MC-16-1589
le Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-260581 Permit Number: MC-6-16-1589 Scheduled Inspection Date: August 03,2016 Permit Type: Mechanical - Residential Inspector: Perez,JanPierre Inspection Type: Final Owner: MOLINA, MICHAEL Work Classification: Addition/Alteration Job Address:952 NE 91 Terrace Miami Shores, FL Phone Number (305)672-7131 Project: <NONE> Parcel Number 1132060030130 Contractor: CHILLS AIR CONDITIONING SERVICES INC Phone: (305)778-2665 Building Department Comments DUCTWORK AND A/C REPLACEMENT. Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 02,2016 For Inspections please call: (305)762-4949 Page 5 of 29 k " 5, . Miami Shores Village � �fi � t �� M# �C � # SBtlliF 10050 N.E.2nd Avenue NE 0 Miami Shores,FL 33138-0000 Phone: (305)795-2204 . � � k;. pate:611 ' �t1h Expiration: 12/12./2016 n Project Address Parcel Number Applicant 952 NE 91 Terrace 1132060030130 Miami Shores, FL Block: Lot: MICHAEL MOLINA Owner Information Address Phone Cell MICHAEL MOLINA 952 NE 91 Terrace (305)672-7131 (786)554-6017 MIAMI SHORES FL 33138- 952 NE 91 Terrace MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 7,000.00 CHILLS AIR CONDITIONING SERVICE (305)778-2665 Total Sq Feet: 0 Tons:3 Available Inspections: Additional Info:DUCTWORK AND A/C REPLACEMENT. Inspection Type: Classification:Residential Final Approved:In Review Rough Duct Comments: Date Approved::In Review Review Electrical Date Denied: Type of Work: Review Mechanical Scanning:3 Underground Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $4.20 Invoice# MC-6-16-60111 DI3PR Fee $3.68 06/15/2016 Credit Card $222.56 $50.00 DCA Fee $3.68 Education Surcharge $1.40 06/08/2016 Credit Card $50.00 $0.00 Permit Fee $245.00 Scanning Fee $9.00 Technology Fee $5.60 Total: $272.56 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information 1 ccurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,1 authorize the above-na contractor to do the work stated. June 15, 2016 Authorized Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy June 15,2016 1 IVlldl i l l JI IUI CS V I IIdge t Building Department JU 08 2016 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 ��= INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 2W4 BUILDING Master Permit No. � a PERMIT APPLICATION Sub Permit No. [-]BUILDING ❑ ELECTRIC ❑ ROOFING REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING �IECHANICAL ❑PUBLIC WORKS [:] CHANGE OF M CANCELLATION [3S OP 19 CONTRACTOR DRAWINGS 10B ADDRESS: I S 1�i ct I 'C-t' r r' City: Miami Shores County: Miami Dade zip: 3 3 13 Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: CD OWNER:Name(Fee Simple Titleholder): ►yd� �� Phone#: 30� 763-Yl o Addresssn.� q5� !y� C, I I-tC I-eltt City: 1r1vCom% nor'[s State: EL Zip: 33130 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: l�lniA, 1C'+����� Phone#: Address: MOO .�� (� Cjsfeeft (-- 33 City. "14y►,, State: Zip: 1 Qualifier Name: 14�'l� �` .rr 1 se( nc�f`� Phone#: -�05--fy --2a�- State Certification or Registration#: C c- �����"tG( Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration [�New ❑ Repair/Replace ❑ Demolition Description of Work: �LIJC�t.�Od'1aI Specify color of color thru tile: Submittal Fee$ _ 00 Permit Fee S.a l9 CCF$ �° 2-Q) CO/CC$ Scanning Fee$ °l . (KN Radon Fee$ DBPR$ 3 G9 Notary$�0 Technology Fee$ E' roo TrainIng/Education Fee$ t . '40 Double Fee$ Structural Reviews$^ Bond$ TOTAL FEE NOW DUE 5 ��� Bonding Company's Name(if applicable) Ponding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS,HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENTCON CTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of g-J-V v'.C T 20 /G by r� day of —'I°/ 20 1�' by 'r-A4r-1140 IWO,,-who is personally known to t'�'J fcr v%-cLiekk�'who is personally known to me or who has produced Z2Z M` � -SW t'$f'I a7 as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign Sign Print: 7r& Print: Seal: No:Roth c State of Florida Seal: Co+� �Y 'I EE 208436 � �'a Notary Public State of Floridaora Exp4/2016 g Cory Roth MY COMr45ion EE 200436 �e�as�a�ee>n�aa�s+as��aa�e+aga�a�a�►�xse*�xa��x erg : >�e��s+rt��xeoe��xe�a�e�esa�*�a�ae as*�se�R°e��a�#�lr���Y+ ��iti���a.*e+�*a�t�a ae��s�e�a�aa�aa�a�x APPROVED BY Plans Examiner Zoning Structural Review Clerk e®ee MiamiShoresVillage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305)795.2204 Fax: (305) 756.8972 C CT GIT I® IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LICENCES B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. BUSINESS NAME: 01S �� �� ��� rrvJe� BUSINESS ADDRESS:__ U300 ! tw 10'� CITY is w, � _STATE ZIP �3I� BUSINESS PHONE: ( `3 ) � DAG FAX NUMBER(_) CELL PHONE ` e�—S�1 QUALIFIER'S NAME: QUALIFIER'S LIC NUMBER: �' c-to16)1- RICK SCOTT,GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD W CAC1816279 ! The CLASS B AIR CONDITIONING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 FERNANDEZ, MICHAEL ANGELO a CHILLS AIR CONDITIONING SERVICES INC 12300 SW 105 ST $ MIAMI FL 33186 ®.MIN. . ISSUED: 08/03/2014 DISPLAY AS REQUIRED BY LAW SEQ# L1408030002735 f 1 ,a►c'o CERTIFICATE OF LIABILITY INSURANCE 70TE, (MM/DD/YYYY) /22/2016 'THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsem e. PRODUCER N c JEREMY L.GARCIA INSURE LINK PHONE 954-308-1412 FA A,&A/C No: 14050 NW 14TH S7 -MAIL , JGARCIA@INSURE-LINK.COM SUITE 100 -INSURER(S)AFFORDING COVERAGE NAIL d SUNRISE FL 33323 INSURER A: PROGRESSIVE EXPRESS INSURANCE 10193 INSURED INSURER B: STARR INDEMNITYAND LIABILITY CO 38318 CHILLS AIR CONDITIONING SERVICES INC. INSURERC: 12300 SW 1057H ST INSURER D: INSURER E: MIAMI FL 33186 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTVATHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE A L BR POLY POLICY EFF POLICY EXPLTFI LIMBS GENERAL LIABILITY EACH OCCURRENCE $ 1000000 COMMERCIAL GENERAL LIABILITY PREM ISEr Ea occurrence $ 50000 CLAIMS-MADE 7 OCCUR MED EXP(An one person $ 5000 X X 1000367820161 01/23/2016 01/23/2017 PERSONAL&ADV INJURY $ 2000000 GENERAL AGGREGATE $ 2000000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 2000000 1-7 POLICY 7 PRO LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT a accident) 100,000 ANYAUTO BODILY INJURY(Per person) $ ALL AUTOS OWNED AUTOS SCHEDULED 02062371-2 02/1212016 02!12/2017 BODILY INJURY(Per accdent) $ HIREDAUTOS ANON ED PPReOPERaccid®DAMAGE $ $10,000 UM NON STACKED $ 100,000 UMBRELLALIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N TORY LIMITS ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? F7N/A E.L.EACH ACCIDENT $ (Mandatory In NFA E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attadf ACORD 101,Additional Remarks schedule,If more apace to required) Certificate holder is listed as an additional insured with regards to the general liability policy.LICENSE#CAC1816279 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Miami Shores Village BLDG Dept ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Ave AUTHORIZED REPRESENTATIVE Miami Shores FL 33138 Jeremy L.Garcia ACORD 25(2010/05) 01988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered narks of ACORD ACOO EP CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) �►� 06/08/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder Is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Pablo M Conde A&A Underwriters Inc. PHONN . (305)220-7447 A/ No): (305)220-4821 8778 SW 8st ADDRESS: pmc@aaunderwriters.com INSURER(S)AFFORDING COVERAGE NAIC# Miami FL 33174 INSURER A: BUSINESS FIRST INSURANCE COMPANY INSURED INSURER 8: CHILLS AIR CONDITIONING SERVICES,INC INSURER C: 12300 SW 105th ST. INSURER D: INSURER E Miami FL 33186 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR I TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR POLICY NUMBER M D M D COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE F-1 OCCUR DAMAGE TO RENTED PREMISES Ea occurrence $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY❑PROJECT ElLOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNEDSCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATIONX STATUTE ETH AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNERIEXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 A OFFICER/MEMBEREXCLUDED? Y N/A 830-48450 06/27/2015 06/27/2016 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 Ifyes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) License#CAC1816279 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Miami Shores Village BLDG Dept ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue AUTHORRED REPRESENTATIVE Miami Shores,FL 33138 ©1988-2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Ai s y 0.60.0 VtF •• • 0000 • � 0000•• •• 0000 • • 0000•• • • Submittal 0000 0.00• "i 06.99• • • ••66 9 ••• •••0• 000••0 00 9 • • • 90 •669 •6.99• :0000: 00 0 0 0 0 00 0 Variable Speed Convertible Air Handler 3 Ton TEM6AOC36H41 S • 0" 0 D Note:The TEM6 series air handler is designed for installation in a closet utility room,alcove,basement,crawlspace or attic.These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: ! SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires speck knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December 2014 TEM6AOC36-SUB-1-EN (MVIngerwil/Rand r � r � 0000 • 0 0000 0000.• • • • • Outline Drawing .. 0000 0000.. .. . 0000.. 066.0. • .0000. 0000 0000 . . 21.0 0 0 • • L00 It.IS 1.88 0000 0.6• 00:00• MINIMUM UNIT CLEARANCE TABLE I.DU — TO 0000•• •• • 0 0 00• 0 o COMBUSTIBLE SERVICE • . • • • MATERIAL CLEARANCE •• •• •• • •..••• IREOUIREDI (RECOMMENDED) • 0000.• • • SIDES 0• 2' • • • • FRONT 0' 21' • • • • ••..•• m1.38 BACK 0' 0' 0000.• B C INLET DUCT 0' a .•. ••000 • OUTLET DUCT 1'• N/A 0• • ••.• • • I•FDR TAE FIRST 3 FT,OF DUTLET DUCT"EK S.OJ ELECTRIC BEATERS ARE INSTALLED:0'AFTER TRE 0 0 1.59 fIRST 3 ft. 1.00 2.13 m2.00 m.ee t.11 e 5.15 O o 5.88 m 2.00 0 m 1.38 A 01 4p, I.TS e e e e H O ® e 8.T8 e T- 4.32 e 1.33 .87 18.75 1.12 7.59 1.18 2 PLt4 B,l >a L 2.15 E F D .871 PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEM6AOC36H31SA 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 All dimensions are in Inches 2 TEM6A006-SUB-1-EN T Product Specifications �• .•.. • • •••• •••• • • MODEL TEM6AOC36H31SA Volts/Ph/Hz 20$1136/1/60 ' ;00•. RATED VOLTS/PH/HZF.L.208-230/1/60 Amps 4 ••• •• •• • • •••• RATINGS(e) See O.D.Specifications FILTER •••••• • '• INDOOR COIL—Type Plate Fin Filter Furnished?(c) No •••••• Rows—F.P.I. 4-14 REFRIGERANT R�4i0A i •••♦ • ♦•i Face Area(sq.ft.) 4.59 Ref.Line Connections Brazed ♦• • Tube Size(in.) 3/8 Coupling or Conn.Size— 7/8 In.Gas Refrigerant Control TXV Coupling or Conn.Size— Drain Conn.Size((n.)(b) 3/4 NPT In.Uq. 3/8 DUCT CONNECTIONS See Outline Drawing DIMENSIONS H x W x D INDOOR FAN—Type Centrifugal Crated(In.) 52-3/4 x 27-1/2 x 25-1/2 Dlameter-Width(In.) it X 30 Uncrated 51-3/8 x 23-1/2 x 21-1/8 No.Used 1 WEIGHT Drive-No.Speeds Direct-16 Shipping(Lbs.)/Net(Lbs.) 155/144 (a) These Air Handlers are A.H.R.I certified with various Split System Air CFM vs.in.w.g. See Fan Performance Table Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance No.Motors—H.P. 1-1/2 data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) Motor Speed R.P.M. Variable M Remote filter required. TEWAOC36-SU&1-EN 3 . . .•.. ...••. Minimum Airflow CFM .... .... . . TEM6AOC36H31S • Heater Minimum Heater Alrflov4CJft• •• • o•:•• With Heat Pump •W Bout Heat PIN P, • •.•••• BAYHTR1504BRKC,BAYHTR1504LUG8 947 �••i•X96 • '• BAYHTR1505BRKC,BAYHTR1505LUGB • • • • •••••• BAYHTR1508BRKC,BAYHTR1508LUGB 947 • • 696 • :0060: BAYHTR1510BRKC,BAYHTR1510LUGB 1271 •• 625 •••• • • BAYHTR1516BRKA 1501 1150 •• • TEM6A0C36H31 Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 See following tables for heater application: Low ON ON 696 -Pressure Drop for Electrical meters Med-Lo OFF ON 825 -Minimum Heating Airflow Matrix(on unit Med-HI ON OFF 1150 nameplates) High OFF OFF 1298 4 TEM6AOC36-SUB-I-EN Heater Pressure Drop Table Number of Racks Heater Racks Airflow 1 2 1 3 1 4 Heater Model No.of Racks CFM Air Pressure Drop-Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTRI516 3 1400 0.02 0.04 0.06 0.12 1300 0.02 0.04 0.05 0.11 1200 0.01 0.04 0.05 0.10 1100 0.01 0.03 0.05 0.09 1000 0.01 0.03 0.04 0.09 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP-2 ton TEM6AOC36H31 4TWR6024H1000A 13 Degrees 4TWX60241-11000A 4A61-160241-11000A 15 SEER HP-2 ton TEM6AOB24H21 4TWR5024G1000A 14 Degrees TEM6A0B30H21 4A6H5024G1000A 15 SEER HP-3 ton TEM6A08301-121 4TWR5036G1000A 14 Degrees TEM6AOC36H31 4A6H5036G1000A TEM6AOC42H41 All other matches must be charged per the nameplate charging instructions 0000 • • 0000 00.00• •• • 0000 • 0000•• •• • 000.0• • 0000•• • • • 00.040 0000 0000 • • ••.• 0000 00.00 0000•• •• • 0000• •• •• •• • •000.0 • • • • • • • • • 00.00• • • • •6064• •• • 0000 • • • • TEM6AOC36-SUB-I-EN 5 Performance and Electrical Data Table 1. Air Flow Performance TEM6AOC36,TEM6AOC42 COOLING AIRFLOW PERFORMANCE,WET COIL,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE U(T(TONS) SETTING SETTING POWER (TONS) SWl SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW 300 CFM/ ON ON OFF ON CFM 761 755 719 654 560 ton Watts 63 98 131 163 193 2.5 NORMAL 341 CFM/ ON ON OFF OFF CFM 862 861 834 781 700 ton Watts 82 120 158 196 235 HIGH 384 CFM/ ON ON ON OFF CFM 962 963 948 915 863 ton Watts 106 147 190 234 279 LOW 319 CFM/ OFF ON OFF ON CFM 961 962 947 914 862 ton Watts 106 147 189 233 279 3 NORMAL 363 CFM/ OFF ON OFF OFF CFM 1092 1093 1082 1060 1026 ton Watts 146 192 240 288 337 HIGH 408 CFM/ OFF ON ON OFF CFM 1231 1231 1221 1203 1175 ton Watts 196 1 249 301 353 404 LOW 315 CFM/ ON OFF OFF ON CFM 1104 1105 1094 1072 1039 ton Watts 150 197 245 293 343 3.5 NORMAL 357 CFM/ ON OFF OFF OFF CFM 1258 1258 1248 1229 1201 ton I Watts 209 263 317 369 421 HIGH 402 CFM/ ON OFF ON OFF CFM 1418 1415 1401 1379 1348 ton Watts 286 347 406 462 1 516 LOW 308 CFM/ OFF OFF OFF ON CFM 1238 1238 1229 1210 1182 ton Watts 199 253 306 357 408 4 NORMAL 350 CFM/ OFF OFF OFF OFF CFM 1412 1410 1398 1378 1349 ton Watts 282 344 404 462 517 HIGH 394 CFM/ OFF OFF ON OFF CFM 1570 1528 1473 1406 1326 ton Watts 393 436 466 483 1 488 Table 2. Air Flow Performance TEMGAOC36,TEMGAOC42 HEATING AIRFLOW PERFORMANCE,NO FILTER,NO HEATER OUTDOOR SPEED AIRFLOW DIP SWITCH SETTING AIRFLOW EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SETTING POWER (TONS) SWl SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW 341 CFM/ ON ON OFF ON CFM 860 863 838 788 707 ton Watts 77 115 154 193 232 2.5 NORMAL 379 CFM/ ON ON OFF OFF CFM 949 953 937 906 852 ton Watts 98 1 138 180 224 1 269 HIGH 417 CFM/ ON ON ON OFF CFM 1042 1046 1036 1015 980 o ton Watts 122 166 212 Vjoeq 308 LOW 381 CFM/ OFF ON OFF ON CFM 1147 1144 L 7.3.141 1 1094 Lon •••• n Watts 154 203• •2 3 303 353 • 424 CFM/ CFM 1277 1279 }}272 12599 • 1228 •• 3 NORMAL ton OFF ON OFF OFF Watts 204 259 ' :314 At ' 421 ' 466 CFM/ CFM 1409 140 1 1384 1357• • • HIGH ton OFF ON ON OFF Watts 260 1 323 • 043 3 44tes 500 • • 348 CFM/ CFM 1222 1224• •P216 It"• 1174• ••• LOW ton ON OFF OFF ON Watts 180' 237•. poJ85 3#4 9 388 0,:000 3.5 NORMAL 386 CFM/ ON OFF OFF OFF CFM 1361 1363• '.&t4 $ . 1310 0009 ton Watts 240 300 ,328 L140 :8 471 • • HIGH 425 CFM/ ON OFF ON OFF CFM 1497 1472 01449 1356 • ton Watts 316 372 410 . . 494 • 338 CFM/ CFM 1360 136 • 35 13 3 336 09. 0000 LOW ton OFF OFF OFF ON Watts 239 299 • 398 4115•• 470 • • 4 NORMAL 375 CFM/ OFFOFF OFF OFF CFM 1511 1489 1456 14P2 • 1355 ton Watts 325 380 426 464 493 HIGH 413 CFM/ OFF OFF ON OFF CFM 1659 1605 1535 1450 1349 ton Watts 1 420 1 463 488 494 483 6 TEM6AOC36-SUB-I-EN Performance and Electrical Data 1. See Product Data orA/r Handler nameplate for approved combinations ofAlrHandlers and Heaters. 2. Heater model numbers may have addltionaisufflx digits. Table 3. Electrical Data TEM6AOC36,TEM6AOC42 HEATER DATA 240 Volt 208 Volt No.of Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW I BTUH Circuit Ampacity Protection No Heater 4.3* 5 15 4.3* 5 15 BAYHTR15048RKC 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 23 25 BAYHTR1504LUGB BAYHTR1505BRKC 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYHTR1505LUGB BAYHTR1508BRKC 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1508LUGB BAYHTR1510BRKC 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 BAYHTR1510LUGB BAYHBRKA Circuit itI(a) 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50 2/1 BAYHTR1516BRKA 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 F=Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps 0000 • • 0000 0000•• •• • 0000 • 0000•• •• • 0000•• • 0000•• • • • 0000•• 0000 0000 • • 0000 0000 0000• 0000•• •• • 0000• •• •• •• • 0000•• • 0000•• • • • • • • •0000• 0000•• • • • •0000• •• • 0000 • • TEM6AOC36-SUB-1-EN 7 Features and Benefits • Painted metal cabinet with captured foil face • Variable Speed ECM Motor insulation • Low Voltage Pigtail Connections • 2%or less air leakage • Draw Through Design • R-4.2 Insulating Value • Horizontal Drain Pan • Multi-Position UP/Down Flow,Horizontal Left/Right • Single Color • ALL Aluminum Coil with Enhanced Patented Coil • Fused 24V Power Fin • Electric Heaters with polarized plug connections • 1 year warranty (sold as accessory) • 10-year warranty registered • R-410AThermal Expansion Valve • Optional extended warranty available . • 41 • • r r ••rr•• •• • r•rYr• • •r••rr • • The manufacturer optimizes the performance of homes and buildings around the world.A3)usVgps of IAgersoll Ranct•••.; the leader in creating and sustaining safe, comfortable and energy efficient environments,IRe rAanufaA%Pj?ffers A • broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parrs: Fol more information,visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. @2014 Trane CH �J TEM Supersedes I-EN 05 Dec 2014 /M ersoll Rand Supersedes(New) Q s 9 Project Summa Job: 6RS07A01 W rightaofty A`i 7 Summary Date: 6/212016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Marl FL 33186,FL Phone:305-778-2665 License:CAC1816279 For: Molina 952 NE 91 Terrace, Miami Shores, FL Notes: WE'kiwi � - Weather: Miami Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 52 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 18 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13344 Btuh Structure 18287 Btuh Ducts 2118 Btuh Ducts 2349 Btuh Central vent(35 cfm) 713 Btuh Central vent(35 cfm) 612 Btuh Humidification 0 Btuh Blower 648 Btuh Piping 0 Btuh Equipment load 16176 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21897 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1754 Btuh Ducts 615 Btuh Heating Cooling Central vent(35 cfm) 1375 Btuh Area ff) 1437 1437 Equipment latent load 3744 Btuh Volume (ft3) 12907 12907 Air changes/hour 0.37 0.16 Equipment total load 25640 Btuh Equiv.AVF(cfm) 80 35 Req. total capacity at 0.79 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summag•. Make Trane Make Trane • • •0000• ..••.• Trade Electric Heat Strips Trade Split System • 0 • �• Model 7.68kw Cond 4TTR6030J1/T EI1���Q�36H3�10+*0R ....:. AHRI ref Coil 0 AHRI ref Fan Setting - HighOpmd 0.0••0 Efficiency 100 AFUE Efficiency 0.•17 SEER•oeo 0 Heating Input 7.7 kW Sensible cooling •0000.22300• WM „•„ Heating output 26200 Btuh Latent cooling 5800 ftuh • • Temperature rise 33 OF Total cooling •:2810Q:%4 '0000 Actual air flow 719 cfm Actual air flow •• •• 948Cfm ••••�• Air flow factor 0.046 cfm/Btuh Air flow factor 00•••. 0.046 dm/Btuh •• Static pressure 0.50 in H2O Static pressure ; ' ; 0.5 in x120 Space thermostat Heat/Cool Load sensible heat ratio 0 • 0.81••••• • 0 0 00.00• Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i.. 2016-Jun-02 22:46:32 Wrilgh SOlft' Right-Suite®Unhersal 2017 17.0.04 RSU01795 Page 1 AC ...rs\ADC 2015\Documents\Right J Jobs\6607a01.rup Calc=W8 Front Door faces: N t . . wrightaoft� Project Summa Job: 6112016 Summary Date: 6t4J2016 AC 2 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 • • •••• •••••• For: Molina 952 NE 91 Terrace, Miami Shores, FL '• •••' • ...... .. . ...... Notes: •••••• .... •... • . .... ..•. •.•.• ...... .. • ..•..• • . • • ••• •. . • . • ...... Weather: Miami Intl AP, FL, US Winter Design Conditions Summer Design ConditiorlJ%• Outside db 52 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 18 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 5210 Btuh Structure 7250 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(10 cfm) 197 Btuh Central vent(10 cfm) 169 Btuh Humidification 0 Btuh Blower 683 Btuh Piping 0 Btuh Equipment load 5407 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 8102 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2087 Btuh Ducts 0 Btuh Heating Cooling Central vent(10 cfm) 380 Btuh Area (ft2) 332 332 Equipment latent load 2467 Btuh Volume (ft') 2887 2887 Air changes/hour 0.84 0.37 Equipment total load 10568 Btuh Equiv.AVF(cfm) 40 18 Req. total capacity at 0.74 SHR 0.9 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Make Mitsubishi Trade Mini Spplit System Trade Mini Spplit System Model MUZ-GE12NA Cond MUZ-GE12NA AHRI ref Coil MSZ-GE12NA AHRI ref Efficiency 10 HSPF Efficiency 20.5 SEER Heating Input Sensible cooling 8880 Btuh Heating output 14400 Btuh @ 47°F Latent cooling 3120 Btuh Temperature rise 36 OF Total cooling 12000 Btuh Actual air flow 364 cfm Actual air flow 364 cfm Air flow factor 0.070 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Heat/Cool Load sensible heat ratio 0.77 Capacity balance point=0 OF Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Jun-02 22:46:32 wrilght' dft' Right-Suite®Universal 2017 17.0.04 RSU01795 Page 2 / ! ...rs\ADC 20151Documents\Right J Jobs\6r507a0l.rup Calc=MJ8 Front Door faces: N 1 - - Manual S Compliance Report Job: 6R507A01 WPightso t Date: 6/2/2016 AC 1 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 •.• •• • •••• • For: Molina 0.0.00 •• ...... 952 NE 91 Terrace, Miami Shores, FL .••.•• .... .... . . .... .... ..... ...... .. .• 0.000• • • Design Conditions ; ; ...•;• Outdoor design DB: 90.7'F Sensible gain: 21897 Btuh �•Entering coil DB: 76.24...: Outdoor design WB:77.5°F Latent gain: 3744 Btuh Entering soirft: 63.OF ' Indoor design DB: 75.0°F Total gain: 25640 Btuh Indoor RH: 50% Estimated airflow: 948 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Trane Model:4TTR6030J11TEM6AOC36H31+TDR Actual airflow: 948 cfm Sensible capacity: 22300 Btuh 102%of load Latent capacity: 5800 Btuh 155%of load Total capacity: 28100 Btuh 110%of load SHR: 79% Design Conditions Outdoor design DB: 51.7°F Heat loss: 16176 Btuh Entering coil DB: 69.1 OF Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec furnace Manufacturer: Trane Model: 7.68kw Actual airflow: 719 cfm Output capacity: 26200 Btuh 162%of load Temp. rise: 33 OF The above equipment was selected in accordance with ACCA Manual S. 2016-Jun-02 22:46:34 1:6 wrightsoft' Right-Suite®Universal 2017 17.0.04 RSU01795 Page 1 /CCk...rs\ADC 2015\Documents\Right J Jobs\660741.rup Calc=W8 Front Door faces: N Manual S Compliance Report Job: 6R507AO1 - - W t'iQ f�5®ft P Date: 6/2/2016 AC Z By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Miami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 • • • • For: Molina •••••• •• • •••••• 952 NE 91 Terrace, Miami Shores, FL 60000* • • • ••.• ••.• • • ••.• ..•. ••..• • Design Conditions :•••% ••••�• Outdoor design DB: 90.7°F Sensible gain: 8102 Btuh •ee14tring cgijp,3: 77.jF..•; Outdoor design WB:77.5°F Latent gain: 2467 Btuh Entering egijevI�: 63.6°F Indoor design DB: 75.0°F Total gain: 10568 Btuh Indoor RH: 50% Estimated airflow: 364 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Mitsubishi Model: MUZ-GE12NA+MSZ-GE12NA Actual airflow: 364 cfm Sensible capacity: 8880 Btuh 110%of load Latent capacity: 3120 Btuh 126%of load Total capacity: 12000 Btuh 114%of load SHR: 74% LEE LNEEZZEM Design Conditions Outdoor design DB: 51.7°F Heat loss: 5407 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer: Mitsubishi Model: MUZ-GE12NA+MSZ-GE12NA Actual airflow: 364 cfm Output capacity: 14400 Btuh 266%of load Capacity balance: 0 OF Supplemental heat required: 0 Btuh Economic balance: 0 OF The above equipment was selected in accordance with ACCA Manual S. 2016-Jun-02 22:46:34 = wrightsoft, Right-Suite®Universal 2017 17.0.04 RSU01795 Page 2 Ar, \...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N . . wrightsofty Comp onent Constructions Job: 612Date: 6/2/201612016 ACI By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Miami,FL 33186,FL Phone:305.778-2665 License:CAC1816279 • • •••• •••••• For: Molina • • , 952 NE 91 Terrace, Miami Shores, FL " • "••• • • Location: Indoor: j iggting •••Gdeoling•••••• Miami Intl AP, FL, US Indoor temperature (°F) 70 75 • Elevation: 30 ft Design TD (°F) :••:':8 ' 16 •, Latitude: 260N Relative humidity(%) ° SO ;,�•;� 50 •••••• Moisture difference (gr/lb: •• 2.9 • 57.1 :0#00: Outdoor: Heating Cooling (g � 1 Dr bulb °F 52 91 •• • 0900 • • Y ( ) Infiltration: Daily range (°F) - 12 ( L ) Method Simplified •••* Wet bulb (°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft' Btuhlft'--°F ft'-°F/Btuh Bk&ff Btuh BtuhV Brun Walls 13AB-Oocs:Bik wall,stucco ext,8"thk,1/2"gypsum board int fish n 203 0.258 0 4.72 958 5.69 1155 e 330 0.258 0 4.72 1558 5.69 1877 se 67 0.258 0 4.72 316 5.69 381 S 176 0.258 0 4.72 831 5.69 1001 sw 22 0.258 0 4.72 104 5.69 125 w 131 0.258 0 4.72 619 5.69 745 nw 36 0.258 0 4.72 170 5.69 205 all 965 0.258 0 4.72 4556 5.69 5490 Partitions 12A Osw:Firm wall,3/8"wood shth,1/2"gypsum board int fnsh,2"x4" 250 0.240 0 4.39 1098 4.91 1227 wood frm,24"o.c.stud 13AB-Oocs:Blk wall,stucco ext,8"thk,1/2"gypsum board int fish 74 0.258 0 4.72 349 3.52 261 16D-11td:Knee wall,tile,slate,concrete roof mat,r-11 kw ins,1/2" 53 0.081 11.0 1.48 78 2.81 148 gypsum board int fnsh Windows 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl/w brk frm mat,clr innr, n 13 0.330 0 6.04 79 7.38 96 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;6.67 ft head ht 1 E-h2fb:2 glazing,heat abs outr,air gas,mtl/w brk frm mat,clr innr, n 25 0.330 0 6.04 151 8.21 205 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45",medium; 6.67 it head ht 1 D-h2ob:2 glazing,heat abs outr,air gas,mb AN brk frm mat,clr innr, e 5 0.330 0 6.04 30 15.2 76 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;2 ft overhang(3.3 ft window ht,0.58 ft sep.);6.67 ft head ht 1 D-h2ob:2 glazing,heat abs outr,air gas,mil/w brk frm mat,cir innr, a 42 0.330 0 6.04 254 16.1 676 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;2 It overhang(4.33 ft window ht,0.58 ft sep.);6.67 ft head ht 2016-Jun-02 22:46:32 „" wrightsoft Right-Suite®Universal 2017 17.0.04 RSU01795 Page 1 eOCM...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N I D-c2om:2 glazing,clr outr,air gas,mtl no brk frm mat,clr innr,1/4" se 6 0.870 0 15.9 96 31.7 190 gap,1/8"thk;NFRC rated(SHGC=0.67);50%blinds 45°,medium;2 ft overhang(3 ft window ht,1.75 ft sep.);6.67 ft head ht 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl/w brk frm mat,clr innr, s 20 0.330 0 6.04 121 7.38 148 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;1 ft overhang(3.2 it window ht,0 ft sep.); 6.67 ft head ht 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl/w brk frm mat,clr innr, s 49 0.330 0 6.04 296 7.38 362 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;2 ft overhang(5.3 it window ht,0.5 ft sep.); 6.67 ft head ht 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl/w brk frm mat,cir innr, sw 10 0.330 0 6.04 60 9.00 90 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 50%outdoor insect screen;1.33 ft overhang(3.2 it window ht,0 ft sep.);6.67 ft head ht 1 D-c2om:2 glazing,cir outr,air gas,mtl no brk frm mat,clr innr,1/4" w 6 0.870 0 15.9 96 63.9 383 gap,1/8"thk;NFRC rated(SHGC=0.67);50%blinds 45°,medium;6.67 ft head ht 1 E-h2ftx 2 glazing,heat abs outr,air gas,mtl/w brk frm mat,cir innr, w 5 0.330 0 6.04 30 17.8 89 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; 1 ft overhang(3.2 ft window ht,0 ft sep.);6.67 ft head ht Doom 11 DO:Door,wd sc type n 20 0.390 0 7.14 143 12.1 243 n 17 0.390 0 7.14 121 12.1 207 all 37 0.390 0 7.14 264 12.1 449 11 P0:Door,mtl pur core type se 14 0.290 10.5 5.31 74 9.03 126 w 13 0.290 10.5 5.31 69 9.03 117 all 27 0.290 10.5 5.31 143 9.03 244 Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 ceil ins,1/2" 1493 0.032 30.0 0.59 874 1.11 1655 gypsum board int fish Floors 19A-Ocvhp:Fir floor,frm fir,8"thkns,hrd wd fir fnsh,leaky crwl ovr 1216 0.295 0 2.03 2466 1.74 2116 22A tpl:Bg floor,fight dry soil,on grade depth 39 0.989 0 18.1 702 0 0 0000 • • • • 0000 0000•• •• • 0000 • • • • • 0000•• •• • 000000 • 000000 • • • 0000 0000 :0000: • • • • 0000 0000 •0••• • 0000•• 000000 • • 0000• •• 00 •• • 0000•• • •••••• • • • • • • 0 00000• 0000 • • • • •00000 00 • 0000 • • • • • 0 0 2016-Jun-02 22:46:32 WrightSOft' Right-Suite@ Universal 2017 17.0.04 RSU01795 Page 2 ...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=W8 Front Door faces: N . . wrlrightsoftv Component Constructions Job: 6/2/ P Date: 6/2/20162016 AC 2 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 For: Molina 952 NE 91 Terrace, Miami Shores, FL Location: Indoor: Heating Cooling Miami Intl AP, FL, US Indoor temperature ('F) 70 75 Elevation: 30 ft Design TD (°F) 18 16 Latitude: 26°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) -12.9 57.1 Dry bulb (°F) 52 91 Infiltration: Daily range (°F) - 12 ( L ) Method Simplified Wet bulb (°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtLhV--°F ft'-°F/B" sh9w B" 13hi ft' Btuh Walls 13AB-Oocs:Blk wall,stucco ext,8"thk,1/2"gypsum board int fnsh ne 104 0.258 0 4.72 491 5.69 592 se 146 0.258 0 4.72 689 5.69 831 sw 111 0.258 0 4.72 524 5.69 631 nw 156 0.258 0 4.72 737 5.69 887 all 517 0.258 0 4.72 2441 5.69 2941 Partitions (none) Windows 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl by brk frm mat,cIr innr, se 10 0.330 0 6.04 60 ••T.97. 80 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; • • •••• 6660:9 50%outdoor insect screen;2 ft overhang(3.2 ft window ht,0.83 ft ' ' ' sep.);6.67 ft head ht • • • • 0000•• %. • 0000•• 1 D-h2ob:2 glazing,heat abs outr,air gas,mtl/w brk km mat,clr innr, se 26 0.330 0 Fye; 157 X2 X250 � 1/4"gap,1/8"thk;NFRC rated(SHGC=0.19);50%blinds 45°,medium; sw 26 0.330 0 6.24 157 9.62 Q6&••• 50%outdoor insect screen;2 ft overhang(4.2 It window ht,0.83 ft nw 26 0.330 0 0.04***. 157• Wri •381 ' sep.);6.67 ft head ht all 78 0.330 0 6V 471 "f1*3 *68:6*, ••••9. •• • 09006 Doors •• •• •• • •••9•• (none) 0.00•• • •• Ceilings 00.00. • 16D-30td:Attic ceding,tile,slate,concrete roof mat,r-30 ceil ins,1/2" 332 0.032 30.0 E.;t• • 194 1.11 4368.9• gypsum board int fish •";', ' ' •• • Floors 22A tpl:Bg floor,light dry sod,on grade depth 68 0.989 0 18.1 1231 0 0 2016-Jun-02 22:46:32 wrrghtsOft Right-Suite®Universal 2017 17.0.04 RSU01795 Page 3 ...rs\ADC 2015\Documents\Right J Jobs\6r507a01.n/p Calc=W8 Front Door faces: N -r-wri ghtsoft, Right-JO Worksheet Job: 612 AC ' Date: 6/2/2016/2016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 1 Room name AC 1 Bedroom 3 2 Exposed wall 139.8 ft 25.3 ft 3 Room height 9.0 ft d 8.4 ft heattcool 4 Room dimensions 12.8 x 12.5 ft 5 Room area 1436.9 ft' 160.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 613AB-0ocs 0.258 n 4.72 5.69 261 203 958 1155 108 95 449 540 �G 1 D-h2ob 0.330 n 6.04 7.38 13 0 79 96 13 0 79 96 L-_Gp 1E-h2fb 0.330 n 6.04 8.21 25 0 151 205 0 0 0 0 11 DO 0.390 n 7.14 12.15 20 20 143 243 0 0 0 0 11 W 13AB-0ocs 0.258 ne 0.00 0.00 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 a 4.72 5.69 377 330 1558 1877 105 84 397 478 1D-h2ob 0.330 a 6.04 15.19 5 3 30 76 0 0 0 0 1 D-h2ob 0.330 a 6.04 16.09 42 21 254 676 21 5 127 338 13AB-0ocs 0.258 se 4.72 5.69 87 67 316 381 0 0 0 0 1 D-c2om 0.870 se 15.92 31.72 6 8 96 190 0 0 0 0 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 11130 0.290 se 5.31 9.03 14 14 74 126 0 0 0 0 V,11 13AB-0ocs 0.258 s 4.72 5.69 245 176 831 1001 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 20 40 121 148 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 49 98 296 362 0 0 0 0 IW 13AB-0ocs 0.258 sw 4.72 5.69 32 22 104 125 0 0 0 0 I--ti 1 D-h2ob 0.330 sw 6.04 9.00 10 16 60 90 0 0 0 0 L__G 1 D-h2ob 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 W 13AB-0ocs 0.258 w 4.72 5.69 155 131 619 745 0 0 0 0 --G 1 D-c2om 0.870 w 15.92 63.86 6 0 96 383 0 0 0 0 1E-h2fb 0.330 w 6.04 17.75 5 3 30 89 0 0 0 0 11130 0.290 w 5.31 9.03 13 13 69 117 0 0 0 0 IW 13AB-0ocs 0.258 nw 4.72 5.69 36 36 170 205 0 0 0 0 __c 1 D-h2ob 0.330 nw 0.00 0.00 0 0 0 0 0 0 0 0 P 12A-0sw 0.240 - 4.39 4.91 267 250 1098 1227 0 0 0 0 11 DO 0.390 n 7.14 12.15 17 17 121 207 0 0 0 0 P 13AB-0ocs 0.258 4.72 3.52 74 74 349 261 0 0 0 0 P 16D-11td 0.081 - 1.48 2.81 53 53 78 148 0 0 0 0 C 16D-30td 0.032 0.59 1.11 1493 1493 874 1655 160 160 94 177 F 19A-0cvhp 0.295 2.03 1.74 1216 1216 2466 2116 160 160 324 278 F 22A-tpl 0.989 - 18.10 0.00 221 39 702 0 0 0 0 0 • • •••• • •••• •• ••• •• • •••• • s •••• • •• •••• • ••• •• ••• •• • ••••• •• •• •• • •••• 6 c)AED excursion 0 �d • • Envelope losstgain 11743 13904 • • 14%9 1868 ••0ILA • ••••• 12 a) Infiltration 1601 603 • • • 286 188 • b) Room ventilation 0 0 •• • 0 •a•••• • 13 Internal gains: Occupants @ 230 2 460 1 •••• 230 Appliances/other 3320 0 Subtotal(lines 6 to 13) 13344 18287 1755 2206 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13344 18287 1755 2206 15 Duct loads 1 16% 13% 2118 2349 16% 13% 279 283 Total room load 15463 20636 2033 2489 Air required(cfm) I 1 1 719 948 1 95 114 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr 2016-Jun-02 22:46:32 Right-Suite®Universal 2017 17.0.04 RSU01795 Page 1 ...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=W8 Front Door faces: N -r-wrightscft, Right-M Worksheet Job: 612/2016 AC 1 Date: 6/2/2016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Miami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 1 Room name Bathroom 2 Bedroom 2 2 Exposed wall 11.4 ft 19.8 ft 3 Room height 8.4 ft heat/cool 8.4 ft heat/cool 4 Room dimensions 11.4 x 12.8 ft 12.7 x 14.8 ft 5 Room area 145.9 ft' 188.0 ftz Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0ocs 0.258 n 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 n 6.04 7.38 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 n 6.04 8.21 0 0 0 0 0 0 0 0 11 DO 0.390 n 7.14 12.15 0 0 0 0 0 0 0 0 11 W 13AB-Docs 0.258 ne 0.00 0.00 0 0 0 0 0 0 0 0 1t,V 13AB-0ocs 0.258 a 4.72 5.69 96 91 430 518 107 86 406 489 I{_GG 1 D-h2ob 0.330 a 6.04 15.19 5 2 30 76 0 0 0 0 1 D-h2ob 0.330 a 6.04 16.09 0 0 0 0 21 5 127 338 13AB-0ocs 0.258 se 4.72 5.69 0 0 0 0 0 0 0 0 1 D-c2om 0.870 se 15.92 31.72 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 se 5.31 9.03 0 0 0 0 0 0 0 0 �V 13AB-0ocs 0.258 s 4.72 5.69 0 0 0 0 60 60 283 341 Imo_GG 1 D-h2ob 0.330 s 6.04 7.38 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 sw 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 sw 6.04 9.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 13-c2orn s 0.258 w 4.72 5.69 0 0 0 0 0 0 0 0 1 D�c2om 0.870 w 15.92 63.86 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 w 6.04 17.75 0 0 0 0 0 0 0 0 11 PO 0.290 w 5.31 9.03 0 0 0 0 0 0 0 0 1M 13AB-0ocs 0.258 nw 4.72 5.69 0 0 0 0 0 0 0 0 �G 1 D-h2ob 0.330 nw 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 - 4.39 4.91 0 0 0 0 0 0 0 0 1-0 11 DO 0.390 n 7.14 12.15 0 0 0 0 0 0 0 0 P 13AB-0ocs 0.258 - 4.72 3.52 0 0 0 0 0 0 0 0 P 16D-11td 0.081 - 1.48 2.81 0 0 0 0 0 0 0 0 C 1613-30td 0.032 - 0.59 1.11 146 146 85 162 188 188 110 208 F 19A-Ocvhp 0.295 - 2.03 1.74 146 146 296 254 188 188 •38,1 327 F 22A tpl 0.989 - 18.10 0.00 0 0 0 0 00 • 0 • 0 • 0 • • • ••• • •••• •• • ••• • •••••• •• • • •• ••• • • • • •• •••• • ••• •• ••• •• • 0 •so • •• •• •• • • •••- • • • • • •04 a• • • •:see• •••• • • • 6 c)AED excursion -18 20 Envelope loss/gain 841 992 1307 1724 12 a) Infiltration 129 48 224 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 2401 0 Subtotal Qines 6 to 13) 970 1280 1532 2039 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 970 1280 1532 2039 15 Duct loads 1 16% 13% 154 164 16% 13% 243 262 Total room load 1124 1445 1775 2300 Air required(cfm) 52 66 83 106 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 414- WrightSOft 2016-Jun-02 22:age 2 RightSuiteC�Universal 2017 17.0.04 RSU01795 page 2 ...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N - -wrightsoft° Right-M Worksheet Job: 6RS07A01 AC 1 Date: 6/2/2016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,NMami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 1 Room name Living Room Dining Room 2 Exposed wall 14.8 ft 0 ft 3 Room height 10.5 ft heat/cool 8.4 ft heat/cool 4 Room dimensions 1.0 x 376.0 ft 12.7 x 11.8 ft 5 Room area 376.0 ft' 149.9 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AB-0ocs 0.258 n 4.72 5.69 153 108 510 614 0 0 0 0 1 D-h2ob 0.330 n 6.04 7.38 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 n 6.04 8.21 25 0 151 205 0 0 0 0 11DO 0.390 n 7.14 12.15 20 20 143 243 0 0 0 0 11 W 13AB-Docs 0.258 ne 0.00 0.00 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 a 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 a 6.04 15.19 0 0 0 0 0 0 0 0 Tj 1 D-h2ob 0.330 a 6.04 16.09 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 se 4.72 5.69 0 0 0 0 0 0 0 0 1 D-c2om 0.870 se 15.92 31.72 0 0 0 0 0 0 0 0 1D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 11130 0.290 se 5.31 9.03 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 s 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 0 0 0 0 0 0 0 0 V�V 13AB-0ocs 0.258 sw 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 sw 6.04 9.00 0 0 0 0 0 0 0 0 1D-h2ob 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 W 13AB-0ocs 0.258 w 4.72 5.69 0 0 0 0 0 0 0 0 1 D-c2om 0.870 w 15.92 63.86 0 0 0 0 0 0 0 0 1E-h2fb 0.330 w 6.04 17.75 0 0 0 0 0 0 0 0 11 PO 0.290 w 5.31 9.03 0 0 0 0 0 0 0 0 W 13AB-0ocs 0.258 nw 4.72 5.69 0 0 0 0 0 0 0 0 _G 1 D-h2ob 0.330 nw 0.00 0.00 0 0 0 0 0 0 0 0 12A-0sw 0.240 - 4.39 4.91 210 210 922 1031 0 0 0 0 11 DO 0.390 n 7.14 12.15 0 0 0 0 0 0 0 0 P 13AB-0ocs 0.258 4.72 3.52 74 74 349 261 0 0 0 0 P 16D-11td 0.081 - 1.48 2.81 29 29 43 81 0 0 0 0 C 16D-30td 0.032 0.59 1.11 424 424 248 470 150 150 88 166 F 19A-0cvhp 0.295 2.03 1.74 376 376 763 654 150 150 •ee • 261 F 22A-tpl 0.989 18.10 0.00 0 0 0 0 :0 .0. 0 9••4 does 0 • •000 *0 •• •9• • • • •• • 0000 0• ••• • a • •9 •• •••• s •••: • 00 •090 • ••• •• ••• •• • • 0 • • • 0000• 00 of •• • •0090 • 00 •0• • • • • • •0190• • 0 •0000 00 • •000 •• •0• 6 c)AED excursion -84 -17 Envelope loss/gain 3129 3476 392 409 12 a) Infiltration 205 77 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 420 420 Subtotal Qines 6 to 13) 3334 39731 392 829 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3334 3973 392 829 r Duct loads 116% 13% 529 510 16% 13% 62 107 Total room load 3864 4483 454 936 Air required(cfm) 180 206 21 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigh�Crft 2016-Jun-02 22:age 3 Right-Suite®Universal 2017 17.0.04 RSU01795 Page 3 ...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N -+ -wrightsoft, Right-M Worksheet Job: 6RS07AOI AC 1 Date: 612/2016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 1 Room name Kitchen Family Room 2 Exposed wall 29.7 ft 38.8 ft 3 Room height 7.9 ft heat/cool 9.0 ft heaticool 4 Room dimensions 1.0 x 196.2 ft 1.0 x 221.0 ft 5 Room area 196.2 ft' 221.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (W) Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 >h13AB-0ocs 0.258 n 4.72 5.69 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 n 6.04 7.38 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 n 6.04 8.21 0 0 0 0 0 0 0 0 11 DO 0.390 n 7.14 12.15 0 0 0 0 0 0 0 0 11 W 13AB-oocs 0.258 ne 0.00 0.00 0 0 0 0 0 0 0 0 Tj13AB-Docs 0.258 a 4.72 5.69 0 0 0 0 69 69 326 393 1 D-h2ob 0.330 a 6.04 15.19 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 a 6.04 16.09 0 0 0 0 0 0 0 0 13AB-0ocs 0.258 se 4.72 5.69 0 0 0 0 87 67 316 381 1 D-c2om 0.870 se 15.92 31.72 0 0 0 0 6 4 96 190 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 11 PO 0.290 se 5.31 9.03 0 0 0 0 14 14 74 126 13AB-0ocs 0.258 s 4.72 5.69 79 59 279 336 106 57 269 324 1 D-h2ob 0.330 s 6.04 7.38 20 20 121 148 0 0 0 0 1 D-h2ob 0.330 s 6.04 7.38 0 0 0 0 49 49 296 362 13AB-0ocs 0.258 sw 4.72 5.69 32 22 104 125 0 0 0 0 1 D-h2ob 0.330 sw 6.04 9.00 10 8 60 90 0 0 0 0 1 D-h2ob 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 IW 13AB-0ocs 0.258 w 4.72 5.69 106 82 387 466 49 49 231 279 1 D-c2om 0.870 w 15.92 63.86 6 0 96 363 0 0 0 0 1 E-h2fb 0.330 w 6.04 17.75 5 1 30 89 0 0 0 0 11P0 0.290 w 5.31 9.03 13 13 69 117 0 0 0 0 V,V 13AB-0ocs 0.258 nw 4.72 5.69 0 0 0 0 36 36 170 205 t--G 1 D-h2ob 0.330 nw 0.00 0.00 0 0 0 0 0 0 0 0 P 12A-0sw 0.240 - 4.39 4.91 57 40 176 196 0 0 0 0 11130 0.390 n 7.14 12.15 17 17 121 207 0 0 0 0 P 13AB-0ocs 0.258 - 4.72 3.52 0 0 0 0 0 0 0 0 P 16D-11td 0.081 - 1.48 2.81 0 0 0 0 24 24 35 67 C 16D-30td 0.032 - 0.59 1.11 196 196 115 218 229 229 134 254 F 19A-Ocvhp 0.295 - 2.03 1.74 196 196 398 341 0 0 0 0 F 22A-tol 0.989 - 18.10 0.00 0 0 0 0 221 39 •••?O•1 0 • • •••6 • •••• • • 0000 • 0• ••• •• • 0006 • •• ••• •0 Go 0000 66 • • • 0000 • • 6 000• • •• •66• 0 • • • • • •• •• •• • 6••6•• • • • • • 0000•• 0•••• • • ••6• • • 6 c)AED excursion 200 •6 -62 Envelope loss/gain 1955 2916 2650 2519 12 a) Infiltration 291 110 466 175 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 240 Subtotal(lines 6 to 13) 2247 5026 3116 2934 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2247 5026 3116 2934 15 Duct loads 16% 13% 357 646 16% 13% 495 377 Total room load 2603 5671 3610 3311 Air required(cfm) 121 261 1 168 152 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vttr htUti#" 2016-Jun-02 22:46:32 Right-Suite®Universal 2017 17.0.04 RSU01795 Page 4 ...rs\NDC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N - -uvrightsoft° Right-J®Worksheet Job: 6R507A01 AC 2 Date: 6/2/2016 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Kami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 1 Room name AC 2 Master Suite 2 Exposed wall 68.0 ft 68.0 ft 3 Room height 8.7 ft d 8.7 ft heat/cool 4 Room dimensions 21.0 x 15.8 ft 5 Room area 331.8 ft2 331.8 ft2 Ty Construction U value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 s 0.258 n 0.00 0.00 0 0 0 0 0 0 0 0 D-h2ob 1 D-h2ob 0.330 n 0.00 0.00 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 n 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13AB-0ocs 0.258 ne 4.72 5.69 104 104 491 592 104 104 491 592 13AB-0ocs 0.258 a 0.00 0.00 0 0 0 0 0 0 0 0 � 1 D-h2ob 0.330 a 0.00 0.00 0 0 0 0 0 0 0 0 tj 1 D-h2ob 0.330 a 0.00 0.00 0 0 0 0 0 0 0 0 13AB-Oocs 0.258 se 4.72 5.69 182 146 689 831 182 146 689 831 1 D-c2om 0.870 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 se 6.04 7.97 10 18 60 BO 10 9 60 80 1 D-h2ob 0.330 se 6.04 9.62 26 37 157 250 26 18 157 250 11 PO 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0 V,11 13AB-0ocs 0.258 s 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2ob 0.330 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 s 0.00 0.00 0 0 0 0 0 0 0 0 V,11 13AB-0ocs 0.258 sw 4.72 5.69 137 111 524 631 137 111 524 631 L�_CG 1 D-h2ob 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2ob 0.330 sw 6.04 9.62 26 37 157 250 26 18 157 250 1 s 0.258 w 0.00 0.00 0 0 0 0 0 0 0 0 D-c2om 1 D-c2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 E-h2fb 0.330 w 0.00 0.00 0 0 0 0 0 0 0 0 11130 0.290 w 0.00 0.00 0 0 0 0 0 0 0 0 1dU 13AB-0ocs 0.258 nw 4.72 5.69 182 156 737 887 182 156 737 887 t-G 1 D-h2ob 0.330 nw 6.04 14.64 26 0 157 381 26 0 157 381 R 12A-0sw 0.240 - 0.00 0.00 0 0 0 0 0 0 0 0 L-p 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 P 13AB-0ocs 0.258 - 0.00 0.00 0 0 0 0 0 0 0 0 P 16D-11td 0.081 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-30td 0.032 - 0.59 1.11 332 332 194 368 332 332 194 368 F 19A-0cvhp 0.295 - 0.00 0.00 0 0 0 0 0 0 00660 0 F 22A-tpI 0.989 - 18.10 0.00 332 68 1231 0 332 68 • 1231 0 • • 0000 0000•• • • 0000 • •• ••• •• 0000•• • •• ••• • • • 0 00 0000 •0060• 6 • • • •• 0000 6•Y6• •• ••• •• • 0000• 06 •• •• • •66.60 • •• ••• • • • • • • 066.60 0000• • • • • • • • • 0.00.0 0 • 60.0 • • • • 6 c)AEDexcursion 214 00 214 Envelope losstgain 4397 4484 4397 4484 12 a) Infiltration 812 306 812 306 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 20001 2000 Subtotal pines 6 to 13) 5210 7250 5210 7250 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5210 7250 5210 7250 15 Duct loads 1 0% 0% 0 0 -0% 0%1 01 0 250 Total room load 5210 7250 5210 7 Air required(cfm) 364 364 364 364 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgh tSO t" 2016-Jun-02 22:46:32ag5 Right-SuiteO Universal 2017 17.0.04 RSU01795 Page 5 ...rs\ADC 2015\Documents\Right J Jobs\6607a01.rup Calc=W8 Front Door faces: N e .�.. wrigitsoft. Duct System Summa Job: 6R607A01 Y Date: 6/212016 AC 1 By: ADC Chills Air Conditioning Services, Inc 12300 SW 105 Street,Mami,FL 33186,FL Phone:305-778-2665 License:CAC1816279 i MEN For: Molina 952 NE 91 Terrace, Miami Shores, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.18 in H2O Available static pressure 0.32 in H2O 0.32 in H2O Supply/return available pressure 0.160/0.160 in H2O 0.160 10.160 in H2O Lowest friction rate 0.118 in/100ft 0.118 in/100ft Actual air flow 719 cfm 948 cfm Total effective length (TEL) 271 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bedroom 3 C 2489 95 114 0.118 6.0 0x0 VIFx 46.0 225.0 st3 Bathroom 2 C 1445 52 66 0.118 4.0 Ox 0 VIFx 46.0 225.0 st3 Bedroom 2 C 2300 83 106 0.118 6.0 OX 0 VIFx 46.0 225.0 st2 Living Room C 4483 180 206 0.118 8.0 Ox 0 VIFx 46.0 225.0 st2 Dining Room C 936 21 43 0.118 4.0 0x 0 VIFx 46.0 229.V*. st2 Kitchen C 5671 121 261 0.118 9.0 0X0 VIFx :$6.9'• 223V st1 Family Room h 3610 168 152 0.118 7.0 OX 0 VIFx 415'.0 ' 2$g ' st1 ' emboss ••• • Trunk Htg Clg Design Veloc Diam H x W •. •.`Duct `.•` ` •.•... Name Type (cfm) (cfm) FR (fpm) (in) (in) .• •"aterial Trunk .' st3 Peak AVF 147 181 0.118 518 8.0 0 x 0 . yinlFlx ;"' ' st2 st2 Peak AVF 430 535 0.118 501 14.0 0 x 0 •, 'V=nlFlx •.. 9• ••; st1 Peak AVF 289 413 0.118 525 12.0 0 x 0 VinlFlx ••,• ; p p Peak AVF 719 948 0.118 609 13.8 16 x 14 RectFbg Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 24x 18 719 948 0 0.118 679 16.0 Ox 0 RtFg 2016-Jun-02 22:46:34 wrfghtsoft° Right-Suite®Universal 2017 17.0.04 RSU01795 page 1 ACCk...rs\ADC 2015\Documents\Right J Jobs\6r507a01.rup Calc=MJ8 Front Door faces: N 7 W Submittal 0000 . . 0000 0000.. 0000.. 0000.. 0000 see* . . 0000 0000 0000 0000. .. . 000.0 . . . . 0 00 00 so 0 Go**:* 0000.. Split System Cooling '. . ' ' ' . . 0000.. 0000.. . . 0006.. 4TTR6O3OJ1000A _ 0.00 • Note:"Graphics in this document are for representation only.Actual model may differ in appearance.' TAG: I SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires speck knowledge and training.Improperly installed,adjusted or aftered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. October 2015 4TTR6030J-SUB-1A-EN MIIngerwil'tand I TRM/E' B II I II ilj IIII�� ISI • • •••• •••••- •• • •••• - SERVICE PANEL • • • - •••••• •• • •••••• ELECTRICAL AND REFRIGERANT ••• •• • • - COMPONENT CLEARANCES •••••• PER PREVAILING CODES. •••• •••• • - •••• •••• ••••• •••••• •• • ••••• •• •• •• • •••••• - TOP DISCHARGE AREA SHOULD BE • • • •••• - UNRESTRICTED FOR AT LEAST 1524 (5 FEET) •••••- ABOVE UNIT. UNIT SHOULD BE PLACED$O ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, ••• • •••• AND SHOULD BE AT LEAST 305 (12') FROM WALL AND •• • •••• • - ALL SURROUNDING SHRUBBERY ON TWO SIDES. • • - OTHER TWO SIDES UNRESTRICTED. •• - ELECTRICAL SERVICE PANEL K 25 (1) A 22.2 (1/8) DIA LOW VO.LTHOLEAGE 28.6 (1-I/8) DIA. K.O. WIT 22.2 (T/B) DIA. HOLE IN CONTROL BOK BOTTOM FOR ELECTRICAL POWER SUPPLY H F J K.O. FOR AL7E RNATE i1 ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, 'E' I.D. FEMALE BRAZE CONNECTION WITH I/4' SAE GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D' FLARE PRESSURE TAP FITTINGS, I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4TTR6030J 3 933 829 756 3J4 3/8 143 92 210 79 508 (36-3/4) (32-5/8) (29-3/4) (5-5/8) (3-5/8) (8-1/4) (3-1/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power(dB] Power Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 1 8000 Hz 4TTR60303 73 79 69 67 70 70 64 59 1 53 Note:Rated in accordance with AHRI Standard 270-2008 *For Reference Only 2 47TR6030J-SUB-1 A-EN TRANS° Product Specifications OUTDOOR UNIT(e)(b) 4TTR603031000A (e) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 17 M Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 25 M Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATUFF®-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the tf%Rdh circuit VOLTS/PH/HZ 208/230/1/60 selection current. • • ••••• •••••• R.L.AMPS(d)—L.R.AMPS 12.8—67.8 (e) No means no start components.I ftrr@anquick stag: starter. • components.PTC means positive temperature coef¢icie4 starter. • • FACTORY INSTALLED Optional kit shown. *so:** •• • •••••• START COMPONENTS(e) NO(Uses BAYKSKT263) M Standard Air—Dry Coil—Outdoor•�i�`•• • • • (9) This value approximate.For more ff�Tg value see(�njtQ$meplate.;•••• INSULATION/SOUND BLANKET NO (h) For standard,recommended linearlengthpndlift aaplicaffmas,see COMPRESSOR HEAT NO the Subcool Charging Chart on pagI S"r greater le?l"#and others• •+• applications,consult refrigerant piRiwgrs•fAware Pub•Ub.22-3312-xa•••• OUTDOOR FAN PROPELLER (xx denotes latest revision). • ••••• (r) Trane outdoor condensing units are factory charged wiith tie system' • DIA.(IN.)—NO.USED 23.02-1 charge required for the outdoor c:r?de:4?$unit and 15%et of tested • TYPE DRIVE—NO.SPEEDS DIRECT—1 connecting lines.If connecting line Iengthexceedse15 feet•then fine`•••s• CFM @ 0.0 IN.W.G.(0 refrigerant charge adjustment Isrecessiry.Each 1818"Ffoot over 2900 15 feet requires 0.6 lbs of refrigeaant.Seethe Installer's Guide forf4•••• NO.MOTORS—HP 1-1/8 charging instructions. •• • •00:00 • • MOTOR SPEED R.P.M. 850 as • VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.64 OUTDOOR COIL—TYPE SPINE FINm ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 21.25 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(s) 6 LBS.,7 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h)(1) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 8°F DIMENSIONS H X W X D CRATED(IN.) 42 x 30.1 x 33 WEIGHT SHIPPING(LBS.) 220 NET(LBS.) 184 4TTR6030J-SUB-1A-EN 3 TRUFF Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F.Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and Casing efficient heat transfer.The coil is protected on all four sides by louvered panels. Unit casing is constructed of heavy gauge,galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The As manufactured,this system has a cooling capacity to corner panels are prepainted.All panels are subjected 55°F.The addition of an evaporator defrost control to our 1,000 hour salt spray test.The base is made of a permits operation to 40'F The addition of an CMBF G30 weatherproof material to resist corrosion. evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling(manual and automatic change over).Sub-base to match compressor contactor and high pressure switch.High thermostat and locking thermostat cover. •�•• and low pressure controls are inherent to the 0 compressor.Afactory supplied liquid line drier is Evaporator Defrost Control,—See Low An, ont. ••••0• ' standard.Some models may require field installation. Cooling. •• • •••• • 000.60 0. 9 9096.6 969096 0 :0000: . 0 6.9.9 9006 0060 . • . . . 9.96 0000 0000. 90096. .. . 9.699 . 6 . .. .. 69 . ...6.. 69..99 . 9000.. . 00.0.0 0 0 . . 9 09009 .• . 0000 . . 6 6 .N CERTIFIED.- cqT)- us Intertek MAKE Trane optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand,the leader in creating and sustaining safe,comfortable and energy efficient environments,Trane offers a broad portfolio of advanced controls and HVAC systems,comprehensive building services,and parts.For more information,visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2015 Trane 47rR8030J-SUB-1A-EN 01 Oct 2015 CIR/Ingersoll Rand Supersedes(New) • y� Job Name: System Reference: Date: ENERGY STAR@.....................................Yes ENERGY STAR products are third-parry certified by an EPA-recognized Certification Body. Electrical Requirements f Power Supply.................... 208/230V,1-Phase,60 Hz Breaker Size........................................15 A Indoor Unit MSZ-GE12NA-8 Voltage Indoor-Outdoor S1-S2 ......................AC 208/230V Indoor-Outdoor S2-S3 ...........................DC ±24Vwireless Remote ,. � �x Indoor-Remote Controller..................... MHK1 DC 3V Controller Outdoor Unit MUZ-GE12NA PAR-31 MAA DC 12V PAC-YT53CRAU DC 12V OPERATING RANGE Indoor Intake Air Outdoor Intake Temp. Air Temp. GENERAL FEATURES Maximum 90o F(32°C)DB 115°F(46°C)DB • Wall-mounted indoor unit 73 F 23 C WB • Standard Hybrid Catechin Prefilter is included with indoor unit Cooling' 67°F(19-C)DB • Quiet operation Minimum 57°F 14°CWB 14°F(-10°C)DB • Auto fan speed control:Quiet,Low,Medium,High,and Super High 80°F(27°C)DB 75°F(24°C)DB • Hand-held Wireless Remote Controller Maximum 67°F 19°C WB 65°F 18°C WB • Indoor unit powered from outdoor unit using A-Control Heating 70°F(21°C)DB -4°F(-20°C)DB5 • Auto restart following a power outage Minimum • Anti-allergy Enzyme Filter 60°F 16°C WB -5°F(-210 C WB Limited warranty: ears arts and seven ears compressor °Applications should be restricted to comfort cooling only;equipment cooling applications are not tY Y P Y P recommended for low ambient temperature conditions. 'System cuts out at-9"F(-27°C)to avoid thermistor error and automatically restarts at-0•F(-20°C). ACCESSORIES •����• Indoor Unit Indoor Unit ❑ Condensate Pump(BlueDiamond X87-711/721;115/230V) MCA........................4•...t..... !i!. 1A • ❑ Condensate Pump(Sauermann S130-115/230;115/230V) Blower Motor(ECM)........... 0;56 F.L.q••••• ❑ Anti-Allergy Enzyme Filter(MAC-408FT E) Airflow(Quiet-Lo-Med-Hi-Super H' ❑ Drain Pan Level Sensor(DPLS2) Cooling 146 v -237-321-399 Dry CFO..••; 109,•'I. a 201-286.864 Wet CFM • Outdoor Unit Heating ................ 1421-J%%-12 37-321.04.Qpbry CFV00.• ❑ Thr0gole Disconnect Switch(TAZ-MS303) • • El I.Outlet Guide(MAC-889SG) Sound Pressure Level(Quiet-Lo-Me&-0141-Sup • ••••• 11 Mounting Base(DSD-400N) Cooling ...................0 0'.&19-22- r") 45 dBO4••••• ❑ Mounting Pad(ULTRILITEI) Heating ........................19-22-30-37-43 dB(A) • c3 Wall Mounting Bracket(QSWB2000M-1) i i i • DIMENSIONS PNIT I CHES M••• 0 0•• Controller Options W 'I� 799 •••• ❑ Wireless Controller(MHK1) D /232 ••••❑ Wired Remote Controller PAR-31 MAA(Requires MAC-3331F-E) H /295 •• • ❑ Wireless Interface for kumo cloud (PAC-WHS01 WF-E) ❑ Thermostat Interface(PAC-US444CN-1) Weight.....................................22 lbs./10 kg External Finish.....................Munsell No.1.0Y 9.2/0.2 SPECIFICATIONS Field Drainpipe Size O.D......................5/8"/15.88 mm Cooling' Rated Capacity...............................12,000 Bluth Outdoor Unit Minimum Capacity.............................3,800 Btu/h Compressor.............................DC Inverter-driven SEER. ...................................20.5 Btu/h/W MCA ... 12A Total Input........................................960 W Fan Motor(ECM) 0.50 F.L.A. ............................... Heating at 47°F2 Sound Pressure Level Rated Capacity...............................14,400 Bluth Cooling ......................................49 dB(A Minimum Capacity .............................5,500 Btu/h Heating ......................................51 dB(A; HSPF ..................................... 10.0 Btu/h/W Total Input...................................... 1,170 W DIMENSIONS INCHES/MM Heating at 17°F3 W 31-1/21800 Rated Capacity................................8,800 Btu/h Rated Total Input ..................................900 W D 11-1/4/286 Maximum Capacity" ..........................11,200 Btu/h H 21-5/8/549 Maximum Total Input ............................. 1,200 W 'Cooling Indoor.80°F(27°C)DB/67°F(19°C)WB' Weight ........................... 77 lbs./35 kg 'Cooling Outdoor.95°F(35°C)DB/75°F(24°C)WB' External Finish......................Munsell No.3Y 7.8/1.1 2 Heating at 47°F Indoor 70°F(21°C)DB/60°F(16°C)WB' Refrigerant Type...................................R410A 2 Heating at 47°F Outdoor.47°F(8°C)DB/43°F(6°C)WB' Refrigerant Pipe Size O.D. 3 Heating at 17°F Indoor.70°F(21°C)DB/600 F(16°C)WB' Gas Side.................................3/8"/9.52 mm 3 Healing at 17°F Outdoor.17°F(8°C)DB/15°F(9°C)WB' Liquid Side................................1/4"/6.35 mm `Rating Conditions per AHRI Standard Max.Refrigerant Pipe Length.....................65 ft.120 m "Maximum Capacity is at full speed and performance for Max.Refrigerant Pipe Height Difference ............40 ft.112 m INVERTER-driven System. Connection Method ................................ Flared Specifications are subject to change without notice. O 2016 Mitsubishi Electric US,Inc. 57- ;$. as• i ® ® a la 4 d MSZ-GE12NA-8 Unit:Inch 7118.1 Obl note 7116x13/18 Oblona hole 3.1 7/8 8.7 1 Installation late 30-1/16 114 t0 8.118 8.118 2 13.8118 1 9116 2-1/8 311_6 9.1/8 Indoor unit Air In Wall hole 02.9/16 n �J Installation Dlate I 16d A N N m CS )A 1-15118 74.= 8.18 1 N Drain hose 2.61 8 T Air out 4- m Irreuletlon mi-are 0.1) Uquld Aire m1/419-11/16(Flared connection 0/4) &3178 1.15/18 Oae line m3/818m3180E08Po9112NA,mi@OE1fH8dA)) Drain hose insulation o1-118 O.D Conneded part m9/8 O.D 0000 • 9 MUZ-GE12NA • • • •• • 0000 • ••Oit!Inch •• • 0000•• 15-3/4 v Drain hole 01-5/8 • •••• • • • b Air in REQUIRED SPACE Basically open*4 Toch or more •••••• without any obstracgdhtn front •••• • • v and on both SAW W&H, e••••• ••••• ••• •• • 09000 Air In i R1°e • • • • • VA 01 • •• •e • e••••e � N r • 4/ry 0000•• • •• 1-8116e • • • •••••• Air out 0000•• •0000• �2-318x 3/16 Oval hole y e •••• • • 7/8of 1110 n oro e••e i 110' /9 handle i 29/32 11-1/4 17/32 Open two sides of left, right,or rear side. 10 N10 N M ti / Liquid pipe :1/4(flared) N 11-29/32 Gas pipe :3/8(flared)(GE09112) 19-11/16 1/2(flared)(GEIS) 31-1/2 2-23/32 1W 623/32 MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite BDulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com s c ug FORM#MSZ-GE12NA-8-MUZ-GEI2NA-201603 Intertek Specifications are subject to change without notice. ®2016 Mitsubishi Electric US,Inc. 77 a ® This combination qualifies for a Federal Energy AM I Efficiency Tax Credit when placed in service between Feb 17 2009 and Dec 31 2016. � r Certificate of Product matimpm AHRI Certified Reference Number: 8626671 Date: 6/8/2016 Product: Split System:Air-Cooled Condensing Unit,Coil with Blower Outdoor Unit Model Number:4TTR6030J1 Indoor Unit Model Number: TEM6AOC36H31+TDR Manufacturer:TRANE Trade/Brand name:TRANE Region:All (AK,AL,AR,AZ,CA,CO,CT, DC, DE, FL,GA, HI, ID,IL, IA,IN,KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY,OH,OK,OR, PA, RI,SC,SD,TN,TX, UT,VA,VT,WA,WV,WI,WY, U.S.Territories) Region Note: Central air conditioners manufactured prior to January 1,2015,are eligible to be installed in all regions until June 30,2016. Beginning July 1,2016,central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. Series name:XR16 • • .. .... 00 Manufacturer responsible for the rating of this system combination Is TRANE •••;•• •' • ""' ...... Rated as follows in accordance with AHRI Standard 210/240.2008 for Unitary Air-CorWitloning and*11,6Source • Heat Pump Equipment and subject-to verification of rating accuracy by AHRI-spondemAlindep'endelnt,third•••• party testing: ' . . Cooling Capacity(Btuh): 29600 :":': •• EER Rating(Cooling): 14.50 • • ..... SEER Rating(Cooling): 17.00 ••• JEER Rating(Cooling): •Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which Indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridlrectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means.except for the user's individual, AM personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The Information for the model cited on this certtflcate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better- and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above,and the Certificate No.,which is listed at bottom right ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 131098874182092582 A °'S00 APPROVED DESIGN PRESSURES. FRANK L.BNNARW,P.E. IC UNIT HOUSING AND ROOF MOUNTING CERTIFICATION 0.5�" ULTIMIATE ALLOWABLE MEAN ROOF CENTROID LIIL 1 'CERTIFIES BOTHUNIT INTEGRITYAND ANCHORAGE TO HOST STRUCTURE FOR WIND RESISTANCE E%POSURE 0750' WIND SPEED WIND SPEED HEIGNit HEIGHT' A/C UNIT DEPTH A/C UNIT WIDTH 1 ...A/C UNIT DEPTH ATTACH ALUMINUM ANGLE TO C 230 FT I (37.29°MAX.) I I (34.29°MAX.) r (37SUPPORTIgO FRAME 3!8'-16 x 1MPH 136 MPH K 7CSS .29°MAX.) HE%HeAO BOLT WITH 7/8'X.040'THICK O 75 D 1 135 FT 1 57' O ® ® WASHER AT TOP ANO 3-%1'X1/8'THICK O "CENTROID HEIGHT IS THE HEIGHT OF THE UNtrS GEOMETRIC cENrao N + BEAR N PLATE WITH 7/6-x.000'THICK 00.250" THE LISTED MEAN ROOF HEIGHT.THE SYSTEM ILLUSTRATED HEREIN IE�QPPAI{�ODVVEE0 WASHER AT BOTTOM WITH 9116*NUI' 1.250° O FOR INSTALLATIONS TO ROOFTOP STANDS BY OTHERS)UP TO 30•IN yEl Ia3G. AT EACH CONNECTION POINT O tMEAN ROOF HEIGHT OF THE BUILDING TO WHICH THE LANIT IS BEmG9Vy0LELE. p N.• Fz (2)3/8"-16%1' 3°%3'X1/8'ALUM.ANGLE FOR AN EXPLANATION OF EXPOSURE CATEGORIES THAT ACCOMPANY pT� L7 BSS HEX HEADOLTS PER ANGLE rATTACHED ro SUPPORTING FRAM' O WIND SPEEDS USED IN THIS DOCUMENT,SEE SECTION 26.7.3 OF 7'.j0`� ®( '?A• ° ` OD GENERAL NOTES sIs 15.00° 15.00" 1 0.75° ''''ry L a 1 .�" ls IS 0.125" .23Y O 1.THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE oil I I S F$ 1 MIN. THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FIFTH EDITION(2014).THIS 'IIQI v o i '1""- OSYSTEM MAY BE USED WITHDI AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE.THE QTIE DOWN 8 DEMON CRITERIA USED TO CALCULATE THE ALLOWABLE ROOF-TOP HEIGHTS CONSIDERS v� m$�a WBRACKETS av0.087' - -r a ASC9 7.10 SECTION 29.5 FDR ROOF TOPHEIGHTS(H)a60 FT.(GC,).'1.90 MSIR@ 0.1=5" ( GCilnusv330MIN. THE HVH2,(G41..v1.5 FOR ALL LOCATIONS CO1'X3'1/8'BEARING WITNiq THE HVH DER FEC 1620.6(CONCURRFM WITH(GC )ALL OTHERDESIGN PLATE AT THE O VARIABLES ARE IN ACCORDANCE WITH ASCE 7.10 CHAPTERS I8 A29. THISDESIGNIS t_ PROD.OF UNDERSIDE OF THE NOT INTENDED TO CERTIFY IMPACT RESISTANCE 0P THE MECHANICAL UNIT CABINETRY.L_____ FLANGE FOR AN OVERALL 0.750"2.NO 33-1/30 INCREASE IN ALLOWABLE STRESS HAS BEEN USED W THE DESIGN OF2IE DOWN 3"x3"xi/6'THICK FLANGE THIaNEsS DF THls srsreMl. ,pD w_BRACKETS -'` - ALUM.ANGLE 0.212'MIN,TYP. 3.DESIGN R CERTIFICATION OF THE UNIT CABINETRY IS APPROVED THROUGH TEST1 40" IN. SUPPORITNG FRAME O R6PORT007o8.01.15 BY AP1eRICANTesrLABOFSOUTH(BY OTHERS) 4.ALL DIMENSIONS AND THE MINIMUM WEIGHT OF ME04WSCAL UNIT SMALL CONFORM EEQ. SUPPORT FRAME EQ. EQ.I 1 EQ.�EQ. TO LIMITATIONS STATED HEREIN.ALL MECHANICAL SP@CIICATIONS(CLEAR SPACE, g BY OTHERS 1 2 R EI N FO RCI N G PLATE TONNAGE,ETC.)SHALL BE AS PER MANUFACTURER REClx4t•1ETUDATIONS AND ARE THE 8 O EXPRESS RESPONSH.11 OF THE CONTRACTOR -- 1 SCALE:6"=V-0° SECTION 0.183" S.ALL SUPPORTING FRAME SHOWN HEREIN SHALL BE BY OTHERS AND IS NOT PART OF Qz THIS CERTIFICATION.A MINIMUM 0.087'THICK ALUMINUM 6063-T6 HIR OR STEEL ( ) NIT LEFT ELEVATION ' I REINFORCEMENT KSI MEN FLANGE 1S REQUIRED.8UE DA TTE N UND A 1'%3'x1 U (9 U 0 UN T FRONT ELEVATION UNIT RIGHT ELEVATION O R8INFORCEM@NT PLATE BNAB@ U8ro AT TEEN GNDHRSIO@ OF 7N8 PLANOH FOR (9 MIN. (2)3"x3"xl/8"THICK ALUMINUM X3 AN OVERALL FLANGE THICKNESS OF o33TNm. cl Ips 0.306"6.ALL SHEET METAL SCREWS USED TO FASTEN BRACKETS TO MECHANICAL UNITS SHALL Z ANGLE ATTACHED PERPENDICULAR 0 pqp° TY BE 010(16 MIN THREADS PER INCH)ASTM F593 410 STAINLESS STEEL OR EQUIVALENT TO SUPPORTING FRAME X2 ONLY.BOLTS USED TO FASTEN ALUMINUM ANGLES TO SUPPORTING FRAME(BY OTHERS) FM.. LEFT SIDE SHALL BE ASTM F593 410 STAINLESS STEEL OR EQUIVALENT AND SAL UTILIZE SAE (. Z LEFT SIDE LEFT SIDE ' I GRADE WASHERS 8 NUTS.PROVIDE(s)PITCHES MINIMUM PAST THE THREAD PLANE FOR tion` #Qd 1.000°{-( SHEET METAL SCREWS.ALL FASTENERS SMALL HAVE APPROMATE CORROSION , --------------- TIE-DOWN BRACKET $HALL PHgVIOf! LAMPREVEETELLR EDGE DISTACTROLYSIS NCE.FASTENER CONNECTIONSCONNECTIONSroALUMugIRA 0 CLIP 2 CUP MIAMI TECH CLIP CUTD14:12G8 7,THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR O ,3T r B.ELECTRICAL AL PREVENTS WHEN RLYSIS. p _ (0.090°)ASTM A653,MIAMI TECH B.�ECTRIGU.GROUND,WHEN REQUIREo,70 BE DESIGNED B INSTALLED BY OTHERS. o KIT 8 TASS830K(FOR MODELS 9.THE ADEQUACY OF ANY EXISTING STRUCTURE To WITHSTAND MNAENPOSED LOADS a }y WHERE DEPTH<33")AND SHALL BE VERIFIED BY THE ONSITE DESIGN PROFESSIONAL AND IS NOT INCLUDED IN W O O W W W THIS CeRTIFICATION.EXCEPT AS EXPREMY PROVIDED HEREIN,NO ADDITIONAL /R O p p RL TASSB36K(FOR MODELS WHERE V B uq1 G O 10. B SEPAR S T RIAL C AFFIRMATIONS ARE INTENDED. U H ♦ y"j ' (/T O LI DEPTH t 33°J 10. BASEPAn MATERIAL CHOPPED FIBER LAMINATE W/FY-15 XSI.PLASTIC Z Fa�ij COMPONENTS USED WITHIN THE HVHZ MUST MEET ALL APPLICABLE MREMIOXE/UV IH r�., 2 eQX p Z tJ > t) PERFORt4ANC9 REQUIREMENTS AS SET FORTH IN THE A00YE•NOTEO BUILDING CODE. O Il. THE SYST061 DETAILED HEREIN 15 GENERIC AND DOES NOT PROVIDE INFORMATION 0y' CONTROL FOR A SPECIFIC SITE.FORME CONDITIONS DIFFERENT FROM THE CONDITIONS S EL DETAILED HEREIN,A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE N SITE SPECIFIC DOCUMENTS NTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 12. WATER-TIGHTNESS OF EXISTING HOST SUBSTRATE SHALL BE THE FULL ppp 0.125" RESPONSIBILITY OF THE INSTALLING CONTRACTOR-CONTRACTOR SHALL ENSURE THAT GG _ ��; _________CUP 4 ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATIONAND INSTALLATION OF STRUCTURE PROPOSED HEREIN.THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAYRIGHT SIDE RIGHT SIDE Yl D'0 RIGHT SIDE 1 -- OCCUR AS WATER-TIGHTNESS SHALL Be THE FILL RESPONSIBILITY OF THE INSTALLING • Y4 T 3.000" CDNTp'ACTDR B PAN TOP VIEW BASIC XI ALUMINUM ANGLE $cq g 37.29°MAX.A/C UNIT DEPTH POINT 6061-T6 APPLICABLE MODELS: �pp� 8� UNIT TOP VIEW SUPPORT FRAME X4 2/4TTA,2/4TTB,4TTR,4TTX,4TTZ,4TTV, , i g d d d ■ R BY OTHERS MIAMI TECH TIE DOWN PLAN VIEW 4TWA,2/4TWB,4TWR,4TWX,4TWZ,4TWV F 2 2 2 @ EEEIII (2)3/8'-16 x 1°SS HEX HEAD BOLT WITH CLIP CUM14:12Ga TRANE UNITS vQ w 7/8•x.040°THICK WASHER AT TOP AND 3"xl"KI/B" (0.090°)ASTM A653 • ••• • O • UNIT wMEWONS 0N) ANCHOR LOCATION DIMENSIONS(IN) THICK BEARING PLATE WITH 7/8"x.040°THICK • • • • • • • • UNIT � 8 WASHER AT BOTTOM WITH 9/16'NU7 PER ANGLE (9)810-16x3/4'410 SS HEX • • •• • •D*GNVM ITEM WEIGHT ttro 1 CLIP Z CLLR 3 um a WASHER HEAD • •• • • • ••• • (IB) WIDTH DEPTH HEIGHT i m y g 8 SELF-DRILLING TEK SCREWS XI Yl X2 Y2 X3 Y3 x4 Y4 ¢Lg�F yg 1/4'-20 x 3/4"SS HEX HEAD THRU BOLT WITH 5/8"x.059'THICK WASHER AT TOP •• ••• ••• • • •• 1 120 25.69 28.42 32.77 6% Y 4% 24'/, 24% 24 Y 23% 1 t q g g AND BOTTOM AND 7/16°NUT AT EACH CONNECTION POINT.ALL BRACKET TO 2 120 25.69 28.42 25.60 69 It 4K 2431, 24% 24%1 2391 1 l>�lWtBitFl•N1 ,0Nm1�8 HOST CONNECTION SHALL BE ATTACHED THROUGH THE ANGLE AND TOP FLANGE 3 120 29.69 32.65 40.70 7 Y Y 4 V mY 28 28 A 27Y IV OF SUPPORT FRAME,EXCEPT THE BRACKET NEXT TO CONTROL PANEL CORNER TYPE XB/XR/xV 15-2530-TR ' PROJECTION OF 3°x3"x118° • • • • a 120 29.69 32.65 28.77 7% Y 4% 2e Y 28 18V 27 V. I Y THICK ALUMINUM ANGLE • • • • • 5 245 34.29 37.29 45.77 8 Y '/e 5 Y 32 Y 32 32Ys 31 1% FACES•>SCRIP m 01. PE7 1 BRACKET CON. DETAIL (6061-T6)-\'� • • • • • • 6 Im 34.29 37.29 29.18 8% % SY, 32Y 32 32% 31 IY PREV.REF. S 1 SCALE:1 1/2'a 1'-0° ELEVATION UNIT PANEUCORNFJt r • • ••• • • ••• 7 302 24.29 27.29 53.86 8 K i 5 Y 3zY 32 32 Y 31 POST.0.035"THICK nvs XL/Film" xv a 120 29.69 32.64 Z. 7It Y 4 Y aeY 20 2e Y x7Y 1Y PAINTED STEEL SUPPORT FRAME BY 9 120 34.29 37.29 41.88 8% Y 5% 32: 32 32 Y 31 1 l�I (Fu-58 KSI MIND _ MIN.TOP(0.087-FIANGETMICK 10 120 29.69 32.66 39.94 7% Y 4 Y 28 • • • • • • • • • • • •• •• • • • •• •• ••• 0 • • ••• 0 •