RF-15-3121 Inspection Worksheet
z Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-249535 Permit Number: RF-12-15-3121
Scheduled Inspection Date: February 24,2016 Permit Type: Roof
Inspector: Rodriguez,Jorge Inspection Type: Final Roof
Owner: OLASO, M CLAUDIA Work Classification: Tile
Job Address:55 NE 99 Street
Miami Shores,FL Phone Number
Parcel Number 1132060131290
Project <NONE>
Contractor. FLORIDA E Z REMODELING INC Phone: (305)796-6753
Building Department Comments
NEW ROOF FOR ADDITIONAL ONLY Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed
Failed
Correction
Needed
Re-inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid
February 23,2016 For Inspections please call: (305)7624949 Page 9 of 40
Lab Report No. 125614
FLORIDA TEC
PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY
e v C.A.#30448
Lab Certificate#13-0507.02
CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE
TO COMPLY WITH METRO-DADE COUNTY PROTOCOL TAS-106
PROPERTYADDRESs: 55 NE 99th St,Miami Shores PERN17TNo: RF12153121
ROOFING
OWNER. SQUARES: 4
CONTRACTOR: Oroni Inc. ROOF pmm..• 3:12
INSPECTOR
TILE TYPE.--Spanish"S INrnws: JC
ATTACHMENT:• POlyfOam TEsT DATE. 2/11/2016
Testing Equipment: Digital Chatillon DFIS 200 Test Tabulation Required Testing Force:35 lbs
No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT
1-3 Passed
THIS ROOF HAS:PASSED ® FAILED❑THE STATIC UPLIFT IN ACCORDANCE WITH MU MI-DADE COUNTY TAS 106.
//, NOT TESTED
i ,
19'
3
Alberto Cardona,P.E.
Lic.No.J708 16' --�
10735 SW 216''St. Unit 416 Tel:305-256-4550
Miami FL 33170 Page 1 of 1 Fax:305-256-6833
www.FloridaTEC.net
Miami Shores Village I
10050 N.E.2nd Avenue NE
Miami Shores,FL 33138-0000
` Phone: (305)795-2204
Expiration: 06/21/2016
ry
Project Address Parcel Number Applicant
55 NE 99 Street 1132060131290 M CLAUDIA OLASO
Miami Shores, FL Block: Lot:
Owner Information Address Phone Cell
M CLAUDIA OLASO 55 NE 99 ST
MIAMI SHORES FL 33138-2338
Contractor(s) Phone Cell Phone
FLORIDA E-Z REMODELING INC Valuation: $ 4,200.00
(305)796-6753
------___ ____....-..__. ... _ s �. _ Total Sq Feet: 400
Type of Work: Available Inspections:
Additional Info:NEW ROOF FOR ADDITIONAL ONLY Inspection Type:
Classification:Residential Up Lift Report
Scanning:3
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $3.00 Invoice# RF-12-15-58090
DBPR Fee $3.75 12/17/2015 Credit Card $50.00 $224.50
DCA Fee $3.75
Education Surcharge $1.00 12/24/2015 Credit Card $224.50 $0.00
Permit Fee-New Roof $250.00
Scanning Fee $9.00
TechnoloyFee $4.00
l
Tota -' $274.50
t.f.
Gr:
r
In consid?r7tion of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertainingMereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting8yis permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required fSPELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
.a.
OWNERS�'iFFIDAVIT• I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constructii�and z g. Futhermore,I authorize the above-named contractor to do the work stated.
December 24,2015
r
orized Signature:Owner / Applicant / Contractor / Agent Date
r-3
Buil�ng Department Copy
December 24,2015 1
Miami Shores Village
DECi 7 Zo�S
Building Department
� 11 10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949 S
FBC 20( q
BUILDING Master Permit No. Kt"' q-" �
PERMIT APPLICATION Sub Permit No. Ey- sI ?A.,,
❑BUILDING ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION E:1 SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: �S g115 R Ck
City: Miami Shores County: Miami Dade Zip: ?SA3$
Folio/Parcel#. X X- -0-13- 12.80 Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): CAQ&3�al cx OkO-SO Phone#:
Address: f>45 W-F— qat sknr -�-
City: gtra (i Shags, State: 'V—'L Zip: gs1-M
Tenant/Lessee Name: Phone#:
Email: `` 1
CONTRACTOR:Company Name: �10i1 Gil9, `E-&7 ReV40d6 /4!1 tMC Phone#:��.,) ��✓`.3
Address: 1005; 5 Lo 4 3 5T ,
City: M jav*L State:.. Zip: �►�/�.1"
Qualifier Name: wec:tb 00tra` cL16.� Phone#:
State Certification or Registration#: CCC- 132-tic S Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace„ :, ❑ Demolition
Description of Work:
Specify color of color thru tile:too,0
Submittal Fee$ Permit Fee_$ ' CO CCF$ �� CO/CC$
Scanning Fee$ C)Q!1 Radon Fee$ DBPR$ 2-'143 Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$��e � /���
TOTAL FEE NOW DUE$ -�'f”° S®
(Revised02/24/2014)
s
Bonding Company's Name(if applicable)
Bonding Company's Address '
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Si nature 4 &,a), Si nature
gg
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
sL day of 20 IS- ,by 1-1 day of Dec ewi bey .20 I S .by
C�QL'd:n, b G0.S0 ,who is personally known to Ne"t'or C_Arrc*a1'Q who is personally known to
me or who has produced lb L-*- c]l\7r NrR_ _ as me or who has produced IDL"* Qn '`r'l It as
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: U Sign-
Print: Print:
e,2
Seal: Seal: ✓�r'' T V*tw
" REBECA M.PASTRANA COmffftM IF FFM11
MY COMMISSION 0 EE872624 • . EIS QMmbQf 92x19
EXPIRES:February 07,2017 '�iy �� Boll VIN A8f011Vq
APPROVED BYyI/ , Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
2Q 16 details- Business Tax Account FLORIDA E Z REMODELING INC -TaxSys-Mia... Page 1 of 1
9
miamidade.Govt
Tare Collector Home Search Reports Shopping Cart
Please do not include any special characters in the name,address,and e-mail field such as#,&,hyphens,comma,
dashes.
We have moved.Our new address Is:
200 NW 2nd Ave,Miami,FL 33128
The information contained herein does not constitute a title search or property ownership.
2015 Tax Bills are Payable on Sunday,November 1,2015.
Business Tax Account#6040430 Account details . _,Account history
2016 2015 2014 2013 ... 2010
PAID PAID PAID PAID PAID
Account number: 6040430 Owner(s): FLORIDA E Z REMODELING INC
Business start date: 05/01/2007 10051 SW 43 ST
Business address: FLORIDA E Z REMODELING INC MIAMI,FL 33165
10051 SW 43 ST Mailing address: FLORIDA E Z REMODELING INC
MIAMI,FL 33165 HECTOR J CARRATALA PRES
Physical business location: UNIN DADE COUNTY 10051 SW 43 ST
MIAMI,FL 33165
Flags: Home Business
Print account application
{PDF}
PAID 2015-09-26$75.00
Contracting 10/01/2015 NAICS code: Receipt#CREDITCARD-15-049784 C11 Print
GENERAL BUILDING —09/30/2016 2389 this bili
CONTRACTOR Units:1
Documentation Required by Occupation: State/County License or Certificate
Document Received: CCC1328085
https://www.miamidade.county-taxes.com/public/business tax/accounts/6040430 12/17/2015
CERTIFICATE LIABILITY INSURANCE DUPUIS=
pnowim UN{WM IMM MM UMM AS A M A176t OF 01FDNSAATON
AAD ALL-L=ES INS ASSOC INC ONLY AND COMM SO MMM UPON TM CWVWATE
58{10 SW 135 Ave Ste 106 i! •TM CATS O NOT'AMS,0f1NND OR
Kiami, IPL 33183
NBAFFOROM
C4VEitA1 NIAICS
° 12AMIDA E-I itNODELIW6, INC. *=xtmk
10051 S.W. 43 ST. wsurac .
HUM, EL 33165
z
TH H OR CION OF ANY Cts mokcT OR OTMR DOCi mff WRN f�B W TO Y 144"a Cf3 a"WAM MAY Ss OR
MM �W IM POLt=OE �S MMaTO A"TM U MS.MLUSNSNS NO COMMOMOF WCN
wmELB fMAYMVWRETaE!!RE LIMBYPMCtAM
ughom LdAKM EACH
Y�mmew neIOaiI.M.
----
15-0187 09/18115 09118!18 "Mom 1,000-000AOOPS~GATE 2-000,000
ML
L9OT PEPC
MMULVMM
AMAMD _
ALLOVAMAUM
t
BatBaa�AtJTM nifR"
MM Now BOOLYOM;w
NON4YOMAMS mmmovoo _
PROPEMOAMAM f
L619Lt/Y
AWAWO dTHBlRTiUN
Auf oon�YAM I
LYI�AlTY EACH 221EMMM r�rnrr rrrr
0=0 ❑CAOMMAGE ASGREGM
woompsoomp TMNAND
auftoYERS'LLMMJTN ••„„„ „„
AEY www BL.EACH
baFtCHlMPwt B�.flGlOt
OTHM
11ON�Oi�aATHCISt1:0OATiDHB/VENIGFBJ OBYE JSAErditl.
& Rt1OrM COWMAsCTOR
CITY OF mimes SNOP49S sfioLLnANYof T�ABa�re Pa res BE e�wawN
stri xm DEBAR DATE THEMOF,TQM MMus INSURER WLL DAYS WMfryM
10050 HE 2ND AV==
NWOMTOTMCENTIPtCATEMOLMNAMED THEWT.BHHTP CTO-00MMALL
OR
�' SHOMS, 9'L 33138 X 118 ofLtf;ATfav oa rrfp AORM
ftx (305} 756-8972
ACOMUPM)j RAC4� ORAT M988
Aft
,iii AtMgtty9p
CHW IPMANCIAL OWNWR STATE OF FLORIDA
DEPARTtMENT OF FINANCIAL SERVICES
DMSION OF WORKERS'COMPENSATION
'•CERTIFICATE OF ELECTION TO BE EXEAWT FROM FLORIDA WC$tKFJMI COWMNSATiON LAW•,
CONSTRUCTION INDUSTRY EXEMPTION
Ttuss cWtOw that the indN dwt listed below has OkKAOd to be exec rV from Florida ftykem'Compensabon low.
EFFECTIVE DATE: 7118=15 EXPIRAT I DATE: 71151.2017
PERSON: CARRATALA HECTOR
FEN: 201226350
BUSHOEW14AW AND ADDRESS.
FLORIDA E Z REMODELING INC
10051.9W-43 ST
M AN FL 83165
SCOPES OF BUSINIM OR TRADE:
LICENSED GENERAL LICENSED ROOFING
CONTRACTOR CONTRACTOR
PtuauWd 4Sty.{t5llaj S.ara a oT a exanvdm tcatn triis doov by+;;�s c4r to of low -AS sez�nNin
*�r or smarm _ m A40�QX4(72}.F.3.. a d efes8o^t hi keel..aper onto
wQtth dos sWP of ftar Of is d On ft nub=OUciton lobe skan4d.FhrWArd to Chi 4ft0 j%F,S,kdms d n w be
esempf aed MWAsm al dwsm to toMOW 00 be in mvamum W.m any*m dker ft s"of ft noon ar ft brAKM doe cWtIfteft.
me pmt p rotobed as on"aft*or cwtftw fm#Dtw" bre requmnerm w to wman far WOUrAW Ofa ate.The aeperUMM OW make a
DFS�F2,DVYC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 0&13 OUESTIONS?t8W}41306W
FLORIDA - E ELING INC`
ROOFING AND GENERAL CONTRACTOR
10051 SW 43th ST MIAMI FL 33165
PHONE (305)796-6753
ENJAL: HECTORI910YAHOO.COM
Date:Dee-,m6e r 1-1, 210 LS
State of r—L-
County of-_K u►►M:- bad e
Before mi this day personally appeared r"I( r ,rral \a who,
being duly swom,deposes and say:
That he will be the only person on the project working at e t%le C1°I S-r
SWEto(affirmed)and subscribed More me this qday of rwern be., ,20_!5 by
Personally Know
OR Produced Identification O n fl 4e
Type of Identification Produced L
.,; $*P T.Vasquez
COMMUm # FF9011
.•r Vis:DWft 9,2019
WW thru Aaron NotaryPrin Or a of tary
STATE LICENSE CCC-1328085
STATE LICENSE CGC-058612
4
Eggs CU Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Notice to Owner— Workers' Compensation Insurance Exernption
211-11 , 011- W,
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers'Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full-time
employees,including the owner,must obtain workers'compensation coverage. Corporate officers
or members of a limited liability company (LLC) in the construction industry may elect to be
exempt if
1. The officer owns at least 10 percent of the stock of the corporation,or in the case of
an LLC,a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State,Division of Corporations;and
3. The corporation is registered and listed as active with the Florida Department of
State,Division of Corporations.
No more than three corporate officers per corporation or limited liability company members are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
Your contractor is requesting a permit under this workers'compensation exemption and has acknowledge that he or she will not use
day labor,part-time employees or subcontractors for your project.The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project.In these circumstances,Miami Shores Village does not require verification of
workers'compensation insurance coverage from the contractor's company for day labor,part-time employees or subcontractors.
BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS
CONTENTS.
Signature: a"Op,
Owner
State of Florida
County of Miami-Dade
The foregoing was acknowledge before me this day of J?�l 20 %_5
By who is personally known to me or has produced
L„ as identification.
Notary:
SEAL: RE13ECAR PASTRANA
My COMMISSION 9124
L ap OMES.Fvbkn�-�y 07.2X017
`5 L' Miami Shores village
Wes 4n. Building Department
°2 10050 N.E.2nd Avenue
�lpR�pA Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE.
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date: M2 2-
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: K Cka 'fa taco
Property Address: 55 1AE 9q 5I
Roofing Permit Number.if-12-15.3121
Dear Building Official:
I M Gtcw,dia► 0 kQ= certify that I am not required to retrofit the roof to wall connections of my
building because:
Whe just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions
of 1994 edition of the South Florida Building Code(1994 SFBC)
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom,deposes and says that he/she is the owner for the above property mentioned.
Swom to and subscribed before me this 2.3r° day of J)&&wJner
So"T.Vasquez
Notary Public, Sate of Florida at Large Eou Deomber 9,2019
,p BonM thru Aaron Notary
• when the Just valuation of the structure for purpose of ad valorem n is equal to or more than$300,000.00,and the building was not constricted with FBC nor a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to wall connection Hurricane Mitigation.
Revised on 5121/2009
Prope Search Application-Miami-Dade County Page 1 of 1
0. OFFICE OF THE PROPERTY APPRAISER
Summary Report
Generated On:12/23/2015
Property Information
Folio: 11-3206-013-1290
Property Address: 55 NE 99 ST
Miami Shores,FL 33138-2338
Owner M CLAUDIA OLASO
Mailing Address 55 NE 99 STMIAMI SHORES,FL 33138-2338
Primary Zone 1000 SGL FAMILY-2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL-SINGLE
FAMILY:1 UNIT ,.
Beds/Baths/Half 2/1/0
Floors I
v..
y
Living Units 1 y
Actual Area 1,876 Sq.Ft s=r n
Living Area 1,259 Sq.Ft ;
Adjusted Area 1,504 Sq.Ft Taxable Value Information
Lot Size 8,625 Sq.Ft
2015 2013
Year Built 1938
2014
County
Assessment Information Exemption Value $50,000 $50,000 $50,000
Year 2015 2014 2013 Taxable Value 1 $66,005 $65,085 $63,385
Land Value $164,082 $164,082 $112,453 School Board
Building Value $107,588 $105,693 $106,579 Exemption Value $25,000 $25,000 $25,000
XF Value $1,711 $1,729 $1,746 Taxable Value $91,005 $90,085 $88,385
city
Market Value 1 $273,381 $271,504 $220,778
Assessed Value $116,005 $115,085 $113,385 Exemption Value $50,000 $50,000 $50,000
Taxable Value $66,0051 $63,385
Benefits Information Regional
Benefit Type 2015 2014 2013 1 Exemption Value 1 $50,000 $50,000 $50,000
Save Our Homes Assessment Taxable Value $66,005 $65,085 $63,385
Cap Reduction $157,376 $156,419 $107,393
Homestead Exemption $25,000 $25,000 $25,000 Sales Information
Second Exemption $25,000 $25, ,000 Previous Sale Price OR Book-Page Qualification Description
Homestead 000 $2510/01/1995 $84,000 16950-2574 Sales which are qualified
Note:Not all benefits are applicable to all Taxable Values(i.e.County, 12/01/1986 $62,000 13125-2303 Sales which are qualified
School Board,City,Regional). 12/01/1973 $43,500 00000-00000 Sales which are qualified
Short Legal Description 08/01/1973 1 $32,000 00000-00000 1 Sates which are qualified
MIAMI SHORES SEC 1 AMD PB 10-70
LOT 18&E1/2 OF 17 BLK 9
LOT SIZE 75.000 X 115
OR 16950-2574 1095 1
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser
and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
http://www.miamidade.gov/propertysearch/ 12/23/2015
.=* I I
• ' • •
Z � � • �
• • ■ • • • ■ • • ■ • ; Z7
-1.
■WIrlLWCi buvmciwWrw=wC=CCW:.iir■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
iiiii■■E■■mm■■11■■■mm■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■E■■■■■■
mqLI■■■■'.1,n■■■11■■Cr7.�11i.i.=..■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
• UNEIM■■■UMN-0–R1!ww=== Groni■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
ilii■■■■■mm■■11■■■■■■MM■119E■MM■M■■MMMM■■M■■■■■■MM■■MMMMMM■■■■
ILoa>1■■■I/Ilit��rw.■..r. Suitt■N■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
ilii■■■■■11■IFIL■LI■/1 %till�lt1■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
111�!��l�f.flR.Tl<!,iii�'I li SQL 13i~4�M INC■MPETMEwwww ■■ 1■■
VViiWiilN■O■■■■■Eli■■----1■11■■I■►�■■■■■■■■!■■ •• • - 1■■
■■■■!.!!�r�1.1R��'�"�t�iin��T:�?■■I■11■l<i■�III■■■■■■■■■■■■■■■■■■■■■■■■■>z■r■■
�il!L9�lilli�'iiiliiiW'Iiiirirrrrrr.._•^�:�J■■rLw■■■�l�■■■■■■■■■■■■■■■■■■■■■■■■■
w��■■.■■t:�n■■■■■�►1■■yin■r.►�■■■■i■■�■■■■■■■■■■■■■■■■■■■■■■■■■■
._t Y■f■■y�Gl�%■I■■■/I■■/I\`�I//■Li■I■/■CC�C:7■1'�������������■■■■■■■
■■■■■■■■■■■■■I■■■11�7\i/I■/./■I■��■!■■■■■1 • • - NOON■■■
■■■■■■■■■■■■1%■■■■�%■I■/�■I■/�■II■■■■■1 NOME
l ■fi■/./■%■/I■I%O/J■NOON■■M■■■M■ON■M!�■�!!�ltll�!!�
Mow, OWMISNP.11P
■■■■■M■■■■EMM■■■■■■■■■■■■mow.■■■■■■■■■■■■■■M■■■■,�;■->. .�■■`�■■�;w
■■■■■■■■■■■■■■■■■■■■■■■■■■t■■■■NOON■L■■t■t■■■t/n!��■mow■)!�■1■�
'zl
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: Santafe Tile Corporation
Product Approval Number: 12-0210.01
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
P1: 47.6 p2: 100.6 p3: 100.6
......
Maximum Design Pressure � �.� ....�.
Product Approval Specific System: 45.5 .. ..
...... . .. ......
Method of Tile Attachment: 3M 2-COMPONENT FOAM ROOF TILE AS-160 ';;;;' ••••
....%
.... . .....
...... ... . .....
.. .. .. ......
Steep Sloped System Description ; ;
Deck Type: 15/8 INCH PLYWOOD 6556
Roof Slope: Type Underlayment: ASTM D 226 TYPE 11 #30
4 : 12
Insulation: N/A
Fire Barrier: N/A
Fastener Type&Spacing:
Ridge Ventilation? 1 1/4" R.S.CORROSION RESISTANT
CONTINUOUS
Adhesive Type:
F3M 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160
Type Cap Sheet: ---
POLYGLASS POLYSTICK(PEEL AND STICK)
Roof Covering:
Mean Roof Height:
13' 1
SANTA FE CLAY ROOF TILE(COLOR THRU)
Type&Size Drips
Edge: 3 INCH 26 GAUGE
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Section E (Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values
for Mrwiththe values from Mt.If the Mr values are greater than or equal to the M,
values,for each area of the roof,then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
(P,• 47.6 X .297 - 14.14 )-Mg: 5.69 =Mrt 8.45 Product Approval K-61.9
(P2; 100.6 XX 297 a 29�-Mg: 5.69 c Mr2 24.19 Product Approval Mt 61.9
(P3: 100.6 XX .297 = 29.88 )-Mg: 5.69 a Mrs 24.19 Product Approval Mt 61.9
Method 2 "Simplified Tile Calculation Per Table Below"
Required Moment of Resistance(Mr)From Table Below Product Approval Mt
M R wired Moment Resistance*
Mean Roof Height--lo.
Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 4
3:12 32.2 34.4 36.0 37.4 9.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 26.4 28.0 29.4 300" 32.4
7:12 24A 25.9 1 27.1 8.2 30.0
*Must be in onlunc tion with a list/culations
based tits systems a orsed by the
Broward u Boistems
Rules and Ap
For Upli based use Meompare the lues for F'with the values for
Fr.if the 'values reater than oo the Fr v es,for each area of the roof,then
the tile a achmenhod is accep
Method 3"Uplift culations Per AS 12(P,: x 1: = x w:= - s& - =Fr, Product roval F'(P2: x 1: = x w:= - os 0: - =F vat F'
(P3: x 1: = x w:= )- os& - Fra Product Appro F'
Were to Obtain I formation
Description Sym 1 Where to find
Design Pressure Pt r P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof SI 9 Job Site
Aerodynamic Mui ler A Product Approval
Restoring Moment due toravity Ma Product Approval
Attachment esistance M, Product Approval
Required Mompf Resistance M, Calculated
Minimum Attac ent Resistance P Product Approval
RequWd Uplift Resistance F, Calculated
Average Ills Weight W Product Approval
lite DimensionsI'.length Product Approval
W-width
l calculations must be submitted to the Building Official at the time of permit application.
9
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING
' CONSIDERATIONS
R4402.13.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the
owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of
Section R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally,the following items should be addressed as part of the agreement between the owner and the
contractor.The owner's initial in the adjacent box indicates that the item has been explained.
_Pe6 -1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of
providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics
(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color
or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement
between the owner and the contractor.
P C.0 2.Renailing Wood Decks:When replacing roofing,the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403.(The roof deck is usually conce a4or
to removing the existing roof system.) . . ......
4k CL 3. Common Roofs: Common roofs are those which have no visible*88V8atioAetween ••••:•
neighboring units (i.e. townhouses, condominiums, etc.) In buildings with commed Ifts, the roofing �•.•.�
contractor and/or owner should notify the occupants of adjacent units of roofing wor fe&perfor . ����•
e 4.Exposed Ceilings: Exposed,open beam ceilings are where the underside:ofICe roof;eek. .....'
can be viewed from below.The owner may wish to maintain the architectural appearance0t6refore,roofing
nail penetrations of the underside of the decking may not be acceptable.This provides t
000600 tof m intai in •
aT g •
this appearance. ••••••
. . above•
5. Ponding Water:The current roof system and/or deck of the building may not drain%gl?add
may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of
structural distress and may require the review of a professional structural engineer. Ponding may shorten
the life expectancy and performance of the new roofing system. Ponding conditions may not be evident
until the original roofing system is removed. Ponding conditions should be corrected.
. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge
if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402,R4403 and R4413.
_J C&�7.Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of
the roof.
Exception:Attic spaces,designed by a Florida licensed engineer or registered architect to eliminate the attic
venting,venting shall not be required.
5
Owner's/Agent's Signature Date 4Contrto'r`sJSign_ature
&5- A1C 99 f 5t/V a.
Property Addrps�rS � Permit Number
�.i�� � s 33�3�
t , ,
MAMA MIAMI-DADE COUNTY
EW PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE_(NOA) www.miamidaae.eoviyera
Santafe Tile Corporation
8825 NW Oh Street
Medley,FL 33178
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within*their jurisdiction. PERA reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code. . "
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. :...:.
DESCRIPTION: Santafe Spanish`S' Clay Roof Tile ...... •.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or loo,•0g+J statevanand following'*':
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein!'• 46:906
...... ... . .....
RENEWAL of this NOA shall be considered after a renewal application has been filed and l erre has beef no chaAA8
in the applicable building code negatively affecting the performance of this product. ,0 00;
TERMINATION of this NOA will occur after the expiration date or if there has been a reisiair or changein the:"
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement oitry product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA'is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Oficial.
This replaces NOA# 10-1005.15 and consists of pages 1 through S.
The submitted documentation was reviewed by Alex Tigera.
NOA No.:12-0210.01
Muarranaue CO Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Clay
Deck Type: Wood
1. SCOPE
This approves a roofing system using Santa Fe"Santafe`S"Clay Roof Tile,as manufactured by Ladrillera
Santafe S.A. in Bogota,Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements,as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Santaf6`S' Clay Roof L= 18" TAS 112 One piece high profile clay roof tile equipped with
Tile W= 11.1" two nail holes. For nail-on,mortar set and adhesive
set applications.
Trim Pieces 1=varies TAS 112 Accessory trim,clay roof pieces for use at hips,
w=varies rakes,ridges and valley terminations. Manufactured
varying thickness for each tile profile. . . :0•"' 000 000
.. . 0
0 0 0
2.1 MANUFACTURING LOCATION
0:99:000 0 0 0 0 0 0••
0000..
0000..
1. Bogota,Colombia •••• • • • •
• ••••••
0000 . 00000
2.2 SUBMITTED EVIDENCE 0 0.0 0• 000
0
0000 .. 0000..
Test Agency Test Identifier Test Name/l.2cMcf# Date •0
. . . . 0000..
The Center for Applied Engineering,Inc. 94-156-8 TAS 101 0 ... -8g. 19$4
94-156-9 TAS 161-• 0 000 :0000
The Center for Applied Engineering,Inc. 25-7205-1 TAS 101 0•March 1995
The Center for Applied Engineering,Inc. Project:07-07-00-91 TAS 100 Sept. 1994
(307023)
Redland Technologies 7161-03 TAS 108 Dec. 1991
Appendix II (Nail-On)
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102&TAS 102(A)
Redland Technologies P 0402 Withdrawal Resistance Sept. 1993
Testing of Screw vs smooth
shank nails
CFDApE coe�rrrNOA No.: 12-0210.01
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 2 of 5
2.2 SUBM=D EVIDENCE
Test Agency Test Identifier Test Name/Renort Date
Redland Technologies P 0647-01 TAS 108 Aug. 1994
(Mortar Set)
Redland Technologies P 0631-01 PA 108 July. 1994
,(Mortar Set)
Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999
113A Consultants,Inc. 2353-4 Restoring Moment Aug. 1999
PRI Asphalt Technologies,Inc. SFTC-003-02-01 TAS 101 12/06/02
IBA Consultants,Inc. 2353-70 TAS 101 09/22/03
IBA Consultants,Inc. 2353-71 TAS 101 09/22/03
IBA Consultants,Inc. 2353-93 ASTM C 1167 07/18/05
3. LDmATIONs
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofin A !cadonsOStanOdards Usled.
Y P � pp � pl'i-.
section 4.1 herein. •• • •• •
3.5 30/90 hot mopped underlayment applications may be installed perpendiculaf'4b'MVroof sYop8 finless St'hfed'
otherwise by the underlayment material manufacturers published literature. 600606
:••••
3.6 This acceptance is for wood deck applications. Minimum deck requiremenft,S44H be ir:Lafnpliance Vrj#L
applicable building code. 000000 0 0 0
3.7 May be installed on slopes 7:12 and greater. 000000 0•: 6000:0
6....• 0
00
4. INSTALLATION 0 0 0 0 0 0 0 0 6 0
6666..
4.1 Santafe 'S' and its components shall be installed in strict compliance with RUbfiffg ApUffc$tt4n Standard•
RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W)and Dimensions(I x W)
Tile Profile Weight W(lbf) Length-1 (ft) Width-w(ft)
Santafe'S' 6.7 1.5 0.958
NOA No.: 12-0210.01
Expiration Date: 02/61/16'
JAPPROVED!_,i Approval Date: 05/31/12
Page 3 of 5
Table 2: Aerodynamic Multiplyers-.X(te)
Tile -%(ft ) A,(ft)
Profile Batten Application Direct Deck
Santafe'S' 0.274 0.297
Table 3: Restoring Moments due to Gravity-Mg(ft-lbf)
Tile 2"•12" 3"•12" 4':12" 5"12" 6"•12" 7"•12"or
Profile greater
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Deck Deck Deck Deck Deck I Deck
Santafe'S' 5.93 1 5.90 5.85 5.82 5.73 5.69 5.56 1 5.53 5.32 5.29 5.03 1 5.00
Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-ibf)
for Nail-On Systems
Tile Profile Fastener Type Direct Deck Battens
Santafe'S' 2-10d Ring Shank Nails 21.8 N/A
One#8 Screw 29.16 N/A
Two#8 Screws 38.28 N/A
One#8 Screw w/Clip 57.31 N/A
Two#8 Screws w/Clip 57.60 61.77
__l
1. Approved screws as noted'Product manufactured by others'.
2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment off(ft j ;•bf) •••• **0
00*
for Two Patty Adhesive Set Systems '..' .
• . •
Tile Tile Application �j"M n(m u m7 A achmen
ProfileRes to ce •••• •
Santafe'S' Tile Bond '... ' 8 •• ....
Polyfoam PolyproAH 160TA° 0000.0 2&64 . ..:. '
2 See manufactures component approval for installation requirements. •. .. •.. 0 0 0• .
3 Flexible Product,Inc.Average weight per patty 10.4 grams. . .
4 Polyfoarn Product,Inc.Average weight pera 9.4 grams. ' ' •
•0000•
Table 6A: Attachment Resistance Expressed as a Moment-Mt(ftNbf) •
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Santafe'S' Polyfoam Polypro AH 160Tm 63.8
Pol oam Pol ro AH 160T"' 61.9
5 Paddyplacement of 63 rams of Pol ro AH 160TM.
6 Paddy placement of 24 grams of Polypro AH 160Tm.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile Tile Attachment
Profile Application Resistance
Santafe'S' Mortar Set 23.6
NOA No,:12-0210.01
JAPPROVEMwr7Nntwe cD! r Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 4 of 5
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami-Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH"S"CLAY ROOF TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWING
When using one screw
use-this hole.
18" . . •
...... . .. ......
••9.9•
•
6666 •666••
• 6 •
• 6
6090 • 90.00
06.00• 009 • 00090
•• •• •• •096••
•
•9•••• 0 0
• • • •
• • • 0009000
•9009•
00
• • •
•• •
11.1"
"SANTAFb`S"CLAY ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 12-0210.01
raecout�nr Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 5 of 5
+ J
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN.55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3Mrm 2-Component Foam Roof Tile Adhesive AH-160
0000..
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logq a cty, sitp and following'
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein..... : 0 0 00 0 0.0:0
900.0. 9
0000..
RENEWAL of this NOA shall be considered after a renewal application has been filed Vd thgre hag Mpg no chhnge •
in the applicable building code negatively affecting the performance of this product. 0000
999999
TERMINATION of this NOA will occur after the expiration date or if there has bees i.revj'sion or change in thg'
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an en4orstdent of a�n�iprod=4 ofof:
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comRly wig lany sectio p f
this NOA shall be cause for termination and removal of NOA. 0• 0 0• :0: •
99 9
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0502.02 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0805.01
a ;COUId7 Y Expiration Date: 05/10/17
Approval Date:09/04/14
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in this Notice of Acceptance. For the locations where the design pressure requirements,as determined by
applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using 2-Component
Foam Roof Tile Adhesive AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3Mrm 2-Component N/A TAS 101 Two component polyurethane foam adhesive
Foam Roof Tile Adhesive
AH-160
Foam Dispenser N/A Dispensing Equipment
RTF1000
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOAr whichrist t
attachmen •;•
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof the g&hesfve. •.
...... . .. ......
MANUFACTURING LOCATION: 0::::o
••""
1. Tomball,TX. 0000
0000 .. 0000..
PHYSICAL PROPERTIES: 0000.. •
Property Test Results ••••••
Density ASTM D 1622 1.6 lbs./fft.3 ••• ••• •
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @1587., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.:14-0805.01
Mn�4oecauNnr Expiration Date: 05/10/17
Approval Date:09/04/14
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-1PA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 ;olOY28/98 .9•..
520109-2 • 00
520109-3 • '
520109-6
520109-7 •••• •
520191-1 TAS 101 "" '03/02/99 •
520109-2-1 ••�•'� •�•• �•���
.. .. .. ......
LIMITATIONS: • •
. . . . ......
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Asse%bry for fire tatial.
2. 3Mm 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tiTe profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3M7 2-Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 14-0805.01
APPROVED Coin Expiration Date: 05/10/17
Approval Date:09/04/14
Page 3 of 11
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance to meet or exceed the resistance value determined in compliance with Miami Dade County
Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A"component and the"B"component shall be maintained between 1.0-1.15(A): 1.0
(B)•
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or
ProPackO 30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight s%jga qin
accordance with the'Placement Details'herein. Each generic tile profile requires the spgooc placement noted•••:•
herein. •• • :09 go •
.09.40 9 .. ......
......
494099
:9:: 9 • • r
• r 9:r99
r::: r r99:0:
r •
9::r:: 099 r 090.0
09 r9 00 r4r:r:
•
•90:09 9 •
9 9 4 9 99::09
r4r::9
• • •
• 0
• r • :4:99:
go 0
MAWDADE_ NOA No.: 14-0805.01
Expiration Date: 05/10/17
Approval Date:09/04/14
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved"or the Miami-
Dade County Product Control Seal as shown below.
MlAM 1
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
.006.0
0000..
.. %
0000..
0000..
0000
0000..
0000 . 0000.
0000 .. 0000..
0000..
0000..
. . 0000..
.. 0000
NOA No.: 14-0805.01
. ;ED L Expiration Date: 05/10/17
Approval Date:09/04/14
Page 5 of 11
ADHESIVE PLACEMENT DETAIL# 1
Flat/Low Profile Tile
1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
°
2. Continue in same manner. Insure approximately 17
(109.7 cm)—23 (148.4 cm)square inch adhesive
contact with the underside of the tile.
Medium Profile/ Double Pan Tile
d
1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
10 R16
i 2. Continue in same manner.Insure approximately 17
(109.7 cm)—23 (148.4 cm)square inch adhesive
contact with the underside of the tile.
,1le
High Profile/Single Pan Tile
1. Starting at the eave course,apply a.minimum 2"
4s (50.8 mm)x 10"(254 provi I"(2,V min)foam••:-
paddy onto the underlayThent posifted gs shown•
SO es under the pan portion U W the cldsest to the
Overlock of the the being �t •• ••••;
00090 :**Goo
2. Continue in same manmi,.lnsure approximately.Z.'
° . (109.7 cm)—23 (148 Aocni5 square in*o4adhesive•:•
contact with the under=8f the tile. . •
b . . i...% ....i.
. . ......
NOA No.: 14-0805.01
ran�Fcouwn Expiration Date: 05/10/17
Approval Date:09/04/14
Page 6 of 11
ADHESIVE PLACEMENT DETAIL#2
Flat/Low Profile Tile
• 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17(109.7 cm)
23 (148.4 cm2)square inch adhesive contact with the
EM underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
Palm x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm)- 12 (77.4 cm2)square inch adhesive
contact with the underside of the tile.
Medium Profile/Double Pan Tile
$ 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
the being set. Insure approximately 17(109.7 cm2)—
'�` 2M. 23 (148.4 cm)square inch adhesive contact with the
underside of the tile.
i
2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overl"a£the tile
Pods 0 000000
being set. •
3. Continue in same mannes,ehAxse approximately 12"
.00000
(77.4 cmm
2)- 14(90.3 c � re ini*ogA sive • •
contact with the undersideV t'he tile.• ••;••.
.0.0.. 0 •
(Instructions continued on�iekt'ppge) •
0000..
0000..
.. 0000
V*to:
NOA No.: 14-0805.01
MW4M DFc?LWM Expiration Date: 05/10/17
Approval Date:09/04/14
Page 7 of 11
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
High Profile/Single Pan Tile
1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set.Insure approximately 17(109.7 cm2)—
'�' hL 23 (148.4 cm)square inch adhesive contact with the
underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the pan
t a portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner.Insure approximately 17"
(109.7 cm)- 19(122.6 cm2)square inch adhesive
contact with the underside of the tile.
...... . .. ......
.... . 09.6.
......
000 . 69604
.. .. .. 0.00•9
• • • • •9966•
•0090•
• • • •9996•
NOA No.: 14-0805.01
tl4DECOUNr�r Expiration Date: 05/10/17
Approval Date:09/04/14
Page 8 of 11
ADHESIVE PLACEMENT DETAIL#3
1. On the eave course only,apply a minimum 2" (50.8
® mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy
onto the underlayment positioned as shown,under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
aahL ' �, to the overlock of the tile being set.Leave
approximately 4" (10 1.6 mm)up from the eave
edge free of foam to prevent the expanded adhesive
asap. from blocking the weep holes. Insure
• • approximately 17-23 int(109.7-148.4 cm)of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4
- - - -- mm foam add onto the underla
) paddy yment just below
fbdAzwFkuMaTJk the second course line positioned foam paddy
under the strengthening rib for flat tile,or under the
pan portion of the tile,closest to the underlock for
the second course tile to be installed. Insure
OMdfftft approximately 8-9 int(51.6-58.1 cm2)of adhesive
contact with the underside of the tile.
w, (Instructions continued on next page)
* sada; =4�.
2�.
•••••• • •• ••••••
•
•••• • •••••
•••••• ••• • •••••
•• •• •• ••••••
•
• • • •14M ••••••
NOA No.: 14-0805.01
O��ueCouPrrY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 9 of 11
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x'/4"
(19 mm)paddy on top of the eave course rile
y surface as shown,on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of rile.
Install second course of tile.Insure approximately
9(58.1 cm2)- 11 (71cm2)square inch adhesive
contact with the underside of the file at the overlap
and 7(45.2 cm2)-9(58.1 cm2)square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
WaWhok
dome
High PmMolft
...... . .. ......
.... . .....
...... ... . .....
......
. . . . ......
.. . ...
NOA No.: 14-0805.01
!APPROVED
Expiration Date: 05/10/17
Approval Date:09/04/14
Page 10 of 11
s
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan)Tile
p1. Starting at the eave course,apply a minimum 2"
tyre �aar� ss�rasy.�n. t ►�� 1
, y (50.8 mm)x 0 (254 mm)x 1„(25.4 mm)foam
at + ►. e to paddy onto the underlayment positioned as
a►s�r. � crx an adjacent d shown under two atiles.
a� es�a► J p Support eave
Sb{n. a. tiles from rocking until adhesive has a chance to
., cure.
° a
• 2. Continue in same manner bringing two pan
� courses up toward the ridge.Insure
approximately 65 (419.4 cm)—70(451.6 cm)
square inch adhesive contact with the underside
of the pan tile.
tn+ ref 3. Turn covers upside down exposing the underside
of the tile.Apply a minimum 1”(25.4 mm)x 10"
(254 mm)bead of adhesive directly on the inner
+aeeaseceae•nwtea edge of each side of the cover tile.Leave
approximately 3/4"(19 mm)to 1"(25.4 mm)
Two 8ar*1_High Profile Tile from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20(129 cm) -25 (161.3 cm)square inch
contact area on each side of the c.overtile to the
pan tile. Continue in same manner.*'t`M away*••••
any cured exposed foam adhesivr.Fd4ting of •,
longitudinal edges 6M&Ubver tiles We
considered optional. ::: . ••••
. ......
.... . .....
5. When additional nail' ie requiwd,2':(50.8..:..'
mm)x 4"(101.6 mm6ilers or the tie+wire ••••••
system using galva*f,'4ainless steel,or •,
copper wire and colpatibre naill a4 be use'cr
END OF THIS ACCEPTANCE
NOA No.: 14-0805.01
M!APPR;EDI Expiration Date: 05/10/17
Approval Date:09/04/14
Page 11 of 11
' r
INIAMI�� ,
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DMSION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/sera
Polyglass USA Inc.
150 Lyon Drive
Fernley,NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the
right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there hass&no
change in the applicable building code negatively affecting the performance of this prodiQt• ; •
...... . .. ......
TERMINATION of this NOA will occur after the expiration date or if there has been a-rmsinn or change in th;••••
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an w1dd&rnen"a4);prodAct,
for sales,advertising or any other purposes shall automatically terminate this NOA. FailVZe;*o jomplywith any :::**.
section of this NOA shall be cause for termination and removal of NOA. •
.. .. .. ......
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,*-Florida, anlijifVred bythe:•
expiration date may be displayed in advertising literature. If any portion of the NOA:s dilplayed', then it sha=t.be.:
done in its entirety. •' .*•:• : •
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 11-0601.10 and consists of pages 1 through 8
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-1229.01
Expiration Date: 09/13/16
MIAMFDADE CO: Approval Date: 04/05/12
iAPPROVEDI
Page 1 of 8
e I
ROOFING COIVIP0NENT APPROVAL
Category Roofing
Sub-Category: Underlayment
Material: SBS ,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt
underlayment 65'8"x 3933/8" waterproofing membrane,glass fiber reinforced
Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for
#2 use as an underlayment for metal roofing,roof
tile, slate tiles and shingle underlayment.
Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering,
underlayment 65' x 3'3j/8" ASTM D 1970 APP polymer modified,fiberglass reinforced,
Manufacturing Location Or 65' x 3' bituminous sheet material for use as an
#1  60 mils thick underlayment in sloped roof assemblies.
Designed as an ice&rain shield and as a flat
roof tile underlayment.
Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP
underlayment 32'10'9 x 3'3j/8" ASTM D 1970 polymer modified,fiberglass or polyester
Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as
#1  an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering,glass-
underlayment 65' x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterproofing
(Surface Printing) 80 mils thick membrane. Designed as a metal r4Qfiug and roof
Manufacturing Location tile underlayment.
.. F. 0
0
.
#2 0000.. .. .0000.
0000..
0000..
Polystick TU P Roll: TAS 103 and A rubberized asphalt j ate..rproofiggmembrane,
0000.
underlayment 32'10"x 3'3j/8" ASTM D 1970 glass-fiber/polyester r4agWed,vtiib a granul#4;. •
Manufacturing Location 130 mils thick surface designed for use as a tile roof
#2 underlayment. •••••• •
0000..
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-Aheringr glass- :"'0
Manufacturing Location 61 x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterprdtlf ng
#2 60 mils thick membrane.Designed as a metal roofing and roof
tile underlayment.
Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass-
Manufacturing Location 61' x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and
roof tile underlayment.
NOA No.: 11-1229.01
Expiration Date: 09/13/16
MIAM4DADE COUNTY
... , Approval Date: 04/05/12
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton,PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Azency Test Identifier Test Name/Renort Date
Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01
11756.08.01-1 ASTM D 1970 08/14/01
02202.08.05 TAS 103 08/29/05
Trinity I ERD P5110.08.07 TAS 103 08/29/07
P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11
PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02
PUSA-005-02-01 ASTM D 4977 01/31/02
PUSA-018-02-01 ASTM D 2523 07/14/03
PUSA-035-02-01 TAS 103 09/29/06
PUSA-033-02-01 ASTM D 1970 01/12/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-083-02-01 TAS 103 06/30/08
PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09
Momentum Technologies,Inc. JX20H7A TAS 103/ASTM D4798&G155 04/01/08
RX14E8A TAS 103/ASTM D4798 &G155 11/09/09
DX23138B TAS 103/ASTM D4798 &G155 02/18/10
DX23D8A TAS 103/ASTM D4798 &G155 02418/10
•••••• • •• ••••••
•
•••• • •••••
•••••• ••• • •••••
•• •• •• ••••••
•
•••••• • •
• • • • ••••••
NOA No.: 11-1229.01
Expiration Date: 09/13/16
Muvra naa�counrr�r AVEDI_ pproval Date: 04/05/12
JAPPRPage 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6"o.c. at a minimum 4"head lap. (for
base sheet only)
Membrane: Polystick membranes self-adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-%2"and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special
attention to lap areas.
7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
.000.0
4
00 4 .0 0
. . 0
0000.. . .. 000900
0000..
0000
000000
0000..
0000 . 00000
040000 •00 . 00000
40 40 40 .40000
44404•
. 4 .4400.• 0*00:0
0
4 0
. . 0000..
00 0 0 000
0 4
NOA No.: 11-1229.01
Mu►Mana�co Expiration Date: 09/13/16
... EDI Approval Date: 04/05/12
Page 4 of 8
GENERAL LvvmATIONS:
1. Fire classificatidn is not part of this acceptance.
2. Polystick MTS,TU Plus,Tile Pro and Dual Pro may be used in asphaltic shingles,wood shakes and shingles,
non-structural metal roofing,roof tile systems and quarry slate roof assemblies. IR-Xe,TU,and TU P may be
used in all the previous assemblies listed except metal roofing.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times;not to exceed the preceeding maximum time limitations.
Expos re Limitations(days)
MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro
Winter Haven FL. 180 180 180 180 180 180 180
Hazelton,PA. N/A 30 30 180 N/A N/A N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.Polystick TU,TU Plus,and Tile Pro may be used in both adhesive set
and mechanically fastened roof tile applications. Polystick IR-Xe,and Dual Pro are limited to mechanically
fastened roof tile applications.Polystick MTS is limited to mechanically fastened with battens roof tile
applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)tile assemblies shall be as
follows: (See Table Below)
Tile Profile Polystick MTS Polystick IR-Xe Poly:tick • ,•T •�•••
Plus,"W P,Tale Pro
. . .•
...... . .. so**:*
Flat Tile Prohibited without battens 5:12 •°'R8-limitation ;,,,„
Profiled Tile 1 Prohibited without battens Prohibited .'�blimitaan.:.
The above slope limitations can be exceeded only by using battens and counter bad81914 accofft4with Qin•••
Approved Tile System Notice of Acceptance and applicable Florida Building Cod
•• •• ements. attens••• •
are required for both loading and installation of tiles at all times. ; • , •,.•;•
00 • •
NOA No.: 11-1229.01
Expiration Date: 09/13/16
MIA UHIXI COUNTY Approval Date: 04/05/12
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
z
Roofing Tiles
" (6 Max Per Stack)
2
12
06
a r
O g
N l y
� � t
'F
i
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe,TU,TU
Plus,TU P,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro is not listed,a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products,wind uplift
resistance,and fire testing results.
969.6.
6 6666..
LABELING: 0660 : .. .•
1. All membranes or packaging shall bear the imprint or identifiable marking of the > turer=s nj*me or 100,6
city and state of manufacturing facility and the following statement: "Miami-Dade.County grodgct Corp— •;
Approved"or the Miami-Dade County Product Control Seal as shown below. 0.6 600V0000 6 6 9.6
00.00.• 690 6 99.06
MO MI-DADE COUNTY .6 6. 00 6 6 9 6 9 6
6.96.. • •
• • 6 • 096696
BUILDING PERMIT REQUIREMENTS: 00*00 0....
.. . . .96
Application for building permit shall be accompanied by copies of the following: •9 0
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11-1229.01
Expiration Date: 09/13/16
!APPMIAMFDAROVED I TY Approval Date: 04/05/12
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1"metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of
12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on
the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area
being back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251
Premium Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic,applied in between the application of the lap.The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the tile manufacturers NOA's,must be used on all projects for
pitch/slopes of 7712"or greater. It is suggested that on pitch/slopes in excess of 6 '/a"/12",precautions
should be taken,such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
.00000
8. Polystick membranes may not be used in any exposed application such as crickets;exp8sed valleys,or ••••••
exposed roof to wall details.
0:009: •••. ••• •
9. Repair of Polystick membranes is to be accomplished by applying Polyglass PolypilLI; 15*PremiumModifiad •
Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass M300 MS Flaking
Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251 Prel".Wet/ISry Elastom�rwa
Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mag?r.td the area%deed qf.••••
repair,followed by a patch of the Polystick material of like kind should be set an(t1i dolled in place over
the area needing such repair.Patching membrane shall be a minimum of 6 inches i'n either dir ,q ,The ••••••
repair should be installed in such a way so that water will run parallel to or over tle pop of all ta•p hof the
patch. • • •
00 0
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request.It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894-4563.
NOA No.: 11-1229.01
Expiration Date: 09/13/16
Coin Approval Date: 04/05/12
Page 7 of 8
13. Questions.in regards to the application of Polyglass products should be directed to our Technical Services
Department at l (800)894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association(NBCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
0000..
0000..
•..... • •
0000••
0000 • • • •
0 0 00.0.•
0000 • 0000•
•..••. •• • 0000•
•• •• •• •0.0•.
•
0000•• • •
• • . 0
• • ±0.00•
0 .
• •
NOA No.: 11-1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
APPrOVED1Page 8 of 8