Loading...
ELC-15-1692 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-238505 PermitNumber: ELC-7-15-1692 Scheduled Inspection Date: January 06,2016 Permit Type: Electrical -Commercial Inspector: Devaney, Michael Inspection Type: Final Owner: SCHOOL INC, MIAMI COUNTRY DAY Work Classification: Repair Job Address:10653 NE 6 Avenue Miami Shores, FL 33138- Phone Number (305)759-2843 Parcel Number 1122310120010 Project: <NONE> Contractor: DDC FIRE ALARM CONSULTING CO Phone: (305)828-3133 Building Department Comments REPLACEMENT OF FIRE ALARM SYSTEM CPU BOARD Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed E�r_ Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid January 05,2016 For Inspections please call: (305)762-4949 Page 9 of 35 Permit NO. ELC-7-15-1692 Miami Shores Village Permit Type:Electrical-Commercial 10050 N.E.2nd Avenue NE e r m Work Classification:Repair Miami Shores,FL 3313&0000 PPermit Status:APPROVED Bd� Phone: (305)795-2204 Expiration: 01/09/2016 Issue Date:7/13/2015 Project Address Parcel Number Applicant 10653 NE 6 Avenue 1122310120010 MIAMI COUNTRY DAY SCHOOL Miami Shores, FL 33138- Block: Lot: 1 &2 Owner Information Address Phone Cell MIAMI COUNTRY DAY SCHOOL INC 601 NE 107 ST (305)759-2843 MIAMI FL 33161-7165 Contractor(s) Phone Cell Phone Valuation: $ 3,180.00 DDC FIRE ALARM CONSULTING CO (305)828-3133 Total Sq Feet: 00 Type of Work:REPLACEMENT OF FIRE ALARM SYSTEM CP Available Inspections: Additional Info: Inspection Type: Classification:Commercial Final Scanning:3 Review Electrical Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $2.40 Invoice# ELC-7-15-56256 DBPR Fee $225 07/13/2015 Check M 334 $ 113.90 $50.00 DCA Fee $2.25 Education Surcharge $0.80 07/07/2015 Check*0327 $50.00 $0.00 Permit Fee $150.00 Scanning Fee $3.00 Technology Fee $3.20 Total: $163.90 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zonin Futhermore,I authorize the above-named contractor to do the work stated. July 13,2016 Authorized Signature:Owne / 'Applicant / Contractor / Agent Date Building Department Copy July 13,2015 1 r CP1TVFD Miami Shores Village JuL072015 g Building Department BY: 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 fh FBC 201Lj'' BUILDING Master Permit No.Z,06 /5 M92, PERMIT APPLICATION Sub Permit No. ❑BUILDING 0 ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 10653 NE 6th Avenue City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:1122310120010 Is the Building Historically Designated:Yes NO Occupancy Type: SG7m'Office Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder):Miami Country Day School Phone#a J---h55" S5(-,c'`7�7 Address:601 NE 107th Street City: North Miami State: Florida Zip: 33166 Tenant/Lessee Name: Phone#: Email: ,� � aa CONTRACTOR:Company Name: DDC Fire Alarm Consulting, Co. Phone#:;2� 3:;>6 Address: 461 West 42nd Place City: Hialeah State: Florida Zip: 33012 Qualifier Name: Lamberto Delgado Phone#: 305-828-3133 State Certification or Registration M EF#20000768 Certificate of Competency M DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$3,180.00 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ■❑ Repair/Replace ❑ Demolition Description of Work: Replacement of fire alarm system CPU mother board Specify color of color thru tile: Submittal Fee$� Permit Fee$. CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ ^^ll TOTAL FEE NOW DUE$ I V (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address 0 City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature / Sign OWNER or AGENT CONTRACTO " Thome foregoing instrument as acknowledged before me this The foregoing instru—meen!t was acknowledged before me this I ay of 20 by day of cJLJ(��J 20 15 by Hlcu�� c� who is personal) own to �CA t�^� �"C� ,Qhd is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY P BLIC: NOTARY PUBLIC: Sign: Sign:_A"A Print• Print e` Seal: s Nolwy pow-8hte of Nedde Seal: MY COMMISSION#EE882s14 �Q, ion;...• ;vs My COM. AV20,2017 •=!!f:��p?�' EXPIRES May 5,2017 Canpdwo I EE 982178 801 III ��• (407)39&0153 FloA .c deNotaryServlceom APPROVED BY J'L/�Y40 Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) RICK SCOTT;GOVERNOR KEN LAWSON,SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD 4� EF200007M �R The ALARM SYSTEM CONTRACTOR I ' Named below IS CERTIFIED ' o Vii the provisions of Chapter 489 FS. Expiration dater AUG 31,2016 DELGADO, LAMBERTO = e® DDC FIRE ALARM CONSULTING CO 461 W 42ND PLACE = HIALEAH FL 33012 F . oa ISSUED: 07/21/2014 DISPLAY AS REQUIRED BY LAW SECT# L1407210001203 City of Hialeah s m Business Tax Receipt ®1 5 �aePB6A�4. Mayor Carlos Hernandez No: 238210-220 (OLD-1711-982) Amount: $ 150.00 The person,firm or corp.listed here has paid the business tax required to engage in or operate the business specified subject to the regulations and restrictions of the City of Hialeah,Florida Owner.LAMBERTO DELGADO Type of Business:Electrical Contractors and Other Wiring Installation Contractors DDC FIRE ALARM CONSULTING CO. Business Location: 461 W 42 PL HIALEAH, FL 33012 461 W 42 PL Validating No.: 344059 Expires September 30,2015 THIS IS 1VOT A BILL Local Business Tax RUCelp i Miami-Dade County, State of Florida { —THIS IS NOTA BILL — DoNOTPAY s 4, 6328033 L_BT _ sy- BuStNESs NAaeS"r_^.nC" `%ECMPT No. - EXPIRES DDC RRE ALARM CONSLILIINS CO 461 w 42 PC ElhlEINAL SEPTE-M 30 20315 6594643 � r HIALEAH FL 33012 Must i displayed at place of business' Pursuant to County CodeJu , I Chapter BA—Ait tl&10 rpet« x: y.j p a { yo CUMER SEC.TYPE-or BUSINESS DDC FIRE ALARM CONSULTING CO 196 SPEC ELECTRICAL CONTRACTOR PAYMENT RECEIVED EF200D0768 By rax COILLEcroR Worker(s) t $45.00 08/28/2014 , = CREDITCARD-14-034170 This I"Basiw=Tax Receipt only conom paymmd of the toai Buslun Tax.The Receipt is nota license. - permit er a cehtirrcatoa of the holtier'squaGricatioas,ba do business Holder now comply with any goveromairw or nomw aramental regaletory laws and rogoiromeats which apply to the business. The RECEIPT Rio.above mast be displayed on at connm rcial vebioles-Mlaml-bade CWO Sec 8a—Z76 s w For mare inlormation,vi* ,eliamamkbWo gpekaxr�Rpestor , DATE(MM/DD/YYY1) AC40R V CERTIFICATE OF LIABILITY INSURANCE 7/7/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Christine Joseph Keen Battle Mead & Company PHONE -1101(30$)558 No c(305)822-4722 7850 Northwest 146th Street E-MAIL DDRESS:c h@kbmco.com Aoaep Suite 200 INSURERIS)AFFORDING COVERAGE NAIC# Miami Lakes FL 33016 INSURERA:Scottsdale Insurance Co INSURED INSURER B$rid efield Employers Ina Co DDC Fire Alarm Consulting, Co INSURERC: 461 N 42nd Place INSURERD: INSURER E Hialeah FL 33012 INSURER F: COVERAGES CERTIFICATE NUMBER:15/16 gl 6 we REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSLTR TYPE D TYPE OF INSURANCE R POLICY NUMBER MMMIUDD1 EFF POLICY LILY EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 A CLAIMS-MADE �OCCUR D AGE TO RENTED 100,000 PREMISES Ea occurrence) $ CPS2220965 7/2/2015 7/2/2016 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 K POLICY PRO LOC JECT PRODUCTS-COMP/OP AGG $ 1,000,000 OTHER: Errors&Omissions $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per acrid nt UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PER O - AND EMPLOYERS'LIA&CITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 100,000 OFFICER/MEMBER EXCLUDED? N 1 A B (Mandatory In NH) 083039509 7/2/2015 7/2/2016 E.L.DISEASE-EA EMPLOYEE $ 100,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached H more space Is required) Electrical Contractor License #EF2000768 Certificate Holder is listed as Additional Insured with respects to General Liability Only. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village Hall THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 NE 2nd Avenue ACCORDANCE WITH THE POLICY PROVISIONS. Miami Shores, FL 33138 AUTHORIZED REPRESENTATIVE Frank Gowin/CJ ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INS025 r9nunil Miami COUNTRY DAY SCHOOL June 29, 2015 Miami Shores Village Building Department Re: Gary T. Butts, Authorized Signer To Whom It May Concern: This is to confirm that Gary T. Butts, Chief Operating Officer of Miami Country Day School is an authorized signer on behalf of the organization. Sincerely, C. (�vL- Christopher Bellows, President Board of Trustees Miami Country Day School, Inc. I'2 q I I Lhvi n a u-e-:v a S • �►Com.E*M04f20.M? CaTab"iEEW17b Bo�eO Thro�111Mi1W MIy1/a1s. 601 Northeast 107 Street I Miami, Florida 33161 1305.759.2843 I Fax 305.759.4871 1 www.miamicountryday.org Every Student.Every Day. it by Entity Name Page 1 of 3 g Y 'n 4 � Detail by Entity Florida Not For Profit Corporation MIAMI COUNTRY DAY SCHOOL, INC. aline Information Eocument Number 744085 FEI/EIN Number 591278987 Date Filed 08/31/1978 State FL Status ACTIVE last Event REINSTATEMENT Event Date Filed 10/21/2010 + ial Address ! 601 N.E. 107TH STREET MIAMI, FL 33161 Changed: 10/21/2010 ailingAddress ,101 N.E. 107TH STREET MIAMI, FL 33161 --hanged: 01/17/2012 Registered Agent Name &Address DAVIES, JOHN 601 N.E. 107TH ST MHAMI, FL 33161 isiame Changed: 05/18/2009 i address Changed: 05/18/2009 ii fiver/Director Detail Name &Address Title DP i HRISTOPHER, BELLOWS 134 NE 102 STREET � MIAMI SHORES, FL 33138 hctp://search.sunbiz.org/Inquiry/CorporationSearc:h%SearchResultDetail?inquirytype=Entity... 7/7/2015 Dt it by Entity Name Page 2 of 3 Title DS LAZENBY, MATTHEW 531 W 51 ST STREET MIAMI BEACH, FL 33140 Title DT FARREY, JOHN F 1315 BAY TERR N BAY VILLAGE, FL 33141 Title COO BUTTS, GARY T 601 NE 107 ST MIAMI, FL 33161 Title 1 VP PREMER, HOWARD x_010 NE 120 ROAD NORTH MIAMI, FL 33181 Tile 2VP MOORE, JAMES 5005 NORTH BAY ROAD MIAMI BEACH, FL 33140 ,annual Reports j Report Year Filed Date 2013 02/22/2013 2014 02/25/2014 2015 02/26/2015 Document Irma�e� 02/26/21015 --ANNUAL REPORT _View image in PDF format ) ? 5/2014 --ANNUAL REPORT View image in PDF format 02/22/2013--ANNUAL REPORT View image in PDF for 01111/2012 ANNUAL REPORT View image in PDF format 01/04/2011 --ANNUAL REPORT view image in PDF format 1.0112.1.12010 -- REINSTATEMENT View image in PDF format 0.5/18/2009 Req. Agent Change View image in PDF format 04/1.4/2009 -- ANNUAL REPORT View image in PDF format 1 105/2008 -- Reg. Agent Change L_ View image in PDF format 04/30/2008 --ANNUAL REPORT j View image in PDF format http:/,/search.sunbiz.org/Inquiry/CorporationSearc hi SearchResultDetail?inquirytype=Entity... 7/7/2015 NFS-320(E) EE7a�'_>-7112:G NOTIFIER Intelligent Addressable Fire Alarm System by Honeywell General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® #!"l lip,Series of Fire Alarm Controls from NOTIFIER. 1( I Illl 9 In stand-alone or network configurations,ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. - - The panel can be configured with just a few devices for small building applications,or networked with many devices to protect , < a large campus or a high-rise office block.Simply add additional � rij� VII peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series 'e s annunciator can be mounted in the same cabinet (up to 48 E zones/points,order separately;see DN-60085). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT2UD permit monitoring of alarm signals over the Internet,saving the monthly cost of two dedicated business tele- NFS-320 phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. • Alarm Verification selection per point,with tally. NOTE:Unless called out with a version-specific R" C"or E"at • Presignal/Positive Alarm Sequence(PAS). the end of the part number, "NFS-320"refers to models NFS-320, . Silence inhibit and Auto Silence timer options. MFS-320R,NFS-320C,and NFS-320E. • NAC ceding functions: Features -March time. -Temporal. • Certified for seismic applications when used with the appro- -California two-stage coding. priate seismic mounting kit. • Approved for Marine applications when used with listed com- -Canadian two-stage. •.... • • -Strobe synchronization. • • .... patible equipment(see DN-60688). • . . .....• • • Field-programmable on panel or&?PC!with V*QRre%TboIS • a One isolated intelligent Signaling Line Circuit(SLC)Style 4,6 r ram check,compare,simulate.... so: •. or 7. program Pa . ....•. • Up to 159 detectors(any mix of ion,photo,thermal,or multi- • Full QWERTY keypad. ••.... • • • sensor) and 159 modules (Addressable pull stations, nor- • Battery charger supports 18-200#ibatteries.00.• :so**: malty open contact devices,two-wire smoke, notification, or • Non-alarm points for lower priority kxwt*ons. •....' ••••• relay).318 devices maximum. • Remote ACK/Signal Silence)Sl9tp•Reset/Dr;d6 via ryonitor•• ••• • Standard 80-character display. modules. .. .. ••o ...... • Network options: • Automatic time control functions,owiih.holiday exceptions. . -High-speed network for up to 200 nodes (NFS2-3030, • Extensive,built-in transient proiection.: . • •• NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, . Powerful Boolean logic equaticTs. •.• ;•'•'• ••••• ONYXWorks,NFS-3030,NFS-640,and NCA). -Standard network for up to 103 nodes(NFS2-3030,NFS2- FLASHSCAN®INTELLIGENT FEATURES.- ;•; ••••• 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX- . Poll up to 318 devices in less than two seconds• Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- . Activate up to 159 outputs in less than five seconds. 300/400, AFP-1010, and AM2020). Up to 54 nodes when Multicolor LEDs blink device address Burin Walk Test. DVC is used in network paging. • 9 • 6.0 A power supply with four Class AB built-in Notification • Fully digital,high-precision protocol(U.S.Patent 5,539,389). Appliance Circuits (NAC). Selectable System Sensor, • Manual sensitivity adjustment—nine levels. Wheelock,or Gentex strobe synchronization. • Pre-alarm ONYX intelligent sensing—nine levels. • Built-in Alarm,Trouble,Security,and Supervisory relays. • Day/Night automatic sensitivity adjustment. • VeriFireO Tools online or offline programming utility. Upload/ • Sensitivity windows: Download, save, store, check,compare, and simulate panel -ton-0.5 to 2.5%.400t obscuration. databases.Upgrade panel firmware. -photo-0.5 to 2.35%/foot obscuration. • Autoprogramming and Walk Test reports. -Laser(VIEW@)-0.02 to 2.0%/foot obscuration. • Optional universal 318-point DACT. -Acclimate0 PlusTm 0.5 to 4.0%/foot obscuration. • 80-character remote annunciators(up to 32). -IntelliQuad-1.0 to 4.0%Aoot obscuration. • EIA-485 annunciators,including custom graphics. -IntelliQuadTm PLUS-1.0 to 4.0%/foot obscuration • Printer interface(80-column and 40-column printers). Drift compensation(U.S.Patent 5,764,142). • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. DN-7112:G•12/1912011—Page 1 of 6 J - • Degraded mode—in the unlikely event that the NFS-320's FSC-851 INTELL/QUAD primary microprocessor fails, FlashSoan detectors revert to ADVANCED MULTI-CRITERIA DETECTOR degraded operation and can activate the control panel's NAC circuits and alarm relay.Each of the four built-in panel circuits • Detects all four major elements of a fire (smoke, heat, CO, R - includes a Disable/Enable switch for this feature. and flame). • Multi-detector algorithm involves nearby detectors in alarm • Automatic drift compensation of smoke sensor and CO cell. decision(U.S.Patent 5,627,515). • High nuisance-alarm immunity. • Automatic detector sensitivity testing(NFPA-72 compliant). • Six sensitivity levels. • Maintenance alert(two levels). FCO-851 INTELLIQUADrm PLUS • Self-optimizing pre-alarm. ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR FSL-751 VIEW(VERY INTELLIGENT EARLY WARNING) . Detects all four major elements of a fire. SMOKE DETECTION TECHNOLOGY • Separate signal for fife-safety CO detection. • Revolutionary spot laser design. • Optional addressable sounder base for Temp-3 (fire) or • Advanced ONYX intelligent sensing algorithms differentiate Temp-4(CO)tone. between smoke and non-smoke signals (U.S. Patent . Automatic drift compensation of smoke sensor and CO cell. 5,831,524). • High nuisance-alarm immunity. • Addressable operation pinpoints the fire location. • Six sensitivity levels. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration RELEASING FEATURES systems at a fraction of the lifetime cost. Ten independent hazards. FAPT-851 ACCLIMATEO PLUS"" • Sophisticated cross-zone(three options). LOW-PROFILE INTELLIGENT MULTI-SENSOR • Delay timer and Discharge timers(adjustable). • Detector automatically adjusts sensitivity levels without oper- • Abort(four options). ator intervention or programming. Sensitivity increases with • Low-pressure CO2 listed. heat. • Microprocessor-based technology; combination photo and VOICE FEATURES thermal technology. • Integrates with FireVoice-25/50 Series(see DN-7004). • FlashScan or CLIP("classic')mode compatible. • Integrates via serial connection with FireVoice-25/50ZS • Low-temperature warning signal at 40T t 5°F (4.44°C * Series(see DN-7003). 2.77°C). HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY(6.0 A IN ALARM) •••• • 120 VAC(NFS-320/NFS-320C);240 VAC(NFS-320E). ..•••• •0000 .'• : • Displays battery current/voltage on panel(with display). • . ••• • •• • • • UP to 32�j•• • •••• •••••• •• Remote • • Displays*••••• SLC Intelligent Loop • • flCD21-1VVLC •� •• -- - DEVICES- o 0 • • •• FSC-851 IAcdm to°1 ••••• • FAPT-851 AccBmate PIusTM FSL-751 Flash&"VIEM NBC-12LX FMM-1 FRM-1 XP6J10 : •••FDU�80 FSP-851 FlashScanG phaco 110 Modules �• IDC Relay Contact • • • • • • • • EIA-485 •••••• ••• • • •• EIA-485 2048 annunciator/control points ACM-8R ACM/AEM-24AT LOM-32 NFS320 Relay Control LED Annunciator Custom Graphics Optional 318 point UDACT Dual phone lines to lb Central Station Sample System EIA-232 0 Options PRN Series Printer rttabbk.wmf Page 2 of 6—DN-7112:0.12/19/2011 FlashScan, Exclusive own program, including control-by-event links to other points. World-Leading Detector Protocol This allows the program to be entered with independent per- point segments, while the NFS-320 simultaneously monitors At the heart of the NFS-320 is a set of detection devices and other(already installed)points for alarm conditions. device protocol—FlashScan (U.S. Patent 5,539,389). RashS- VeriFire®Tools is an offline programming and test utility that can can is an all-digital protocol that gives superior precision and greatly reduce installation programming time,and increase con- high noise immunity. fidence in the site-specific software. It is Windows®-based and In addition to providing quick identification of an active input provides technologically advanced capabilities to aid the device,this new protocol can also activate many output devices installer. The installer may create the entire program for the in a fraction of the time required by competitive protocols.This NFS-320 in the comfort of the office,test it,store a backup file, high speed also allows the NFS-320 to have the largest device then bring it to the site and download from a laptop into the per loop capacity in the industry—318 points—yet every input panel. and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs Placement of Equipment that can be coded to provide diagnostic information, such as in Chassis and Cabinet device address during Walk Test. The following guidelines outline the NFS-320's flexible system ONYX Intelligent Sensing design. Intelligent sensing is a set of software algorithms that provides Wiring:When designing the cabinet layout,consider separation the NFS-320 with industry-leading smoke detection capability. of power-limited and non-power-limited wiring as discussed in These complex algorithms require many calculations on each the NFS-3201nstallation Manual. reading of each detector, and are made possible by the high- It is critical that all mounting holes of the NFS-320 are secured speed microcomputer used by the NFS-320. with a screw or standoff to ensure continuity of Earth Ground. Drift Compensation and Smoothing: Drift compensation Networking:If networking two or more control panels,each unit allows the detector to retain its original ability to detect actual requires a Network Control Module or Highspeed Network smoke, and resist false alarms, even as dirt accumulates. It Control Module (HS-NCM can support two nodes; see "Net- reduces maintenance requirements by allowing the system to working Options"on page 4).These modules can be installed in automatically perform the periodic sensitivity measurements any option board position (see manual), and additional option required by NFPA 72. Smoothing filters are also provided by boards can be mounted in front of them. software to remove transient noise signals, such as those caused by electrical interference. KDM-R2 Controls and Indicators Maintenance Warnings: When the drift compensation per- program Keypad-QWERTY type(keyboard layout). formed for a detector reaches a certain level,the performance of the detector may be compromised, and special warnings are 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; given.There are three warning levels: (1)Low Chamber value; Supervisory; System Trouble; Signals Silenced; Points Dis- (2) Maintenance Alert, indicative of dust accumulation that is abled;Control Active;Abort;Pre-Discharge;Discharov,• near but below the allowed limit;(3)Maintenance Urgent,indica- Keypad Switch Controls: AcknourledgelScroll Dts"V; Signal tive of dust accumulation above the allowed limit. Silence;Drill;System Reset;Lamp'fezte ; G o• • Sensitivity Adjust: Nine sensitivity levels are provided for LCD Display: 80 characters (2 x 400 with long-life LRQ.%ack- �• alarm detection. These levels can be set manually, or can light. •..;0 0 •••••• change automatically between day and night.Nine levels of pre- ' �V696: alarm sensitivity can also be selected,based on predetermined •see* •••• levels of alarm. Pre-alarm operation can be latching or self- Ordering Information ...•• 0 0 "see restoring,and can be used to activate special control functions. • "Configuration Guidelines"on pag e ll• ••• • .*;6 6• Self-Optimizing Pre-Alarm:Each detector may be set for"Self- • "Networking Options"on page 4• •• �•; Optimizing" pre-alarm. In this special mode, the detector • "Auxiliary Power Supplies and gdt&ieg'on page 4• • "learns" its normal environment, measuring the peak analog • "Audio Options"on page 4 • • • • 0 0 00:0 readings over a long period of time, and setting the pre-alarm * •••••• level'est above these normal alts. "Compatible Devices,EIA-232 jbort�br page 4 . 0 i • "Compatible Devices,EIA-485 PBAs"dh page 4•• 9 ;•"'; Cooperating Multi-Detector Sensing: A patented feature of "Compatible Intelligent Devices"on page 4 •• • ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre- • "Enclosures,Chassis,and Dress Plates"on page 5 alarm decisions. Without statistical sacrifice in the ability to • "Other Options"on page 5 resist false alarms,it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. CONFIGURATION GUIDELINES The NFS-320 system ships assembled,description and some Field Programming Options options follow. See Enclosures, Chassis,and Dress Plates"on Autpage 5 for information about mounting peripherals. tine. The FAC This timesaving feature is a special software coed NOTE:Stand-alone and network systems require a main display. tine. The FACP"learns"what devices are physically connected On stand-alone systems,the panel's keypad provides the required and automatically loads them in the program with default values display. On network systems (two or more networked fire panel for all parameters. Requiring less than one minute to run, this nodes), at least one NCA-2, NCS, or ONYXWorks annunciation routine allows the user to have almost immediate fire protection device is required. in a new installation,even if only a portion of the detectors are installed. NFS-320: The standard, factory-assembled NFS-320 system Keypad Program Edit (with KDM-R2) The NFS-320, like all includes the following components: one control panel mounted bat- NOTIFIER intelligent panels, has the exclusive feature of pro- tery chassis(120 V operation—ships with grounding cable, gram creation and editing capability from the front panel keypad, interconnect cables, and document kit); includes integral power while continuing to provide fire protection. The architecture of power supply mounted to the main circuit board; one primary the NFS-320 software is such that each point entry carries its display KDM-R2 keypad/display;and one cabinet for surface or DN-7112:G s 1211912011—Page 3 of 6 semi-flush mounting.Purchase batteries separately.One or two COMPATIBLE DEVICES,EIA485 PORTS option boards may be mounted inside the NFS-320 cabinet,• ACM-24AT:ONYX Series ACS annunciator-up to 96 points of additional option boards can be used in remote cabinets. annunciation with Alarm or Active LED,Trouble LED,and switch NFS-32OR:Same as NFS-320 above,but in red enclosure. per circuit. Active/Alarm LEDs can be programmed (by pow- NFS-32OC: Based on NFS-320 above. NFS-320C supports Bred-up switch selection)by point to be red,green,or yellow;the installation of an optional ACM-series annunciator in the same Trouble LED is always yellow.See DN-6862. cabinet.UL-and ULC-listed. AEM-24AT: Same LED and switch capabilities as ACM-24AT, NOTE.For additional information on NFS-320C,see DN-60085expands the ACM-24AT to 48,72,or 96 points.See DN-6862. NFS-320E:Same as NFS-320 above,but with 240 V operation. ACM4M:ONYX Series ACS annunciator-up to 96 points of TR-320:Trim ring for the NFS-320 cabinet. annunciation with Alarm or Active LED per circuit.Active/Alarm LEDs can be programmed (by powered-up switch selection) in NETWORKING OPTIONS groups of 24 to be red,green,or yellow.Expandable to 96 points with one AEM-48A. See DN-6862. Wire an NCM-F:Standard Network Communications Modules. AEM-48A: Same LED capabilities as ACM-48A, expands the Wire and multi-mode fiber versions available.See DN-6861. ACM-48A to 96 points.See DN-6862. HS-NCM-W/MF/SF/WMFMISF/MFSF: High-speed network communications modules. Wire, single-mode fiber, multi-mode ACM-8R: Remote Relay Module with eight Form-C contacts. fiber, and media conversion models are available. See DN- Can be located up to 6,000 ft. (1828.8 m) from panel on four 60454 wires.See DN-3558. RPT-W,RPT-F,RPT-WF:Standard-network repeater board with LCD-80: ACS mode. 80-character, backlit LCD display. Mounts wire connection (RPT-W),fiber connection(RPT-F), or allowing up to 6,000 ft. (1828.8 m)from panel. Up to 32 per FACP. See a change in media type between wire and fiber(RPT-WF). Not LCD-801-80TM(DN-3198). used with high-speed networks.See DN-6971. FDU40: Terminal mode. 80-character, backlit LCD display. ONYXWorks:UL-listed graphics PC workstation,software,and Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per computer hardware. See DN-7048 for specific part numbers. FACP.See DN-6820. NFN-GW-EM-3:NFN Gateway,embedded. LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per AUXILIARY POWER SUPPLIES AND BATTERIES FACP. See DN-60548. ACPS-610.6.0 A or 10 A addressable charging power supply. LDM: Lamp Driver Modules LDM-32,LDM-E32,and LDM-R32; See DN-60244. remote custom driver modules.See DN-0551. APS2.6R•Auxiliary Power Supply. Provides up to 6.0 amperes SCS: Smoke control stations SCS-8,SCE-8,with lamp drivers of power for peripheral devices.Includes battery input and trans- SCS-8L, SCE-8L; eight (expandable to 16) circuits. See DN- fer relay,and overcurrent protection.Mounts on two of four posi- 4818• tions on a CHS-4L or CHS-4 chassis.See DN-5952. TM-4: Transmitter Module. Includes three reverse-polarity cir- FC.W24S6/S8• Remote 6 A and 8 A power supplies with bat- cuits and one municipal box circuit; mount on NFS-320 chassis •••••• t6ry c�gr'ger.See 1W-6927. or remotely. See DN-6860. MT Series:Batteries.-AFS-320 uses two 12 volt, 18 to 200 AH UDACT:Universal Digital Alarm Communicator Transmitter,636 .' bpV@ries.See D&eW8a channel.See DN-4867. •••••• AUB/O OPTION$•'•• UDACT 2: Universal Digital Alarm Communicator Transmitter, • •• 0000 636 channel.See DN-60686. • • NfV','ft: 25 watt, 25•VRMS, emergency Voice Evacuation •• UZC-256: Programmable Universal Zone Coder provides posi- ••• •• CoRifdl'Panel(VECP)w fth integral commercial microphone,dig- tive non-interfering successive zone coding. Microprocessor- ital memage geti&F4 F, and single-/dualchannel Class A or controlled, field-programmable from IBM®-compatible PCs •••••• CW1 B speaker civmits.•See DN-7004. (requires optional programming kit). Mounts in BB-UZC. See •• NFV-25f50DA:Sir!Ir'dhDnnel, 25 Watt,25 VRMS, emergency DN-3404. • voi(;p evaruation panel.See DN-60048. COMPATIBLE INTELLIGENT DEVICES • . NP0&NDAZS:9iggle Channel,25 Watt,25 Vrms,emergency ••••• vow.evacuation panei!Can be automatically activated via the BEAMHK: Heating kit for transmitter/receiver unit of ' Zdre'SA*m serial communication link from the NFV 25/50ZS. FSB-200(S)below.See DN-6985. See DN-60049. BEAMHRK:Heating Idt for use with the reflector of FSB-200(S) NFV 25/50ZS: 25 waft, 25 Vrms, emergency Voice Evacuation below.See DN-6985. Control Panel(VECP)with integral commercial microphone,dig- BEAMLRK• Long-range accessory kit, FSB-200(S) below. See ital message generator,zone splitter module(ACC-ZSM),zone DN-6985. page module with keypad(ACC-ZPMK).See DN-7003 BEAMMRK:Multi-mount kit,FSB-200(S)below.See DN-6985. NFV-25/50ZST:25 watt,25 Vrms,emergency Voice Evacuation BEAMSMK• Surface-mount kit, FSB-200(S) below. See DN- Control Panel(VECP)with integral commercial microphone,dig- 6985. ital message generator,zone splitter module(ACC-ZSM), zone page module with keypad(ACC-ZPMK).See DN-60337. FSB-200:Intelligent beam smoke detector. See DN-6985. COMPATIBLE DEVICES,EIA-232 PORTS FSB-20OS: Intelligent beam smoke detector with integral sensi- tivity test.See DN-6985 PRN-6:80-column printer.See DN-6956. FSC451:FlashScan IntelliQuad Advanced Multi-Criteria Detec- VS409515: Printer,40-column, 24 V. Mounted in external back- tor.See DN-60412. box.See DN-3260. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Criteria DPI-232:Direct Panel Interface,specialized modem for extend- Fire/CO Detector. See DN-60669. ing serial data links to remotely located FACPs and/or peripher- FSI-851: Low-profile FlashScan ionization detector. See DN- - als;mount on NFS-320 chassis.See DN-6870. 6934 Page 4 of 6-DN-7112:0•12/19/2011 FSP-851: Low-profile FlashScan photoelectric detector. See SEISVJT 320IB26: Seismic mounting kit. Required for seismic- DN-6935, certified applications with NFS-320 and BB-26.Includes battery FSP-851 T: Low-profile FlashScan photoelectric detector with bracket for two 26 AH batteries. 135°F(57°C)thermal.See DN-6935. SEISKIT BB25: Seismic mounting kit for the BB-25. Includes • FSP-851 R: Remote-test capable photoelectric detector for use battery bracket for two 26 AH batteries. with DNR(W)duct detector housings.See DN-6935. SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery FST-851: FlashScan thermal detector 135°F (570C). See bracket for two 55 AH batteries. DN-6936. SEISK T PSf2/4: Seismic mounting kit for the FCPS-24S6/S8 FST-851R: FlashScan thermal detector 135°F(57°C)with rate- and CAB-PSi. Includes battery bracket for two 7 AH or 12 AH of-rise.See DN-6936. batteries. FST-8511-11: FlashScan 190°F (88°C) high-temperature thermal OTHER OPTIONS detector.See DN-6936. 411:Slave Digital Alarm Communicator.See DN-6619. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor 411 UDAC•Digital Alarm Communicator.See DN-6746. detector.See DN-6937. FSL-751.FlashScan VIEW laser photo detector.See DN-6886. IPDACT 2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports DNR: InnovairFlex low-flow non-relay duct-detector housing for internet communications over customer-provided ethernet (order FSP-851R separately). Replaces FSD-751 PL/FSD- connection. Requires compatible Teldat VisorALARM Central 751 RPL.See DN-60429. Station Receiver.Can use DHCP or static IP.See DN-60408. DNRW: Same as above with NEMA-4 rating, watertight. See IPSPLT:Y adaptor option allow connection of both panel dialer DN-60429. outputs to one IPDACT-2/2UD cable input. B224RB:Low-profile relay base.See DN-60054. IPENC: External enclosure for IPDACT, includes IPBRKT B224BI:Isolator base for low-profile detectors. See ON-60054. mounting bracket;Red.For Black order IPENC-B. B21OLP: Low-profile base. Standard U.S. style. Replaces IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- B710LP.See DN-60054. cator. Provides selectable configurable paths: cellular only, IP B501•European-style,4•(10.16 cm)base.See DN-60054. only,or IP primary with cellular backup.Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See B20OS:Intelligent programmable sounder base,capable of pro- DH-60695. ducing a variety of tone patterns including ANSI Temporal 3. VeriFire-TCD: VeriFire Tools CD-ROM. Contains programming Compatible with sychronization protocol.See DN-60054. software for the ONYX Series. Includes local panel connection B200SR: Sounder base, Temporal 3 or Continuous tone. See cable.See DN-6871. DN-60054. VerlFlreUG-TCD:VeriFire Tools upgrade software. FMM-1:FlashScan monitor module.See DN-6720. NFS-320-RB: Replacement CPU. NOTE: Keypad must be FDM-1:FlashScan dual monitor module.See DN-6720. removed before shipping old unit out for repair. *000 FZM-1: FlashScan two-wire detector monitor module. See DN- • NFS-320-RBE:Replacement EPU,E�port. 666e.0 •••••• 6720. • NFS-320-RBC-FR:Replacemeh?CPlJ,Canadian French. 0• FMM-101:FlashScan miniature monitor module.See DN-6720. . NFS-320-RB-PO:ReplacemAl W, Portuguese!: •••.:. FCM-1:FlashScan NAC control module.See ON-6724. . NFS-320-RB-POE: Replace"W ICPU, Export, Portu- • . FCM-I-REL: FlashScan releasing control module. See DN- guese. •0000 •.•• 000000 ; 60390. • • • • NFS-320-RB-SP:Replacemen101'1;1,Spanish••• ....• FRM-1:FlashSoan relay module. See DN-6724. • NFS-320-RB-SPE:ReplacemerIM,Exp8tT,Wish. --:--o FDRM-1: FlashScan dual monitorldual relaymodule. See DN- •• • 60709. NOTE:For other options including compatibility with retrofft'equip-••••�• ment,refer to the panel's ins1a11atio4?h14i74 the SLC manual,and • NBG-12LX:Manual pull station,addressable.See DN-6726. the Device Compatibility Document! • • . •0•• • ISO-X:Isolator module. See DN 2243. ; 000 •0 • . . XP6-C: FlashScan six-circuit supervised control module. See •• • :••••: pe • .•• DN-6924. ••.• XP6-MA:FlashScan six-zone interface module;connects intelli- gent alarm system to two-wire conventional detection zone.See DN-6925. XP6-R: FlashScan six-relay(Form-C)control module. See DN- 6926. XP10-M:FlashScan ten-input monitor module.See DN-6923. ENCLOSURES,CHASSIS,AND DRESS PLATES MARINE-EQ System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment,see DN-60688. BB-UZC:Backbox for housing the UZC-256. Required for NFS- 320 applications.Black.For red,order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBB:Same as above,but red. DN-7112:G•12/19/2011-Page 5 of 6 r - SYSTEM SPECIFICATIONS System Capacity its peripherals be installed in an environment with a normal room • Intelligent Signaling Line Circuits.........................................1 temperature of 15—27°C/60—80°F. • Intelligent detectors .........................................................159 Agency Listings and Approvals • Addressable monitor/control modules..............................159 • Programmable internal hardware and output circuits ..........4 The listings and approvals below apply to the basic NFS-320 control panel.In some cases,certain modules may not be listed • Programmable software zones...........................................99 by certain approval agencies,or listing may be in process.Con- • Special programming zones...............................................14 suit factory for latest listing status. • LCD annunciators per NFS-320/-320E .............................32 • UL Listed:S635. • ACS annunciators • ULC Listed:S635(NFS-320C only,excludes IPDACT). per NFS-320/-320E .......................32 addresses x 64 points • FM Approved. Specifications • CSFM:7165-0028:0243. • MEA:128-07-E. • Primary input power • FDNY:COA#6085. —NFS-320:120 VAC,50!60 Hz,5.0 A. • City of Chicago. —NFS-320E:220240 VAC,50/60 Hz,2.5 A. NOTE. For additional information on UL- and ULC-listed model • Total output 24 V power:6.0 A in alarm. NFS-3200,see DN-60085. For information on NFS-320SYS,see NOTE: The power supply has a total of 6.0 A of available power. DN-60637. This is shared by all internal circuits. When used with the MARINE-EQ,appropriate seismic bracket, • Standard notification circuits(4): 1.5 A each. and marine approved devices, these ONYX fire alarm control • Resettable regulated 24V power:1.25 A. panels are approved by the following agencies: • Two non-resettable regulated 24V power outputs: • US Coast Guard:161.002/50/0(Standard 46 CFR). —1.25 A. • Lloyd's Register:1100013(ENV 3 category). —0.50 A. • Non-resettable 5V power:0.15 A. Standards • Battery charger range: 18 AH—200 AH.Use separate cabi- The NFS-320 complies with the following UL Standards and net for batteries over 26 AH. NFPA 72, IBC,and CBC Fire Alarm Systems requirements: • Float rate:27.6 V. • UL 864(Fire). .•"•• • • UL 1076(Burglary). •••••• CVvlhet Slecidcations • LOCAL (Automatic, Manual,Waterflow and Sprinkler Super- • • ••• •• viso ry) • •• l fP320 cabinetdigw"ons: Bgckbox: 18.-3-t•(46.025 cm)width; 18.12 in. (46.025 cm) AUXILLARY (Automatic, Manual and Waterflow) {requires •••.: heigljt;5.81 in.('&7.6 cm)depth. TM-4). •• ip.r;•18.187' Vel 95 cm) width; 18.40 in. (46.736 cm) • REMOTE STATION (Automatic, Manual, Waterflow and ••• • Sprinkler Supervisory)(requires TM-4). lig �t`0.75 ins(1� 5•cm)depth. . PROPRIETARY(Automatic,Manual,Waterflow and Sprinkler ••"' •:Trim ring:Moldigg%Ah is 0.905 in.(2.299 cm). •�•��� •• Supervisory).Not applicable for FM. • Shipping weigbt�(�pf#4grt batteries):36.15 Ib.(16.4 kg). . CENTRAL STATION (Automatic, Manual, Waterflow and •� �� • : • : Sprinkler Supervisory)(requires UDACT). •' TenApa�raturp arid Humidity Ranges . EMERGENCY VOICEIALARM. •••••• TIV%System means NEPA requirements for operation at 0 — • OT, PSDN (Other Technologies, Packet-switched Data Net- 490CM? •120°F and at a relative humidity 939/6 t 29/6 RH(non- work). condensing)at 32°C t 2°C (90°F t 30F). However,the useful . IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). life of the system's standby batteries and the electronic compo- . CBC 2007(Seismic). nents may be adversely affected by extreme temperature ranges and humidity. Therefore,it is recommended that this system and NOTI•FIRE•NETT"',Inte111Quad"",and ONYXWorkaTm are trademarks;and AccllmateO Plus1e°, FlashScanS, NOTIFIER®, ONYX®, VerlFIree, and VIEW®are registered trademarks of Honeywell International Inc.MIcrosott® and Windows®are registered trademarks of Microsoft Corporation.IBM®is a registered trademark of IBM Corporation. 02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. we cannot cover all specific applications or anticipate all requirements. 6�Il�fii 8 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-7112:G•12/19/2011 DN-6619:A2•K-95 411 Series NOTIFIER Slave Digital Alarm ' Communicator Transmitters by H o n eywe I I General -177 The 411 Series DACTs are compact, multifaceted, slave Digi- tal Alarm Communicator Transmitters designed for a variety of fire,security,and non-fire applications.The series features the 411 and 411UD, which provide three and four monitoring m channels(inputs)respectively.These slave DACTs are a solu- tion for applications that require an existing(or new)fire alarm control panel (FACP) to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to extremely flexible programming options,the 411 Series slave DACTs are also ideal for monitoring non-fire and security s -r-' • " control panels. With fifteen selectable transmission formats (including ADEMCO Contact ID)compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. $ Programming can be accomplished on-site with a hand-held programmer (PRO-411), or remotely (411UD only) using the PK-411 UD programming utility.This Windows&based remote • Programmable from remote site with optional PK-411UD upload/download software package permits system interroga- programming software(model 411 UD only). tion and revision from a remote site. • View 411 Series status offsite in real time,with optional PK- 411UD programming software, without ever compromising Features monitoring protection at the protected premises (model • Three(411)or four(411 UD)monitoring channels(inputs). 411UD only). • Inputs may be individually programmed to monitor the host • Programming sequence based on NOTIFIER's popular control panel for: SFP-1024 Control/Communicators. —Fire Alarm. • Integral piezo sounder (troth models) with local silence switch(model 411 UD only). —Fire Trouble. • One Form-C relay,fully programmable(model 411UD only). —Fire Supervisory. **so • Complies with NFPA 72 (Central Station and•Remote Sta- -Process Monitoring. tion(DACT only-not polarity rd�p&A1Jfire Alarm Systems). •'•••• —AC Power Loss. • Surface Mount Technology(S •Y• : o �T•)•••• •o o• —Security Alarm. . *agog* _ tY Extremely compact enclosu�.��suring o�ly 6.75 —Other(Fire and Non-Fire Events). (17.145 cm)W x 4.40'(11.176 gry�F�x 1.05°{�.6 cm)D. *Goes* • Fully supervised trigger inputs require a contact closure for • Shares identical footprint with'$1,1.$gries fot12 rl�aement a activation. purposes. •••••• • • 000000• 0 12-or 24-VDC operation,jumper-selectable. •.•..• ••• • • Industry-first, UL recognized, "dialer-runaway" prevention Host Panel Compatilffitg. feature. Host panels must include AC FJI Dela;optionjo mgpt NFPA �• • Dual-line,rotary or touch-tone-dial DACT interfaces to pub- Central Station Requirements. Panels pith this Vlre 4nolude•*see lic switched telephone network(leased phone lines are not RP-1001, RP-1002, RP-2001, F3%;002:System 500, System;••..; required). 5000, AFP-200, AFP-300, AFP-400, NFS-32t,:119S-640! • • Includes 15 reporting formats, including the popular NFS2-640,AFP1010,AM2020,NFS-3030,and RIVS2-8030. ADEMCO Contact ID format. • Capable of transmitting the following DACT information, in Housing addition to vital system status of the host control panel: The 411 Series DACTs are fully enclosed in a compact Nous- -DACT troubles. ing measuring only 6.75'(17.145 cm)W x 4.40°(11.176 cm)H —Telephone line 1 and 2 voltage fault. x 1.05° (2.667 cm) D. The housing enclosure consists of an —Primary or Secondary Central Station communication aluminum backbox painted red with a matching cover secured fault. by two captive screws. The overlay includes large areas to independently mark programming options for the three or four —System off-normal. channels(inputs),relay,and also includes printed terminal and —24-hour normal test. diagnostic LED designations.The overall compact size of the —24-hour abnormal test. enclosure permits mounting of these DACTs in virtually any ~ Long distance Carrier Access Code (CAC) compliant, control panel's enclosure, or alternately, adjacent to the host • control panel. accepting up to 20-digit Central Station telephone numbers. • Fully programmable transmittal lodes for fire,security, pro- Phone Line Connections ' cess monitoring,and others. • Field-programmable with PRO-411 hand-held programmer. Two modular phone connections on the 411 Series are acces- sible with the cover in place and provide connections for two DN-6619:A2.4/1 31201 2—Page 1 of 4 separate telephone lines using standard RJ31X or RJ38X Specifications— 411 y jacks. Both telephone lines are constantly supervised for proper operation and integrity.If one phone line goes into fault FCC Registration: OAAUSA-25431-AL-E. Ringer Equiva- while the other is working, a report is sent to the central or lence:0.5 B. remote station. For Canadian Applications: IC Certificate Number: 2132 9028 A.Ringer Equivalence Number(REN):0.2. Diagnostic LEDs Programming: A digital programming unit with a keypad, • Communication Fail(visible with front cover in place). model PRO-411,is available for programming the 411 Series. • DACT Trouble(visible with front cover in place)(411 UD). Operating Power: The 411 may be powered from UL-listed • Channel Active(visible with front cover in place)(411 UD). control panels that output nonresettable and power-limited 12 or 24 VDC power.The configuration of Jumper J4 determines • Primary Phone Line Active(411 UD). whether 12 VDC power is to be supplied directly to the 411 cir- • Secondary Phone Line Active(411UD). cuit board,or 24 VDC power is to be supplied and then inter- • Modem Active(411UD). nally regulated down to 12 VDC. DC Power:TBI Terminals 1(+)and 2(–);Terminal 3 is Earth Specifications —411 UD Ground. Listings and Approvals: J4 Jumper removed:Filtered,nonresettable,and power-lim- • NFPA 72:Central Station Fire Alarm Systems. ited 24 VDC (nominal) power must be supplied at TBi Ter- minals 1(+) and 2(–). Operating voltage provided must be • NFPA 72:Remote Station Fire Alarm Systems. within 21.3 to 24.0 VDC (UL tested range: –15%, +10%). • UL Standard 1635: Digital Alarm Communicator/Transmit- Current requirements are 78 mA in standby and 126 mAt ters. while communicating. • UL Standard 864:Control Units for Fire Alarm Systems. J4 Jumper installed: Filtered,nonresettable,and power-lim- FCC Registration: OAAUSA-25431-AL-E. Ringer Equiva- ited 12 VDC (nominal) power must be supplied at TBI Ter- lence:0.5 B. minals 1(+)and 2(–).Operating voltage must be within 11.2 to 12.4 VDC (UL tested range: –15%, +10%). Current For Canadian Applications: IC Certificate Number: 2132 requirements are 78 mA in standby and 126 mAt while 9028 A. Ringer Equivalence Number(REN):0.2. communicating. Programming: A digital programming unit with a keypad, tNOTE:A maximum of 240 mA is possible with all input chan- model PRO-411,is available for programming the 411 Series. nels active, the 411 communicating, the Programmer con- Operating Power: The 411 UD circuit board operates on fil- nected,and Lamp Test active. tered 12 VDC. The configuration of Jumper J4 determines Channe&Anputs� —TB2 Terminals 1 through 6: whether 12 VDC power is to be supplied directly to the circuit Programmable Channels 1 through 3. board,or 24 VDC power is to be supplied and then internally • e rbc Iffdit down to 12 VDC. Power-limited circuitry. .• ••'••' DC.Dower. • • • Fully supervised. 0 *so : •• ••�4 Jumper R *0 : Filtered, nonresettable and power- Operation: All channels NFPA Style B (Class B). Requires ..•... • Normally Open contact to trigger. limited 24 VD"�riinal) power must be supplied at TBi • • Te ��d� (–).Current requirements are 100 mA Normal operating voltage: 12 VDC. Terminals 7(+) •• • .if slensiby and 170 ggA4'while communicating. Maximum line resistance:100 ohms per channel. �••;•• J4•Jumper IN 00L0 : Filtered,nonresettable and power- Alarm current:3.34 mA. ••••• ;irrj&?J'12 VD (n emi al) power must be supplied at TBi End-of-line resistor:2.2K ohms,1/2 watt(P/N 27070). •�.••• terminals 7(+)N 1(–).Current requirements are 100 mA in utandby anctf7p rll&•while communicating. Short circuit current:3.8 mA per channelhnput. • *NOTE. ChannelsAnputs do NOT support two-wire smoke ••••, Channels ive the 411 Ul�•cpmrdunicating, tis hePRO-411Rible With aclonnected, detectors. •••• an(,f"mp Test alive.•• Agency Listings and Approvals cliannells/Inputs:"" Programmable Channels 1 through 4. These listings and approvals apply to the modules specified in • this docusment. In some cases, certain modules or applica- • Power-limited circuitry tions may not be listed by certain approval agencies, or listing • Fully supervised. may be in process.Consult factory for latest listing status. • Operation: All channels NFPA Style B(Class B). Requires • UL Listed:S2424. Normally Open contact to trigger. • ULC Listed:S2424. • Normal operating voltage:12 VDC. • MEA Listed: 328-94-E Vol. III (411UD); 328-94-E Vol. IV • Alarm current:3.34 mA. (411). • End-cf-line resistor:2.2K ohms. • CSFM:7300-0075:0174. • Short-circuit current:3.8 mA per channeVinput. • FDNY:COA#6085. "NOTE: Channels/inputs do NOT support two-wire smoke detectors. Product Line Information Form-C Relay: 411: Three-channel, dual-line, slave Digital Alarm Communi- s Contact rating:2.0 amps 0 30 VDC(resistive). cator Transmitter. Includes housing, operating and program- ming instructions. Requires PRO411 hand-held DACT programmer for local programming. Page 2 of 4—DN-6619:A2.4/13/2012 41 IUD:Same as above with four input channels, Form-C pro- PK-411UD:411UD programming software;ships on PK-CD. grammable relay,silence switch and remote upload/download PK-CD:Remote upload/download,Windows@-compatible pro- capability Requires PRO-411 hand-held DACT programmer gramming software Idt(for use with 411 UD only). for local programming or PK-411UD Windows-based program- ming software for remote programming and real-time diagnos- MCBL-7:DACT phone cord,seven feet long(two required). tics. NOTE:For information about 411 UDAC,see DN-6746. PRO-411: Hand-held programmer for local programming of 411 Series DACTs. Compatible UL-Listed Receivers Ademco Silent In Osborn Radlovonics Sescoa SurGuard Format# FBI Hoffman 685 Knight CS4000 600016500 3000R MLR-2 (addresses 16842) (1) 9000 (3) CP220FB Models (5) (7) (9) 0 4+1 Ademco Express ✓ ✓ 1 4+2 Ademco Express ✓ Of ✓(8) ✓ ✓ 2 3+1/Standard/1800/2300 ✓ ✓(2) ✓ ✓(4) ✓ .1(5,6) ✓ ✓ 3 3+1/Expanded/1800/2300 ✓ ✓(2) ✓ ✓(4) ✓ ✓ ✓ 4 3+1/Standard/1900/1400 ✓ ✓(2) ✓(4) ✓ ✓ ✓ 5 3+1/Expanded/1900/1400 ✓ ✓(2) ✓(4) ✓ ✓ ✓ 6 4+1/Standard/1800/2300 ✓ ✓(2) ✓ ✓(4) ✓ ✓(5) ✓ 7 4+1/Expanded/1800/2300 ✓ ✓(2) ✓(4) ✓ ✓ ✓ 8 4+1/Standard/1900/1400 ✓ ✓(2) ✓(4) ✓ ✓ ✓ 9 4+1/Expanded/1900/1400 ✓ ✓(2) ✓(4) ✓ ✓ ✓ A 4+2/Standard/1800/2300 ✓ ✓(2) ✓ ✓(4) ✓ ✓(5) ✓ ✓ B 4+2/Expanded/1800/2300 ✓ ✓(2) ✓(4) ✓ ✓ ✓ C 4+2/Standard/1900/1400 ✓ ✓(2) 44) ✓ ✓ ✓ D 4+2/Expanded/1900/1400 Of ✓(2) ✓(4) ✓ ✓ • p••• E Ademco Contact ID ✓ ✓ ✓ • • • • ••••• KEY: • (1)With 685-8 Line Card with Rev 4.4d software. ••*:*o ••• •••i• (2)With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. 066006 • (3)Rev.4.0 software. 00000 9090 •••i (4)FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. •60*•• • • • (5)Model 6500 with Rev 600 software. 0000 •••• (6)Model 6000 with Rev 204 software. 000000 ••• • • M With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. •••••• • i •••• (8)Model 2 only. •• 000:9 (9)Version 1.62 software. ••:•: • • •••••• •••••• •• • • ••• •••••• DN-6619:A2.4/13/2012—Page 3 of 4 M ' •ii• • • i •ilii• *see We i • 00.00• ' • il•l0• 0000 • • 900000 • • iil•f 0000 i•ii • 00:00 • :00:0, • •0• • 900.9• • • 0 • • 00.00• ••••0• • • •0000• •0• • l •i 0 00 NOTIFIERO is a registered trademark of Honeywell Intemational Inc. Windows®is a registered trademark of Microsoft Corporation @2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. a I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MEMMMONAMOMIN All specifications are subject to change without notice. d QUALITY SYSTEMS Made in the U.S.A For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-661 g:A2.4/132012 4