PW-15-3138 Miami Shores Village
10050 N.E.2nd Avenue NE �
3_
Miami Shores,FL 33138-0000 "
Phone: (305)795-2204
Expiration: 4/05/2016
Project Address Parcel Number Applicant
1275 NE 94 Street 1132050100090
JAMES AND JANINE TURK
Miami Shores, FL 33138-2946 Block: Lot:
Owner Information Address Phone Cell
JAMES AND JANINE TURK 2020 N BAYSHORE Drive
MIAMI FL 33137-
2020 N BAYSHORE Drive
MIAMI FL 33137-
Contractor(s) Phone Cell Phone $ 2,600.00
Valuation:
MIAMI DADE WATER&SEWER DEPT (786)256-5200 Total Sq Feet: 4
Scanning:1 Available Inspections:
Inspection Type:
Final
Excavation
Review Building
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $1.90 Invoice# PW-12-15.58109
DBPR Fee $2.00 12/21/2015 Credit Card $111.80 $0.00
DCA Fee $2.00
Education Surcharge $0.80
Permit Fee $100.00
Scanning Fee $3.00
Technology Fee $2.40
Total: $111.80
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is urate at all work will be done in compliance with all applicable laws regulating
construction and zoning. Futhermore.I authorize the above-named tr to do the work stated.
January 06,2016
Authorized Signature:Owner / Applicant ctor / Agent Date
Building Department Copy
January 06,2016 1
Miami Shores Village
10050 N.E.2nd Avenue NE
Miami Shores,FL 33138-0000
Phone:
f
Expiration: 0312012016
Project Address Parcel Number Applicant
1275 NE 94 Street 1132050100090
Miami Shores, FL 33138-2946 Block: Lot: JAMES AND JANINE TURK
Owner Information Address Phone Cell
JAMES AND JANINE TURK 2020 N BAYSHORE Drive
MIAMI FL 33137-
2020 N BAYSHORE Drive
MIAMI FL 33137-
Contractor(s) Phone Cell Phone Valuation: $ 2,500.00
MIAMI DADE WATER&SEWER DEPT (786)256-5200 Total Sq Feet: 4
Scanning:1 Available Inspections:
Inspection Type:
f ® Final
Excavation
Review Building
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $1.80 Invoice# PW-12-15-58109
DBPR Fee $2.00 12/21/2015 Credit Card $111.80 $0.00
DCA Fee $2.00
Education Surcharge $0.60
Permit Fee $100.00
Scanning Fee $3.00
Technology Fee $2.40
Total: $111.80
Applicant Copy
For Inspections, Call (305) 762-4949 or Log on at https:/Ibldg.miamishoresvillage.com/cap/.
Requests must be received by 3 pm for following day inspections.
NOTICE: In addition to the requirements of this permit, there may be AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER
additional restrictions applicable to this property that may be found In GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT
the public records of this county. DISTRICTS,STATE AGENCIES,OR FEDERAL AGENCIES.
December 21,2015 2
Virtual Terminal Page 1 of I
Transaction Approved
MIAMI SHORES VILLAGE HALL
MIAMI SHORES, FL
305-795-2207
Reference Number: 0285
Cardholder: NESS CARMEL LLC
Account Number: XXXXXXXXXXXX8832
Card Type: Visa
Approval Code: 124089
AVS Result: NO MATCH
DatelTime: 12/21/1510:19:19
Sale: $111.80
Total: $111.80
Cardmember acknowledges receipt of goods and/or
services in the amount of the total shown hereon and
agrees to perform the obligations set forth by the
cardmember's agreement with the issuer.
SIGNATURE
Process another transaction
03996-2015 6Ts Corporation. For Customer Service please call 1.800.834.7790
Terms of Service
�.7
t
s,:.
c..s
IVf
t'J
https://www.etsemoney.com/ASPSEC/Merchants/DirectTrans_DRF3/bottom3.asp?CID=... 12/21/2015
PIT
Miami Shores Village DE Q15
Building Department
10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION UNE PHONE NUMBER:(30S)762-4949
FBC 2014
BUILDING Master Permit No.�w
PERMIT APPLICATION Sub Permit No.
F-1 BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL KPUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
10B ADDRESS:^Z2
City Miami Shores County Miami Dade Zip:
Folio/Parcel#: fid�— (9�0 —09_fJ_is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): �l�� >_S �K Phone#:
Address /,,I
r
City: ,�,'1/ /L1/ State: Zip:
Tenant/Lessee Name: Phone#:
Email-
CONTRACTOR:Company Name. a v` ltd Phone#: A or-a
Address:_ 7� L.> a? 9: on
Ci
ty:
State: Zip:
Qualifier Name:
���� 0�27t�i/t Z Phone#: 756- .Z6 9
State Certification or Registration M Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: �/ City: State Zip:
Value of Work for this Permit:$Of—
OP dT--) Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: li✓�
Specify color of color thru tile:
Submittal Fee$ _Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$
(PAAsedO2/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application Is hereby made to obtain a permit to do the work and installations as Indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction In this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding S25W, the applicant must
promise in goad faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certiJfed copy of the recorded notice of commencement must be posted at the Job site
for the flrst inspection which occurs seven (7) days after the building permit is issued. in the absence of such posted notice, the
Inspection will not be approved and a reinspection fee will be charged.
SignatureSignatur
OWNER or AGENT CONTRACTOR
The foregoing instrument was acki owledged before me this The foregoing instrument was ackn wiedged before me this
day of I �G � .20/S� ,by A?day of /� ��201S— by
�s�-/.fid''[ �o4,ke0who is personally known to CSC C�C�J&Ad1.., A' (Z,who Is personally known to
me or who has produced as me or who has produced as
Identification and who did take an oath. identification and who did take an oath.
NOTARY PUB C: NOTARY PUBLIC:
Sign: ���„ Sign:
DENISE CHUNG
Print: �? Print
MMOT
MAW!"-
AA
Seal: -"� ae My Co m.Expires Aug 12,2018 Seal: =�?�•EvA, Rotary Public-State of Florida
°o;;�o��t�::� Commission#FF 113828 y My Comm.Expires Aug 12,2018 Commission#FF 113828
!•ltbS4ti9+P9��RrS4P�t84M�FMtt*9taM9ti�tat�B�PpM�b4�RtMi4t64��E�&88MtiiAtrir*triiitR t • • t ..... '*..B *..
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
J
Water and Sewer
PO Box 330316.3575 S.Le' une Road
MIAMI•DADE Miami,Flori -0316
471
miamidade.gov
v �y
December 16,2015
Miami Shores Village
Building Department
C/o Mr. Ismael Naranjo �� r
Building Official Director
10050 NE 2 Ave
Miami Shores,Fl 33138
Re: Water Service Installation and Retirement for:
1
1275 NE 94 ST
AFA-75 ER-16958
AFA-106 ER-16967
Dear Mr.Naranjo:
Transmitted herewith for your approval and permit are one(1)copies of the water service
installation and retirement for the above referenced project. Upon approval and issuance of
the permit, it is requested that you return to us one copy of the approved sketch and the
original permit.
If your approval and issuance of the permit has special restoration requirements,we will need
to notify the customer of the additional charges involved with the installation. Please inform
us if there will be special restoration requirements for this permit request.
Should you have any questions regarding this matter,please advice.
Sincerely,
.. ... . . . . . ..
. • . ••• .
Isabel Rodriguez ...• • • • •.. . . .• •
.. ..
New Business Representative
New Customer Division. . ... ••• ••• .:0
(786)268-5134
. •• . • ••
o
AYA miami a e.gov ... •• . •
. . . ...
. .. .. . . . ..
000 0 0 0 000 0 0
Miami-Dade County-Application Title
Type of Installation VNew Installation Q Repair/Maintenande Q Both
Method of Installation:
Q Bore VExcavation Q Both
Location of Installation: Within Right Of Way Q Public Utility Easement Q Both
Will work commence Q Yes Q(No
15 days of permit
issuance?
Estimated Start Date: 30 DAYS
Canals maintained by Miami Dade County*111 require DERM approval.
Cayals NOT maintained by Miami Dade County will require a permit from South Fkvfda Water Management Dk*fct
Acknowledged
Pedestrian Information
1. Does excavation fall within the swale and/or Wps Q No
sidewalk area?
2.Give dimensions from edge of pavement to ® FT
Work Zone in swale area.
3.Will work damage existing sidewalk,curbs Q Yes (2SNo
and/or gutters?
4.Will work obstruct pedestrian access to Q Yes VNO
sidewalk?
5.Will work obstruct pedestrian crosswalk or Q Yes Q(No
ramp?
6.Will work obstruct bike path? Q Yes Q(No
PedesMans,including persons with disabliNes will be provided with a reasonably safe,oonvenlen4 and accessible path
r!cafes as much as practical the desirable characterfsfics of the existing pedestrian fadlities.
nowledged
Roadway Information(Are removing asphalt on a paved roadway)
7. Does the excavation fall on the asphalt of a Q Yes Q(No
paved roadway?
8.Does excavation fall within a Signalized Q Yes (960
Intersection?
9.Does excavation fall within a Mid-Block Q Yes Q(No
Signal?
10. Does excavation damage any traffic loops? Q Yes (9 o
11. Have the roads,which are impacted by the
proposed work recently been paved or Q Yes Q60
resurfaced?
Traffic Control Plan
12.Will work require a lane(s)closure for
Vehicular Traffic? Q Yes VNO
13.Give dimensions from edge of pavement to Fl
trench of pole:
14.Provide number of lanes and direction that North: South: ••Gast • • •]Nest: . •
will be affected. • • •• • • • • •
• •• • • • • ••• •
15.Please provide an estimate of construction N/q DAYS ' ' ' ' ' ' '
time for which traffic flow will be affected •• ••• •• • • • ••
16. Functional classification of Roadway
affected by work. ❑Arterial ❑CollectorLocal 000 . 00* ••• 060
17. Does workzone fall within Section Line or • • • • • • • •
Half Section line roadway? Q Yes No '•: ;• • ,•, :• ' :•• :•
MPH
18. Posted Speed Limit within work zone. 000 • • • • •
0
At-grade Appurtenance(If you are placing a cabinet,or some other type of equipr%n ton the groint:Do0:0 nota se •
• • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
3/4/2014
i
VILLAGE OF MIAMI SHORES N
MIAMI-DADE COUNTY
SEC. 5-53-42
SCALE: N.T.S.
Q
LOT-9 LOT10 LOT11 '
1275 240'* m
� r
RM
25' -- ------- -------- ---�-• Z
Ir w •�'•'�'�'�'�'����•'�•�':19' PAVEMENT:;��:;::';�:•,: '•'�•'�:•'•
-}� .--ter,+-,�w•. -,r-, �•:'�r: '•'
25'
RM;
NE 94 STREET 13.5'
EXISTING 6"C.I.
AFA-75 ER-16958 WATER MAIN
NEW 2" DOMESTIC SERVICE AFA-106 ER-16967
SET BOX AND SPACER
RETIRE EXISTING
LOCATE AS MARKED OR SERVICE LOCATED
STAKED AT EAST PROPERTY AT EAST PROPERTY
LINE LINE 20'WEST OF
POLE
GENERAL NOTES NEW WATER SERVICE AND
1. LANE CLOSURES PER F.D.O.T. DESIGN STD. INDEX#602. EXj9TlJ4:'„ •,��• rERV�.E
2. PAVEMENT RESTORATION PER M.D.C.P.W.M.R-21.1. R �'�• • •]�i : kf
3.SIDEWALK RESTORATION PER M.D.C.P.W.M. R-13.1.
4. MAINTAIN MIN.30"COVER ON ALL SERVICE LINES. 1275..14E 94.STREF.T
5. DO NOT SET METER(S)AT THIS TIME. . . . . . . .
6.48 HOURS BEFORE DIGGING CALL SUNSHINE STATE ONE •• • • • • • •
CALL AT 1-800-432-4770 TICKET#. 349500405 000
p • • •
❑ FL.CITY GAS 9f M.D.PUBLIC WORKS COMCAST AFA-75 ER-16958
12f PEOPLES GAS Wf A.T.T. ❑ ATLANTIC COMM. AM 9 06ii :.P Wl D9(1
2f F.P.L. [I M.D.ENT.COMM. ❑ CLEAR • • • • • • • •
• .. .. • • • .. ..
DRAWN: H.B. DATE: 12/15/2015 1 CKD: ••• •.• .
MIAMI -DADEAfNATCR AND SEWER DEPARTMENT
Miami-Dade County-Application Title
Drainage Information
23. Do the proposed construction plans alter or modify not applicable d
existing drainage system?..............................................
24. Does the proposed installation interfere with existing drainage not applicable d
facilities?
Miami Dade County Water and Sewer Department's customer division proposes to perform the fallowing
work within your right-of-way
Total length of underground installation or
repair
Quantity
Water service connection: I ILF
Sewer service connection: LF
Construction or Replacement of Resurfacing
0
Sidewalk Quantity In Public Right Quo LF Of Way SQF
Curb&Gutter LF On private SQF
Valley Gutter LF property
Save Proceed
• • • . • • • • • it
•• ••• •• • • • ••
• • • • • • •
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
• • • • 0000
ROAD •0 0 •• • •
WORK •00.06 • •• • 0000
•
2Q,
AHEAD •000 •
• • •
• 0000
•••• • • • •
• f ••0.6•
A 0000 • f •••
•• •• •• • • 0000
0000•• • •
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ • • • • • 0000
Is ■ ■ ■
■ h 0000••
B Taper Length m ViL Wark Area r"st 0 f•• • 000046
see TabletJ END Table 11 • •i 6 •
ROAD ROAD WORK Taper Length - Shoulder• •
WORK Device spaci -raper Device spacing-Tangem 500 fes)
See Tablet See Table 1 _
AHEAD SPdHDitf ytNtB (.Ph) r 10 17 Notes
11011BI.ED
INEN ApRtERS Shidr. Shidr. ShWr.
PPESENT
25 28 35 42
Table 1 30 40 so 60 L=WSr
Device Spacing 35 55 68 82 60
Max.Distance Between Devices(ft.) 40 72 90 107
Speed Cones or Type I or Type a 45 120 ISO 180
(mph) Tubular Markers Barricades or Vertical 50 133 167 200
DISTANCE BETWEEN SIGNS Panels or Drums
Spacing(ft.) Taper Tangent Taper Tangent 55 147 183 220
Speed 60 160 Z00 240 L>WS
A B 25 25 50 25 50
40 mph or less 200 200 30 to 45 25 50 30 50 65 173 277 260
45 mph 350 350 50 to 70 25 50 50 100
50 mph or greater 500 500 70 187 233 280
'Midway between signs. B minimum shoulder width
W- Length of shoulder taper in feet
SYMBOLS GENERAL NOTES DURATION NOTES W= Width of total shoulder in feet
(combined paved and unpaved width)
® Work Area 1.When four or more work vehicles enter the through traffic lanes in a one hour I.Signs and chatmelizing devices may be omitted if all of the
Sign With 78'x 18°(Mtn.)Orange period or less(excluding establishing and terminating the work area),the advanced following conditions are met: S- Posted speed limit(mph)
v FLAf,GER sign shall be substituted for the WORKERS sign.For location of fiaggers a.Work operations are 60 minutes or less.
Flag And Type B Light and FLAGGER signs,see Index No.603. b.Vehicles in the work area have high-intensity,rotating,
flashing,oscillating,or strobe lights operating.
■ Channelizing Device(See Index No.600) 2.SHOULDER WORK sign may be used as an alternate to the WORKER symbol sign only
on the side where the shoulder work is being performed.
D Work Zone Sign 3.When a side road Intersects the highway within the TTC zone,additional TTC
devices shall be placed in accordance with other applicable TCZ Indexes.
b Lane Identification+Direction of Traffic CONDITIONS
4.For general TCZ requirements and additional information,refer to Index No.600. WHERE ANY VEHICLE,EQUIPMENT.
WORKERS OR THEIR ACTIVITIES
ENCROACH THE AREA CLOSER
THAN IS'BUT NOT CLOSER THAN
7 TO THE EDGE OF TRAVEL WAY.
R
LAST C DESCRIPTION: 2015 INDEX ;of
HEET
REVISION FOU-1� TWO-LANE, TWO-WAY, WORK ON SHOULDER NO. NO.
07/01/12 �- DESIGN STANDARDS 602 1