Loading...
EL-06-1843 T Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL a � � at3 Phone: (305)795-2204 Fax: (305)756-8972L J } •v: :::M P MUFF Inspection Date: 09/26/2006 Permit Type: Electrical - Residential Inspector: Devaney, Michael tLow Inspection Type: Final Owner: IRAHETA, MARIO AND TIFFANY Work Classification: Generator Job Address: 501 94 Street NE Miami Shores Village, FL Phone Number (305)754-3003 Parcel Number 1132060140850 Project: <NONE> Block: Lot: Contractor: ICR ASSOCIATES INC Phone: (305)885-6880 Building Department Comments Inspector Comments Passed Failed El Correction Needed Re-Inspection Fee ($75) No Additional Inspections can be scheduled until re-inspection fee is paid . Monday, September 25, 2006 Page 1 of 2 Inspection Worksheet ttt �t� Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 ::i::::jj:'f,.;:;::•:tvii::::S:t j<:}{}:i;:ii}:k<:;'+.'•.'••+•::...:........:...:..•y...{i:..:;••:::<::ii::::ii::i::i::i::i::i::i::i::i::i::i::i::i::i::i::i::i::::i::i::i::i::ii::i::i::;:$:•:::•:::•:::::•:•:•};S•;::} :::}::::::•:::•:::4::::::ii::::ti: :::•:: :•:::•:::•:�:•::i::i::iij:�::i::i::i::i::i::i::i::i::i::i:....:.:i::i:......::...'....:....::.:....,,.;.,,;..,.:::.. Inspection Date: 09/26/2006 Permit Type: Electrical - Residential Inspector: Devaney, Michael Inspection Type: Final Owner: IRAHETA, MARIO AND TIFFANY Work Classification: Generator Job Address: 501 94 Street NE Miami Shores Village, FL Phone Number (305)754-3003 Parcel Number 1132060140850 Project: <NONE> Block: Lot: Contractor: ICR ASSOCIATES INC Phone: (305)885-6880 Building Department Comments Inspector Comments Passed Failed Correction Needed Re-Inspection Fee ($75) No Additional Inspections can be scheduled until re-inspection fee is paid . Monday, September 25, 2006 Page 2 of 2 f &� , Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL �.,�� ;,• Phone: (305)795-2204 Fax: (305)756972 ?L&'P r:';: :.. : . ':::i::i::i::::i::::i::::i:::t::•iii ::$S:•:•iif,.:'f,.::::::$::::5::::i1'f,.:::f::$::{::::::i::j::iY:::L:Y::::i::::i::::i::::::::i::::i::::::i::::i::::is:::i::::i::::i::::i::::i::::i::'::.�:::nv ..xiv. i :.:. .iii .. :... .: :. .. .:�:::::::::::::::::.::::::..:::::::::.:::::u::::::::::::;:::::::::::::::::::::.�:::::::::::::::::::::::::::::::::... .. ... .. .:.:::... ...M. .i., ....Y::::, •' ,:;:j;: (n �t�� : �Enbbplc.::�• .��.• `.::: ..� .�. :::::::::::::::::::::::::::..::::::::::.:::::::::::::::::::.::::..:::::::::::::..::::::..::...:.:::::.::..:.......... . Inspection Date: 09/26/2006 Permit Type: Electrical - Residential Inspector: Devaney, Michael SW 27 20 Inspection Type: Rough Owner: IRAHETA, MARIO AND TIFFANY Work Classification: Generator Job Address: 501 94 Street NE Miami Shores Village, FL Phone Number (305)754-3003 Parcel Number 1132060140850 Project: <NONE> Block: Lot: Contractor: ICR ASSOCIATES INC Phone: (305)885-6880 Building Department Comments Inspector Comments Passed Failed El Correction Needed Re-Inspection Fee ($75) No Additional Inspections can be scheduled until re-inspection fee is paid . Monday, September 25, 2006 Page 2 of 2 ell toeis Al a 16 CC Al s f Cj n��p a70 t� 5? A-wf-14,jqA1 w- PAZ/,q H.: 6 "I. 10 1 �T AT 4:Rc f6 -5 L OENrET J.SERRALTA J.SERRALD; A.Y COMMISSION*DD513711 to_NTEt EXPIRES: May 17 2010 7 MY COMMISSION#D Fla EXPIRES: May 17.201b (407) 153 Fladda Notaly: E, Service.culn A0 jllv7 3 34-p` P'4.h, Z J I r 14 1 rG 1-4 -z Qr, LT__I Al,q 7'j/?A (,A, v 44eb—PQz-v�lu"gi 7- AOR MORTGAGE TRA SACTIONS- LANDTECH HEREBY AUTHORIZES CERTIFIED TITLE AGENTS SHOWN HEREON T:) Af376JNY L_;:Nt%t4.k6C ZE:71FCA710N(S) E LOW: Al T1ff_,q �+qA Sol v 6- 9 zl7- 0 00 00*000 A PA a--P 6-ri EZ 3 3 000000 0 0 0 • 0 0 0 L PER EGA L:)ESCRIPT,01, I THIS SURVEY IS BASED UPCN RECZP^;N10R:t-%h!1, 0 00 tv. i,4EASJREDAsPROV;DEDBYCLIENT NOSPE CIFICSEWIIII�o 0 N 114K FENCE OHC OVER HEAD CABLE "AS BEEN MADE 6" vv, FENCE ORB OFFICIAL RECORDS BC_ PER PLAT C R UND:mPROVEmENTS 1AVE NO'BEEN_3-A7'_[� ARC LENGTI' 0!1 1 ipeeq*�— PROPERTY LINE FIC S,,OWN 0 0 CEN7RAL A.,4c; k PC -Olt,',OF CURVATU ELIE NS ARE BASE „PON NA-IONAL AEC:)E'j(20vERTlCAL CEN7ER UNE 0 CA:C-;LA- D Cm FIELD mEA�ILRE PCC POINT OF COMPOU CUR D IN.G.V D 1979t UNLESS O_�"RWISE s�-c 696* _w E v D R_ YAF, I�N E • 7 CALCULA'EC !CIM RECORD DATA PK PARKER KALON NAI CEN *5 ARE 7,�,CEN-ERLIN 07.E C.4 CABLE'V"ISE; POB POIN'OF BEGINNIN •90641 T iN 5 CASES GRAPi­,C REPRESEN_AT<)N_p�!� IE 419-4 • 0 CE_t4,RAL ANG : OEL-A) POC POjrqT Ol COMME.14C _, _R . T Ex '0 MORE ILLJ57kATz POINT.0;REVERSE VA.0 "0 IPS -3'*V' -ALL HAVE PREC—DE N f"E 0 v IRAINAGE mEN PRC S-:)I.*,AENS,ONS$H ALL -ANGE RE PT POINT OF IONS EDGE OF ViA­ R,1w RIGHT-OF-WAY SBP BEL_ .10'WN ARE FIELD MEASURED A-IL CORR'SPON- F FLO(: SOUTH RIS L 'C p-_;, R p1FOR-.ArON UNLESS SPECIFICALLY ;-::�,IND[PON; LIE UTILITY EASEm&I C • FOUND,p wA'ER MEER SO ARE-DEN',F E�, V'7H A�2AP 1kARrED ;iq .0"; Wm I, ,SNE� # FOJINC NAIL jP - UTILITY POI E 3 Miami Shores Villa CK�� Building Departme 10050 N.E.2nd Avenue,Miami Shores,Florida Tel:(305)795.2204 Fax:(305)756.897 BUILDINGermi o. D " PERMIT APPLICATION J 10 200 Master Permit No. %- 10M FBC 2001 BY:_ Ca�� . Permit Type(circle): Building Electrical Plumbing Mechanical Roofing Owner's Name(Fee Simple Titleholder)/pfd/1/0 '�!'i 196 7r fi OL W. r)J'Fgftone#_7 9 6-' d-5/ - 7 (� Owner's Address _'o ly e �y Cityl4 i4"! S N ORCS State F/- Zip 3 Tenant'Lessee Name Phone# Job Address(where the work is being done) 5-0/ Al 4 . 7 s T2 �' �' / City Miami Shores Villa a County Miami-Dade Zip Is Building Historically Designated YES NO�_ Contractor's Company Name p /4,5-570 G 1 A rC� Phone# SWI— ® - 101Y 5 Contractor's Address 0-70 e C f /�f''C C /" e-Z c City W- P4 byi 13 c-;� • State - Zip 3 --� 41 Qualifier R�ftiR `1' H . State Certificate or Registration No.4E C 00 0 Certificate of Competency No. Architect/Engineer's Name(if applicable) Phone# $Value of Work For this Permitter-Z/9 5,- Square Footage Of Work: 6-11 Type of WQik: ❑Addition jgAlteration ❑New ❑ Repair/Replace ❑Demolition Describe Work: -4A." Tfa".,q 7-10 A 010 S 7-A /,o 1 y 6E'.NE'RA F& Submittal Fee$ Permit Fee$ CCF$ CO/CC. Notary$,--gr _ Training/Education Fee$ Technology Fee$ ^C,3 Scanning!$ q 100 Radon$ Zoning Bond$ Code Enforcement$ Structural Plan Review.$ Total Fee Now Due$ (Continued on opposite side) ♦ T Bonding ComPa'hy's'Name(i4pplicable)', Bonding ComAy's Add ess y ' 6' City ;_, State Zip Mort 6g.+6dgr' e'(if,4pplk'able) ry. Mort a Lknder's-A�JdreA- ty Ci ' 9?e .� � � Stat Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO .YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature-X ✓ c�� Signature --4 , caner or Agent Contractor The foregoing instrument was acknowledged before me this C., The foregoing instrument was acknowledged before me this day of20 ®*by tr6W`-f 13. (tZAI - day of k4&44 20 Q_�,by , who is personally known to me or who has produced PA- who is personally known to me or who has produced Q2f V,125 Z C As identificat' n and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sib: Sigu: EDWARD OfAZO .. c f>Flotlda Print: HQP7-�r& rr- l0 Print: .. �� NOTOFY EVMgp6,2003 gw.679 My Commission Expires: y AG MARGARITA PARDO My Commission E + `T,' X9,Noti0ndN0taryAss^' J20O9 My comm.expires Aug.03, No.DD458004 APPLICATION APPROVED BYPlans Examiner Engineer Zoning Chc 05/13/03 ;AN APPLICATION FOR BUILDING PERMIT MUST -ACCOMPATTY THIS ADDENDUM. IF A MASTER PERMIT HAS B. OBTAINED, THE OWNER'S NOTARIZED SIGNATURE NEED NOT BE PRESENT ON SUBSEQUENT' APPLICATIONS.] PLUMBING ELECTRICAL MECHANICAL ITEM UNIT FEE ITEM UNIT FEE ITEM a UNIT FEE ;ATH TLB SWITCH OUTLETS SPACE HEATERS 31DET LIGHT OUTLETS CENTRAL HEAT IFG 31"ASHER RECEPTACLES A/C (WIND) )ISPOSAL SERVICE TEM'ORARY A/C (CENTRAL) IRINKIN3-FOUNTAIN SERVICE SIZE IN ALPS DIDT YORK "ROAR DRAIN SERVICE REPAIR/AETER CHANGE REFRIGERATION GREASE TRAP APPLIANCE OUTLETS PROCESS AND PRESS PIPIIG INTERCEPTOR RANGE TCP UNDERGROUND TANKS LAVATORY OVEN ABOVE GROUND TANKS LAUNDRY TRAY WATER HEATER U.F. PRESSURE VESSELS CLOTHES WASHER MOTORS D 1 H' STEAM BOILERS SHOWER MOTCRS OVER 1- 3 EP HOT WATER BOILERS SINK, POT/3 COM'. I MOTORS OVER 3- 5 HP MECHANICAL VENTILATION SINK, RESIDENCE MOTORS OVER 5- 8 W TRANSPORTING ASSEM3LIES S1NK, SLOP MOTORS OVER 8- 10 H' ELEVATORS/ESCALATORS TEWORARY WATER CLOSET MOTORS OVER 10- 25 F FIRE 'SPRINKLER SYSTEMS URINAL MOTORS OVER 2.-100 FP COOLING TOWERS 'HATER CLOSET MOTORS OVER 100 FP VIOLATION INDIRECT WASTES A/C WIDOW REI,NSPECTJON I WATER SLPPLY TO: AIR CONDITIONERS TIE—ON I T STRIP HEATER FIRE SPRINKLER .. GENERATORS TRANSFORMERS �J(L. �, HEATER-NEW INST, GENERAT�tS'TRANSFORMERS j LIT HEATER-REPLACE GENERATORS TRANSFORMERS LAWN SPRINKLER-WELL SPECIAL PURPOSE SWIWING POOL OUTLETS RCIAL WATER.SERVICE SIGN TUBES SEWER CONNECTIONS '.SIGN TRANSFORMERS UTILITY-SEWER SIGN TIMI CLOCK .> _ UTILITY-WATER F I XTLRES SEPTIC TANK ANTENNA _ awl 11t�_'+� RELAY TELEVISION OUTLETS dot DRAINFIELD, 4' TILE/RES. VIOLATION PU6P 8 ABANDON SEPTIC TANK REINSPECTION SOAKAGE PIT CU. FT. CATCH BASIN 01 S>rtiARGE WELL DOMESTIC WELL 4REA. DRAIN 300E INLET STA AN fell I I •• ••• • • • . • fir- -- ,OLAR WATER HEATER I • • •• %.. : .6 IRF STANDPIPE I I ..• ..: •.: • 'AOL PIPIf<u I I I .AWN SPR I NKLER SYSTEh? I I I • ••. .AS RANGEe o I . .� . . . oo �tTEP, SET (GAS) I • • . . . . . . • • • • � I ! 1 AF PIPIk_ I ..I I ••• • • • • ••• • • • •• •• 000 • •• •• AMERICAN GENERATORS (DBA) ICR ASSOCIATES 7337 NW 32 AVE MIAMI FL 33147 305-885-6880 FAX 305-835-9965 104; TOLL FREE 1-866-486-6336 awn 3 EC-0001435 Tiffany Iraheta 501 NE 94 STREET MIAMI SHORES FL 33138 OPTIONAL LOAD CALCULATION SMALL APPLIANCE CIRCUITS 1500 VA GENERAL LIGHTING 2972 3 8916 VA LAUNDRY CIRCUIT 1500 VA POOL PUMP N/A POOL HEATER JACUZZIE DINNING ROOM N/A VA DISHWASHER 1200 VA REFRIGERATOR 1 1500 VA WATER HEATER 4500 VA DISPOSAL N/A VA DRYER N/A VA COOKTOP N/A VA OVEN 1 N/A VA TOTAL CONNECTED LOAD 19116 FIRST 10,000 AT 100% 10000 1 10000 9116 0.4 3646.4 13646.4 AIR CONDITIONG LOADS GENERAL; LOADS 13646.4 HEAT LOAD 1 6500 6500 VA TOTAL DEMAND LOAD 20146.4 240 83.94333 .. ... . . . . . .. TOTAL AMPS . .. . . . . ... . 0* ego .. a . . .. 5 A;!5'1 7�� `� ��`� ✓ �rV'r� RoFNTETJ.S A • l ••• D553711 • • • • Fes;May 17.7-010 • • • ! • • • • ♦ • ( X8-0183 Flwlde N Service com ••• • • 0 •••—t1 TIFFANY IRAHETA ICRASSOCIATES 501 NE 94 STREET 2706 CLIPPER CIRCLE MIAMI SHORES, FL. 33138 W. PALM BCH., FL. 33411' 786-251-0726 561-790-1045 EXSISTING 200 AMP 1"NIPPLE 1"NIPPLE 1$S� DDS33711 METER COMBO EXTERIOR WALL 3-#4 WIRES 3-#4 WIRES ? oa g : .y 1-#8 GROUND WIRE 1-#8 GROUND WIRE �� (407)3M-0153 Florid.NotaiN Savlae.am EXSISTING 200 AMP 100 AMP 100 AMP RATED RATED PANEL AUTOMATIC SUB PANEL M/LUG TRANSFER •• SWITCH ...... ..• . • • s ..... :004 : � • " ' 100 AMP BREAKER � NOT SEPARATELY DERIVED . FOR ATS ...... .. •ee. . • f�ly ..• . . .... ... . EXSISTING 2"NIPPLE 1"PVC SCH 80 BRANCH CKT 3-2/0 WIRES 1-#4 GROUND TO GENERATOR 1"PVC SCH 80 FUEL PIPE BONDING AS PER NEC 250.104(B) 3-#4 WIRES 1-#6 GROUND WIRE WATER SPICKET #6 GROUND WIRE 20 KW GENERATOR 100 AMP CB 5/8"X 10'GROUND ROD =6GROUND GROUND ROD #6 GROUND WIRE #6 GROUND WIRE WIRE CLIENT INFORMATION: CONSUMER GAS PLUMBING CORP. COMPANY INFORMATION: Name:IRAHETA TIFFENEY Folio: 501 NE 94 ST Total Gas Load:240 OOOBTUH TABLE:402.4(2) MIAMI SHORES Total Developed Length:62 4510 SW 154PL 402.4(14) Phone 1:786-251-0726 MIAMI FL 33185 402.4(20) Phone 2: 305 608-5400 A FIRE PLACE 40 000 BTUH i I 1"GALV SCH 40 ==' 18' STRAPPED TO THE WALL SOV 3/4" / I •••• `�� • • • • sees•• �� F -�-.�-♦ VANGE 550bfltnN •�•••• •..• • • X14' .• ... . . see •.••.• ————••— •..i• i i > 8' ---•-- ----:♦ 3/4 TRAP PIPEOFIOSS 4AbE •.•••. 80V 3/4" •sees• • • , • 3/4"TRAP PIPE CROSS SPACE ,� 1 .sees. ;,,�„ • sees•. s00000 ••eeee see* . ' ' s • sees. ***see ...• 'sees' ••ss•• 'sees' 1"GALV Stil40 e • sees•. INTERIOR TANK LESS WATER I • ; y , • HEATER 140 000 BTUH [:a I PPED?0'tff�WALL sees.• sees • • • sees • • • • ••s• . • 4 ...... 13 `� sees e• • i • • sees • •i,e �.I R ♦ I •• • ; • • SOV 3/4" T se \ I 1"GALV SCH 40 \ I STRAPPED TO THE WALL \ � I \ � I \ 8' I I SOV3/� `' I GENERATOR 250 000 BTUH 1"GALV SCH 40 I ' STRAPPED TO THE WALL I O NATURAL GAS METER �y 3/4"POLI PIPE UNDERGROUND S AS PAML7 e� u !�6 -Tc.s wooeras Goo - _ -q _ P A Il— ob � ck 1 Tib 1 `® /t•7` FZ.Eat MCE S t N �j �- - 34 k J- 1.5 ALUJP 9 JP 7-0 447- FOR MORTGAGE TRANSACTIONS-LANDTECH HEREBY AUTHOR=ES CERTIFIED TITLE AGENTS SHOWN HEREON TO ADD ANY LENDER CB XMCATIONS THEY CERTIFICATIONS)BELOW. .. ... . . . . . .. LEGEND: L - IS LEGAL aSCR&RJN 7•• ;• T•7ME-?ffBASW UPON RECORD INiQtMATKN�t - IMPORTANT NOTE — CRAW LINK F m . - MEASURED AS PROVIDED BY CU9+L NO SPECffiC SEARCH OF F THIS SKETCH OF SUR\ OIC- OVER HEAD CABLE THE MUC RECCIRD HAS BEEN MADE BY THIS OFFICE. MORTGAGE TRANSAC ..—� EN WOOD FENCE ORB _ 02 �S HAVE NOT BON LOCATED EXCEPT FOR THAT PURPOSE.Nt j�AA - C�.BYiR�N.�ANGLE - I IB PER FLAT •: : ASY WAI. SURVEY WRHOUT FIRSi CENTER LINE PC - PONT OF ,.}• ,,• • : :g�p�Tt�A g UPON NAZONAL GEODET C VERIILAL SIGNED NOTATION:'L CF - CALCUI ATED FROM FIELD MEASURE PCC - POINT OF i`R ATL ft . DAZIIt�+ry��t/D.N9291 UNIM 9�MN. THE REVISION BdV�c CR - CALC:TR.ATED FROM RECORD DATA PK - PARKER KALON NAR 4.FENCE TT13 ARF Tb OF FENCE. CAIS - CABLET V Rift POB - POINT OF NMG 5.IN SOME CASES.GRAPHIC TTAMOM HAVE BEEN MORS RESUUW �t A - CENTRAL ANGLE(DELTA) POC - FOINT OP COMMENCEME lT EXAGc;atAIED TO MORE CLEARLY MU STRATE DE - DRAINAGEEASEMETT PRC - POIN<OFREVM"RVATURE• • • •R&AV3NSIM-DIMENSIONS S9AUHAVE PRECEDENCE OVER REMON& EASE - BASEMENT PT - PCXWOFTANGEMM •EDGE OF WATER • • • FF W - FWD Ii00R S� - BELLRIW SO H ARS i i • i •••6 R!L OjS SHOwN ARE FIELD MEASU�AND SND • •• •• • • � t ll�tWaM Y NOS OUMZVAS FTP - FOUND IRON PIPE UE - UTILITY EASEMMENT••• • • • • • FIR - FOUL IRON ROD WM - WA7ER METER 7.CORNEA ST t&m AS-SEI'ARE IDOMFIED,VM A CAP MARKED IS FN - FOUND NAIL UP - UTILITY POLE %CH'TSED It 67". JUL 10 2006 Standby-Power Rating,-, Liquid Cooled sc Gas Engine 20 kW 60 HZ Generator Sets Model Numbers: 05210 -. � 05210T Ultra Quiet Mode o-t1 For Low Noise Exercise 62.2 dB(A) at 23 feet = — UL 2200 Listed .. - Power Matched *►.�_ ( • lNO ;z ." ZZ * - = Naturally Aspirated 2 Year Limited Warranty @11S LISTED Model 5210T is equipped with a 100 amp NEMA 3R Transfer Switch. Transfer Switch available for Model 5210 STANDARD EQUIPMENT • All input connections in one single area • watertight state of the art electrical connectors • High coolant temperature shutdown • Mainline circuit breaker • Low oil pressure shutdown • Radiator drain extension • Low coolant level automatic shutdown • Battery charge alternator • Overspeed automatic shutdown • 2 Amp static battery charger • Crank timer • Baa ge ry • Exercise timer • Batte r • Oil drain extension - and bel guards Y DA'T'E • Cool flow radiator hPis90s over • Closed coolant recovery system • UV/Ozone resistant hoses ZONING,DEPT FEATURES BI..DG DEPT pERnt. T GOMII • Innovative design and fully prototype tested :;1 lStgtU- f @e art R100 digital c¢,nRp�A } NS • UL2200 Listed wpteFti��i otr1-0aI • Solid state frequency compensated o�Jent-{area ruction voltage regulator High efficiency,low distortion Generac designed alternator • Dynamic and static battery charger Vibration isolated from mounting base • Sound attenuated acoustically designed enclosure • Matching Generac transfer switches engineered and • Ultra Quiet Mode for low noise level exercise tested to work as a system • Acoustically designed engine cooling s�st2m•• • ••*All components easily accessible for maintenance • High flow low noise factory engineered tj haust systepn •.•Electrostatically applied powder paint •• ••• •• • • • •• • • • ••• • • • • • • • • • • • • • • • • • • • • • • �UAADIAN-Inflip by Generac Power Systems,Inc. • • • • • • • • ••• • • 000 • 0 0 000 • 0 APPLICATION & ENGINEERING DATA au'aAofill' 20 kW GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS TYPEStandby 20 ..................................................Two-pole,revolving field MAKE.,.................... .................................................................... GENERAC ROTORINSULATION ....................................................................... Class F MODEL ....................................................................................... MMC 4G15 STATORINSULATION ...................................................................... Class F CYLINDERS :.................................................................................... 4 in-line VOLTAGE WAVE FORM DEVIATION .................................................... <5% DISPLACEMENT ........................................................ 1.5 Liter(91.5 cu.in.) TOTAL HARMONIC DISTORTION(line to line) .................................... <5% BORE ............................................................................... 75.5 mm(2.97 in.) TELEPHONE INTERFERENCE FACTOR(TIF) ..........................:.......... <50 STROKE ............................................................................. 82 mm(3.23 in.) ALTERNATOR ................................................. Self-ventilated and drip-proof COMPRESSION RATIO........................................................................ 9:4:1 BEARINGS(PRE-LUBED&SEALED) ....................................................... 1 INTAKE AIR ................................................................... Naturally Aspirated COUPLING .................................................................... Direct,Flexible Disc NUMBER OF MAIN BEARINGS ................................................................ 5 LOAD CAPACITY(STANDBY) .............................................................20 kW CONNECTING RODS .................................................... 4-Drop forged steel NOTE. Emergency loading in compliance with NFPA 99, NFPA 110, CYLINDER HEAD ........................................................................... PISTONS ......................................................................... 4-Aluminum Alloy paragraph 5-13.2.6. Generator rating and performance In accordance CRANKSHAFT ................................................................ Drop Forged Steel with/908528.5,BS5514,SAE J1349,1S03046,and DIN6271 standards. VALVE TRAIN LIFTER TYPE ...........................Overhead Cam Rocker Arm/Hydraulic Lifter VOLTAGE REGULATOR INTAKE VALVE MATERIAL ......................... High Temperature Alloy Forged EXHAUST VALVE MATERIAL ..................... High Temperature Alloy Forged TYPE................................................................................................................Electronic VALVE SEATS ....................................................................Precision Ground SENSING....................................................................................................Single Phase REGULATION.........................................................................................................±1% FEATURES................................................................................................V/F Adjustable ENGINE GOVERNOR Adjustable Voltage and Gain O ELECTRONIC.............................................................................. Standard LED Indicators FREQUENCY REGULATION,NO-LOAD TO FULL LOAD ....Isochronous STEADY STATE REGULATION .................................................. ±0.25% GENERATOR FEATURES LUBRICATION SYSTEM TYPE OF OIL PUMP ............................................................................ Gear O Revolving field heavy duty generator OIL FILTER ......................................................... Full flow,spin-on cartridge O Directly connected to the engine O Operating temperature rise 120'C above a 40°C ambient CRANKCASE CAPACITY .................................................. 3.8 Liters(4 qts.) O Insulation is Class H rated at 150°C rise O All models are fully prototyped tested COOLING SYSTEM TYPE OF SYSTEM ........................................ Pressurized,closed recovery WATERPUMP ..............................................................................Belt driven CONTROL PANEL FEATURES TYPE OF FAN ................................................................................... Pusher NUMBER OF FAN BLADES ....................................................................... 6 O SEVEN LED INDICATOR LIGHTS 0 ADDITIONAL FUNCTIONS DIAMETER OF FAN ......................................................... 380 mm(15.0 in.) •System ready •Utility sensing FUEL SYSTEM • Low fuel pressure •Delay on utility failure for engine start • Low battery voltage •Engine warm-up before transfer FUEL • Low oil pressure •Delay to retransfer to utility O Natural Gas or L.P.Vapor .......................................................... Standard • High coolant temp/low coolant temp •Engine cooldown timer CARBURETOR ............................................................................ Down draft •Overspeed •Exerciser not set SECONDARY FUEL REGULATOR. Nat. Gas or L.P. Vapor Systems •Overcrank AUTOMATIC FUEL LOCKOFF SOLENOID ................................... Standard OPERATING FUEL PRESSURE VAPOR SYSTEMS..Nat.Gas 5 to 14"H20 0 INTERNAL FUNCTIONS LP Vapor 5 to 14"H2O • 3 position switch(auto,off and manual) • Comrmunicates with rt for any transfer Generac RTS transfer switch :•• ••; '�; • AIEROELECTRICAL SYSTEM • •• . • • � 13�ATiER CHARGE ALTERNATOR ................................... 30 Amps at 12 V • Built-in 7 day exerciser . , • • p • Selectable engine speed at exercise •• •.• •• STA�TEF�hflOTOR.................................................................................. 12 V • Governor controller is built into the master control board RECbN}NCENDED BATTERY..........12 V,525 CCA @ 0°F/75 A.H.,Group 26 •Temperature range-40,C to 70°C GROUND POLARITY..................................................................... Negative . . • . • • • . • • . • . • • • . . . . • • • • • •• • • • Rating definitions-Standby:Applicable for supplying emergency power for th?duration of the util4;ower out; .Tto ovtrload capability is available for this rating. (AII ratings in accordance with BS5514,IS03046 and DIN6271). Maximum wattage and current are subject to and limited by such factors as fuel Btu content,ambient temperature,altitude,engine power and condition,etc. ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Ellieby Geimrac Dower Systems,Inc STANDBY 20kW OPERATING DATA STANDBY 20 kW Rated GENERATOR OUTPUT VOLTAGEIKW-60Hz NGILP AMP CB Size 120/240V,1-phase,1.0 pf 20 83.3 100 MOTORSTARTING Maximum at 35% instantaneous voltage dip 34 with standard alternator;60 Hz FUEL— Natural Gas and LP Vapor Only Exercise 25% 50% 75% 100% Fuel consumption — 60 Hz Cycle Load Load Load Load N.G.ft'/hr. 52 198 276 336 390 LP ff. /hr.(galJhr-for reference only) 21(.58) 79(2.17) 110(3.0) 134(3.68) 155(4.26) COOLING Coolant capacity System lit.(US gal.) 7.5(2.0) Engine lit.(US gal.) 0.9(0.25) Radiator lit.(US gal.) 6.6(l.75) Coolant flow/min. 60 Hz lit.(US gal.) 40.0(10.6) Heat rejection to coolant 60 Hz BTU/hr. 110,000 Cooling air flow 60 Hz m'/min.(cfm) 43(1528) COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz m'/min.(cfm) 2.0(70) EXHAUST Exhaust flow at rated output 60 Hz m'/min. (dm) 5.0(177) Max recommended back pressure Kpa(Hg) 5.0(1.51 Exhaust temp.at rated output °C(°F) 488(910) Exhaust outlet size N.P.T.(female) 1.5" ENGINE Rated at RPM 60 Hz 3600 HP at rated KW 60 Hz 34.8 Piston speed 60 Hz m/min.(ft./min.) 590(1937) BMEP(PSI) 60 Hz 78 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature .1.65%for every 10°F above-°F 77 Altitude -3%for every 1000 ft.above-ft. 600 SOUND OUTPUT In dB(A)at 23 feet with generator operating at full load 75.7 In dB(A)at 23 feet with generator operating at exercise 62.2 TRANSFER SWITCH SPECIFICATIONS(Hao equipped) No.of Poles 2 •• •• • • • • • •• 100 Current Rating •(ampsf . • • • • • • • Voltage Rating •.(VAC).; •' •• 250 Utility Voltage Monitor Sflkedl • • • • • • • • g •Pick-up•• •• • • • •• 80% Enclosure-NEMA 3R Standard Dropout • . • .•• 60% Return to Utility • • • • • • • ; .'• 1 minute • • • ' ' • • • Exerciser 15 minutes weekly •• • • • •• • • • Standard• • • UL Listed •.• •• '•' �' • ••• Standard Dimensions (H"x W"x D") 20 x 15 x 7 Weight 35 lbs. • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Gu�o►Feo�o►N'nite by Ge Power Syste {Irx INTERCONNECTIONS STANDBY 20 kW Transfer Switch Utility In 0000000 ro-107 70 CONTROL PANEL NEUTRAL O®O TO ALTERNATOR ® ® a Gen ®® GENERATOR N1 17 NEUTRAL ^� ®®0 CONNECTIONt19423 ° ®° Load (4)-#14 GA Out WIRES TO BOXCRCUfT 183 6REAKER GENERATOR G°°° 778 ® ® ® CONNECTION BOX TO GENERATOR r CONNECTION BOX GROUND O FRAME RAIL CIRCUIT BREAKER SIZE KW VOLTS / AMPS 20 240 10 100 Ground Level STUB-UP AREA Concrete Slab See Install Dwg for Dimensions INSTALLATION LAYOUT -- 29.5 - - ----- -- 71.0 -- ----- - - 36.5 0000� a _. -tee v o � — = 36.0 . . . . . . . . . . . . . . . . . . . . UNIT WEIGHT 776 LBS. . :•: ' :•: •• ... GENERAC POWER SYSTEMS, INC. • P.O. BOX 297 WHITEWATER, WI 53190 WEBSITE: www.giuiir al-►geri;--rators.com ResElite20kW05210 8.Q5••; ; ; • • • All specifications subject to change without notice. •• •• ICR ASSOCIATES INC. 2706 CLIPPER CIRCLE WEST PALM BEACH. FL. 33411 PH: 561-523-6641 OR 305-885-6880 TIFFANY IRAHETA 501 NE 94 ST. MIAMI SHORES, FL. 33138 CONCRETE SLAB SPECIFICATION The concrete slab contains: (1)one bag of fiber for each yard (2)Measurement are 4' x 8' x 18" (3)Total sq. ft. 64 gRAACOMMISSION EXPIRES:Ma NOTAR I+07►U"153 Fla1de NOUN S .. My Commission Expires dh: . 0:. . . . . . 0 . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . ... . . . . ... . . . . . . . . . . . . •• •• . 0 . .. .. AICRASSOCIATES TIFFANY IRAHE CONCRETE SLAB & ANCHORING 2706 CLIPPER CIRCLE 501 NE 94 STREET MIAMI SHORES, FL. 33138 W. PALM BCH., FL. 33411 786-251-0726 561-790-1045 8 FEET PIRLN . Kw � .y If,Zulu Nmin"153 Rano.N.WW$WWl Mn SLAB LL BEAT THE SAME ELEVATION OF • •• `''R" 1MTHE TOP OF THE BOTTOM FLOOR OFTHE "" '• HOUSE. ...... .... . . • THE CONCRETE SLAB CONTAINS: ""' '• •• (1) ONE BAG OF FIBER FOR EACH YARD ..... .... ...... • .... (2)MEASUREMENTS ARE 4' X 8' X 6" •• (3) TOTAL SQ. FT. 64 18 • . . • ANCHORING SYSTEM: 4 - 3/8" X 51/2"ANCHORS 20 KW GENERATOR 1,020 POUNDS TIFFANY IRAHETA ICRASSOCIATES 501 NE 94 STREET 2706 CLIPPER CIRCLE MIAMI SHORES, FL. 33138 W. PALM BCH., FL. 33411. 786-251-0726 561-790-1045 WWAW c:•�Y nys�c I Notcry PUblIC-State of Florida f • 6qpUesApt6,2W6 ;. 72 a. Bonded By Nollorwl Notary Assn. 9. • 0000 .. 00,00. 0000.. 0000 . . • 0000.. 0000. 0000 0000.. 9 0000. . 0000 0.900. 0000.. 0000 • 20 BCW GENERATOR 0000.. .. • 0000.. 0000.. 0000 . . 0000 #6 GROUND WIRE TO GENERATOR FRAME 5/8" X 10' e LEGAL DESCRIPTION LOT 13 AND THE WEST 25 FEET OF 14 , BLOCK 55 , MIAMI SHORES SECTION 2 , ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE (S) 37 OF THE PUBLIC RECORDS OF DADE COUNTY, FLORIDA. PROPERTY ADDRESS 501 NE 94TH STREET MIAMI SHORES, FL 33138 INVOICE NUMBER: 34021 DATE OF FIELD WORK: 04/13/2005 CERTIFIED TO DR MARIO P IRAHETA AND DR TIFFANY IRAHETA GMD SERVICES, INC. UNITED GENERAL TITLE INSURANCE COMPANY IMPAC FUNDING CORPORATION, ITS SUCCESSORS AND/OR ASSIGNS AS THEIR INTEREST MAY APPEAR FLOOD ZONE: X -120652-0093-J FIRE STA NE L E `[IBRARTi OO ST ry Q A LU n`-- i S NE �- 99 STP tj�G iREC �i 'd' ch O� SJQ` R�X iCTR� T NE 98 ST SI�FX"' lhYf� z �9/ ' -f w �, Q S NEJSTI 96 ST ao S NE QZ 95 ¢ ST �¢� NE z S N E MIAMId ST> 6 c0��— S ., NE 9 afSINE EQ 91 v LUST sHcuEsiT < E M s.c 10� S/C a .., — SBURY�PK I ACrt 7t—G"C,-- Cf—'-0555F57 7TI: :ESSARY TO COMPLETE SAID TRANSACTION.ANY OTHER ALTERATIONS SHALL VOID THIS SURVEY.PLEASE SIGN,DATE&ENTER ADDITIONAL •• ••• • • • • • •• SURVEYOR'S CERTIFIG4T10�i Ti 0.0 '� i •• I HEREBY CERTIFY THAT THIS BOUNDARI v PREPARED FOR THE PURPOSES OF A SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS FOR SURVEYS. 1JED TO THE INFORMATION REQUIRED AS SET FORTH BY THE FLOPPA BOARD OF SUVEYORS AND MAPPERS )NSTRUCTION SHALL BE BASED UPON THIS IN CHAPTER 61 G17-6 OFfH'.*LORID k ADMiN S,4AtI':?COZ)E, : APPROVAL AND/OR UPDATES FROM PURSUANT TO SECTION��:27,�LCWIDAS fi.TUIFES • • : LANDTEC BE CONFIRMED BY AN ADDITIONAL ELEVATIONS SHOWN-IF AP.%LI •-A�RF.�AS�D'JN•Oj� • •• 'PROVAL FOR CONSTRUCTION"LISTED IN •• • • ••• • CH ASSUMES NO RESPONSIBILITY FOR BENCH MAR SURVEYING & INSPECTIONS 10 ADHERE TO THIS CLAUS. ELEVATIO V.D.1929 Providing Land Surveying&Home Inspection Services to South Florida • • • ��`' 1500 NW 62ND STREET-SUITE 511 SIGNED: • • ' ;` � SS__ :.0 .: . FORT LAUDERDALE,FLORIDA 33309 ANDREW SNYDER PROFESSICI!AL SIWIEOatZ MID1vMAPIER FLORIDA REGISTRATION No 16J9 0 • • 000 • • (954) 776-6766 FAX: (954)776-4660 (NOT VAUD WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED L a n d T e C h S u i V e y , C O m SEAL OF THE FLORIDA LICENSED SURVEYOR AND MAPPER SHOWN I � � � N N 'ZI. I ' 4-O, n j i f 1�t rE]A/_- f -� 1,2 /1.7 ESi CAtCE t N n !,5 ' -r ; 1 Fs'Jc F`0 <�� � t•I � � . � I I N 5-, 1 i FOR MORTGAGE TRANSACTIONS- LANDTECH HEREBY AUTHORIZES CERTIFIED TITLE AGENTS SHOWN HEREON TO ADD ANY LENDER CERTIFICATIONS THEY D CERTIFICATIONS) BELOW: r • LL PER LEGAL uESMrTiviC 1.THIS SURVEY IS BASED UPON RECORD INFORMATION IMPORTANT NOTE: —X —X — CHAIN LINK FENCE M MEASURED AS PROVIDED BY CLIENT. NO SPECIFIC SEARCH OF IF THIS SKETCH OF SURVE' OHC - OVER HEAD CABLE THE PUBLIC RECORD HAS BEEN MADE BY THIS OFFICE. MORTGAGE TRANSACTIC //—//— WOOD FENCE ORB - OFFICIAL RECORDS VOK A ARC LENGTH PER PLAT • • • • ••• •:x UNDERGfOUNL•IMPROVEMENTS HAVE NOT BEEN LOCATED EXCEPT FOR THAT PURPOSE.NO PA CENTRAL ANGLE PROPERTY LME• • • • • • AS SPEC'•y--I*LL:SHOWN. SURVEY WITHOUT FIRST O CENTER LINE PC POINT OF CU",,�T4E • • ELIVATFJNS ARE EASED UPON NATIONAL GEODETIC VERTICAL LANDTECH.SAID APPROX .-.F - CALCULATED FROM FIELD MEASURE PCC - POINT OF Ci)1APOUNJ)CURVATIyRI • DATO16�N-dy,.&1929)UNLESS OTHERWISE SHOWN. SIGNED NOTATION:"LAP CR - CALCULATED FROM RECORD DATA PK - PARKER KALON NAIL 4.FENCE TIES ARE TO CENTERLINE OF FENCE. THE REVISION BAR BELOY CAN - CABLE TV RISER POB - POINT OF BEGINNING ERRORS RESULTING FROM L - CENTRAL ANGLE(DELTA) POC - POINT OF COMMENCEMENT 5.IN SOME CASES.GRAPHIC REPRESENTATIONS HAVE BEEN DE - DRAINAGE EASEMENT PRC - POINT OF REVER9EEUNVATUR"s • • ••EXAGGERATED TO MORE CLEARLY ILLUSTRATE MEASURED EASE - .EASEMENT PT - POINT OF TANGENCY • • • • •P,EL4f'ONS S-DIMENSIONS SHALL HAVE PRECEDENCE OVER REVISIONS: EOW - EDGE OF WATER R/W - RIGHT-OF-WAY •• • ••• •SCPlED POTIONS. FF - FINISHED FLOOR SBR - BELL SOUTH RISER* •• •• 6.`LL! EV4 IIQNS SHOWN ARE FIELD MEASURED AND CORRESPOND FIP FOUND IRON PIPE UE UTILITY EASEMERP• • • • ••Y� �OQQ((�=INFORMATION UNLESS SPECIFICALLY NOTED OTHERWISE. FIR - FOUND RON ROD WM - WATER METER 7.CORNERS SHOWN AS ARE IDENTIFIED WITH A CAP MARKED LB FN - FOUND NAIL UP - UTILITY POLE (LICENSED BUSINESS(#I 6799. + SH:�RCS VILLAGE , I A tM BY DATE :;PpROVED 1OWN1 S,titUi;TURra CUPY✓U<r, s ---, f �MECHhN �� B..DG S06�:;;T TO CCM, Llt'N.E STATE AND COUN['i RUES ifyU Htu ;LN •• • • • • • ••• •• • ••• • • • • •• • •• • • • •• ••• •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • •• • • • • • • • ••• • • • • ••• • • • • • • • • • • •• •• • • • •• •• • • • ••• • • • ••• - Miami Shores Village `f. 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795-2204 Fax: (305)756-8972 LLoRio Permit Permit Status: APPROVED Issue Date: 7/12/2006 Expires: 01/08/2007 Permit Number: EL-7-06-1843 Owner's Name: MARIO AND TIFFANY IRAHET_A one: (305)754-3003 Permit Type: Electrical - Residential Parcel#: 1132060140850 Work Classification: Generator Block: Lot: Job Address: 501 94 Street NE Section: PB: Miami Shores Village, FL Contractor(s) Phone Primary Contractor Total Square Feet: 0 ICR ASSOCIATES INC Yes Total Valuation: $ 2,495.00 Comments: Re uired Ins ections INSTALLATION OF A 20KW STAND BY GENERATOR Final Additional Information Type of Work: Additional Info: Classification:Residential In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above-named contractor to do the work stated. Fees Due Amount Invoice Numb r Amt Due Amt Paid CCF $1.80 EL-7-06-25535 $242.03 Education Surcharge $0.60 Total: Permit Fee-Additions/Alterations $225.00 Scanning Fee $9.00 4; 1 Technology Fee $5.63 Total: $242.03 Building Department File Copy NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS,STATE AGENCIES,OR FEDERAL AGENCIES. Applicant Signature (2—C C�CT__�_