Loading...
RF-16-123 �3 iz• 1 Miami Shores Village 10050 N.E.2nd Avenue NE E� 1 ••n Miami Shores,FL 33138-0000 Phone: (305)795-2204 qK � y��p► '9 a Expiration:08/02/2016 Project Address Parcel Number Applicant 1431 NE 102 Street 1132050240180 JOHN KEALY Miami Shores, FL Block: Lot: Owner Information Address Phone Cell JOHN KEALY 1431 NE 102 ST MIAMI SHORES FL 33138-2621 Contractor(s) Phone Cell Phone Valuation: $ 23,000.00 OBENOUR ROOFING SHEET METAL 1305-757-2612 Total Sq Feet: 3625 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF ENTIRE RESIDENCE WITH BORAL Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-1-16-58353 CCF $13.80 02/04/2016 Check#:7992 $830.56 $50.00 DBPR Fee $4.88 DCA Fee $4.88 01/14/2016 Check#:7961 $50.00 $0.00 Education Surcharge $4.60 Bond M 2981 Permit Fee-New Roof $325.00 Scanning Fee $9.00 Technology Fee $18.40 Total: $880.56 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,P MBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT• I ify th all the for in nformation is accurate d t tall work will be done in compliance with all applicable laws regulating construction an zo g. herm ,I aut riz above-named con7�717* rk stated. February 04,2016 A o ed Signature:Owner Applicant / Contractor / Agent e Buil ing Department Copy February 04,2016 1 3EOTECMUCAL I MWWNMENTAL I MATERIA i s TESTING A8BE8To8 I ROOF TESTING IINSPECTION SERVICES I DRUIMG SMMCES r H ENGINEERING_DECDYNATEC CORP, W`WW.DYNATECHENOINEERING.COM CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 MIAMI,April 25,2016 PERMIT No. CLIENT:Jim Obenour:OBENOUR ROOFING:9822 NE 2nd Avenue,Suite 9,Miami Shores,FL 33138 PROPERTY ADDRESS: 1431 NE 102ND STREET MIAMI SHORES,FL 33138 TILE TYPE/ATTACHMENT:Double Roll Roof Tile Polyfoam Set. Inspected By:JM Testing Equipment:Humboldt Scale Model H-4620 The test results presented here reflect the condition of the roof system at the time of the test These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and rooftop traffic Test No. Test Location Field Uplift Pull Test Test Result 1 -62 Field See Sketch Below >Than 35 LBS Passed 63-70 Comer See Sketch Below >Than 35 LBS Passed 71 - 101 Perimeter See Sketch Below >Than 35 LBS Passed 102-134 Ridge caps See Sketch Below >Than 35 LBS Passed ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 ROOF SKETCH � 54 53 �84 81 ; 1 52 18 50L-85---86---8- 51 8 i 59 11 47 43 44 45 46 8 80 58 49 -- 90_ 91_ 6 11 42 41 40 39 38 37 36 60 48 1 92 79 ' 11 0 31 32 33 34 35 25 57 2 61 55 29 28 27 13 16`21 1 24 193 96 7 81 26 ; 78 56 19. 22 1 12 11 10 9 � g 12 `2l)• 2_3 :94 1_ 77 13 14 15 16 17 "Z 95 7 2. r-------------------12 96 4 '10 100 99 98 97 76 , 4 1 71 �A®® 75 '62 3 2 Sincerely yours, - - - / — ----------- ----1fs'K=-� -- .7 / -(//�/{j���{QQQQ(� ,�c `• y "d - t � Wissam ani,P.E. ... DYNA CH ENGINEERING CORP. 'no Florida Reg.No.39584 Special Inspector No.757 750 WEST 84TH STREET,HIALEAH,FL 33014 PHONE t305)828-7499 FAX CMM 828-9598 EbLknJ NFOODYNATECHENGnMRMG COM #E"IC, .stn s Miami shores Village .... mum Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305)795.2204 Fax: (305)756.8972 RE: Permit# t` I—k-1 23 DATE: { INSPECTION AFFIDAVIT I lames Dlicensed as ann"t� /Engineer/ ( ) og Architect, (Pft nerne arw Circle Ucense TYR) FS 468 Building Inspector License#: C�-(i ®i Lt On or about 311-1 12, op I did personally inspect the roof deck nailing I(Dde&lkne) �� work at 102- <Jf(,�, l (Comlepte Job Si1eAddress) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual(Ba n 553.844 F.S) ign re State of Florida County of Dade: The undersigned, being the first duly swom,deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of Notary Public, Sate of Florida at large T- Expkes ry pair State or FbrWa andra Dee Hart y Cornmissron FF 010844 04f21l2017 *Geral,Bukft,PWIdentlal.orRwft Conha*rs or bdvWW t,effled wder469 f.S. make such an Inspedim Include of d ane of ft mofwfth perm#and address#dearly shoarn=*ed on the deck for each Inspection ti4tAe&A� t7t4nm4AW..F)4P)tM