Loading...
BPP-15-1590 Miami Shores Village i t.. E 10050 N.E.2nd Avenue NE Miami Shores,FL 33138-0000 Phone: (305)795-2204 Expiration: 03116/2016 Project Address Parcel Number Applicant 1481 NE 104 Street 1122320320090 Miami Shores, FL 33138-2663 Block: Lot: JAMES$MAR BREEN Owner Information Address Phone Cell JAMES&MAR BREEN 1481 NE 104 Street (786)617-3500 MIAMI SHORES FL 33138- 1481 NE 104 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone $ 25,000.00 VAN KIRK&SONS INC (954)755-4402 (786)326-2747 Valuation: Total Sq Feet: 450 Approved:In Review Available Inspections: Comments: Inspection Type: Date Approved::In Review Fence Date Denied: Final Type of Work:Swimming Pool Occupancy:Private Pool Deck Additional Info:NEW SWIMMING POOL 15X3U GALLONS Bond Return: Wall Steel Classification:Residential Scanning:4 Review Electrical Review Electrical Review Planning Review Planning Review Planning Review Planning Review Planning Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Review Plumbing Bond Type-Contractors Bond $500.00 Review Plumbing CCF $15.00 Invoice# BPP-6-15-56124 Review Plumbing CO/CC Fee $50.00 09/18/2015 Check#:40013 $1,564.50 $50.00 Review Plumbing DBPR Fee $11.25 06/26/2015 Check#:39764 $50.00 $0.00 Review Building DCA Fee $11.25 Bond#:2843 Review Building Education Surcharge $5.00 Review Building Permit Fee $750.00 Review Building Pian Review Fee(Engineer) $160.00 Review Structural Pian Review Fee(Engineer) $80.00 Review Structural Scanning Fee $12.00 Technology Fee $20.00 Total: $1,614.50 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDA rtify that all regoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an on' g Futhermore auth the above-named contractor to do the work stated. September 18,2015 A Date Building Department Copy September 18,2015 1 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-237735 Permit Number: BPP-6-15-1590 Inspection Date: May 05,2016 Permit Type: Pools/WhirlpoolslHot Tubs Inspector: Naranjo, Ismael Inspection Type: Final Owner: BREEN,JAMES&MAR Work Classification: New Job Address:1481 NE 104 Street Miami Shores, FL 33138-2663 Phone Number (786)617-3500 Parcel Number 1122320320090 Project: <NONE> Contractor: VAN KIRK&SONS INC Phone: (954)755-4402 Building Department Comments NEW SWIMMING POOL 15X30'GALLONS AND DECK InfPassed Comments PAVER ON SAND INSSPEPE CTOR COMMENTS False 06-29-15 I. Naranjo Hold No reviews until zoning corrections are made. ,Jnspector Comments Passed Failed El Correction a Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. For Inspections please call: (305)762-4949 June 15,2016 Page 1 of 1 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 inspection Number: INSP-257985 Permit Number: BPP-6-15-1590 Inspection Date: May 02,2016 Permit Type: Pools/Whirlpools/Hot Tubs Inspector: Dacquisto, David Inspection Type: Survey Final Owner: BREEN,JAMES&MAR Work Classification: New Job Address:1481 NE 104 Street Miami Shores, FL 33138-2663 Phone Number (786)617-3500 Parcel Number 1122320320090 Project: <NONE> Contractor: VAN KIRK&SONS INC Phone: (954)755-4402 Building Department Comments NEW SWIMMING POOL 15X30'GALLONS AND DECK Infractio Passed Comments PAVER ON SAND INSPECTOR COMMENTS False 06-29-15 I. Naranjo Hold No reviews until zoning corrections are made. 2 /6 Inspector Comments � / /r Passed J l 41elq..1 , cry /W,2 . s - Failed El Correction Needed Re-Inspection Fee No Additional Inspections can be scheduled until re-inspection fee is paid. For Inspections please call:(305)762-4949 May 02,2016 Page 1 of 1 Miami ShoresVillage g Building Department BY: 2Tel: 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 (305)795-2204 Fax:(305)756-8972 -71 INSPECTION LINE PHONE NUMBER:(305)762-4949 20 l� BUILDING Master Permit N BC PERMIT APPLICATION Sub Permit No. S-A/BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1481 NE 104th Street City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel#: 11-2232-032-0090 Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): James Breen Phone#:786-617-3500 Address: 1481 NE 104th Street City: Miami Shores State: FL Zip: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Van Kirk&Sons Inc. Phone#: 954-755-4402 Address: 3144 SW 13th Drive City: Deerfield Beach State: Florida Zip: 33442 Qualifier Name: Robert P. Van Kirk Jr. Phone#: 954-755-4402 State Certification or Registration#: COC-045956 Certifica «of Competency#: r � . • 6 DESIGNER:Architect/Engineer: Phone#: /� .,II11 Address: � � �.� • ��Z plq[. City: .jt[ State Zip:3*5 Value of Work for this Permit:$ �j Square/Unear Footage of Work: LI.S"D Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: 12 of Specify color of color thru tile. Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) o � Bonding Company's Name(if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT 'IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not beappro and a reinspection fee will be charged. Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument pias acknowledged before me this day of 20 �`..7 .by d of 20 by �/ t - wh s personally yvho is personally known t ail 6: ° G e or-wFro has produced as me or who has produced as identification and who 8id'take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign. —���^ Sign: Print: ROBERT VAN KIRK,III Print: TARP F>UBUC a $may fg +MY`COMMISSION#FF126798 Seal: STATE OF FLORIDA Seale' EXPIRES May 28,2018 • ?. Expires Cornm#FFR" 6/7/2017 (407)39sat5s FloddeNotaryservim-com gee**ess•*e*+r:e+***+pass*cess*a�xs �s** **wx�e**yeas*►►*x�se**a�a**►*****es*see••*sr•e�ea*ee*ww�eeae�b*eeese�s*e•rs APPROVED BY Plans Examiner Zoning /J�C/")J v Structural Review Clerk (Revised02/24/2014) 7 ( I, . O Miami shores Village Building Department 10050 N.E.2nd Avenue �jpRIDp Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL,SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub,will be constructed or Installed at 1481 NE 104th Street Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet'the requirements of Chapter 515, .Florida Statues and the Florida Building Code R4101.17. Please Initial the methods)to be used: The pool will be equipped with an approved safety pool cover that comp lies with ASTM F1346-91.(Submit Manufacturer's Specifications). A continuous,one-piece(child)barrier meeting the requirements of Florida Building Code R4101.17.1.15 will protect the pool perimeter.The plans shall show the fence location and method of attachment,including one end that shall nbt be removable without the aid of tools.(Submit Manufacturer's Specifications). A combination of non-dwelling walls and fences(screen enclosure,child felce,dasonry•""• ••e%• fence walls,chain link or wood fence,etc.)will protect the.pool perimeter.The plans mush 1Sgecify t he tyee:•• •. . .. . . ...... and location of all non dwelling walls.Florida Building Code,84101.17.1 •••:•• • Any combination of protection which incorporates dwelling walls with openir%F•ji ectly into the•• ••••• pool perimeter and all windows and doors will be equipped with exit alarms complying w4FJOrW Building•• ••;••• Code,R4101.17.1.9(Submit Manufacturer's Specifications). ..•..• : ...... �Any combination of protection which incorporates dwelling walls with openirSgs�r*tly inti;the, •.•„• pool perimeter and all doors will be equipped with a self-latching device with positive meohanical :00090 latching/locking installed a min.54”above the threshold. If this option is selected,submit piartrs Aowing all :••••: types and location of all perimeter protection.The plans must also show the location and type of all •• • openings,and the hardware type for each location.(Submit Manufacturer's Specifications). In accordance with the Code,the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements,and upon expiratloo of the permit,the pool shall be presumed to be unsafe.I understand that not having one of theAbove installed w111 constitute a violation of Chapter 515,F.S.,an d will be considered as com Ing a misdemeanor of the second degree,punishable as provided in Section 775.082 or Section 5.083 .S.This form ust be signed by the o agt and then contractor. \ r� CTRACTOR'S SIGN URE AND DATE 0 'S SIGNATURE AND DATE /011 Robert P. Van Kirk Jr Ann e 5 L 0 TRACTOR'S N LEASE PRINT) OWNER'S NAME(PLEASE PRINT NOTARY U y^.p"". euwc �• FtYSTAL N JONES STATE OF FLORIPA Y COMMISSION#FF126M . C EXPIRES May 28,2018 fi ao� olt33 Flond�Not seM09.00m , t a SNoREs Miami Shores Village 'ewes Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 LORiUA Tel: (305) 795.2204 Fax: (305) 756.8972 SURVEY AFFIDAVIT STATE OF(FLORIDA) COUNTY OF(DADE) The undersigned Affiant, James Breen does hereby attest that (Property owner) The attached survey,performed by 0000 (Name of surveyor's company) •••• 0.00.. •• • 1481 N E 104th Street •••• For address: ...••• •••• ••••�• 0000.. 0000.. 0000 V. . Performed on (date of survey)is an accurate representation of the existing contliftris and. •• ••:•'. - 0000.0 00:04, 0000. locations of all structures on the property as of this date. ..•0 0• ••• •••••• The purpose of this Affidavit is to induce Miami Shores Village to issue a building je*r*m*%r the•prohrty •• „� 00.0.0 without first providing a survey less than seven (7) years old old. The Affiant, as property other,%rther tgrees to :0000: .. 0000 remove or obtain permits for any structures which now may exist on the property which are not permitted oFJON& may violate zoning or building code regulations. The Affiant further understands that the existence of any such structures m affectfin I inspections as applicable to this or other permits. Further,A nt say naught. tt►► Pr Owner Signature Property Owner Print Name SWORN TO AND SUBSCRIBED before me this� day of LA," SIDS Affiant is_personally known to me, produced as identification. N04%BERT VAN MRK,III Revised on 5!22@009/Revised on 6/12119 NOTARY PUBLBO ). Ejq*es STATE OF FLORIDA CQMM#FF006W &712D17 t 5t;ORE ,,,, q,,,M Miami Shores Village Building Department �IpR�UA 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION Date —4= _;! Miami Shores Village Building &Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as 0000 River Bay Park , located at 1481 NE 1WLI-Street...• .••••• • 0000.. • 0000.. :0000: In accordance with Section 33-12(f), Code of Metropolitan Dade County,j rortify tt5t I;• ;••••• understand and agree that the swimming pool to be constructed at the above.Addtess cipAN ; • be used or filled with water until separate permit has been obtained for an approvbd safety:• 0.000"0 • • barrier, and such barrier erected, inspected and approved. •••• •• ;•; :'•••: I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. Legal Owner Note:This certification is to be submitted with a swimming pool permit application in duplicate. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 p Tel: (305) 795.2204 Fax: (305) 756.8972 PREPARED BY: DECLARATION OF USE KNOW ALL MEN BY THESE PRESENTS: WHEREAS,the undersigned James Breen Ware the fee simple owners)of the following described property(°Property' situated and being in Miami Shores Village,Florida: Lofts) 10&11 Block 3 of River Bay Park (Subdivision),according to the plat thereof,as recorded in the Plat Book 40 Page 72 of the Public Records of MiamaDade County,Florida,(address) 1481 NE 104th Street and WHEREAS,the undersigned owners)have sought certain development approval from Miami Shores and are providing this document in consideration thereof and to induce the Village to grant same: NOW,THEREFORE,for good and valuable consideration,the receipt and sufficiency of which is acknowledged,the undersigned do(es)hereby declare and agree: 1. That the Property will not be used in violation of any ordinance of Miami Shores Village or Miami-Dade County now in effect or hereinafter enacted. 2. That the property will be used for a single family residence only. 3. That he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by.994arn Viand • • •••• •••••• conditions set forth herein. • • i • • •• FURTHER,the undersigned declare(s)that this covenant is intended and shall constitute a restrictive covenant concerning th%wos,#y)oymeri ft tMe 0 the • 0 •••••• above Property and shall constitute a covenant running with the land and shall be binding upon the undersigned,his/her successors and ft"Ifid may only begeleased e • by Miami Shores Village,or its successors,in accordance with the codes,rules and regulations of said Village then in effect •AAS 00 •00 0• IN WITNESS WHEREOF,the undersigned hasthave caused hand(s)and seal(s)to be affixed hereto on thisLAU of • • • • ••••• •• •• •• • •••••• NERS• � • WITNESS(ES) • 0&s o:0 ••••• Signature Signature see. • • s•eV-and • Print and Print ' Signature60FIp" ROBERT VAN IORK III Sign re NOTARY PUBLIC and PrintF Iq EMMA and Print III STATE 0C=M#FF NOTARY IPUBUO COUNTY &7=1 STATE OF FLMDA 0 I HEREBY CERTIFY that on this day personally appeared before me who is perso a ty kn me or has produced (type of identification)as identification and he/she acknowledge that he/she executed the foregoing,freely and voluntarily,for purposes therein expressed. SWORN TO AND SUBSCRIBED before me on thi a5L day of CRYSTAL N JONES IA My commission expires: * /• MY COMMISSION#FF126798 EXPIRES May 28,2018 ARY PUBLIC,S OF FLORIDA (407)398.0153 FloridallotwyService com A 6£9991:•oN IWO '03 -AeNMV21a ,oz=.6.37VoS 31 mut t31Va a731 790,ONNO11Va1S103a OL'f, ='d'x'3` a3ddMGNVNOA3nanS7VNOlSS3dOadVG14O74 Z5'9=A373 30VHVf) or Oa4'!'Vd j OOS/ONVad nOO 30dO-lWd/W Olt = %1373 b2l-9Z-8# 'W'8 0£5Z Z�6(50£)Xd� 606L-999 (50£)Hd -3rcaeanrv3-c%a37MONN OV9 =3GVHD 1N3OVrGV IS3MO7 ft£6££vGlHO7d `S37Gva IV800 My 1s338u auo--woo 0Nv3na1 '6Z66 'OWOW O-L U3d3Z1 NMOHS SN0/1VA373 si ow S--UM s VClydO-d 3HL do LZOZik U3JdvHo •d9ddM ONv ao"uns NOIlb�/13 i3 Z1007d 378b'118b�H 1S3M07 S310N 69'9 _ %137 �'7 0 mins-3702110 b418WV/HlV 58£ , aL mmsrand a3oomsv ma Wwmudas O3SN3on VOrNO7d V do 7V3S 03SM 7VM�JRIo (213/d17vnt))1-9LP#WSd OOMdI'dd v 00SIONta2Jd $ N1 Sa3ddM ONV SHOAMUnS 7VNOlsS_%oNd 31-u aNV 32WaLMOIS 3H11nOH11M OnVA ION 6266(MO 00'6+ =%1373 3SVG 8602#87 doOavos'Swm3Sa3wnSNOoaNV 60OZ-66-60 :WNId d0 31V C1 L 9v'=33N OVVaammav(o�)u-s sMdOaV 3►n r 8£6££t/Qli`J07d `S3ZlOHS IW d/W JNl V/Jcl bb.J T S3NNV-7 :xiddnS o3Nnlno sv`varao7d�ro 31v1s 3Ht NiNI oNu3nans 133ZI1S 41i�06 '3'N 68t�6 Z590Z6 :'oN�t.LINllWWO� avv7do sauv NVIS 7Vonw-- immiNn 3H1 ON/ddVPV GNd ONMAyns 7MOISSM(Odd WSMO,4NOOA3Wf)SSOU IV i.cJUSMAH3a3Hr 90£0098026 =73NVd T dVYi A3MMS AUVaNn09 d N33�I8 2/bW QNd N33218 S3Wb'!':d0�t L�13dO�ld 3d:3NOZ 0007d ',• :`v*� ,.•,°iat -'.,,,5 F - .�- ;- ,� '' S�:i"a- 'tij .;,:.y 1/19yY3SY3.Unl1/1 s •� 3'n 3M/UY� d01N10d OOd 1NVMONr32lE! 7rd _ F. NOUO3�W0:7.LN3YYMYd30 R - � z,yni ,,�, . .<� � g-•, vv� ��=i:`". r•?,::•$,: . �' �s, ,,� _ )��,,,,s�,y";. a ,n.,:v,'°, L }. • ,�,: -',n s �'CS}l q. Y >.1'. _ v"a. : 1.. .:-dh� r. `4 3Mn1X/dENVLLHDn 7YOldtl dAL 3MnLYAMRO�lAIJOd Od 21007dHSdINd d'd �- :� � ::'; ',_ '.:. � �. J � ,. *e ':*'� - � __.� -� <: ._� ,,,.;',��h`S :r+�^•�s a ^r ,..,.- �YOHd373L 73L S3NnA117LLROV3H2BA0 n lAYOdMNOUVA373 d7r33 vi;"G t ,w�, u�f {f: c•: x lAIVMOA/r.3Mt� Two ;.� v � .� +�^,rr,L. ,.:,,:�k•1,eo`+v _; ,.°-•�_.:�",' � �.,�� i n r z. m i�;a; �' � u>4S a.+- v� � pfYt 37MMMAYMN09 )&WHOAWAMVMOdAM (12'9'1 3M7.t1LSdOLdNO UNO JASHROYOU30 WON3 370HNVW30YN/VMQ 1NdJlYYl 1 N009CTM003M7Vp1330 8?f0 AO/1Vi1373 %L3A � : Y avFwSa:x�-':�"` i` '�,i,v.` ?`{ 'ir _^Y • .t h:«: 'x:r 'k^ � ,:.a; ,. 133L•ILS us 97WJSO110N NDIS S1N X�OI2I1O373 93 Qp ��' .s?. ;�1�8xc �y'=�� ,�riu.t., r r^''f3` :*�`":+'�,..' .}�." '�',{-s,�" .Y `. . au,97 a��"�t� �-r' two - '7� �� -,✓ .- `� O _ r ..,.!. ` 'itis '- 3:i i r';. .i �' F•- x.�Pt. a �: +, �b.��., '" 3A'7VAhMVM N OOMN02d13S Yrs 2r YnN ON 1nONd37O _NMYAYW- VHOa-7SOd02d®'+ 3dldNOM13s dY'S 378JUAe01oNpON 313MONOO y } •; '' r d y__, :n� us: t l t=_ . c r_ L " •,. r'. NOLLVA37330YWVNLL$A3 096 AMJWW NYS Wn1YO7V-'W AOU3O03O7VNOUYNOAON W37D 'lO p _ _ - a k „+u :_ c < y r Mo'7d2/3LYM AYM-iO.1H01M Mol MUM 7VOUM3ANYO1M3NNH MW aAbON 3 y /I�YJ�00L �u h ALH7dOMd i0� NOUYA373NNM 3b 03MnSY�W (VIII lO r 7 y 3ON3d000M OMOo� (2d XOA34hMONV7 S7 :WAW mw $ AVM)/YVC(IN r S 3ON3d3MGN —r— snalva M ss3Niswa-ewn 97 301W1310 HO /��� t! ,_ :..,, G-MAIMLn amiew AOA30lW1dOlNlOd Td 370diHOn d7 DA MV3 MOV 9HO !O/.000DL 7170 :, s3 % d R M Ino 313MONOO JAC-V#VlM-:?OA31GaU1AGMVA2f3d WWd 7VW7 (7) 3MnLOnHJA9)W783-Q9M O SW -WUVUMWOW 7 UMVO 'OAnMN ld/M { O91Nils s7 1M40LNIOd M'O'd m11110J X08Af0lSYA3731319VJ ALPO ,^ ,..• W RL J/7GM30/S ONDO, _-.,._:.,._-..:.._..::..,._..'.. ...2) ,00 056 1S3/I OMA9VffJ38dO1N10d 8Od OONNOWaNnOJ �NWHOA38 � �,...._..,..,.._.,a.,.....,_.:.:..:_...:.......:.....:...................................:..:.::.....,.,..:u:: _ U9d Ud 7d MION/>0J drd OkYA37/T09 OA7B .off O(ON 3d/dNOON O/ON MA 37odAU7Un 000M'd-n-m LGddw M/NOA3A&M 7VNOlSS3d021d Fi3d 1H017 9 M3MOd VGW7d 7dd 3nmmv 3AY a, OZ/d%j ,Z 3AWAU31VM AM MOA9 MRS ONV77VNO/SS3d02W M3d/dNOM ill �2//V OA+ .Z// �l%� .Z/d/� '� � / 2L IM2:31YM PWM 1MOd70MLNOO,UIWMW3d irOd 3AWA70WOONOLLY01W A'07 M9937 I 0 6-107-40 v ?YgMYOO MS 1S3M=I-9MUS WOt 3N dO AVM , I j01HJfa H1aON 1V NW(7lb9YilV7d 03WnSSV NO 03SV9 Sad NMOHSANV jI SJNMV38(Zt `WSW 2/VW(INV N33218 S3NVr ";,; . SdM 31Va NOLLVPVUOdN/0007.EAON30V :AWWV00 3ONV21nSN1 IN3Pi-MVNV6YAON3Ja3W3 7Va303d PVOW 03AM30 SVM NOLLVMOjN!3NOZ 0007](tt 371u-"ouVN onond3M a7O .tJO ALIHV70 HOd 031Va399VX3 Yd?V30709 7 83W621N 771�A2 4 •:. S8 .9 39AVW S3NnAl2l3dOad ONV S3ON3d 210/ONV S77VM N33ML3830NV1S/O JNIMvwa(0t '77VM dO 3OVd WOad/013av s1N31N3ansvan 77VM(6 '�-� 3MN1 d0 a3LN30 013aV SMN3d 3a/44 Ol SJNMERMSvsm(8 wacre 0310N3S/wewo sS37Nn 03NIWN313alONdHsa3NM03ON3d U S-X0078 L" OL I/-107 '6Z6tiNn1VO7VOLLa3A0/13003)7VNO/1VNNOa3SV832WNMOHSdlS73NOLLVA3 (9 Sd31S D•9 37/1 /. 3a3M Awdl sm3pmoadmi a3H10 a0 SNOUVONnod S3LLnLLnONnoveJ eaNn(9 .9� 7roly w/ 17 7d mom d0 30(smo 013aV smmu aOOM 01 sIN3W3anSV3(N(4 NO2!/f'NO 'ON003a d01V7d AIb9dOad.9 LL NO NMOHS ION saomwennON3 a30a0O3a 2l3H10 210 S1N3W3SV3 2104 031OV2/1S8V lON 32I3M N03213H NMOHS S3LLa3d021d(E 7cUA/O 90< ,ogy Sa3H10 AS 03a(AOad A101MM1OS3a W937(Z /q .00Y N(S 77DM77VM 8 �Y� f-}0078S03anS ONV7 03231SIJ3a3H1 FLN 03S08M3SI3an1NJ1SSS37Nn 07VAlOo S83, JS6-7'9 6-107 �s ION SAFOA3AunS c /ts8=��/ .( 1S o tvo0 WWo r-XOO78 w e 0 3jN30/S3�1 w a •dardo73`A.LNnoo Sava-moo do saao03Mz!-107 �D A S FX 7 o179nd 3H130 ZL 3JVd`OP,H0081V7d NI a3a210o321 SV=10983H1 lV7d Aa p ON07 31 V9 3H1 Ol JN/a21000V.NOWCIGV MHVd AVG 213A/26,'00079't`t t aNV 06 5107 � � ��,< N081,9 � W =NO11dlMOS30 711')37 sioz ® s inr .OBL1d ,09 98 E6 fA C�1 � ,oa.r< 9Y< ,00< w Z8 ?131NV7d w g .9Z< .t993< ONOO 149Y: 62WV 77DM p� 7d.s 3711' V SBO B . If' _„___s ;...-----•-----• i i 1 i • • -• • • • •• w •p s• • •� • • a•,�1. 'Jk7N0,7; 77VM ”a".............----•--•--._...._... ..........._........•..._....__._.••- • • • • • �o � • • • • • •:;• M • r • • • • • .� • • .! • • •• • s S83.S r 6 a ra w c at a , « c p ,. e c • • • %: • O �Tt • ••• ♦ s i-:• i i .'i • - i6 bot W �• r-X')078 ` r 0/-107 a u a: a n c, �► c l v c ro c e F •� t°•' • • • I • • ( • ••• • O i I iii •; • 4X.0! •�c p� s� • • • • sa r--, -WOO _.:_. __ _.__..___�� _._-c—tit= :• •...• • • • 7d/NO •Ot"E< E. .09Y�< '•• ••: • ••• •: :•• dOVO 37oH 77DM6>3S o/v03./ (W'8al),00"056 Lsvg � 370H 371�OS 01 ION ':' : : : : ':' : : ,� • ••• • ••• 77ir�a 'ON-4 77ibo oN� ' 7VfNV'O iQVi/v" lO�AbOSLS HOLMS NOILVOO : :•••: : : :.•.: M/gAub *L02 low.: t � James F. Biagi PE Consulting Engineer Date: December 10, 2015 City of Miami Shores Building Department Miami Shores, FL RE: Street Address: 1481 NE 100 Street., Miami Shores, FL Helical Pile Log. Breen Residence Dear Building Department: On September 9 20151 observed the placement of helical piles at the address referenced above. The piles were set to a 15 Ton Capacity.This Is the capacity required by the pool design engineer. My log Is attached showing the required torque on the top of the helix. (6888 ft/lbs).A torque chart is attached for the calibration of the placement machine.The chart explains the ultimate load as 30 ton or 60,000 ft lbs.The allowable load Is%the ultimate or 15 Tons and the required torque to get the 15 Ton Is 6888 ft lbs.which was the minimum observed on the meter. very tt'e +� e�eee. 9.-- V 0. 3.�ames F. Biigii, P.E. F1*377 F .. ........ 1 17 �e'd�1'�N A,1�1�,�9•,4 1915 NE 45TH STREET,SUITE#107 FT.LAUDERDALE,FL 33308 PHIFAX 954 776 8004 � pq ori 0 `�Addgbtbttft'f//y j: F• Bill 7 3?467 •:o All�S� /�/rftr�tbeee�s HELICAL PIERS INSTALLATION LOG Cr. Plies I.D. Type of Specified Torque Installed Torque Penetration Number&Size No: No: Pier (Ft.Lbs): (FLLbs): (ft): of helical: Kips: 9/2912019 1 P-1 Helical 6888(2100) 6888 25 12" 14" 30 Plate 2 P-2 Helical 6888(2100) 6888 26 12" 14" 30 Plate 3 P-3 Helical 6888(2100) 6888 27 12" 14" 30 Plate C P-4 Helical 6888(2100) 6888 23 12" 14" 30 Plate 5 P-5 Helical 6888(2100) 6888 24 12" 14" 30 Plate F P-6 Helical 6888(2100) 6888 25 12" 14" 30 Plate P-7 Helical 6888(2100) 6888 26 12" 14" 30 Plate P-8 Helical 6888(2100) 6888 24 12" 14" 30 Plate P-9 Helical 6888(2100) 6888 25 12" 14" 30 Plate P-10 Helical 6888(2100) 6888 25 12" 14" 30 Plate 11 12 13 14 15 16 17 18 19 20 Project: Breen Residence Load: 15 Tons ®��®�V�� •F•� i,�',/ ° `G� F•'•° �e Contractor: van Kirk&sons Misc. Info: Piate 6 X 8 X 112"w12#5 Hook Bars e • �N 467 m _ Addraw 1481 HE 104th Street Miami Shores / a /ON EASTCOAST TESTING $ ENGINEERING, INC. 4100 North Poweriine Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#954-9718872 ESTABLISHED 1981 ETE@BELLSOUTH.NET December 01, 2015 Bodax Foundations, Inc. 1101 NW 55th St Fort Lauderdale FL 33309 Re: 1481 NE 1040 Street Miami Shores, Florida Dade County, Florida Dear Mr. Rich Barnes; As requested,EastCoast Testing 8 Engineering,Inc.performed a subsurface Investigation and engineer evaluation at the above referenced project In accordance with standard geotechnical engineering and subsoil properties within the industry,it was recommended to utilize helical piers, (12-14") for deep foundation design. The recommended approximate depth for 15 ton bearing capacity was estimated at+1--28.0 feet below the existing grade. It should be noted that helical plies shall be Installed to approximate depths Into suitable soil bearing stratum as determined by the geotechnical engineer and/or local jurisdictional authority. The torque correlated capacities are based on Installing the pile to its torque rating, using a consistent rate of advance and rpm. The capacity is based on well documented correlations with Installation torque,which Is recognized as one method to determine bearing capacity,(IBC Section 1810.3.3.1.9). A minimum safety factor of 2 Is used for determining the allowable bearing capacity from correlations. Axial deflections of 0.25 to 0.50 Inches are typical at allowable capacity. Due to the porosity,density,shear strength,soil cohesion,granular friction angle,and other properties of the limestone substratum encountered,depth of the helicals from one point to another,and/or one site to another can vary considerably. Helical screw pile systems must be considered a deep foundation elemen4 and as such,as a rule In thumb,Installed to a depth of at least six,(6)tines the diameter of the largest helix. Should you require further assistance with this or any other project;please do not hesitate to call on us. Respectfully Submitted, EASTCOAST TESTING&ENGINEERING,INC., CertlflCate ofAnIhortration#3425 12/1/2015 Mohammed A:Rai,P.E. Craig Smith,President Senior Geotechnical Engineer State of Florida#59345 wpdocs.►bodaxlt csmh THRESHOLD/SPECIAL INSPECTIONS,BORINGS.DENSITY. CONCRETE.ASPHALT.ETC,A"GEOTECHNICAL TESTING LAB" M .... �. Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 MIAMI SHORES VILLAGE NOTICE TO BUILDING DEPARTMENT . OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER THE FLORIDA BUILDING CODE I(We)have been retained by to perform special inspector serer under the Florida Building Cade at the __ 113 -sy, project on the below listed structures as of =7 W d S(date).I am a registered architect or professional engineer licensed in the State of Florida. PROCESS NUMBERS: ID SPECIAL INSPECTOR FOR PILING,FBC 1822.1.20(R4404.6.1.20) 0 SPECIAL INSPECTOR FOR TRUSSES>35'LONG OR W HIGH 2319.17.2.4.2(R4409.6.17.2.4.2) d SPECIAL INSPECTOR FOR REINFORCED MASONRY,FBC 21224(R4407.5.4) Cil SPECIAL INSPECTOR FOR STEEL CONNECTIONS,FBC 2218.2(R4408.5.2) • SPECIAL INSPECTOR FOR SOIL COMPACTION,FBC 1824:3.1(84404.4.3.1) 13 SPECIAL INSPECTOR FOR PRECAST UNITS&ATTACHMENTS,FBC 1927.12(84405.9.12) o SPECIAL INSPECTOR FOR Note.Only the r fed boxes apply. 1 he following individual(s)employed by this firm or me are authorized representatives to perform inspection' 2. _ `i► smrrW 3. C > Arial �taad .�Y 4 MAROLD &Xr*W "Special Inspectors utilizing authorized representatives shag insure the authorized representative is qualified by education or licensure to perform the duties assigned by the Spew Inspector. The qualifications shall include licensure as a professional engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation frau an architectural education program;successful completion of the NCEES Fundamental Examination;or registration as building Inspector or general contractor. 1,(we)will notify Miami Shores Vftge Building Department of any changes regarding authorized personne:perming inspeetion• ...... services. •• • •• • • I,(we)understand that a Special Inspector inspection log for each building must be displayed in a convenINLO ion on the site for reference by the Miami Shores Village Building Department Inspector.All mandatory inspections, as n;WItqd by the Florida :....: Building Code,must be performed by the County.The Village building inspections must be caged for on allfMfery inspeetimae ' Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspegt%WrformW by the Department.Further,upon completion of the work under each Building Permit I will submit to the Building k$War at the time or ""'• final inspection the completed inspection log form and a sealed statement indicating that,to the best of my jvjgv ftdge,be�'ie{and "";• professional judgment those portions of the project outlined above meet the intent of the Florida ButttdingoCgde and are in '. substantial accordance with the approved plans. • ...... •••••• Signed and Sealed EngineedArchkoctime ' .. (PW • Address-4b0r5PJ4 ll1& d 40•L 7/27/2015 POWA O ftAcg P$„ 33M3 DATE: Phone No. qr4. 171 X.'I&-4S Created on 6/10/2009 EASTCOAST TESTING & ENGINEERING, INC. 4100 North Powerline Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#954-9718872 ESTABLISHED 1981 ETE@BELLSOUTH.NET February 15,2015 Report of Engineering Evaluation for.James Breen Project :Proposed Pool Location : 1481 NE 100 Street Miami Shores,Florida Dade County,Florida To Whom it May Concern; As per your request EastCoast Testing S Engineering,Inc.performed the modifled and standard penetration test boring's at the above reference location. The purpose of this investigation was to provide Information concerning the site and subsurface conditions In order to provide site preparation and foundation design recommendations for support of the proposed construction. This report presents our findings and foundation recommendations. It Is our understanding that plans for this project consist of new reinforced gunite pool to be constructed In the rear of the subject property. Final Floor elevations for the test boring's were not furnished. Major Intersections for this project are north of east of US 1, (SR 5)and north of NE 95m Street In Miami Shores,Florida,Dade County,Florida. 0000 . . 0000 0000.. STANDARD PENETRATION TEST BORINGS ... •..•.• •• •;• 0000.. • The location for the test boring's were determined by our client and&llfaupervisor . ••• and are indicated on the test boring report logs'. A review of our test samples v6overeal••• Indicate that beneath the surface the upper levels of subsoils consist of fln**C& Td sands•0 0 00:00 with some/little limestone fragments,roo4 slit and organics to a depth of+M.5 feet bebw• 0696:4 grade. Below this layer our borings discovered stratums of very loose s4V#h"ralned• 0 sands,and organic slit(muck)which continued to+/--8.5 feet below the surface. GnderVgs•;• 906960 6 these deleterious subsoils were layers of fine-grained silty sands,and limesloneNagmdnts • with little sands In a medium dense compaction condition to+/--13.0 feet BeloA thli zone4fu;•; • boring disclosed multifarious stratums ofllmestone fragments witlittie/traces of fine-medid1h • grained sands predominantly In a medium dense state of relative consolidation which extended to+/--26.5 feet below the land surface grade elevation. From this depth our boring encountered limestone fragments In a very dense to a medium dense consolidated state to -30.0 feet: These limestone substratum terminated our subsurface exploration at thirty feet maximum penetration. THRESHOLD/SPECIAL INSPECTIONS,BORINGS,DENSITY.CONCRETE,ASPHALT,ETC.A"GEOTECHNICAL TESTING LAB" i EASTCOAST TESTING &ENGINEERING, INC. 4100 North Powerline Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#9549718872 ESTABLISHED 1981 ETE u@BELLSOUTH.NET Page#2-Laboratory#7003305 1481 NE 104'h Street Miami Shores,Florida The natural ground water table was discovered to exist at an elevation of 0--3,10"- 4'10"below the existing natural-ground surface at the time of our borings. Fluctuation In the observed groundwaterlevels should be expected due to rainfall variations,seasonal climatic changes,construction activity and other on-site specific factors. The general location and nature of the proposed project,the depth and thickness of the compressible organic silt,(muck)In the upper+1-2.5-8.5 feet of depth and the existence of nearby structures preclude the use of conventional foundation methods. We therefore recommend the proposed pool and all structure's be supported on a system of helical piers, and/or pin piling. R should be noted that load bearing capacities for the proposed pool has not been given as of the date of this report HELICAL PIERS R is our professional opinion that the proposed pool, and all structure(s) be supported and designed with a deep foundation system of helical plers. Based on ourboring performed and test borings performed in the area, we estimate that a 12-14 inch helical foundation anchor installed to a minimum vertical distance of V--28 feet below the surface will provide an allowable compressive capacity of+/--30 kips,(working toads)with an ultimate bearing capacity of 60 kips,and a tension capacity of ten kips. We recommend the hellar 6 6. sections be hot dipped galvanized, (ASTM A153) and bolted, (B) and/or welded, (I)"' 0016:' connections. The shaft O.D. (inches) shall be a minimum of 3.50 inches. The shaft wall*6'• 6. gauge shall be a minimum of 0.25 Inches. The specific design of the piers shp����e left up 0000" to the speclaftcontractororstructural engineerwith respect to location,spacigg.jep and �....� load bearing capacity. Installation shall be performed in accordance with thVAQ•Channer••• Company Technical Manual Specification or equivalent 6: • ..66.6 .... ..... 1161.' 66:6 .1111. Plercapacityisdirecdydependantupon helixslzeandspacingand thej%%4=ntractor 6 �• will be able to provide the most cost effective combination of helix sizes an:f d6pV1s. Itis recommended that two,(2)test piers be performed prior to full production to determine QV•.. approximate depths and size of the helical's. Shall the design compression clapicily not be ... ;•••• achieved at the approximate depth specified additional helical plering sections will to* Installed In order to conform to the design criteria. The design of the piers should be left up to the speciality contractor and the structural engineer as required. A geotechnical engineer or his representative shall monitor the Installation of the helical piers for cert/fication purposes. THRESHOLD/SPECIAL INSPECTIONS,BORINGS,DENSITY. CONCRETE.ASPHALT.ETC.A"GEOTECHNICAL TESTING LAB" EASTCOAST TESTING & ENGINEERING, INC. 4100 North Powedine Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#954-9718872 ESTABLISHED 1981 ETE@BELLSOUTH.NET Page#3-Laboratory#7003305 1481 NE 104'Street Miami Shores,Florida PIN PILE ALTERNATIVE As an alternative to a deep helical pier foundation system, we recommend that the proposed structure's be supported utilizing a foundation system of pin piling. We anticipate that a three and one-half, (3.0"I.D.)pin pile Installed to a minimum depth of approximately +1--28 feet or to refusal conditions will yield an allowable bearing capacity of 10 kips. A minimum penetration of+1--28.0 feet below grade will be required to accept a completed pin pile and/or as determined by the engineer. Pre drilling through the surflcial fllls may be required if practical refusal Is found at a higher elevation. Pin plies driven to the recommended depth should be able to support loads up to 5 tons given the soil conditions of the site. it Is recommended that two,(2)test piers be performed prior to full production to determine the approximate depths of the pin pile's. A geotechnical engineer or his representative shall be present for the test pile operations and for the remainder of the pin pile Installation for certification purposes. We recommend that these plies have a minimum wall thickness equivalent to schedule 80. All pin piling shall be hot dipped galvanized. The sections of the piling should+•• be welded to the outer collars to insure the structural stability of the piling. Qnc a piles••• •••• • are Installed, they may be filled with 4000 psi concrete grout and attached to M6 ptopos90•••• • foundations with either embedded reinforcing,or top plates. This decision anWOR are thb* ' •••••• responsibility of the project structural engineer. �' • '• •... ...... The piling should be Installed with a Rhino Model 140 pneumatic Jack hammer, (90:"' ""'• pounds minimum weight)or approved equal,capable of advancing the piling oe required• depth,(refusal). Refusal conditions are determined with less than 0.1 inche$of mgvement see*:. In one minute of driving. •••••• Piling Installed In accordance with these recommendations will provide an allowable • compressive capacity of 10 kips. Should a geotechnical engineer from this office or his representative Inspect the Installation of the pin piling a Foundation Certitfcation will be submitted upon satisfactory completion. THRESHOLD/SPECIAL INSPECTIONS BORINGS DENSITY CONCRETE ASPHALT ETC A"GEOTECHNICAL TESTING LAB" v ' f �I EASTCOAST TESTING &ENGINEERING, INC. 4100 North Powedine Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#9549718872 ESTABLISHED 1981 ETE BELLSOUTH.NET Page#4-Laboratory#7003305 1481 NE 1040'Street Miami Shores,Florida CONSTRUCTION PLAN&SPECIFICATIONS REVIEW It is recommended that this office be provided the opportunity to make a general review of the foundation and earthwork plans and specifications prepared from the recommendations presented in this report Our report has been written in a guideline recommendation format and is not appropriate for use as a specification-type format N Is recommended that this report not be• made a part of the contract documents,however,N should be made avallabie to Qrospeetive•• •••••• contractors for information purposes. • • • 00 000.00 00 0 000000 0000.. CONSTRUCTION RELATED SERVICES •••••• 0000 0000.. 0000 0 00000 We recommend the owner retain Eastcoast Testing&Engineering 744 to perfo4h•0 •••••• construction materials testing and observations on this site. Field tests Ali Wservaflbhl 0.0 0.0 Include foundation and pavementsubgrades by performing qualityassuraric &&Ing on thh placement of compacted structural tills, and pavement courses. We can also praxid9% "•"' concrete testing, pavement section testing, structural steel testing, genera construction•• :0006 observation services,and Special inspection services. • 00 LIMITATIONS Our geotechnical exploration study has been performed,our findings obtained,and our recommendations prepared In accordance with generally accepted geotechnical engineering conclusions and practices. EastCoast Testing&Engineering,Inc.,(ETE)is not responsible foranyindependent conclusions,opinions orrecommendations made by others based on the data contained In this report. This report does not reflect any variations which may occur away from the soll borings. The discovery of anysubsurface conditions which deviates from the data obtained during this geotechnical Investigation should be reported to us for further analysis and evaluation. THRESHOLD/SPECIAL INSPECTIONS,BORINGS,DENSITY. CONCRETE:ASPHALT,ETC.A"GEOTECHNICAL TESTING LAB" EASTCOAST TESTING & ENGINEERING, INC. 4100 North Powerline Rd.-Suite G-1 4361 Okeechobee Blvd-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#9549718872 ESTABLISHED 1981 ETE@BELLSOUTH.NET Page#5-Laboratory#7003305 1481 NE 1040i Street Miami Shores,Florida The Standard Penetration Test ASTM D-1586 The Standard Penetration Test is the most commonly employed tool utilized to Identify In-situ subsurface soil conditions. The"N"values obtained from the boring provide an accurate estimation of Internal soil characteristics such as relative density,Internal shear strength,angle of Internal friction,and the approximate range of the soil's unit weight These "N"values represent the resistance of a 2-Inch diameter s hE spoon sam°jer• ": driven by a 140-pound hammer free falling 30 inches. Each drive of the 24 Triches long �k�• •• ...... spoon Is divided Into foursbr-inch increments. The second and third incre►ggaft gre totaled • to produce the "N"value found on your report. :000% .... . **:Soo . ...... .... ..... The Standard Penetration Test also allows for the recovery of sol/s=p{�qb'whiciJA0 .. • returned to our laboratory and visually examined and classified. The S,RZ jwnpies are .• available for laboratory testing If requested. Samples are generally held fob 3d days unless. ....;. otherwise directed by the client An approximate ground water table Is obtained from the borehole upon completion of the drilling procedures. This water table Is useful In the general evaluation of particular soil conditions,and maygive the contractorsome insightinto what can be anticipated during construction. it should be noted that the ground water level will fluctuate seasonally. This level may also be affected by local draw-downs, soil conditions, and the watersheds contribution to the underlying aquifer. It should not be construed to be a measure of the sol/s'permeability,or of the de-watering characteristics of the site. Although the standard penetration test Is one of the most reliable methods used to Identify soil characteristics and types,It may only represent a small fraction of the materials actually deposited at the site. As Is common Industry practice, we have assumed a uniformity of proffies between borings to provide a subsoil profile for engineering purposes. This profile is strictly based on the data obtained from the borings,and If unusual or varying conditions are found we should be notified Immediately. THRESHOLD/SPECIAL INSPECTIONS BORINGS DENSITY CONCRETE ASPHALT ETC A"GEOTECHNICAL TESTING LAB" EASTCOAST TESTING &ENGINEERING, INC. 4100 North Powedine Rd.-Suite G-1 4361 Okeechobee Blvd.-Suite A-5 Pompano Beach,Florida 33073 West Palm Beach,Florida 33409 Broward(954)972.7645(SOIL)-Dade(954)972.7645 (954).972.SOIL FACSIMILE#954-9718872 ESTABLISHED 1981 ETE@BELLSOUTH.NET Page#6-Laboratory#7003305 1481 NE 100 Street Miami Shores,Florida A test is expresslyrepresentative of the Immediate location tested,and the reliability of the conclusions Is a direct result of the quantity of tests performed. Any variation in location may reveal similarly some changes in the depth,thickness,texture,and conditions of the stratum encountered. Unless speciflcallystated otherwise,and specifically directed and prearranged by the client, all elevations are taken with respect to the existing ground surface at the time of testing. Boring locations are usually obtained In the field by pacing off distances and approximating right angles to landmarks and property comers. More precise locations may be obtained from on site surveys and placement of the boring locations by a Land Surve� g• Registered In the State of Florida. These services are provided at additionrl coets and era.• beyond the scope of this report •• • .. . The data presented herein was obtained for the specific purposes 2110toeNln this • •• • repor4 and should not be misconstrued to apply to any other circumstapttf pjojecti•Qr;• • • ancillary use unless so specilled and addressed by the engineer of record. •••• • ••e•• 90.60. 9999 .0009 Thank you for using EASTCOAST TESTING AND ENGINEERING,'IA1C., for kbt& 0000:0 geotechnical needs. Should you need further assistance with this or a f bMbr projece • please contact this office. • 6 6 6 • •••••• 9 . . .69.6. 90 0 0 009 0 • 99 Respectfully Submitted; EASTCOAST TESTING&ENGINEERING,INC. Cerfftfcate of Authorization#3425 2/15/2015 Mohammed A.Hal,R.E. Craig mith,P4 sident Senior Geotechnical Engineer Florida Registration No.59345 b1wpdocs{70A3305,iamesbroon.cscom.cs mh THRESHOLD/SPECIAL INSPECTIONS,BORINGS,DENSITY.CONCRETE.ASPHALT.ETC,A"GEOTECHNICAL TESTING LAB" 7 T •. moms& Quality,SeMc%iMtegrity,Gent to bwWlence Model:gl@7D-SM POOL 01M WR per sirr8le an psrg(and/or with tts;7n by using the second set of sensors). Care n®t be used�r wlaedo asset to eaoh o9�®r. Ev Magnetic sensor entry alarm > _"Alu%ays on"alarm pratedon 0 Adult pass-through auto reset button r > High output 110415 dB alarm P� Watedwgthe r resistant housing Magnego sensor for additional doorfsoreen door Low battary LED display 601d'1' p Addtiorml pass-through button for debyed entry tan either side door or fence 20 Ff:9,800 Pcs. > Intended for interior or axlerlor use 40 F719,080 Pos. 40 HQ.22,MS Pcs- > 9V wry operation(not Included_ UPC Barcode:01457518701 1 b", Pool Guard Alarm USA Patent Pio•5,473,310 and No.6,727,819 > ETL Approved under UL 2017 Standards I www.tachkomald.com ) Office Produc%(sem) � SM city Products(9 0)380-7300 . • •• • .. • • • 00.. .•• •• • . • •• . ••. . •.. • . ... . .• . •• • • • • • • • • • . . • •• .• • • • •• •. ••• • • • ••• • • LO s GL.Q t LO WN1 bin -00 Boo Ifib Aw IL ................... p p p I n ®P • •• •• • • • • • • • • • • b LM - • • • • its ai CR • •• • • 1 I {a• • I • f STRUCTURAL CALCULATIONS BREEN RESIDENCE 1481 N.E. 104 ST. MIAMI SHORES, FL 330138 Nw 1 W141 E OF tc • a •• ••• • • • • • •• • •• • • • • ••• • •• ••• *o: •• Fernando Morales P.E. PE#51441 . •. .••• . . •0:• . . 5201 SW 162nd Place . . .•• ; . ••; .• . •.; ; Miami,FL 33185 ..: .•' '.' •.' '.' PH:786-380-9739 . •• •• . . . •• .. ... . . . ... . . \ C.7, :. • • •• • • • r • ®ia�® f dip _._. .,«0 i • • • • • r • , C 1Q,9 'o ' Is of W 0 It • • :•• • • ... .. OF r .. �^... •fit-aI1 _ r � - s. lv a� OPC le I 'S s4 71, Ark "t • • • ^• • • • • 1 " • • ' Ymom 5A41 ID r PF L v� ��• • • • ••• 0 • r1Nr M .'Y1�: ,)� n.. .>>q 'tea ,. :.r� •.-:1fQ• ...•� to 4411 , A. 47, 46 1 i 4p 7 ym+� .. .,.. a� YT• `�• w ..•.: ,: •:. .�fiqe��yyv' � ttt.ro r rr 25-, i '.. ••• ' ••• . • _ •. ♦rs r ♦ • Ake. •• `:: PILING NOTES SEAWALL(2)#5 HOOKS 1.HELICAL PILES TO BE INSTALLED BY A LICENSED _ PILING INSTALLER — — —— —PROPERTY LME WELDED-CAP PLATE 2.REFER TO ATTACHED SOIL REPORT FOR SOIL WISLEEVE MR 3'EMBF�MENT ANALYSIS. 011wx 112"We 3.HELICAL PILES PART#AHRD-2875-=.1Y-14'T TO BE slass INSTALLED PER PLAN.PILES ARE SCREWED INTO THE GROUND AND WILL FOLLOW THE LOAD LIMITS SET FORTH FROM ATLAS-HELICAL PRODUCTS REPORT STATING THAT THIS PILE HAS A PIER COLUMN COMPRESSION LOAD LIMIT OF 100.000 LBS.,AN 2875 OD 282 WALL ULTIMATE TENSION STRENGTH OF 100.000 LBS.AND ®'15 TON HELICAL PILE H.D.G.(Hot D W A USEABLE TORSIONAL STRENGTH OF 7.500 FT. -LB. Gahan md) 4.PILING PLACEMENT AND QUANTITY SHOULD BE REVIEWED BY GEOTECHNICAL ENGINEER AND PILING • CONNECTOR CONTRACTOR PRIOR TO INSTALLATION. • �3' for, 3'� • CONNECTION BOLTS - f ----- Af 4-GRADE 8 H.D.G. r-r 314•DhL H�999 8-3' • • �••• 000000 14'DhL •• • i9•• • 0I • • • 0000•• q• • •0900• • HELIX PLATES1:0 ••0.0• 15 TONS DESIGN LOAD •••••� • •90 •0*0•• 30 TONS ULTIMATE LOAD 0000•• I 00000000 12'DIE8 3' • • I• •• • � � i •9 •• I •• • 0000•• TOP ROW OF#4AT8' �99v9� I • •• i O.C.EACH WAY • • i • • •0.9 0• 1 .09090 I I I BOTTOM ROW OF#4 AT • • • I :00000 TYPICAL NEW CO CROSS-SECTION DM PIER A 11 8'O.C.EACH WAY •• • • ••• • • HELICAL NEW CONSTRUCTION PIER - —I_ T -t— t 7.8' i "8 ROWS TO BE OFFSET s 1 "I -I HCi20NTALLY FROM EACH OTHER AND A MAXIMUM OF 8'VERTICALLY POOLBEAM ('-------------� I I FLOOR STEEL DETAIL I I I 1 TOP VIEW I I I POOL FLOOR 44 8.O.C. N.T.S. I I I I FACT WAY 1 1 I I eL_ IN WALLS I j I (2)MATS OF#4@iroC. I EACH WAY 14'0 HELICAL FILE I ��sui, EQUIP. I 1 I ;5< r 8PA) I I WELDED STEEL (5)#5 30'LONG @ I I PILE CA' 8'O.C.EACH WAY 3Wx30'MAT OVER TOP I L-------------------------J I OF EACH PILING TO BE I I I (5)95 REBAR AT I.O.C. I I EACH WAY AHRD 2.875-282 42"-141 MAT OVER EACH PILING I I TOP VIEW 1 HELICAL PILES ATTACHING N.T.S. • TO POOL FLOOR DETAIL I i N.T.S. l v SEAWALL - PROPERTY LINE L - - - - - SPECIFICATIONS POOL SIZE: 15x30' POOL DEPTH: 3'x5' SCALE: PERIMETER: — w VOLUME(GALLONSk 1 12950 1/8" = 1' TURNOVER RATE: 6 HRS SURFACE AREA S4 FT.: 450 12'-10" POOL EQUIPMENT 18'-10" POOL PUMP#1 TYPE I JANDY WALL INLETS: 3 POOL PUMP#1 SIZE:I 1-112HP 2-S-P-D-1 LED POOL LIGHT: 2 10' PAVER h� POOL FILTER#1 TYPE:L200 S.FT. SALT GENERATOR: YES SKIMMER-.1 1 SUCTION UNE WNAC LOCK: YES DECK 6' FINISH ITEMS 12-6" BENCH ------------------ COPING: 6X12 TRAY DECK TYPE: PAVER I TILE:L it 7 DECK SQ•FT. 4611 1 GEM FINISH: V.K.SUPER BENCH-1 YES 3 I I BLUE U II STING SPECIAL NOTES CONI CRETE I PILING POOL: NO POOL ENCLOSURE: WALL J PAD TO ELECTRIC: BY OTHERS F- REMAIN LU I I Z 30' I I I i I I ---J THE POOL SHALL BE LOCATED IN A MANOR THAT COMPLIES F - WITH N.E.C.680.8 FOR OVERHEAD CONDUCTORS AND N.E.C. •••••• 1 680.10 FOR ALL UNDERGROUND CONDUCTORS. ; ••• •••• ••• • L-- ------------------ .. .. . r PER FBC-RESIDENTIAL R4101.17: '•';" •• ••• • 1 ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESSVIM •• THE HOME TO THE POOL SHALL BE EQUIPPED WITH a APEX14T• • • • • 3 4' I I I ALARM COMPLYING WITH UL 2017. •••• :•�••• ••• 2'-10" r------_---- FENCESANDGATESWILLMEETFBC2010R4101.17.1•• •• .•.. •.• • THROUGH R4101.17.1.9; EXISTING GATES W/SELF-C4i)6iN*^i,9 SELF-LATCHING DEVICE LOCATED MIN.54"ABOVE GItADL. : • • ••• • '$, I ALL GATES SURROUNDING THE POOL AREA WILL SVgW •••••• -15' ' 4 I OUTWARD AWAY FROM POOL. • ••• • :.. I I 12'-10" I .� �• .•e„1:Fvvi •. � '. 1 I I RESIDENCE �' ' o REVISION 08111/15:REVISED DECK TO HOLD 10'TO SIDE PROPERTY LINE EXISTING j j F.F.E.+7,75' _ VT,: REVISION 06130115:MOVED POOL TO HOLD 12.5'TO SIDE PROPERTY LINE FROM POOL WATERLINE I CONCRETE I1 6'CBSWALL PAD II to-Z DATE: 05/07/15 SHEET 1: SPECIFICATIONS AND LAYOUT '.• �t_OitOp;•• � `moo Eif,^ •••....••• ` VAN KIRK AND SONS L————EQUIP. ��Ps1 11 to A�- > DEERFIEW BEAC3144 S.W.13th H,FL W442 &P� 1 1 I `' '' 954-751-"" BREEN RESIDENCE I 1481 N.E. 104 STREET I L------------- -----------J j MIAMI SHORES, FLORIDA 33138 I I I Fernando Morales,P.E. soot S.W.182 Phwe LEGAL DESCRIPTION 6'CBS WALL I Mama,FWft 3185 LOTS 10&11,BLOCK 3 U�785,38"73D 1 RIVER BAY PARKADDN PLAT BOOK 40,PAGE 72 JOB#57030 ' SEAWALL - - - - - - — - - PROPERTY LINE - - --�- �",o '-- - - - - - - SPECIFICATIONS Q POOL SIZE 15x30' POOL DEPTH: Y x 5 ��aR�` Qto� SCALE: PERIMETER: w VOLUME(GALLONS): 12950 �ea\t S•&$e\\ TURNOVER RATE: 6 HRS SURFACE AREA SO.FT.: 4W 1r-10° `v00raag.�� POOL EQUIPMENT O �o•• A�Q\\ LOA h POOL.PUMP#1 TYPE: DANDY WALL INLETS: 3 POOL.PUMP#1 SIZE: 1-U2HP 2SPD LED POOL LIGHT: 2 5, Qate�a`��8 yERMIT FILTER#1 TYPE: X0 SQ.FT. SALT GENERATOR:r YES PAVER s\� _ o I d SKIMMER 1 SUCTION LINE WNAC LOCK: YES DECK �' MIAMI SHORES VILLAGE FINISH ITEMS g - COPING: 8X12 TRAV IDECK TYPE PAVER BENCH i DROVED BY DATE TILE:j DECK SQ.FT. 4611 GEM FINISH: VX SUPER BENCH:j YES BLUE 3 ZONING eo SPECIAL NOTES v J EXISTING ZD EXISTING I PILING POOL: NO POOL ENCLOSURE WALL I CONCRETE STRUCTt�RAL J PAD TO I ELECTRIC: BY OTHERS F- REMAIN LU Z30� , ELECrItICAL POOL SHALL BE LOCATED IN A ar F ------ i ---J OR THAT COMPLIES WITH N.E.C.680.8 3' I PLUMBING OR OVERHEAD CONDUCTORS AND N.E.C. �- L---r--- - - -1/ -- ` 10 FOR ALL UNDERGROUND ONDUCTORS. I I MECHANICAL PER FBC-RESIDENTIAL R4101.17: { ALL DOORS AND WINDOWS PROVIDING 3' 4' I ! DIRECT ACCESS FROM THE HOME TO THE - J POOL SHALL BE EQUIPPED WITH AN EXIT 2'-10" r--- --- ---J I ALARM COMPLYING WITH UL 2017. MOD I ! FENCES AND GATES WILL MEET FBC 2010 R4101.17.1 THROUGH R41 4' 15' 4' I SUBJECT TO COALLMPLWNCE WITH qFEDERAL ' EXISTING GATES W/SELF •TATE AND CO R SELF-LATCHING DEVICE A" MIN.54" +��V ;� L ULAlnT0t.3 f ABOVE GRADE. ALL GA Ftpp` ' SURROUNDING THE POO AREA Wlat t 16-4 I i RESIDENCE ♦�� '�XCENsF'•.�1�,'� SWING OUTWARD AWAY EXISTING I j I F.F.E.+7.75 N , 1 I _ 4 - I CONCRETE 6'CBS WALL I PAD I TE OF � DATE: 05/07/15 SHEET is SPE IFW*4TjQrJS•ASID.4Y9lJT i�� ••• '• �� VAN KIRK AND SONS • • •• • • • • • �it, ORION z' • •• • • • • •.• • I I L——— I ( i� •• .• 3144 S.W.13th DRIVE • • 0.: • • • • • I MEQUIP. — •rFS ••••••• � ♦• DEERFIELD BEACH.FL 33442GREEN RE •• •••SPA �S/ONA; ♦� 954-7554402 I &E&W3 -------------- ------------� I V�� Mra3Z38' 'Fernando M P.E. LEGAL DESLON • • • • e,CBs WALL :BY - N 2 6 2015MOM,FlorWa ,85 LOTS 10 S 1RIVER BAY .•. . . . • ..• . • LIcmm'*1441 PLAT BOOK 40,PAGE 72 ; • #67030 SCALE FLAT GRATE OR ANTI-VORTEX MAIN DRAIN COVER INLETS TESTED TO ASME Al 12.19.SM 2007 BY UL 8172 POOL LISTED WITH ANTI-ENTRAPMENT COVER CHANINEL 1-10 DRA TYP. 32• 7r 2, -------- MIN. BENCH BENCH 0 VACUUM SKIMMER 2 WAY SALT GENERATOR HYDROSTATIC BEING UUG SED T VALVE REUEF VALVET 2• 2■ TYP 3 I ILSUCTION TO PUMP 5 3 WAY I CHANNEL DRAIN DETAIL HAIR�`LINT VTYP FILTER AIR RELIEF b I STRAINER PRESSURE GAUGE i I ALL CHANNEL DRAINS ARE VGB 2008 COMPLIANT 11 BALL VALVE F THERE ARE THREE AVAILABLE PORTS ON THE CHANNEL DRAIN. PUMP TO ON SITE z I ANY ONE OR MORE PORT CAN BE USED FOR THE SUCTION TO WASTE WELL I EXISTING THE PUMP. ANY ONE PORT CAN BE USED FOR A HYDROSTATIC J I CONCRETE RELIEF VALVE. ANY UNUSED PORT CAN BE PLUGGED OR,INA PLUMBING SCHEMATIC PAD TO SPA,CAN BE USED AS A RETURN PORT. REMAIN ALL PIPING SHALL CONFORM TO i a FBC-RESIDENTIAL R4101.6 .� i I PER FBC 403.9.4 RESIDENTIAL POOL PUMPS AND PUMP MOTOR6\� 1. POOL FILTER PUMP MOTORS SHALL NOT BE SPLIT-P SHADED-POLE,OR CAPACITOR START4N CTION RUN TYPES. Ff———————— 2. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HP>_1hp I I SHALL HAVE THE CAPABILITY OF OPERATION AT-TWO�OR,MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF I I NO MORE THAN 112 OF THE MOTOR'S MAXIMUM ROTATION RATE. II I- VAC UNE ---- 2-------� I j 2-t/2'INLETS I I I G P �s PIPE SIZE MAX. FLOW �DRAINSIMMER I i RESIDENCE Approved INCHES 6.0 ftisec 8.0 ft/sec I I F.F.E.+7.76 Disapproved 1-r 38 m E I XISTING CONCRETE PAD I I 2" 63apm 88 4 gprn TO BE SAWCUT AND I I 2-10 90 gpm 119 6,CBS WALL I I REPLACED AS NEEDED ( ( 3° 138 184 FOR NEW PIPES I I 4" 238 m 317 I tUlir// I I I I I ����� ODO A.4'Ip i ———— I I ��� ��,.,....... 'Qq PER ANSI-7:THE MINIMUM SIZE FOR THE SUCTION SIDE i' `{'c: EQUIP. I ti� F� �CENS &PAD I I I ��• F Fi/► FILTRATION AND AUXIUARY BRANCH PIPING IS 6 FPS;THE e::i.it I I S MINIMUM SIZE FOR THE SUCTION SIDE FILTRATION AND N •I = AUXILIARY TRUNK PIPING IS 8 FPS;THE MINIMUM SIZE FOR THE RETURN SIDE FILTRATION PIPING IS 8 FPS;AND THE L------------- ------- L�/, � MINIMUM SIZE FOR THE AUXILIARY RETURN LINE IS 10 FPS. I ATE 6 ''tee O.c.-•• to .•••��'��. SHEET 2: PLUMBING... . . . . . .. F � � //l AL 3144W 13th DRIVVAN IORK AND E �• •i •�i i i i•i �• • • • • • • • • DEERFIELD BEACH,FL 33442 •• ••• •• • • • •• 934-755-4402 BREEN RESIDENCE 1481 N.E. 1ASTEET.0. 000 MIAMI SHORES,FLORIDA 33LM Fernando Moralm,P.E. • •• • • • • • • slot s.w.,st pace LEGAL DESCRIPTION ••• • •• • •• • MWd. 33IN LOTS 10$11,BLOCK 3 Ucense#5 441 1 RIVER BAY PARK ADDN ... . . . . ... . . PLAT BOOK 40,PAGE 72 ; ; ; ; 40B#.57030 ••• • 0 0 000 0 0 PER NEC 200$680.22(B)GFCI PROTECTION.OUTLETS SUPPLYING POOL PUMP JUNCTION BOX ADJUSTABLE MOTORS FROM BRANCH CIRCUITS WITH SHORT-CIRCUIT AND GROUND-FAULT PRE_CAST z COLLAR WEIR PROTECTION RATED 15 OR 20 AMPERES,125 VOLT OR 240 VOLT,SINGLE PHASE, COPING Z WHETHER BY RECEPTACLE OR DIRECT CONNECTION,SHALL BE PROVIDED WITH " GROUND-FAULT GRCUIT4NTERRUPTER PROTECTION FOR PERSONNEL 5—0 MIN. water Ine PUMP 1-2P-20A GFCI I i 4#10 THHN IN LIGHT 1-IP-15A L�---�J 13"TO 1fY CONDUIT AUTOMATIC CONTROL 18" MIN.: ,r= 1"PVC -' 13"TO 200A METER MAIN COMBO i TOP OF FIXTURE 7 PERFORATED ' z00A 0 GFI TO BE MIN.S' 8 Max BASKET 1 0 PANEL 20'FROM WATER'S EDGE TRANSFORMER STAINLESS STEEL LIGHT NICHE 2"TREAD 1-2P-200A 1-2P-WA � (12 VOLT)TO COMPLY WITH JUNCTION BOX(TYP) S.F.B.C.AND NEC SW (SEE PLAN FOR LOCATION) 80w LED POOL LIGHT SKIMMER DETAIL 60wLED POOL LIGHT SECTION UNDER WATER LAMP N.T.S. NOTE 1.5 hp 2 Bpd PUMP THE POOL SHALL BE GROUNDED PER Where provided,the vacuum OI'pressure leaner mdtig(s)shall be located in an FROM TRANSFORMER TO JUNCTION BOX: THE NEC 680.25 REQUIREMENTS ALONG 300W.2#10 THHN+1#12 THHN 4#12 THHN IN 112°COND. WITH THE OTHER APPLICABLE CODES accessible posftn(s)at least 6 inches and not greater than 12 inches below the 150W:3#12 THHN THAT ARE NOTED ABOVE. minimum operating water level oras an attachment to the sklmmer(s). 75W OR 100W:2#14 THHN+1#12 THHN 3#12 THHN IN 112"COND.FOR PER NEC 430.32-POOL MOTORS HAVE EW ALL 1/2'CONDUITOR 25W LED:3#12 THHN CHLORINE GENERATOR OVERLOAD PROTECTION(SEE /0 j'¢�Y!� ALL MANUFACTURER'S SPECS FOR APPRO ®ATE VERIFICATION} POOL ELECTRICAL DIAGRAM EQUIPOTENTIAL BONDING GRID: 7 PER F.B.C.AMENDMENTS SECTION 10423 ALTERNATIVE MATERIALS AND METHODS FOR ALL ELECTRICAL WORK SHALL SWIMMING POOL AND SPAS WITH THE INSTALLATION OF 15-VOLT OR LESS SWIMMING POOL CONSTRUCTION NOTES: LIGHTS OR NO LIGHT,PERIMETER SURFACES AND EQUIPOTENTIAL BONDING GRID(SINGLE CONFORM TO N.E.C.ARTICLE#680 WIRE). PERIMETER SURFACES AND EQUIPOTENTIAL BONDING GRID(SINGLE WIRE)INCLUDES UNPAVED SURFACES AS WELL AS POURED CONCRETE AND OTHER TYPES OF PAVING. 1. ALL CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH FBC-RESIDENTIAL 2010 BONDING FOR PERIMETER SURFACES SHALL BE INSTALLED AS FOLLOWS: CHAPTER 41. 1. ATTACHED TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID(SINGLE WIRE)AND 2. REFER TO THE SOIL REPORTY PREPARED BY EASTCOAST ENGINEERING AND TESTING DATED 2. BURIED TO A MINIMUM DEPTH OF(4)FOUR INCHES TO(S)SDC INCHES BELOW GRADE FEBRUARY 15,2015 FOR SOIL ANALYSIS. AND 3. SWIMMING POOL TO HAVE PNEUMATICALLY PLACED CONCRETE FLOOR,WALL AND BOND BEAM. 3. MINIMUM OF(4)FOUR POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE POOL(EXCEPT FOR NONCONDUCTIVE POOL SHELLS,BONDING AT FOUR POINTS SHALL CONCRETE TO HAVE 28 DAY COMPRESSIVE STRENGTH OF 3,000 P.S.I. NOT BE RQUIRED)AND 4. ALL REINFORCED STEEL TO BE INTERIM GRADE DEFORMED BARS OF NEW BILLET STEEL: CONFORMING 4. CONNECTED TO AN EQUIPOTENTIAL BONDING GRID(SINGLE WIRE)WITHE A SOLID TO ASTM A-615. STEEL TO BE BENT,LAPPED AND PLACED IN ACCORDANCE WITH A.C.I.STANDARDS COPPER BARE CONDUCTOR NOT SMALLER THAN#8 AWG AND AND SPECS. 5. CONNECTION SHALL BE MADE EXOTHERMIC WELDING OR BY LISTED PRESSURE CONNECTORS OR CLAMPS THAT ARE LABELED AS BEING SUITABLE FOR THE PURPOSE 5. IN AREA OF SKIMMER,2-#3 BARS IN BOND BEAM MAY BE PLACED EITHER BELOW OR BEHIND SKIMMER. AND ARE OF STAINLESS STEEL,BRASS COPPER OR COPPER ALLOY AND 6. ALL PIPING SHALL BE N.S.F.APPROVED AND SHALL BE SCHEDULE 40 PVC. �,,`% ,�,�11t011lt 1 ttte��J S. THE EQUIPOTENTIAL BONDING GRID(SINGLE WIRE)SHALL EXTEND UNDER PAVED ODO A.MD WALKING SURFACES FOR MINIMUM 18°AND MAXIMUM 24°HORIZONTALLY BEYOND THE 8. WATER 7. MAIN DRAIN OHAVE A FREE Y AND DISPOSAL AREA TO BE4TIMES THE ARRANGEDSOUTH TOF THE SUCTION LINE. THERE S NO CROSS-CONNECTION WITH A `�.`���c�,��,�DEN3F'R��E`�'% INSIDE WALLS OF THE POOL AS ALLOWED UNDER EXISTING CONDRIONS DOMESTIC WATER SUPPLY. 41 9. IF REQUIRED,UNSCREENED POOLS SHALL HAVE A MINIMUM 4 FT.FENCE WITH SELF-CLOSING AND LATCHING GATE. _ i!�'� SHEET 3: NOTES �1F AV�CTRIP �• 10. ALL METALLIC POOL FITTINGS WITHIN 5 FEET OF THE INSIDE WALL AND THE DECK REINFORCING SHALL SAT OF 4 6" �• : • BE BONDED TO THE POOL REINFORCING STEEL WITH A NO.8 AWG COPPER WIRE. THE POOL 'A t� VAN KIRK AND Servs • ��i��,p�••.FCORIDP;.•• `c1�`��'' 31443.W.13tl1DRIVE •.� •.i •.i �.� i i •�• REINFORCING STEEL SHALL BE BONDED TO THE POOL LIGHT NICHE WITH NO.8 AWG COPPER WIRE. �� F . DEEI2FlELD BEACH,FL 33442 TWO NO.8 AWG COPPER GROUND WIRES SHALL BE RUN WITH N.E.C.APPROVED CONDUIT,ONE sS/ANAL � 1%4-765-4402BREEN RESIDENCE INTERNALLY,FROM THE LIGHT NICHE TO THE JUNCTION BOX. COMPLETION OF THE POOL GROUNDING "NtttI � 1481 N.E. t"9FREET• ••• • SYSTEM TO THE PANEL BOARD BY ELECTRICIAN. MIAMI SHORES B-O&D64 3313$•• 11. POOL CONSTRUCTION SHALL BEAR ON CLEAN SANDS OR ROCK WITH A BEARING CAPACITY 2,000 P.S.F. Fernando Morelos,P.E. • •• • • • • • 5201 S.W.162 Pleas LEGAL DESCRIPTION •.• • •• • •• • 12. FBC-RESIDENTIAL 2010 CHAPTER 41 SECTION R4101.6.1 CONFORMANCE STANDARD:DESIGN, Mme,P"W 33185 LOTS 10 811,BLOCK 3 CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF 785480.9739 RIVER BAY PARK ADDN ANSIMSPI 3,ANSIINSPI 4,ANSIMSPI 5,ANSIMSPI 6 AND ANSIMSPI 7. License#61441 PLAT BOOK 40,PAGE 72 • % : •: dOS*7030 . ... ... . . 0 ... . . WATER LINE WITH 0 ONE ROW of TILE MIN. MIN. WATER LEVEL SECTION THRu CL SLOPE 3' % EfE —BEAM 21" 18" 21 UNDERWATER BENCHES,SWIMOUTS 5 1'r— AND SUNSHELVES TO BE VISUALLY SO WALLMALSET APART FROM POOL FINISH WITH A TILE EDGE OF A CONTRASTING COLOR. MAIN DRAIN 11° MAX TYP BENCH SECTION N.T.S. 21'4r 3'-6" 18" 3'-6" 25 30' TYPICAL SECTION FOR TYPE O POOL EQUIPMENT PAD DETAILS (DIVING EQUIPMENT PROHIBITED) ° N.T.S. ° , 4"CONCRETE PAD PER F.B.C.1820.3 FILTER BASE IM PER ANSM-2003 6.22: BASE ALL RISERS AT THE CENTERLINE SHALL ° ° PUMP HAVE A MAX.UNIFORM HEIGHT OF 12', EXCEPT THE TOP OR BOTTOM RISER, WHICH MAY VARY IN HEIGHT,BUT SHALL NOT EXCEED 1r. TOP VIEW SIDE VIEW MIN.240 SHIN. SURFACE AREA ALL ANCHOR BOLTS THROUGH BASE TO BE 3/8"LAG BOLTS ON TOP STEP OR TAP CONS FOR ALL EQUIPMENT. SEE MANUFACTURER'S SPECIFICATIONS FOR ANY ADDITIONAL DETAILS AND DO A 4f,, ANCHORING POINTS. DETAIL IS COMPLIANT WITH FBC 301.12 pNA.tij '�J�i O,Q9'% INSUANT WIpTH FBC�1620 PERTAINING TO WIND LOF EQUIPMENT WILL BE OADS. 1r MML = No 4 T = ' YP• ATE ��Q"'�` y p �¢ SHEET 4: DETAIL,•Ajjp •S�OPE • •• 1' 1' I.-W s�Ox\' ��ORI�JA,. '��� VANKIRKA/Y[)SONS • • •• • • • • i i •......• • •• • • • • ••• • MIN.240 SHIN. ��j�S`p� DC7 3144 S.W.13th DRIVE • • • • • • • • • SURFACE AREA ��i �1VAL f- DEERFIELD BEACH,FL 33442 •• ••• " • • ` •• ON TOP STEP '''fl«It,t:��ti`'`� 964-74402 BREEN RESIDENCE 1489 N.E. 181 SfREET•• ••� .'. .'• MIAMI SHORES„F.L0FlQ,4 SJ13p• ••; ; CENTERLINE OF STEPS I 1 10• Fernando Maalm P.E. •• • . . . . N.T.S. r 82x1 S.W.182 Paw LEGAL DESCRIPTION `•• • •• • •• • Mtend.Fbrtde33188 LOTS 10$11,BLOCK 3 78S-380-9M 1 RIVER BAY PARK ADDNLicerme ... . . . . ... . PLAT BOOK 40,PAGE 72 • ;OB tt57030 PILING NOTES., (2)#5 HOOKS 1. HELICAL PILES TO BE INSTALLED BY A LICENSED ' PILING INSTALLER. =15 TON HELICAL PILE WELDED-CAP PLATE -"- 2. REFER TO ATTACHED SOIL REPORT FOR SOIL W/SLEEVE MIN.3 MBEDMENT ANALYSIS. 6"x 8"x 1/2° 3. HELICAL PILES PART#AHRD-2875.262-12'-14"-7"TO BE other sizes avatlaile INSTALLED PER PLAN. PILES ARE SCREWED INTO THE GROUND AND WILL FOLLOW THE LOAD LIMITS T W T SET FORTH FROM ATLAS-HELICAL PRODUCTS ~——— REPORT STATING THAT THIS PILE HAS A r PIER COLUMN COMPRESSION LOAD LIMIT OF 100,000 LBS.,AN 2'-6' ULTIMATE TENSION STRENGTH OF 100,000 LBS.AND I 2875 OD.262 WALL A USEABLE TORSIONAL STRENGTH OF 7,500 FT.-LB. H.D.G.(Hot Dipped 4. PILING PLACEMENT AND QUANTITY SHOULD BE Galvanized) REVIEWED BY GEOTECHNICAL ENGINEER AND PILING • CONNECTOR CONTRACTOR PRIOR TO INSTALLATION. ® { • I • I XY CONNECTION BOLTS I EXISTING 4-GRADE 8 H.D.G. i 6'-3" J CONCRETE PAD TO 3/4"Dia. I— I REMAIN TOP ROW OF#4 AT W Z x xI { { I O.C.EACH WAY =� 00 14"Dia. r { { BOTTOM ROW OF#4 AT � 6 I { W O.C.EACH WAY Oxy- I I ROWS TO BE OFFSET 5" _ .•. •••• •• ;• HELIX PLATES HORIZONTALLY FROM EACH OTHER 6-3° {•• • ••• AND A MAXIMUM OF 6"VERTICALLY 1 • •• •• •• 15 TONS DESIGN LOAD • 30 TONS ULTIMATE LOAD4 ————————— " q...---s--ir —'w .� 12°Dia. FLOOR STEEL DETAIL 2'-6' ,I...' TOP VIEW '� �•••• •••• •• •� N.T.S. .I'..' ..:. .. .. 15-10" • • • r ——————� 'I I .'. RESIDENCE 6" I TYPICAL CROSS-SECTION DETAIL OFA HELICAL NEW CONSTRUCTION PIER00 POOL BEAM I I I I { I I I II I I it POOL FLOOR #4 @ 8"O.C. I " I I i EACH WAY { I .•; IN WALLS �,gaelmlllaS�rsaaL.I~ EQUIP. I I &PAD I I I o ; 14"0 HELICAL PILE � (2)MATS OF#4 @ 8"O.C. � � f °- '�=� •=`• REVISION 06/30/15:MOVED POOL TO HOLD 12.5'TO SIDE PROPERTY UNE FROM EACH WAYl ;�,, POOL WATERLINE ?� a SHEET 5: PILING DETAILS 30"x 30"MAT OVER TOP (5)#5 30"LONG @ OF EACH PILING TO BE WELDED STEEL . -"a VAN KIRKAND SONS PILE CAP 6°O.C.EACH WAY r`ti (5)#5 REBAR AT 6°O.C. d; 3144 S.W.13th DRIVE EACH WAY DEERFIELD BEACH,FL 33442 MAT OVER EACH PILING { ►-� BREEN RESIDENCE ''r 1481 N.E. 104 STREET TOP VIEW I .. •, . .: ,5:v .. AHRD 2.875-.262-12"-14" MIAMI SHORES, FLORIDA 33138 N.T.S. Fernando Morales,P.E. LEGAL DESCRIPTION HELICAL PILES ATTACHING M ' 33185 LOTS 10&1 BLOCK 3 TO POOL FLOOR DETAIL 79M RIVER BAY PARK ADDN N.T.S. License#61441 PLAT BOOK 40,PAGE 72 JOB#57030 (2)#5 HOOKS 1. HELICAL PILES TO BE INSTALLED BY A LICENSED PILING INSTALLER. ® =15 TON HELICAL PILE WELDED-CAP PLATE 2. REFER TO ATTACHED SOIL REPORT FOR SOIL W/SL.EEVE MIN.EMBEDMENT LYSIS. sox 8"x 1/2" 3. HELICAL PILES PART#AHRD-2875.282-120-14"-7°TO BE other sizes available INSTALLED PER PLAN. PILES ARE SCREWED INTO THE GROUND AND WILL FOLLOW THE LOAD LIMITS 3' W 3' SET FORTH FROM ATLAS-HELICAL PRODUCTS — REPORT STATING THAT THIS PILE HAS A PIER COLUMN COMPRESSION LOAD LIMIT OF 100,000 LBS.,AN 2'-6" I ULTIMATE TENSION STRENGTH OF 100,000 LBS.AND 2875 OD.262 WALL A USEABLE TORSIONAL STRENGTH OF 7,500 FT.-LB. H.D.G.(Hot Dipped I 4. PILING PLACEMENT AND QUANTITY SHOULD BE Galvanized) REVIEWED BY GEOTECHNICAL ENGINEER AND PILING V-3" I • CONNECTOR CONTRACTOR PRIOR TO INSTALLATION. • A x0 • XY CONNECTION BOLTS I EXISTING 4-GRADE 8 H.D.G. i i 6'-3° J CONCRETE PAD TO 3/4°Dia. TOP ROW OF#4 AT 8" z :. I REMAIN I I I O.C.EACH WAY 3 XY ILi 140 Die. I I I BOTTOM ROW OF#4 AT - 1 8"O.C.EACH WAY HEUX PLATES ROWS TO BE OFFSET 5° 1 HORIZONTALLY FROM EACH OTHER 6=3" 1 15 TONS DESIGN LOAD AND A MAXIMUM OF 60 VERTICALLY 30 TONS ULTIMATE LOAD —— ——————— 4" ------ 12"Die. FLOOR STEEL DETAIL 2'-6° r TOP VIEW '�— I N.T.S. r-------------� II 6 I I l i RESIDENCE TYPICAL CROSS-SECTION DETAIL OF A I I HELICAL NEW CONSTRUCTION PIER I I I F.F.E.+7.75 POOLBEAM it I II I j II II POOL FLOOR #4 8"O.C. I \ p 9ORgf,�' EACH WAY I ``�� ��O CFN ,•;:<` ..... EQUIP. I 1N WALLS ��� =P NSE .,1 4 :L.''`.' 1 I &PAD I 14°0 HELICAL PILE ' — (2)MATS OF#4 @ 8"O.C. o N tel;l �_ II EACH WAY _ -----------------------i 1 30"x 30"MAT OVER TOP WELDED STEEL (5)#5 30"LONG @ ( pP.:�. 2: SHEET 5: PILING .DFZWLS. • . ,• OF EACH PILING TO BE 6"O.C.EACH WAY ��'s'� FLORA, • ��`�� • • 1eJRK AND SONS (5) EACHWAY O.C. PILE CAP '���si��FSS 10�P� `` p�RFW DBEADR Fl 33442 ••' •.i 00: '•• s•i ••' MAT OVER EACH PILING i 1j11111m" 954-755.44M BREEN RESIDENCE TOP VIEW I 9489 N.E. � '.3T EI;o. ••: .'. .'. N.T.S. AHRD 2.875- 262-12"-14" MIAMI SHORES J%0J?/DA 33138' • `•: : Fernando Morales,P.E. ••i i' ••' '•' 000 ••• HELICAL PILES ATTACHING 5201 S.W.162 Pboe LEGAL DESCRIPTION FWft 33185 LOTS 10&11,BLOCK 3 TO POOL FLOOR DETAIL 755-390.9738 RIVER BAY PARK ADDN ... . . . 90* 0 Lbwm#51441 N.T.S. PLAT BOOK 40,PAGE 72 ; o JOB#;57030 PER FBC-RESIDENTIAL R4101.17: THE POOL SHALL BE LOCATED IN A — — — — — — — — — — — — ALL DOORS AND WINDOWS MANOR THAT COMPLIES WITH N.E.C. SEAWALL ON PROPERTY LINE PROVIDING DIRECT ACCESS FROM 680.8 FOR OVERHEAD CONDUCTORS THE HOME TO THE POOL SHALL BE AND N.E.C.680.10 FOR ALL 12'-10" EQUIPPED WITH AN EXIT ALARM UNDERGROUND CONDUCTORS. 1g_10COMPLYING WITH UL 2017. 10' 118'-6" THE POOL SHALL BE LOCATED IN A MANOR THAT COMPLIES WITH N.E.C. 12''6" 680.8 FOR OVERHEAD CONDUCTORS 122'-6" AND N.E.C.680.10 FOR ALL UNDERGROUND CONDUCTORS. EXISTING I CONCRETE PAD TO REMAIN I I� f� TWO STORY EXISTING RESIDENCE THE EXISTING FENCES MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SECTION CONCRETE PAD F.F.E.=6.51' � 424.2.17.1 AS FOLLOWS: i 424.2.17.1.1: THE EXISTING FENCE IS LOCATED ON THE PERIMETER OF THE POOL IN THE YARD S CBS W I AREA ON THE SAME PROPERTY, IRON GATE 424.2.17.1.1: TOP OF FENCE IS A MIN.OF 48"ABOVE GRADE MEASURED ON SIDE OF THE W/SELF-CLOSING EQUIP. BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL; SELF-LATCHING &PAD 200 AMP METER 4,CBS WALL 424.2.17.1.1: THERE IS A MAXIMUM 2"CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE MECHANISMS FENCE; LOCATED A MIN. r---------------- 424.2.17.1.2: THERE ARE NO GAPS,OPENINGS,INDENTATIONS THAT ALLOW A CHILD TO CLIMB OF 54"ABOVE I i i / OVER,UNDER OR SQUEEZE THROUGH; GRADE 424.17.1.4: THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS I,E6W6�N I i / ON GATES �/ I 45";THE HORIZONTAL MEMBERS ARE ON THE POOL SIDE OF THE-FENCG;THE SP •••• • ./i W/SEL=-CLOSINPs, � DRAIN FIELD i— � ' BETWEEN THE VERTICAL MEMBERS DOES NOT EXCEED 1-314"; SELF-LATCHING 424.17.1.5: THE DISTANCE BETWEEN THE TOPS OF THE HORIZONT • S IS 46"2 MORE; i / �__� — MECHANISMS THE SPACING BETWEEN THE VERTICAL MEMBERS DOES NOT EX •• • •••• • / SEPTIC LOCATED A MIN. IN ADDITION,THE FENCE GATE(S)MEET THE REQUIREMENTS OF THE"(MOA BUILDING"CODE • • TANK OF 54"ABOVE SECTION 424.2.17.1.8: •••• • s i •• GRADE I EXISTING GATE(S)ARE SELF-CLOSING AND HAVE A SELF-LATCHING tQGI ll;DEVI*?WCA'1'ED •••• ' --------------�-� I ON THE POOL SIDE OF THE GATE(S); • • THE MECHANISM IS PLACED SO THAT IT CANNOT BE REACHED BYAY01J &HILD OVIV ME / I TOP OR THROUGH ANY OPENINGS OR GAPS FROM THE OUTSIDE / + THE GATE(S)SWING OUTWARD AWAY FROM THE POOL; •••••• • • / DRIVEWAYGATES)AND BARRIERS HAVE NO OPENINGS GREATER THAN 10 41/111181 OF THE* •••• • I MECHANISM; • • • • THE DEVICE RELEASE MECHANISM IS LOCATED NO LESS THAN 54"FfWTIJE BOTTOMQF THE • • • /GI I GATE AND IS NOT LOCATED ON POOL SIDE OF GATE. go • • / REVISION 08/11/15:REVISED DECK TO HOLD 10'TO SIDE PROPERTY UNE / I _ `mllllllllrr REVISION 06/30/15:MOVED POOL TO HOLD 12.5'TO SIDE PROPERTY LINE FROM 150.00'PROPERTY UNE ' fi< CR q !y POOL WATERLINE ' r r' �`J' SHEET 6: SITE PLAN 12'PARKWAY Y j j r.I VAN KIRK AND SONS 3144 S.W.13Bh DRIVE - - - - - - - - - - - - - - - - - - - - - — 'u' ' �\\1'�� � _ DEERFIELD B EACH,FL 33442 5 A7E :� ' ` 954-755-4402 BREEN RESIDENCE N.E.10401 STREET 1481 N.E. 904 STREET MIAMI SHORES, FLORIDA 33138 — — — — — — — — — — — — — — — — — — — — — — — 0 Femando Morales,P.E. ri)m lox- SM S.W.16 LEGAL DESCRIPTION SITE PLAN i f 11 i f 11 i1%'0 MWW,Flodda 33185 LOTS 10&11,BLOCK 3 N.T.S. 7"WO'OM RIVER BAY PARK ADDN Licerlae#51441 PLAT BOOK 40,PAGE 72 JOB#67030 PER FBC-RESIDENTIAL R4101.17: THE POOL SHALL BE LOCATED IN A — — — — — — — — — — — — ALL DOORS AND WINDOWS MANOR THAT COMPLIES WITH N.E.C. SEAWALL ON PROPERTY LINEALL DIRECT ACCESS FROM 680.8 FOR OVERHEAD CONDUCTORS THE HOME TO THE POOL SHALL BE AND N.E.C.680.10 FOR ALL 12'-1Q° EQUIPPED WITH AN EXIT ALARM UNDERGROUND CONDUCTORS. 18'-10° COMPLYING WITH UL 2017. 5' I 12, THE POOL SHALL BE LOCATED IN A MANOR THAT COMPLIES WITH N.E.C. g- 680.8 FOR OVERHEAD CONDUCTORS 12T AND N.E.C.680.10 FOR ALL UNDERGROUND CONDUCTORS. iw la EXISTING I CONCRETE PAD TO REMAIN IPp I TWO STORY CONCRETE PAD F.F.E. RESIDENCEE1 a THE EXISTING FENCES MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SECTION 424.2.17.1 AS FOLLOWS: CBS W 424.2.17.1.1: THE EXISTING FENCE IS LOCATED ON THE PERIMETER OF THE POOL.IN THE Y AREA ON THE SAME PROPERTY', IRON GATE EQUIP I 424.2.17.1.1: TOP OF FENCE IS A MIN.OF 48'ABOVE GRADE MEASURED ON SIDE OF THE WISELF-CLOSI 8 PAD ZOp AMP METER BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL; SELF-LATCHING 4'CBS WALL 424217.1.1: THERE IS A MAXIMUM 2'CLEARANCE BETWEEN GRADE AND THE BOTT THE MECHANISMS FENCE; LOCATED A MIM. r----------------1 / 4242.17.1.2: THERE ARE NO GAPS,OPENINGS,INDENTATIONS THAT ALLO CHILD TO OF 54'ABOVE I i / OVER,UNDER OR SQUEEZE THROUGH; GRADE 424.17.1.4: THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL ME IS LESS ON GATES / I 45';THE HORIZONTAL MEMBERS ARE ON THE POOL SIDE OF THE FENCE; SPACING WISELF--CL•OSING BETWEEN THE VERTICAL MEMBERS DOES NOT EXCEED 1-NW; DRAIN FIELD i _ SELF-LATCHING 424.17.1.5: THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMB SIS RE; MECHANISMS THE SPACING BETWEEN THE VERTICAL MEMBERS DOES NOT EXCEED 4°. SEPTIC LOCATED A N. IN ADDITION,THE FENCE GATE(S)MEET THE REQUIREMENTS OF THE FLORL B N E i / TANK OF 540 ABOVE SECTION 4242.17.1.6: GRADE I EXISTING GATE(S)ARE SELF-CLOSING AND HAVE A SELF-LATCHING LOCKING D I `--------------�-j t I ON THE POOL SIDE OF THE GATE(SX THE MECHANISM IS PLACED SO THAT IT CANNOT BE REACHED BY A YOUNG C / TOP OR THROUGH ANY OPENINGS OR GAPS FROM THE OUTSIDE; / THE GATE(S)SWING OUTWARD AWAY FROM THE POOL; / ! GATE(S)AND BARRIERS HAVE NO OPENINGS GREATER THAN 12'WITHIN l8'' MECHANISM; I 1! THE DEVICE RELEASE MECHANISM IS LOCATED NO LESS THAN 54'FROM THE TT / t `,N11Hb t rrrll�� GATE AND IS NOT LOCATED ON POOL SIDE OF GATE. �Op Al MO ...... 414 ll / f y NC — — — — —+ — —150.00'PROPERTY LINE — — — — — — -_'� F" er Ir O 12'PARKWAY SHEET 6: SITE PT�AN '• O ,,,.. •; VAN KlRKAND SONS • • •• • • • • • s'l1a�NAx- 3144 S.W.l3di DRIVE EACH,FL 33442 ••• ••i ••i ••• i•i • •• 954-755.4402 BREEN RESIDENCE N.E.104th STREET 1481 N.E. 1 ft SfREET.•• ••: ••• ••• MIAMI SHORE.MR-OVIDA Wr • • • • - - - - - - - - - - - - - - - - - - - - FemandoMoreles,P.E. • •• • • • • • • 5201 sw.la2rhaoe LEGAL DESCRIPTION ••• • .• • •• • SITE PLAN MWW,ale 33185 LOTS 10&11,BLOCK 3 N 7 3 tJ786.38 .973 41 RIVER BAY PARK ADDN *00 • • . • ••• • PLAT BOOK 40,PAGE 72 gOB#257030 c PER FBC-RESIDENTIAL R4101.17: THE POOL SHALL BE LOCATED IN A ALL DOORS AND WINDOWS MANOR THAT COMPLIES WITH N.E.C. SEAWALL ON PROPERTY LINE PROVIDING DIRECT ACCESS FROM 680.8 FOR OVERHEAD CONDUCTORS THE HOME TO THE POOL SHALL BE AND N.E.C.680.10 FOR ALL 12'-10" EQUIPPED WITH AN EXIT ALARM UNDERGROUND CONDUCTORS. 18'-10" COMPLYING WITH UL 2017. 8�• I 118'-6" THE POOL SHALL BE LOCATED IN A MANOR THAT COMPLIES WITH N.E.C. 12' 680.8 FOR OVERHEAD CONDUCTORS 122'-8" AND N.E.C.680.10 FOR ALL UNDERGROUND CONDUCTORS. OUSCONCRTENPAD NO OREVIEW REQUIRED TO REMAIN Health Miami-Dade County O.S.T.D.S. &well Program Application No.: { Date: Its ��9*� signature ." TWO STORY EXISTING RESIDENCE THE EXISTING FENCES MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SECTION CONCRETE PAD F.F.E.=8.51' 4242.17.1 AS FOLLOWS: { 9! 4242.17.1.1: THE EXISTING FENCE IS LOCATED ON THE PERIMETER OF THE POOL IN THE*#Ap 8'CBS Wz 1 I AREA ON THE SAME PROPERTY; • • 0000 •• •• IRON GATE 4242.17.1.1: TOP OFFENCE IS A MIN.OF 48°ABOVE GRADE MEASURE0QVtI[r-OF TIJF•• • • EQUIP. BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL; W/SELF-CLOS! • • •• :• SELF-LATCHING &PAD 200 AARP METER 4'CBS WALL 424217.1.1: THERE IS A MAXIMUM 2°CLEARANCE BETWEEN GRADE ANISE BOTTOM OF Tom` FENCE; •••••• • • • MECHANISMS 4242.17.1.2: THERE ARE NO GAPS,OPENINGS,INDENTATIONS THAT ALL0WA CHILD TO CLIMB :• •: LOCATED A MIN. r----------------� / ° � � OVER,UNDER OR SQUEEZE THROUGH; 96649* :••••• •• • OF 54B OVE I i / 424.17.1.4. THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL Bq IS LESS j •• •• zi { / ON GATES / I 45°;THE HORIZONTAL MEMBERS ARE ON THE POOL SIDE OF THE FENOE;THE SPA ; W/SELF-CLOSING, BETWEEN THE VERTICAL MEMBERS DOES NOT EXCEED 1-&4'; 00 •• •••• •• • DRAIN FIELD ~ �( SELF-LATCHING 424.17.1.5: THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTALS1S 45'OR MORE;00 / --� — MECHANISMS THE SPACING BETWEEN THE VERTICAL MEMBERS DOES NOT EXC4 • • •• :• LOCATED A MIN. IN ADDITION,THE FENCE GATE(S)MEET THE REQUIREMENTS OF THE Fj-ORIq/►BUILDIjA • / TANKSEPTIC OF 54"ABOVE SECTION 4242.17.1.8: • • • • • GRADE { EXISTING GATE(S)ARE SELF-CLOSING AND HAVE A SELF-LATCHING LOCMNG 5EVICE4.6CIM L -L-J ON THE POOL SIDE OF THE GATE ft •• • J { THE MECHANISM IS PLACED SO THAT IT CANNOT BE REACHED BY A YOUNG CHID)OVER THE / I TOP OR THROUGH ANY OPENINGS OR GAPS FROM THE OUTSIDE; / THE GATE(S)SWING OUTWARD AWAY FROM THE POOL; / I GATE(S)AND BARRIERS HAVE NO OPENINGS GREATER THAN 1/2"WITHIN 18°OF THE RELEASE DRIVEWAY MECHANISM; 3� { THE DEVICE RELEASE MECHANISM IS LOCATED NO LESS THAN 54°FROM THE BOTTOM OF THE / I GATE AND IS NOT LOCATED ON jlDE OF GATE. I < y. REVISION 06130/15:MO TO SIDE P LINE FROM (-� �E�TY UNEPOOL WATERLINESHEET 6: SITE PLAN TE 12'PARKWAY _ VAN KIRK AND SONS 3144 S.W.13th DRIVE - - - - — DEERFIELD BEACH,FL 33442 964-7554402BREEN RESIDENCE 1481 N.E. 104 STREET N.E.104th STREET' MIAMI SHORES,FLORIDA 33138 Femando Morales,P.E. — — — — — — — — — — — — — — — — — — — — — — — 5201 S.W.182 awe LEGAL DESCRIPTION SITE PLAN Mira.Rod&33185 LOTS 10&11,BLOCK 3 w.rs 786'380' RIVER BAY PARK ADDN Ucerm#51441 PLAT BOOK 40,PAGE 72 JOB#57030