Loading...
RF-15-3121 Inspection Worksheet z Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-249535 Permit Number: RF-12-15-3121 Scheduled Inspection Date: February 24,2016 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: OLASO, M CLAUDIA Work Classification: Tile Job Address:55 NE 99 Street Miami Shores,FL Phone Number Parcel Number 1132060131290 Project <NONE> Contractor. FLORIDA E Z REMODELING INC Phone: (305)796-6753 Building Department Comments NEW ROOF FOR ADDITIONAL ONLY Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re-inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid February 23,2016 For Inspections please call: (305)7624949 Page 9 of 40 Lab Report No. 125614 FLORIDA TEC PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY e v C.A.#30448 Lab Certificate#13-0507.02 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO-DADE COUNTY PROTOCOL TAS-106 PROPERTYADDRESs: 55 NE 99th St,Miami Shores PERN17TNo: RF12153121 ROOFING OWNER. SQUARES: 4 CONTRACTOR: Oroni Inc. ROOF pmm..• 3:12 INSPECTOR TILE TYPE.--Spanish"S INrnws: JC ATTACHMENT:• POlyfOam TEsT DATE. 2/11/2016 Testing Equipment: Digital Chatillon DFIS 200 Test Tabulation Required Testing Force:35 lbs No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 1-3 Passed THIS ROOF HAS:PASSED ® FAILED❑THE STATIC UPLIFT IN ACCORDANCE WITH MU MI-DADE COUNTY TAS 106. //, NOT TESTED i , 19' 3 Alberto Cardona,P.E. Lic.No.J708 16' --� 10735 SW 216''St. Unit 416 Tel:305-256-4550 Miami FL 33170 Page 1 of 1 Fax:305-256-6833 www.FloridaTEC.net Miami Shores Village I 10050 N.E.2nd Avenue NE Miami Shores,FL 33138-0000 ` Phone: (305)795-2204 Expiration: 06/21/2016 ry Project Address Parcel Number Applicant 55 NE 99 Street 1132060131290 M CLAUDIA OLASO Miami Shores, FL Block: Lot: Owner Information Address Phone Cell M CLAUDIA OLASO 55 NE 99 ST MIAMI SHORES FL 33138-2338 Contractor(s) Phone Cell Phone FLORIDA E-Z REMODELING INC Valuation: $ 4,200.00 (305)796-6753 ------___ ____....-..__. ... _ s �. _ Total Sq Feet: 400 Type of Work: Available Inspections: Additional Info:NEW ROOF FOR ADDITIONAL ONLY Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $3.00 Invoice# RF-12-15-58090 DBPR Fee $3.75 12/17/2015 Credit Card $50.00 $224.50 DCA Fee $3.75 Education Surcharge $1.00 12/24/2015 Credit Card $224.50 $0.00 Permit Fee-New Roof $250.00 Scanning Fee $9.00 TechnoloyFee $4.00 l Tota -' $274.50 t.f. Gr: r In consid?r7tion of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertainingMereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting8yis permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required fSPELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. .a. OWNERS�'iFFIDAVIT• I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructii�and z g. Futhermore,I authorize the above-named contractor to do the work stated. December 24,2015 r orized Signature:Owner / Applicant / Contractor / Agent Date r-3 Buil�ng Department Copy December 24,2015 1 Miami Shores Village DECi 7 Zo�S Building Department � 11 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 S FBC 20( q BUILDING Master Permit No. Kt"' q-" � PERMIT APPLICATION Sub Permit No. Ey- sI ?A.,, ❑BUILDING ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION E:1 SHOP CONTRACTOR DRAWINGS JOB ADDRESS: �S g115 R Ck City: Miami Shores County: Miami Dade Zip: ?SA3$ Folio/Parcel#. X X- -0-13- 12.80 Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): CAQ&3�al cx OkO-SO Phone#: Address: f>45 W-F— qat sknr -�- City: gtra (i Shags, State: 'V—'L Zip: gs1-M Tenant/Lessee Name: Phone#: Email: `` 1 CONTRACTOR:Company Name: �10i1 Gil9, `E-&7 ReV40d6 /4!1 tMC Phone#:��.,) ��✓`.3 Address: 1005; 5 Lo 4 3 5T , City: M jav*L State:.. Zip: �►�/�.1" Qualifier Name: wec:tb 00tra` cL16.� Phone#: State Certification or Registration#: CCC- 132-tic S Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace„ :, ❑ Demolition Description of Work: Specify color of color thru tile:too,0 Submittal Fee$ Permit Fee_$ ' CO CCF$ �� CO/CC$ Scanning Fee$ C)Q!1 Radon Fee$ DBPR$ 2-'143 Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$��e � /��� TOTAL FEE NOW DUE$ -�'f”° S® (Revised02/24/2014) s Bonding Company's Name(if applicable) Bonding Company's Address ' City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Si nature 4 &,a), Si nature gg OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this sL day of 20 IS- ,by 1-1 day of Dec ewi bey .20 I S .by C�QL'd:n, b G0.S0 ,who is personally known to Ne"t'or C_Arrc*a1'Q who is personally known to me or who has produced lb L-*- c]l\7r NrR_ _ as me or who has produced IDL"* Qn '`r'l It as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: U Sign- Print: Print: e,2 Seal: Seal: ✓�r'' T V*tw " REBECA M.PASTRANA COmffftM IF FFM11 MY COMMISSION 0 EE872624 • . EIS QMmbQf 92x19 EXPIRES:February 07,2017 '�iy �� Boll VIN A8f011Vq APPROVED BYyI/ , Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 2Q 16 details- Business Tax Account FLORIDA E Z REMODELING INC -TaxSys-Mia... Page 1 of 1 9 miamidade.Govt Tare Collector Home Search Reports Shopping Cart Please do not include any special characters in the name,address,and e-mail field such as#,&,hyphens,comma, dashes. We have moved.Our new address Is: 200 NW 2nd Ave,Miami,FL 33128 The information contained herein does not constitute a title search or property ownership. 2015 Tax Bills are Payable on Sunday,November 1,2015. Business Tax Account#6040430 Account details . _,Account history 2016 2015 2014 2013 ... 2010 PAID PAID PAID PAID PAID Account number: 6040430 Owner(s): FLORIDA E Z REMODELING INC Business start date: 05/01/2007 10051 SW 43 ST Business address: FLORIDA E Z REMODELING INC MIAMI,FL 33165 10051 SW 43 ST Mailing address: FLORIDA E Z REMODELING INC MIAMI,FL 33165 HECTOR J CARRATALA PRES Physical business location: UNIN DADE COUNTY 10051 SW 43 ST MIAMI,FL 33165 Flags: Home Business Print account application {PDF} PAID 2015-09-26$75.00 Contracting 10/01/2015 NAICS code: Receipt#CREDITCARD-15-049784 C11 Print GENERAL BUILDING —09/30/2016 2389 this bili CONTRACTOR Units:1 Documentation Required by Occupation: State/County License or Certificate Document Received: CCC1328085 https://www.miamidade.county-taxes.com/public/business tax/accounts/6040430 12/17/2015 CERTIFICATE LIABILITY INSURANCE DUPUIS= pnowim UN{WM IMM MM UMM AS A M A176t OF 01FDNSAATON AAD ALL-L=ES INS ASSOC INC ONLY AND COMM SO MMM UPON TM CWVWATE 58{10 SW 135 Ave Ste 106 i! •TM CATS O NOT'AMS,0f1NND OR Kiami, IPL 33183 NBAFFOROM C4VEitA1 NIAICS ° 12AMIDA E-I itNODELIW6, INC. *=xtmk 10051 S.W. 43 ST. wsurac . HUM, EL 33165 z TH H OR CION OF ANY Cts mokcT OR OTMR DOCi mff WRN f�B W TO Y 144"a Cf3 a"WAM MAY Ss OR MM �W IM POLt=OE �S MMaTO A"TM U MS.MLUSNSNS NO COMMOMOF WCN wmELB fMAYMVWRETaE!!RE LIMBYPMCtAM ughom LdAKM EACH Y�mmew neIOaiI.M. ---- 15-0187 09/18115 09118!18 "Mom 1,000-000AOOPS~GATE 2-000,000 ML L9OT PEPC MMULVMM AMAMD _ ALLOVAMAUM t BatBaa�AtJTM nifR" MM Now BOOLYOM;w NON4YOMAMS mmmovoo _ PROPEMOAMAM f L619Lt/Y AWAWO dTHBlRTiUN Auf oon�YAM I LYI�AlTY EACH 221EMMM r�rnrr rrrr 0=0 ❑CAOMMAGE ASGREGM woompsoomp TMNAND auftoYERS'LLMMJTN ••„„„ „„ AEY www BL.EACH baFtCHlMPwt B�.flGlOt OTHM 11ON�Oi�aATHCISt1:0OATiDHB/VENIGFBJ OBYE JSAErditl. & Rt1OrM COWMAsCTOR CITY OF mimes SNOP49S sfioLLnANYof T�ABa�re Pa res BE e�wawN stri xm DEBAR DATE THEMOF,TQM MMus INSURER WLL DAYS WMfryM 10050 HE 2ND AV== NWOMTOTMCENTIPtCATEMOLMNAMED THEWT.BHHTP CTO-00MMALL OR �' SHOMS, 9'L 33138 X 118 ofLtf;ATfav oa rrfp AORM ftx (305} 756-8972 ACOMUPM)j RAC4� ORAT M988 Aft ,iii AtMgtty9p CHW IPMANCIAL OWNWR STATE OF FLORIDA DEPARTtMENT OF FINANCIAL SERVICES DMSION OF WORKERS'COMPENSATION '•CERTIFICATE OF ELECTION TO BE EXEAWT FROM FLORIDA WC$tKFJMI COWMNSATiON LAW•, CONSTRUCTION INDUSTRY EXEMPTION Ttuss cWtOw that the indN dwt listed below has OkKAOd to be exec rV from Florida ftykem'Compensabon low. EFFECTIVE DATE: 7118=15 EXPIRAT I DATE: 71151.2017 PERSON: CARRATALA HECTOR FEN: 201226350 BUSHOEW14AW AND ADDRESS. FLORIDA E Z REMODELING INC 10051.9W-43 ST M AN FL 83165 SCOPES OF BUSINIM OR TRADE: LICENSED GENERAL LICENSED ROOFING CONTRACTOR CONTRACTOR PtuauWd 4Sty.{t5llaj S.ara a oT a exanvdm tcatn triis doov by+;;�s c4r to of low -AS sez�nNin *�r or smarm _ m A40�QX4(72}.F.3.. a d efes8o^t hi keel..aper onto wQtth dos sWP of ftar Of is d On ft nub=OUciton lobe skan4d.FhrWArd to Chi 4ft0 j%F,S,kdms d n w be esempf aed MWAsm al dwsm to toMOW 00 be in mvamum W.m any*m dker ft s"of ft noon ar ft brAKM doe cWtIfteft. me pmt p rotobed as on"aft*or cwtftw fm#Dtw" bre requmnerm w to wman far WOUrAW Ofa ate.The aeperUMM OW make a DFS�F2,DVYC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 0&13 OUESTIONS?t8W}41306W FLORIDA - E ELING INC` ROOFING AND GENERAL CONTRACTOR 10051 SW 43th ST MIAMI FL 33165 PHONE (305)796-6753 ENJAL: HECTORI910YAHOO.COM Date:Dee-,m6e r 1-1, 210 LS State of r—L- County of-_K u►►M:- bad e Before mi this day personally appeared r"I( r ,rral \a who, being duly swom,deposes and say: That he will be the only person on the project working at e t%le C1°I S-r SWEto(affirmed)and subscribed More me this qday of rwern be., ,20_!5 by Personally Know OR Produced Identification O n fl 4e Type of Identification Produced L .,; $*P T.Vasquez COMMUm # FF9011 .•r Vis:DWft 9,2019 WW thru Aaron NotaryPrin Or a of tary STATE LICENSE CCC-1328085 STATE LICENSE CGC-058612 4 Eggs CU Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner— Workers' Compensation Insurance Exernption 211-11 , 011- W, Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers'Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees,including the owner,must obtain workers'compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if 1. The officer owns at least 10 percent of the stock of the corporation,or in the case of an LLC,a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State,Division of Corporations;and 3. The corporation is registered and listed as active with the Florida Department of State,Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers'compensation exemption and has acknowledge that he or she will not use day labor,part-time employees or subcontractors for your project.The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project.In these circumstances,Miami Shores Village does not require verification of workers'compensation insurance coverage from the contractor's company for day labor,part-time employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Signature: a"Op, Owner State of Florida County of Miami-Dade The foregoing was acknowledge before me this day of J?�l 20 %_5 By who is personally known to me or has produced L„ as identification. Notary: SEAL: RE13ECAR PASTRANA My COMMISSION 9124 L ap OMES.Fvbkn�-�y 07.2X017 `5 L' Miami Shores village Wes 4n. Building Department °2 10050 N.E.2nd Avenue �lpR�pA Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: M2 2- 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: K Cka 'fa taco Property Address: 55 1AE 9q 5I Roofing Permit Number.if-12-15.3121 Dear Building Official: I M Gtcw,dia► 0 kQ= certify that I am not required to retrofit the roof to wall connections of my building because: Whe just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 1994 edition of the South Florida Building Code(1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom,deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this 2.3r° day of J)&&wJner So"T.Vasquez Notary Public, Sate of Florida at Large Eou Deomber 9,2019 ,p BonM thru Aaron Notary • when the Just valuation of the structure for purpose of ad valorem n is equal to or more than$300,000.00,and the building was not constricted with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to wall connection Hurricane Mitigation. Revised on 5121/2009 Prope Search Application-Miami-Dade County Page 1 of 1 0. OFFICE OF THE PROPERTY APPRAISER Summary Report Generated On:12/23/2015 Property Information Folio: 11-3206-013-1290 Property Address: 55 NE 99 ST Miami Shores,FL 33138-2338 Owner M CLAUDIA OLASO Mailing Address 55 NE 99 STMIAMI SHORES,FL 33138-2338 Primary Zone 1000 SGL FAMILY-2101-2300 SQ Primary Land Use 0101 RESIDENTIAL-SINGLE FAMILY:1 UNIT ,. Beds/Baths/Half 2/1/0 Floors I v.. y Living Units 1 y Actual Area 1,876 Sq.Ft s=r n Living Area 1,259 Sq.Ft ; Adjusted Area 1,504 Sq.Ft Taxable Value Information Lot Size 8,625 Sq.Ft 2015 2013 Year Built 1938 2014 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2015 2014 2013 Taxable Value 1 $66,005 $65,085 $63,385 Land Value $164,082 $164,082 $112,453 School Board Building Value $107,588 $105,693 $106,579 Exemption Value $25,000 $25,000 $25,000 XF Value $1,711 $1,729 $1,746 Taxable Value $91,005 $90,085 $88,385 city Market Value 1 $273,381 $271,504 $220,778 Assessed Value $116,005 $115,085 $113,385 Exemption Value $50,000 $50,000 $50,000 Taxable Value $66,0051 $63,385 Benefits Information Regional Benefit Type 2015 2014 2013 1 Exemption Value 1 $50,000 $50,000 $50,000 Save Our Homes Assessment Taxable Value $66,005 $65,085 $63,385 Cap Reduction $157,376 $156,419 $107,393 Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Exemption $25,000 $25, ,000 Previous Sale Price OR Book-Page Qualification Description Homestead 000 $2510/01/1995 $84,000 16950-2574 Sales which are qualified Note:Not all benefits are applicable to all Taxable Values(i.e.County, 12/01/1986 $62,000 13125-2303 Sales which are qualified School Board,City,Regional). 12/01/1973 $43,500 00000-00000 Sales which are qualified Short Legal Description 08/01/1973 1 $32,000 00000-00000 1 Sates which are qualified MIAMI SHORES SEC 1 AMD PB 10-70 LOT 18&E1/2 OF 17 BLK 9 LOT SIZE 75.000 X 115 OR 16950-2574 1095 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: http://www.miamidade.gov/propertysearch/ 12/23/2015 .=* I I • ' • • Z � � • � • • ■ • • • ■ • • ■ • ; Z7 -1. ■WIrlLWCi buvmciwWrw=wC=CCW:.iir■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ iiiii■■E■■mm■■11■■■mm■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■E■■■■■■ mqLI■■■■'.1,n■■■11■■Cr7.�11i.i.=..■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ • UNEIM■■■UMN-0–R1!ww=== Groni■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ilii■■■■■mm■■11■■■■■■MM■119E■MM■M■■MMMM■■M■■■■■■MM■■MMMMMM■■■■ ILoa>1■■■I/Ilit��rw.■..r. Suitt■N■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ilii■■■■■11■IFIL■LI■/1 %till�lt1■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ 111�!��l�f.flR.Tl<!,iii�'I li SQL 13i~4�M INC■MPETMEwwww ■■ 1■■ VViiWiilN■O■■■■■Eli■■----1■11■■I■►�■■■■■■■■!■■ •• • - 1■■ ■■■■!.!!�r�1.1R��'�"�t�iin��T:�?■■I■11■l<i■�III■■■■■■■■■■■■■■■■■■■■■■■■■>z■r■■ �il!L9�lilli�'iiiliiiW'Iiiirirrrrrr.._•^�:�J■■rLw■■■�l�■■■■■■■■■■■■■■■■■■■■■■■■■ w��■■.■■t:�n■■■■■�►1■■yin■r.►�■■■■i■■�■■■■■■■■■■■■■■■■■■■■■■■■■■ ._t Y■f■■y�Gl�%■I■■■/I■■/I\`�I//■Li■I■/■CC�C:7■1'�������������■■■■■■■ ■■■■■■■■■■■■■I■■■11�7\i/I■/./■I■��■!■■■■■1 • • - NOON■■■ ■■■■■■■■■■■■1%■■■■�%■I■/�■I■/�■II■■■■■1 NOME l ■fi■/./■%■/I■I%O/J■NOON■■M■■■M■ON■M!�■�!!�ltll�!!� Mow, OWMISNP.11P ■■■■■M■■■■EMM■■■■■■■■■■■■mow.■■■■■■■■■■■■■■M■■■■,�;■->. .�■■`�■■�;w ■■■■■■■■■■■■■■■■■■■■■■■■■■t■■■■NOON■L■■t■t■■■t/n!��■mow■)!�■1■� 'zl Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Santafe Tile Corporation Product Approval Number: 12-0210.01 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): P1: 47.6 p2: 100.6 p3: 100.6 ...... Maximum Design Pressure � �.� ....�. Product Approval Specific System: 45.5 .. .. ...... . .. ...... Method of Tile Attachment: 3M 2-COMPONENT FOAM ROOF TILE AS-160 ';;;;' •••• ....% .... . ..... ...... ... . ..... .. .. .. ...... Steep Sloped System Description ; ; Deck Type: 15/8 INCH PLYWOOD 6556 Roof Slope: Type Underlayment: ASTM D 226 TYPE 11 #30 4 : 12 Insulation: N/A Fire Barrier: N/A Fastener Type&Spacing: Ridge Ventilation? 1 1/4" R.S.CORROSION RESISTANT CONTINUOUS Adhesive Type: F3M 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160 Type Cap Sheet: --- POLYGLASS POLYSTICK(PEEL AND STICK) Roof Covering: Mean Roof Height: 13' 1 SANTA FE CLAY ROOF TILE(COLOR THRU) Type&Size Drips Edge: 3 INCH 26 GAUGE Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mrwiththe values from Mt.If the Mr values are greater than or equal to the M, values,for each area of the roof,then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P,• 47.6 X .297 - 14.14 )-Mg: 5.69 =Mrt 8.45 Product Approval K-61.9 (P2; 100.6 XX 297 a 29�-Mg: 5.69 c Mr2 24.19 Product Approval Mt 61.9 (P3: 100.6 XX .297 = 29.88 )-Mg: 5.69 a Mrs 24.19 Product Approval Mt 61.9 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance(Mr)From Table Below Product Approval Mt M R wired Moment Resistance* Mean Roof Height--lo. Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 4 3:12 32.2 34.4 36.0 37.4 9.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 300" 32.4 7:12 24A 25.9 1 27.1 8.2 30.0 *Must be in onlunc tion with a list/culations based tits systems a orsed by the Broward u Boistems Rules and Ap For Upli based use Meompare the lues for F'with the values for Fr.if the 'values reater than oo the Fr v es,for each area of the roof,then the tile a achmenhod is accep Method 3"Uplift culations Per AS 12(P,: x 1: = x w:= - s& - =Fr, Product roval F'(P2: x 1: = x w:= - os 0: - =F vat F' (P3: x 1: = x w:= )- os& - Fra Product Appro F' Were to Obtain I formation Description Sym 1 Where to find Design Pressure Pt r P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof SI 9 Job Site Aerodynamic Mui ler A Product Approval Restoring Moment due toravity Ma Product Approval Attachment esistance M, Product Approval Required Mompf Resistance M, Calculated Minimum Attac ent Resistance P Product Approval RequWd Uplift Resistance F, Calculated Average Ills Weight W Product Approval lite DimensionsI'.length Product Approval W-width l calculations must be submitted to the Building Official at the time of permit application. 9 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING ' CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initial in the adjacent box indicates that the item has been explained. _Pe6 -1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics (appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. P C.0 2.Renailing Wood Decks:When replacing roofing,the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403.(The roof deck is usually conce a4or to removing the existing roof system.) . . ...... 4k CL 3. Common Roofs: Common roofs are those which have no visible*88V8atioAetween ••••:• neighboring units (i.e. townhouses, condominiums, etc.) In buildings with commed Ifts, the roofing �•.•.� contractor and/or owner should notify the occupants of adjacent units of roofing wor fe&perfor . ����• e 4.Exposed Ceilings: Exposed,open beam ceilings are where the underside:ofICe roof;eek. .....' can be viewed from below.The owner may wish to maintain the architectural appearance0t6refore,roofing nail penetrations of the underside of the decking may not be acceptable.This provides t 000600 tof m intai in • aT g • this appearance. •••••• . . above• 5. Ponding Water:The current roof system and/or deck of the building may not drain%gl?add may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. . Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402,R4403 and R4413. _J C&�7.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Exception:Attic spaces,designed by a Florida licensed engineer or registered architect to eliminate the attic venting,venting shall not be required. 5 Owner's/Agent's Signature Date 4Contrto'r`sJSign_ature &5- A1C 99 f 5t/V a. Property Addrps�rS � Permit Number �.i�� � s 33�3� t , , MAMA MIAMI-DADE COUNTY EW PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE_(NOA) www.miamidaae.eoviyera Santafe Tile Corporation 8825 NW Oh Street Medley,FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within*their jurisdiction. PERA reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. . " This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. :...:. DESCRIPTION: Santafe Spanish`S' Clay Roof Tile ...... •. LABELING: Each unit shall bear a permanent label with the manufacturer's name or loo,•0g+J statevanand following'*': statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein!'• 46:906 ...... ... . ..... RENEWAL of this NOA shall be considered after a renewal application has been filed and l erre has beef no chaAA8 in the applicable building code negatively affecting the performance of this product. ,0 00; TERMINATION of this NOA will occur after the expiration date or if there has been a reisiair or changein the:" materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement oitry product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA'is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Oficial. This replaces NOA# 10-1005.15 and consists of pages 1 through S. The submitted documentation was reviewed by Alex Tigera. NOA No.:12-0210.01 Muarranaue CO Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Clay Deck Type: Wood 1. SCOPE This approves a roofing system using Santa Fe"Santafe`S"Clay Roof Tile,as manufactured by Ladrillera Santafe S.A. in Bogota,Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements,as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Santaf6`S' Clay Roof L= 18" TAS 112 One piece high profile clay roof tile equipped with Tile W= 11.1" two nail holes. For nail-on,mortar set and adhesive set applications. Trim Pieces 1=varies TAS 112 Accessory trim,clay roof pieces for use at hips, w=varies rakes,ridges and valley terminations. Manufactured varying thickness for each tile profile. . . :0•"' 000 000 .. . 0 0 0 0 2.1 MANUFACTURING LOCATION 0:99:000 0 0 0 0 0 0•• 0000.. 0000.. 1. Bogota,Colombia •••• • • • • • •••••• 0000 . 00000 2.2 SUBMITTED EVIDENCE 0 0.0 0• 000 0 0000 .. 0000.. Test Agency Test Identifier Test Name/l.2cMcf# Date •0 . . . . 0000.. The Center for Applied Engineering,Inc. 94-156-8 TAS 101 0 ... -8g. 19$4 94-156-9 TAS 161-• 0 000 :0000 The Center for Applied Engineering,Inc. 25-7205-1 TAS 101 0•March 1995 The Center for Applied Engineering,Inc. Project:07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix II (Nail-On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102&TAS 102(A) Redland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails CFDApE coe�rrrNOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 2 of 5 2.2 SUBM=D EVIDENCE Test Agency Test Identifier Test Name/Renort Date Redland Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) Redland Technologies P 0631-01 PA 108 July. 1994 ,(Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 113A Consultants,Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies,Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants,Inc. 2353-70 TAS 101 09/22/03 IBA Consultants,Inc. 2353-71 TAS 101 09/22/03 IBA Consultants,Inc. 2353-93 ASTM C 1167 07/18/05 3. LDmATIONs 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofin A !cadonsOStanOdards Usled. Y P � pp � pl'i-. section 4.1 herein. •• • •• • 3.5 30/90 hot mopped underlayment applications may be installed perpendiculaf'4b'MVroof sYop8 finless St'hfed' otherwise by the underlayment material manufacturers published literature. 600606 :•••• 3.6 This acceptance is for wood deck applications. Minimum deck requiremenft,S44H be ir:Lafnpliance Vrj#L applicable building code. 000000 0 0 0 3.7 May be installed on slopes 7:12 and greater. 000000 0•: 6000:0 6....• 0 00 4. INSTALLATION 0 0 0 0 0 0 0 0 6 0 6666.. 4.1 Santafe 'S' and its components shall be installed in strict compliance with RUbfiffg ApUffc$tt4n Standard• RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W)and Dimensions(I x W) Tile Profile Weight W(lbf) Length-1 (ft) Width-w(ft) Santafe'S' 6.7 1.5 0.958 NOA No.: 12-0210.01 Expiration Date: 02/61/16' JAPPROVED!_,i Approval Date: 05/31/12 Page 3 of 5 Table 2: Aerodynamic Multiplyers-.X(te) Tile -%(ft ) A,(ft) Profile Batten Application Direct Deck Santafe'S' 0.274 0.297 Table 3: Restoring Moments due to Gravity-Mg(ft-lbf) Tile 2"•12" 3"•12" 4':12" 5"12" 6"•12" 7"•12"or Profile greater Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck I Deck Santafe'S' 5.93 1 5.90 5.85 5.82 5.73 5.69 5.56 1 5.53 5.32 5.29 5.03 1 5.00 Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-ibf) for Nail-On Systems Tile Profile Fastener Type Direct Deck Battens Santafe'S' 2-10d Ring Shank Nails 21.8 N/A One#8 Screw 29.16 N/A Two#8 Screws 38.28 N/A One#8 Screw w/Clip 57.31 N/A Two#8 Screws w/Clip 57.60 61.77 __l 1. Approved screws as noted'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment off(ft j ;•bf) •••• **0 00* for Two Patty Adhesive Set Systems '..' . • . • Tile Tile Application �j"M n(m u m7 A achmen ProfileRes to ce •••• • Santafe'S' Tile Bond '... ' 8 •• .... Polyfoam PolyproAH 160TA° 0000.0 2&64 . ..:. ' 2 See manufactures component approval for installation requirements. •. .. •.. 0 0 0• . 3 Flexible Product,Inc.Average weight per patty 10.4 grams. . . 4 Polyfoarn Product,Inc.Average weight pera 9.4 grams. ' ' • •0000• Table 6A: Attachment Resistance Expressed as a Moment-Mt(ftNbf) • for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Santafe'S' Polyfoam Polypro AH 160Tm 63.8 Pol oam Pol ro AH 160T"' 61.9 5 Paddyplacement of 63 rams of Pol ro AH 160TM. 6 Paddy placement of 24 grams of Polypro AH 160Tm. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Attachment Profile Application Resistance Santafe'S' Mortar Set 23.6 NOA No,:12-0210.01 JAPPROVEMwr7Nntwe cD! r Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami-Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH"S"CLAY ROOF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING When using one screw use-this hole. 18" . . • ...... . .. ...... ••9.9• • 6666 •666•• • 6 • • 6 6090 • 90.00 06.00• 009 • 00090 •• •• •• •096•• • •9•••• 0 0 • • • • • • • 0009000 •9009• 00 • • • •• • 11.1" "SANTAFb`S"CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 12-0210.01 raecout�nr Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 5 of 5 + J MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN.55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2-Component Foam Roof Tile Adhesive AH-160 0000.. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logq a cty, sitp and following' statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein..... : 0 0 00 0 0.0:0 900.0. 9 0000.. RENEWAL of this NOA shall be considered after a renewal application has been filed Vd thgre hag Mpg no chhnge • in the applicable building code negatively affecting the performance of this product. 0000 999999 TERMINATION of this NOA will occur after the expiration date or if there has bees i.revj'sion or change in thg' materials,use,and/or manufacture of the product or process. Misuse of this NOA as an en4orstdent of a�n�iprod=4 ofof: sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comRly wig lany sectio p f this NOA shall be cause for termination and removal of NOA. 0• 0 0• :0: • 99 9 ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 a ;COUId7 Y Expiration Date: 05/10/17 Approval Date:09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in this Notice of Acceptance. For the locations where the design pressure requirements,as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using 2-Component Foam Roof Tile Adhesive AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3Mrm 2-Component N/A TAS 101 Two component polyurethane foam adhesive Foam Roof Tile Adhesive AH-160 Foam Dispenser N/A Dispensing Equipment RTF1000 ProPack®30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOAr whichrist t attachmen •;• resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof the g&hesfve. •. ...... . .. ...... MANUFACTURING LOCATION: 0::::o ••"" 1. Tomball,TX. 0000 0000 .. 0000.. PHYSICAL PROPERTIES: 0000.. • Property Test Results •••••• Density ASTM D 1622 1.6 lbs./fft.3 ••• ••• • Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Fe Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @1587., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.:14-0805.01 Mn�4oecauNnr Expiration Date: 05/10/17 Approval Date:09/04/14 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 ;olOY28/98 .9•.. 520109-2 • 00 520109-3 • ' 520109-6 520109-7 •••• • 520191-1 TAS 101 "" '03/02/99 • 520109-2-1 ••�•'� •�•• �•��� .. .. .. ...... LIMITATIONS: • • . . . . ...... 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Asse%bry for fire tatial. 2. 3Mm 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tiTe profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3M7 2-Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 14-0805.01 APPROVED Coin Expiration Date: 05/10/17 Approval Date:09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A"component and the"B"component shall be maintained between 1.0-1.15(A): 1.0 (B)• 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or ProPackO 30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight s%jga qin accordance with the'Placement Details'herein. Each generic tile profile requires the spgooc placement noted•••:• herein. •• • :09 go • .09.40 9 .. ...... ...... 494099 :9:: 9 • • r • r 9:r99 r::: r r99:0: r • 9::r:: 099 r 090.0 09 r9 00 r4r:r: • •90:09 9 • 9 9 4 9 99::09 r4r::9 • • • • 0 • r • :4:99: go 0 MAWDADE_ NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date:09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low,High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved"or the Miami- Dade County Product Control Seal as shown below. MlAM 1 BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. .006.0 0000.. .. % 0000.. 0000.. 0000 0000.. 0000 . 0000. 0000 .. 0000.. 0000.. 0000.. . . 0000.. .. 0000 NOA No.: 14-0805.01 . ;ED L Expiration Date: 05/10/17 Approval Date:09/04/14 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# 1 Flat/Low Profile Tile 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. ° 2. Continue in same manner. Insure approximately 17 (109.7 cm)—23 (148.4 cm)square inch adhesive contact with the underside of the tile. Medium Profile/ Double Pan Tile d 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 10 R16 i 2. Continue in same manner.Insure approximately 17 (109.7 cm)—23 (148.4 cm)square inch adhesive contact with the underside of the tile. ,1le High Profile/Single Pan Tile 1. Starting at the eave course,apply a.minimum 2" 4s (50.8 mm)x 10"(254 provi I"(2,V min)foam••:- paddy onto the underlayThent posifted gs shown• SO es under the pan portion U W the cldsest to the Overlock of the the being �t •• ••••; 00090 :**Goo 2. Continue in same manmi,.lnsure approximately.Z.' ° . (109.7 cm)—23 (148 Aocni5 square in*o4adhesive•:• contact with the under=8f the tile. . • b . . i...% ....i. . . ...... NOA No.: 14-0805.01 ran�Fcouwn Expiration Date: 05/10/17 Approval Date:09/04/14 Page 6 of 11 ADHESIVE PLACEMENT DETAIL#2 Flat/Low Profile Tile • 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17(109.7 cm) 23 (148.4 cm2)square inch adhesive contact with the EM underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) Palm x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm)- 12 (77.4 cm2)square inch adhesive contact with the underside of the tile. Medium Profile/Double Pan Tile $ 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. Insure approximately 17(109.7 cm2)— '�` 2M. 23 (148.4 cm)square inch adhesive contact with the underside of the tile. i 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overl"a£the tile Pods 0 000000 being set. • 3. Continue in same mannes,ehAxse approximately 12" .00000 (77.4 cmm 2)- 14(90.3 c � re ini*ogA sive • • contact with the undersideV t'he tile.• ••;••. .0.0.. 0 • (Instructions continued on�iekt'ppge) • 0000.. 0000.. .. 0000 V*to: NOA No.: 14-0805.01 MW4M DFc?LWM Expiration Date: 05/10/17 Approval Date:09/04/14 Page 7 of 11 ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) High Profile/Single Pan Tile 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17(109.7 cm2)— '�' hL 23 (148.4 cm)square inch adhesive contact with the underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan t a portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 17" (109.7 cm)- 19(122.6 cm2)square inch adhesive contact with the underside of the tile. ...... . .. ...... .... . 09.6. ...... 000 . 69604 .. .. .. 0.00•9 • • • • •9966• •0090• • • • •9996• NOA No.: 14-0805.01 tl4DECOUNr�r Expiration Date: 05/10/17 Approval Date:09/04/14 Page 8 of 11 ADHESIVE PLACEMENT DETAIL#3 1. On the eave course only,apply a minimum 2" (50.8 ® mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown,under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest aahL ' �, to the overlock of the tile being set.Leave approximately 4" (10 1.6 mm)up from the eave edge free of foam to prevent the expanded adhesive asap. from blocking the weep holes. Insure • • approximately 17-23 int(109.7-148.4 cm)of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4 - - - -- mm foam add onto the underla ) paddy yment just below fbdAzwFkuMaTJk the second course line positioned foam paddy under the strengthening rib for flat tile,or under the pan portion of the tile,closest to the underlock for the second course tile to be installed. Insure OMdfftft approximately 8-9 int(51.6-58.1 cm2)of adhesive contact with the underside of the tile. w, (Instructions continued on next page) * sada; =4�. 2�. •••••• • •• •••••• • •••• • ••••• •••••• ••• • ••••• •• •• •• •••••• • • • • •14M •••••• NOA No.: 14-0805.01 O��ueCouPrrY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x'/4" (19 mm)paddy on top of the eave course rile y surface as shown,on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of rile. Install second course of tile.Insure approximately 9(58.1 cm2)- 11 (71cm2)square inch adhesive contact with the underside of the file at the overlap and 7(45.2 cm2)-9(58.1 cm2)square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. WaWhok dome High PmMolft ...... . .. ...... .... . ..... ...... ... . ..... ...... . . . . ...... .. . ... NOA No.: 14-0805.01 !APPROVED Expiration Date: 05/10/17 Approval Date:09/04/14 Page 10 of 11 s ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile p1. Starting at the eave course,apply a minimum 2" tyre �aar� ss�rasy.�n. t ►�� 1 , y (50.8 mm)x 0 (254 mm)x 1„(25.4 mm)foam at + ►. e to paddy onto the underlayment positioned as a►s�r. � crx an adjacent d shown under two atiles. a� es�a► J p Support eave Sb{n. a. tiles from rocking until adhesive has a chance to ., cure. ° a • 2. Continue in same manner bringing two pan � courses up toward the ridge.Insure approximately 65 (419.4 cm)—70(451.6 cm) square inch adhesive contact with the underside of the pan tile. tn+ ref 3. Turn covers upside down exposing the underside of the tile.Apply a minimum 1”(25.4 mm)x 10" (254 mm)bead of adhesive directly on the inner +aeeaseceae•nwtea edge of each side of the cover tile.Leave approximately 3/4"(19 mm)to 1"(25.4 mm) Two 8ar*1_High Profile Tile from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20(129 cm) -25 (161.3 cm)square inch contact area on each side of the c.overtile to the pan tile. Continue in same manner.*'t`M away*•••• any cured exposed foam adhesivr.Fd4ting of •, longitudinal edges 6M&Ubver tiles We considered optional. ::: . •••• . ...... .... . ..... 5. When additional nail' ie requiwd,2':(50.8..:..' mm)x 4"(101.6 mm6ilers or the tie+wire •••••• system using galva*f,'4ainless steel,or •, copper wire and colpatibre naill a4 be use'cr END OF THIS ACCEPTANCE NOA No.: 14-0805.01 M!APPR;EDI Expiration Date: 05/10/17 Approval Date:09/04/14 Page 11 of 11 ' r INIAMI�� , MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DMSION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/sera Polyglass USA Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there hass&no change in the applicable building code negatively affecting the performance of this prodiQt• ; • ...... . .. ...... TERMINATION of this NOA will occur after the expiration date or if there has been a-rmsinn or change in th;•••• materials,use,and/or manufacture of the product or process.Misuse of this NOA as an w1dd&rnen"a4);prodAct, for sales,advertising or any other purposes shall automatically terminate this NOA. FailVZe;*o jomplywith any :::**. section of this NOA shall be cause for termination and removal of NOA. • .. .. .. ...... ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,*-Florida, anlijifVred bythe:• expiration date may be displayed in advertising literature. If any portion of the NOA:s dilplayed', then it sha=t.be.: done in its entirety. •' .*•:• : • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 11-0601.10 and consists of pages 1 through 8 The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-1229.01 Expiration Date: 09/13/16 MIAMFDADE CO: Approval Date: 04/05/12 iAPPROVEDI Page 1 of 8 e I ROOFING COIVIP0NENT APPROVAL Category Roofing Sub-Category: Underlayment Material: SBS ,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt underlayment 65'8"x 3933/8" waterproofing membrane,glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing,roof tile, slate tiles and shingle underlayment. Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering, underlayment 65' x 3'3j/8" ASTM D 1970 APP polymer modified,fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 &#2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice&rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP underlayment 32'10'9 x 3'3j/8" ASTM D 1970 polymer modified,fiberglass or polyester Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as #1 &#2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering,glass- underlayment 65' x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal r4Qfiug and roof Manufacturing Location tile underlayment. .. F. 0 0 . #2 0000.. .. .0000. 0000.. 0000.. Polystick TU P Roll: TAS 103 and A rubberized asphalt j ate..rproofiggmembrane, 0000. underlayment 32'10"x 3'3j/8" ASTM D 1970 glass-fiber/polyester r4agWed,vtiib a granul#4;. • Manufacturing Location 130 mils thick surface designed for use as a tile roof #2 underlayment. •••••• • 0000.. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-Aheringr glass- :"'0 Manufacturing Location 61 x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterprdtlf ng #2 60 mils thick membrane.Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61' x 3'3j/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11-1229.01 Expiration Date: 09/13/16 MIAM4DADE COUNTY ... , Approval Date: 04/05/12 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton,PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Azency Test Identifier Test Name/Renort Date Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09 Momentum Technologies,Inc. JX20H7A TAS 103/ASTM D4798&G155 04/01/08 RX14E8A TAS 103/ASTM D4798 &G155 11/09/09 DX23138B TAS 103/ASTM D4798 &G155 02/18/10 DX23D8A TAS 103/ASTM D4798 &G155 02418/10 •••••• • •• •••••• • •••• • ••••• •••••• ••• • ••••• •• •• •• •••••• • •••••• • • • • • • •••••• NOA No.: 11-1229.01 Expiration Date: 09/13/16 Muvra naa�counrr�r AVEDI_ pproval Date: 04/05/12 JAPPRPage 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6"o.c. at a minimum 4"head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-%2"and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. .000.0 4 00 4 .0 0 . . 0 0000.. . .. 000900 0000.. 0000 000000 0000.. 0000 . 00000 040000 •00 . 00000 40 40 40 .40000 44404• . 4 .4400.• 0*00:0 0 4 0 . . 0000.. 00 0 0 000 0 4 NOA No.: 11-1229.01 Mu►Mana�co Expiration Date: 09/13/16 ... EDI Approval Date: 04/05/12 Page 4 of 8 GENERAL LvvmATIONS: 1. Fire classificatidn is not part of this acceptance. 2. Polystick MTS,TU Plus,Tile Pro and Dual Pro may be used in asphaltic shingles,wood shakes and shingles, non-structural metal roofing,roof tile systems and quarry slate roof assemblies. IR-Xe,TU,and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. Expos re Limitations(days) MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven FL. 180 180 180 180 180 180 180 Hazelton,PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance.Polystick TU,TU Plus,and Tile Pro may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe,and Dual Pro are limited to mechanically fastened roof tile applications.Polystick MTS is limited to mechanically fastened with battens roof tile applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Poly:tick • ,•T •�••• Plus,"W P,Tale Pro . . .• ...... . .. so**:* Flat Tile Prohibited without battens 5:12 •°'R8-limitation ;,,,„ Profiled Tile 1 Prohibited without battens Prohibited .'�blimitaan.:. The above slope limitations can be exceeded only by using battens and counter bad81914 accofft4with Qin••• Approved Tile System Notice of Acceptance and applicable Florida Building Cod •• •• ements. attens••• • are required for both loading and installation of tiles at all times. ; • , •,.•;• 00 • • NOA No.: 11-1229.01 Expiration Date: 09/13/16 MIA UHIXI COUNTY Approval Date: 04/05/12 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. z Roofing Tiles " (6 Max Per Stack) 2 12 06 a r O g N l y � � t 'F i 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 969.6. 6 6666.. LABELING: 0660 : .. .• 1. All membranes or packaging shall bear the imprint or identifiable marking of the > turer=s nj*me or 100,6 city and state of manufacturing facility and the following statement: "Miami-Dade.County grodgct Corp— •; Approved"or the Miami-Dade County Product Control Seal as shown below. 0.6 600V0000 6 6 9.6 00.00.• 690 6 99.06 MO MI-DADE COUNTY .6 6. 00 6 6 9 6 9 6 6.96.. • • • • 6 • 096696 BUILDING PERMIT REQUIREMENTS: 00*00 0.... .. . . .96 Application for building permit shall be accompanied by copies of the following: •9 0 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11-1229.01 Expiration Date: 09/13/16 !APPMIAMFDAROVED I TY Approval Date: 04/05/12 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1"metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251 Premium Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic,applied in between the application of the lap.The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the tile manufacturers NOA's,must be used on all projects for pitch/slopes of 7712"or greater. It is suggested that on pitch/slopes in excess of 6 '/a"/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. .00000 8. Polystick membranes may not be used in any exposed application such as crickets;exp8sed valleys,or •••••• exposed roof to wall details. 0:009: •••. ••• • 9. Repair of Polystick membranes is to be accomplished by applying Polyglass PolypilLI; 15*PremiumModifiad • Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass M300 MS Flaking Cement,Mule-Hide 241 Premium Modified Flashing Cement,Mule-Hide 251 Prel".Wet/ISry Elastom�rwa Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mag?r.td the area%deed qf.•••• repair,followed by a patch of the Polystick material of like kind should be set an(t1i dolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches i'n either dir ,q ,The •••••• repair should be installed in such a way so that water will run parallel to or over tle pop of all ta•p hof the patch. • • • 00 0 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request.It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 11-1229.01 Expiration Date: 09/13/16 Coin Approval Date: 04/05/12 Page 7 of 8 13. Questions.in regards to the application of Polyglass products should be directed to our Technical Services Department at l (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NBCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE 0000.. 0000.. •..... • • 0000•• 0000 • • • • 0 0 00.0.• 0000 • 0000• •..••. •• • 0000• •• •• •• •0.0•. • 0000•• • • • • . 0 • • ±0.00• 0 . • • NOA No.: 11-1229.01 Expiration Date: 09/13/16 Approval Date: 04/05/12 APPrOVED1Page 8 of 8