Loading...
WS-16-1302 ,NE, , WS-6 W. SPECIALTY ENGINEERING CONSULTANTS,Inc. a $ DADE - BROWARD - PALM BEACH '�u 1 is June 21,2016 Mr.Tom Burnett Florida Home Improvements 3044 SW 42nd Street Fort Lauderdale,FL 33312 Re: ROMAN RESIDENCE 1310 NE 101 SKEET,MIAMI SHORES,FL DOUBLE 2X8 HEADER BUCK CERTIFICATION Dear Mr.Burnett: Pursuant to your request we have reviewed the installation of the double header buck above the new impact sliding glass door in the dining room(opening#9 on permitted plans) The new double 2x8 pressure treated southern yellow pine #2 bucks have been installed in the following manner: *The first 2x8 buck has been installed with 1/4"0 x 3-1/4" Ultracons at 6" on center, staggered, and(2)within 3" of each end. *The second 2x8 buck has been installed with 1/4" 0 x 6" Ultracons at 6" on center and(2) within 3" of each end. All the Ultracon anchors meet the minimum required 2-1/2"edge distance and 1-3/4"embedment We find that this installation is in compliance with the 2014 Florida Building Code and can safely support the design loads. We hope thatyoulf� Ws`"mformation helpful and should you have any questions please feel free to call on us. Respectfuljy'o ^m*ed ° Spe ' e�n - mei : D. L lanc,PE, �' '�°•�e Spencer Ledgard,EI for of Project Engineer State of Florida: Registered Professional Engineer: #077012 Certificate of Authorization: #009217 1599 SW 30`h Avenue,Suite 20 - Boynton Beach,FL 33426 - Office:561-752-5440 - Fax:561-752-5542