WS-16-1702 (2) ti��e�Efy
lqc� SPECIALTY ENGINEERING CONSULTANTS,Inc.
�y DADE - BROWARD - PALM BEACH
°7 -7
June 21,2016
Mr.Tom Burnett
Florida Home Improvements
3044 SW 42nd Street
Fort Lauderdale,FL 33312 wS—)f� /70 'L-.
Re: ROMAN RESIDENCE 1310 NE 101 SREET,MIAMI SHORES,FL
DOUBLE 2X8 HEADER BUCK CERTIFICATION
Dear Mr.Burnett:
Pursuant to your request we have reviewed the installation of the double header buck above the new impact
sliding glass door in the dining room(opening#9 on permitted plans)
The new double 2x8 pressure treated southern yellow pine #2 bucks have been installed in the following
manner:
*The first 2x8 buck has been installed with 1/4"�x 3-1/4" Ultracons at 6" on center, staggered, and(2)within
3"of each end.
*The second 2x8 buck has been installed with 1/4" 0 x 6" Ultracons at 6" on center and (2) within 3" of each
end.
All the Ultracon anchors meet the minimum required 2-1/2"edge distance and 1-3/4"embedment
We find that this installation is in compliance with the 2014 Florida Building Code and can safely support the
design loads.
We hope that you find this information helpful and should you have any questions please feel free to call on us.
r ..
Resp ul4tm
ecialtng , C.
D. 4�16 Spencer Ledgard,EI
to ions �' ` °� ZJ Project Engineer
cor . � �°
ON
State of Florida: 9
� 3uPe�� 9
Registered Professional Engineer: #077012
Certificate of Authorization: #009217
1599 SW 30d'Avenue,Suite 20 - Boynton Beach,FL 33426 - Office:561-752-5440 - Fax:561-752-5542