FW-16-1544 f
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores,FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-260273 Permit Number: FW-6-16-1544
Scheduled Inspection Date:July 08,2016 Permit Type: FenceMall
Inspector: Porta Jr,Jose
Inspection Type: Final
Owner PUENTES,ANDRES Work Classification: Wood Fence
Job Address:354 NE 91 Street
Miami Shores, FL 33138-3130 Phone Number (786)606-9930
Parcel Number 1132060190220
Project: <NONE>
Contractor: SAMADA FENCE INC Phone: (305)720-6344
Building Department Comments
HORIZONTAL PICKET WOOD FENCE 5"HIGH Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed ri ,
Failed
Correction
Needed
Re-inspection
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
July 07,2016 For Inspections please call: (305)7624949 Page 10 of 32
Miami Shores Village
10050 N.E.2nd Avenue NE
_ .
Miami Shores,FL 3313&0000 ��'
r..
� Phone: (305)795-2204
Expiration: 12/12l2016
Project Address Parcel Number Applicant
354 NE 91 Street 1132060190220
ANDRES PUENTES
Miami Shores, FL 33138-3130 Block: Lot:
Owner information Address Phone Cell
ANDRES PUENTES 354 NE 91 Street (786)606-9930
MIAMI SHORES FL 33138-
354 NE 91 Street
MIAMI SHORES FL 33138-
Contractor(s) Phone Cell Phone Valuation: $ 1,750.00
SAMADA FENCE INC (305)720-6344 Total Sq Feet: 47
Approved: Available inspections:
Comments: Inspection Type:
Date Approved:: Final
Date Denied: Foundation
Type of Construction:Wood Fence Additional Info:HORIZONTAL PICKET WOOD FENC Review Planning
Classification:Residential Scanning:3 Review Building
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $1.20 Invoice# FW-6-16-60041
DBPR Fee $2.00 06/03/2016 Cash $50.00 $66.20
DCA Fee $2.00
Education Surcharge $0.40 06/15/2016 Cash $66.20 $0.00
Permit Fee-Wire&Wood $100.00
Scanning Fee $9.00
Technology Fee $1.60
Total: $116.20
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonin uthermore,I au J the above-named contractor to do the work stated.
x June 15,2016
Autho Signature:OvAer / Applicant / Contractor / Agent Date
Building Department Copy
June 15,2016 1
Miami Shores Village
Building DepartmentSUN ®3 018
10050 N.E.2nd Avenue,Miami Shores,Florida 33138 RY_
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949
FBC 201,-1�
BUILDING Master Permit No. F-w ►� — 1S`l`l
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
d CONTRACTOR DRAWINGS
[/
JOB ADDRESS: 35 T ti K E R I ST 1"d i-ei sl/e- Fe- A3/36
City: Miami Shores County: Miami Dade Zio• 3.3138
Folio/Parcel#: //— 310 0 —0/4? — 02" Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: q FFE:
OWNER:Name(Fee Simple Titleholder): .41yp eu I-f I` ele--4 [ Phone#: 91910-60J6- T fAv
Address:_ 35Y A..-'E Gl/ ST
City: State: L Zip•
Tenant/Lessee Name: Phone#:
Email: p s� �1
CONTRACTOR:Company Name: ynts& 6-w*ie< Phone#: �15���r� �-T�Cr
Address: //0 W va/ 3r
City 1411leA State: F& zip:
Qualifier Name: & Dc9,4A7a41w Phone#: isx--557 - 3tff"
State Certification or Registration M Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ �,SSW• V 0 Square/Linear Footage of Work: Y?
Type of Work: ❑ Addition ❑ Alteration :1 New ❑ Repair/ReplaceElr
� ' Demolition
Description of Work: �'IO/'/ OKITI�L lOI�C/'1 G� �� I�P,�'!c e J fir- �►,�a`r�`
T
Specify color of color thru tile:
Submittal Fee$ "Cj) Permit Fee$ i CCF$ t' 2-0 CO/CC$
Scanning Fee$C) Radon Fee$ DBPR$ Notary$
Technology Fee$ k ,G6 Training/Education Fee$ O Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$
(Revisedo2/24/2014)
• r
Bonding Company's Name(if applicable) ,4AA7AD� �!Cz SME
Bonding Company's Address 6'aw"-A f`Pa'1G� 7A/C &9 W t�I d'T
City /u/�uA State Zip 330/
Mortgage Lender's Name(if applicable) TT
Mortgage Lender's Address Ale '7/r Q
City f l*Wl40 -13� State !r Zip �139
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature,(e� Signature
OWNER or AGENT CON R
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day o '7�- ,20 by day of /!C- ,20 by
who Is personally known to is personally known to
me or who has produced as me or o has produced r a, ;Y as
Identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign Sign
Print Print: W
",..; BAF&MAVIIA .,
Seal WCQMMWION#FF110384 Seal: BARBARAAVIIA
EXPIRES May 18,2018 '° COM(4�5SION FF 110384
tnr�rmrmy aueft u •; eo+odeernroErmyMayn�cl8,2o18
+x�w*�r���•e��e��*ewe.►t��rw�a�as��r **w�+�**a����x�x�a�w�w**w��w*e�*+���*���a�s�a+s***s�*�***wA+►psa�a�+���r�s�xa�x�w�a**�w�*w�ww�r�ra��x�*�ax�*
APPROVED BY L5 I Plans Examiner f 1 lJ /2�`� Zoning
Structural Review Clerk
(Revised02/24/2014)
s
JUN 0 3 tole
�>
SheUFZ or z
o
(V �® o shay
Job Number 512MI18 E 91 Street,�,,11,
<
(70'ftI#-of wey)
T�
..n3h. .t�,yrH.aA•;.•.r• �.. ..a.+K.n��• �';e?w"'.t•wY;'.:"'.°..t.,w' .l�"'.:a? � :d,. '. A'�• :��
•K "+�-..3..,� �''� ;Y.=:k d'::i'. *ti.�: iat, •S.�•p „a' t,,;r,.. r.. aj.
_� :..x.._•` ,'�?!�,M•a..•t.•t .��a„�-L�tj,:..t �y.''��, t`; tp•, ,....s3 � [�
::tt, •;6s�•:.."<.r i•��';y•,•t,f�",�'�,at,.,;, i•y_tt••r•5 ;,t.Fa.;�•rc'";y a:,�:r t�+� i`T�3
•�.X• a• `ts�n•� 2• � /
i.''8j:. .�• P•a(�,`w.• ! . 1�' �•es.s.•,'L�'i:.:Nev i.:`yt+.•�E:s �.iC••'::r�, ,!�.yti y;, �[
ir.•'k vs:e�:ate_.w't,yt.«.tic Y.�'"'1't1�'•9'•��,y..1•t-`•'e•. .:!!•�:..Wa•� �.,•{.�i..«;x�tl: "I :C r.�& :L:
MDnRad� � �
75.00' ,bealdftrAff
� 14;
I
p 4'
I t �0� � •48.f � it � I � (
1 1 O I @�'
)G} 1 y #3MI
3M. I I I
1 6'wmwFer=
i••••i ••i••� �Phue
ftw 8rkk I
•• • I i•i••i I avow EekHO I t
• I
•••••• •• •• •• � Lo$ lotb Lot
••••• i • •j i••iBlp6@2 �� Btca L. Blah2 AW2
a
•••i•• s•e••r •••••• �41'�' J unylift
• • •••• ••••� f b`YYFmdit= 1
• ( 8Y► tine
•
•••••• •••• • •
•
••••� 1a I
F&W V L 2 tat 20 I AOOkwRad I
Abe ? I I
o ,s R4PHI30 so=127W I
Boundary Survey i kwh_ 30 1 I � ►..;
Sc". I kwh fM
fi18 WWRVEY J AFS82E4
8UR1rE1rORS'1r�1ES: S1Q ;•
l.tMEREBY{55R78:f'BAaeavuq+BameAf�arim Tads :, ° i�h_
1�19�rt/Oti4�Bd�m8rehal•1d9+8 8Al8 PRpFE h1
aaatlei9m�lad�Eredsselmeilmfdadawrryormid
FLO/� �
9. pm�xaWobBaead8S
67Msr4msee em A Bteass 4546 WSTRW
t.Ad OnsWai bw+sla m�am+ 6Yo 6ten eatgning WESTFAt7ld8E ma33415
tyorpBtYeskproh ed en �lhes tgpe<fyar WIM 561.O&i764
B.Surraymt +�reaera88onR+ sst�s48air FAX 561.476.104
mwm�trotamrYerassa�a e,e. eameaae PkMIM+uanbwweb awww.PMArveAVa w
e Lwift" cow w4j"aft MW
% .: 'i~ierimntakVicket Wood Fence
. . ... . . . . ...
•. 000 ••• ..
• • •• • • • • • • •• 1"x6"PT n x
PT
... wood pickets wood posts
�typ•
#8d x 2'/"ring
shank nails
J (2)Per post per picket 2 ' 72"
t _
i.-4•.i �• q �n .
3" 10"0 x 24
+i:i t•.Y
2500 psi Conc.
Typical Fence Panels Typical Section
►�``�1� tF iFL JA
No 25221 :•+�` •
Notes' ';;`" •
.t t,
All hardware shall be stainless steel or hot dipped galvankj 0
Dimension lumber shall be ACQ pressure treated and__ ll a'f'ends shall be 2%copper 'J `/' ;'3� STATE O
napthenate treated. :y: T ``; ,,
Concrete shall be 2500 psi at 7 days. = >>`_ ,m:; F�.�.� �•'.�� •`.,1 p 1 t? :'��'�+''
Compact all disturbed soils to 98%standa04: roctor densi .
••....••
Design:2014 FBC&ASCE 7-10oSe $�5.2.1, winds ed 75 mph Qq 115 mph gust, S ,,rsl+�t Alt 's���
exposure C. �~<_t''' William F.Flaherty,P.E.25221
«.,
No changes allowed without written authorization from the engineer. Pompano Beach,Florida 33080
This fence is not designed for use as a balcony rail or other raised structural barrier. Certificate of Authorization#26223
e54-662-9300
Samada 4.6.16