WS-16-1302 ,NE, , WS-6
W.
SPECIALTY ENGINEERING CONSULTANTS,Inc.
a
$ DADE - BROWARD - PALM BEACH
'�u 1
is
June 21,2016
Mr.Tom Burnett
Florida Home Improvements
3044 SW 42nd Street
Fort Lauderdale,FL 33312
Re: ROMAN RESIDENCE 1310 NE 101 SKEET,MIAMI SHORES,FL
DOUBLE 2X8 HEADER BUCK CERTIFICATION
Dear Mr.Burnett:
Pursuant to your request we have reviewed the installation of the double header buck above the new impact
sliding glass door in the dining room(opening#9 on permitted plans)
The new double 2x8 pressure treated southern yellow pine #2 bucks have been installed in the following
manner:
*The first 2x8 buck has been installed with 1/4"0 x 3-1/4" Ultracons at 6" on center, staggered, and(2)within
3" of each end.
*The second 2x8 buck has been installed with 1/4" 0 x 6" Ultracons at 6" on center and(2) within 3" of each
end.
All the Ultracon anchors meet the minimum required 2-1/2"edge distance and 1-3/4"embedment
We find that this installation is in compliance with the 2014 Florida Building Code and can safely support the
design loads.
We hope thatyoulf� Ws`"mformation helpful and should you have any questions please feel free to call on us.
Respectfuljy'o ^m*ed °
Spe ' e�n
- mei :
D. L lanc,PE, �' '�°•�e Spencer Ledgard,EI
for of Project Engineer
State of Florida:
Registered Professional Engineer: #077012
Certificate of Authorization: #009217
1599 SW 30`h Avenue,Suite 20 - Boynton Beach,FL 33426 - Office:561-752-5440 - Fax:561-752-5542