RF-16-104 ti Y Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-250906 Permit Number: RF-1-16-104 Scheduled Inspection Date:April 12,2016 Permit Type: Roof Inspector. Rodriguez,Jorge Inspection Type: Final Roof Owner. ROESSET,JOHN Work Classification: Flat Job Address:798 NE 98 Street Miami Shores, FL 33138- Phone Number (917)621-6251 Parcel Number 1132060142290 Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL&SUPPLY CO.INC Phone: 305.757-2612 Building Department Comments REROOF ENTIRE WITH NEW BORAL SAXONY SLATE Infractio Passed Comments COLOR THRU FLAT TILE(CEMENTO AND 13.1.11 MODIFIED INSPECTOR COMMENTS False ON FLAT Inspector Comments Passed Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid April 11,2016 For Inspections please call: (305)762-4949 Page 9 of 37 ot:: t 6- [0(f GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES DRILLING SERVICES rDEc DYNATECH ENGINEERING CORP, — �m—�-jc i/ WW'.DYNATECHENGINEERING.COM CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 MIAMI,April 11,2016 PERMIT No.RF-1-16-104 CLIENT:Jim Obenour:OBENOUR ROOFING:9822 NE 21d Avenue,Suite 9,Miami Shores,FL 33138 PROPERTY ADDRESS:798 NE 98TH STREET MIAMI SHORES,FL 33138 TILE TYPE/ATTACHMENT:Flat Roof Tile Polyfoam Set. Inspected By:JM Testing Equipment:Humboldt Scale Model H-4620 The test results presented here reflect the condition of the roof system at the time of the test.These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and rooftop traffic Test No. Test Location Field Uplift Pull Test Test Result 1 - 114 Field See Sketch Below >Than 35 LBS Passed 115-130 Corner See Sketch Below >Than 35 LBS Passed 131 - 176 Perimeter See Sketch Below >Than 35 LBS Passed 177-231 Ridge caps See Sketch Below >Than 35 LBS Passed ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 ROOF SKETCH 1 8 3 9 1 j1] ll0 109 ,_ 336-336_�< `4 27 121 197 163 104 103 106 9 :141 17A 1 108 331 95 91 92�' M 101 300 16 @ 1142 46 1 80 420` : 94 93�r ea79 98 `$ 17 18 14 3'�->•; 68 67 21 tab 81 E9- 173: 83 3 69 70 73 i1 27 28 144 ; 171 980 674 1 60 25 26 31A�;4 73 72 4 ''' 3D �1 4 33 _ 7,1 t'`^' '' r J68 63 56" 6 32 169 1 6 161 i ` 36 37 38 la t i 64 62 57 58 10619 77 10 4 '_40 41 I68;1 7 6- 63 59 56 1147 2 39 43' - � 54 1591 1 40 42 1� u19149 5 °944'las ��N�:5911a1�4t 47 46 g0 at pnrt SYotloq nr � ardia�net onrtwo9 tWc Sincerely yours, ------------------;�- 1 _4/it ba c Wissam Nwfani,P.E. DYNATECH ENGINEERING CORP. Florida Reg.No.39584 Special Inspector No. 757 750 WEST 84TH STREET.HIALEAH,FL 33014 PHONE(305)828-7499 FAX(305)828-9598 EMAIIJNFOODYNATECHENGINEERING.COM AP C