday morning,August 21,2015 at your office to discuss certain issues that have been brought to my attention by my general contractor, David Habeck. I have authorized my husband, Michael Zealy,to act as my agent at the meeting. Because my home is in a flood zone,it is my understanding that improvements to my residence cannot exceed fifty percent of the value of the structure. In that regard, Florida Peninsula Insurance Company has issued a homeowners policy with a replacement value of$553,300.00. My flood insurance is with Allstate Insurance with a coverage limit for the structure in the amount of$250,000 (the maximum flood insurance available).Copies of these policies are available should you desire them incident to the application. My contemplated improvements are less than fifty percent of its replacement value as determined by my insurer. In the current real estate market,it is my view that the market value of the structure will likely exceed its replacement value. Please advise should you need further documentation to facilitate the issuance of a building permit. Thank you. Si rely, Ang la elsey f/k/a ngela Kelsey Wichmann ,_.. ANNE M. Cx A N N O N P.O.Box 3353,West Palm Beach,FL 33402-3353 **LOCATED AT" _4. CONSTITUTIONAL TAX COLLECTOR www.pbctax.com Tel:(561)355-2264 Seming Palm Beach County 1742 COSTA DEL SOL Serving you. BOCA RATON, FL 33432 TYPE OF BUSINESS OWNER CERTIFICATION# I RECEIPT#/DATE PAID AMT PAID BILL# 23-0051 GENERAL CONTRACTOR HABECK DAVID CGC1510886 1 815.901566-09M/15 $27.50 840130955 This document is valid only when receipted by the Tax Collector's Office. STATE OF FLORIDA PALM BEACH COUNTY B2-743 2015/2016 LOCAL BUSINESS TAX RECEIPT ULTIMATE ENVIRONMENTS INC LBTR Number: 200711016 ULTIMATE ENVIRONMENTS INC EXPIRES: SEPTEMBER 30, 2016 620 EDDY ST BOCA RATON, FL 33487-1749 This receipt grants the privilege of engaging in or uIIuIInIuIInIIuIonllln�IInIial�o managing any business profession or occupation within Its jurisdiction and MUST be conspicuously displayed at the place of business and in such a manner as to be open to the view of the public. LOCAL BUSINESS TAX THIS IS NOT A BILL RECEIPT# 16 00054027 CITY OF BOCA RATON Any changes in name,address, suite,ownership,ect.will BUSINESS TAX AUTHORITY require a new application 201 WEST PALMETTO PARK ROAD within 15 days to avoid BOCA RATON,FLA.33432-3795 penalty or the license is null ULTIMATE ENVIRONMENTS,INC. and void. HABECK,DAVID CHRISTIAN BUSINESS TAX.RECEIPT Business Tax fee: 105.00 1742 COSTA DEL SOL CERTIFICATE OF USE Penalty fee: .00 EXPIRE'S: 9/30/16 Late fee: .00 Additional fee: .00 ULTIMATE ENVIRONMENTS, INC. Transfer fee: .00 1742 COSTA DEL SOL Total paid: 105.00 BOCA RATON FL 33432 has paid the business tax at the above address for the period classification:CONTRACTOR,(OL)GENERAL beginning the'I st day of October and ending the 30th day of September to engage in the business,profession or occupation of: Comments: GENERAL C,OiNTRAC-TOR welcome to the City of Boca Raton. We are proud to have your business in our community. You may call us at 561-393-7937 if you have questions relating to your business needs.Office hours are 8:00 AM to 4:00 PM,except Wednesday the hours are 8:00 AM to 3:00 PM. Please verify all information on your Business Tax Receipt and notify us immediately if there is an error. ALL CHANGES REQUIRE A NEW APPLICATION.Visit our website at:WWW.MYBOCA.US, "Quicklink" to Business Tax to download applications and to verify business information. Applications must be submitted in person with apppropiate documentation and fee. If the business has closed or moved outside the City limits,you are required to notify the City in writing. Please post this'Business Tax Receipt"at the above location in a place where it may be seen at all times. A courtesy renewal notice will be sent 30 to 60 days prior to expiration. If you do not receive the renewal notice, you must still pay the tax on time.Late penalties will not be waived if you do not receive the notice.The Business Tax may be renewed in person, by drop-box within City Hall, by mail or*by using the website and click "online services"from the homepage.To renew online you will need your Business Tax receipt#and your"pin"#.These numbers will be provided on your renewal notice. We accept checks, cash, money order, Visa, MasterCard or American Exnress as a method of navmPnt r.herk mnct have RncinPac Tnv Pari-int if anti F,P malt,.noxiahla t„ti o U.S.DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE FEDERAL EA;FRGENCY MANAGEMENT AGENCY OMB No. 1660-0008 National Flood Insurance Program Important: Read the instructions on pages 1-9. Expiration Date:July 31,2015 SECTION A-PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name ANGELA KELSEY WICHMANN Policy Number. A2. Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Company MAIC Number. 1399 NW 104 ST City MIAMI SHORES State FL ZIP Code 33138 A3.`Property Description(Lot and Block Numbers,Tax Parcel Number,Legal Description,etc.) • RIVER-BAY PARK ADDITION 40-72 LOT 3 BLK 3 A4. Building Use(e.g.,Residential,Non-Residential,Addition,Accessory,etc.)Residential A5. Latitude/Longitude:Lat. 52 8712N Long.80.1693W Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A¢. Attach at least 2�Ratographs of the building if the Certificate is being used to obtain flood insurance. A?.*SwilAng Dia8&h Mumber Q •• At. For 3 buildIn&vp Ccrawlspace or mclosure(s): A9. For a building with an attached garage: of'Square foatage of crawlspace or enclosure(s) 2065 sq ft a) Square footage of attached garage 634 sq ft .10) Number of permanent"spsrrings in the crawispace b) Number of permanent flood openings in the attached garage •••••or enclosur@*J within 1.Q.fpo%pbove adjacent grade 8 within 1.0 foot above adjacent grade Be • •Total nelama of flood kppf8j in A8.b 91 sq in c) Total net area of flood openings in A9.b na sq in • •linginee id bpd openings . ❑ Yes ® No d) Engineered flood openings? ❑ Yes ® No :0000: •••SECTION B-FLOOD INSURANCE RATE MAP(FIRM)INFORMATION Comrrlj fib Name&0"manity Number B2.County Name B3.State VI�ItAGE OF MIAM164ORES.1206W MIAMI-DADE FL B4.Map/Panel'Nuraber B5.Suffix B6.FIRM Index Date B7.FIRM Panel B8.Flood B9.Base Flood Elevation(s)(Zone 12086CO306 L 9-11-09 Effective 1evised-09 Date Zone(s) AO,use basee flood depth) B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations-Zones Al A30,AE,AH,A(with BFE),VE,V1-V30,V(with BFE),AR,AR/A,AR/AE,AR/A1-A30,AR/AH,AR/AO.Complete Items C2.a-h below according to the building diagram specified in Item A7.In Puerto Rico only,enter meters. Benchmark Utilized:B.C.B.M. Vertical Datum: NAVD 29 Indicate elevation datum used for the elevations in items a)through h)below. 19 NGVD 1929 ❑NAVD 1988 ❑Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a)Top of bottom floor(including basement,crawlspace,or enclosure floor) 8.30 ®feet ❑meters b)Top of the next higher floor na. ❑feet ❑meters c) Bottom of the lowest horizontal structural member(V Zones only) na. ❑feet ❑meters d)Attached garage(top of slab) 4.88 ❑feet ❑meters e) Lowest elevation of machinery or equipment servicing the building 8.15 ®feet ❑meters (Describe type of equipment and location in Comments) f) Lowest adjacent(finished)grade next to building(LAG) 4.61 ®feet ❑meters g)Highest adjacent(finished)grade next to building(HAG) 5.5-2 ®feet ❑meters h)Lowest adjacent grade at lowest elevation of deck or stairs,including structural support na. ❑feet ❑meters SECTION D-SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation information.l certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code,Section 1001. ® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a ® Check here if attachments. licensed land surveyor? ® Yes ❑ No �/ � Certifier's Name Scott J Douglass License Number 4532 /1 l k 7 Title President Company Name Douglass Leavy&Associates Inc. Address 7914 Wiles Road City Coral Springs State FI ZIP Code 33067 Sitnature Date 7/13/15 Telephone 9543447994 FEMA Form 086-0-33(7/12) See reverse side for continuation. Replaces all previous editions. `6.b V C4 8 BA/t• 0 B® I"R-6 B d, tfuww b IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number. 1399 NW 104 STREET City MIAMI SHORES State FL ZIP Code 33138 Company MAIC Number. SECTION D—SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION(CONTINUED) Copy both sides of this Elevation Certificate for(1)community official,(2)insurance agent/company,and(3)building owner. Comments C2E.AC UNIT=8.15 Signature Date 713/15 (!Y LILDING CLI;17A,TION INFORMATION(SURVEY NOT REQUIRED)FOR ZONE AO AND ZONE A(WITHOUT BFE) 0.0000 410 0 For LQnes AO and without BFE:),tomoete Items E1—E5.If the Certificate is intended to support a LOMA or LOMR-F request,complete Sections A,B, and C.For Items E1"E4,use natditl"gMde,if available.Check the measurement used.In Puerto Rico only,enter meters. 4141•.•• 4 1000 E1.41 PLoAde elevation infbrmatior�r tA8 following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent 41 41 ppada(HAG)arMhe lowestgdgadit grade(LAG). af top of bo$8rp"gr(includtMftsement,crawlspace,or enclosure)is ❑feet ❑meters ❑above or❑below the HAG. 0 44140 of bottom f1bor(including besement,crawlspace,or enclosure)is ❑feet ❑meters ❑above or❑ below the LAG. E24 For Building Diggrams 6-9%*h pewntanent flood openings provided in Section A Items 8 and/or 9(seepages 8-9 of Instructions),the next higher floor 41:(@l6 fation Oft in the diagraw4;,pfJthe building is [:]feet ❑meters ❑above or ❑below the HAG. E3.41'Attached gafage•(!op of slats)iso. ❑feet ❑meters ❑above or ❑below the HAG. E4.0 npbf platf mpefOrnachinAwthd/q'(equipment servicing the building is ❑feet ❑meters ❑above or❑below the HAG. DODO E5. Zone AO onl f.41lf no flood depth number is available,is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑Yes ❑ No ❑ Unknown.The local official must certify this information in Section G. SECTION F—PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION The property owner or owner's authorized representative who completes Sections A,B,and E for Zone A(without a FEMA-issued or community-issued BFE) or Zone AO must sign here.The statements in Sections A,B,and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑Check here if attachments. SECTION G—COMMUNITY INFORMATION(OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A,B,C(or E),and G of this Elevation Certificate.Complete the applicable item(s)and sign below.Check the measurement used in Items G8—G10.In Puerto Rico only,enter meters. G1.❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,engineer,or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2.❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE)or Zone AO. G3.❑ The following information(Items G4—G10)is provided for community floodplain management purposes. G4.Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑New Construction ❑Substantial Improvement G8. Elevation of as-built lowest floor(including basement)of the building: ❑feet ❑meters Datum G9. BFE or(in Zone AO)depth of flooding at the building site: ❑feet ❑meters Datum G10.Community's design flood elevation: ❑feet ❑meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑Check here if attachments. FEMA Form 086-0-33(7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit,Suite,and/or Bldg.No.)or P.O. Route and Box No. Policy Number: 1399 NE 104 STREET City MIAMI SHORES State FL ZIP Code 33138 Company NAIC Number: If-using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View ; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. r • • .p ,rye ., ,' 4 w FEMA Form 086-0-33 (7/12) Replaces all previous editions. , V ' C t4,TX7 FD JUN 2015 FEMA 50% RULE - SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE SUBSTANTIAL IMPROVEMENT/DAMAGE Z101-0410 NOTICE TO PROPERTY OWNERS Rebuilding your Home after the storm? Adding on, renovating, or remodeling your home? Here's information YOU need to know about the "50% Rule" If your home or business is below the 100-year flood elevation, also known as the Base Flood Elevation (BFE), FEMA has flood damage prevention regulations that may affect how you remodel, renovate, or add on to your building. If your home or business sustained structural and/or interior damage, these regulations may affect how you rebuild. These laws are required by the National Flood Insurance Program to protect lives and investment from future flood damages. Miami Shores Village is required to adopt and enforce these laws in order for federally -backed flood insurance to be made available to we residents and property owners. SAVE YOURSELF TIME AND MONEY! PLEASE READ THE FOLLOWING INFORMATION: SUBSTANTIAL DAMAGE means damage of any origin sustained by a structure whereby the cost of restoring the structure to it's before damage condition would equal or exceed 50 percent of the market value or replacement cost of the structure before the damage occurred. (Note: The cost of the repairs must include all costs necessary to fully repair the structure to its "before damage" condition.) SUBSTANTIAL IMPROVEMENT means any reconstruction, rehabilitation, addition, or other improvement of a structure, the cost of which equals or exceeds 50 percent of the market value of the structure before the "start of construction" of the improvement. If a building is "substantially damaged" or "substantially improved", it must be brought into compliance with the flood damage prevention regulations, including elevating the building to or above the 100-year flood elevation. Miami Shores Village, follows the National Flood Insurance Program requirements, and has the responsibility to determine "substantial damage" and "substantial improvement", and has implemented the procedures on the following pages to do so. SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNERS Miami Shores Village will use the assessed value of your structure (excluding the land) recorded by the Property Appraiser's Office. If you disagree with the Property Appraiser's valuation of the structure, you may engage a property appraiser licensed by the State of Florida to submit a comparable property appraisal for the total market value of the structure. You must obtain and submit to the Building Department a detailed and complete cost estimate for the addition, remodeling, reconstruction or for repair of all the damages sustained by your home, prepared and signed by a licensed general contractor. The contractor must sign an affidavit indicating that the cost estimate submitted includes all damages or all improvements to your home, not just structural. The signed contract document must be submitted with your application. If the owner is acting st his ct her own contractor, the owner is responsible for submitting the cost estimate, and providing documentation, including subcontractor bids, to document the cost estimate. The Building Department will evaluate the cost of improvements or repairs and determine if they are fair and reasonable. For damage repairs, pre-storm prices and rates will be utilized. The cost of improvements or repairs does not include items not considered a permanent part of the structure. (i.e., plans, surveys, permits, sidewalks, pools, screens, sheds, gazebos, fences, etc. --see attached copy). If your home is determined to have"substantial damage"or is proposed to be"substantially improved", then an elevation certificate must be submitted to the Building Department to determine the lowest floor elevation. Garages and carports are not considered to be the"lowest floor'. If the lowest floor is below the 100-year flood elevation, the building must be elevated to the 100 year flood elevation, or above, that level. Likewise, all electrical and mechanical equipment(heating and cooling, etc.), bathrooms, and laundry rooms must be elevated to, or above, the 100-year flood level. Only parking, building access and limited, incidental storage is allowed below the flood level. Non- residential buildings may be"flood-proofed" instead of being elevated. If the lowest floor of the structure, including electrical and mechanical equipment and bathroom are already above the 100-year flood elevation, the building can be repaired and reconstructed without having to comply with the fifty percent(50%) rule. Building plans must be prepared to show how the building is to be elevated. If located in a V-zone, Coastal High Hazard Area, or if the building is to be flood-proofed, these plans must be prepare the Building Department. d and certified by a registered professional engineer or architect. Certificates for this purpose are available from IMPORTANT NOTE ON DONATED MATERIALS AND VOLUNTEER LABOR: The value placed on materials should be equal to the actual or estimated cost of all materials to be used. Where materials or servicing equipment are donated or discounted below normal market values, the value should be adjusted to an amount equivalent to that estimated through normal market transaction. Self or Volunteer Labor: The value placed on labor should be equal to the actual or estimated labor charge for repairs of all damages sustained the structure. Where non-reimbursed (volunteer) labor is involved, the value of the labor should be estimated based on applicable minimum hourly wage scales for the type of construction work to be completed. Our permitting official based on his/her professional judgment and knowledge of local/regional wage scales can provide additional guidance to determine reasonable labor rates for professional trades(i.e. electricians, plumbers, block masons, framing, HVAC). SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE ITEMS TO BE INCLUDED (Please check off each line) ALL STRUCTURAL ELEMENTS INCLUDING: [] Spread or continuous foundation footings and pilings [J Monolithic or other types of concrete slabs [] Bearing walls, tie beams and trusses []Wood or reinforced concrete decking or roofing [] Floors and ceilings []Attached decks and porches [] Interior partition walls j J Exterior wall finishes (e.g., brick, stucco or siding) including painting and decorative moldings [J Windows and doors [J Re-shingling or re-tiling a roof (]Hardware ALL INTERIOR FINISH ELEMENTS, INCLUDING: Tiling, linoleum, stone or carpet over sub-flooring [] Bathroom tiling and fixtures []Wall finishes (e.g., drywall, painting, stucco, plaster, paneling, marble or other decorative finishes) [] Kitchen, utility and bathroom cabinets j] Built-in bookcases, cabinets and furniture [] Hardware ALL UTILITY AND SERVICE EQUIPMENT, INCLUDING: [J HVAC equipment j] Repair or reconstruction of plumbing and electrical services [J Light fixtures and ceiling fans [] Security systems (J Built-in kitchen appliances [J Central vacuum systems []Water filtration, conditioning or recirculation systems ALSO: [J Labor and other costs associated with demolishing, removing or altering building components [J Overhead and profit ITEMS TO BE EXCLUDED Plans and specifications Surrey costs Permit fees Debris removal, (e.g., removal of debris from building or lot, dumpster rental, transport fees to landfill and landfill tipping fees), clean-up (e.g., dirt and mud removal, building dry out, etc.) Items'not considered real property such as: throw rugs (carpeting over finished floors), furniture, refrigerators, appliances which are not built-in, etc. OUTSIDE IMPROVEMENTS INCLUDING: Landscaping Sidewalks Fences Yard lights Swimming poolslspa Screened pool enclosures Sheds Gazebos Detached structures (incl. garages) Landscape irrigation systems Docks and Davits Seawalls Driveways Decks ITEMS REQUIRED TO EVALUATE YOUR APPLICATION APPLICANT MUST SUBMIT ALL OF THE FOLLOWING (please check off each item): 1. Completed and signed application for substantial damage/improvement review (included in this package). 2. Elevation certificate if property is located above base flood elevation. 3. Property Owner's Substantial Damage or Substantial Improvement Affidavit signed, notarized and dated (included in package). 4. Contractor's Substantial Damage or Substantial Improvement Affidavit signed, notarized and dated (included in package). 5. Estimated Cost of reconstruction/improvement form (included in package) and all required backup. Include subcontractor's bids and itemized cost lists (see footnote on Cost Estimate Form). 6. This checklist. 7. Copy of construction contract. If the owner is the contractor, submit all subcontractor bids to document the cost estimate. SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE APPLICATION FOR SUBSTANTIAL DAMAGE Property Address: OR SUBSTANTIAL IMPROVEMENT REVIEW 1 A)E 1041,- Prop rty `-Property Owner's Name. , FL 33t 3.3 Property wner's Address. ` 3 cl`i N 1F 104t' S�a � L 3-313J Property Owner's Phone Number. " - gfyy - 2,16- Contractor's Name. Contractor's Address: i:Z-1 LCL 33°( 32 Contractors Phone Number. 57.1.- x,951 - 3(.q3 Flood Zone BFE Lowest Floor Elevation (Excluding garage or carport) Check one of the following: [j I am attaching a State Certified Appraiser's report, valuing the structure at: I am not attaching a State Certified Appraiser's report and I accept the use of the valuation of m property that has been recorded by the County Property Appraiser's Office. SIGNATURES: Property Owner: Date: ZZ Contractor: Date: Of _ a SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE PROPERTY OWNER'S SUBSTANTIAL DAMAGE OR Property Address: SUBSTANTIAL IMPROVEMENT AFFIDAVIT Contractor's Name: 33132 Property Owner's Name. I I F Property ner's Addres : Property Owners Phone PC -3-3133 Number: lIT-q _ qL(L( 1 hereby attest that the list of work and cost estimate submitted with my Substantial Damage or Substantial Improvement Application reflects ALL OF THE WORK TO BE CONDUCTED on the subject structure including all additions, improvements and repairs and, if the work is the result of Substantial Damage, this work will return the structure at least to the"before damage"condition and bring the structure into compliance with all applicable codes. Neither I nor any subcontractor or agent will make any repairs or perform any work on the subject structure other than what has been included in the attached list. I UNDERSTAND THAT I AM SUBJECT TO ENFORCEMENT ACTION, WHICH MAY INCLUDE FINES, IF ANY INSPECTION OF THE PROPERTY REVEALS THAT I, OR MY CONTRACTOR, HAVE MADE REPAIRS OR IMPROVEMENTS NOT INCLUDED ON THE ATTACHED LIST OF REPAIRS OR THE APPROVED BUILDING PLANS. See attached itemized list. STATE OF -I ruc eq COUNTY OF Before me this day personally appeared �6-g who, being duly swom, deposes and says that he/she has rea , understands, and grees to comply with all the afo m tion d c nditiJA o s. ProOwner's Signature Sworn c and subscribed before me this day of A.,w%1 20 S. Notary Public State o My commission expires AV E B/RH PAY =WISSM 8 EE 207180 Ly,"M`'�I--June 29 2016 SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE CONTRACTOR'S SUBSTANTIAL DAMAGE OR Property Address: SUBSTANTIAL IMPROVEMENT AFFIDAVIT Contractor's Name: Contractor's Com anyNam Contractor's Address, Ccs 1z1 S� 1 Contractor's Phone Number: yet — 598' a 3(.41 Contractor's State Registration or Certification Number: US- 0 1?6 Contractor's We Registration Number(if applicable): I hereby attest that I, or a member of my staff, personally inspected the subject property and produced the attached itemized list of repairs, reconstruction and/or remodeling which are hereby submitted for a Substantial Damage or Substantial Improvement Review. The list of work contains ALL OF THE WORK TO BE CONDUCTED on the subject property. If the property sustained Substantial Damage, this list of Work, will return the structure to at least its condition prior to damage and bring the structure into compliance with all applicable codes. I further attest that all additions, improvements or repairs proposed for the subject building are included in this estimate and that neither I nor any subcontractor or agent representing me will make any repairs or perform any work on the subject structure other than what has been included in the attached list. I UNDERSTAND THAT I AM SUBJECT TO ENFORCEMENT ACTION, WHICH MAY INCLUDE FINES, IF ANY INSPECTION OF THE PROPERTY REVEALS THAT I, OR MY CONTRACTOR, HAVE MADE REPAIRS OR IMPROVEMENTS NOT INCLUDED ON THE ATTACHED LIST OF REPAIRS OR THE APPROVED BUILDING PLANS. See attached itemized list. STATE OF Por;8A COUNTY OF Palm f3e-&LK Before me this day personally appeared_ pav,& H >ec<, ,who, being duly sworn, deposes and says that he/she has read, understands, and agrees to comply with all the afor ed conditio 9 Contractor's Signature Sworn to and subscribed before me this d 20 I� vP&% Public tate of: JEENA NELSON commission expires: q-Is-I-r MY COMMISSION#FF053780 o,7d°` EXPIRES:Septwnbef 15,2017 Application Cost Estimate of Reconstruction / Improvement Number Date 6-ZZ - co,Z S" Address 1 � 33�3$ This cost estimate of reconstruction/Improvement must be prepared by and signed by the contractor or by the owner if the owner acts as the contractor. Owners who act as their own perform. contractors must estimate their labor cost at the current market value for any work they intend to Sub-Contractor Bids Contractor or Owner Materia Labor Costs Estimates_�7 .X17 L7 Costs C)37 Bid Amounts(see note "D") 1. Masonry 2. Carpentry Material (rough) 3. Carpentry Labor(rough) 4. Roofing 5. Insulation and Weather-strip 6. Exterior Finish (stucco) 7. Doors, Windows& Shutters 8. Lumber Finish 9. Hardware 10. Drywall 11. Cabinets(Built-in) 12. Floor Covering 13. Plumbing 14. Showerfrub/Toilet 15. Electrical& Light Fixtures 16. Concrete 17. Built-in Appliances 18. HVAC 19. Paint 20. Demolition& Removal 21. Overhead & Profit • /�-_ ENERGY PERFORMANCE LEVEL (EPL DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 73 0 The lower the EnergyPerformance Index,the more efficient the home. Ca 1399 NE 104th St, Miami, FL, 33128- I. 3128-1. New construction or existing Existing(Projects 9. Wall Types Insulation 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 937.20 ft2 b.NIA R= ft2 3. Number of units,if multiple family 1 c.WA R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=19.0 565.00 ft2 6. Conditioned floor area(ft2) 565 b.WA R= ft2 7. Windows" Description Area c.WA R= fe a. U-Factor. Sgl,U=0.94 68.40 ft2 11.a.S p:Attic,Ret:Attic,AH:Master Bedroom 6 113 SHGC: SHGC--0.50 b. U-Factor. WA ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 16.8 SEER:17.00 SHGC: d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 17.1 COP:1.00 Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.500 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 565.00 ft2 a• EF: b.N/A R= ft2 c.WA R= ft2 b. Conservation features 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building RBE Sr Construction through the above energy saving features which will be installed(or exceeded) tion - gAFo in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. fr++, �-• Builder Signature: Date: — a Address of New Home: City/FL Zip: c0D �c; wE *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EkW)jgcierltives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 orsee thl EtieygyGVi je,we6 site at energygauge.com for information and a list of certified Raters. For information about*Flq i*Puf dltg Egde, Energy Conservation,contact the Florida Building Commission's support staff. •• see e• • e e •• **Label req fired by Seation 303.1.3of the Florida Building Code, Energy Conservation,if not DEFAULT. •• • • • % • • •• • • • •• • • • • • • • • EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • t , FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Kelsey&Zealy Residence Builder Name: Street: 1399 NE 104th St Permit Office: City,State,Zip: Miami,FL,33128- Permit Number: Owner. Jurisdiction: 232400 Design Location: FL,Miami 1. New construction or existing Existing(Projects 9. Wall Types(937.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 937.20 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst Pse? No 10.Ceiling Types (565.0 sgfL) Insulation Area a.Under Attic(Vented) R=19.0 565.00 ft 6. Conditioned floor area above grade(ft2) 565 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(68.4 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Master Bedroom 6 113 a. U-Factor. Sgl,U=0.94 68.40 ft2 SHGC: SHGC=0.50 b. U-Factor. WA ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 16.8 SEER:17.00 c. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Strip Heat 17.1 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0,500 14.Hot water systems 8. Floor Types 565.0 sgft.) Insulation Area a. � ( EF:0.000 a.Slab-On-Grade Edge Insulation R=0.0 565.00 ft2 b. Conservation features b.N/A R= ft2 c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 25.24 PASS Total Standard Reference Loads: 34.40 1 hereby certify that the plans and specifications covered by Review of the plans and 'CKE S744' this calculation are in compliance with the Florida Energy specifications covered by this 40 = , 0�, Code. calculation indicates compliance with the Florida Energy Code. unrr ' °• ",1 O PREPARED BY: Before construction is completed 'Ise DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Cale. OD WE-1 OWNER/AGENT: BUILDING OFFICIAL: -_ _ DATE: _ DATE: _ -- . .. . . . . ... . - Compliance requlres•corripletiSn oT a•FiblMda Air Barrier and Insulation Inspection Checklist . . •.. . ... . . . . . . . • . • . .. . . . . . •. . . • .. . • .. . . . 5/19/20151:07 PIS ; . ; ;'; �-EnebipaggeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 z i PROJECT Title: Kelsey&Zealy Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 565 Lot# Owner: Total Stories: 1 Biock/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 1399 NE 104th St Permit Office: Cross Ventilation: County: Miami-Dade Jurisdiction: 232400 Whole House Fan: City,State,Zip: Miami, Family Type: Single-family FL, 33128- New/Exisdng: Existing(Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Miami FL_MIAMI_INTL AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Blockl 565 6215 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 565 6215 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Master Bedroom 96 ft 0 565 ft' 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel file 612 fta 0 fta Medium 0.96 No 0.9 No 1 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 r 565 fta N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 W*dergWo.(Vonted) . • •Vaster Bedroom 19 565 ft' 0.11 Wood • •• • • • • ••• • • ••. • ••. . • • • • • • • • • • • •• • • • • • •• • • • •• • • •. • • • 5/19/2015 1:07 PM • •: : : kne�auge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 r , WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below �l # Omt Ta_ Wall Type - - Spate R--Value Ft In Ft In Area R_Vahle Fraction Ahsnr grad • _ 1 N Exterior Concrete Block-Int InsMaster Bedro 4.1 14.6 11 160.6 fta 0 0.349999 0 _2 S Exterior Concrete Block-Int InsMaster Bedro 4.1 14.6 11 160.6 ftz 0 0.349999 0 3 E Exterior Concrete Block-Int InsMaster Bedro 4.1 56 11 616.0 ft2 0 0.349999 0 DOORS # Omt Door Type Space Storms U-Value Ft Width In FHeightln Area 1 N Wood Master Bedro None .46 3 6.8 20.4 f12 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single(Tinted) Yes 0.94 0.5 45.0 ft' 0 ft0 in 0 ft 0 in Drapes/blinds None 2 E 3 Metal Single(Tinted) Yes 0.94 0.5 5.4 fN 0 ft0 in 0 ft 0 in Drapes/blinds None 3 E 3 Metal Single(Tinted) Yes 0.94 0.5 18.0 ft' 0 ft0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 444.6 24.41 45.9 .207 4.2922 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block_Ducts 1 Electric Strip Heat None COP:1 17.06 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:17 16.8 kBtu/hr 504 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF ft' DUCTS -Supply- -Return- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 113 ftz Attic 28 ftp Default Leakage Master Bed (Default) (Default) 1 1 •• ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • •• • • • • • •• • • • •• • • •• • • • ••• • • • • ••• • • 5/19/2015 1:07 P.11. ••• o t: Ene"ge@ USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb [[ ]]Mar r [ ]May [X]Jun [�Jul Aug Se Oct [ Nov Dec HeatinJan Feb [X]Mar E AApr [ ]May E I Jun I I Jul AuI Sep [ ]Oct LX]Nov Dec Vantin Jan Feb [[[�1X11 Mar IXl A r [ 11 may )Jun [ l Jul [[[ 111 AugAu [ l Se [Xl OctOa [x]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 7$ 78 78 78 78 PM 78 78 78 78 78 78 78 7 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) PM 668 66 68 68 66 68 6688 66 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1-Electric Strip Heat 0% 1-Central Unit • ••• • •1• • • • • • • • • • • • • •• • • • • • •• • • • •• • • •• • • . 5/19/20151:07PPS9 • • Ene"v*ge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1399 NE 104th St PERMIT#: Miami, FL,33128- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283.Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system.Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. _^ Ducts 403.2.2 All ducts,air handlers,filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shalt not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers.Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to=R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds.Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78%(82%after 4/16/13). Heat pump pool heaters minimum COP=4.0. Coolingtheatin8• •� 403.6 Sijing calculation performed&attached. Minimum efficiencies per ••; ; ; ; ?tables 503.2.3. Equipment efficiency verification required.Special equipment*. ; ; ; ; ;• ompsion cooling or heating capacity requires separate system or Mable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/koeA wags gog2.1; ;R;1g space permitting. 0V 0:0 5/19/2015 1:07;IS90 ;•••; • fneipGe,ge®USA-FlaRes2010 Sedion 405.4.1 compliant Software Page 5 of 5 Building Input Summary Report PROJECT Title: Kelsey&Zealy Residence Bedrooms: 3 Address Type: Street Address Building Type: User Bathrooms: 0 Lot# Owner: Conditioned Area: 565 sq.ft. Block/SubDivision: #of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: 1399 NE 104th St Permit Office: Rotate Angle: 0 County: Miami-Dade Jurisdiction: 232400 Cross Ventilation: City,State,Zip: Miami, Family Type: Single-family Whole House Fan: FL, 33128- New/Existing: Existing(Projected) Terrain: Suburban Year Construct: 2015 Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 Low UTILITY RATES Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 0 0.09 Natural Gas Therm Florida Average 0 1.72 Fuel Oil Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS Number Name _ Area `Volume 1 Block1 565 6215 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 buster BH'dr&A ; ; ;56:i 6215 Yes 4 3 Yes Yes Yes 00 0*0 00 • 00 FLOORS # Floor Type Space Perimeter R-Value Area — _ Tile Wood Carpet 1 Slab-OwGrade:Edge Ir=suratiod MafteCB4dr4om 96 ft 0 565 ft' ___ 0 0 1 •• • • • • • •• • • 5/19/20151:07 PM EnergyGauge®/USRFSB v3.1 Page 1 of 5 Building Input Summary Report ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip - Barrel file 612 ft2 0 ft2 Medium 0.96 No 0.9 No 1 22.6 ATTIC # Type Ventilation Vent Ratio(1 In) Area RBS IRCC 1 Full attic Vented T 300 565 f12 N N CEILING # _Ceiling Type _ Space R-Value Area Framing Fraction Truss Type- - 1 Under Attic() Master Bedroom 19 565 ft2 0.11 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in"Project"section above. AdjacentCavity Width Height Sheathing Framing Solar Below # - Omt _ o Wall Type , _ _ Space R-Value Ft In Ft n Area R-Value Fraction Absor. Grade% 1 N Exterior Concrete Block-Int InsuMaster Bedroo 4.1 14.6 11 160.6 ft2 0 0.349999 0 2 S Exterior Concrete Block-Int InsuMaster Bedroo 4.1 14.6 11 160.6 ft2 0 0.349999 0 3 E Exterior Concrete Block-Int InsuMaster Bedroo 4.1 56 11 616.0 ft2 0 0.349999 0 DOORS Width Height # Omt Door Type Space Storms U-Value Ft In Ft In Area 1 N Wood Master Bedroo None .46 3 6.8 20.4 ft2 WINDOWS Wall Overhang # Omt ID Frame___Panes _ NFRC___ U-Factor_ SHG_C Storm Area Depth Separation Interlor Shade Screening 1 N 1 Metal Single(Tinted) Yes 0.94 0.5 N 45.0 ft2 0 ft0 in 0 ft 0 in Drapes/blinds None 2 E 3 Metal Single(Tinted) Yes 0.94 0.5 N 5.4 ft2 0 ft 0 in 0 ft0 in Drapes/blinds None 3 E 3 Metal Single(Tinted) Yes 0.94 0.5 N 18.0 ft2 0 ft0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s) 1 Wholehouse Best Guess .0003 444.6 24.41 45.9 .207 4.2922 All MASS Mass Type Area-------- Thickness FurnitureFraction Space ----------------------- -------- No Added 0 ft2 0 ft 0.3 Master Bedroom 5/19/2015 1:07 PM EnergyGauge®/USRFSB v3.1 Page 2 of 5 Building Input Summary Report APPLIANCES&LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans(Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 %Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.046 0.046 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 %Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 %Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 %Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 %Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 907 kWh/Yr Peak Value: 296 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 %Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 %Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 %Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 %Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 140 Watts Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 0.1 0.1 %Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts MECHANICAL VENTILATION Type Supply CFM Exhaust CFM HRV Fan Run Time Heating System Cooling System None 0 0 0 OW 0% 1-Electric Strip Heat 1-Central Unit CLOTHES WASHERS ID Type Screen Location Capacity Make Model Schedule LoadsPerYr 1 1 Main Default New Main 2.847 HERS201 (invalid) CLOTHES DRYERS ID Type__ _ Screen Location Capacity Fuel Type Make Model Schedule LoadsPerYr 1 Dry;j •;D f�t t favi • M aln Electricity • • • • • • • • • • • •• • • •• • • • 5/19/20151:07 PM EnergyGauge®/USRFSS v3.1 Page 4 of 5 • •• •• • • • •• •• Building Input Summary Report DISHWASHERS ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr 1 Dishwash Default New Main 12 2004 or N HERS201 372 RANGE OVEN ID Type Screen Location Type Fueltype Make Model Cooktop Oven 1 Ranges Default New Main CooktopOven C Electric Electric FI Not Conv HARD WIRED LIGHTING ID Type Screen Location Total# Qualify# Comp FI All Other FL bctBuibtype Schedule Watts per bulb 1 Hard-Wir By Count-Qualif Main 100 10 0 10 2 Hard-Wir Default New Exterior 3 Hard-Wir Default New Garage MISC ELECTRICAL LOADS ID Type Screen Item Quantity Category Operating Location Schedule Off Standby 1 Misc Elec Simple Default 1 1 Main HERS201 1 • •• • • •• • • • 5/19/20151:07 PM EnergyGauge®/USRFSB Al Page 5 of 5 ••• • • • • ••• • • ••• • • • ••• • • . Air System Sizing Summary for AHU-1 Project Name:Kelsey Residence 05/18/201 Prepared by:JAO Arch 07:37AN Air System Information Air System Name ......................................... AHU-1 Number of zones .......................................................... 1 Equipment Class .................................... SPILT AHU Floor Area ............................................................. 666.0 ft' Air System Type .......................................... SZCAV Location .......................................... Miami IAP,Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ................... Sum of space airflow rates Calculation Months ....................................... Jan to Dec Space CFM ............... Individual peak space loads Sizing Data .................................................. Calculated Central Cooling Coil Sizing Data Total coil load ..................................................... 1.8 Tons Load occurs at ................................................ Jun 1600 Total coil load ................................................... 16.8 MBH OA DB/WB .................................................. 89.7/76.9 OF Sensible coil load ............................................. 12.8 MBH Entering DB/WB .......................................... 76.3/66.5 OF Coil CFM at Jun 1600 ........................................ 818 CFM Leaving DB/WB ........................................... 55.9163.6 OF Max block CFM ................................................. 818 CFM Coil ADP ................................................................. 62.5 OF Sum of peak zone CFM ..................................... 818 CFM Bypass Factor ....................................................... 0.100 Sensibleheat ratio .......................................... 1.000 Resulting RH .............................................................. 51 % ft2/Ton ............................................................ 319.7 Design supply temp. ................................................ 53.0 OF BTU/(hr-ft2) ....................................................... 37.5 Zone T-stat Check ............................................... 1 of 1 OK Water flow @ 10.0 OF rise .................................. NIA Max zone temperature deviation ............................... 0.0 OF Central Heating Coil Sizing Data Max coil load .................................................... 12.7 MBH Load occurs at ................................................. Des Htg CoilCFM at Des Htg ......................................... 818 CFM BTU/(hr-ft2) .............................................................. 22.4 Max coil CFM .................................................... 818 CFM Ent.DB/Lvg DB ........................................... 69.4182.2 OF Water flow @ 20.0 OF drop ................................ N/A Supply Fan Sizing Data Actual max CFM ................................................ 818 CFM Fan motor BHP ....................................................... 0.13 BHP Standard CFM ................................................... 817 CFM Fan motor kW ......................................................... 0.10 kW Actual max CFM/ft2 ........................................... 1 A4 CFM/ft2 Fan static ................................................................ 0.60 in wg Outdoor Ventilation Air Data Design airflow CFM ............................................... 0 CFM CFM/person ............................................................ 0.00 CFM/person CFM/ft2 ............................................................. 0.0 s • • • • • • • • • • •• • • • • • •• • • • •• • • •• • • • • • • • • • • • • • •• •• •••• •• 400 •• •••• ••• •• • Hourly Analysis Program v4.70 Page 1 of 1 ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence DATE: 8/242015 1399 NE 104 Street,Mkord Shores,FL 33138 8lan4va Date Remove Flooring and Base at Location of New Entry and Powder $ 371.25 7.5 $ 49.50 Remove Ceiling Drywall only(framing to remain) $ 24.75 0.5 $ 49.50 Remove Existing Interior Wells and Drywall(framing to remain) $ 198.00 4 $ 49.50 Remove Existing Entry Door and Window $ 396.00 8 $ 49.50 C. Remove Existing Window Sill(to allow fw new entry) $ 396.00 8 $ 49.50 TY rim►a� ' ���� k - Infip Existing Entry Door - $ 396.00 8 $ 49.50 Finish Exterior To Match Adjacent Stucco Finish $ 396.00 8 $ 49.50 Materials $ 150.00 1 $ 150.00 .__, amfs%�oosur __ 94200C 0; Patch and Repair Existing Walls due to Demolition $ 198.00 4 $ 49.50 Frame,Hang,and Finish New Wens $ 792.00 16 $ 49.50 Hang,and Finish Ceiling $ 198.00 4 $ 49.50 Materials $ 73700 1 $ 737.00 F'a -o _ IL ivy Floor Prep $ 49.50 1 $ 49.50 Install Tne Flooring at New Powder $ 106.43 46 $ 2.37 Install Wan Tile at Powder Rowe South Wan $ 232.38 65 $ 3.58 Install Wall Tile at Covered Porch Entry $ 250.25 70 $ 3.58 Materials $ 44143 1 $ 441.43 Prime Ceiling&Wens $ 59.40 360 $ 0.17 ••• •••••• •••••• Paint Ceding&Walls $ 118.80 360 $ 0.33 •• • • • • Paint Doors(Powder) $ 49.50 1 $ 49.50 *so*** 00 • ••i••• •• Paint&Materials $ 110.00 1 $ 110.00 •••••• 0 0 "W.top o6go Install Countertop at Sink and MC Return $ 247.50 5 $ 49.50 •••••• •••••• i•••• Materials ,_ _- _ $ 297.00 1 $ 297.00 •••• ••••• Conder 7 SaBtotaJ __Y 544&0s ••••••� •••• •EMrbtr Cps'ar��ds dew& '�"' �`�� .�� • • • •••••� Instar Entry Door and Side Windows Assembly $ 1,782.00 36 $ 49.50 • •• •••• Materials $ 3344.00 1 $ 3,344.00 •••••• •••••• Install Ceiling Light Fidures and Switches $ 264.00 3 $ 88.00 • • •••••• •••••• Install New GFCI Outlets at Powder(2) $ 176.00 2 $ 88.00 • • • • :Goes: Install New Outlets per code(2) $ 176.00 2 $ 88.00 •• • •• :•: Install New Toilet Fan and Switch $ 176.00 2 $ 88.00 •• • Relocate Existing Outlets(2)to Adjacent Wens at New Location of Entry $ 176.00 2 $ 88.00 Install New GFCI Outlets at Covered Porch(2) $ 176.00 2 $ 88.00 Replace existing Calling Light with Surface Mounted one at Covered Porde $ 88.00 1 $ 88.00 Materials $ 61794_ 1 $ 617.94 i,. Install New water Supply arW Drain Unes for Toilet and vanity $ 748.00 8 $ 93.50 Install New Toilet $ 187.00 2 $ 93.50 Install Faucet and Vanity Sink $ 187.00 2 $ 93.50 Materials $ 1,300.20 1 $ 1,300.20 � �f>�izlit�dtmtat $v, z4TL2R:i Install New Wood Base $ 49.50 1 $ 49.50 Install New Vanity Cabinet $ 99.00 2 $ 49.50 Install Door and Hardware(Powder) $ 198.00 4 $ 49.50 Install Powder Room Accessories $ 49.50 1 $ 49.50 Materials $ 1,599.62 1 $ 1,599.62 EftyToW rt $ „17,808.84' Kelsey Zeaiy Residence DATE: 824/2015 1399 NE 104 Street Mtemi Shores FL 33138 LVA Iftn-OW Dale Reprove ExlsBng Flowing $ 1,980.00 40 $ 49.50 Remove Existing Baseboard $ 398.00 8 $ 49.50 Remove Existing Decorative Fire Place $ 396.00 8 $ 49.50 Remove Existingtier by Dtrting room_ $ 396.00 8 $ 49.50 Patch and Repair Endsffng Wens and Ceilings due to Demolition $ 792.00 16 $ 49.50 Materials $ 290.40 1 $ 290.40 (�IrItIpD'` Prime Ceiling&Wens $ 340.73 2065 $ 0.17 Paint Ceiling&Wens $ 681.45 2065 $ 0.33 Paint&Materials $ _ 572.00 1 $ 572.00 $ 1, 41E Floor Prep $ 1,188.00 24 $ 49.50 Install Flowing(foe) $ 2,762.32 1168 $ 2.37 Materials(Allowance) $ 1,071.95 1 $ 1,071.95 - ` b Install New Wood Base $ 396.00 8 $ 49.50 Materials $ 326.70 1 $ 326.70 tbrrpertl+yStifitm�al JBroarn Foil $ -TT 589,b5'_. ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence DATE: 8242015 1399 NE 104 Street,Miami Shores,FL 33138 Ol*Q d e• • - Tdtai Coat e. ',:`r% pti06rL t>emolitlon sign-OW Daft Remove Existing Flooring at Bathroom,Closet and Study $ 495.00 10 $ 49.50 Remove F)ds*tg Portion of Ceifmg for New Attic Access $ 49.50 1 $ 49.50 Remove Existing Interior Partition per Plans $ 445.50 9 $ 49.50 Remove Existing Pl unbing Fbdures and Pipes $ 99.00 2 $ 49.50 Remove Doors and Frames per Plans $ 198.00 4 $ 49.50 Remove Existing Wag Finishes at Study $ 99.00 2 $ 49.50 Remove Any Damaged Gyp.Bd.After the Removal of Wag Finish $ 74.25 1.5 $ 49.50 Remove Existing Vanity Cabinet _$__ 24.75 0.5 $ 49.50 z �ramhrglpryyratl � Patch and Repair Existing Wags/Gaffing due to Demolition $ 99.00 2 $ 49.50 Frame,Hang and Finish New Wags $ 1,386.00 28 $ 49.50 Materials $ - 693.00 1 $ 693.00 ... ;_2.';r . . fte Srd#da1 , mfv [Ftooring(Walif T11e� Floor Prep $ 247.50 5 $ 49.50 Install New Wood Flooring at Closets and Halfway $ 323.40 140 $ 2.31 Install Master Bathroom Floor(file) $ 331.10 140 $ 2.37 Install Shower Pan(Tile) $ 330.00 1 $ 330.00 Install Wag Tile(Shaver and 4'up on all Bathroom Walls) $ 1,108.25 310 $ 3.58 Install Transitional Strips between Wood and Tile Flooring $ 99.00 2 $ 49.50 Materials $ 3,060.75 1 $ 3,060.75 rano $n the St -V -$ 'g 00 •••• Prime Ceiling&Walls $ 145.20 880 $ 0.17 ••• •••• •••••• Paint Caging&Wags $ 290.40 880 $ 0.33 •• • • •• • Paint&Materials $ _ 242.00 1 $ 242.00 •••••• • • • •• _ - --- r Pe+ $ 1 $ 877.80 • •••• •••••• �Catrtter Top i' ��i%� •••••• • • • Install Countertop(Sink) $ 198.00 4 $ 49.50 •••• •••• 660900 Materials $ 1,350.00_ 1 $ 1,350.00 • pp .. -- CamtarT'op c 1.500' •••• $ 48. • •0000• • • •••••• ••0•• • • •••••• Install Recessed Gelling Light Fbdures and Switches $ 704.00 8 $ 88.00 • Install Surface Mounted Light Fbdures and Switches $ 264.00 3 $ 88.00 •• •• •••••• •• •••••• Install Wall Sconces and Switch $ 176.00 2 $ 88.00 •••••• • Install New GFCI Outlets $ 176.00 2 $ 88.00 • • • • • Install New Outlets per code(5) $ 264.00 3 $ 88.00 • • :000% •••••• Install New Toilet Fan and Switch $ 176.00 2 $ 88.00 • • • Install New 50 AMP Wire and Outlet for Water Heater $ 352.00 4 $ 88.00 • • • • • • •••• • • Install New Power for AC System $ 352.00 4 $ 88.00 •• • • ••• • • Materials $ 1,807.17 1 $ 1,807.17 • • • 00 0 AM XT_i Install Pre-Fab Concrete Slab for Condenser Unit $ 88.00 1 $ 88.00 Install Condenser Unit $ 704.00 8 $ 88.00 Install Air Handler Unit $ 704.00 8 $ 88.00 Install New Ductwork and Diffusers $ 1,408.00 18 $ 88.00 Install Refrigerant Piping and Condensate Drain $ 2,024.00 23 $ 88.00 Materials $ 6,284.25 1 $ 6,284.25 kl - - - f Pium6tli9__r.� . ACS#bW $ ,11,212.25,E Move/Relocate Water and Drain Lines to New Location of Plumbing Fixtures $ 2,150.50 23 $ 93.50 Install New Toilet $ 93.50 1 $ 93.50 Install Faucets and Vanity Sinks $ 187.00 2 $ 93.50 Install New Shower Manifold,Trim and Shower Head $ 374.00 4 $ 93.50 Install New Hand Held Shower Head for New Tub $ 374.00 4 $ 93.50 Install New Soaking Tub $ 187.00 2 $ 93.50 Materials _. _._ $ 5568.94 1 $ 5,568.94 Install New Vanity Cabinets $ 198.00 4 $ 49.50 Install New Mirrors $ 99.00 2 $ 49.50 Install Master Bathroom Accessories $ 198.00 4 $ 49.50 Install New Shower Door and Glass $ 198.00 4 $ 49.50 Install New Closet Doors(2) $ 198.00 4 $ 49.50 Install Closet Shelving,Cabinets,Rods and Hardware $ 792.00 16 $ 49.50 Install New Ladder for Attic Access $ 198.00 4 $ 49.50 Materials $ 9,727.52 1 $ 9,727.52 CVPW*}r$pbl W 8 `11 xk52] YLTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 stlCJoToml; _ . _ 47,416.4$,;! Kelsey Zealy Residence DATE: 8/24!2015 1399 NE 104 MiarN FL 33138 tp ark - ; ofy. .of Remove Existing Appliances,Sink,and Drain Lhres $ 198.00 4 $ 49.50 Remove EAsWV Counter Tops and CaNdnets $ 594.00 12 $ 49.50 Remove Trim artd Mokpr _ $ _ 4950 1 $ 49.50 Patch and Repair Existing Walls/Ceft due to arty existing damages $ 198.00 4 $ 49.50 Materials $ 8600 1 $ 66.00 FiBG $ 284 Qd'i Prime Calling&Walls $ 88.00 400 $ 0.17 Paint Cemng&Webs $ 132.00 400 $ 0.33 Paint&Materials _ $ 121.00 1 $ 121.00 1 InsiallfSeal Backsplash $ 183.15 45 $ 4.07 Install Countertops $ 594.00 12 $ 49.50 Materials $ 5,269.00 1 $ 5,269.00 n49aderT-� Ott 1$'i Instaii Garbage Disposes $ 187.00 2 $ 93.50 Instep New Water Line to Stearn Oven $ 187.00 2 $ 93.50 Install Drain and Water Supply Livres $ 280.50 3 $ 93.50 •••• Instep Faucet and Sink Drain $ 187.00 2 $ 93.50 • • • • Install Undennount Sink $ 187.00 2 $ 93.50 • • • •••• •••••• Matertais $ 1,074.40 1 $ 1,074.40 •• • • •• • `_.92 M .__ �_.Fu` _ ';PJ9% ad mw til-maw 9••••• • • • •• • 0000 0000•• Install Base,and Wap •0900•Cabinets $ 1,138.50 23 $ 49.50 • • Install Baseboard $ 49.50 1 $ 49.50 Go** •••• •••••i Materials $ 16,c3�8e1.20 1 $ 18,381.20 • 9 • • • 0 -_ y ;c '" v '.. 1: 5t91ji 900• 909• °� � :_�- .. � •999• Kl1CJarte efYAt, - . _ _ $. _ 142.RS� 0000•• 0000 • • • • 0 •999• •• •• 9990 Kelsey Zealy Residence .••.9 9 1399 NE 104 Street,Munni StaNes,FL 33138 •• • • •• gr u). .�" ,.���.3*R T",. c s�__-.__ _ e > .� ti „t;x�-. • •9909• •0999• Supervision $ 4,510.00 1 $ 4,510.00 • • Trash Rarnoval and Dump Fees $ 1,850.00 1 $ 1,850.00 •9•• • •• ••• • •9• General Cleaning and Prep $ 1,089.00 1 $ 1,089.00 • • • • •• . MateM and Labor Transport $ 4,224.00 1 $ 4,224.00 •• • Insrsarxre $ 1,168.00 1 $ 1,188.00 s"aroonpo-es.T Awovali_► 7 12 83s� s 9 • ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Street,Miami Stores,FL 33138 a 11 ,.ToUaj ,Pte.` Anti Fracture Membrane(Allowance) $ 38.50 50 $ 0.77 Floor Tile Powder Room(Allowance) $ 82.50 50 $ 1.65 Wad Tile Powder Room(Allowance) $ 142.56 72 $ 1.98 Wad Tde Covered Porch EntryTravertUre to Match Porch Floor(Allowance) $ 177.87 77 $ 2.31 - - - "< ;,�Floorlrft YJatart9i 5rrb T $ -W 441.43, Counter Top Material and Fabrication(Allowance) $ 297.00 1 $ 297.00 . ..*. .._ T GoprderTop Spb TOW 600w Single pole Dimmer(Allowance) $ 24.20 1 $ 24.20 Single Pole Lighted Switch(Allowance) $ 2.75 1 $ 2.75 15 Amp GFCI(Allowance) $ 55.40 4 $ 13.85 15-Amp Outlet and Cover Piste(Allowance) $ 7.59 3 $ 2.53 Exhaust Fan(Allowance) $ 110.00 1 $ 110.00 Powder Recessed Can Light(Allowance) $ 220.00 4 $ 55.00 Covered Porch COMM Mounted Light(Allowance) $ 99.00 1 $ 99.00 Misc.Electrical Materials -- :- -_ _ $--_-99.00 1 $ 99.00 St T_claw$ 817.9AJ hiumbl��e3e�►u aid; %... _. � . ..- Vanity Sink(Allowance) $ 242.00 1 $ 242.00 Bathroom Sink Faucet(Allowance) $ 198.00 1 $ 198.00 ••••• Faucet Supply Livres $ 13.68 2 $ 6.64 ••• ••••• •••••• Faucet Supply Valves $ 14.67 2 $ 7.34 •• Toilet White(Allowance) $ 385.00 1 $ 385.00 • i •••• '60 0000•• • Toilet Supply Lines $ 8.84 1 $ 8.84 •••• Mist Plumbing Materials $ 440.00 1 $ 440.00 •••i•• •••••• _ 71_atgria a Vfib Totet.$---1 3W2 •••• i••••i _ • • 0000 • �tTbigB _ ` `" _ _ 0000 0000.• • Door and Hardware(Allowance) $ 385.00 1 $ 385.00 ••••• 00:90: Wood Base Board(Allowance) $ 49.50 25 $ 1.96 :00* *0:00• Vanily Cabinet 5'-5"(Allowance) $ 1,087.00 1 $ 1,087.00 •• •• •••• Powder Room Accessories:Paper Holder(Allowance) $ 50.60 1 $ 50.60 00000 008000 • • Powder Room AawssoflesTowel Ring(Allowance) $ 47.52 1 $ 47.52 • • • • • 0AII-WO-9Gb-tc#a! $ .::=1, 9.8 : • • • • *see** • 000.9• Kelsey Zealy Residence • 9 9 • 9 1399 NE 104 Street Miami ShoresFL 33138 • • • ••• •• •• ." • ,® o o• eW u � .'_ T Cwt,.',:-.' � �; •••e j • It}Tningit]+ritMasE�r BBf1fQ0r11_ $ k Anil Fracture Membrane(Allowance)f $ 989.45 1285 $ 0.77 Floor Tile(Allowance) _ $ 82.50 50 $ 1.65 t Wood Base 328.70_ 165 $ 1.98 PLTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores,FL 33138 'F(oodngAdateria/DemU_ _ - � .1 -' Anti Fracture Membrane(Allowance) $ 234.85 305 $ 0.77 Master Bathroom Floor Tile(Allowance) $ 287.98 154 $ 1.87 Tub Wali Tile(Allowance) $ 224.40 80 $ 2.81 Shower Wall Tile(Allowance) $ 953.70 340 $ 2.81 Shower Pan Tile Flooring Mosaic(Allowance) $ 309.76 16 $ 19.36 Wood Flooring Plank(Allowance) $ 830.06 154 $ 5.39 Glue $ 154.00 1 $ 154.00 Transitional Strips(Allowance) $ 66.00 6 $ 11.00 ;Ftooring_Mater�t Sub 7iDtal $' ,' (1H0Z$. Counter Top DelaU Counter Top Material and Fabrication(Atiowance) - $_----1,350.00 1 $ 1,350.00 txunterTopSutiTotal $ 1,350,00 �lsealce►MaEstlalsDeiaA "_^ 600w Single pole Dimmer(Allowance) $ 72.60 3 $ 24.20 Single Pole Lighted Switch(Allowance) $ 13.75 5 $ 2.75 15 Amp GFCI(Allowance) $ 27.70 2 $ 13.85 15-Amp Outlet and Cover Plate(Allowance) $ 10.12 4 $ 2.53 Exhaust Fan(Allowance) $ 110.00 1 $ 110.00 4"Recessed Can Light(Allowance) $ 550.00 10 $ 55.00 LED Surface Mounted Light at Closet(Allowance) $ 306.00 4 $ 77.00 Electric Water Heater(Allowance) $ 495.00 1 $ 495.00 6666 Misc.Electrical Materials _ $_ 220.00 1 $ 220.00 • • Bectrkai_ii feAals Sub T4W_ _1 807.17>,+, • ••s *age 00 •••••• ACsDatatl_ -- r s • • • • 1.5 Tons 17 Seer Trane Unit(Air Handler GAM5BOA18yCondensing unit 4TTX6018) $ 5,861.00 1 $ 5,881.00 ••• •• ***a •••4 i• Misc.AC Materials $ _ 403.25 1 $ 403.25 •••••• „ .,. - AG ter(als SWb`TOfal $ *@ 28gt `{ •••• i s••s P/umb►ngAsa�edels Demes ••••• • • • • 6666 Vanity Sink(Allowance) � � $ 195.80 2 $ 97.90 • Bathroom Sink Faucet(Atlowarae) $ 396.00 2 $ 198.00 •• •• ••• ••i•• Faucet Supply Lines $ 13.68 2 $ 6.84 •• •• 6*0 0 ***000 Faucet Supply Valves $ 14.67 2 $ 7.34 6.4.6• • Toilet White(Allowance) $ 385.00 1 $ 385.00 • 0 • • • Toilet Supply Lines $ 6.84 1 $ 6.84 • • • • • New Tub Drain,Valve,Trim and Handheld Tub Head(Allowance) $ 770.00 1 $ 770.00 • • 6.4.6 0 • •••• New Soaking Tub(Allowance) $ 2,706.00 1 $ 2,706.00 • • • • • Shower Valve,Transfer,Pressure Balancing Valve with Lever Handle Trim(Allowance) $ 275.00 1 $ 275.00 •• • • 6•• ••••: Shower Rainhead(Allowance) $ 242.00 1 $ 242.00 • 6 • Hand Shower Kit(Allowance) $ 176.00 1 $ 176.00 •• • Shower Pan Liner $ 60.50 1 $ 60.50 Shower Pan Adhesive $ 8.44 1 $ 8.44 Misc.Plumbing Materials-- -_ $-._- 319, _ 00 1 $ 319.00 ,- _ Pl._Ufib1i9 A0 Su6 Total $ ,^. 8.94 iC+¢rpentry�YtatmtelsDemn „..;5. -_;,' _ Mirror(Allowance) $ 528.00 2 $ 264.00 Master Bathroom Accessories:24"Double Towel Bar(Allowance) $ 121.00 1 $ 121.00 Master Bathroom Accessories:Towel Ring(Allowance) $ 95.04 2 $ 47.52 Master Bathroom Accessories:Robe Hook(Allowance) $ 88.88 2 $ 44.44 Master Bathroom Accessories:Toilet Tissue Holder(Allowance) $ 50.60 1 $ 50.60 Master Bathroom Accessories:Glass Shelf(Allowance) $ 209.00 1 $ 209.00 Closet Doors and Hardware(Allowance) $ 682.00 2 $ 341.00 Full Closet Design Cabinets and Hanging Rids,White Core Board(Allowance) $ 5,280.00 2 $ 2,640.00 Shower Door,Glass and Hardware(Allowance $ 636.00 1 $ 638.00 Attic Access Ladder(Allowance) $ 253.00 1 $ 253.00 Vanity Cabknets 5(Aikrwance) _ $ 1,782.00 2 $ 891.00 _ _- _Carpen(�ll�a(erW 41b:7oie1 $ _,9,727.52 VLTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores,FL 33138 ca►oe�'roar_sa�rcani�rr=al�aerrin -. _.___ Badmpkmh Mosaic(Anaaarxe) $ 1,056.00 50 $ 21.12 Kitchen Courter Top and Fabrloa8on(AOowance) $ 4,213.00 1 $ 4,213.00 'iPwmblpgMe6�la/s�aU - _ _ UndennouM Single Bowl Kitchen Sink(Allowance) $ 383.00 1 $ 363.00 Pull-W Spray Kitchen Faucet(Allowance) $ 154.00 1 $ 154.00 SS Sink Strainers(Allowance) $ 54.99 1 $ 54.99 SS Garbage Disposal Rim(Allowance) $ 43.99 1 $ 43.99 Dishwasher Connector(Aflowm=) $ 21.99 1 $ 21.99 Faucet Supply Lines $ 13.68 2 $ 6.84 Supply Valves $ 14.67 2 $ 7.34 Garbage Disposal(Allowence) $ 383.00 1 $ 363.00 Disposal Power Cord $ 12.09 1 $ 12.09 P_-trap&Drain Linea $ _ 32.99 1 $ 32.99 carps; A Kitchen Base.Wall CaUrtets:White Flat,Maple Ply.Boxes(Anowarxe) $ 16,280.00 1 $ 16,280.00 2"Brushed Alumhhurn Hardee(Allowance) $ 61.60 20 $ 3.08 Wood Base Board(Allowance) $ 3960 20 $ 1.98 .. penLy Matetlal__0j $ >: 0000 � • • 0000• 0000•• 0000•• 0000 • • 0000•• 0000•• • 0000• 0000• �•0••: • 0000000• 0000• •00000• •00• • • 000.0• •00.0• • • •••0•• 0000•• • • ••• •0000• LEGAL DESCRIPTION: ___ ____�__ry ___ _ _ _____________ __ _ __ LOT 3, BLOCK 3 OF "RIVER—BAY PARK ADDITION" RECORDED IN PLAT BOOK 40, PAGE 72, OF THE PUBLIC RECORDS OF err,reee�w�n MIAMI—DADE COUNTY, FLORIDA. Elms " ■ Tm"rsideTerraee tow"de TwraceWffin%W soarers I NE l t}yth St ADDRESS: NE1o51h81 10 1399 N.E. 104TH STREET _ MIAMI SHORES, FLORIDA �W"'' ''"�'" � y r��raerst FLOOD ZONE: AE 9, MAP 12086CO306L, ,aNL 1041h St Nr 1041n qt NF TBatl,st DATE 9/11/2009 NF)04th St 0 r ' NE 103rd St SURVEY NOTES AND QUALIFICATIONS: z NEiwdst NE 103 ® N�1Aard SI 1. This survey map and report is not valid without the signature t'sWes ce11et and original•rtits�ed seal of Florida licensed surveyor and mapper high car»be sound at t" end of this survey. NLloznc�s< .�evations shown h1et8on;are based on the National Geodetic m .Vertical Dbidrtt•bf 1929 w NL 102 no St �. Benchmark referen;g:0 B-26—RA, EL=17.23 •4•Bearings•jSrYwn hereon are relative to the plat of "RIVER BAY tub 4 P SC ADDInO•IY"• P.B. 72,72, Miami—Dade County Records. ® NE101stst w eSt IR LB 672*7 at property corners unless other..*-- � ise ------------ — --------- _ o��v�—_____—_ noted • • . • • •74tegroperty contains e,40.50 square feet, more or less (TOTAL) 8. lfxpected'use of pldadlrkf is Residential. The minimum relative :Mstlance 01ruracy for6TMl`§•type of Boundary Survey is 1 ft. in 090,000 ft! Tht0ticcurVy, "brained by measurement & calculations • foundo**4exceed As requirement. .••0 BISCAYNE DRAINAGE CANAL SET NAIL SET NAIL & PCP TF= . . .. & PCP LB#6727 LB#6727 30.24' � � POST 3018' 1' SOUTH 90'00'00" , 0'00'00" WOOD POST I W/ LIGHT WOOD iFENCE 10.00'` 55.00 10.00' LOT LOT 3 BLOCK 23 I BLOCK 3 I UILDING (P.B. 40, PG. 72, (P.B. 40, PG. 72, ,(n VERHANG LOT 4 M.D.C.R.) I I M.D.C.R.) iv BLOCK 3 o ONE � ,od (P.B. 40, PG. 72, �I STORY '= M.D.C.R.) a RESIDENCE - a LOo; g FF.=8.30 .0 LO to 1 '�AC PAD EL=5.68 I GONG: ao ' 0 AC ON BRACKET : � CO 15.33' EL=8.15 I ----------- 98' ATE ° 0 N GATE' GARAGE M FF.=4.88 , , 10.07' • ..25.40' IRRIGAT10 I VALVE 0'00'00" , 90'00'00" 24.86 24.89' FND IR NO ID I ND IR 175.00' (P)(M 's WOOD OVERHEAD WATER METER POWER POLE ELECTRICAL i VAULT LECTRIC PULLBOX N.E. 104TH STREET 0: ASPHALT 0PAVEMENT D IR N.E. CORNER LOT 2, BLK 4 (P.B. 40, PG. 72, M.D.C.R.) 200.00' (P)(M ' For the Firm: So JDougI s essional Surveyor & Ma per Florida Registration No 4532 PREPARED Vi REVISIONS- Description Date Fb/ DRAWING DATA- DOUGLASS, LEAVY & ASSOCIATES INC. Drawing date-7-13-2015 LPQ fb/pg source-787/26 N PROFESSIONAL SURVEYORS & MAITM Drafter-BWA HORIZONTAL I `t 7914 WILES ROAD Checked-SJD SCALE (FT) CORAL SIMMS, FLORIDA 33067 CADD dwg no-15046 0 10 20 OFFICE: (954) �NNoo. 6 FAM (9") s44- S H E E T i 1 /1 ULTIMATE EjrRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence DATE 8/24/2015 13%NE 104 Mdrni Shores,FL 33138 yy sign-ow Daft Remove Flooring and Base at Location of New Entry and Powder $ 371.25 7.5 $ 49.50 $ 45.00 1.1 Remove CeiWtg Drywall only(framing to remahh) $ 24.75 0.5 $ 49.50 $ 45.00 1.1 Remove Existing Interior Wags and Drywall(framing to remain) $ 198.00 4 $ 49.50 $ 45.00 1.1 Remove Existing Entry Door and Window $ 396.00 8 $ 49.50 $ 46.00 1.1 L9e Ig ��^� Remove Existing Window Sm(to allow for new miry) $ 396.00 8 $ 49.50 $ 45.00 1.1 C r r- Datr swat S , 1.3�:SfO'rte i Y !./ V Infill Existing Entry Door $ 398.00 8 $ 49.60 $ 46.00 1.1 Finish Exterior To Match Adjacent Stucco FWsh $ 396.00 8 $ 49.50 $ 45.00 1.1 � ��1� Materials $ 150.00 1 $ 150.00 $ 150.00 1 VCT 2 aodSfacoS $ 942.00 Patch and Repair Exis ft Wags due to Demolition $ 198.00 4 $ 49.50 $ 46.00 Frame,Hang,and Finish New Wells $ 792.00 16 $ 49.50 $ 45.00 Hang,and Finish Caging $ 198.00 4 $ 49.50 $ 45.00 1.1 Materials $ _ 737.00 1 $ 737.00 $ 870.00 1.1 Floor Prep $ 49.50 1 $ 49.50 $ 45.00 1.1 Install Tge Flooring at New Powder $ 106.43 45 $ 2.37 $ 2.15 1.1 Install Wag Tile at Powder Room South Wall $ 232.38 65 $ 3.58 $ 3.25 1.1 Install Wag Tile at Covered Porde Entry $ 260.25 70 $ 3.58 $ 3.25 1.1 Materials u. _ $ 44.1.43 1 $ 441.43 $ 441.43 1 4 Prime Calling&Wags $ 59.40 300 $ 0.17 $ 0.15 1.1 Paint Calling&Walls $ 118.00 360 $ 0.33 $ 0.30 1.1 Paint Doors(Powder) $ 49.00 1 $ 49.50 $ 45.00 1.1 Paint&Materials $ 110.00 1 $ 110.00 $ 100.00 1.1 o r .'- SuDVOta/ $ 337:70 Install Countertop at Sink and A/C Return $ 247.50 5 $ 49.50 $ 45.00 1.1 Ma_teriats �_ _ _ $ 297 00. , 1 $ 297.00 $ 297.00 1 ab11� Coiahter740 $ t'` 544 bt1; Install Entry Door and Sloe Windows Assembly $ 1,782.00 36 $ 49.50 $ 45.00 1.1 Materials _ $ 3,344.00 1 $ 3,344.00 $ 3,040.00 1.1 6ffiir Door-and SA*WkWows Sia*Wt $ _612_ap-:i install Ceiling Light Fixtures and Swttdres $ 264.00 3 $ 88.00 S 00.00 1.1 Install New GFCI Outlets at Powder(2) $ 176.00 2 $ 88.00 $ 80.00 1.1 install New Outer per code(2) $ 176.00 2 $ 88.00 $ 80.00 1.1 Install New Toilet Fan and Switch $ 176.00 2 $ 88.00 $ 80.00 1.1 Relocate Existing Outlets(2)to Adjacent Wags at New location of Entry $ 176.00 2 $ 88.00 $ 80.00 1.1 Install New GFCI Outlets at Covered Porch(2) $ 176.00 2 $ 88.00 $ 80.00 1.1 Replace existing Caging Light with Surface Mounted one at Covered Porch $ 88.00 1 $ 88.00 $ 00.00 1.1 Materials $ 617.94 1 $ 617.94 $ 617.94 1 $ C1i�F Install New Water Supply and Drain tares for Toilet and Vanity $ 748.00 a $ 93.50 $ 85.00 1.1 Install Now Tollet $ 187.00 2 $ 93.50 $ 85.00 1.1 Install Faucet and Vanity Sink $ 187.00 2 $ 93.50 $ 85.00 1.1 Materials $ 1,300.20 1 $ 1,300.20 $ 1,300.20 1 rt a . :•_f3 [al $ 'a 2422.201 Install New Wood Base $ 49.50 1 $ 49.50 $ 45.00 1.1 Install New VaNty Cabhret $ 99.00 2 $ 49.50 $ 45.00 1.1 Install Door and Hardware(Powder? $ 198.00 4 $ 49.50 $ 45.00 1.1 Install Powder Room Accessories $ 49.50 1 $ 49.50 $ 45.00 1.1 Materials $_1,69_9.62 1 $ 1,599.62 $ 1,599.62 1 �- � ------F�• -t----�y � c ,CarypstdrySi�ofel $ 1,985y62�j' Kelsey Zealy Residence DATE: 8242015 1399 NE 104 Sftg Miami Shores FL 33138 alga om Date Remove Existing Flooring $ 1,980.00 40 $ 49.50 $ 45.00 1.1 Remove Existing Baseboard $ 398.00 8 $ 49.50 $ 45.00 1.1 Remove Existing DecoraWe Fire Place $ 396.00 8 $ 49.50 $ 45.00 1.1 Remove Exhding_W�Dinhtg room $ 396.00 8 $ 49.50 $ 45.00 1.1 ' ••, OarrANdga S onat,$ 31 Patch and Repair Existing Wags and Ceilings due to Demolition•• •i ••i 712.0; 16 $ 49.50 $ 45.00 1.1 Materials • • • • • 40•• 1 $ 290.40 $ 264.00 1.1 Prime Ceiling&Wells $ 340.73 2065 $ 0.17 $ 0.15 1.1 Paint Caging&Wells • ••• $ 681.45 2065 $ 0.33 $ 0.30 1.1 Paint&Materials • • • ••• •• 00 ••• 1 $ 572.00 $ 520.00 1.1 Floor Prep ••• • •• • 1,TO ft •• 24 $ 49.50 $ 45.00 1.1 Install Flooring OTs) $ 2,7 .32 • 1168 $ 2.37 $ 2.15 1.1 Materials(Allowance $ _1,071.95 1 $ 1,071.95 $ 1,071.95 1 •y`"0 • • • ••• • Install New Wood Base • • i i•i qW6.00 0 8 $ 49.50 $ 45.00 1.1 Materials • • • • • • Sa :M70! 1 $ 326.70 $ 326.70 1 tom; •s�- ULTIMATE#VIRONMENTS,INC. 1742 COSTA DEL SOL f BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence DATE: 824/2015 1399 NE 104§M Miami Shores FL 33138 Sign-0iN Date Remove Existing Flooring at Bathroom,Closet and Study $ 495.00 10 $ 49.50 $ 45.00 1.1 Remove Existing Portion of Caning for New Attic Access $ 49.50 1 $ 49.50 $ 45.00 1.1 Remove Existing Interior Partition per Plans $ 445.50 9 $ 49.50 $ 45.00 1.1 Remove Existing Plumbing Fixtures and Pipes $ 99.00 2 $ 49.50 $ 45.00 1.1 Remove Doors and Frames per Plans $ 198.00 4 $ 49.50 $ 45.00 1.1 Remove Existing Wap Finishes at Study $ 99.00 2 $ 49.50 $ 45.00 1.1 Remove Any Damaged Gyp.Bd.After the Removal of Wall Finish $ 74.25 1.5 $ 49.50 $ 45.00 1.1 Remove Existing Vanity Cat*> _$_ 24.75 0.5 $ 49.50 $ 45.00 1.1 �nitt i1A'i Patch and Repair Existing Wapa/Ceping due to Demolition $ 99.00 2 $ 49.50 $ 45.00 1.1 Frame,Hang and Finish New Walls $ 1,386.00 28 $ 49.50 $ 45.00 1.1 Materials _ $ 693.00 1 $ 893.00 $ 630.00 1.1 Sct6totaf $ '`2 78•P♦j Floor Prep $ 247.50 5 $ 49.50 $ 45.00 1.1 Install New Wood Flooring at Closets and Hallway $ 323.40 140 $ 2.31 $ 2.10 1.1 Install Muer Bathroom Floor(rile) $ 331.10 140 $ 2.37 $ 2.15 1.1 Install Shower Pan(Tpe) $ 330.00 1 $ 330.00 $ 300.00 1.1 Install Wall Tile(Shower and 4'up on all Bathroom Walls) $ 1,108.25 310 $ 3.58 $ 3.25 1.1 Install Transitions!Strips between Wood and Tpe Flooring $ 99.00 2 $ 49.50 $ 45.00 1.1 Materials $ 3,060.75 1 $ 3,060.75 $ 3,060.75 1 Prime CeiMg&Wells $ 145.20 880 $ 0.17 $ 0.15 1.1 Paint Ceiling&Walls $ 290.40 880 $ 0.33 $ 0.30 1.1 Paint&Materials $ 242.00 1 $ 242.00 $ 220.00 1.1 _ <Y;.PatrdUxrSai ,._�_87780{ T Install Countertop(Sink) $ 198.00 4 $ 49.50 $ 45.00 1.1 Materials $ 1350.00 1 $ 1,350.00 $ 1,350.00 1 Install Recessed Ceiling Light Fbdures and Switches $ 704.00 8 $ 88.00 $ 80.00 1.1 Install Surface Mounted Light Fbdurss and Switdres $ 264.00 3 $ 88.00 $ 80.00 1.1 Install Wap Sconces and Switch $ 176.00 2 $ 88.00 $ 80.00 1.1 Install New GFCI Outlets $ 178.00 2 $ 88.00 $ 80.00 1.1 Install New Outlets per code(5) $ 284.00 3 $ 88.00 $ 80.00 1.1 Install New Toper Fan and Switch $ 178.00 2 $ 88.00 $ 80.00 1.1 Install New 50 AMP Wire and Outlet for Water Heater $ 352.00 4 $ 88.00 $ 80.00 1.1 Install New Power for AC System $ 352.00 4 $ 88.00 $ 80.00 1.1 Materials _ $ _1,807.17 1 $ 1,807.17 $ 1,807.17 1 Install Pre-Fab Concrete Slab for Condenser Unit $ 88.00 1 $ 88.00 $ 80.00 1.1 Install Condenser Unit $ 704.00 8 $ 88.00 $ 80.00 1.1 Install Air Handler Unit $ 704.00 8 $ 88.00 $ 80.00 1.1 Install New Ductwork and Diffusers $ 1,408.00 18 $ 88.00 $ 80.00 1.1 Install Refrigerant Piping and Condensate Drain $ 2,024.00 23 $ 88.00 $ 80.00 1.1 Materials $ 6,284.25 1 $ 8,284.25 $ 6,284.25 1 Move/Retocate Water and Drain Lines to New Location of Plumbbg Fbdnras $ 2,150.50 23 $ 93.50 $ 85.00 1.1 Install New Toilet $ 93.50 1 $ 93.50 $ 85.00 1.1 Install Faucets and Vanity Sinks $ 187.00 2 $ 93.50 $ 85.00 1.1 Install Nene Shower Manifold,Trim and Shower Head $ 374.00 4 $ 93.50 $ 85.00 1.1 Install New Hand Hold Shower Head for New Tub $ 374.00 4 $ 93.50 $ 85.00 1.1 Install New Soaking Tub $ 187.00 2 $ 93.50 $ 85.00 1.1 Mater�ls _ _ $ 5,568.94 1 $ 5,588.94 $ 5,568.94 1 Install New Vanity Cabinets $ 198.00 4 $ 49.50 $ 45.00 1.1 Install New Mhrors $ 99.00 2 $ 49.50 $ 45.00 1.1 Install Master Bathroom Accessories $ 198.00 4 $ 49.50 $ 45.00 1.1 Install New Shower Door and Glass $ 198.00 4 $ 49.50 $ 45.00 1.1 Install New Closet Doors(2) $ 198.00 4 $ 49.50 $ 45.00 1.1 Instep Closet Shelving,Cabhrets,Rods and Hardware $ 792.00 16 $ 49.50 $ 45.00 1.1 Install New Ladder for Attic Access $ 198.00 4 $ 49.50 $ 45.00 1.1 Materials _ _ $ 9,727.52 1 $ 9,727.52 $ 9,727.52 1 •• ••• • • • • • •• 00 • •• • • • • ••• • •• ••• •• • • • •• • ••• • ••• • ••• • • • • • • • •• ••• • ••• ••• • • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL y BOLA RATON,FL 33432 • P.561.998.3643 J F.561.998.1697 Kelsey Zealy Residence DATE: 8/24/2015 1399 NE 104 Street Miami Shores,FL 33138 l lwwXff Date Remove Existlng Appliances,Sink,and Drain Lines $ 198.00 4 $ 49.50 $ 45.00 1.1 Remove Exift Counter Tops and Cabinets $ 594.00 12 $ 49.50 $ 45.00 1.1 Remove Trim and Moldings $ 49.50 1 $ 49.50 $ 45.00 1.1 OeiS $ -x, 841.50 Patch and Repair Existing Walls/Ceiling due to any existing damages $ 198.00 4 $ 49.50 $ 45.00 1.1 Materials $ 66.00 1 $ 66.00 $ 60.00 1.1 ,� s�uEdatat $ .QO? Prime Ceiling&wens $ 66.00 400 $ 0.17 $ 0.15 1.1 Paint Ceiling&Web $ 132.00 400 $ 0.33 $ 0.30 1.1 Palm&Materials $ 121.00 1 $ 121.00 $ 110.00 1.1 � Install/Seal Badwplash $ 183.15 45 $ 4.07 $ 3.70 1.1 Install Countertops $ 594.00 12 $ 49.50 $ 45.00 1.1 Materials $ 5,269.00 1 $ 5,269.00 $ 5,269.00 1 Install Garbage Disposal $ 167.00 2 $ 93.50 $ 85.00 1.1 Instep New Water Line to Steam Oven $ 187.00 2 $ 93.50 $ 85.00 1.1 Install Drain and water Supply Ltrres $ 280.50 3 $ 93.50 $ 85.00 1.1 Install Faucet and Sink Drain $ 187.00 2 $ 93.50 $ 85.00 1.1 Install Undennount Sink $ 167.00 2 $ 93.50 $ 85.00 1.1 Materials $ 1,074.40 1 $ 1,074.40 $ 1,074.40 1 -- a s.. PIrMaw $ ,2,102 Install Base and Wan Cebtrsts $ 1,138.50 23 $ 49.50 $ 45.00 1.1 Install Baseboard $ 49.50 1 $ 49.50 $ 45.00 1.1 Materials _ $ 16 381.20 1 $ 16,381.20 $ 16,381.20 1 ` z t mySru V$ 17589M Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores FL 33138 Supervision $ 4,510.00 1/$ 4,510.00 $ 4,100.00 1.1 Trash Removal and Dump Fees $ 1,650.00 1 $ 1,650.00 $ 11500.00 1.1 General Cleaning and Prep $ 1,089.00 1 $ 11089.00 $ 990.00 1.1 Material and Labor Transport $ 4,224.00 1 $ 4,224.00 $ 3,840.00 1.1 Insurance $ 1,166.00 1 $ 1,166.00 $ 11080.00 1.1 Jim tApd! • o • e _sem. , .,*t" 4�..., "%`.- .�M ,. _.ZIM •• ••• • • • • • •• • •• • • • • ••• • •• as: •• • • • •• • ••• • ••• • ••• • • • • • • • • •• • • •• • • • • • ••• • ••• ••• • • •• • ••• • • • • ••• • • 000 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL 33432 z r � P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Strea Miami Shores FL 33138 waft"PM Anti Fracture Membrane(Aliowence) $ 38.50 50 $ 0.77 $ 0.70 1.1 Floor Tdle Powder Room(Allowance) $ 82.50 50 $ 1.65 $ 1.50 1.1 Wall Tile Powder Room(Allowance) $ 142.56 72 $ 1.98 $ 1.80 1.1 Well Tile Covered Porch Entry Travertine,to Match Porch FloorAllowance_ _ ((_ _y(�`�..� ) $ ----1-7'-7-.87 77 $ 2.31 $ 2.10 1.1 -i Counter Top Material and Fabrication(Allowance) It 297.00 1 $ 297.00 $ 270.00 1.1 800w Single pole Dimmer(Allowanc al J $ 24.20 1 $ 24.20 $ 22.00 1.1 Single Pole Lighted Switch(Allowance) $ 2.75 1 $ 2.75 $ 2.50 1.1 15 Amp GFCI(Allowance) $ 55.40 4 $ 13.85 $ 12.59 1.1 15-Amp Outlet and Cover Plate(Allowance) $ 7.59 3 $ 2.53 $ 2.30 1.1 Exhaust Fan(Allowance) $ 110.00 1 $ 110.00 $ 100.00 1.1 Powder Recessed Can Light(Allowance) $ 220.00 4 $ 55.00 $ 50.00 1.1 Covered Porch Calling Mounted Light(Aliowance) $ 99.00 1 $ 99.00 $ 90.00 1.1 ,Misc.Electrical Materials _ $ 99.00 1 $ 99.00 $ 90.00 1.1 f ' 617:84] [PG1rnb_In�_Afaterta� ll , ; � ��1 Vanity Sink(A9owarroe) $ 242.00 1 $ 242.00 $ 220.00 1.1 Bathroom Sink Faucet(Allowance) $ 198.00 1 $ 198.00 $ 180.00 1.1 Faucet Supply Lines $ 13.68 2 $ 6.84 $ 6.22 1.1 Faucet Supply Valves $ 14.67 2 $ 7.34 $ 6.67 1.1 Tollet White(Allowance) $ 385.00 1 $ 385.00 $ 350.00 1.1 Totiet Supply Uses $ 6.84 1 $ 6.84 $ 6.22 1.1 Misc.Plumbing Materials $ 440.00 1 $ 440.00 $ 400.00 1.1 �,��..����� <° • ' ,� P/umboruMatertelSSuk.Totat_��13�.20a IC,arAanbYlsaet9il � °�' ' Door and Hardware(Allowance) $ 385.00 1 $ 385.00 $ 350.00 1.1 Wood Base Board(Allowance) $ 49.50 25 $ 1.98 $ 1.80 1.1 Vanity Cabinet V-W(Allowance) $ 1,067.00 1 $ 1,067.00 $ 970.00 1.1 Powder Room Accessories:Paper Holder(Allowance) $ 50.60 1 $ 50.60 $ 46.00 1.1 Powder Room Accessories Towel $ 47.52 1 $ 47.52 $ 43.20 1.1 Kelsey Zealy Residence 1389 NE 104 Miami Shores,FL 33138 ry Ftoor7rlAAletrtigfOeta(!"'. � ,___ i Anti Fracture Membrane(Allowance) $ 989.45 1285 $ 0.77 $ 0.70 1.1 Floor Ttie(AAowanoe) $ 8250 50 $ 1.65 $ 1.50 1.1 �A�rtetlsiSDatail�'����� .._� -h<�'•-#�3 Wood Base Board nce) $ 326.70 165 $ 1.98 $ 1.80 1.1 •• •Y• • • • • • •• as • ••• • ••• • ••• •• • • •• • • • • • •• • • • • • •• ••• • •• • • ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• ••• 0 0 0 ••• 0 • ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores FL 33138 ® ' kd.C4lit. dWArlt "fCLC+AfMt.z l9awrlrtgtfla/er18t_DOXatl Anti Fracture Membrane(Allowance) $ 234.85 305 $ 0.77 $ 0.70 1.1 Master Bathroom Floor The(Allowance) $ 287.98 154 $ 1.67 $ 1.70 1.1 Tub Wall The(Allowance) $ 224.40 80 $ 2.81 $ 2.65 1.1 Shower Wag Ile(Allowance) $ 953.70 340 $ 2.81 $ 2.55 1.1 Shower Pan TAe Flooring Mosaic(Allowance) $ 309.76 16 $ 19.36 $ 17.60 1.1 Wood Flowing Plank(Allowance) $ 830.06 154 $ 5.39 $ 4.90 1.1 Glue $ 154.00 1 $ 154.00 $ 140.00 1.1 Trensibonal Stripa(AAowence) $ 66.00 6 $ 11.00 $ 10.00 1.1 Cour�Top fit! Courter Top Material arM Fabrication(AAowarrce) $ 1,350.00 1 $ 1,350.00 $ 1,350.00 1 600w Single pole Dimmer(Allowance) $ 72.60 3 $ 24.20 $ 22.00 1.1 Single Pole Lighted Switch(Allowance) $ 13.75 5 $ 2.75 $ 2.50 1.1 15 Amp GFCI(Allowance) $ 27.70 2 $ 13.85 $ 12.59 1.1 15-AM Outlet and Cover Plate(Allowance) $ 10.12 4 $ 2.53 $ 2.30 1.1 Exhaust Fan(Allowance) $ 110.00 1 $ 110.00 $ 100.00 1.1 4"Recessed Can Light(Allowance) $ 550.00 10 $ 55.00 $ 50.00 1.1 LED Surface Mounted Light at Closet(Allowance) $ 308.00 4 $ 77.00 $ 70.00 1.1 Electric Water Heater(Allowance) $ 495.00 1 $ 495.00 $ 450.00 1.1 Misc_Electrical Materials $ 220.00 1 $ 220.00 $ 200.00 1.1 -_-�-- -- _. _ �, :�s., ' :.��..,=€�dcal: te_rfe/sSub�:T�tal $__•"tt�7.971 kA 1.5 Tons 17 Seer Trane Unit:(Air Handler GAM5BOAMICondensing unit 4TTX6018) $ 5,881.00 1 $ 6,881.00 $ 51881.00 1 Misc.AC Materials $ 403.25 1 $ 403.25 $ 403.25 1 _� �"� " ter+��� ACb)Bi6tiafsSub;Tm®t._�__;�284:251 - -- - - ��JumbingMatartafei ,.-__ Vanity Sink(Allowance) $ 195.80 2 $ 97.90 $ 89.00 1.1 Bathroom Sink Faucet(Allowance) $ 396.00 2 $ 196.00 $ 180.00 1.1 Faucet Supply Lines $ 13.68 2 $ 6.84 $ 6.22 1.1 Faucet Supply Valves $ 14.67 2 $ 7.34 $ 6.67 1.1 Toilet White(Allowance) $ 385.00 1 $ 385.00 $ 350.00 1.1 Toilet Supply Lines $ 6.84 1 $ 6.84 $ 6.22 1.1 New Tub Drain,Valve,Trim and Handheld Tub Head(Allowance) $ 770.00 1 $ 770.00 $ 700.00 1.1 New Soaldng Tub(Allowance) $ 2,706.00 1 $ 2,706.00 $ 2,460.00 1.1 Shower Valve,Transfer,Pressure Balancing Valve with Lever Handle Trim(Allowance) $ 275.00 1 $ 275.00 $ 250.00 1.1 Shower Rainhead(Allowance) $ 242.00 1 $ 242.00 $ 220.00 1.1 Hand Shower 10t(Allowance) $ 176.00 1 $ 176.00 $ 160.00 1.1 Shower Pan Wier $ 60.50 1 $ 60.50 $ 55.00 1.1 Shower Pan Adhesive $ 8.44 1 $ 8.44 $ 7.67 1.1 Misc Plumbing Materials _ $ 319.00 1 $ 319.00 $ 290.00 1.1 Sub Tom ��S 588.94 Mirror(Allowance) $ 528.00 2 $ 264.00 $ 240.00 1.1 Master Bathroom Accessories 24"Double Towel Bar 0110warm) $ 121.00 1 $ 121.00 $ 110.00 1.1 Master Bathroom Accessories:Towel Ring(Allowance) $ 95.04 2 $ 47.52 $ 43.20 1.1 Master Bathroom Accessories:Robe Hook(Allowance) $ 88.88 2 $ 44.44 $ 40.40 1.1 Master Bathroom Accessories:Toilet Tissue Holder(Allowance) $ 50.60 1 $ 50.80 $ 46.00 1.1 Master Bathroom Accessories:Glass Shell(Allowance) $ 209.00 1 $ 209.00 $ 190.00 1.1 Closet Doors and Hardware(Allowance) $ 682.00 2 $ 341.00 $ 310.00 1.1 Full Closet Design Cabinets and Hanging Rids,White Core Board(AWwance) $ 5,280.00 2 $ 2,640.00 $ 2,400.00 1.1 Shower Dow,Glass and Hardware(Allowance $ 638.00 1 $ 638.00 $ 580.00 1.1 Attic Access Ladder(Allowance) $ 253.00 1 $ 263.00 $ 230.00 1.1 Verity Cabkrets 5(AAowance)_ $ 1,782.00 2 $ 891.00 $ 810.00 1.1 _U7 752 •• ••• • • • ♦ • f• •• ••• •• • • • •• •• • • •• • • • • • 0 • • ••• • • ULTIMATE ENVIRONMENTS,INC. 1742 COSTA DEL SQL BOCA RATON,FL 33432 P.561.998.3643 F.561.998.1697 Kelsey Zealy Residence 1399 NE 104 Miami Shores FL 33136 Becksplash Mosaic(Allowance) $ 1,056.00 50 $ 21.12 $ 19.20 1.1 Kitchen Counter Top and FabAcatlon�Ailotvance) $ 4,213.00 1 $ 4,213.00 $ 3,830.00 1.1 Undennount Single Bowl Kitchen Sink(Allowance) $ 363.00 1 $ 363.00 $ 330.00 1.1 Pull-Out Spray Kitchen Faucet(Allowance) $ 154.00 1 $ 154.00 $ 140.00 1.1 SS Sink Strainers(Allowance) $ 54.99 1 $ 54.99 $ 49.99 1.1 SS Garbage Disposal Rim(Allowance) $ 43.99 1 $ 43.99 $ 39.99 1.1 Dishwasher Connector(Allowance) $ 21.99 1 $ 21.99 $ 19.99 1.1 Faucet Supply tares $ 13.68 2 $ 6.84 $ 6.22 1.1 Supply Valves $ 14.67 2 $ 7.34 $ 6.67 1.1 Garbage Disposal(Atlowance) $ 363.00 1 $ 363.00 $ 330.00 1.1 Disposal Power Cord $ 12.09 1 $ 12.09 $ 10.99 1.1 P-trap 8 Drain Lures _ $ 32.99 1 $ 32.99 $ 29.99 1.1 LGa YArallarta)s Kitchen Base/Wall Cabinets:White Flat,Maple Ply.Boxes(Allowar>ce) $ 16,280.00 1 $ 16,280.00 $ 14,600.00 1.1 2"Brushed Aluminum Handles(Allowance) $ 61.60 20 $ 3.08 $ 2.80 1.1 Wood Base Board(AAowance) $ 39.60 20 $ 1.96 $ 1.80 1.1 as ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• • ••• • ••• • ••• •• • • i i • ••• • ••• ••• • • •• • ••• • • • • ••• • • • • 0 0 • • • • ' r SIW Impact Windows and Doors QUOTATION Quote Number: 233206Q Sales Rep: Oby Lombard Quote Date: 04/09/2015 Terms: 50% Deposit Quote Expires on: 05/09/2015 Date Printed: 04/09/2015 Route: PALM Palm Beach Ship VIA: Bill To: ULTIMATE ENV Ship To: ULTIMATE ENVIROMENTS ULTIMATE ENVIROMENTS 1742 COSTA DEL SOL 1742 COSTA DEL SOL BOCA RATON, FL 33432- BOCA RATON, FL 33445- Qty Product Description Unit Net Extended 040915-UE 01-1- (+12/-70 0 P F-� 1 SIW FRENCH DOOR XX(w/LH+RH SIDELITE) RH ACTIVE OUTSWING 606816(108"x 80"x 72")WHITE FRAME GREY GLASS 7/16 IMPACT HS -81N BOTT RAIL-US15 SATIN NICKEL HINGE-SENTINEL MULTI-POINT LOCK NOTES : -IT IS FULLY RESPONSABILITY OF CUSTOMER TO VERIFY SIZES,WINDOW TYPES, DOOR SWINGS, PRESSURES,ALUMINUM FINISH, GLASS TYPE AND TINT."-Please provide tip to tip size(including a 1/2" flange on windows)mfg takes no deduction" ALL MERCHANDISE MUST BE PAID AND FULL PRIOR TO PICK UP OR DELIVERY. .. ... . . . . . .. PLEASE SIGN X TO • •• :.: PROCEED WITH THE ORDER. ' ' ' • .. ... .. . . . .. lotaI MatehaTs: 2,628.00 • •; • gulls-Cax: 157.68 QUOTE Total Amount > 2,785.68 ... . . . . ••• . +t• r tvP, oU�cEr- LrC4Ya .Qs� 13retc g t �•`� t j e } tt ( _ ,.q.� �..± �'• Lap � a ,. :+ - ; ,-- 31 IT 414 G9 �� Ti j 5't PLO j- z i f ---•• ••-:�••�•an,--•.rte � • L • _- __ lit p TF so ( _ t•-.�1._ . . . -000 ev I r i7o r�( 0 w•• • • • • w s •. � i ••• • •o ,•,w r i u rw'� *tea-� � �� ,,, ^'"��f�'�, ,b�' ` . . . . . . . . . . + ULTIMATE 1742 COSTA DEL SOL,BOIA nTON tLORtDA•33t32 tF- ... ... ... 561.998.3643 F: 561.998 1697 ENVIRONMENTS,INC. ' ' ' ' ' ' ' ' ' CGC 1510686 . . . GENERAL CONTRACTORS •• • • • •• ••• •• March 8d', 2016 •• ••• •• Permit number: 16-420 Reply to Building Critique dated 3-7-2016 The job cost estimate submitted previously and dated February 2"d, 2016 includes a 15%overhead and profit cost built into it. So 15%of each line item is our overhead and profit. David Habeck, President i www,uecontractors.com ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 Scope of VVOrk- Total Cost uift.,Quan i Price/Each' entottt�o �, s sign-OW-Date Remove Flooring and Base at Location of New Entry and Powder $ 225.00 7.5 $ 30.00 Remove Ceiling Drywall only(framing to remain) $ 15.00 0.5 $ 30.00 Remove Existing Interior Walls and Drywall(framing to remain) $ 120.00 4 $ 30.00 Remove Existing Entry Door and Window $ 240.00 8 $ 30.00 v Existing Window_Sill(to allow for new entry) $ 240.00 8 $ 30.00 GMU andDemol/kon Subtotal $ _ 840.00 o Stucc - -. . Infill Existing Entry Door $ 240.00 8 $ 30.00 Finish Exterior To Match Adjacent Stucco Finish $ 240.00 8 $ 30.00 Materials $ 150.00 1 $ 150.00 CMU and ft=Subtotal $ 630.001` �Fram]nglt)rywalG<� Patch and Repair Existing Walls due to Demolition $ 120.00 4 $ 30.00 Frame,Hang,and Finish New Walls $ 480.00 16 $ 30.00 Hang,and Finish Ceiling $ 120.00 4 $ 30.00 Materials $ 670.00 1 $ 670.00 Framlrtg/DrywaR_Subtota! 1;_390.00 [�tcortng/Yllatt Tq�� -- Floor Prep $ 30.00 1 $ 30.00 Install Tile Flooring at New Powder $ 187.50 50 $ 3.75 Install Wall Tile at Powder Room South Wall $ 243.75 65 $ 3.75 Install Wall Tile at Covered Porch Entry $ 262.50 70 $ 3.75 Materials $ 366.30 1 $ 366.30 kPatntin_g _. Fhrng Subtotal,;$ 1,090.05 � .. Prime Ceiling&Walls $ 54.00 360 $ 0.15 Paint Ceiling&Walls $ 108.00 360 $ 0.30 Paint Doors(Powder) $ 30.00 1 $ 30.00 Paint&Materials $ 100.00 1 $ •00100 Paint'PaintiV Subtotal $ 292.00 •Goes• lctv Install Countertop at Sink and A/C Return $ 150.00 5 $ •••••• • •••••• Materials $ 270.001 $ 270.00 Carmm_ ter,Top Subtotal__$ ,; ,420.t}0 •••••• " �-` e •••• • • • • ntry►Door dnd`6l VWii wws � ��. Install Entry Door and Side Windows Assembly $ 1,080.00 • 36 $ • 30.00 �: • Materials $ 3,040.00 •• •• 1 $ �QO ••••• EntryDoor and Side Windom Squblotat $ 4,120.00 •• •• •• • •••• • �J*IeCtrlCa4 :0*:*: • • Install Ceiling Light Fixtures and Switches $ 150.00 3 $ • ( ) $ 100.00 2 $ • 50.00 S�OQ •••••• Install New GFCI Outlets at Powder 2 & . • • • • Install New Outlets per code(2) $ 100.00 '..' :2 $ •.ODO Install New Toilet Fan and Switch $ 100.00 2 $ '.4.00 Relocate Existing Outlets(2)to Adjacent Walls at New Location of Entry $ 100.00 2 $ 50.00 Install New GFCI Outlets at Covered Porch(2) $ 100.00 2 $ 50.00 Replace existing Ceiling Light with Surface Mounted one at Covered Porch $ 50.00 1 $ 50.00 Materials $ 561.76 1 $ 561.76 ElectriealSubtoiar - 1,261.76:' Install New Water Supply and Drain Lines for Toilet and Vanity $ 400.00 8 $ 50.00 Install New Toilet $ 100.00 2 $ 50.00 Install Faucet and Vanity Sink $ 100.00 2 $ 50.00 Materials $ 1,182.00 1 $ 1,182.00 Plumbing Subtotal $ 1,782.00 Install New Wood Base $ 30.00 1 $ 30.00 Install New Vanity Cabinet $ 60.00 2 $ 30.00 Install Door and Hardware(Powder) $ 120.00 4 $ 30.00 Install Powder Room Accessories $ 30.00 1 $ 30.00 Materials $ 1,454.20 1 $ 1,454.20 Carpentry Subtotal $ 1,694.20 Enhy Total $ 13,520.01 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 cope p Work ®a, , a®. — ® ®® .- y Total Cost Qua Price/Each Oittit�ttJt71 Sign-Off/Date Remove Epsting Flooring $ 1,200.00 40 $ 30.00 Remove F)dsting Baseboard $ 240.00 8 $ 30.00 Remove Existing Decorative Fire Place $ 240.00 8 $ 30.00 Remove F)dsting Bar by Dining room $ 240.00 8 $ 30.00 4Framing/DrywaO y Demnhtlon;Subtotal $ 1,920.00;' Patch and Repair Existing Walls and Ceilings due to Demolition $ 480.00 16 $ 30.00 Materials $ 264.00 1 $ 264.00 FramurglUrywagSubtotal $ 744.00' (Patirr�ng^-- Prime Ceiling&Walls $ 309.75 2065 $ 0.15 Paint Ceiling&Walls $ 619.50 2065 $ 0.30 Paint&Materials $ 520.00 1 $ 520.00 PaintirutSubtotal_ $ 7,449.25 Floor Prep $ 720.00 24 $ 30.00 Install Flooring(Tile) $ 4,312.50 1150 $ 3.75 Materials $ 1,725.00 1 $ 1,725.00 Flooring Subtotal $ 6,757.50 (Carpentry Install New Wood Base $ 240.00 8 $ 30.00 Materials $ 297.00 1 $ 297.00 Carpentry Subtotal'$ 537.00 Dining/UvtngWasterBedroom Total $ 11,407.75 • • •••• •••••• 00 0 •••••• • •• •••••• • •••••• •••• ••••• •• •• •• • •••••• • ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL = BOCA RATON,FL.33432 P. 561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 cop��of Work �" o .®® ®® ® � „Total Cost Quantity Price/Each mlotititJil- n.,_s�,_ Stgn-W Date Remove Existing Flooring at Bathroom,Closet and Study $ 300.00 10 $ 30.00 Remove Existing Portion of Ceiling for New Attic Access $ 30.00 1 $ 30.00 Remove Existing Interior Partition per Plans $ 270.00 9 $ 30.00 Remove Existing Plumbing Fixtures and Pipes $ 60.00 2 $ 30.00 Remove Doors and Frames per Plans $ 120.00 4 $ 30.00 Remove Existing Wall Finishes at Study $ 60.00 2 $ 30.00 Remove Any Damaged Gyp.Bd.After the Removal of Wall Finish $ 45.00 1.5 $ 30.00 Remove Existing Vanity Cabinet $ 15.00 0.5 $ 30.00 Demolition Subtotal._$ 900.00 mingiGrpwatt " Patch and Repair Existing Walls/Ceiling due to Demolition $ 60.00 2 $ 30.00 Frame,Hang and Finish New Walls $ 840.00 28 $ 30.00 Materials $ 630.00 1 $ 630.00 Framf{tg/Qryuva!lSubtotal '$ 1,530.00 [FtooringlWai!Tito� _ Floor Prep $ 150.00 5 $ 30.00 Install New Wood Flooring at Closets and Hallway $ 350.00 140 $ 2.50 Install Master Bathroom Floor(Tile) $ 525.00 140 $ 3.75 Install Shower Pan(Tile) $ 300.00 1 $ 300.00 Install Wall Tile(Shower and 4'up on all Bathroom Walls) $ 1,333.00 310 $ 4.30 Install Transitional Strips between Wood and Tile Flooring $ 60.00 2 $ 30.00 Materials $ 2,245.60 1 $ 2,245.60 Flotuing/WallTile'Subtotal $ 4,963.60 Prime Ceiling&Walls $ 132.00 880 $ 0.15 Paint Ceiling&Walls $ 264.00 880 $ 0.30 Paint&Materials $ 220.00 1 $ 220.00 Painting Subtotal, $. . 616.00" �CUtltef"1''��..,..____...,�r •= Y_�,.,_�.z_..�s�_.... atas�at�e � .r�', •••• • • Install Countertop(Sink) $ 120.00 • • 4 $ ••30!00 •"••• • Materials $ 1,350.00 •••• :1 $ •1!350100 • = CountelTop-Subtotal-''$ '1,470.00 •••••• i •••• ••••i• [) 1+sctrScal - - - • Install Recessed Ceiling Light Fixtures and Switches $ 400.00 *:::: 8 $ . 50,00 :'00'. Install Surface Mounted Light Fixtures and Switches $ 150.00 000.003 $ ••bbVb ••.•• Install Wall Sconces and Switch $ 100.00 2 $ 50.00 • • Install New GFCI Outlets .••••• •••• ••••• $ 100.00 • •2 $ • 50.00 Install New Outlets per code(5) $ 150.00 " '• 3 $ •150.0b ••••:• Install New Toilet Fan and Switch $ 100.00 :••;•;2 $ 56.00 •• Install New 50 AMP Wire and Outlet for Water Heater $ 200.00 • •4 $ •659pp ••"'• Install New Power for AC System $ 200.00 • • 4 $ • 50.00 • • Materials $ 1,642.88 •••• i 1 $ 1}6Alz 88 ••••• Electrical Subtotal _$ 31042.88. '.00 • Install Pre-Fab Concrete Slab for Condenser Unit $ 50.00 1 $ 50.00 Install Condenser Unit $ 400.00 8 $ 50.00 Install Air Handler Unit $ 400.00 8 $ 50.00 Install New Ductwork and Diffusers $ 800.00 16 $ 50.00 Install Refrigerant Piping and Condensate Drain $ 1,150.00 23 $ 50.00 Materials $ 6,284.25 1 $ 6,284.25 FPlumbingw AC Subtotal $ 9,084.25 Move/Relocate Water and Drain Lines to New Location of Plumbing Fixtures $ 1,380.00 23 $ 60.00 Install New Toilet $ 60.00 1 $ 60.00 Install Faucets and Vanity Sinks $ 120.00 2 $ 60.00 Install New Shower Manifold,Trim and Shower Head $ 240.00 4 $ 60.00 Install New Hand Held Shower Head for New Tub $ 240.00 4 $ 60.00 Install New Soaking Tub $ 120.00 2 $ 60.00 Materials $ 5,062.67 1 $ 5,062.67 Plumbing Subtotat ,`$ 7,222.67 Install New Vanity Cabinets $ 120.00 4 $ 30.00 Install New Mirrors $ 60.00 2 $ 30.00 Install Master Bathroom Accessories $ 120.00 4 $ 30.00 Install New Shower Door and Glass $ 120.00 4 $ 30.00 Install New Closet Doors(2) $ 120.00 4 $ 30.00 Install New Ladder for Attic Access $ 120.00 4 $ 30.00 Materials $ 4,043.20 1 $ 4,043.20 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 - P.561.998.3643 Carpentry Subtotal $ 4,703.20 F.561.998.1697 Master Bathroom and Closets Total $ 33,532.60 90.9 • •0.0 •Y900• •• • •• • • 0000•• • •• 0000•• • 0000•0 • • • •0.004 0000 • • • • • • 01•••• 0000 4 •0090 00 0000•• •400 0000• 4• •• 00 • ••Y4•• • 0000•• • • • • • 4 •0409• •90.0• • • • • • • • • 669009 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 Scope of Work ., =� �, , _ _ - TotalCost ,� � Quantity, Price/Each`' +,F' Sign Offl Date Remove Existing Flooring $ 120.00 4 $ 30.00 Remove Ebsting Appliances,Sink,and Drain Lines $ 120.00 4 $ 30.00 Remove Existing Counter Tops and Cabinets $ 360.00 12 $ 30.00 Remove Trim and Moldings $ -30.00 1 $ 30.00 __ . t)emolida►Subiotal .$ 630.00 f FramingiDryvralt Patch and Repair Existing Walls/Ceiling due to any existing damages $ 120.00 4 $ 30.00 Materials $ 60.00 1 $ 60.00 Framing/Drywaff Subtotal`$ x 180.00 �FfooFlnB Floor Prep $ 240.00 8 $ 30.00 Install Flooring(Tile) $ 787.50 210 $ 3.75 Materials(Allowance) $ 315.00 1 $ 315.00 Flooring Subtotal $ 1,342.50' CPainting , � _ Prime Ceiling&Walls $ 60.00 400 $ 0.15 Paint Ceiling&Walls $ 120.00 400 $ 0.30 Paint&Materials $ 110.00 1 $ 110.00 _ f;: - _ #W1!9Subtotal._$^ 290.00_ f GouMr TpslBacs oAla:;h .. . Install/Seal Backsplash $ 166.50 45 $ 3.70 Install Countertops $ 360.00 12 $ 30.00 Materials $ 4,790.00 1 $ 4,790.00 lumbtng CoWftr7op/Backsplash=Subtotal '$ 5,316.50'' 4> , Install Garbage Disposal $ 120.00 2 $ 60.00 Install New Water Line to Steam Oven $ 120.00 2 $ 60.00 Install Drain and Water Supply Lines $ 180.00 3 $ 60.00 Install Faucet and Sink Drain $ 120.00 2 $ •O%t% Install Undermount Sink $ 120.00 • • 2 $ 0"00 •••••• Materials $ 976.73 •••• .1 $ ••976.9 •• - - J11Plumbing Subtotal $ 1,636.73 •••••• i ••• ••••i• Install Base and Wall Cabinets *:::: *23• • • • $ 690.00 • $ • 30p0 .••••i Install Baseboard $ 30.00 ••••••1 $ •M." ••••• q9 • • Materials $ 14,892.00 1 $ 14 8 _ •••••• iii'i- 0#000 K�tciren Total Carpentry Subtotat • $ 15;612.0(1 . . . - $, 25,007.73 •• •• •• • ••••�• Kelsey Zealy Residence DATE: 2/11/2016 • • •••••• 1399 NE 104 Street,Miami Shores,FL 33138 • • • • • .ScO G of Y.�/r �LL}..... �,.,. sq�' ,.i as ,.�3-.n • • ® m ® ` Total Cost QuanSty t.•Pr�84 - 1�ernol#tlOn Sign-0tf/Date Remove Existing Flooring $ 120.00 4 $ 30.00 Remove Existing Washer and Dryer,to be relocated $ 30.00 1 $ 30.00 Demollt/on-Subtotel _$ 950.00;. [Framing/Hrywatt Patch and Repair Eiasbng Walls/Ceiling $ 240.00 8 $ 30.00 Materials $ 120.00 1 $ 120.00 Framig,9/Drywa#Subtotal $ _360.00 Floor Prep $ 240.00 8 $ 30.00 Install Flooring(Tile) $ 637.50 170 $ 3.75 Materials $ 255.00 1 $ 255.00 _ Flooring Subtotal $ �Pal1,732.50, n6iY ., Prime Ceiling&Walls $ 150.00 1000 $ 0.15 Paint Ceiling&Walls $ 300.00 1000 $ 0.30 Paint&Materials $ 250.00 1 $ 250.00 _ - Palating Subtotal $ .700.00 Relocate water supply and drains for washer $ 420.00 7 $ 60.00 Materials $ 100.00 1 $ 100.00 Plutnbirrg Subtotal. 520.00' LNfityrand Garage Total° $ 2,862.50 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 COpG Of VV ork - TotalCost Quantity Pnce/Each Sign-Offs Date Remove Existing Tile Flooring $ 240.00 8 $ 30.00 Remove Existing Wall Tile and Shower Pan $ 390.00 13 $ 30.00 Remove Existing Plumbing Fixtures $ 60.00 2 $ 30.00 Remove Any Damaged Gyp.Bd.After the Removal of Wall Tile Finish $ 15.00 0.5 $ 30.00 Remove Existing Vanity Cabinet $ 15.00 0.5 $ 30.00 �Frarriingl[)`rywait'�. __ Demoi11wr Subtotal $ 720.00 Patch and Repair Existing Walls due to Demolition(Allowance) $ 240.00 8 $ 30.00 Materials $ 150.00 1 $ 150.00 �FlooringMfall The rt FraminglOYm4Subtotai $ 390:00 Floor Prep $ 60.00 2 $ 30.00 Install Shower Pan Tile $ 300.00 1 $ 300.00 Install Flooring Tile $ 270.00 72 $ 3.75 Install Wall Tile $ 1,032.00 240 $ 4.30 Materials $ 996.60 1 $ 996.60 FloarftlWa6Tile Subtotal $ 2,658.60 �i?>iirttirtg T Prime Ceiling&Wails $ 30.00 1 $ 30.00 Paint Ceiling&Walls $ 128.00 160 $ 0.80 Paint&Materials $ 50.00 1 $ 50.00 Painting Subtotal $ 208.00 10 701s_-- Install Tsps Install Countertop(Sink) $ 180.00 6 $ 30.00 Materials $ 1,621.00 1 $ 1,621.00 C�lectrlcai,; _ _ Counter Too Subtotal `$ 1,801.00 Install Ceiling Light Fixtures and Switches $ 250.00 5 $ 50.00 Install Vanity Light and Switch $ 100.00 2 $ 50.00 Install New GFCI Outlets at Powder $ 100.00 2 $ °°•Jb.Qp Install New Outlets per code(2) $ 100.00 ; 9002 $ •690'00 •••• • Install New Toilet Fan and Switch $ 100.00 •• •2 $ •• 50!00 • Materials $ 708.01 •••••• 1 $ 70841 ••••i• Electrical Subtotal>$ 1,358.01 •••:•• • • • (All'(AHU) � � •••• • • • • Install Pre-Fab Concrete Slab for Condenser Unit $ 50.00 •••••• 1 $ ;••3tTfS0 ••••• Install Condenser Unit $ 100.00 2 $ ,%0,00 • • Install Air Handler Unti $ 150.00 00• • 3 $ • 90.00 Install New Ductwork and Diffusers $ 400.00 8 $ 50.60 • Install Refrigerant Piping and Condensate Drain $ 800.00 :••:•;16 $ 90.00 •° Materials $ 1,500.00 • • 1 $ :11§QQQO •••O°• ACSubfotal $ 3,p00.00`� • • • • • - - �Plumbtag I _ °°•• i •••• 0•°••� Install New Water Lines $ 360.00 6 $ •••6*0.(j0 Install New Toilet $ 120.00 2 $ 60.00 Install Faucets and Vanity Sinks $ 240.00 4 $ 60.00 Install New Shower and Tub Drain $ 240.00 4 $ 60.00 Install New Shower Manifold,Trim and Shower Head $ 240.00 4 $ 60.00 Install New Hand Held Shower Head for New Tub $ 240.00 4 $ 60.00 Install New Stand Alone Tub $ 120.00 2 $ 60.00 Materials $ 7,219.67 1 $ 7,219.67 Plumbing Subtotal $ 8,779.67 Inl�j . Install New Vanity Cabinet $ 120.00 4 $ 30.00 Install New Mirror $ 3.00 1 $ 3.00 Install Bathroom Accessories $ 9.00 3 $ 3.00 Materials $ 4,354.00 1 $ 4,354.00 Came,"Subtotal $ 4,486.00 Upstahs Bathroom Total $ 23,401.28 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL = BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence DATE: 2/11/2016 F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 Slgn-Off/Date Remove E)asting Wood Flooring $ 360.00 12 $ 30.00 Remove Existing Doors and Frames $ 30.00 1 $ 30.00 7 7- Lamirtg/bryruatt — — .,_ x _ w.e_Lrr►at1 Subtorgt '$., .';390, '' Patch and Repair All Walls $ 240.00 8 $ 30.00 Materials $ 264.00 1 $ 264.00 r -A-M-j" Floor Prep $ 480.00 16 $ 30.00 Install Wood Flooring $ 1,475.00 590 $ 2.50 Materials _ $ 1,180.00 1 $ 1,180.00 aitttlrtgr Prime Ceiling&Walls $ 330.00 2200 $ 0.15 Paint Ceiling&Walls $ 660.00 2200 $ 0.30 Paint&Materials $ 555y0.00 1 $ 550.00 I]/kf�. �ti'7f44Y. ,! Install Doors and Frames $ 720.00 24 $ 30.00 Install Baseboard $ 240.00 8 $ 30.00 Materials $ 2,2_20.00 1 $ 2,220.00 hafts Gwwof Total 8;749.00 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores,FL 33138 .i 143 1t► tc w7 ®- o -- ewSt4� � h ny Supervision $ 5,000.00 r 1 $ 5,000.00 Trash Removal and Dump Fees $ 1,830.00 1 $ •1!g9pv General Cleaning and Prep $ 1,210.00 ••• 1 $ T,2'M0 •••• • Material and Labor Transport $ 4,810.00 •• • 1 $ ",,81040 • Insurance $ 1,330.00 60••••e 1 $ i1,930& ••••i• St/p FSIOti' f T R IfOYB/z J $ 14,iSO.00 •••i•• • • • ,e a# 6060006• ..x" 51,?,., - a !' r<, '•- .. t..` x Ak. fi ;• ••••• 6060•••• 6006060 **:*s 6060 6060 00 60 00.60•• 60606000• • •• • • • • •0006060 •0060• • • • •0060060 00 • 0000 • • • 60 • ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 ` . e ® o Total Cost Quantity Price/Each Floor/ngll aterleibefell Floor Tile Powder Room $ 75.00 50 $ 1.50 Wall Tile Powder Room $ 129.60 72 $ 1.80 Wall Tile Covered Porch Entry Travertine,to Match Porch Floor $ 161.70 77 $ 2.10 Floodng Materia/sub Total,_$ 366.30 Counter To Dull Counter Top Material_and Fabrication $ 270.00 1 $ 270.00 Counter Top Sub Total $. ,. 270.00' Electrical Materiels Deta11 °, , 600w Single pole Dimmer $ 22.00 1 $ 22.00 Single Pole Lighted Switch $ 2.50 1 $ 2.50 15 Amp GFCI $ 50.36 4 $ 12.59 15-Amp Outlet and Cover Plate $ 6.90 3 $ 2.30 Exhaust Fan $ 100.00 1 $ 100.00 Powder Recessed Can Light $ 200.00 4 $ 50.00 Covered Porch Ceiling Mounted Light $ 90.00 1 $ 90.00 Misc.Electrical Materials $ 90.00 1 $ 90.00 Electrical Materials Sub Total,$ 561.76 Plur»bfrlg Materials Detail _ Vanity Sink $ 220.00 1 $ 220.00 Bathroom Sink Faucet $ 180.00 1 $ 180.00 Faucet Supply Lines $ 12.44 2 $ 6.22 Faucet Supply Valves $ 13.34 2 $ 6.67 Toilet White $ 350.00 1 $ 350.00 Toilet Supply Lines $ 6.22 1 $ 6.22 Misc.Plumbing Materials $ 400.00 1 $ 400.00 Plumbft Materiafs.Swb 7bW $ 1;182.00 • • • Dt?arpe oor and Hardware Deta/l aMaterlals $ 350.00 •• • 1 $ • 350.00 �• •• • • •••••• Wood Base Board $ 45.00 ••••• 25 $ 1•.80 Vanity Cabinet 5'-5" $ 970.00 000000 1 $ 910.00 ;••••; Powder Room Accessories:Paper Holder $ 46.00 000000 1 $ r o • • Powder Room Accessories:Towel Ring _ _-_ $ 43.20 0900 1 $ • 43.20 ••••• Carpenter ftterial SUb FotaG $ . . 1,4&.20-I •••••• •0:00 ••••• •• •• •• • •••••• Kelsey Zealy Residence .•.... .' 1399 NE 104 Street,Miami Shores,FL 33138 : • • ••••:• Y f o e o Total Cost Quarrty, Pf tce/Eacii= i••••i Din in /Master Bedroom •• • •••• • • v ., - ;. • • • Flooring Material Detail •• • Floor Tile $ 1,725.00 1150 $ 1.50 FlOnrIng A9atetlal Sub Total .$ 1,725.00 Carpentry Materials Detail Wood Base Board $ 297.00 165 $ 1.80 "_- CatpenhyMetenelSub Total $ 297.00 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL • BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 M� 3,. Total Cost Quantity Pdoe/Each - Flooring Mate»al Debit _ Master Bathroom Floor Tile $ 261.80 154 $ 1.70 Tub Wall Tile $ 204.00 80 $ 2.55 Shower Wall Tile $ 867.00 340 $ 2.55 Shower Pan Tile Mosaic $ 281.60 16 $ 17.60 Wood Flooring Plank $ 431.20 154 $ 2.80 Glue $ 140.00 1 $ 140.00 Transitional Strips $ 60.00 6 $ 10.00 Flooring Material Sub Total $ 2,245.60 Counter Top De;all Counter Top Material and Fabrication_ $ 1,350.00 1 $ 1,350.00 Counter lop Syb Total $ 1,350 00- Electrical Materials Detail 600w Single pole Dimmer $ 66.00 3 $ 22.00 Single Pole Lighted Switch $ 12.50 5 $ 2.50 15 Amp GFCI $ 25.18 2 $ 12.59 15-Amp Outlet and Cover Plate $ 9.20 4 $ 2.30 Exhaust Fan $ 100.00 1 $ 100.00 4"Recessed Can Light $ 500.00 10 $ 50.00 LED Surface Mounted Light at Closet $ 280.00 4 $ 70.00 Electric Water Heater $ 450.00 1 $ 450.00 Misc.Electrical Materials $ 200.00 1 $ 200.00 ElechVcai Mat ai1;s Seib Total`$ 1,642.88, AC Materials Detail 1.5 Tons 17 Seer Trane Unit:(Air Handler GAM5BOA18)/Condensing unit 4TTX6018) $ 5,881.00 1 $ 5,881.00 Misc.AC Materials $ 403.25 1 $ 403.25 _ AC Materiais Sub Total_ $ •6,284.25. ..•. • Plumbing:Materials Detail • • • ••9• *so*:* Vanity Sink $ 178.00 2 $ • •89.00 • 0000• • • Bathroom Sink Faucet $ 360.00 • 2 $ 11;0.00 009000 Faucet Supply Lines $ 12.44 000000 2 $ 06.22 i••••i Faucet Supply Valves $ 13.34 0"". 2 $ ...ECV • • Toilet White $ 350.00 "'• 1 $ • 350.00 • Toilet Supply Lines $ 6.22 • •••• 1 $ •••9s22 9 9..• New Tub Drain,Valve,Trim and Handheld Tub Head $ 700.00 •• •• 1 $ 9 0040 9009:0 New Soaking Tub $ 2,460.00 ••9... 1 $ 2,460.00 Shower Valve,Transfer,Pressure Balancing Valve with Lever Handle Trim $ 250.00 ; • ; 1 $ 25400 Shower Rainhead $ 220.00 9 1 $ •2"..00 Hand Shower Kit $ 160.00 • • • 1 $ 160.00 000000 Shower Pan Liner $ 55.00 1 $ •��P.GO Shower Pan Adhesive $ 7.67 1 $ " 7.67 Misc.Plumbing Materials $ 290.00 1 $ 290.00 _ Plumbing Materials Sub Total '$ 5,062.87 CarpentryMeWels Detail Minor $ 480.00 2 $ 240.00 Master Bathroom Accessories:24"Double Towel Bar $ 110.00 1 $ 110.00 Master Bathroom Accessories:Towel Ring $ 86.40 2 $ 43.20 Master Bathroom Accessories:Robe Hook $ 80.80 2 $ 40.40 Master Bathroom Accessories:Toilet Tissue Holder $ 46.00 1 $ 46.00 Master Bathroom Accessories:Glass Shelf $ 190.00 1 $ 190.00 Closet Doors and Hardware $ 620.00 2 $ 310.00 Shower Door,Glass and Hardware $ 580.00 1 $ 580.00 Attic Access Ladder $ 230.00 1 $ 230.00 Vanity Cabinets V., _ ________ _ $ 1,620.00 2 $ 810.00 _ Carpentry Material,Sub Total $ 4,043.20 ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL • BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 ® ® ® A r �$ Totg( ttst - tluantif Prk �C} " Floor Tile $ 315.00 210 $ 1.50 Backsplash Mosaic $ 960.00 50 $ 19.20 Kitchen Counter Top and Fabrication $ 3,830.00 1 $ 3,830.00 ._. CnutttttT % Spfash Sub Tvt�_;$ _ 4,ir80t10 (f+litrr±tilrtglYhtGerial4Oata11� _ Undermount Single Bowl Kltchen Sink $ 330.00 1 $ 330.00 Pull-Out Spray Kitchen Faucet $ 140.00 1 $ 140.00 SS Sink Strainers $ 49.99 1 $ 49.99 SS Garbage Disposal Rim $ 39.99 1 $ 39.99 Dishwasher Connector $ 19.99 1 $ 19.99 Faucet Supply Lines $ 12.44 2 $ 6.22 Supply Valves $ 13.34 2 $ 6.67 Garbage Disposal $ 330.00 1 $ 330.00 Disposal Power Cord $ 10.99 1 $ 10.99 P-trap&Drain Lines $ 229.999y 1 $ 29.99 Kitchen BaseWall Cabinets:White Fiat,Maple Ply.Boxes $ 14,800.00 1 $ 14,800.00 2"Brushed Aluminum Handles $ 56.00 20 $ 2.80 Wood Base Board $ 36.00 20 $ 1.80 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores,FL 33138 • •• ® ® s ® _ � z _ � ,•.,,,; 0000•• � z ,: Tod(Com#,a. §' t PrioeCh • LAufidt and are s x -"- •••rf• • 00 0000•• Floi>rJng_1N18t@llalt�etall ._- �,� _' __ ., _�._ �,.�i • Floor Tile 2 •••4• $ 01.50 • • 0000•• $ 55 00 0 '" _._ . - �. "-�iri'a�Slily TdlaF_.� _ rfp� •••• f • • • f 0000•• •f•• 00.00• 00 00 00 00 000 • •0000• • • •000.0 • • • • • 0 0000 0.8 • ULTIMATE ENVIRONMENTS, INC. 1742 COSTA DEL SOL • • BOCA RATON,FL.33432 P.561.998.3643 Kelsey Zealy Residence F.561.998.1697 1399 NE 104 Street,Miami Shores,FL 33138 MeT ,r� total Cost _ Quantity Price/Each Flooring Material Detail Floor Tile $ 122.40 72 $ 1.70 Shower Pan Tile Mosaic $ 211.20 12 $ 17.60 Wall Tile $ 510.00 200 $ 2.55 Wall Tile Accent Wall $ 153.00 60 $ 2.55 Flooring Material Sub Total $ 996.60; Counter Top Dotal! Counter Top Material and Fabrication,Caesarstone 4360 Wild Rice 2CM $ 1,621.00 1 $ 1,621.00 Counter Tajo Sub Total $ 1,621.00 Electrical Materials Detail Lutron Maestro 600w Single pole Dimmer $ 29.99 1 $ 29.99 Lutron Decora Single Pole Lighted Switch $ 15.84 2 $ 7.92 Leviton 15-Amo White Smartlock Pro GFCI $ 25.18 2 $ 12.59 Leviton 15-Amp White Decora Outlet and Cover Plate $ 7.00 2 $ 3.50 Powder Exhaust Fan $ 100.00 1 $ 100.00 Vanity Lights(Allowance) $ 240.00 2 $ 120.00 Recessed Can Light(Allowance) $ 200.00 4 $ 50.00 Misc.Electrical Materials $ 90.00 1 $ 90.00 Ell Materials Sub Taal $ 708.01 Plumbing Materials-DOWN- Vanity OWN_Vanity Sink Verticyl Rectangular Undermount Sink(K2882-0) $ 248.00 2 $ 124.00 Vanity Sink Brizo D6638OLFBNLHP Sidema Faucet Body $ 844.00 2 $ 422.00 Faucet Supply Lines $ 12.44 2 $ 6.22 Faucet Supply Valves $ 13.34 2 $ 6.67 Kohler Persuade Two Piece Toilet Elongated Bowl,White(K4353-0/K4442-0) $ 439.00 1 $ 439.00 Toilet Supply Lines $ 6.22 1 $ 6.22 New Tub Drain,Valve,Trim and Handheld Tub Head(KT97328-4,K97339 and VSPECAP $ 1,459.00 1 $ -64`x00 Victoria&Albert VEDGNSW Edge 59 by 31 Soaking Tub(VIOSNSW) $ 522.00 • • 1 $ ••Wo •••••• Brizo(DT60280BN)Sidema Shower Faucet Trim Kit $ 3,320.00 • • • 1 $ 1,320.00 • Delta Faucet(DR60000UNWS)Shower Rough In Valve $ 59.00 •• • 1 $ i••5900 •• Ebbe America(EE4404/EE4400),4"Square Drain Grate and Body $ 34.00 •••:•• 1 $ • ".00 •••••• Shower Pan Liner $ 55.00 •••••• 1 $ 35.00 •••• Shower Pan Adhesive $ 7.67 •••••• 1 $ •••'WV • • Misc.Plumbing Materials $ 200.00 •••• 1 $ • 200.00 ••+•• Phl"hVMaI+ do;SUB Total:$ 7.219.67 •••••• •••• •••••• •• •• •• • •••••• GarperltrY Materials Detail`. " •••••• • •• Mirror $ 300.00 • 1 $ • 30400 .... • Vanity Cabinet 6'Floating Vanity White Lacquer Finish $ 3,358.00 1 $ •8808.80 Bathroom Accessories,Paper Tissue Holder Brizo(D695080BN)Sidema $ 118.00 : ••• 1 $ • 118.00 :••••: Bathroom Accessories,Robe Hook Brizo(1369358013N)Sidema $ 142.00 •• • 1 $ .*1:2.00 • • Bathroom Accessories,Towel Bar Brizo(D692480BN)Sidema $ 318.00 2 $ •159.00 Bathroom Accessories,Towel Ring Brizo(D6946806N)Sidema $ 118.00 1 $ 118.00 Carpentry Material Sub.TotW ,$ 4,354.00 Kelsey Zealy Residence 1399 NE 104 Street,Miami Shores,FL 33138 a I t ® ® ® : Total Cost c uankty. t?i,WEarh,, General upstairs Flooring Material Detai! Wood Flooring $ 1,180.00 590 $ 2.00 Flooring Materia/Sub Total $ 1,180.00 Carpentry Materials Detail_. Doors and Hardware $ 1,860.00 6 $ 310.00 Wood Base Board $ 360.00 200 $ 1.80 Ca pentryMaterial Sub Tofai_:$ 2,224.00