RF-16-123 �3 iz•
1
Miami Shores Village
10050 N.E.2nd Avenue NE E� 1
••n Miami Shores,FL 33138-0000
Phone: (305)795-2204 qK �
y��p►
'9 a Expiration:08/02/2016
Project Address Parcel Number Applicant
1431 NE 102 Street 1132050240180
JOHN KEALY
Miami Shores, FL Block: Lot:
Owner Information Address Phone Cell
JOHN KEALY 1431 NE 102 ST
MIAMI SHORES FL 33138-2621
Contractor(s) Phone Cell Phone Valuation: $ 23,000.00
OBENOUR ROOFING SHEET METAL 1305-757-2612 Total Sq Feet: 3625
Type of Work:Re Roof Available Inspections:
Additional Info:RE ROOF ENTIRE RESIDENCE WITH BORAL Inspection Type:
Classification:Residential Up Lift Report
Scanning:3 Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00 Invoice# RF-1-16-58353
CCF $13.80 02/04/2016 Check#:7992 $830.56 $50.00
DBPR Fee $4.88
DCA Fee $4.88 01/14/2016 Check#:7961 $50.00 $0.00
Education Surcharge $4.60 Bond M 2981
Permit Fee-New Roof $325.00
Scanning Fee $9.00
Technology Fee $18.40
Total: $880.56
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,P MBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT• I ify th all the for in nformation is accurate d t tall work will be done in compliance with all applicable laws regulating
construction an zo g. herm ,I aut riz above-named con7�717*
rk stated.
February 04,2016
A o ed Signature:Owner Applicant / Contractor / Agent e
Buil ing Department Copy
February 04,2016 1
3EOTECMUCAL I MWWNMENTAL I MATERIA i s TESTING A8BE8To8 I ROOF TESTING IINSPECTION SERVICES I DRUIMG SMMCES
r
H ENGINEERING_DECDYNATEC CORP,
W`WW.DYNATECHENOINEERING.COM
CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH
FLORIDA BUILDING CODE TEST PROTOCOL TAS-106
MIAMI,April 25,2016 PERMIT No.
CLIENT:Jim Obenour:OBENOUR ROOFING:9822 NE 2nd Avenue,Suite 9,Miami Shores,FL 33138
PROPERTY ADDRESS: 1431 NE 102ND STREET MIAMI SHORES,FL 33138
TILE TYPE/ATTACHMENT:Double Roll Roof Tile Polyfoam Set. Inspected By:JM
Testing Equipment:Humboldt Scale Model H-4620
The test results presented here reflect the condition of the roof system at the time of the test These results are time and sample dependent since
roof condition are continuously changing due to the exposure to the element and rooftop traffic
Test No. Test Location Field Uplift Pull Test Test Result
1 -62 Field See Sketch Below >Than 35 LBS Passed
63-70 Comer See Sketch Below >Than 35 LBS Passed
71 - 101 Perimeter See Sketch Below >Than 35 LBS Passed
102-134 Ridge caps See Sketch Below >Than 35 LBS Passed
ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106
ROOF SKETCH
� 54 53 �84
81 ; 1 52 18 50L-85---86---8-
51 8
i 59 11 47 43 44 45 46 8
80 58 49 -- 90_ 91_ 6
11 42 41 40 39 38 37 36
60 48 1 92
79 ' 11 0 31 32 33 34 35 25
57 2
61 55 29 28 27 13 16`21 1 24 193
96 7 81 26 ;
78 56 19. 22 1
12 11 10 9
� g 12 `2l)• 2_3 :94
1_
77 13 14 15 16 17 "Z 95
7 2. r-------------------12 96
4 '10 100 99 98 97
76 , 4 1 71 �A®®
75 '62 3 2
Sincerely yours, - - -
/ — ----------- ----1fs'K=-� -- .7 / -(//�/{j���{QQQQ(� ,�c `• y "d -
t �
Wissam ani,P.E.
... DYNA CH ENGINEERING CORP. 'no
Florida Reg.No.39584
Special Inspector No.757
750 WEST 84TH STREET,HIALEAH,FL 33014 PHONE t305)828-7499 FAX CMM 828-9598 EbLknJ NFOODYNATECHENGnMRMG COM #E"IC,
.stn s Miami shores Village
.... mum Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305)795.2204
Fax: (305)756.8972
RE: Permit# t` I—k-1 23 DATE: {
INSPECTION AFFIDAVIT
I
lames Dlicensed as ann"t� /Engineer/
( ) og Architect,
(Pft nerne arw Circle Ucense TYR) FS 468 Building Inspector
License#: C�-(i ®i Lt
On or about 311-1 12, op I did personally inspect the roof deck nailing
I(Dde&lkne) ��
work at 102- <Jf(,�, l
(Comlepte Job Si1eAddress)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit
Manual(Ba n 553.844 F.S)
ign re
State of Florida
County of Dade:
The undersigned, being the first duly swom,deposes and says that he/she is the contractor for the above property
mentioned.
Sworn to and subscribed before me this day of
Notary Public, Sate of Florida at large T- Expkes
ry pair State or FbrWa
andra Dee Hart
y Cornmissron FF 010844
04f21l2017
*Geral,Bukft,PWIdentlal.orRwft Conha*rs or bdvWW t,effled wder469 f.S. make such an Inspedim Include of d ane of ft mofwfth
perm#and address#dearly shoarn=*ed on the deck for each Inspection
ti4tAe&A� t7t4nm4AW..F)4P)tM