RC-15-1257 (3) t
r
teri�'fite doctor
7351 NW Vh STREET UNIT V
MIAMI,FLORIDA 33126
305-442-9988
305-442-0594 FAX
FL State Lic.#JF161788
Certificate of Compliance for Termite Protection
(As required by Florida Building Code(FBC) 1816.1.7)
Treatment Date: 10/27/2015
Lot/Block#
Address: 1470 NE 101 STREET
NHANII SHORES,FL
Requested by: SOUTHERN LAND CONSTRUCTION
Compaction done by:
Chemical used: Demon Max
Percent Concentration: 1.0%Rate As Per Label
Area treated(square feet) 250 SO FEET
Linear feet treated:
EPA Reg.No. 100-1218
GUARANTEE:
One free year of guarantee for treatment only will be done if subterranean termites are
verified N.B.If there is any modification to the structure or flooding of any kind,the
guarantee is void.
if pretreatment is done for additions only,only the treated areas will fall under this
guarantee.
This guarantee does not cover damages caused by water or termite damages to structure or
contents.
At the end of this initial free year the Customer may purchased annual renewals at the rate
of$50.00 for one thousand square feet or less providing each is received within 30 days
prior to the due date. Treatment is in accordance with rules and laws established by the
Flo ' a bDepartment of A re and Consumer Services
Applicat
Customer's Signature:
Date: 10/27/2015
C Y
may.* c ALL STATE ENGINEERING AND TESTING CONSULTANTS, INC.
ALL 1 P�ITE TESTING LABORATORIES-ENGINEERS-INSPECTION SERVICES-CHEMIST-DRILLING-ENVIROMENTAL SERVICES
ENGINEERING 12949 West Okeechobee Road,Unit C-4,Hialeah Gardens,Florida 33018-Phone: 305-888-3373 Fax:305-888-7443
PROCTOR COMPACTION TEST
ASTM D-1557
Date October 27�_,2015 Order Number 15-353
Client Southerland Construction
Address 15830 SW 1051 Avenue,Miami,Florida 33157
Pro'ect "SFR"
Address 1460 NE 101st Street, Miami Shores,Florida
Sam le Location Stock ile at the job site
Soil Descri tion Subgrade: Sand with Some Coral Rock Mix
Sam led b Malick Re orted to
TEST RESULTS
Laborato Number: 15-354 Sample Number: 02
The following compaction test was conducted in accordance with the standard methods for Moisture/Density relations of soil using a 1016.Hammer and 18"drop
A-ASHTO designation T-180-C.
%Moisture Dry Density Dry,ppnshvs ,'A Mods#ure
9.9 100.3 5 6 7 8 9 14 15 16 17
12.9 103.1 AV
14.3 104.3
103.3
Optimum Moisture 14.3
100%Max,Dry Density 104.3
----------
98%Dry Density 102.2
95%Dry Density 99 N
Gradation test passing 3/4"Sieve 98.50% Z
W
Sampled By Malick
Tested By SS
T T
Checked By ISS
Typed By we % MOISTURE
Respec Hy- uljimitted by,
U0 2201
Gil avarrete,P.E. #51371
ALL STATE ENGINEERING&
TESTING CONSULTANTS, INC.
Should any subsoil conditions in the property(area)tested be found different from those encountered on the tested Locations reported on our Density Test
All State Engineering&testing Consultants Inc is not to be held responsible
Asa mutual protection to client,the public and ourselves,all reports are submitted as the confidential property of clients,and authorization for publication of
statements,conclusions or extracts from our reports is reserved.
ALL STATE ENGINEERING AND TESTING CONSULTANTS, INC.
ALL STATE TESTING LABORATORIES-ENGINEERS-INSPECTION SERVICES-CHEMIST-DRILLING-ENVIROMENTAL SERVICES
ENGINEERING 12949 West Okeechobee Road,Unit C-4,Hialeah Gardens,Florida 33018-Phone: 305-888-3373 Fax:305-888-7443
Field Density Test of Compacted Soils
ASTM D-5195
FProAdcdress:
ent: Southerland Construction Order# 15-353
dress: 15830 SW 105` Avenue,Miami,Florida 33157 Date: 10-27-15
'et. "SFR" Gau e# 23599
1460 NE 101 ` Street,Miami Shores,Florida
Phone No:
Attention:
LabID
5-1951 Inside of Garage South Side Slab on Grade NE Area
# Location
1
15-1952 Inside of Garage South Side Slab on Grade Center Area
15-1953 Inside of Garage South Side Slab on Grade SW Area
Descri tion o Material Sand with Some Coral Rock Mix
Back Fill Sub grade x Base rock
Sam led B : TestedB--
Laboratory Identification Number 15-1951 15-1952 15-1953
Test Number 4 5 6
Depth in Inches 12" 12" 12"
T -i
Field Density LB/Cu Ft. (Dry Density) 102.9 103.2 102.7
Moisture Contents 10.2 10.8 10.5
Maximum Density In the Field(%) 98.7 99.0 98.5
Compaction Requirement by Specs %of 98% 98%o 98%
Maximum Density
100%Maximum Density (Lab) 104.3 104.3 04.3ProctorT-180AASHTOMethodC 15-354 �1[
5-354
Optimum Moisture(%) q14.3ReportedBy Checked By Typed By
Respect miffed by,
cD�JF. °
NO 0 2 His
Gilberto Gavarrete,P.E. #51371
ALL STATE ENGINEERING &
TESTING CONSULTANTS,INC.
should any subsoil conditions in the property(area)tested be found different from those encountered on the tested locations reported on our Density
Test All State Engineering&testing Consultants Inc is not to be held responsible
Asa mutual protection to client,the public and ourselves,ail reports are submitted as the confidential property of clients,and authonzahon for pubhcat�on of
statements,conclusions or extracts from our reports is reserved.
STRIJCTURES INTERNATIONAL, INC.
R66
Consulting
Structural Engineers
February 11,2016 es7
Reference: 1460 NE 101 Street
Miami Shores,FL 33138
Dear Building Official:
This office has confirmed that the work in the detail enclosed, dated 1015/15, has been
completed. The work is approved by this office.
Please call this office should you have any questions.
,`111111111j1
b '- F� 1
Su
••oyn31
c.
= Z 96
er ,Ph.DQ-Y.--E.
gi Princl 1 •�4
FL ► "NAL %`%
15-070 ��''•11�'''�
7501 Wiles Road,Suite 106-B,Coral Springs,FL 33067 CA#9446
Phone:(954)227-1512 Fax:(954)227-6633
r i
,STRUCTURES INTERNATIONAL, INC.
Iff�q Consulting
�� Structural Engineers
STRUCTURES INTERNATIONAL, INC. PROJECT No. /3-0W
CONSULTMG STRUCTURAL EMN3&M PAGE No. I of I
PROJECT: I1140 NE !pi STPARST CALL.BY:4PL
CALL.DATE: SC 131 WC
SUBJECT: _avw L6Gd_ CHK.BY:
CHK.DATE:
/t7—
-
ms1
i
r
_. -------------.__.. .....___
i
G
i
7501 Wiles Road,Suite 106-13,Coral Springs,FL 33067 CA#9446
Phone:(954)227-1512 Fax:(954)227-6633
STRUCTURES INTERNATIONAL, INC.
Consulting
Structural Engineers
frN
u
e� r
7501 Wiles Road,Suite 106-13,Coral Springs,FL 33067 CA#9446
Phone:(954)227-1512 Fax:(954)227-6633
STRUCTURES INTERNATIONAL, INC.
Consulting
Structural Engineers
a
i►
3��f
I it
7501 Wiles Road,Suite 106-13,Coral Springs,FL 33067 CA#9446
Phone:(954)227-1512 Fax:(954)227-6633
Knauf Jet Stream® 73.3
Blowing Insulation kNAU[INSULATIRN
-7
A?-C--,e
Equipment Required
To achieve labeled R value,this product must be applied with a pneumatic blowing machine and a corrugated hose
Batts and Blankets with a minimum.251 internal corrugation,a rdhimurn length of 150 ft.and a diameter of at least 3".Cogs in the hose
When installed in acmithince with the manufacturer's should not be less than 38-in diameter.Acceptable material feed rate is 5-35 lbsJmInute.Recommended feed rate
recommendations,Knauf baths and blankets will is 15-25 Wminute.
provide the full R-value.
Thermal Performance(Attic Application)
The stated them
I resistance(R-value)is provided by installing in accordance with the manufacturer's instructions,
the required number of bags per 1,000 sq.&of net area,at not less than the labeled minimum thickness.Failure to
To obtain an Installed Insulation install both the required number of bags and at least the rniffirrium thickness will result in lower insulation R-value.
insulation resistance should not be
(R-Value)ot. less than:
R-38HD 10.25'
R-38 12,00"
R-30HD 8.25' The of bailer The wa*m of
To Obtain 1,MsFoludam C=Wrft of 11ft bag kwMm
R-30 10.00" 11-106-reserI dOW not be 511001 rMl CW#W should rimbe shmititiMbe f SIMW rM to
R-26 9.00" (R-Value)of: tm ftm* more"W.- less OW: less titan: las em
,
R-22 6,50" R-60 29.7 33.6 SF .952 lbs, 19,750' 19.750"
R-21HD 5.50° R49 23.5 42.5 SF .753 lbs. 16.375" 16,375'
R-19 6.25- R-44 .670 lbs,
209 47.8 SF 14,875' 14.879"
R-15HD 3.50" R-38 1-7.8 56.2 SF .569 lbs. 13.000" 13.000'
R-13 3.50" ----
R-11 3.50" -
R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375"
R-26 11.8 8U SF .377 lbs. 9,125' 9.125"
R-8 2.50' ----
R-18 m a 5Y cawly Confomm to ASTIJ C E-55 acl Fe-:tev R-22 9.8 102.2 SF .313 lbs. 7.750. 7.750'
Specftation HH-4-5211F.
R-1-9 I 8.4 1 119.3 SF .268 lbs. 1 6.750 6.750"
Framing Adjustment
R-13 5.7 175.3 SF .183 lbs. 4.750' 4.750'
-- -
To compensate for framing members,the number of R-11 4,7 210.8 SF .152 lbs. 4.000' 4.000'
bags per 1,000 sq.ft.of area to be insulated should be Bag WW&9N--Nw,"a�32 lbs.,Unurun 31 IDs.
as shown below. Coverage ard mstaF,aton data were den mw*d Lsng a W-Matic*If b4�irqnnac"ezn trrd par wl,Ih 13'gabe apenirg.210 0 air pmsuv&�d
,-,
This pmduct=ftm W we perbmwm reT.Awn of AS17A C 764.Type 1.and icermd Federg Specification K-1-1-10308.Type 1.Ctass B
Bags/MSF Bags/MSF R-vatues are deWaOW in acowdanu wilt 687 and C 518.
Joist 16"O.C. 24"O.C. --W reals resLqW=to ileal,ft=The h9W ft R-vWw the T-eater ft L=6"P=W,To get the marked R-r,W.it is eswbW that M*
R-Value,Dimensions Framing Framing imu%Von be inzWW pW%Iy.'f yet do C yourself.get 1pstrwWns wW Ww ftm camWy.bubo==do not Ix m mb 11m package.- - liased on Th.M"2-year m0rV sandy.r*Veftmd wWneqt air 201m p--nW wmM be I percem or lem.I'm amort semng is
2-x A -12 31.3 ft�msqffcar�-nreetre.
2x431.29M seMO�m are effecwey the same-
R-60 2x6 30.8 31.1 VoWAM11 is a nVi5L-red rddem. rk cO Ulnisu!.
W 30.5 30.8
2x4 24.8 24.9 Builder's Insulation Statement
R-49 2x6 24.4 24.7 Batts and/or blankets have been installed in conformance with the above recommendations to provide a thermal
W 24.5 --24-.5 resistance Of...
2x4 21.5 21-.7 R-Value Thickness
R-44 2x6 21.2 21.5
W 20.9 21.2 Attic Area R- at _/=Inches
2x4 18.4 18.6 Sloped Ceilings R- at Inches
R-38 2x6 18.1 i8.4 Walls R- at Inches
2x8 17.8 18.2
2A 13.8 18.2 (over an unheated crawl space) R- at Inches
R-30 2x6 13.5 13.8 Crawl Space Perimeter R- at Inches
W 13.3 13.6
2x4 11.9 12.0 Date installed
R-26 24 11.6 11.8 Blown insulation has been i:J211ed In co ormance with the above recommendations to pr ride an
W 11.3 11.6 R-value of:R- 30 using ba of this insulation to cover
2A 9.9 10.1 square feet 4 e of I Q inches.
R-22 2x6 9.7 9.9
W 9.4 9.7
2x4 8.5 8.6 InsulaCon"WI(signature)
R-19 2x6 8.2 8.4
W 7.9 8.2 CompanyDate
2x4 -5.6 [---5..-8--
R-1 3 2x6 5.4 5.6 "oM-ew
W 5.1 5.4
20 4.6 4.7
CompanyDate
R-11 2x6 4.3 4.5
W 4.1 4.3 The coverage information on this attic card applies to the entire United States(including Minnesota).
wwwAnaullinsulation.us Knauf Insulation GmbH One Knauf Drive,Shekde.IN 46176 Tel:(800)8254434 ext.8300 FAX:(317)39&3675
@ 2007 Knauf Insulation GmbH.
� � COI
M Gmaol
RC15-1257:Wood Cladding and Pool Deck
michael jeer<mikellopis@gmail.com> 7 de junio de 2016,17:1e
Para: on a lv i(0l @g i mires village.com
Cc:ogoncalves0l�mail.com
Hi Ismael, r"
Pursuant to our meeting this morning. See snap shots from the permit approved plans for the project at 1460 NE 101 St.
1. The plans indicate"new finish to be selected by owner on existing vertical element'we are planning on installing same wood cladding as 1421 and 1391. Do we need to
submit a revision for that if its already on plan?
NEW FINISH TO BE SELECTED
BY OWNER ON EXISTING
VERTICAL ELEMENT.-----\
7-7
---- --------- --
--r
B B B B
Bt
2. The plans indicate"existing concrete deck with new finish selected by owner" the intent was always to install combination of wood and stone finish which is exactly what
we did but the pattern is different than indicated on plan. Is a revision going to be required for this?
U `
EXIST.POOL
1V-10" sr-10"
V_EXISTING CONC. DECKWITH
NEW FINISH TO BE SELECTED
BY OWNER.
Cordially,
Michael Jaar
Coll 786-252-6374
-- ,JVF, Y
;EP 0 9 2015
Subsoil Investigation Report
prepared by:
i
e era
& TESTING INC. www.ted-eng.( I
r
1
N
Client: Oscar Goncalves
Contact: J. Ruben Jimenez
i
Address: 1460 NE 101 st Street
i.
Miami Shores, FL 33138
l
1
;i Project: Proposed Renovation & Foundation
Address: 1460 NE 101 st Street
. t ► Miami Shores, FL 33138
Date: Tuesday, August 11, 2015
t I i
eotechnical Materials Testing Inspections ( Environmental
Phone 954-784-2941
J.
800-848-1919 ederal
& TESTING INC. Fax 954-784-7$75
250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.com
Table of Contents
ClientInformation ------------------------------------------------------------------------ pg. 1
Project Information ---------------------------------------------------------------------- pg. 1
General Soil Descriptions -------------------------------------------------------------- pg. 1
Foundation Recommendations ------------------------------------------------------- pg 2
SoilParameters ----------------------------------------------------------------------- pg. 3
Excavations ------------------------------------------------------------------------------- pg. 3
Settlement --------------------------------------------------------------------------------- pg. 4
Grading ----------------------------------------------------------------------------------- pg. 4
Appendices -------------------------------------------------------------------------------- pg. 5
Soil Boring Log(s)
Project Location
Soil Boring Location(s)
Soil Classifications
Sampling Procedures
Limitations of Liability
For Your Information
Our findings in this report are based on soil conditions encountered in the test bore locations only, proposed structure to
be built, (if available at this stage),Florida Building Code requirements and standard engineering practices. If your report
is preliminary (i.e. vacant land or building to be demolished) additional borings are required within the foot print of the
proposed structure once the location&layout of the proposed structure is known.
Please read this report in its entirety and follow all recommendations. Failure to do so may result in the permitting
agency (Building Department, etc.) withholding the Certificate of Occupancy. This will cause delays and additional
costs. The Permitting Agency will require a final certification or signing off of the project prior to issuing the Certificate
of Occupancy. All of our recommendations need to be followed to receive a final certification from F.E.T., including
densities on each lift,demucking verification,piling inspection,etc.,whichever recommendation applies to your project.
Please schedule us at least 24 hours in advance for all tests and inspections. If you choose to use another Engineering
Firm, you must verify they yvill grovioe you with tip proper certification in writing, as outlined in our report. Our firm
will only provide a certification lgtttti f iE has;ve:i$ed all work as recommended in our report.
. 11: • • • • ••• .
•• ••• •• • • • ••
. ••• •• . •• .
. . :11. • . •. • •
.. . . . . . . . . .
. •• . • . • . • . •
• • • • 0 MIAMFDADB
Construction Material •:• :• •: •44mefiea n poncreke Miami Dade Florida Department
Engineering Council Institute County of Transportation
Phone 954-784-2941
ederaG800-848-1919
:UJRW&TESTING INC. Fax 954-784-7875
250 SW 13th Ave Pompano Beach,FL 33069 fed-en .00171
Tuesday,August 11,2015 Job Order Number 15-SB-269
Oscar Goncalves
1460 NE 101st Street
Miami Shores,FL 33138
Attn.: J.Ruben Jimenez
RE: Subsoil Investigation
Proposed Renovation&Foundation
1460 NE 101 st Street
Miami Shores,FL 33138
Dear Sirs:
Pursuant to your request,Federal Engineering&Testing,Inc.has completed a subsoil investigation on 08/05/2015 at the
above referenced site. The purpose of our investigation was to verify subsoil conditions relative to foundation
preparation and design.
A total of one (1) SPT boring was performed according to ASTM D-1586 drilled down to a depth of twenty-five feet
(25) below the existing ground surface. (See attached field sketch for locations). The following is a general description
of soil stratas for the subject site:
From
Depth To Description of Soils
0" 4" Concrete
4" 6'6" Pale Brown Sand with Rock
616" 8' Marl
8' 10' Sand with Organics
10' 14' Gray Sand with Rock& Silt
14' 25' Limerock
Groundwater table elevation was measured immediately at the completion of the boring and was found at a depth of 4'6"
below existing ground surface. Fluctuation in water level should be anticipated due to seasonal variations and run off as
well as varying ground elevatiep,4,rvps4Ncttoi= imatering and pumping activities in the area. Site contractor must
familiarize himself with sate conlitift 3n:t%lv&t groundwater controls and dewatering is needed. Surface flooding
may result under hurricane contift AR**annd'sheu;d be taken into consideration in the design of the project. The contractor
shall make sure that groundwater levels on adjacent properties are not affected by the contractors dewatering activities.
Specialty groundwater cAUrAors sUAN W gonsultd-d,tbr all work below the groundwater level.
. . .. . . .. . .
••• • • • • •
• • • • • • • • • •
• •• ••
0.11
• • •• ••
Tuesday,August 11,2015
1460 NE 101 st Street
Miami Shores,FL 33138
Page 2
The boring log(s) attached present a detailed description of the soils encountered at the location. The soil stratification
shown on the boring log(s) is based on the examination of the recovered soil samples and interpretation of the driller's
field log(s). It indicates only the approximate boundaries between soil types. The actual transitions between adjacent
soil types may be gradual.
From a geotechnical engineering perspective, the site is suitable for the construction of the proposed structure,provided
that the surface sand layers are compacted in place and proof rolled. Localized areas of loose materials, if present, will
become evident during site clearing,grubbing and proof rolling,and must be removed prior to filling operations.
Based on our understanding of the proposed structure and the information obtained from our field boring log(s); we
recommend the following procedures for foundation design:
1) Strip the entire footings and building construction areas of topsoil and ground vegetation (when encountered)
down to clean granular material. Any underground structures, utility lines, root systems and drainage trenches,
etc.must be removed in their entirety from beneath the proposed construction areas.
2) Saturate and compact all construction areas with a heavy self propelled vibratory compactor to a minimum of
95%of the ASTM D-1557 modified proctor method.
3) Care should be taken when using vibration in case of existing structures in the vicinity of the construction area.
If vibration cannot be used for compaction, static compaction may be applied. However, in this case, the
compacted layer should not exceed 6 inches in thickness.
4) Backfill construction areas to proper elevation if needed using a clean granular material placed in lifts not to
exceed twelve(12)inches in thickness and compacted as per item 2.
5) Representative samples of the on-site and proposed fill material should be collected and tested to determine the
classification and compaction characteristics.
6) All construction fill material above the water table shall be clean granular soil, free of organics or other
deleterious material, and shall contain no more than twelve (12) percent fines passing a U.S. Standard No. 200
sieve(0.075mm) and have a Unified Soil Classification(USCS) designation of GP, GW, GP-GM, GW-GM, SP
or SW. No particle size greater than three(3)inches shall be used in the top 12 inches of the building pad.
7) Fill Material below the water table shall be washed free draining gravel such as FDOT No. 57 stone or
equivalent to aboxb 1.2r�ritgs jbQv; tie.vmter table unless dewatering is used. When dewatering is used, fill
material shall be clears krar'M1at soit,.free.of organics or other deleterious material, and shall contain no more
than twelve(12)p4rcenkl s passing;15.4Standard No.200 sieve(0.075mm).
. ... .. . .. .
. . . . .. . .
.. . . . . . . . . . . .
. .. . . . . Go* 969
... . . . . ... . .
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Tuesday,August 11,2015
1460 NE 101st Street
Miami Shores.FL 33138
Page 3
8) Verify all densification procedures by taking an adequate number of field density tests in each layer of
compacted material. Density tests shall be performed on the slab areas, footing areas, interior bearing wall
footings and column pad footings. This must be scheduled immediately after Tamp and Spray and/or
Compaction,but before Reinforcing Steel Placement. If reinforcing steel is already in-place, it must be removed
from all areas to be tested prior to performing densities.
9) After the installation of any plumbing and electrical piping; we recommend that the disturbed area be
recompacted and additional densities tests be performed to verify proper compaction of the disturbed areas.
10) All of the above Geotechnical work shall be performed under the supervision of Federal Engineering &
Testing's geotechnical engineer or his representative to verify compliance with our specifications and the
Florida Building Code. Please call us at 954-784-2941 for scheduling.
11) In the event of existing structures, existing footings or proposed drainage lines,provisions shall be made by the
structural engineer and site contractor to protect all footings from undermining and exposure. The geotechnical
engineer shall be notified of these conditions to evaluate the applicability of his recommendations.
The above foundation recommendations being achieved and verified; it is our opinion that the proposed structure be
designed for a shallow foundation system with a permissible soil bearing capacity not to exceed 350 P.S.F. Building pad
certification requires satisfactory completion and verification of all the above foundation recommendations.
Provisions shall be made by the architect, engineer of record and contractor to address differential settlements when
tying in new to existing structures due to the presence of the layers of Marl and Sand with Organics found below the
proposed renovations. Mixing of different foundation types shall not be used unless provided with expansion joints to
address differential settlement.
Slabs placed upon compacted fill may be designed using a modulus of subgrade reaction value of 200 pci. The following
soil parameters shall be used for retaining wall designs:
• Soil unit weight moist-------------------------------------------------------------------------- 110 pcf
• Soil unit weight buoyant------------------------------------------------------------------------ 60 pcf
• Angle of internal friction----------------------------------------------------------------------- 300
• Active Earth pressure coefficient (Ka)—--------------------------------------------------• 0.33
• Passive Earth pressure coefficient (Kp)---------------------------------------------------• 3.0
• Angle of wall friction for steel piles--------------------------------------------------------- 300
•Angle of wall fnc &for•conoce;e f Finck walls------------------------------------------- 200
0000 . . .
• Angle of wail.fritiob i)r:utccdaNd steel--------------------------------------------------• 15°
.. 000 .. . . . ..
Excavations shall not extend within one (1) foot of the angle of repose next to existing footings or structures unless
underpinned. Trenchiog•sh$11 be;jn Aplia:we :vijh the Florida Building Code, OSHA and Trench Safety Act
requirements. Shoring 0* iall0 c�e9igne;�and inspec;�a by a Florida licensed professional engineer.
. .
. . . .0 0.0. . . . .
. .. .. . . . :0
. ..
0000 . . ... . .
Tuesday,August 11,2015
1460 NE 101st Street
Miami Shores,FL 33138
Page 4
All outside ground surfaces must be sloped away from the structure to avoid water accumulation and ponding. All rain
waters shall be discharged away from all building foundations. Verify all water,sewer,plumbing, sprinkler and drainage
lines are properly functioning with no leaks in the vicinity of the foundation.
Regardless of the thoroughness of a geotechnical exploration, there is always the possibility that conditions may be
different from those of the test locations; therefore, Federal Engineering & Testing, Inc. does not guarantee any subsoil
condition between the bore test holes. A site plan showing the location of the proposed structure was not provided at the
time the soil borings were performed. For a more accurate portrayal of subsurface conditions,the site contractor should
perform test pits. If different conditions are encountered,Federal Engineering&Testing Inc., shall be notified to review
the findings and make any recommendations as needed. In accepting this report the client understands that all data from
the soil borings is intended for foundation analysis only and is not to be used for excavating, backfilling or pricing
estimates. The site contractor must familiarize themselves with the job site conditions.
Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is
required, we can provide a proposal for performing an environmental analysis of the soil materials. For Environmental
due diligence,a Phase I and/or Phase II Environmental Site Assessment is recommended.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of
clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved
pending our written approval.
Federal Engineering & Testing, Inc. appreciates the opportunity to be of service to you at this phase of your project.
Please feel free to contact us if we may be of further service to you.
Sincerely,
Keith LeBlanc,P.E. 8/0 rAr
Federal Engineering&Testing,Inc.
Florida Reg.No. 59394
Certificate of Authorization#5471
.. ... . . . . . ..
. .. . . . . ... .
• . • • . . . •
.. ... .. . . . ..
. 0:0 •• . •• .
:11. . . .. . .
.. . . . . . . . . .
. •• . • . • . • . •
*:0 . . . . 0:0 .
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Tuesday,August 11,2015
1460 NE 101st Street
Miami Shores,FL 33138
Page 5
Appendices
I
Y• ••• • • • • • ••
• •• • • • • ••• •
•• ••• •• • • • ••
• • •• • • •• • •
•• • • • • • • • • • • •
• •• • • • • • • • •
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
edera Phone 954-784-2941
800-848-1919
& TESTING INC. Fax 954-784-7875
250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.com
SPT Test Boring Report
Client: Oscar Goncalves Date of Test: August 5,2015
Project: Proposed Renovation&Foundation Hole No.: B-1
Address: 1460 NE 101st Street Location: See Attached Drawing
Miami Shores,FL 33138
Depth(FT) Soil Descriptions [Hammer Blows "N"
1 0"-4" Concrete A g
20
2 12 14
3 4"-6'6" Pale Brown Sand with Rock 13 11 19
4 8 7
5 5 4 6
6 6'6"-8' Marl 2 1
7 2 1 3
9 8'- 10' Sand with Organics 1 2
10 1 1 1 3
11 10'- 14' Gray Sand with Rock&Silt A A A
12 A A
13 A A A
14 A A
15 13 13 27
16 14 15
17 A A A
18 A A
19 14'-25' Limerock A A A
20 A A
21 19 17 35
22 18 20
23 A A A
24 A A
25 A A
26
27
28 •• ••• . . • . • ••
29
30
•• • • • • • • • • • • •
• •• • • • • • • • •
Water Level: • 416" • Below Land Surface Keith LeBlanc,P.E.
••. • • • • ••r • • Federal Engineering&Testing,Inc.
4;4191?; • : Florida Reg.No.59394
••• • • • ••• • • Certificate of Authorization#5471
�loll�alo
NE-Q�u ays1d%T-errece--
A 40
Toower5,de�e pace_
`1y
lVEa1051NSt
. f,N '- or 'post
r aM
ff tibololifropip -sip
ritR
NEA rd•St _
r `� r� •'t Viz+ +lr, �� � � �'7 �1
^l
E=102nd-St
' „ 6 , . site Location
f4
-- NE 101•s' s•.�.
f Z �..
mW
y w it
th-St
i1't � a
elt Ago-!4 ak
V�RM
4►�Nt" +'► 40V C 2015 Google
1 1 1
Federal ♦ T&Ud Pompano Beach, 1 1 • . 784-2941
Client: Oscar Goncalves Project: Proposed Renovation i Foundation
Subsoil InvestigaSIft • ect Address: 460 NE 10
/ is notAzle Miami Shores, 33138
N
O -
e �
s
t � oO � U�t:7lS�
1
� J
141
•• ••• • • • • • ••
..' •• •• Soil $orhi Location Map
Federal En ineeiin & T&U ?nc•2fO;S�713th AVE Pompano Beach, FL 33069(954) 784-2941
Client: Oscar Goncalves Project: Proposed Renovation&Foundation
Test: Subsoil Investigation ':• Project Address: 1460 NE 101st Street
(site map is not to scale)• •; ;•••; Miami Shores,FL 33138
Soil Classifications
Correlation of Penetration Resistance with Relative Density and Consistency
Sands
Dynamic Cone Penetrometer Standard Penetration Relative Density
Penetrometer Resistance Hammer Blows
0- 10 0-4 Very Loose
11 -25 5 - 10 Loose
26 -45 11 -20 Firm
45 -75 21 -30 Very Firm
76-120 31 -50 Dense
> 120 >50— Very Dense
Silts&Clay
Dynamic Cone Penetrometer Standard Penetration Relative Density
Penetrometer Resistance Hammer Blows
0 -6 0-2 Very Soft
7- 15 3 -5 Soft
16-30 6- 10 Firm
31 -45 11 - 15 Stiff
46-90 16-30 Very Stiff
91 - 150 31-50 Hard
Rock Hardness Description
Soft Rock core crumbles when handled
Medium Can break core with your hands
Moderately Hard Thin edges of rock core can be broken with fingers
Hard Thin edges of rock core cannot be broken with fingers
Very Hard Rock core rings when struck with a hammer
Sand Quantity Modifiers Particle Size
Very Slight Trace 0 -2 % Boulder > 12 in
Slight Trace 2-5 % Cobble 3 - 12 in
Trace 5 - 10 % Gravel 4.76 mm-3 in
Little Trace 10- 15 % Sand 0.074 mm-4.76 mm
Some .. ...15 -13 0/ Silt 0.005 mm-0.074 mm
With .; ? 3/0: :•• Clay <0.005 mm
Silt-Clay Quan 'ty M yrs .'.
Slightly Silty/Claydy . . Q b o • • '
Silty/Clayey 5 -030010 '
Very Silty/Clayey 30-50%
... . . . . ... . •
Drilling & Sampling Procedures
The soil borings were installed in accordance with Standard Penetration Tests procedures as set forth in ASTM D-1586.
Representative samples were collected utilizing spilt-barrel techniques in accordance with the procedures set forth in
"Penetration Tests and Spilt-Barrel Sampling of Soil in ASTM D-1586. The following field tests, measurements and
laboratory analysis were performed/collected during the installation of each soil boring.
Penetration Tests
During the sampling procedures, Standard Penetration Tests were performed at five (5) foot intervals to obtain the
standard penetration value (l) of the subsurface soil. The standard penetration value(N) is identified as the number of
blows of a 140-pound hammer falling thirty(30)inches,required to advance the spilt-barrel sampler one(1) foot into the
subsurface soil. The sampler was lower into the bottom of the previously cleaned drill hole and advanced by blows from
the hammer. The number of blows was recorded for each of the three (3) successive increments of six (6) inches
penetration. The"N"value is obtained by adding the second and third incremental numbers.
Water Level Measurements
Water Level depths were obtained during the test boring operations. In relatively pervious soils, such as sandy soils,the
indicated depths are usually reliable groundwater levels. Seasonal variations,tidal conditions,temperature, land-use and
recent rainfall conditions may influence the depths to groundwater levels.
Soil Properties/Classification
All samples collected were classified in accordance with the Unified Soil Classification System criteria to determined
soil material properties and compared with published literature of the USDA Soil Conservation Survey of Broward
County.
Ground Surface Elevations
Ground surface elevations have not been provided for the proposed boring locations. Therefore, all references to depth
of the various strata and materials encountered were from existing grade at the time of the drilling operations.
.. ... . . . . . ..
•• . . . . •
• . • •
.. ... .. . . . ..
. •.• •• . •• .
.. • • . • O . • ; t t t
•• . • • . 0
:0:. . . . . . . . .
• • • . . •• .:
0:, .• •. . ... 0
i
Limitations of Liability
Warranty Analysis and Recommendations cont.
We warrant that the services performed by Federal Engineering and Testing, In accepting this report the client understands that all data from the soil boring
Inc.(F.E.T.) are conducted in a manner consistent with the level of skill and is intended for foundation analysis only and is not to be used for excavating,
care ordinarily exercised by members of the profession currently practicing backfilling or pricing estimates.In accepting this report the client understands
under similar conditions. No other warranties, expressed or implied, are that all data from the soil boring is intended for foundation analysis only and
made. While the services of F.E.T. are an integral and valuable part of the is not to be used for excavating, backfilling or pricing estimates. The site
design and construction process,we do not warrant,guarantee,or insure the contractor must familiarize themselves with the job site conditions. Soil
quality or completeness of services or satisfactory performance provided by boring(s) on unmarked vacant property or existing structure(s) to be
other members of the construction process and/or the construction plans and demolished is considered preliminary with further boring(s)to be performed
specifications which we have not prepared,nor the ultimate performance of after proposed building pad is staked out.Report recommendations are based
building site materials. As mutual protection to clients, the public and primarily on data from test borings made at the locations shown on the test
ourselves,all reports are submitted as the confidential property of clients,and boring reports. Soil variations may exist between borings and may not
authorization for publication of statements, conclusions or extracts from or become evident until construction. If variations are then noted, F.E.T. must
regarding our reports is reserved pending our written approval. Reports are be contacted so that field conditions can be examined and recommendations
not intended for 3rd party use. revised if necessary. The Geotechnical report states our understanding as to
the location, dimensions, and structural features proposed of the site. Any
Subsurface Exploration significant changes in the nature,design,or location of the site improvements
Subsurface exploration is normally accomplished by test borings. The soil must be communicated to F.E.T. so that the Geotechnical analysis,
boring log includes sampling information, description of the materials conclusions,and recommendations can be appropriately adjusted.
recovered,approximate depths of boundaries between soil and rock strata and
groundwater data. The log represents conditions specifically at the location
and time the boring was made. The boundaries between different soil strata Construction Observations
are indicated at specific depths;however,these depths are in fact approximate Construction observation and testing is an important element of Geotechnical
and dependent upon the frequency of sampling. The transitions between soil services. The Geotechnical Engineer's Field Representative(Field Rep.)is the
stratum are often gradual. Water level readings are made at the time the "owner's representative" observing the work of the contractor, performing
boring was performed and can change with time,precipitation,canal levels, tests,and reporting data from such tests and observations. The Geotechnical
local well drawdown,and other factors. Regardless of the thoroughness of a Engineer's Field Representative does not direct the contractor's construction
Geotechnical exploration there is always a possibility that conditions may be means,methods, operations,or personnel. The Field Rep.does not interfere
different from those of the test locations;therefore F.E.T.does not guarantee with the relationship between the owner and the contractor,and except as an
any subsoil condition surrounding the bore test holes. For a more accurate observer,does not become a substitute owner on site. The Field Rep.is only
portrayal of subsurface conditions, the site contractor should perform tests collecting data for our Engineer to review. The Field Rep. is responsible for
pits. If different conditions are encountered,F.E.T.shall be notified to review his/her safety only,but has no responsibility for the safety of other personnel
the findings and make any recommendations as needed. and/or the general public at the site. If the Field Rep.does not feel that the
site is offering a safe environment for him/her,the Field Rep.will stop his/her
observation/testing until he/she deems the site is safe. The Field Rep.is an
important member of a team whose responsibility is to observe the test and
Laboratory and Field Tests work being done and report to the client whether that work is being carried
Tests are performed in accordance with specific ASTM Standards unless out in general conformance with the plans and specifications.
otherwise indicated. All criteria included in a given ASTM Standard are not
always required and performed. Each test report indicates the measurements
and determinations actually made.
Limitations of Report
Ownership of Tests/Reports Federal Engineering&Testing,Inc.shall have no liability,in contract,tort or
All test results and/or reports prepared by FF•T.•pussuant to tMj a$re¢nqft• otherwise, for any inaccuracy, defect, or omission in interpreting this report
and/or Addendum(s) thereto, shall remain the propeq-of A.Eff.�iJI 24 and shall not in any event have any liability for lost profits or any other
monies due and owing to F.E.T. under this Xgreement and/ot A6d*dQm(,s1• indirect,special,incidental,consequential,exemplary or punitive damages.In
thereto,are paid in full. " '~ the event of future conflict between owners and contractors the following
applies: F.E.T.(s) legal and/or company representation and preparation for
Analysis and Reco�nrpe4htio4? •'• •" •'• representation fees will be billed on an hourly rate, i.e. deposition, expert
The Geotechnical report is prepared prim$rj'ly to lid ir4tl4Tl*siJ*r of site ivotk : witness, etc. F.E.T. has no obligation to amend its conclusions or
and structural foundations. Although the"f4rm4an in tai®r*4r4 is expected 0.0 recommendations after the date of this report. Any alterations or changes in
to be sufficient for these purposes,it is not intended to determine the cost of the location of the project should be brought to our attention at the earliest
construction or to stand alone as construction specifications.
convenience for review and applicability of this report.
• •• •• • • • •• ••
Phone 954-784-2941
800-848-1919
& TESTING INC. Fax 954-784-7875
250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.Com
Partial List of Services
Geotechnical Engineering Services
Soil/Aggregate Tests Field Inspection Services Asphalt Services
Soil Borings Fill&Quality Control Inspections Backscatter Density Tests
Density Compaction Tests Demucking Inspections Extractions&Gradations
Grain Size Analysis Building Inspections Marshall Limits
Moisture Contents Pile Driving Inspections Bulk Specific Gravity
Soil Classifications Pile Load Tests Cores for Thickness Determination
Limerock Bearing Ratios Steel Inspection Asphalt Pavement Monitoring
Florida Bearing Values Threshold Inspection Asphalt Assessment
Specific Gravity Bolt Inspection
Carbonate Analysis Weld Inspection Concrete Tests
Hydraulic Conductivity Vibration Monitoring Concrete Strength Testing
Organic Contents Slump Tests
L.A.Abrasion Geotechnical Engineering Windsor Probe Testing
FDOT Inspections Foundation Engineering Schmidt Hammer Testing
QC Management Foundation Design & Recommendation Core Testing
Subsoil Investigation Air Content
Earthwork Inspections Pile Load Calculations Concrete Unit Weight
QC Concrete Inspections
QC Asphalt Inspections Piling Installation Monitoring Flexual Strength Testing
Environmental Engineering Services
Phase I Site Assessments Phase 11 Site Assessments Lead Base Paint Surveys
Site Inspections Phase I Follow up on Contaminated Sites Report and Analysis
Research of Property Records Installation of Monitoring Wells Air Monitoring
Soil Borings
Soil and Ground Water Analysis
Roof Testing & Inspection Services
TAS 105 Field Fastener Withdrawal Test
TAS 106 Tile Uplift Test
TAS 124 Bell Chamber/Bonded Pull Test
TAS 126 Moisture Survey
Windload Calculation
Drainage Calculations
Lightweight Concrete placement Inspection
Roof Assessment/Evaluation
Cap Sheet Inspection
Fastener Spacing Inspection 1
Tile/Shingle/Standing Seam Inspection
Base Sheet Installation Inspectiop•• 00: ' ' 0*0 ' ' 0
Insurance Mitigation • �; .•; ; ; :.: '• AL
Retrofit Mitigation/Certification 000 • ' ' ' ' ' 0
Roof Drainage Calculations
. ... .. . .. .
•.• . •
• • MIAMFQADE
Construction Material : i. .pngcr�t>� '� Miami Dade Florida Department
Engineering Council •" ' institute County of Transportation
12C ( 2S-
2015
AUG 18 2015t h
i
C1 R
residential+retail architecture...* 0.09•0
...... .. . ......
Miami Shores Village •••••• •
Building Department ••••..
.... . .....
10050 NE 2"d Ave .,. ...... .. . ..;..•
Miami Shores, Florida 33138
tv
Re: Permit No. RC16-1257 ••••••
Proposed Renovations at: P s ••••••
1460 NE 101 ST Street
t'
Miami Shores, FI. y <<
Please see below, the written response to the comments provided during your Plan review. Please refer
to revision clouds with delta#1 on the drawings for the addressed comments.
Building
1. License contractor is required for the project.
Client will be providing Contractor information.
2. Permit application is incomplete, provide contractors information and architects information..
Client will be providing a complete application as requested.
3. This project is located in a special flood hazard area. Provide a flood legend on the plans. If the project
cost exceeds 50 percent of the market value of the building you will have to provide a survey and
elevation certificate along with providing plans to reflect compliance with the requirements of Section
R322 of the 2010 Florida Building Code-Residential.
Client will be providing Construction cost breakdown as well as updated survey
and elevations certificate Flood Elevation information is now being provided on
sheet SP-100 as per flood elevations certificate and survey.
4. Based on the information provided on the plans the work area exceeds 50 percent of the aggregate
area of the building. This project should be classified as a level 3 alteration and should comply with the
requirements of section R405 of the Florida Building Code-Existing Buildings.
Level 3 alteration is on shown in the Site Data in sheet SP-100. Due to Level of
Alteration being level 3, R-30 Insulation was added to attic and The SHGC and U
Factor for the window glazing was also coordinated with Energy Ca/cs provided.
Please refer to clouded notes on sheets A-201 for glass notes and to A-501 for Attic
Insulation notes.
T: 305.582.2836 300 Oakwood Lane Suite 100 Hollywood, FI. 33020 e: info@r-method.net
Page 1
5. Provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided
on habitable grade levels, with a door that has a 29-inch (737 mm) clear opening.
Door type#8 has been updated to be 32"wide to comply with requirement. Please
refer to door schedule on sheet A-201.
6. According to the foundation note on sheet S-0 the soil bearing capacity should be verified by a
subsurface investigation. Provide subsurface investigation and recommendations from a geo technical
engineer.
Soil test to be provided by Geotechnical Engineer. See response from Spattures
. . 0000 0000..
International attached. . .
0000.. •'•'
7. Top of footings should be a minimum of 8" below grade. •
Acknowledged, See response from Structures International attwjjed. ;••••;
9 0000..
0000 . 0000.
Feel free to contact me if you should have any questions. 90:66: *••••• ••*••'
00099009 .... 0000..
99 09
Cordially, . 0
f . . . . .0000.
0000..
. 0 .0090.
90 0 9 009
. .
Date: 08-12-15
Jose Ruben Ji enez, R.A.
AR949 3
T: 305.562.2636 300 Oakwood Lane Suite 100 Hollywood, Fl.33020 e: info@r-method.net
Page 2
STRUCTURES INTERNATIONAL, INC.
Iff
ImConsulting
Structural Engineers
0000
. . 0000 0000..
August 11,2015 ' ' •
0000..
Miami Shores Village Building Department 0000..
0000
10050 NE 2 Ave ••••••
0000 . 0000.
Miami Shores Village FL 33138 •••••• •• . 'Poe**
00 00 00 0 .000.0
:00:0:
00
. . . . 00000.
Reference: 1460 NE 101 Street "••••
. . 0000..
Miami shores FL 33138 •• ••• •
00 0
Permit Number:
Dear Building Official:
Please find below our response to comments generated on 7/30/15
COMMENTS
4. Based on the information provided on the plans the work area exceeds 50 percent of the
aggregate area of the building. This project should be classified as a level 3 alteration and
should comply with the requirements of section R405 of the Florida Building Code-Existing
Buildings.
The requirements from section R405 have been considered. See Plan Notes on sheet S-1.
6. According to the foundation note on sheet S-0 the soil bearing capacity should be verified by
a subsurface investigation. Provide subsurface investigation and recommendations from a
geo technical engineer.
Geotechnical Engineer to provide.
7501 Wiles Road,Suite 106-13,Coral Springs,FL 33067
Phone:(954)227-1512 Fax:(954)227-6633
STRUCTURES INTERNATIONAL, INC.
Consulting
Structural Engineers
7. Top of footings should be a minimum of 8"below grade. •
Top of footing has been specified. See Section 1 on sheet S-1. •••••• •• ••••••
%%I,1•V4049.P / •••••• ••i•••
1w 1 F•�q00 0 00 00:6
e �u`obmail '���� €t�iy' ••
l=Far
*Mc. .
' a ......
1V , P.E.
'MAndong$,'—q'i}al"
FL SI#2064
7501 Wiles Road,Suite 106-B,Coral Springs,FL 33067
Phone:(954)227-1512 Fax:(954)227-6633
TOB No. 15-270 LOCATION MAP HOUSE PICTURE
DATE OF SURVEY: Feb.18,2015
REVISION DATE:
CER`fIFYTO
BAY CONSTRUCTION AND DEVELOPMENT l '�
LLC
VAZQUEZ AND ASSOCIATESIs w i
! OLD REPUBLIC NATIONAL INSURANCE CO.
00
SITE ADDRESS: 1460 N.E.. 101st ST., MIAMI SHORES, FL. 33138 FOLIO No.11-3'205-024-0050
r—
>
W
N
N.W. 01st STREET 50' TOTAL
Q ------- s�2 R/W
Q - -� 20' Asphalt Pavement fl
o -
15' P/W N P.P. 6' Asphalt Pavement
O w✓M
F.I.P.
1/2*0 o 1F2 P.
(no cap) Asph C.B.S. onc. no aP)
C.B.S. Driveway Column Walk
Column TYR R=2045.40'
LL, P.O (2 x2) Plante Conc. A=100.00'5' Steps L=2'48'05"
21.8'
T 10.77' 15.0'. 1.06
17.75'
`U N (3.52.5' 0 21.65' O a 20 0' 2.0'
11 Elev.6.86 C
/--'r- Garage Porch Q
C.L.F 40.10'WJ I Q
Q in N 0.1'cl
0 1 STY. C.B.S.
v �I
E RESIDENCE water
ai O No. 1460 Pool -d YCO
-d � o F.F. Elev.9.23 F�P
u0 21.90' m
0
Y N n n -a-
CT)
a
m a o o f 35.95' co 6.0',v 11.69 0 0 l
N a0
0000p On lin 'al _ �. -� 00
.0 I p�
O LJ J m
o a
�m o 4 _ I
a w 1' C.B.S. in 124.5'•. ,P 0 0 L r1 I o i
Wall N Conc.y
and ;Pooh , 4.0'
6' Wood x 21.60' Deck - o� iv
Fence N ..e 4' C.L.F.
N I " 58.2' I
V' Lot 9, Blk 1
s' C.B.S. 0.3'al R=2165.40'
wall A=100.00'
26.0'
U
0.1'c Conc. 0 2' Conc. Seawall
00 o
1F.1-P. �� \lam Edge of V-..... �� Fnd.
(no cap) Water D/H
BISCAYNE BAY
t
LEGAL DESCRIPTION:
LOT 9,BLOCK 1,OF REPLAT OF TRACT A OF MIAMI SHORES BAY PARK ESTATES,ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT
BOOK 56 AT PAGE 86,OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY,FLORIDA.
WE HEREBY CERTIFY THAT THE ATTACHED SKETCH OF "BOUNDARY SURVEY" AND ENCROACHMENTS AND OTHER POINTS OF INTEREST:
THE SURVEY MAP RESULTING THEREFROM OF THE ABOVE DESCRIBED PROPERTY _TM ARE NO VISIBLE ENCROACHMENT OF THE SUBJECT PROPERTY
IS A TRUE AND CORRECT REPRESENTATION OF A FIELD SURVEY MADE UNDER MY
DIRECTION AND MEETS THE INTENT OF THE APPLICABLE PROVISIONS OF THE -THE SUBJECT PROPERTY IS WITHIN A FLOOD ZONE AE(SEE NOTE 1)
'MINIMUM TECHNICAL STANDARDS FOR LAND SURVEYING IN THE STATE OF -THERE IS AS'DRAINAGE EASEMENT ON THE SIDE OF THE SUBJECT
FLORIDA" PURSUANT TO RULE 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE AND PROPERTY
ITS IMPLEMENTED LAW, CHAPTER 472.027, OF THE FLORIDA STA`JTES. ,,,{{{���,,,
AMERICAN SERVICES OF MIAMI, CORP.'' ORDERED BY:
Consulting F ineers.Planners.Surveyors VAZQUEZ AND ASSOCIATES
9370 S.W.72nd STREET SUITE A-102 Ed Ptr,o GERALDO VAZQUEZ,P.A.
, PROFESSIONAk LAND,$URVEYOR AT—
MIAMI,
Tr��AT uw
MIAMI,FLORIDA 33173 AND MAPPER Nor 6771 sol Brnckell Key Dave. Bute 702
PHONE:(305)598-5101 FAX:(305)598-8627 FT It OF FwbTli6n
1 Mam, Florida 33131
LB 6683 ASOMIAMI.COM Facsimile:
Telephone: 3os-371-e°sa
Dg7E,`F€BRUARY 23. 2015 Facsimilte: 305-371-4967
. . ... . . • •..
.. .. . . . .. .. .
S�toREs . . . ... . ' '
. .
�t , 0 000
M9
E,,, ® ,.,,, iamiShprpp Village
,�„
•.: Bbig department
�NreB►�,e . •
��ORIDp' 00 10050 N.E.2nd Avenue
Miami Shoes, Florida 33138
0 00 0U . . . . . • WI: (305) 795.2204
•, Fax:(305) 756.8972
000
MIAMI SHORES VILLAGE
NOTICE TO BUILDING DEPARTMENT
OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER
THE FLORIDA BUILDING CODE
I (We)have been retained by r-method to perform special inspector services under
the Florida Building Code at the 1460 NE 101 Street project on the below listed structures as of
0624/15 (date).I am a registered architect or professional engineer licensed in the State of Florida.
PROCESS NUMBERS: 15-1257
❑ SPECIAL INSPECTOR FOR PILING,FBC 1822.1.20(R4404.6.1.20)
❑ SPECIAL INSPECTOR FOR TRUSSES>35'LONG OR 6'HIGH 2319.17.2.4.2(R4409.6.17.2.4.2)
❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY,FBC 2122.4(R4407.5.4)
SPECIAL INSPECTOR FOR STEEL CONNECTIONS,FBC 2218.2(R4408.5.2)
❑ SPECIAL INSPECTOR FOR SOIL COMPACTION,FBC 1820.3.1(R4404.4.3.1)
❑ SPECIAL INSPECTOR FOR PRECAST UNITS&ATTACHMENTS,FBC 1927.12(R4405.9.12)
❑ SPECIAL INSPECTOR FOR
Note:Only the marked boxes apply.
The following individual(s)employed by this firm or me are authorized representatives to perform inspection
1, Monzer I.Fammawi 2. Gabe Lo Fria
3. 4.
*Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or
licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional
engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an
architectural education program;successful completion of the NCEES
Fundamental Examination;or registration as building inspector or general contractor.
I, (we)will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection
services.
I, (we)understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site
for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida
Building Code,must be performed by the County.The Village building inspections must be called for on all mandatory inspections.
Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the
Department. Further,upon completion of the work under each Building Permit I will submit to the Building Inspector at the time of
final ingpectionrtheaggmpleted inspection log form and a sealed statement indicating that,to the best of my knowledge, belief and
ppm ftp portions of the project outlined above meet the intent of the Florida Building Code and are in
osllls&t ntii�Fsc �n�r `t#�e approved plans.
Si `
da d eats ��a Engineer/Architect
No. '439 a Name Monzer Faramawi
e _
n — (PST)
e � s
e Address 7501 Wlles Road,Sufte 106-8,Coral Springs,FL 33087
c STA OF =
=® % 08/24/15 •�Q`' Phone No. (954)227-1512
a� e
;v/M L
Created'drY 6k14120N `
�5RS G i• •i •�' ••• i• •i 'i'
• • • • • s • •
• ••• • •
SU;s Village
y �� ;'; :Aullding•Department
0
�ORIDA • 100 50 1i t.2nd Avenue
Miami Shores, Florida 33138
s. •• •. ...
Tel 1.(305) 795.2204
•.• S•• Fax;(305) 756.8972
MIAMI SHORES VIL1A�� •'• • • ••• ••
•
NOTICE TO BUILDING DEPARTMENT
OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER
THE FLORIDA BUILDING CODE
I (We) have been retained by OsC r G oeN M\Ve,S to perform special inspector services under
the Florida Building Code at the 1Wo® WS 10164� cgr project on the below listed structures as of
KJQqJQQ1S_ (date). I am a registered architect or professional engineer licensed in the State of Florida.
PROCESS NUMBERS:
❑ SPECIAL INSPECTOR FOR PILING,FBC 1822.1.20(R4404.6.1.20)
❑ SPECIAL INSPECTOR FOR TRUSSES>35'LONG OR 6'HIGH 2319.17.2.4.2(R4409.6.17.2.4.2)
❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY,FBC 2122.4(R4407.5.4)
❑ SPECIAL INSPECTOR FOR STEEL CONNECTIONS,FBC 2218.2(R4408.5.2)
E' SPECIAL INSPECTOR FOR SOIL COMPACTION,FBC 1820.3.1(R4404.4.3.1)
❑ SPECIAL INSPECTOR FOR PRECAST UNITS&ATTACHMENTS,FBC 1927.12(R4405.9.12)
❑ SPECIAL INSPECTOR FOR
Note:Only the marked boxes apply.
The following individual(s)employed by this firm or me are authorized representatives to perform inspection
1. �n 2.
24 Sim
3. 4f11Ig— $IgrV,a 4. SQ. _mom parr( Lr
*Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or
licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional
engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an
architectural education program;successful completion of the NCEES
Fundamental Examination;or registration as building inspector or general contractor.
I, (we)will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection
services.
I, (we) understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site
for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida
Building Code, must be performed by the County.The Village building inspections must be called for on all mandatory inspections.
Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the
Department. Further, upon completion of the work under each Building Permit I will submit to the Building Inspector at the time of
final inspection the completed inspection log form and a sealed statement indicating that,to the best of my knowledge, belief and
professional judgment those portions of the project outlined above meet the intent of the Florida Building Code and are in
substantial accordance with the approved plans.
Signed and Sealed EngineedArc itec
Namef /J 6a n C..
Address 250-W/3 c• ® d f_ —3506-7
DATE: 8 ty4s Phone No. ?Sdl 74°/
Created on 6/10/2009
1 Prope;,ty Search Application-Miami-Dade County Page 1 of 8
�nr 'HT
� .
- s
Address Owner Name Folio
SEARCH:
1460 NE 101 St. Suite D
Back to Search Results
PROPERTY INFORMATION
Folio:11-3205-024-0050
Sub-Division:
MIAMI SHORES BAY PARK ESTS AMD
Property Address
1460 NE 101 ST
Miami Shores,FL 33138-2613
Owner
BAY CONSTRUCTION AND
DEVELOPMENT LLC
Mailing Address
1460 NE 101 ST
MIAMI,FL 33138
Primary Zone
1600 SGL FAMILY-3501-4000 SQ
Primary Land Use
0101 RESIDENTIAL-SINGLE FAMILY: 1 UNIT
Beds/Baths/Half 4/3/0
Floors 1
http://www.miamidade.gov/propertysearch/ 7/11/2015
•
1• _ l t
� v+y��r�a t ��r t'•# �J��. � �3 fit' �• " �y-e r }1��� i+
s. r At
716
7 T
•r
r,
1 4
i
c
+
•
N
Property Search Application-Miami-Dade County Page 3 of 8
Comparable Sales Glossary
Non-Ad Valorem Assessments PA Additional Online Tools
Property Record Cards Property Search Help
Report Discrepancies Report Homestead Fraud
Tax Comparison Tax Estimator
TRIM Notice View Taxes
ASSESSMENT INFORMATION
Year 2015 2014 2013
Land Value $1,457,699 $617,296 $617,296
Building Value $308,070 $298,212 $300,676
Extra Feature Value $15,981 $16,114 $16,248
Market Value $1,781,750 $931,622 $934,220
Assessed Value $622,956 $618,012 $608,879
TAXABLE VALUE INFORMATION
2015 2014 2013
COUNTY
Exemption Value $50,000 $50,000 $50,000
Taxable Value $572,956 $568,012 $558,879
SCHOOL BOARD
Exemption Value
p $25,000 $25,000 $25,000
Taxable Value $597,956 $593,012 $583,879
CITY
Exemption Value
p $50,000 $50,000 $50,000
Taxable Value $572,956 $568,012 $558,879
REGIONAL
Exemption Value $50,000 $50,000 $50,000
Taxable Value $572,956 $568,012 $558,879
BENEFITS INFORMATION
Benefit Type 2015 2014 2013
Save Our Homes Cap Assessment Reduction $1,158,794 $313,610 $325,341
Homestead Exemption $25,000 $25,000 $25,000
http://www.miamidade.gov/propertysearch/ 7/11/2015
Property Search Application-Miami-Dade County Page 4 of 8
Second Homestead Exemption $25,000 $25,000 $25,000
Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Board,City,Regional).
FULL LEGAL DESCRIPTION
MIAMI SHORES BAY PK ESTS AMD
PB 56-86
LOT 9 BLK 1
LOT SIZE 102.930 X 120
OR 14213-353 0789 4
SALES INFORMATION
Previous Sale Price OR Book-Page Qualification Description Previous Owner 1
03/06/2015 $2,220,000 29528-2473 Qual by exam of deed ANGELA DE TORUNO TF
03/20/2009 $100 26822-0149 Trustees in bankruptcy,executors or guardians ANGELA TORUNO
07/01/1989 $0 00000-00000 Qual by exam of deed
04/01/1978 $192,500 10022-0943 2008 and prior year sales;Qual by exam of deed
06/01/1977 $1 09726-0268 Qual by exam of deed
03/01/1976 $165,000 00000-00000 2008 and prior year sales;Qua[by exam of deed
For more information about the Department of Revenue's Sales Qualification Codes.
2015 2014 2013
LAND INFORMATION
Land Use Muni Zone PA Zone Unit Type Units Calc Value
GENERAL R-30 1600-SGL FAMILY-3501-4000 SQ Front Ft. 102.93 $1,457,699
BUILDING INFORMATION
Building Number Sub Area Year Built Actual Sq.Ft Living Sq.Ft Adj Sq.Ft Calc Value
1 1 1954 3,611 2,435 2,934 $308,070
Building Sketches Available!
EXTRA FEATURES
Description Year Built Units Calc Value
http://www.miamidade.gov/propertysearch/ 7/11/2015
Property Search Application-Miami-Dade County Page 5 of 8
Patio-Concrete Slab 1954 671 $1,409
Pool 6'res AVG 3-8'dpth,plain feat 250-649 sf 1954 1 $10,200
Screen Enclosure-Avg Dome type 1954 1,121 $4,372
ADDITIONAL INFORMATION
*The information listed below is not derived from the Property Appraiser's Office records.It is provided for convenience and is
derived from other government agencies.
LAND USE AND RESTRICTIONS
Community Development District: NONE
Community Redevelopment Area: NONE
Empowerment Zone: NONE
Enterprise Zone: NONE
Urban Development: INSIDE URBAN DEVELOPMENT BOUNDARY
Zoning Code: R35-
Existing Land Use: 10-SINGLE-FAMILY, MED.-DENSITY(2-5 DU/GROSS ACRE).
Government Agencies and Community Services
OTHER GOVERNMENTAL JURISDICTIONS
Business Incentives
Childrens Trust
City of Miami Shores
Environmental Considerations
Florida Department Of Revenue
Florida Inland Navigation District
Miami-Dade County Bulletin Board
Non-Ad Valorem Assessments
School Board
South Florida Water Mgmt District
Tax Collector
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current
information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement
at http://www.miamidade.gov/info/disclaimer.asp
For inquiries and suggestions email us at http://www.miamidade.gov/pa/emaiYASP/f`ormNew.asp.
Version:2.0.3
http://www.miamidade.gov/propertysearch/ 7/11/2015
Property Search Application-Miami-Dade County Page 6 of 8
EXEMPTIONS 5 BENEFITS
Deployed Military
Disability Exemptions
Homestead
Institutional
Senior Citizens
More>
REAL ESTATE
40 Yr Building
Re-Certification
Appealing Your Assessment
Defective Drywall
Folio Numbers
Mortgage Fraud
More>
TANGIBLE PERSONAL PROPERTY
Appealing your Assessment
Assessment Information Search
Exemptions
Extension Requests
http://www.miamidade.gov/propertysearch/ 7/11/2015
Property Search Application- Miami-Dade County Page 7 of 8
Filing Returns
More>
PUBLIC RECORDS
Address Blocking
Change of Name
Change of Address
Change of Ownership&Title
Declaration of Condominium
More>
ONLINE TOOLS
Property Search
Property Sales
Tax Estimator
Tax Comparison
Homestead Exemption and Portability
More>
TAX ROLL ADMINISTRATION
Appealing your Assessment
Reports
http://www.miamidade.gov/propertysearch/ 7/11/2015
1 1
Ty
Uury
A REPLACEMENT COST REPORT
OF
i
A SINGLE FAMILY HOME
i
LOCATED AT
1460 NE 101-"St
Miami Shores,FL 33138
F
i1
l!
FOR
Bay Construction&Development LLC&
Miami Shores Village
BY
k
APPRAISALFIRST
REAL ESTATE APPRAISERS LLC
1444 Biscayne Boulevard, Suite 211
Miami,Florida 33132
i�
k
3
u
Appraisaff first
Real Estate Appraisers LLC
1444 Biscayne Boulevard,Suite 211
Miami Beach,Florida 33166
Phone:305-470-2100
Fax:305-381-8049
E-mail:residentlaWatoraiselfirst.net
E-mail:commercialnannraisaltirst.net
June 25,2015
Mr Goncalves
via email: ogme-alvesO1@gmail.eom
Re: A replacement cost report related to providing a letter for the depreciated building value of
a single family home located at 1460 NE 101st`St Miami Shores,FL 3 313 8.
Dear Mr. Goncalves
As requested I am writing this report to estimate the reproduction or depreciated cost,based on the
present condition of the property,for the above referenced subject building. Once again the costs
and depreciated building value are reflective of the current condition of the property.
The replacement cost new estimates will be provided via the "Marshall Valuation Service", a
nationally accepted construction cost reference guide. The cost estimate includes labor,materials,
supervision, etc. The figure also include normal site preparation, and utility lines from lot line to
building. Other soft costs such as professional fees,real estate taxes,financing fees and impact fees
are not included. The depreciation is based on the current average condition of the property. Based
on the current condition of the improvements,the physical depreciation based on the age/life metho d
is 33%.
This reproduction cost report is considered to be a restricted appraisal in accordance with Standards
Rule 2-20 of the Uniform Standards of Professional Appraisal Practice(2014-2015)and the Code
of Ethics of the Appraisal Institute and the guidelines according to(USPAP). This report is for the
sole use of the intended user.
The subject property consists of a,one-story,single family home that was built in 1954 and is of a
good construction quality. The home includes an adjusted area(as per Public Records) of 2,934
square feet.The home had been in mostly average condition on the effective date.
1460
Page Two
The home is situated on a 12,352 square foot bayfront single-family zoned lot in Miami Shores
Village.
App aiser: William K Griffith, SRA
Cert Res RD 1480
Purpose of Assignment: The purpose of the report is to provide a reproduction/depreciated
cost estimate of the subject dwelling.
Intended Use of the Report: The client intends on using this report for renovation purposes
Intexesl to be Appraised: This is a reproduction cost analysis of a home owned as a fee simple
estate.
Legal Description; MIAMI SHORES BAY PK ESTS AMD PB 56186 LOT 9 BLOCK
1,Miami-Dade County,Florida
Scope of Work: The scope of work included: inspecting the subject property;
referencing the"Marshall Valuation Service",a nationally accepted
cost manual;and estimating an appropriate depreciation rate for the
improvements.
Marshall Valuation Service:
According to the"Marshall Valuation Service"the subject improvements are classified as a Class
D-III (Masonry Veneer) High Value Residence, with an estimated economic life of 60 years. In
estimating the replacement cost new for the building,a designated cost via the"Marshall Valuation
Service"will be applied.
The depreciated building value will be based on the economic age-life method. A ratio of the
buildings effective age to its total economic life is applied to the current replacement cost new of the
improvement. This method is most effective in analyzing older buildings where the age of the long-
lived and short-lived items can not be easily estimated. According to the "Marshall Valuation
Seivice"the subject improvement have an economic life of 60 years.
However, the typical single family home in Miami Shores have far exceeded their specified
economic lives. The subject home is 60 years in age. A more practical economic life of 75 years
is estimated.
1460
Page Three
i
i
1
Marshall Valuation Service: (Continued)
Taking into account the mostly average condition of the home with limited updating, an effective
age of 25-years and a remaining economic life of 50-years(33%depreciation)will be applied..
The following is a summary of the replacement cost new and depreciated value fox the subject single
family home.
Improvement Type High Value Residence
Section&Page 12/27
Building Structure Class D(Masonry Veneer)
Type III
Direct Cost Per SF $268.95
Adjustment Multipliers
Height 1.00
Current 1.06
Local 0.98
Adjusted Direct Cost Per Square Foot $279.39
Building Size/SF 2934 sf
Replacement Cost New $819,730
Actual Age 61 years
Effective Age 25 years
Economic Life 50 years
Depreciation Rate 33%
(Eff.Age/Eco.Life)
Physical Depreciation $270,511
(Cost New x Depreciation.Rate)
Depreciated Building Cost $549,219
(Cost New-physical Depreciation)
1460
Page Four
Based on the cost manual described herein the depreciated building value of the subject property,
as of June 25,2015 is$550,000 (rounded)..
If you have any questions or need further assistance please do not hesitate to call me at(305)470-
2149.
Respectfully Submitted,
a
L�
William K Griffith, SRA
Cert Res RD 1480
billoa a p aisalfirst.net
ADDENDA
CERTIFICATION
I Certify to the best of my knowledge and belief-
The
eliefThe statements of fact contained in this report are true and correct.
The reported analyses, opinions, and conclusions are limited only by the reported
assumptions and limiting conditions are my personal, impartial,and unbiased professional
analyses,opinions, and conclusions.
I have no present or prospective interest in the property that is the subject of this report and
no personal interest with respect to the parties involved.
I have performed no services,as an appraiser or in any other capacity,regarding the property
that is the subject of this report within the three-year period immediately preceding
acceptance of this assignment.
I have no bias with respect o the property that is the subject of this report or to the parties
involved with this assignment.
My engagement in this assignment was not contingent upon developing or reporting
predetermined results.
My compensation for completing this assignment is not contingent upon the development
or reporting of a predetermined value or direction in value that favors the cause of the client,
the amount of the value opinion,the attainment of a stipulated result, or the occurrence of
a subsequent event directly related to the intended use of this appraisal.
My analyses,opinions,and conclusions were developed,and this report has been prepared,
in conformity with the Uniform Standards of Professional Appraisal Practice.
I have made a personal inspection of the property that is the subject of this report.
No one provided significant real property appraisal assistance to the person signing this
certification.
As of the date of this appraisal William K Griffith, SRA has completed the continuing
education program of the Appraisal Institute.
William K Griffith,SRA June 25, 2015
Cert Res RD 14890 Date
ASSUMPTIONS AND LIMITING CONDITIONS
The value conclusion and certification within this report are made expressly subject to the following
assumptions and limiting conditions as well as any further reservations or conditions stated within
the text of the report.
1) No responsibility is assumed for the legal description or for matters including legal or title
considerations. Title to the property is assumed to be good and marketable.
2) Responsible ownership and competent property management are assumed.
3) The information furnished by others is believed to be reliable. However, no warranty is
given for its accuracy.
4) It is assumed that there are no hidden or unapparent conditions of the property, subsoil,or
structures that render it more or less valuable. No responsibility is assumed for such
conditions or for arranging for engineering studies that may be required to discover them.
5) It is assumed that there is full compliance with all applicable federal, state, and local
environmental regulations and laws unless non-compliance,is stated,defined,and considered
in the assignment.
b) It is assumed that all required licenses, certificates of occupancy, consents, or other
legislative or administrative authority from any local,state,or national government or private
entity or organization have been or can be obtained or renewed for any use on which the
rental survey contained in this report is based.
7) It is assumed that the utilization of the land and improvements is within the boundaries of
property lines or the property described and that there is no encroachment or trespass unless
noted in this report.
8) Possession of this report, or a copy thereof, does not carry with it the right of publication.
It may not be used for any purpose by any person other than the party to whom it is addressed
without the written consent of the appraiser, and in any event only with proper written
qualification and only in its entirety.
ASSX MPTIONS AND LIMITING CONDITIONS(Continued)
9) The appraiser herein by reason of this assignment is not required to give further
consultation,testimony,or be in attendance in court with reference to the property in
question unless arrangements have been previously made.
10) Neither all nor any part of the contents of this report(especially any conclusions,the identity
of the appraiser,or any reference to the MAX or SRA designations)shall be disseminated to
the public through advertising,public relations,news,sales,or other media without the prior
written consent and approval of the appraiser.
11) The existence ofpotentially hazardous material used in the construction or maintenance of
the building and/or the existence oftoxic waste which may or may not be present on or under
the site was—not observed during our inspection. However,we are not qualified to detect
such substances. These substances, if they exist, could have a negative effect on the
estimated value of the property. The user of this report is urged to retain an expert in this
field if desired.
12) This assignment was not based on a requested minimum valuation,a specific valuation, or
the approval of a loan.
13) The client intends on using this report for tax purposes
14) The client understands, as per the engagement guidelines of this assignment,that all data
related to estimating cost and depreciation is retained in the office file.
i
I
i
i
RESUME OF QUALIFICATIONS: William K Griffith,SRA
GENERAL EDUCATION:
Florida State University B.S.Degree 1980
PROFESSIONAL EDUCATION: APPRAISAL INSTITUTE
FHA.&The Appraisal Process 2014
USPAP Update 2014
Florida Appraisal Law 2014
USPAP Update 2012
Florida Appraisal Law 2012
The Uniform Appraisal Dataset 2011
The Real Estate Market 2011 2011
Residential Design&Functional Utility 2010
Reviewing Residential Appraisals&Using FNMA 2000 2010
Roles&Rules Of Supervisory&Registered Trainee Appraisers 2010
Market Conditions Addendum/l 004MC 2009
Analyzing Distressed Real Estate 2008
Co-ops&Condos 2008
Small Hotel/Motel Valuation 2008
Business Practices&Mies 2007
New 1025-Small Residential Income Property Appraisal 2007
PROFESSIONAL AFFILIATION:
SRA,The Appraisal Institute
National Association Of Realtors,Florida Association Of Realtors
Miami Board of Realtors,Marathon/Lower Keys Board Of Realtors
BOARD EXPERIENCE:
Board Of Directors,South Florida Chapter Of The Appraisal Institute 2004-2006
LICENSES:
Cert Res RD1480(Florida),Real Estate Broker(Florida),Notary Public,Florida
REAL ESTATE AND APPRAISAL EXPERIENCE:
Partner/Owner,AppraisalFirst,LLC 2011-Present
Vice President/Residential Manager,AppraisalFirst,inc. 1987-2010
President,Biscayne RE Group. 1997-Present
President,Coast To Coast RE Group. 2009-Present
TYPES OF APPRAISAL SERVICES:
Single Family Residential 2-4 Family Dwellings FHA
REO Relocations New Construction
Vacant Land Condominiums Multi-Family/Apt.
High Value Dwellings Estates/Litigation Appraisal Review
Construction Draw Inspections Blueprint Review Cost Reports
SERVICE AREA BY FLORIDA COUNTY:
Miami-Dade,Broward,Monroe(Florida Keys),Palen Beach,St.Lucie,Martin
i
i
Property' Search Application- Miami-Dade County Page I of 2
WHCE OF THE PROPERTY APPRAMER
Summary Report
Generated On:711/2011,
Prop"Information
Follo., 11-3205-024-000
Prop"Address: 1460 NE 101 ST
Owner BAY CONSTRUCTION AND
DEVELOPMENT LLC
1460 NE 101 ST .0
Mailing Address
MIAMI,FL 33138
Primary Zone 1600 SGL FAMILY-3501-4000 SQ
Primary Land Use 0101 RESIDENTIAL-SINGLE
FAMILY:1 UNIT
Beds/Baths I Half 4/3/0
Floors 1
Living Units I
Actual Area 3,611 Sq.Ft 2014 Aerial Photography
Living Area 2,435 Sq.Ft 200ft
Adjusted Area 2,934 Scl.Ft Taxable Value Information
I Lot Size 112,351.6 Sq.Ft 1 20151 20141 2013
IYear Built 11954 County
Assessment Information Exemption Value $60,000 $50,000 $50,000
Year 2015 2014 2013 Taxable Value 1 $572,9561 $568,0121 $5515,879
Land Value $1,457,699 $617,296 $617,296 School Board
Building Value $308,070 $298,212 $300,676- Exemption Value $25,000 $26,0001 $25,000
XF Value $15,981 1 $16,114 1 $161248 Taxable Value $597,9561 $593,0121 $683,879
Market Value $1,781,750 $931,622 $934,220 city
Assessed Value $622,966 1 $618,012 $608,8 Exemption Value $50'00w] $50,0001 $50,000 1 21 Taxable Value $572,9561 $568,0121 $558,879
Benefits Information Regional
Benefit Type - 2015 2014 2013 1 Exemption Value $50,0001 $50,0001 $50,000
Save Our Homes Assessment $1,158,794 $313,610 $325,341 1 Taxable Value 1 $572,9561 $568,012 $558,879
Cap Reduction
Homestead Exemption $25,000 $25,000 $25,000 Sales Information
Second Previous OR Book-
Homestead Exemption $25,0130 $25,000 $25,000 Sale Price Page Qualification Description
Note:Not all benefits are applicable to all Taxable Values(i.e.County, 03/06/2015 $2,220,000 29528-2473 Qual by exam of dead
,School Board,City,Regional). 1 03/2012009 $100 26822-0149 Trustees In bankruptcy,executors or
guardians
Short Legal Description 0001)0-
07101/1989 $0 Qual by exam of deed
MIAMI SHORES BAY PKESTS AMD 00000
PB 56'86 12008 and prior year sales;Qua[by
LOT 9 BLK 1 04/01/1978 $192,500 10022-0943 exam of deed
LOT SIZE 102.930 X 120
OR 14213-353 0789 4
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property
Aooralser and Miami-Dade Countv assumes no llabilltv.see full disclaimer and User Aareement at htto:/Ayww.miamidado.00viinfo/disclaimer.asri
44p.://www.miamidade.gov/propertysearch/ 7/1/2015
�A%LClds..9'►C OR METHOD SNC77ONI2PAGE 27
August 2014
HIGH-VALUE RESIDENCES
CLASS TYPE EXTERIOR WALLS INTERIOR FINiSH LIGHTING AND *HEAT COST
PLUMBING Sq. M. Cu. Ft. Sq. Ft.
VI ,;�e ft sash and entries, Custom ceilings and cabinetry,inlaid Fader�sive fatales and custom
Parquet,matched atones and woods hardware throughout '.-amV $4.914.30 $57.07 $456.b5
V Best masonry,much fine trim and Coffered Flings,site-built cabs netryred whing,
,fenestration niches,many extras ' high a�inps,t o i�rrlwa HCoV OC a 4,123.37 47.88 383.07
N Fine brick,cut stone,heavy roof,best Good piaster,ornamental deta[l,marble, Good custom fixtures,more than one Complete
metal,tile,some artglaw custom carpet,parquet kitchen or food prep.area HVAC. 3,460.95 40.19 321.53
III Face brick,stone trim,slate or tile, Piaster good detail,custom catling,wall Some special custom fixtures,elecUiea[ Complete
some custom sash and tier finishes and plumbing,Integrated systems HVAC. 2,905.96 33.75 269.97
11 Brick or stone,slate or metal,heavy Plaster,some ornament,file,average Custom fixtures,electrical and
stntcturs,solarium custom carpet,hardwoods plumbing,home automation Complete 2,440.09 28.34 226.69
t Good brick,stone trim,skylights, Plaster or best drywall,Paneling,custom Some special fixtures more
shakes or metal on good structure vinyls,terrazzo,hardwoods bath per bedroom , than one H VAC e 2,049.47 23.80 190.40
VI Special site-built sash and entries, Custom callin and cabinetry,Inlaid Extensive fixtures and custom Complete
best day,slate parquet,matched stones and woods hardware throughout HVAC. 4,931.10 5726 458.11
V Best masonry veneer,much fine trim Coffered ceilings,site-built cabinetry, High-quality fixtures,structured wiring, Complete
and f masltation niches,many extras high amps,fine hardware HVAC. 4,127.46 47.93 383.45
IV Fine masonry veneer,trims,best Good plaster,ornamental detail,marble, Goad custom fixtures,more than one Complete
metal,Me,some artglass custom carpet,parquet kitchen or food preparaticrx arm HVAC. 3,456.11 40.14 321.08
MAS
EER ilii' Face brick veneer,stone trim,state or Plaster,good detail,custom ceiling,wan Some special custom futures electrical Complete
Me,some custom sash and floor finishes and plumbing,integrated systems H.VAC. 2,894.88 33.62 268M
II Brick or stone veneer,state,metal, Plaster,some ornament,file,average Custom fixtures,electrical and Complete
heavy structure,solarium custom carpet,hardwoods plumbing,home automation HVAC. 2,425.13 28.16 225.30
Doubgood le walls good
veneer,skylights, Piaster or test drywall,paneling,custom Some special fixtures,more than one Complete
rryis,terrazzo,hardwoods bath per bedroom HXAC. 2,032.03 23.60 188.78
VI Special site-built sash and entries, Custom cei0ngs and cabinetry,inlaid Extensive fixtures and custom Complete
best clay,state parquet,matched stones and woods hardware throughout H.V.A.C. 4,859.19 56.43 451.43
V Best sidings,EiPS,much tine trim and Coffered callings,ske-bunt cabinetry, Higrq�y Mures,structured wiring, Complete
fenestration niches,many extras high amps.fine hardware H.V.C. 4,066.53 4722 377.79
N Fine siding,stucco,marble trim,test Good plaster,ornamental detail,marble, Good custom fixtures,more than one Compete
Dmetal,tie,some artglass custom carpet,parquet kitchen or food preparation area HVAC. 3,404.33 39.53 316.27
iII Siding,brick or stone trim,slate or tile, Piaster,good detall,custom Comm wall Some special custom fixtures,electrical Complete
some custom sash and floor finishes and plumbing,integrated systems HVAC. 2,851.06 33.11 264.87
Ii Half timber and stone trim,slatePlaster,some ornament,tile,average Custom fixtures,electrical and Complete
,
metal,heavy structure,solarium custom carpet,hardwoods plumbing,home automation HVAC. 2,387.99 27.73 221.85
Double walls,stone trim,skylights, Plaster or test drywall,panelingcustom Some special fixtures,more than one Complete,
shakes or metal on good structure vinyls,terrazzo,hardwoods bath per bedroom H.V.A.C. 2,000.60 23.23 185.86
Fireplace,balconies and porches and built-in appliances are not included.Sea Page 35 for garage costs.The base wall height Is 10 feet(3.05 meters),excluding gables.Add or deduct 3%for each foot
(.305 meter)of deviation.For small residentiat elevators and fire sprinkler systems,see notes on Page 38 and 39.See Page 26 for basement costs.
-'HIGH-VALUE HEATING,VENTILATING AND AIR CONDITIONING COMPLETE SQUARE MEM COSTS SQUARE FOOT COSTS
H VJ6C. MILD MODERATE EXTREME mim MODERATE EXTREME
Costs for high-value mechanical items are listed separately from those for other buildings in this TYPE CUMATE cuum CLIMATE CLIMATE COMATE CUMATE
section because of the special requirements. Costs listed to the right are averages, The VI $130.05 $175.02 $235.79 $12.08 $16.26 $21.91
moderate climate cost is included in the base cost in the tables.If a cubic foot cost is used,use V 114.85 156.79 213,91 10,67 14.57 19.87
one-tenth(1110)the difference shown,to adjust the base cubic foot cost For cooling only,use N 101.49 140.38 193.85 9.43 13.04 18.01
70%to 80%of fixe costs listed.For heating only,use 60%to 70%.For ground-loop heat source u 90.22 126'44 176.84 8.41 11.74 16,43
units,add$3.86 to$5.37 per square foot $41.55 to$57.80 per square motor). I 113.64 160'`13 7'45 10.58 14.43
( p q ) 71.10 102.09 146.45 6.61 9.48 13.61
• MdRCAAU VAL11WONSERWE The data Included on ftpage becomes obsolete
02014 Con Logi A Ino.and it Uoaaars,alf r4ho reserved• Any rgwft ia&&Svtbadom aeairon ofderimwee wwft andlar �is str&e deb had scheduledforAugrrst 202(x
P�+��P�it sbictfyprohflnted 8l10I4
'y
FORM405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUIL ` u CTION
Florida Department of Business and Professional Regulation - Resid I ance ethod
Project Name: 1460 NE 101 St Builder Name:
Street: 1460 NE 101 Street Permit Office: Miami Stores
City,State,Zip: Miami Shores,FL, Permit Number.
Omer Jurisdiction: Miami Shores
Design Location: Ft,Miami
1. New c Dnstruction or existing Existing(Projecte 9. Wall Types(1849.6 sgfl) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-IM Insul,Exterior R=4.1 1849.60 ft'
b.NIA R. ft2
3. Number of units,if multiple family 1 c.NIA R. ft2
4. Number of Bedrooms 4 d.NIA R.
fie
5. Is this a worst case? No 10.Ceiling Types (2684.0 sgfL) Insulation Area
a.Under Attic(Vented) R=30.0 2684.00 ft2
6. Conditioned floor area above grade(ftq 2684 b.NIA R= ft2
Conditioned floor area below grade(ft) 0 c.NIA R= ft2
11.Ducts R ft2
7. Windows(535.8 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 536.8
a. U-Factor. Sgi,U=0.65 535.78 ft2
SHGC: SHGC=0.50
b. U-Factor: N/A ftz 12.Cooling systems kBtuhv Efficiency
SHGC: a.Central Unit 60.0 SEER:14.00
c. U-Factor: WA ft2
SHGC: 13.Heating systems kBftAv Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 31.0 COP:1.00
SHGC:
Area Weighted Average overt"Depth: 4.572 ft.
Area Weighted Average SHGC: 0. 14.Hat water systems
5
a.Electric Cap:50 gallons
8. Floor Types (2684.0 sgtt.) Insulation Area EF:0.920
a.Slab-On-Grade Edge Insulation R=0.0 2684.00 ft2 b. Conservation features
b.N/A R. ft2 None •••••
c.WA R. ft2 15kCredits • • ••••None *000 •
Glass/Floor Area: 0.200 Total Proposed Modffied Loads: 61.74 ...�.���.• .... .
Total Standard Reference Loads: 77.03 ••••• 00 •
IT'
I hereby certify that the plans and spec red by �C Review of the plans and .....• O� �A .•••
this calculation are in compliance with tl er-A' a rews�. •. fications covered by this •••• ,, s, O ..
Code, e i �•• c Cculation indicates compliance ••• >A ��� ,� . a. ,r`c�`O •
• �. 5.3gg9 0 the Florida Energy Code.
o•_ fibuicidi,=will
re oction is completed
PREPARED BY: _ _- a � � l�DATE: _- _ _--_ -- __ be inspected for • �y ypliance with Section 553.908
I hereby certify that this building,as de ,is in complia �: �Statutes.
with the Florida Energy Code. •,,r0KA.!c( p R09
�: cod W15
Otsego
OWNER/AGENT:--- - _ BUILDING OFFICIAL: -
DATE: °!..,....i�z�� DATE: .. --
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with 403.22.1.1.
- Compliance requires completion of a Florida Air Barrier and insulation Inspection Checklist
819/2015 626 PM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Title: 1460 NE 101 St Bedrooms: 4 Address Type. Street Address
Building Type: User Conditioned Area: 2684 Lot#
Owner. Total Stories: 1 BlockJSubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 1460 NE 101 Street
Permit Office: Miami Shores Cross Ventilation: County: Miami-Dade
Jurisdiction: Miami Shores Whole House Fan: City,State,Zip: Miami Shores,
Family Type: Single-family FL
New/Eidsting: Existing(Projected)
Comment:
CLIMATE
J IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer
Degree Days Moisture Range
FL,Miami FL MIAMI_INTL AP 1 51 90 70 75 149.5 --- 56- LOW
BLOCKS
Number Name Area Volume
1 Blockl 2684 21472
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infill ID Fmished Cooled Heated
1 Main 2684 21472 Yes 1 4 1 Yes Yes Yes
FLOORS
# Floor Type Space- Perimeter_ R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 145 ft 0 2684 ft2 0.5 0 0.5
ROOF 6999 "'
/ Roof Gable Roof Solar SA ••E"" Emitt••1549& Piteit• ••
V # Type Materials Area Area Color Absor. Tested **9:9* Tested Msul. •
1 Kip Barrel file 2766 ft2 0 ft2 Medium 0.75 No ••f).9• No�•••0• 14•• •
ATTIC
.. .. .. . ... ..
00
V # Type Ventilation Vent Ratio(1 in) Area RBS JRCC•• , • • •.
••••••
- —
1 Full attic Vented 300 2684 ft2 N N • ' "' ' '
CEILING
# Ceiling Type _ Space --
R_Value Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 2684 ft2 0.11 Wood
6/9/2015 6:26 PM EnergyGauge®USA-RaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
--#- -Ont To-._ wall Joe --_ Space R:Yakw R In -t-.-An- --Area R-Value F %.
-1 S Exterior Concrete Block-Int Insul Main 4.1 57 8 5 479.8 ftz 0 0.3 0
2 N Exterior Concrete Block-Int Insul Main 4.1 40 8 5 336.7 1`12 0 0.3 0
_3 W Exterior Concrete Block-Int Insul Main 4.1 45 8 5 378.8 ftp 0 0.3 0
4 E Exterior Concrete Block-Int Insul Main 4.1 35 9 8 5 300.9 tI2 0 0.3 0
5 E Exterior Concrete Block-IM Insul Main 4.1 21 8 5 176.8 IS 0 0.3 0
6 S Exterior Concrete Block-IM Insul Main 4.1 21 8 5 176.8 IF 0 0.3 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt IO Frame Panes NERC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S 6 Metal Single(Clear) Yes 0.65 0.5 106.7 W 2 It 6 in 0 ft 0 In Drapes/blinds None
2 S 1 Metal Single(Clear) Yes 0.65 0.5 193.3 W 7 ft 0 in 0 It 0 in Drapes/Winds None
3 S 1 Metal Single(Clear) Yes 0.65 0.5 53.3 ft2 7 ft0 in 0 ft 0 In Drapes/bllds None
4 N 2 Metal Single(Clear) Yes 0.65 0.5 75.8 to 2 ft 6 in 0 ft 0 in Drapes/blinds Norte
5 N 2 Metal Single(Gear) Yes 0.65 0.5 30.3 fta 2 ft 6 in 0 ft 0 in Drapes/dirtds None
6 W 3 Metal Single(Clear) Yes 0.65 0.5 18.4 IF 2 ft 6 in 0 It 0 in Drapes/blinds None
7 W 3 Metal Single(Clear) Yes 0.65 0.5 5.0 IF 2 ft6 in 0 ft 0 in Drapes/blinds None
8 W 3 Metal Single(Clear) Yes 0.65 0.5 9.8 1`12 2 ft 6 in 0 ft 0 in Drapes/blinds Norte
9 E 4 Metal Single(Clear) Yes 0.65 0.5 9.8 IF 2 ft6 in Oft 0 in
Drapes/blinds None
10 E 5 Metal Single(Clear) Yes 0.65 0.5 33.3 ftz 2 It 6 in 0 ft 0 in DrapesWinds None
GARAGE
# Floor Area Ceiling Area Exposed Wail Perimeter Avg.Wall Height Exposed Wag Insulation
1 485.98 ftz 485.98 ftx 64 ft - 8 It i 1
INFILTRATION ::0: •'•
...... .. . ... ..
# Scope Method SLA CFM 50 ELA EgLA ACH ••ACM60
1 Wholehouse Best Guess .0005 3520.1 193.25 363.43 .345g •i• •
•
HEATING SYSTEM0
.. .. .. . ... ..
# System TS ••••••
YPa_ -- -- utotype Efficiency Capacity • • • Bloct Ducts •
1 Electric Strip Heat None COP:1 31 k11r i:lb**** sys#j• ••
COOLING SYSTEM " • 009
09
.. •
# System Type Subtype _ Efficiency Capacity Au Flow SHR Block Duds
1 Central Unit Split SEER:14 60 kBk to 1800 cin 0.75 1 sys#1
8/912015 6:26 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
HOT WATER SYSTEM
# System Type SubType— Location _ EF Cap use Setpn< Conservation
Electric NoneGarage0.92 50 gal 70 gal 120 deg -- None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None fta ---
DUCTS
/ --Supply— —Retum— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool
1 Attic 6 536.8 It Attic 134.2 ft Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:None Ceiling Fans:
V=ngcooling Jan Feb Mar ]Me n Jun 11 Ju nA n Se W Oct Nov Dec
Venting Jan Feb C Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Jan Feb Mar Apr May Jun Jul Aug Sep Oct NOV Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) PM 68 68 68 6688 68 68 68 68 68 68 68 68
••.•
• 0000 0000•0
•
•• • •• •
• • . •
0000•. •• • 0000••
•
0000•• . • •
•0060•
0000 • • . •
• • •0600•
0000 • 0
0600
• •
6••0.• •• . 0000•
•• •• •••0 060000
0000•• •
•
• • • •
• • • • .0006•
0000••
• • • • •
.• • • •0• •
8/9/2015 6:26 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 05-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 1460 NE 101 Street PERMIT#:
Miami Shores, FL,
MANDATORY REQUIREMENTS SUMMARY-See Individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked,gasketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283.Windows and
doors=0.30 cfm/sq.ft.Testing or visual Inspection required. Fireplaces:
gasketed doors&outdoor combustion air.Must complete envelope
leakage report or visually verify Table 402.4.2.
Themwstat& 403.1 At least one thermostat shall be provided for each separate heating and ✓
controls cooling system.Where forced-air furnace Is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.22 All ducts,air handlers,filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers,shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 ! Heat trap required for vertical pipe risers.Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit br�alceg • ••�T' 4141...
(electric)or shutoff(gas).Circulating system pipes insulatatLV=fl-2 • • .'
+accessible manual OFF switch. •
. 4141414141
Mechanical 403.5 Homes designed to operate at positive pressure or with and t9bf kN
ventilation ventilation systems shall not exceed the minimum ASHRA VZlbyel.
No make-up air from attics,crawlspaces,garages or outdoots bbjacent'
to pools or spas. 4041:4040:
41 • • ••.•
---- - — - -- • • •
41s 4141 • • •41414141
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepowe;(1-V4f=1 ' '41
&Spas HP shall have the capability of operating at two or more spdeds. • """
Spas 4141..
and heated pools must have vapor-retardant covers or a licyid c8ver or
other means proven to reduce heat loss except if 70%of hedPfrorh
site-recovered energy.Off/timer switch required.Gas heaters minimum '
thermal efficiency=78%(820/6 after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed&attached.Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required.Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system.Electric heat>j QkW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
6/9/2015 626 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index,the more efficient the home.
1460 NE 101 Street, Miami Shores, FL,
1. New construction or existing Existing(Projecte 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1849.60 ft2
b.N/A R= ft2
3. Number of units,if multiple family 1 c.WA R= ftz
4. Number of Bedrooms 4 d.WA R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 2684.00 ft2
6. Conditioned floor area(ft2) 2684 b.N/A R= ft2
_ z
7. Windows*' Description Area 11.Ducts R R ft2
a. U-Factor: Sgl,U=0.65 535.78 ft2
SHGC: SHGC=0.50 a.Sup:Attic.Ret:Attic,AH:Garage 6 536.8
b. U-Factor: WA ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: WA ft2 a.Central Unit 60.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Strip Heat 31.0 COPA.00
Area Weighted Average Overhang Depth: 4.572 ft.
Area Weighted Average SHGC: 0.500
8. Floor Types Insulation Area 14.Hot water systems C 50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2684.00 ft2 a.Electric �'
b.WA R= ft2 EF:0.92
c.N/A R= ft2 b. Conservation features 000&
None ' '
• • 0000 0000••
15.Credits '•• s •• • None a
•••••• •• • •00400
•
000000 • • •
••••••
••a• • • • •
1 certify that this home has complied with the Florida Energy Efficiency Code for Building '•4 4•' �,� ST,�, ":"•
Construction through the above energy saving features which will be installed(or exceeded) *a *a .yo 0000
in this home before final inspection. Otherwise,a new EPL Display Card will be completed ••a•• Qi - �' 0:0
based on installed Code compliant features. 000 0 r,u, .' o •
••
Builder Signature: Date: + t, - 0
i •
Address of New Home: City/FL Zip: �.
0000 0000— CpD�.qq�
`Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
Building Input Summary Report
PROJECT
Title: 1460 NE 101 St Bedrooms: 4 Address Type: Street Address
Building Type: User Bathrooms: 0 Lot#
Owner: Conditioned Area: 2684 sq.ft. Block/SubDivision:
#of Units: 1 Total Stories: 1 PlatBook:
Builder Name: Worst Case: No Street: 1460 NE 101 Street
Permit Office: Miami Shores Rotate Angle: 0 County: Miami-Dade
Jurisdiction: Miami Shores Cross Ventilation: City,State,Zip: Miami Shores,
Family Type: Single-family Whole House Fan: FL,
New/Existing: Existing(Projected) Terrain: Suburban
Year Construct: Shielding: Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily Temp
Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 Low
UTILITY RATES
Fuel Unit Utility Name Monthly Fixed Cost $/Unit
Electricity kWh Florida Average 0 0.09
Natural Gas Therm Florida Average 0 1.72
Fuel Oil Gallon Florida Default 0 1.1
Propane Gallon Florida Default 0 1.4
SURROUNDINGS
Shade Trees Adjacent Buildings
Omt Type Height Width Distance Exist Height WicjtR"'• Distance
beef ••
N None Oft Oft Oft 0f 60 ••
: Oft • Oft •�
NE None Oft Oft Oft Of`••••• Ott••'•' Oft•••:
E None Oft Oft Oft Off,••;•• Oft • 0$
SE None Oft Oft Oft Oft 0000 0% • 0$00"
S None Oft Oft Oft 0fr0*600 01'0600 Olj••••
SW None Oft Oft Oft Oft. Oft Ofd 0
0000• •• • 0000
W None Oft Oft Oft 0ft.O•00• Of1'0"0.0 04••••
NW None Oft Oft Oft 0%***** Oft • Oft .•
BLOCKS ' ' :..•:• 6000•
Number Name Area Volume •• • • ••• •
1 Blockl 2684 21472
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
1 Main 2684 21472 Yes 1 4 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulation Main 145 ft 0 2684 11112 ____ 0.5 0 0.5
8/9/2015 6:28 PM EnergyGauge®/USRCSB v3.1 Page 1 of 5
Building Input Summary Report
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Barrel tile 2766 ft2 0 ft2 Medium 0.75 No 0.9 No 0 14
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2684 ft2 N N
CEILING
# Ceiling Type Space R-Value Area Framing Fraction Truss Type
1 Under Attic() Main 30 2684 ft2 0.11 Wood
WALLS
Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in"Project"section above.
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
# Omt o Wall Type R-Value Ft In Ft In Area R-Value Fraction Absor. Grade%
1 S Exterior Concrete Block-Int Insul Main 4.1 57 8 5 479.8 ft2 0 0.3 0
2 N Exterior Concrete Block-Int Insul Main 4.1 40 8 5 336.7 ft2 0 0.3 0
3 W Exterior Concrete Block-Int Insul Main 4.1 45 8 5 378.8 ft2 0 0.3 0
4 E Exterior Concrete Block-Int Insul Main 4.1 35 9 8 5 300.9 ft2 0 0.3 0
5 E Exterior Concrete Block-Int Insul Main 4.1 21 8 5 176.8 ft2 0 0.3 0
6 S Exterior Concrete Block-Int Insul Main 4.1 21 8 5 176.8 ft2 0 0.3 0
DOORS 0 0 0 0
•
Wi9tr• • Height •
# Omt Door Type Space Storms U-Value Ft Ino Ft• JR a Area 0 0
goes •.••••
1 Wood Main None .2 .1 .1 .1 2
goes
• •
WINDOWS .0.00
0
0000 0 00.00
0000.. •. . 00000
Wall Overhang • • • •
# Ornt ID Frame Panes NFRC U-Factor SHGC Storm Area Depth Sepa�allon*Interior Sgade Screening;
1 S 6 Metal Single(Clear) Yes 0.65 0.5 N 106.7 ft2 2 ft 6 in 0 ft Q in • prapes/plinds. Nq%e.•
2 S 1 Metal Single Clear Yes 0.65 0.5 N 193.3 ft2 7 ft 0 in 0 ft 6 in •Dr o o o
9 (Clear) � � � apes �inds None •��
3 S 1 Metal Single(Clear) Yes 0.65 0.5 N 53.3 ft2 7 ft 0 in 0 ft0 m Urapes/pftr og: Ndne •
4 N 2 Metal Single(Clear) Yes 0.65 0.5 N 75.8 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds 0 None
5 N 2 Metal Single(Clear) Yes 0.65 0.5 N 30.3 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
6 W 3 Metal Single(Clear) Yes 0.65 0.5 N 18.4 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
7 W 3 Metal Single(Clear) Yes 0.65 0.5 N 5.0 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
8 W 3 Metal Single(Clear) Yes 0.65 0.5 N 9.8 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
9 E 4 Metal Single(Clear) Yes 0.65 0.5 N 9.8 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
10 E 5 Metal Single(Clear) Yes 0.65 0.5 N 33.3 ft2 2 ft 6 in 0 ft 0 in Drapes/blinds None
8/9/2015 6:28 PM EnergyGauge®/USRCSB v3.1 Page 2 of 5
Building Input Summary Report
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s)
1 Wholehouse Best Guess .0005 3520.1 193.25 363.43 .345 9.8363 All
GARAGE
# Floor Area Roof Area Exposed Wall Perimeter _ Avg.Wall Height Exposed Wall Insulation
1 485.98 ft2 485.98 ft2 64 ft 8 ft invalid
MASS
Mass Type Area Thickness Furniture Fraction _ Space
No Added Mass 0 ft2 0 ft 0.3 Main
HEATING SYSTEM
# System Type Subtype Efficiency Capacity -----Geothermal HeatPump------- Ducts Block
Entry Power Volt. Curr
1 Electric Strip Heat None COPA 31 kBtu/hr 0 0 0 s s#1 1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Ducts Block
1 Central Unit Split SEER:14 60 kBtu/hr 1800 cfm 0.75 s s#1 1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Credits
1 Electric None Garage 0.92 50 gal 70 gal 120 deg None
SOLAR HOT WATER ••••
Collector Surface Absorp. Trans Tank Tank ••'bank• Hea!• •P V Purn p
Collector Type Tilt Azimuth Area Loss Coef. Prod. Corr. Volume U-Value a9urWea Exch%f4 Pumped .Energy
• •
DUCTS
.... . .....
DUCT ----Supply-------- -------Return-------- Air CFM 25H)(4Q6#0•
# Location R-Value Area Location Area Number Leakage Type Handler TOT .,Qyj. QN FJLF Heat CoDI'
1 Attic 6 536.8 ft2 Attic 134.2 ft2 1 Default Leaka a Garage Default)*(Defaukl ;..•;. 1 "i""
TEMPERATURES :00•'•
Programable Thermostat:None Ceiling Fans: N
CoolingJan Feb Mar Apr May Jun rX�Jul Auge Oct ( �Nov r Dec
HeatinJan Feb Mar E Apr f May f Jun [ ]Jul f Au4 Sep E Oct [X]Nov [X]Dec
VentingJan Feb Mar [X]A r [ May [ Jun [[[ ll]Jul [ Aug [ Se [X]Oct [[[XXX]]]Nov [[[ ll]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 - 78— -- 78 78 - --78 — 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
8/9/2015 6:28 PM EnergyGauge®/USRCSB v3.1 Page 3 of 5
Building Input Summary Report
APPLIANCES& LIGHTING
Appliance Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Ceiling Fans(Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33
%Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Clothes Washer AM 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872
%Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443
%Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11
%Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28
Annual Use: 2602 kWh/Yr Peak Value: 850 Watts
Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53
%Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1
%Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4
%Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 •0.8 • 0.8 0000.8 400••
%Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 •A.05 ! 0.93 •• 9.9 0.85••
Annual Use: 775 kWh/Yr Peak Value: 140 Watts 0 0.0.0 .•o... *090:4
Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 •t'1•.. 0.1 .0.1 P., ..
%Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 01)0166. 0.1 ;••0 Q 10.1
Annual Use: 0 kWh/Yr Peak Value: 0 Watts •••• • 0#000
CLOTHES WASHERS """ •' • ••.••
.. .. •. . 0000.
ID Type Screen Location Capacity Make Model";'$chedule ' LoadsPerYr '.
1 1 Main Default New Main 2.847 • ilERS20 (invalid) 0
6816 a few-
CLOTHES DRYERS • •
ID Type Screen Location Capacity Fuel Type Make Model Schedule LoadsPerYr
1 Dryers Default New Main Electricity
DISHWASHERS
ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr
1 Dishwash Default New Main 12 2004 or N HERS201 372
8/9/2015 6:28 PM EnergyGauge®/USRCSB v3.1 Page 4 of 5
Building Input Summary Report
RANGE OVEN
ID Type Screen Location Type Fueitype Make Model Cooktop Oven
1 Ranges Default New Main CooktopOven C Electric Electric FI Not Conv
MISC ELECTRICAL LOADS
ID Type Screen Item Quantity Catagory Operating Location Schedule Off Standby
1 Misc Elec Simple Default 1 1 Main HERS201 1
•
00 0
•• •• •• • ••••••
•
8/9/2015 6:28 PM EnergyGauge®/USRCSB v3.1 Page 5 of 5
0 FU.S.DEPARTMENT OF E09MLEMERGENCY OSECURITY ELEVATION CERTIFICATE
MANAGEMENT ACY OMB No. 1660-0008
National Flood Insurance Program Important: Read the instructions on pages 1-9. Expiration Date:July 31,2015
SECTION A-PROPERTY INFORMATION tNSURACOMPANY USE
Al. Building Owner's Name:BAY CONSTRUCTION DEVELOPMENT,LLC. Policy Number
A2. Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Cody NAtt~#ltimtbei ", r
1460 N.E.101STSTREET
City MIAMI SHORES State FL ZIP Code 33138
A3. Property Description(Lot and Block Numbers,Tax Parcel Number,Legal Description,etc.)
LOT 9 BLK 1 OF REPLAT OF TRACT A OF MIAMI SHORES BAY PARK ESTATES PB 56 AT PAGE 86 FOLIO 11-3205-024-0050
A4. Building Use(e.g.,Residential,Non-Residential,Addition,Accessory,etc.)RESIDENTIAL
A5. Latitude/Longitude:Lat.25°45'09" Long.-80°21'61" Horizontal Datum: ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 8
A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage:
a) Square footage of crawlspace or enclosures) 2.432 sq ft a) Square footage of attached garage 412 sq ft
b) Number of permanent flood openings in the crawispace b) Number of permanent flood openings in the attached garage
or enclosure(s)within 1.0 foot above adjacent grade 9 within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.b 1.872 sq in c) Total net area of flood openings in A9.b N/A sq in
d) Engineered flood openings? ❑ Yes ® No d) Engineered flood openings? ❑ Yes ® No
SECTION B-FLOOD INSURANCE RATE MAP(FIRM)INFORMATION
B1.NFIP Community Name&Community Number B2.County Name B3.State
VILLAGE OF MIAMI SHORES 120652 MIAMI-DADE FLORIDA
B4.Map/Panel Number B5.Suffix B6.FIRM Index Date B7.FIRM Panel B8.Flood B9.Base Flood Elevation(s)(Zone
12086CO483 L 9/11/2009 Effective/Revised Date Zone(s) AO,use base flood depth)
8/11/2009 AE 10.00
B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9.
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 139: ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑ Yes ® No
Designation Date:NIA ❑ CBRS ❑ OPA
SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations-Zones Al-A30,AE,AH,A(with BFE),VE,V1 V30,V(with BFE),AR,ARIA,ARAE,AR/A1-430,AR/AH,AR/AO.Complete Items C2.a-h
below according to the building diagram specified in Item A7.In Puerto Rico only,enter meters.
Benchmark Utilized_R& EL0L(10.02 FTI Vertical Datum: N.G.V.D.1929
Indicate elevation datum used for the elevations in items a)through h)below. ®NGVD 1929 ❑NAVD 1988 ❑Other/Source:N/A
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a)Top of bottom floor(including basement,crawlspace,or enclosure floor) 6_45 ®feet ❑meters
b)Top of the next higher floor 9.23 ®feet ❑meters
c) Bottom of the lowest horizontal structural member(V Zones only) N/A ®feet ❑meters
d)Attached garage(top of slab) 6.59 N feet ❑meters
e)Lowest elevation of machinery or equipment servicing the building 6.886 ®feet ❑meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent(finished)grade next to building(LAG) 6_6 ®feet ❑meters
g)Highest adjacent(finished)grade next to building(HAG) 6_8 ®feet ❑meters
h)Lowest adjacent grade at lowest elevation of deck or stairs,including structural support /NA ®feet ❑meters
SECTION D-SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation
information.I certify that the information on this Certificate represents my best efforts to interpret the data available.
I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code,Section 1001.
X Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a
❑ Check here if attachments. licensed land surveyor? X Yes ❑ No r , s
Certifiers Name ED PINO License Number 6771
Title PRESIDENT Company Name AMERICAN SERVICES OF MIAMI,CORP.
Address 9370 SW 7e ST.,SUITE A-102 City MIAMI State FL ZIP Code 33173
Signature Date February 24,2015 Telephone 305-598-5101
FEMA Form 086-0-33(7/12) See reverse side for continuation. Replaces all previous editions.
ELEVATION GERTIFIGATE, page Z
4 IMPORTANT;In these spaces,copy the cormsponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number
1460 N.E.101ST STREET
City MIAMI SHORES State FLORIDA ZIP Code 33138 Company NAIC Number.
SECTION D-SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION(CONTINUED)
Copy both sides of this Elevation Certificate for(1)community official,(2)insurance agent/company,and(3)building owner.
Comments HIGHTEST CROWN OF THE ROAD ELEVATION 5.72 FEET(NGVD 1929)
-SHOWN LATITUDE&LONGITUDE WERE OBTAINED WITH A HAND HELD GPS UNIT.
-SHOWN ELEV.FOR SHOWN ON C2(e)IS THE ELEV.OF THE LOWEST AIR CONDITIONER HOLDING STRUCTURE
Signature -4-- Date February 24,2015
SECTION E-BUILDING ELEVATION INFORMATION(SURVEY NOT REQUIRED)FOR ZONE AO AND ZONE A(WITHOUT BFE)
For Zones AO and A(without BFE),complete Items E1-E5.If the Certificate is intended to support a LOMA or LOMR-F request,complete Sections A,B,
and C.For Items E1-E4,use natural grade,if available.Check the measurement used.In Puerto Rico only,enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade(HAG)and the lowest adjacent grade(LAG).
a)Top of bottom floor(including basement,crawlspace,or enclosure)is ❑feet ❑meters ❑above or❑below the HAG.
b)Top of bottom floor(including basement,crawlspace,or enclosure)is ❑feet ❑meters ❑above or❑ below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 8-9 of Instructions),the next higher floor
(elevation C2.b in the diagrams)of the building is ❑feet ❑meters ❑above or ❑below the HAG.
E3. Attached garage(top of slab)is ❑feet ❑meters ❑above or ❑below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is ❑feet ❑meters ❑above or❑below the HAG.
E5. Zone AO only: If no flood depth number is available,is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? ❑Yes ❑ No ❑ Unknown.The local official must certify this information in Section G.
SECTION F-PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION
The property owner or owner's authorized representative who completes Sections A,B,and E for Zone A(without a FEMA-issued or community-issued BFE)
or Zone AO must sign here.The statements in Sections A,B,and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑Check here if attachments.
SECTION G-COMMUNITY INFORMATION(OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A,B,C(or E),and G
of this Elevation Certificate.Complete the applicable item(s)and sign below.Check the measurement used in Items G8-G10.In Puerto Rico only,enter meters.
G1.❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,engineer,or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2.❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE)or Zone AO.
G3.❑ The following information(Items G4-G10)is provided for community floodplain management purposes.
G4.Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Oocupancy Issued
G7. This permit has been issued for. ❑New Construction ❑Substantial Improvement
G8. Elevation of as-built lowest floor(including basement)of the building: ❑feet ❑meters Datum
G9. BFE or(in Zone AO)depth of flooding at the building site: ❑feet ❑meters Datum
G10.Community's design flood elevation: ❑feet ❑meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments
171 Check here if attachments.
FEMA Form 086-0-33(7/12) Replaces all previous editions.
ELEVATION CERTIFICATE, page 3 Building Photographs
See Instructions for Item A6.
IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit,Suite,and/or Bldg.No.)or P.O. Route and Box No. Policy Number:
1460 N.E. 101sT STREET
City MIAMI SHORES State FL ZIP Code 33138 Company NAIC Number:
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions
for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side
View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as
indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
FRONT VIEW(2/19/2015) SIDE VIEW 2/19/2015)
r
AI
REAR VIEW(2/19/2015)
.�'R y r_P � �•. �aTa _
119
ggM
G
Y
y s
FEMA Form 086-0-33 (7/12) Replaces all previous editions.
Miami Shores Village
��' � �i�'jlz� ,�, Building Department MAY 2 6 2 15
10050 N.E.2nd Avenue,Miami Shores, Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949
A � FSC 20 a)
BUILDING Master Permit No. 2s -7
PERMIT APPLICATION Sub Permit No.
°BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
F-1 PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: IV60 ��
City: Miami Shores �+ County Miami Dade Zip: ��I
-38
Folio/Parcel#: // 2®.7— ®���" � 0 is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): % C6f – Ze
P one#:
Address: 6�0( r
City: State: Zip:
Tenant/Lessee Name: Phone#:
0
Email: ® l 'Z a
CONTRACTOR:Company Name: .1 Phone#:
Address:
City: State,
Qualifier Name: Phone#•
State Certification or Registration#: < �eificate of Competency
DESIGNER:Architect/Engineer: 3j Phone#:
Address: City: State Zip:
Value of Work for this Permit:$ �C ��� Square/Linear Footage of Work: eqLi 3
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ /Re lace
Re air
P ' p ❑ Demolition
Description of Work: /)
Specify color of color thru tile:
Submittal Fee$ Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$
(Revised02/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved an a r ' spection fee will be charged.
Signature Signature
CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of 20Z by day of 20 by
UY4 i�e who is personally known to ,who is personally known to
me or who has produced. K4,y'Li as me or who has produced as
identificatio nd who did take an oath. identification and who did take an oath.
NOTARY BIC: NOTARY PUBLIC:
Sign.• Sign:
Print Print:
MynLAWN allilgOAL Seal:
Seal: Notary Public,State of Florida
Commission#FF 205320
My comm.expires Mar.3, 2019
************************************************************************************************************
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
Permit No. RG-5-15-'1257
Miami Shores Village Permit Type:Residential Construction
p 4� 10050 N.E.2nd Avenue NE s Work Classification:Alteration
�PerMiami Shores,FL 33138-0000 Permit Status:APPROVED
�e Phone: (305)795-2204
OR
issue oate:101512015 Expiration: 04/02/2016
Project Address Parcel Number Applicant
1460 NE 101 Street 1132050240050
BAY CONSTRUCTION $DEVEL(
Miami Shores, FL Block: Lot:
Owner Information Address Phone Cell
BAY CONSTRUCTION& 201 S BISCAYNE Boulevard (305)898-7882
-- - -- -- - - MIAMI FL 33131-
201 S BISCAYNE Boulevard
MIAMI FL 33131-
.. ... _....__. _ ._ ... _.. .... . . ._.
Contractor(s) Phone Cell Phone $ 171,295.00
Valuation:
AMENGUAL ELECTRIC INC
Total Sq Feet: 2435
Approved:In Review Available Inspections:
Comments: Inspection Type:
Date Approved::In Review Final PE Certification
Date Denied:
Window Door Attachment
Type of Construction:INTERIOR RENOVATION Occupancy:Single Family Framing
Stories: Exterior: Insulation
Front Setback: Rear Setback: Drywall Screw
Left Setback: Right Setback: Window and Door Buck
Bedrooms: Bathrooms: Fill Cells Columns
Plans Submitted:Yes Certificate Status: Review Electrical
Certificate Date: Additional Info: Review Electrical
Bond Return: Classification:Residential Review ElectricalReview Electrical
Fees Due AmountPay Date Pay Type Amt Paid Amt Due Review Building
Bond Type-Contractors Bond $500.00 Review Building
CCF Invoice# RC-5-15-55714 Review Building
$103.20 10/05/2015 Check#: 1416 $6,121.23 $360.00
COiCC Fee $50.0o Review Building
DBPR Fee $77.09 05/27/2015 Check#: 1329 $360.00 $0.00 Review Building
DCA Fee $77.09 Bond#:2861 Review Building
Education Surcharge $34.40 Review Plumbing
Miscellaneous Fee $200.00 Review Plumbing
Permit Fee $5,138.85 Review Plumbing
Plan Review Fee(Engineer) $160.00 Review Plumbing
Scanning Fee $3.00 Review Mechanical
Technology Fee $137.60 Review Mechanical
Total: $6,481.23 Review Structural
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,Pl LIMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
i
OWNERS AFFIQAVFI`-`T-c59tJV that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction a(--zoning, Futr7,_1authori z the above-named contractor to do the work stated.
October 05, 2015
Autho ' ed Signatur :Owner / Appl nt ! Contractor / Agent Date
Building Department y
October 05,2015 1