Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-13-914
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-197619 Permit Number: RF-5-13-914 Scheduled Inspection Date: August 20,2013 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: CENOZ, EFREN Work Classification: Tile Job Address:51 NW 110 Street Miami Shores, FL 33168-4318 Phone Number 305/751-5274 Parcel Number 1121360030600 Project: <NONE> Contractor: DB BROTHERS CONSTRUCTION INC Phone: (786)402-9625 Building Department Comments RE ROOF TILE TO TILE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-190390. Replace broken/cut tile Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 19,2013 For Inspections please call: (305)762-4949 Page 27 of 32 ! _ .� , �•1 C�Il11� 5; A-1 CONSULTING ENGINEERS . INC ROOF STRUCTURES CONSULTING ON SITE CONCENTRATED UPLIFT LOAD TESTING ROOF TILE .. IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE TAS No. 106 UPLIFT TEST EXPERTS �-- SITE SPECIFIC INFORMATION Owner's Name: T/' l/! �r7a�- Permit Job Address: _ J`—1 Al l f/ l/� �`T �� 141/ F' Roofing Contractor:_Z,4.0 e5�9,00rj7�/���/��/ Type of Tile:U�'��c�.,4 Date installed: Approximate Roof Height:��feet Roof Pitch: 5-f/2, Type of Access to Roof: i/ Scaffolds Ladder Other Approximate Square Footage of Roof: Z7. O-0 ft 2 Required Testing Force: 35 lbs. Testing Equipment: F.G.E. 100 Date Tested: ST LOCATION UPLIFT PULL TEST rEST LOCATIO UPLIFT PULL TEST TEST LOCATIOI UPLIFT PULL TEST TEST LOCATIO UPLIFT PULL TEST I rEST LOCA7101 UPLIFT PULL TEST rEST LOCATIO UPLIFT PULL TEST 1 ' 26 73 51 c� 76 101 126 2 27 1 52 177 1b2 127 3 28 53 178 103 128 4 29 54 179 104 129 5 30 55 80 105 j 130 6 31 56 81 106 131 7 32 57 82 107 132 8 33 58 83 108 133 9 34 59 84 109 134 10 35 1 60 85 110 135 11 36 61 86 111 136 12 87 62 87 112 137 13 38 63 88 113 138 14 39 64 89 114 139 15 40 65 90 L115 140 16 41 66 91 1 141 17 1 42 67 92 7 142 18 43 68 93 143 19 44 69 94 19 144 20 45 70 9 5 21 46 71 96-p, 121 146 22 47 97 147 23 48 73 98 2 148 24 49 74 99 124 149 25 50 k 75 100 125 150 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106,THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CON- TROL TEST.THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY,WITH NO DEVIATIONS. THIS REPORT SUBMITT D BY: Jose A.Martinez P.E.#031509 A-1 CONSULTI , IPJC. Lab. Certif ion#07-0306.03 Renews:01-1224.05 4383 S.W. 70th Ct, Miami, Florida 33155 • Telephone (305)740-9550 • Fax(305) 740-9550 ENGLISH: Cell (305) 609-6388 • SPANISH: Cell (305) 498-9804 X-1 t0TXS= ENGMFURS INC. rsTTLNG UP=TEST ET LAB. CERTIFICATION No-81 -14224-3 4383 Sw_7CTeINIMANIH FL. 33155 .305-740-9550 F-A . 5- 4.0- 55 ` : Per °t : Roofing contractor. LAO CONSTRUCTION- Type of tile: VEREA d=ate Read: -Approximate roo height- 16 feet Roof pith: 5,112 Tip of access to..roof: Scaffold-- Ladder Other. Apprmimate square footage of roof. 27_ Requited testizig fore: 35 lb Date tested; . Number of tests: 73 SKFFCH F ROOF -3 �7 E` ZB Z,c ` , .� _ 22 � �' 721 _ .M 1 R 9 ; 2 & °RFsy Miami Shores Village onesoBuilding Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 A�R�p► Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit# �'s-13- ��� DATE: INSPECTION AFFIDAVIT I z o betel yam''' licensed as a(n)Contractor/Engineer/Architect, (Print name and circle License Type) FS 468 Building Inspector License#: ( C On or about ©-3 i3 Aim , I did personally inspect the roof deck nailing and (Date&time) � V Secondary water barrier work at � � �W 1 10 .Sr>ee Ii q,r1. �nr (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) ignature BERTHA C.ORTEGA r Notary Public-State ofFlorida My Comm.Expires Sep 27,2016 State of FloridaCommission#EE 205198 t,5oP�, Bonded Through National Notary Assn. County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this '4-c) day of US odd Notary Public, Sate of Florida at Large *General,Building,Residential,or Roofing Contractors or any individual certified under 468 F.S.to make such an inspection.Include photographs of each plane of the roof with permit#and address#clearly shown marked on the deck for each inspection Revised on 5/21/2009 Miami Shores Village �o� Building Department artment _l a� 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 5-Y ---__me_e--mv_ Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER:(305)762.4949 pF�B-C 20 BUILDING Permit No.4?" 15—91 Ja ' PERMIT APPLICATION Master Permit No. >.'7--9 Permit Type: BUILDING ROOFING JOB ADDRESS: + r'h v I 10 �T City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: I —Z ©p 6eD Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): VPV�e-J C'ff�r7--L— Phone#: 41 X t® -4L-' Address:��_ City: V-k'l A l Stater Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name.D, r oAT i GI`S (A'YLS4r, -INC, Phone#��� Address: t2 1 20 S �,V , C---T-1 City: ��>^-�- State: rn , Zip: 3 Qualifier Name:`/C.,o e- ) est-Gt (''�-'�. Phone#: �� q 2 State Certification or Registration#:C C C- 3 Certificate of Competency#: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Phone#: Value of V�'ork for this Permit: $ 4 .J ✓ S�uare/Linear Footage of Work: 4. Type of Work: DAddition ❑Alteration Cr7New ❑Repair/Replace ❑Demolil4on Description of Work:. /?4e9l' Color thru tile: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ w Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN * YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will vat-be a reinspection fee will be charged. Signature -- �_. Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this cZ-i The foregoing instrument was acknowledged before e • r M o ft i Y1 ,20 3,by ��1�29't C.:,2►r1D Z day of A Y� ,20�,by nally known to me or who has produced h L, who is personally known to me or who has produced i� CDC � •+ � O °q� •',�^0 As identification and who did take an oath. as identification and who did Qiri ow- � Ihl„114 7 bi G O t NCR" PUBLIC: NOTARY PUBLIC: E '—H o co d 3 3 m m 9 v v o oy3 � �o Za. Sign: g o l�ir�:» e,r�Ot �• Print:at M call two =� _ ozlty'X Sion Expires: Se b a-+t a o �46 My Commission Expires: Se-p Q in V 71 D I ��IIIIIIin�,, y m ro m � m rn APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 5/2/2012 Revised 3/92/2012)XRevised 06/10/2009X Revised 3/15/09)(Revised 7/10/2007) TE AC l20 vF CERTIFICATE OF LIABILITY INSURANCE DA04/29/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTMATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT EVELYN MARTINEZ NAMJUST INSURANCE SERVICES (PA"ICNMo . 305-246-3153 AA.,,): 305-246-3145 28931 SOUTH DIXIE HWAY EMAIL ADDRESS: HOMESTEAD,FL 33033 INSUREMS)AFFORDING CIMMME NAICII INSURER A: GRANADA INSURANCE COMPANY INSURED INSURER B: DB BROTHERS CONSTRUCTION INSURER C: 27120 SW 144 CT INSURER D: NARANJA,FL 33032 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. MSR TYPE OF INSURANCE �� POLICY NUMBER SR Lel'EFF POLICY EXP LUUM LTR GENERAL LIABILITY EACH OCCURRENCE $ 500,000 X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence $ 1001000 CLAIMS-MADE F—I OCCUR MED EXP(Any one person) $ 5,000 A 0185FL00039762 10/03/2012 10/03/2013 PERSONAL&ADV INJURY $ 5,OW GENERAL AGGREGATE $ 500.000 GE 'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOP AGG $ POLICY PRO- LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per ac cident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION 7 WC STATU- OTH- AND EMPLOYERS'LIABILITY YIN LIMITSI TORY E ANY PROPRIETORIPARTNERIEXECUTWE ELL EACH ACCIDENT $ OFFICEMMEMBER EXCLUDED? El N I A ( andaWry In NH) EL DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS bebW El.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 701.Additional Remarke Schedule,it more space Is requhed) RESIDENTIAL CONSTRUCTION CERTIFICATE HOLDER CASIVELLATION 1 SHO LO ANY OF THE ABOVE D RIBED POLICIES BE CANCELLED BEFORE THE ORATION DATE TH EOF, NOTICE WILL BE DELIVERED IN MIAMI SHORES VILLAGE BLDG.DEPT. ACC DANCE WITH THE uC PROVISIONS. 10050 NE 2ND AVE — - 7 MIAMI SHORES VILLAGE,FL 33168 Erol TIVE M1 h I 0 19K AC RD RPORATI All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD 10-12-2012 t JEFF ATWATER STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 10/12/2012 EXPIRATION DATE: 10/12/2014 PERSON: DUARTE ROBERTO J FEIN: 650810492 BUSINESS NAME AND ADDRESS: D B BROTHERS CONSTRUCTION INC 27120 SW 144TH CT, MIAMI FL 33032 SCOPES OF BUSINESS OR TRADE: 1- ROOFING 2- LICENSED GENERAL CONTRACTOR IMPORTANT: Pursuant to chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed an the notice of election to be exempt. Pursuant to Chapter 440.051113), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation If, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413-1609 DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATE OF FLORIDA IMPORTANT DEPARTMENT OF FINANCIAL SERVICES O Pursuant to Chapter 440.05114), F.S., an officer of a corporation who DIVISION OF WORKERS COMPENSATION CONSTRUCTION INDUSTRY elects exemption from this chapter by filing a certificate of election CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA L under this section may not recover benefits or compensation under this WORKERS COMPENSATION LAW 0 D chapter. EFFECTIVE: 10/12/2012 EXPIRATION DATE: 10/12/2014 Pursuant to Chapter 440.05112), F.S., Certificates of election to be PERSON: ROBERTO J DUARTE H exempt.. apply only within the scope of the business or trade listed on FEIN 650810492 R the notice of election to be exempt BUSINESS NAME AND ADDRESS. E Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt D B BROTHERS CONSTRUCTION INC and certificates of election to be exempt shall be subject to revocation 27120 SW 144TH CT, if, at any time after the filing of the notice or the issuance of the MIAMI, FL 33032 certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the SCOPE OF BUSINESS OR TRADE. person named on the certificate to meet the requirements of this 1- ROOFING 2- LICENSED GENERAL CONTRACTOR Section. QUESTIONS? (850) 413-1609 CUT HERE * Carry bottom portion on the job, keep upper portion for your records. DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 IACSTATE OF FLORIDA 6420580 j DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION iI CONSTRUCTION INDUSTRY LICENSING BOARD SEWL12092805762 I - LICENSE NBR i j - 109/28 /20121127016949 CCC1327633 The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 46;9 FO- Expiration date: AUG 31, 2014 DUARTE, ROBERTO JOSE 1 D B BROTHERS CONSTRUCTION INC 27120 SW 144TH CT FL 33032 i MIAMI I RICK SCOTT REN ON GOVERNOR SECREETARTARY DISPLAY AS REQUIRED BY LAW FlRST-CLASS U.S.POSTAGE PAID MIAMI,FL PERMIT NO.231 705959-5 THIS IS NOT A BILL—DO NOT PAY NEW BUSINESS NAME/LOCATION RECEIPT NO. 733732-2 DB BROTHERS CONSTRUCTION INC STATE* CCC1327833 27120 SW 144 CT 33032 LININ DADE COUNTY OWNER DB BROTHERS CONSTRUCTION INC Sec.type of Business WORKER/S 196 SPECIALTY BUILDING CONTRACTOR 1 THIS IS ONLY A LOCAL BUSINESS TAX RECEIPT.IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING ES THE OR C COUNTY OR CITIES. NOR DO NOT FORWARD DOES n EXEMPT THE HOLDER FROM ANY OTHER DB BROTHERS CONSTRUCTION INC PERMIT OLICENSE REQUIRED BYRLAW.THIS IS ROBERTO J DUARTE PRES THE HOLDERS CERTIFICATION QLL[FF,CA- 27120 SW 144 CT TIONS. NIANI FL 33032 PAYMENT RECEIVED MIAMI-RADE COUNTY TAX COLLECTOR: 10/29/2012 09010081001 8 000075.00 I SEE OTHER SIDE Property Search Page 1 of 7 w x MIAMI-DADS COUNTY OFFICE OF THE PROPERTY APPRAISER Carlos Lopez-Cantera -- � PRCPER7YAPp3iAtSER _ Property Appraiser Exemptions& Real Estate Tangible Public Online Tax Roil About Us Contact Us Home Other Benefits Personal Property Records Tools Administration Selected Properly Information Aackto results Properly Information Full Legal Description 3 Assessment Information Year. 2012 2011 Assessment Information Land Value: $44,981 Exemption Information _cam BulldingValue: $1,0:28 $144,114 Market Value: $189,095 Sales information f Assessed Value: $189,007 $189,095 .............._...._.._......_..____......_...............-............................_.—_....__..........._._--.._....._............_........................_..—._...__......... .._.3 AdditionalInformation __... __...—_..._....._........_.._..._........._....--- ---._...............-..._..._.._.-...._..---......__.._.._...... +___.._._.......__�_..__.........-._ Taxable Value Information Featured Online Tools Exemption/ Exemption/ Taxable Value Taxable Value Tax Comparison County: $0/ $0/ $189,007 $189,095 Tax Estimator School Board: $0/ $0/ TRIM Notice ! $189,007 $189,095 City: $0/ $0/ View Taxes $189,007 $189,095 I Regional: $0/ $0/ Additional Online Tools $189,007 $189,095 Property Sales Fma RM s `h 6, t g - � a.✓ a ° .. �'t+ M � s ' u The Office of the Property Appraiser and Miami-Dade County are continually editing and updating the tax roll and GIS data to raftect the latest property information and GIS positional accuracy No warranties,expressed or implied,are provided for data and the positional or thematic accuracy of the data herein,its use,or its interpretation.Although this website is periodically updated,this Information may not reflect the data currently on file at Miami-Dade County's systems of record.The Property Appraiser and Miami-Dade County assumes no liability either for any errors,omissions,or inaccuracies in the information provided regardless of the cause of such or for any decision made,action taken,or action not taken by the user in reliance upon any information provided herein. http://gisweb.miamidade.gov/PropertySearch/ 5/2/2013 AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami-Dade County Building&Neighborhod Co lance rtment 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name Property Address Roofing Permit Number Dear Building Official: I , certify that I have improved the roof to wall connections of the referenced property as re ired the Manual of Hurricane Mitigation Retrofits for Existing Site-Built Si e ily Residential S res as adopted by the Florida Building Commission by Rule 9B-3.047 F. C. a.tfrre ofua.lifI _ Agent 2a 'Print Name C-C G - 133 V33 License Number STATE OF FLORIDA COUNTY OF MI-DA Sworn to and subscribed before me this day of bri. / ,20 1 3. (SEAL) � , BERTHA C.ORTEGA Personally known Notary`�: Notary Public-State of Florida EOL or Produced Identification s• My Comm.Expires Sep 27,2016 Commission#EE 205198 �•� 6onded Through National Notary Assn. � s- P,,�,,,,�E OWNER'S NOTIFICATION FORM SECTION 1524 HIGH VELOCITY HURRICANE ZONE—REQUIRED OWNERS NOTIFICATION FOR R I FI Stb TIONS 1524.1 Scope.As it pertains to this section, it is the responsibility of the roofing cont ractb p� .el.t e ow r with the required roofing permit, and to explain to the owner the content of this section.The provisions of Chapter 15 of the Florida Building Code,Building govern the minimum requirements and standards of the industry for roofing system installations.Additionally, the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initials in the designed space indicates that the item has been explained. P0J1yXesthetics-workmanship:The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. Renailing wood decks:When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). EAPCommon roofs:Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants and adjacent units of roofing work to be performed. ®Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable.The owner provides the option of maintaining its appearance. 0 t. Ponding water:The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Ep6-Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Code,Plumbing. ®.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly(the building itself).The existing amount of attic ventilation shall not be reduced. Exception:Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate the attic venting, shall not be required. Owner's/Agent's Signature: Date: ® / T? / Wo Contractor's Signature: Permit Number: Property Address: 5-1 N W l D 57 12301-197 12/09 • � T ��� ort 2007 f Hlgh Wooly HwriCam Zone Wdfom P8tr i ApplWatlon Form SeWon No job Addoem51 lel ROOFCATEGORY ® Low Slope MealmnicallyFOGWROCIT" )KMoftdAdlw8W9fWTll0 ® ® wood Bld. P Shakes 3 togs Are there ® BUR4W 900 Gas Vent Stacks? 0 Yes❑ Hqx ® a F ROOFTYPE Type; Natural❑ LPGXU Pjg 1 7- ® Re■Rooft Repair ® oe Cl R INFORMATION Slope Roof Area(311) Steep Moped Roof Area(SF) Tolal(811) Aza C zC) U Lig Plapi fl Roof Pim Mtnftde all dhr sloes �YeI8ed sections, root dmhM 8CUPP*m, 1�lROw Q O deaft LE 0Y 3 onn.wW location of pwapotL wi_r L4 k. r� —T —TVA., a a Vl ._.. � f .moi q ` 14, {f i Y ' - � d x-..e-a �- ♦ 1 z ..� e - _ 4 F zt f 1_ . Ad J, 3.r �13i f L k � Y i.. E--. - � !�: �j- �--'y-*-�--}_ t-�. � i �T- ���.r•.�f� Y{ 13, k. t Y- '� 1230148 12=PAGE 2 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section D(911910 Slowd Roof Svsteml Roof System Manufacturer: Q Aa rC Notice of Acceptance Number: 13 0Z.z 02. Minimum Design Wind Pressures, If Applicable ( From RAS 127 or Calculations ): P1: �.S' P2:_ `7 9.-4 P3:_ 114, 2 Sett S D$" Roof SOMOR fl Isado ►, Deck Type: /q3 2 �l �5slope Type undernt .� o C � ., _ dnsub lion: Fre Baader, 'v Iden latix�n� Fastener Type&Spacinw s �aG�C G`�O Adhesim Type: Type cap Sheet: Mom Rod HeWht � Rod Covwing Type&Size Grip Edge: Page 4 of 5 Florida Building Code Edition 2010 High-Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) Pm faea�lad� dwowekhwMadwdIarLedavajgftFor[4 &,,s6 mNlf. s�ev�aaaoe at4awvr eqmw is&r M,v ksm Ger era&area of&M rM4 to dw t& c!S Med ad 1 78e CakamUm Rrr m Irr 't= ,61 -Md 10.44. �G3°212 [Pz:7g•/--k037 - Dp- .DI -ma.!Z.r-ma.! ftwaApp-wm# 45.7-/Z dl � Appmggyp e�.?r L lib cAmkftm Fer yabig Elelm- W eWdFmwT*k PtAmAp—.1A`3 ZIZ_ M,tired Aliment • Wsn Root HdUM-� Rod SWps 1 13 2r 38' 4W 212 3+44 38.5 382 39.7 422 3:13 322 alt 36A 37.4 39.8 4:12 314 322 232 1 37.3 5:13 284 31.1 31A 32.8 344 812 2&4 2LO 29.4 330.5 32A r 12 2t t Ztii 27.1 282 86.0 .Mw be aced'n ,adze a its aa€ t& lei dw SIwwwd CAMW&Dtd OfRWMAW Iitpbttbt8ar arae 3 t�paaedBaesfarFmdtYaeaFet(thee atafano m4islreralnee fix ame1 am roa6 dM i&t Method 2-UpIM Oned T&CAmbdom par US I2r ---j-W x ms 0 -F', F' dpi- x L = x w--....,�.i-W. x cva t =Fe h aden App&W 1a CP,:—x L x m�...)-K x cwit =P6 ftMlbKl Affmmi p to AIM WRMHOM MMM to ftd DeftoFreeware PI orP'2wP3 WLSIVTAkIorbyaea opopmedbyMbNWamASM 7 Rod H ]abne mood slap_ a ReAwi ag Mom o dtae to Gm* ftab a,yppmvA Aaaaa emau H— M, appmi► ftqdwdMGMMRakmw A% Cakmiad M Redadmm F Paadatl Rea[waed ltplllt f or ffr CaisWm d Average rite height w Pm 6K2 AgpmvW T&DW*Kdnn L. i Fto�oct w=a ratan$ AN mkWAmw mum be ubW4bd in Ow W&S a1 id ad treat the of pumm qpbMkm Page 5 of 5 MLALMF MMOMME MIAMI-DADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT )NC PRODUCT CONTROL SECTION BOARD AND CODE.ADMINISTRATION DIVISION 11805 SW 26 Street,Room 208 Miami,Florida 33175-2474 NOTICE OF ACCEPTANCE OA, T(786)315-2590 F(786)315-2599 www-miamidad¢,gov/buildiuPl Polyfoam Products,Inc. 11715 Bordeaux Road Tomball,TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami-Dade County Product Control Section and accepted by the Board of Rules and Appeals(BORA)to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ lm areas other than Miami Dade County) have this product or material tested for quality assurance purposes.If this product or material reserve the e right to in the accepted manner, the manufacturer will incur the a perform immediate) revoke mod' expense of such testing and the AHJ may Y modify,or suspend the use of such product or material within their jurisdiction. BORA, reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Sectioc,that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Polyset®One Roof Tile Adhesive LABELING: Each unit shall bear a permanent label with the manufacturer's name or loo ci state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no ffecting the performance of this product. change in the applicable building code negatively a acture of the product or process.Misuse of this NOA as an endorsement of any TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manuf product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal, "NOA. ADVERTISEMENT: The NOA number preceded by the words Miami--Dade County,Florida, and followed by the expiration date may be displayed in advertising literature If any portion of the NOA is displayed,then it sliall be done in its entirety. IS INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA#09-0622.04 and consists of pages I through S. The subgitted documentation was reviewed by Alex Tigera. �ltANtt n�►ba C �� NOA No.: 10-1112.05 Expiration Date:01/03/16 Approval Date;01/06/11 Page 1 of 5 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: 07320 Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polyset®One as described below in this Notice of Acceptance,designed to comply with the Florida Building Code.For the locations where the pressure requirements,as determined by applicable building code,do not exceed the design pressure values;as obtained by calculations in compliance with RAS 127,using PolysetO One,and where the attachment calculations shall be done as an moment based system. }PRODUCTS MANUFACTURED BY APPLICANT: Prod Dimenslo Product Descriution Polyset®One Factory premixed canisters Single component polyurethane foam roof tile adhesive. IVIANOFACTURING LOCATION: 1. Norton,OH. PHYSICAL PROPERTIES: Prove Test Results Density ASTM D 1622 1.951bsJft.' Compressive Strength ASTM D 1621 7.8 psi Tensile Strength ASTM D 1623 15 PSI Parallel to rise Water Absorption ASTM D 2842 4.6 LbsJFe Moisture Vapor Transmission ASTM E 96 1.94 Perm/Inch Dimensional Stability ASTM D 2126 +0.890/c Volume Change(7a 70°C.,2 Weeks Closed Cell Content ASTM D 2856 54.1% --EVIDENCE SUBNII1m: Test Agency Test IdentiSer Test NWe/Renort Date Southwest Research Institute 01-1208-025 ASTM E 108 06/16/98 PRI Construction Materials FOP-009-02-10 Physical Properties 12/14/10 Technologies,Inc. FOP-009-02-01 TAS-101 11/8/10 FOP-009-02-02 1•AS-101 11/4/10 .1:41 FOP-009-02-03 TAS-101 11/8/10 FOP-009-02-04 TAS-101 11/8/10 FOP-009-02-05 TAS-101 11/8/10 CNQA No.: 10-1112.05 OUR ' Expiration Date:01/03/16 Approval Date:01/06/11 Page 2 of 5 J LD 1TATiONS: 1.. Fire classification is not part of this acceptance. 2. PolyseW One can be used with flat,low,medium and high file profiles. `I Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polysew One roof the adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. riF — W F'= MS INSTALLATION: 1. Polyset®One may be used with any roof tile assembly having a current NOA that lists moment resistance values with the use of Polyset®One 2. Polyset®One shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of Polyset®One shall provide sufficient attachment resistance,expressed as a moment based system,to meet or exceed the moment resistance determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA 3. PolysetO One roof file adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120,and Fomo Products,Inc.Polyset®One Operating Instruction and Maintenance Booklet 4. Installation must be by.a Factory Trained'Qualified Applicator'approved and licensed by Polyfoam Products,Inc. 5. Pressure treated wood filler block shall be required on all eave course of all file profiles except on two pieces barrel tile. 6. Tiles must be adhered in freshly applied adhesive.Tile must be set within 4 minutes after Polyset® One has been dispensed. 7. Polyset®One placement shall be in accordance with the Placement Details'herein. Each generic the profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Typical Placement Weight per paddy Pro51e ]Detail rams Flat,Low&!ggh Profile # 1 12 High Profile 2-Piece #2 12 Barrel LABELiwG: All Polyset®One containers shall comply with the Standard Conditions listed herein. MIAMFDADE NOA No.:10-1112.05 "JAPPROVED1 Expiration Date:01/03/16 Approval Date:01/06/11 Page 3 of 5 ,N BUILDING PERMIT REQU=MENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system, ADHESIVE PLAcFMENT DETAILS RwIN7wP"8V« Cur AWAY VIEW CONTOMCWVM ADHUMOROOM y� PLACEMENT DETAIL#1 owD CO NOA No.:10-1112.05 Expiration Date:01/03/16 Approval Date:01/06/11 Page 4 of 5 ADHESIVE PLACEMENT DETAILS (CONTINUED) PLACEMENT DETAIL#2 1 1 END OF THIS ACCEPTANCE IAMbDADE OUN 11f NOA No.: 10-1112.05 Expiration Date:01/03/16 Approval Date:01/06111 Page 5 of 5 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Polyglass USA Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Sec&n to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0713.02 MIAMMADECOUNTY Expiration Date: 09/13/16 ® • Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Material: SBS,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt underlayment 65'8"x 3'33/8" waterproofing membrane,glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering, underlayment 65' x 3'33/$" ASTM D 1970 APP polymer modified,fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1  60 mils thick underlayment in sloped roof assemblies. Designed as an ice&rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP underlayment 32'l 0"x 3'33/$" ASTM D 1970 polymer modified,fiberglass or polyester Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as #1  an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. C k TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering,glass- yment 65' x 3'33/$" ASTM D 1970 fiber/polyester reinforced waterproofing e Printing) 80 mils thick membrane.Designed as a metal roofing and roof cturing Locationtile underlayment. 2k TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10"x 3'33/$" ASTM D 1970 glass-fiber/polyester reinforced,with a granular Manufacturing Location 130 mils thick surface designed for use as a the roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane.Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. MIAMPDADECO� NOio No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self-adhering,polyester Manufacturing Location 65'8"x3'3-3/8" ASTM D 1970 reinforced waterproofmg membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton,PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Mency Test Identifier Test Name/Report Date Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 &G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 &D1970 10/19/11 P40390. 08.12-1 TAS 103 &TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 &G 15 5 07/06/09 Momentum Technologies,Inc. JX20H7A TAS 103/ASTM D4798'&G155 04/01/08 RX14E8A TAS 103/ASTM D4798&G 15 5 11/09/09 DX23D8B TAS 103/ASTM D4798&G155 02/18/10 DX23D8A TAS 103/ASTM D4798 &G155 02/18/10 NOA No.: 12-0713.02 MutiDADE COUNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4"head lap.(for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2"and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. rtwr�I•naoecouNrr Expiration Date: 09/13/16 NOA No.: 12-0713.02 'I„ ,,,8 - Approval Date: 02/14/13 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS,TU Plus,Tile Pro and Dual Pro may be used in asphaltic shingles,wood shakes and shingles, non-structural metal roofing,roof tile systems and quarry slate roof assemblies.Polystick IR-Xe,TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. Ex osure Limitations(days) MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven,FL. 180 180 180 180 180 180 180 90 Hazelton,PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance.Polystick TU,TU Plus,Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications.Polystick IR-Xe,and Dual Pro are limited to mechanically fastened roof tile applications.Polystick MTS is limited to mechanically fastened with battens roof tile applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)tile assemblies shall be as follows:(See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Polystick TU,TU Polystick TU Plus,TU P,Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens anens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 12-0713.02 MIAMI•DADE COUNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. Roofing Tiles x (6 Max Per Stack) CL �'\� 12 c ..'�z. ... 6 Nv Z ir. r Y 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products.Polystick MTS,IR-Xe,TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe, TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS,IR-Xe,TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. MIAMMI&DE COUNTY ,...1 1 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 12-0713.02 MIAMI-DARE CO; Expiration Date: 09/13/16 11 Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum I"metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area being back-nailed.(Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement,applied in between the application of the lap.The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the Polyglass Tile Loading Guidelines.See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the tile manufacturers NOA's,must be used on all projects for pitch/slopes of 7/12"or greater. It is suggested that on pitch/slopes in excess of 6 '/a"/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. 8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 12-0713.02 MIAMMDADE COUNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 J 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NBCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAM FDADECOUNTY NOA No.: 12-0713.02 M. ,,� Expiration Date: 09/13/16 MIJ Approval Date: 02/14/13 Page 8 of 8 F M. 10 MIAMI-DADE COUNTY r "' PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miwWdade.gov/vera Ceramica Verea Ctra.N-634 San Sebastian,Santiago,Km 683 Lanza S/N 15685 Mesia(Coruna)Spain SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CISpanish "S' Roof Tile LABELING: Each unit shall ear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 11-0722.02 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0226.02 M"IAMI•DADE eouNTY Expiration Date: 03/13/18 Approval Date: 03/21/13 Page 1 of 6 i ROOFING ASSEMBLY APPROVAL, Categorv: Roofing Sub Categorv: Roofing Tiles Material: Clay 1. SCOPE This approves a roofing system using Clay Spanish "S" Roof Tile manufactured by Ceramica Verea, S.A. in La Coruna, Spain and is distributed by Ceramica Verea, USA, as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Clay Spanish"S"Roof Tile L= 19.5" ASTM C1167 High profile clay roof tile. For direct deck, W= 11.3" adhesive set applications. Thickness: 0.44" Trim Pieces Length: varies ASTM C1167 Accessory trim,clay roof pieces for use at hips, Width: varies rakes,ridges and valley terminations varying thickness manufactured for each file profile. 2.1 MANUFACTURING LOCATION 2.1.1. San Sebastian. Spain 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0706.01-11 ASTM C 1167 07/19/11 Florida IBA Consultants,Inc. 4709-3 TAS 101 12/21/07 NOA No.: 13-0226.02 MAWDADE COUNTY U14..® 0 Expiration Date:03/13/18 Approval Date:03/21/13 Page 2 of 6 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set file applications,a static field uplift test in accordance with TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Building and Neighborhood Compliance Department—Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underla}-went applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Clay Spanish"S"Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS-120. 4.2 Data For Attachment Calculations. Table 1: Average Weight(W)and Dimensions(I x w) Tile Profile Weight-W(Ibf) Length-1 (ft) Width-w(ft) Clay Spanish "S"Tile 8.3 1 1.625 0.942 Table 2: Aerodynamic Multipliers -A (ft) Tile A (ft ) A (ft ) Profile Batten Application 06rect Deck A lication Clay Spanish "S" Tile N/A 0.37 Table 3: Restoring Moments due to - Mg (ft-Ibf) Tile 2":12" 3"•12" 401•12" 510:12" 6":12" 7":12" Profile or Greater Clay Direct Deck Direct Deck Direct Deck Direct Deck f Direct Deck Direct Deck Spanish "S" 6.46 6.36 6.21 6.01 5.74 5.40 Tile Table 6: Attachment Resistance Expresse as a Moment - Mf(ft-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum hment Profile fiWsistance Clay Spanish 3M 2-Component Foam Roof Tile Adhesive AH-160 63.212 "S" Tile 1 Large paddy placement weight 34.6 grams of 3M 2-Component Foam Roof Tile Adhesive -160 NOA No.: 13-0226.02 MIAMNDAD®COUNTY Expiration Date:03/13/18 Approval Date:03/21/13 Page 3 of 6 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". VERSA SPAIN CE LABEL FOR CLAY SPANISH "S" ROOF TILE (LOCATED ON THE SIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. Mu►MHD NOA No.: 13-0226.02 ® , NEW Expiration Date: 03/13/18 Approval Date: 03/21/13 Page 4 of 6 PROFILE DRAWING 19.5" O 11.3" CLAY SPANISH S ROOF TILE END OF THIS ACCEPTANCE NOA No.: 13-0226.02 rM�MADE COUN rir Expiration Date: 03/13/18 Approval Date: 03/21/13 Page 5of6 GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials.The documentation submitted has been reviewed by Miami-Dade County Product Control Section. GI,I so REFLECTANCE AND THERMAL EM [ ANCI ' t Component Name Initial Aged Initial Aged Solar Reflect u ance Reflectance Reflectance Emmitance Emmitance Index(SRI) 1. Clay Spanish"S" 0.39 Pending 0.83 Pending 41 Tile NOA No.: 13-0226.02 [duMIAMFDA ll COUNTY AM Expiration Date:03/13/18 Approval Date:03/21/13 Page 6 of 6