Loading...
EL-16-146 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-252038 Permit Number: EL-1-16-146 Scheduled Inspection Date: February 03,2016 Permit Type: Electrical - Residential Inspector: Devaney, Michael Inspection Type: Final Owner: LEDESMA, MARCOS Work Classification: Alteration Job Address:46 NE 93 Street Miami Shores, FL 33138- Phone Number (305)495-8880 Parcel Number 1132060130190 Project: <NONE> Contractor: LONGMAN ELECTRIC INC Phone: (305)758-1211 Building Department Comments UNDERGROUND FROM OVERHEAD CONVERSION OF Infractio Passed Comments FPL FEEDER. INSPECTOR COMMENTS False Inspector Comments Passed E� Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid February 02,2016 For Inspections please call: (305)762-4949 Page 28 of 42 te,7rrfr NO,' , 53i Miami Shores VillageTf!?flT a E( ;' 'ALM NAM&AN19,11" YPrltal- Id at .. 10050 N.E.2nd Avenue NE IAllorklaSsrtl 1itl�ation Miami Shores,FL 33138-0000 Ro D Phone: (305)795-2204_. CORN v' 1121Expiration: 07/18/2016 Project Address Parcel Number Applicant 46 NE 93 Street 1132060130190 MARCOS LEDESMA Miami Shores, FL 33138- Block: Lot: Owner Information Address Phone Cell MARCOS LEDESMA 46 NE 93 Street (305)495-8880 MIAMI SHORES FL 33138- 46 NE 93 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 1,200.00 LONGMAN ELECTRIC INC (305)758-1211 Total Sq Feet: 0 Type of Work:UNDERGROUND FROM OVERHEAD CONVERSIO Available Inspections: Additional Info: Inspection Type: Classification:Residential Review Electrical Scanning:3 Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $1,20 DBPR Fee InVOICe# EL-1-16-58383 $2.25 01/19/2016 Credit Card $50.00 $116.70 DCA Fee $2,25 Education Surcharge $0.40 01/20/2016 Credit Card $ 116.70 $0.00 Permit Fee-Additions/Alterations $150.00 Scanning Fee $9.00 Technology Fee $1.60 Total: $166.70 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,I authorize the above-named contractor to do the work stated. (/��, , January 20, 2016 Authorized Signature:Owner / Applicant V Contractor / Agent Date Building Department Copy January 20,2016 1 Miami Shores e Villa g • �� Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 T_ FBC 20 BUILDING Permit No. PERMIT APPLICATION Master Permit No. Permit Type: Electrical JOB ADDRESS: ' (h A� gsxd _5-7-XE;� r City: Miami Shores County: Miami Dade Zip. -3 3 Folio/Parcel#: —elg—elfo' Is the Building Historically Designated: Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): � G�rJ�� Phone#: Address: 1®® ' N� 5?_�51CA City: IV 14,Vf "441 e-S State: Zip:,�/ Tenant/Lessee Name: IV/4 Phone#: A Email: GtYC�,�, CONTRACTOR:Company Name: �L�G�j�/� � Phone#: Y44 ' O�e',O Address: /46� /A/-"W City: State: '00Q Zip: Qualifier Name: Phone#: State Certification or Registration#: �����®���� Certificate of Competency#: Contact Phone#: Email Address: fG�� '41"f���L7Y��� ��fd�O�E%• DESIGNER: Architect/Engineer: 00"/X Phone#: Value of Work for this Permit: $ Sal�ai�l' Square/Linear Footage of Work: Type of Work: ❑Address ®® Alteration�a ❑New ❑Repair/Replace ❑Demolition Description of ork: C��I' `/Y�U�`C O/�� � ©7-' �cc Submittal Fee$ 50 Permit Fee$ �.y��i �� CCF$`r° ®_ CO/CC$ Scanning Fee$ . Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ 1 . 00 Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ 4 Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in go faith that a copy of the notice of commencement and construction lien law brochure will he delivered to the person whose grope , subject to attachment. Also, a certified copy of the recorded notice of commencement must he posted at the job site for the first ' sp tion which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection w 1 not e approved and a reinspection fee will he charged. Signature Signature Owner or Agent Contractor i The forego' instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of. ,20 ,by A 5 L&067SM.4 day of.Tf]iV 20 oL,by �IG�7Cf who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: "OV4" JESUSGueALEZ NOTARY PUBLIC: ti * My COMMISSION#FF 011861 EXPIRES:May 20,2017 Sign: 0'060-141 8ondedTMueuagetNotul+Senka Sign: II 1- Prin. (d5 �A Z__ Print: (G Ail C.l 11 e- Y e Z My Commission Expires: PJ– ® — �7 6) /'1 My Commissi E 4PB Notary Public State of Florida ;� Michelle Perez +� My Commission FF 000321 Expires 04/08/2017 APPROVED BY 125:� Plans Examiner Zoning Structural Review Clerk (Revised 3112/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) 46 NE 93rd street Miami SHores, FL 33138 LOAD CALCULATION 2500 sq ft x 3 VA 7500 Small Appliance 3000 Laundry 1500 Dishwasher 1200 Microwave 1200 Dryer 5000 Refrig 1000 Stove 10000 Water Heater 4500 34900 -10000 24900 10000 x 40% 9960.00 9960.00 19960 10000 air conditioning 29960 full VA 34160 / 240 = 124.8333 amperage Longman Electric EC 13003713 844 NE 98 Street Miami, FL 33138 46 NE 93rd street Miami SHores, FL 33138 LOAD CALCULATION 2500 sq ft x 3 VA 7500 Small Appliance 3000 Laundry 1500 Dishwasher 1200 Microwave 1200 Dryer 5000 Refrig 1000 Stove 10000 Water Heater 4500 34900 -10000 24900 10000 x 40% 9960.00 9960.00 19960 10000 air conditioning 29960 full VA 34160 / 240 = 124.8333 amperage Longman Electric EC 13003713 844 NE 98 Street Miami, FL 33138 Ledesma 46 NE 93rd Street Miami Shores,FLS 33138 Longman Electric ' • •a•• EC13003713 i ••• •••'• sees•• _r sees•• • sees•• • • i/�a� • sees•• �" sees sees•• (3) 2/0 THHN's 2" PVC ...... •e .. .. •ase •.•... • e .....• ease% .. . ...... to • 200 Amp NEMA 311 Meter 200 Amp 22KAIC Panel 1 Phase 22KAIC 0 120/240 Volt Ground Bridge #4 Ground i I FPL 2" PVC f =` Underground 5/8" ground rods Cold Water Pipe #4�rourid I _