Loading...
RF-15-2929 z \ i ti Z Miami Shores Village ��r 10050 N.E.2nd Avenue NE y \ \ \ Miami Shores,FL 33138-0000 a \�\\ M NO Phone: (305)795-2204 1, icon Eve" Expiration: 05/181201 �. 41E., Project Address Parcel Number Applicant 1384 NE 104 Street 1122320320260 BEATRICE E GARCIA&JOSE K Miami Shores, FL 33138- Block: Lot: Owner Information Address Phone Cell BEATRICE E GARCIA&JOSE 1384 NE 104 Street (786)853-4783 - -- - MIAMI SHORES FL 33138-2662 1384 NE 104 Street MIAMI SHORES FL 33138-2662 Contractor(s) Phone Cell Phone Valuation: $ 8,250.00 CITY ROOFING AND CONSTRUCTION (305)248-2994 (305)218-7901 Total Scl Feet: 792 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF OF FLAT ROOF Inspection Type: Classification:Residential Tin Cap Scanning:4 Final Roof Roof in Progress Renailing Affidavit Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 CCF Invoice# RF-11-15-57824 $5.40 11/20/2015 Check#: 1960 $783.90 $0.00 DBPR Fee $3.75 DCA Fee $3.75 Bond#:2908 Education Surcharge $1.80 Permit Fee-New Roof $250.00 Scanning Fee $12.00 Technology Fee $7.20 Total: $783.90 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING, ECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFl DAVIT: I certify th all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructio a zoning. Futher e,I authorize the above-named contractor to do the work stated. November 20, 2015 AuthorizeWgnre:Own er / Applicant / Contractor / Agent Date Building rtment Copy November 20,2015 1 Miami Shores Village , IVED Building Department NOV 19 20,5 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel: (305)795.2204 Fax: (305)756.8972 $Y: INSPECTION'S PHONE NUMBER:(305)762.4949 FBC 20 BUILDING Permit No. z;;/ir—�_._�Z9 PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: « t--A E `0,q 4�7- City: Miami Shores County: Miami Dade Folio/Parcel#: Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): F:-� CA E-• 60-w-CPhone#: -15(�V b 3-S q-1 g3 Address: l'--A&4 � t � T City: *-4 kA-t-1 l State: f-� Zip: --3�5 y>8 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: G1T/ t24Wf4 .zc-, Phone#: -::3C5 Z<4b 29G<-t Address: `ZZ'I Svc t CT City: Mb4Twl State: Fl— zip: 33no Qualifier Name: 0 fs�-O A. Phone#: State Certification or Registration#: f_CL«Z 13&1 Certificate of Competency#: Contact Phone#: - <(1G -I$3(p Email Address: 6 X1L:ct" DESIGNER:Architect/Engineer: Phone#: Value of Work for this Permit:$ Square/Linear Footage of Work: 2- Type of Work: ❑Addition DAlteration ONew Aepair/Replace ODemolition Description of Work: t2£-lzt.2X-- of RA< VaC.r)F Color thru tile: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ C7l� tJG ` Notary$. Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$� �. _ S� 7u Bonding Company's Name(if applicable) Bonding Company's Address City State zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinsp ction fee will be charged. Signature Signature - Owner or Agent C tractor The foregoing' strument was acknowledged before me this� The foregoing instrtlme actino edged before me this day of 1—a 20 kc-; ,by C7C4MV-4c.6 GAAZG,tAr , day of s..� 20 � by who is personally known to me or who has produced 'FA- who is personally known to` or who has produced � -• � � oath. aside f/ �t3 , NOTARY PUBLIC- IVIS REY NOTARY PUBLIC: Y IVIS REY MY COMMISSION#FF147325 MY COMMISSION#FF147325 '+�fid` EXPIRES:August 03,2018 EXPIRES:August 03,2018 a� Si Sig Print: Print: 1 v My Commission Expires: AA-A,%,3�zovB My Commi sion Expires: APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 31122012)(Revised 07110107)(Revised 06/10/2009)(Revised 3/15/09) lProperty Search Application-Miami-Dade County 11/13/15 8:30 AM Jim Mft aft 0 F I U` F a H fitm P ROO&raf%m tgn R"i"P sy' 'Am P P2 on"A Is tam is I Summary Report Generated On: 11/13/2015 Property Information Folio: 11-2232-032-0260 Property Address: 1384 NE 104 ST Miami Shores,FL 33138-2662 Owner JOSE A IGLESIAS&W BEATRICE E 1384 NE 104 ST Mailing Address MIAMI SHORES,FL 33138-2662 i Primary Zone 1100 SGL FAMILY-2301-2500 SQ Primary Land Use 0101 RESIDENTIAL-SINGLE �I FAMILY: 1 UNIT Beds/Baths/Half 312/1 s Floors 2 - Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,747 Sq.Ft Lot Size 8,850 Sq.Ft Taxable Value Information Year Built 1956 2015 2014 2013 Assessment Information County Exemption Value 1 $50,0001 $50,0001 $50,000 Year 2015 2014 2013 Taxable Value $136,273 $134,795 $132,065 Land Value $270,112 $177,194 $119,570 School Board Building Value $191,191 $186,373 $186,499 Exemption Value $25,000 $25,000 $25,000 XF Value $984 $9961 $1,008 Taxable Value $161,273 $159,795 $157,065 Market Value $462,287 $364,563 $307,077 City Assessed Value $186,273 $184,795 $182,065 Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value $136,273 $134,795 $132,065 Benefits Information Regional Benefit Type 2015 2014 2013 Exemption Value $50,000 $50,000 $50,000 Save Our Homes Assessment $276,014 $179,768 $125,012 Taxable Value $136,273 $134,795 $132,065 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Homestead Exemption $25,000j$25,000 $25,000 Previous Sale Price OR Book-Page Qualification Description School Board,,City, Note: Not allCity,benefits are applicable to all Taxable Values(i.e.County, 05/01/1993 $181,000 15921-3279 Sales which are qualified ,Regional). 11/01/1989 $160,000 14346-3469 Sales which are qualified Short Legal Description 32 52 42 RIVER BAY PARK ADDN PB 40-72 LOT 5 BLK 4 LOT SIZE 75.000 X 118 OR 15921-3279 0593 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at httD://www.miamidade.qov/info/dsclaimecasp http://www.miamidade.gov/propertysearch/#/report/summary Page 1 of 2 Florida Building Code Sth Edition(2014) NOV1 9 Z015 . . High-velocity Humcane Zone Uniform ermtt Application F �3Y• t Section A(Gera!Intomation) M"ster Permit Rio. - ,Process No. : E Contractor's Name. C Job Address i PIN t tL c T ROOF CATE000Y 1 0 tow Slope 0 Mechanically Fastened,"dle t� �fatfat�Adttestve.�et 3t ' ❑ Asphaltic Shingles Q Metal Pansll ngles �,1ood Si #tafr�8 Cl Prescriptive BuR-RAS 1i3 ROOF"TYPE � ❑ New roof Q Repair O Maitttertance Reroofino t1 ;Ftevet ROOF SYSTEM INF RMAVON � LowScope Roof Area{SF1 Z- Steep Stoped Roof AREA{SSF J 1'drtat Section B(Roof Plans Sketch Roof Plan: litustrate all levels and sections,roof drains,souppe�s, erflow' rs and overfly slons of sections and levels,clearly icient�fy dimensions of elevated�c�reovzcnies46 tocat n . ..•: f#•i • • • 17 f• ff #��f • •.ff M ?' « F MI M n z 4 t FLORDA aulLt3INO'CODE-SULDWS,5th::LIDMON(2M AI) t ms's Neon Fond HVHZ 2010 MIAM MM "Delivering,Excellency Every My" SEMON 15 mGrH vELoerty Ht uc m, zona- Quem owNm Nou-MUON IFFOR R010MG NsW110 1524.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to}provide the owner with the required roofing„ permit,and to explain to the owner the content of this section.:The provsiwins of Chapter 15 of the Florida Building Code,Bing govern the minuimum requirements and standards of the industry for roofing system installations. Additionally,the follow items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the items has been explained. 1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zo are for the purpose of providing that the roofing systema meets the wind resistance and water"mUmiorn performance standards. Aesthetics(appearance)are not a consideration with respect to worship proviso. Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as art of the agreement between the owner and the contractor. 2.Renalling wood decks: When replacing roofing,the existing wood roof deck may have to be r Ali in accordance with the current provisions of Chapter 16(High Velocity Hurricane Zones)of the Florid Building Cade_ (The roof deck is usually concealed prior to removing the existing roof system)_ 3.Common roofs: Common roofs are those which have no visible delineation between neighboring i.e.townhouses,condominiums,etc.).in buildings with common roofs,the roof ng cont torand/or owner should notify the occupants of adjacent units of roofing work to be performed. 4.Expensed ceiliags: Exposed,open beam ceilings are where the underside of the roof eau be view from below.'The owner may wish to maintain the arehiteotival appearance;ftrihtfre,rci8furng nail • •. penetrations of the underside of the decking.may not be acceptable.The owe r provid��.opti a ...... maintaining this appearance. • lPc►uding water: The current roof system and/or deck of the building mayCatLS- ter t7g d(accumulate)in love-lying areas of the roof. Ponding can be an ilIU • ©fls ..... !• .• ♦.1. !�.•.! distress and may rewire the review of a professional structural end.Pow:736 expectancy anti pedbrinance of the new roofing system. Ponding conditions may evtclerjit p roofer system is removed. Ponding conditions should be corrected. •,•!•• 4-�';� 6.Overflow scuppers(wall outlets): 1t is required that rainwater flow off so the the rodf is W overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this ilei if overflow scuppers(wall outlets)are not provided. it may be necessary to install overflow scups in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Cry Plumbing. 7.'Ventilatlon: Most roof structures should have some ability to vent natural airflow tbrorgh the teri r of the str€u=assembly(the building itself). The existing amount of attic'ventilation not be reduced. Exception Attic spaces,designed by a Florida-licensed engineer or registered architect to eliminate the attic renting,venting shall no be required. Owmnees/Agent's Signature. ( Date, Contractofs Signature: Pest Number- Property Address: . 1 CXA ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High-Velocity Hurricane Zone Uniform Permit Application Form. ,SBCtiOn C(Low Slope Application) Surfacing: N/A Fill in specific roof assembly components and Identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment: (If a component Is not used,Identify as•"NA") Field:9„cc @ Lap,#Rows 4 9 „oc System Manufacturer: GAF Perimeter:6"cc @ Lap,#Rows 4 @&_2 00 ��a e Product Approval No.: 14-1030.02. Corner: s it cc @Lap,#Rows 4 gD 6 it ac Design Wind Pressures,From RAS 128 or Calculations: -42.8 -71.7 108.0 Number of Fasteners Per Insulation Board: Pmaxi: Pmax2: Pmax3:- Field N/A Perimeter N/A Corner N/A Max.Resign Pressure,from the specific Product 52.5 Approval system: Illustrate Components Noted and Details as Applicable: [lack: 5/8 PLYWOOD Woodblocking,Gutter,Edge Termination,Stripping,Flashing, Type, Continuous Cleat,Cant Strip,Base Flashing,Counter- Flashing,Coping,Etc. GaugelThickness: 5/8 Indicate:Mean Roof Height,Parapet Height,Height of Base Flashing,Component Material,Material Thickness,Fastener Slope: .25 Type,Fastener Spacing or Submit AnchorlBass Sheet&No.of Ply(s):1 PLY#75 BASE ROOF HEIGHT:10'FT. • EAVEDRIP:26 GAUGE 3X3 GALVANIZEEIATT.1tlED • ••••;• Anchor/Base Sheet FastenerlSonding Material: WITH 1 1/4"R/S 4"O.0 •• • :...: •. 1 1/4"RIS NAIL&1 5/8"TINCAP ...... . ...... 1 PLY CAPSHEET • •••• • • • Insulation Base Layer: N/A 1 PLY RUBEROID#20 ••• •• ••• • Base Insulation Size and Thickness: N/A 1 PLY#75 BASE d/A • 1 PLY RUBEROID#20 9"STRIP. •• • •••• •••••• OVER-METAL • Base Insulation Fastener/Bonding Material: ;•• •Para t • N/A 3'X3'EAVE DRIP • •Het hi • •••••• Top Insulation Layer: N/A .. . . ... . . N/A10, .. Top Insulation Size and Thickness: I Top insulation FastenerlSonding Material: N/A 5I$ P � Mean Roof Base Sheet(s)&No.of Ply(s):1 PLY GAF RUBEROID#20 Height Base Sheet Fastener/Bonding Material: 518 PLYWOOD ROOF DECK ' ASTM TYPE IV ASPHALT ? Ply Sheet(s)&No.of PIy(s): N/A Ply Sheet FasteneriBonding Material: N/A i Top Ply: 1 PLY MINERAL SURFACE CAPSHEET I i t Top Ply Fastener/Bonding Material; ASTM TYPE IV ASPHALT FLORIDA BUILDING CODE 6th Edition (2014)—BUILDING 15.33 MIAMI-DiADE MIAMI-DADE COUNTY + PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Buildi4g..;. Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks.•••;•• •••••• LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,tit%state and following statement: "Miami-Dade County Product Control Approved",unless otherwNtItted ••;••, herein. ...... . .. ..... .. .. •..• ...... RENEWAL of this NOA shall be considered after a renewal application has been filed and t wfe has been no change in the applicable building code negatively affecting the performance of this product. :000:. •••• • TERMINATION of this NOA will occur after the expiration date or if there has been a?WN0*or . .. ;••••; change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0611.01 and consists of pages 1 through 30. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 14-1030.02 MIAPII•DADE COUNTY Expiration Date: 11/06/18 .•••. , Approval Date: 11/05/15 Page 1 of 30 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Matrix' 102 SBS Membrane 5 gallons ASTM D3019 Fiber reinforced rubberized cold-applied Adhesive adhesive for modified bitumen roof systems. GAFGLAS®#75 39.37" ASTM D4601 Type II asphalt impregnated and coated Base Sheet (1 meter)Wide glass mat base sheet. GAFGLAS®#80 Ultima Base 39.37' ASTM D4601 Type II asphalt impregnated and coated, Sheet (1 meter)Wide fiberglass base sheet. GAFGLAS®F1exPly'T'6 39.37' ASTM D2178 Type VI asphalt impregnated glass felt (I meter)Wide with asphalt coating. GAFGLAS®Ply 4 39.37' ASTM D2178 Type IV asphalt impregnated glass felt (1 meter)Wide with asphalt coating. • GAFGLAS®Mineral Surfaced 39.37' ASTM D3909 Asphalt coated,glass fiber mat cap ste&c •• �. • Cap Sheet (1 meter)Wide surfaced with mineral gianuld. GAFGLAS®EnergyCap' 39.37' ASTM D3909 Asphalt coated,glass fibeivmt cap ANY�� ••••:. BUR Mineral Surface Cap (I meter)Wide surfaced with mineral gmitiles with • Sheet factory applied Energy(;Md . • GAFGLAS®Stratavent® 39.37" ASTM D4897 Fiberglass base sheet coatel on both'sides ..... . .. ..... Eliminator"Perforated (1 meter)Wide with asphalt.Surfaced onthe cottomside • Venting Base Sheet with mineral granules gat%44ed in • asphaltic coating with Zctdryperforations. • GAFGLAS®Stratavent® 39.37" ASTM D4897 A nailable,fiberglass base skeet coaled 5$' Eliminator"Perforated (1 meter)Wide both sides with asphalt 6ezrfaced on tie:• Nailable Venting Base Sheet bottom side with mineral granules •• • embedded in asphaltic coating. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld"Smooth (1 meter)Wide polymer-modified asphalt and smooth surfaced. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld'Granule (1 meter)Wide polymer-modified asphalt and surfaced with mineral granules. RoofMatch7 107 sq. ft. ASTM D6164 Non-woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld' 170 FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules. NOA No.: 14-1030.02 M1Ar7FpAne C0!U Expiration Date: 11/06/18 .,•• , Approval Date: 11/05/15 Page 2 of 30 Test Product Product Dimensions Specification Description Ruberoid®SBS 39.37' ASTM D6164 Non-woven polyester mat coated with Heat-Weld'Plus (1 meter)Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid®SBS 39.37' ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld"Plus FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCap' SBS 39.37' ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld'Plus FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid®SBS 39.37' ASTM D6163 Non-woven polyester mat coated with Heat-Weld 25 (1 meter)Wide polymer-modified asphalt and smooth surfaced. Ruberoid®Mop Granule 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid®Mop Smooth 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide polymer-modified asphalt and smooth surfaced. Ruberoid®Mop Plus 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter)Wide polymer-modified asphalt and surfaced • with mineral granules. • ;••••• •,•,•, Ruberoid®Mop 170FR 39.37' ASTM D6164 Non-woven polyester r l"*oa=ed with firs, ,• (I meter)Wide retardant polymer modWw&aWhalt aril"• •0 0 0:0 surfaced with mineral grenal�s. • 0000.. Ruberoid®Mop FR 39.37' ASTM D6164 Non-woven polyester rjgVW4ed wifl DIC. • . (1 meter)Wide retardant polymer-modi easphalt dnd 00 00 surfaced with mineral gora�utas. •0 00:::0 " 00 Ruberoid®Torch Smooth 39.37' ASTM D6222 Non-woven polyester +• ted with• 0 P Y ��LsS� • (1 meter)Wide APP modified asphalt end%moth , , *00000 surfaced. 0 9 .00000 Ruberoid®Torch Granule 39.37' ASTM D6222 Non-woven polyester ms1 coated with 0•••• (1 meter)Wide APP modified asphalt and •• • surfaced with mineral granules Ruberoid®EnergyCap"Torch 39.37' ASTM D6222 APP modified cap membrane with a torch Granule FR (1 meter)Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote'. Ruberoid' EnergyCap-Torch 39.37' ASTM D6222 APP modified cap membrane with a torch Granule Plus FR (1 meter)Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCot6". RoofMatcr 107 sq.ft. ASTM D6222 Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid®Torch FR 1 meter ASTM D6222 Non-woven polyester mat,coated with fire (39.37')Wide retardant asphalt modified bitumen membrane with granule surface. NOA No.: 14-1030.02 MIAM E ADE COUNTY Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 3 of 30 Test Product Product Dimensions Specification Description Ruberoid®20 1 meter ASTM D6163 SBS modified asphalt base sheet reinforce (39.37")Wide with a glass fiber mat. Ruberoid030 1 meter ASTM D6163 Non-woven fiberglass mat coated with (39.37")Wide polymer modified asphalt and surfaced with mineral granules. Ruberoid®30 FR 1 meter ASTM D6163 Non-woven fiberglass mat coated with fire (39.37")Wide retardant,polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCap-30 FR 1 meter ASTM D6163 Non-woven fiberglass mat coated with fire SBS Membrane (39.37")Wide retardant,polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid®Dual FR 39.37"(1 meter) ASTM D6162 Non-woven polyester and fiberglass mat Wide coated with file retardant,polymer- modified asphalt and surfaced with mineral granules. Topcoat®Elastomeric Roofing 1,5 or 55 gallons ASTM D6083 An acrylic,water based elastomeric Membrane membrane system designed to protect various types of roofing surfaces. Topcoat®MB Plus 5 or 55 gallons Proprietary Water based,low VOC primer used to block asphalt bleed-through. , Topcoat® 5 gallons ASTM D6083 Solvent based sprayable therinoplas$C•••• 0000.. Surface Seal SB rubber sealant designedtoprolect and restore aged roof surfaeas%yyd-to mc;ease •••••• a roofs reflectivity. ••9••• 0 • 0000.. FireOut'"Fire Barrier Coating 5,55 gallons Proprietary Low VOC,water-based TH*carrier;0 0 0;0 • 0000 coating. '***� � *� VersaShield® 42"x 100' rolls ASTM D226 Non-Asphaltic,fire resllt � iberglees� • Fire-Resistant Roof Deck based underlayment. ,• Protection . . . . 0 9 0 0 9 9 9 . 0000.. s• • • 999 • • NOA No.: 14-1030.02 MIAM14DADE COUNTY Expiration Date: 11/06/18 �_AP_PROVE Approval Date: 11/05/15 Page 4 of 30 APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard'T'Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard7 RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"RN Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'Perlite Recover Board Perlite recover board GAF EnergyGuard'Perlite Roof Insulation Perlite roof board GAF EnergyGuard'T'RA Composite Polyiso Polyisocyanurate/wood fiberboard GAF Insulation or perlite composite Structodek®High Density Fiber Board High density wood fiber Blue Ridge FiberBoard,Inc. Securock®Gypsum-Fiber Roof Board Gypsum board United States Gypsum Corp. APPROVED FASTENERS' TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec'#12 Fastener Carbon steel fastener used Various GAF :... • . ..• in steel or wood decks. • •.. • 000000 0 •. . 2. Drill-Tec""#14 Fastener Carbon steel fastener used Various .4 ' 00000 in steel,wood or concrete .... ;•••• decks. 00000 00000. 0000. 3. Drill-Tec'XHD Fastener Carbon steel extra heavy VariousQi*V . .. 00 0 ... 000 duty fastener used in steel •• 0• 0 0:0.0 •••••• decks. •0000' • 4. Drill-Tec'AccuTrac®Flat AZ-SS aluminized steel 3"x 3" ' GA'F0000.. 000000 Plate plate for use with Drill- • • foe •••+•• Teo'#12 Fastener,Drill- •0.• Tec'#14 Fastener and Drill-Tec'#15 Fastener. 5. Drill-Tec' ASAP 3S Drill-Tec`'#12 fastener Various GAF with Drill-Tec'3" Standard Steel Plate. 6. Drill-Tec'AccuTrac® Galvalume Steel plate for 3"x 3" GAF Recessed Plate use with Drill-Tec7' fasteners. 7. Drill-Tec'3"Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill-Tec'fasteners. 8. Drill-Tec'3"Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill-Tec'fasteners. NOA No.: 14-1030.02 MIAMI-DADE COUNTY Expiration Date: 11/06/18 �� : •.. Approval Date: 11/05/15 Page 5 of 30 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. 3001276 FMRC 4470 01/28/99 1B9A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/01/98 Underwriters Laboratories R1306 UL 790 07/22/13 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/08/02 01-039 TAS 114 03/01/02 Trinity I ERD G30250.02.10-2 ASTM D6222 11/11/10 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015:...:. G40620.07.12-2 ASTM D6222 ®'1.017/12 •, • G40630.01.14-1 ASTM D6163 .••••Q jf06/14;..... G40630.01.14-2A ASTM D5147 ...Q1/.07/14 G40630.01.14-2A-1-R1 ASTM D6164 ..04/10/14. :•��� G40630.01.14-213-RI ASTM D6164 *..Q0l6/15:*•*** ••••• G40630.01.14-2C ASTM D6164 ••;94/.j07/14; •••••� G40630.03.14 ASTM D5147 •• 65/06/14 G43190.03.14-1 ASTM D5147 :"034)6/14 ' G43190.03.14-2 ASTM D5147 03706/14:... • G43190.05.14-R1 ASTM D5147 :..@%0/14 . ... ;" G43190.11.13-1 ASTM D6222 11/15/13'..' G43610.01.14 ASTM D5147 01/22/14 G46160.02.15-21) ASTM D6163 02/03/15 G46160.03.15 ASTM D6163 03/11/15 G46160.09.14-2A ASTM D5147 09/09/14 G46160.09.14-3A ASTM D6164 09/09/14 G46160.09.14-3B ASTM D6164 09/09/14 G46160.09.14-3C ASTM D5147 09/09/14 G46160.12.14-3E ASTM D6164 12/29/14 G6850.08.08 ASTM D6163 08/01/08 G6850.08.08-R1 ASTM D6164 04/14/11 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 02/17/09 SC6870.08.14-R1 ASTM D3909 09/04/14 NOA No.: 14-1030.02 i IAM1-DADS COUNT Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 6 of 30 EVIDENCE SUBMITTED: (CONTINUED) Test A2ency Test Identifier Description Date PRI Construction Technologies LLC. GAF-084-02-01 ASTM D6083 07/08/05 GAF-122-02-01 TAS 139 05/07/06 GAF-245-02-01 ASTM D6083 06/10/10 GAF-276-02-OlRev ASTM E2178 01/04/11 ASTM D6083 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 Momentum Technologies,Inc. AX04C9A ASTM D6162 06/05/09 ...... . ...... .... . ..... ...... . .. ..... . . . . ...... NOA No.: 14-1030.02 MIAMI- DE COUNTY Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 7 of 30 Membrane Type: SBS/SBS Cold Applied Deck Type 1: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOut"Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection (optional) or Securock®Gypsum-Fiber Roof Board. Base sheet: GAFGLAS®#80 Ultima fees Base Sheet,GAFGLAS®Stratavent®Eliminator" Nailable Venting Base Sheet,Ruberoid®20,Ruberoid®SBS Heat-Weld'Smooth or Ruberoid®SBS Heat-Weld'25 base sheet mechanically fastened to deck as described below: Fastening GAFGLAS®Ply 4,GAFGLAS'F1exPly'6,GAFGLAS®#75 Base Sheet or any Options: of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c.in the field. (Maximum Design Pressure—45 psf.See General Limitation#7) GAFGLAS®Ply 4,GAFGLAS®FlexPly"6,GAFGLAS®475 Base Sheet or any of above base sheets attached to deck with Drill-Tec'#12 Fastener,Drill-Tec";...; #14 Fastener or Drill-Tec'XHD Fastener and Drill-Tec'3" Steel f1lav,grill- Tec"AccuTrac®Flat Plate or Drill-Tec"AccuTrac®Recessed Plat(t fnsta'iled 12':..:. .space. o.c. in 3 rows. One row is in the 2"side lap. The other rows are e ju.a0ly d. .. .. • approximately 12" o.c.in the field of the sheet. �, . 0 0 9060 0 (Maximum Design Pressure—45 psf.See General Limitation#7).. ;fees' 0 9 0 0 0 GAFGLAS®F1exPly'6 GAFGLAS®#75 Base Sheet r any of abo% aee sheets•0 0• 00000 0000 .9 .. ...9 0000.0 attached to deck with approve annular ring shank nails and tin cap�jt.q,fastener .• s acing of 9" o.c. at the 4"la staggered and in two rows 9" o.c.in0the'fitd. .0000. (Maximum Design Pressure—52.5 psf.See General Limitation#7) 0 0 0 0 . . 0009.. GAFGLAS®#80 Ultima Base Sheet,Ruberoid®20,Ruberoid®Mop Smooth, •,*:0; 0 base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4"lap staggered and in two rows 9" o.c.in the field. (Maximum Design Pressure—60 psf.See General Limitation#7) GAFGLAS®#75 Base Sheet or any of above base sheets attached to deck with Drill-Tec"#12 Fastener,Drill-Tec'#14 Fastener or Drill-Tec"XHD Fastener and Drill-Tec'3"Steel Plate,Drill-Tec""AccuTrac®Flat Plate or Drill-Tec' AccuTrac®Recessed Plate installed 12"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c.in the field of the sheet. (Maximum Design Pressure—60 psf.See General Limitation#7) Any of above base sheets attached to deck approved annular ring shank nails and 3"inverted Drill-Tec"insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure—60 psf.See General Limitation#7) NOA No.: 14-1030.02 MIAMI•DADE COUNTY Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 26 of 30 ® above base sheets attached to deck with Fastening GAFGLAS #75 Base Sheet or an of g Y Options: Drill-Tec #12 Fastener,Drill-Tec #14 Fastener or Drill-Tec XHD Fastener (Continued) and Drill-Tec'3"Steel Plate,Drill-Tec'A AccuTrac®Flat Plate or Drill-Tec AccuTrac®Recessed Plate installed 8"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c.in the field of the sheet. (Maximum Design Pressure—75 psf.See General Limitation#7) Ply Sheet: (Optional)One or more plies GAFGLAS®Ply 4,GAFGLAS®F1exPly�'6, G S®#80 Ultima Base Sheet,Ruberoid®Mop Smooth or Ruberoid®20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop 170 FR,Ruberoid® Mop Granule,RoofMatch'SBS Modified Granular,Ruberoid®Mop Plus Granule,Ruberoid®20,Ruberoid®30,Ruberoid®EnergyCap-30 FR SBS Membrane,Ruberoid 30 FR or Ruberoid®Mop FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Granule, RoofMatch" SB �ed Granular,Ruberoid Mop 170 FR,Ruberoid Mop Plus Granule Ruberoid® Ruberoid®30,Ruberoid®EnergyCap'"30 FR SBS Membrane,Ruberoid®30 FR or Ruberoid®Mop FR adhered in MatrixTM 102 SW Membrane Adhesive at an application rate of 1-2 gal./sq. 0***:* Surfacing: Optional on granular surfaced membranes; required for smooJ6�pgq►braujS'••• •...:. Chosen components must be applied according to manufactureG's'NVlication • •••• instructions. All coatings must be listed within a current NOA. .... 0 • • •••••• .... . ..... 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively iAa,bpd coal •• 00000 • of A roved ashalt at 601bs./sa. • .. .. .... ...... 2. GAFGLAS Mineral Surfaced Ca Sheet,Tri-Ply Mineral SurfacedrGap Sheet •• or GAFGLAS EnergyCap BUR Mineral Surfaced Cap Sheet ad;erea ix a full-•••% •••••• mopping of approved asphalt applied within the EVT range and at r rate 9f 20-40 ;.•..: lbs./sq. .. ... 3. Topcoat®Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat® •• • Membrane)or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. Maximum Design Pressure: See Fastening Options NOA No.: 14-1030.02 QMIAMI-DADE COUNTY Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 27 of 30 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS®Ply 4 and GAFGLAS®F1exP1yTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4"DensDeck®Roof Board or 1/2"Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8" ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 0000.. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force•(''}valueof0 - •, 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If thefaAper value, 0000• as field-tested,are below 2751bf.insulation attachment shall not be acceptable. 000000 :0 0 0 0: 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attaclAtfif is base$.0 0:. :00009 00000 on a minimum fastener resistance value in conjunction with the maximum design valuelistedwithin • 000000 . .. ..... a specific system. Should the fastener resistance be less than that required,as deterna4ieil0by the •0;0 0• 0 Building Official,a revised fastener spacing,prepared,signed and sealed by a Floridaae4Stered 00 Engineer,Architect,or Registered Roof Consultant may be submitted. Said revised Casten&spacing000000 shall utilize the withdrawal resistance value taken from Testing Application Standards TA-8 105 and 0 :*600: calculations in compliance with Roofing Application Standard RAS 117. •• . '•' 0 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these 0 0 areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) PP ) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e, field,perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-1030.02 MIAMI•DADE couNTY Expiration Date: 11/06/18 �ua..•. , Approval Date: 11/05/15 Page 30 of 30 @ AIN F�r�EICTIt�taS flIREGTi1R ' TGFU.R1306 RoofingSystems Paae•Bottom y Roofing Systems See General Information for Roofing Systems ' BUILDING MATERIALS CORP OF AMERICA,DBA GAF R1306 1361 ALPS RD WAYNE,N]07470 USA "Ruberoid@ 20"or"Ruberoid®20 Kr"or"Ruberoid®Modified Base Sheet"may be utilized as an alternate to Type G2 base sheets in•any of the following Classifications. 1/2-in.thick(minimum)gypsum board or 1/4-in.thick(minimum)Georgia-Pacific Gypsum LLC"DensDeck@ Rootboard,""DensDeck Prime@ Roofboard"or"DensDeck DuraGuard''14.Roofboard"may be used in any existing noncombustible deck Classification.When this is done,the resulting roofing system is acceptable for use over combustible(15132-in,thick minimum)roof dealt,However,the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC"DensDeck@ Roorboard,""DensDeck Prime@ Roofboard"or"DensDeck DuraGuardlTM Roofboard"are to offset a minimum of 6-in.with the butt joints in the roof deck.If polystyrene Is part of the roof system,it must be placed below the overiayment board. Multiple plies of"GAFGLAS@ Ply 4"or'Tri-Ply@ Ply 4"or"Tri-Ply@ Ply 6"may be adhered to Georgia-Pacific Gypsum LLC"DensDeck @ Roofboard,""DensDeck Prime@ Roofboard"or"DensDeck DuraGuard' Roofboard"in hot roofing asphalt. "EnergyGuard'°"Ultra"is an acceptable altemate to"EnergyGuarcln,RF"in any applicable Classification. 0000•• GAF Stratavent@ EliminatorT"Venting Base Sheet(Nailable)"may be mechanically attached or hot mopped over*oncorvbustible Qecics and •"••� recover over existing roof systems. • • • as a • • 0000•• • 00.090 • 0000•• "GAFGLAS@ Perlite Insulation"may be utilized as a cover board over"EnergyGuard-, RF"insulation in any of the 1p4w:gwystems. • s • `Unless otherwise indicated,the roof insulation is mechanically fastened,adhered with hot mopping asphalt or UL el%sjij%d'urethar:lr?s1I1i1on ••••r adhesive.Polystyrene referenced in any of the following-Classifications include"EnergyGuardn EPS Insulation". • • Unless otherwise indicated,all insulations may be adhered with any UL Classified Insutabon Adhesive per the manN%ctL' 1s installat-N • • instructions(excluding LRF Adhesive 0)in any applicable Non-Combustible Roof Deck Classifications. •••••• • • References to glass fiber insulation include"EnergyGuard Fiberglass Insulation". • 'EnergyGuard' Tapered"is an acceptable alternate to"EnergyGuard""in any applicable Classification. •• • ••••ti • • ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet("GAFGLAS@#75 Base Sheet"or"Tri-Ply@,#75 Base Sheet",or"GAFGLAS@#80 ULTIMA")is a suitable alternate for Type G1 asphalt glass fiber ply sheet("GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4",or"GAFGLAS(D Ply 6")in the Class A,B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet"GAF Stratavent@ Eliminatorm Venting Base Sheet(Perforated)"or"GAF Stratavent@ Eliminator"Venting Base Sheet(Nailable)."Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet("GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet"or"GAFGLAS@#80 ULTIMA"or "GAF Stratavent@ EliminatorTm Venting Base Sheet(Nailabie)"may be substituted for Type G1 asphalt glass fiber ply sheet("GAFGLAS@ Ply 4"or "Tri-Ply(D Ply 4"or"GAFGLAS@ Ply 6")as the nailed base ply in the following system§. Bottom ply or base sheet maybe solid mopped,spot mopped or mechanically fastened. Unless otherwise indicated,all insulations may be hot mopped or mechanically fastened. "GAFGLAS@ Flashing"or"Ruberoid@"may be used for flashing in any of the Class A,B or C systems listed below. When"periite"is referenced,this includes"GAFTEMP PERMALiTE@"or any other UL Classified perlite insulation., http://(Iatabase.ul.com/cgi-bin[XYV/template/LISEXT/IFRAIviE/showpage.ht nl?name=T... 2/26/2014 L Q.6OG Ul Jo Crushed stone or slag are suitable alternates for gravel in any of the Class A,B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A,B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A,8 or C systems does not adversely affect the rating.The use of 1h-in.minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use Of polystyrene insulation board between minimum 3/4-In.thick perlite board and deck with rosin paper(perlite/rosin paper/polystyrene/periite)is a suitable alternate for polyisocyanurate board in the following Class A,B or C systems. "EnergyGuard-RA"or"Tapered EnergyGuardTM RA"or"EnergyGuardTM Composite RA"may be substituted for any Atlas Roofing Corp. pO,yisoCyanurate.insulation in any of the following Classifications. Trumbull"Perma Mop"may be utilized with any of the following"Asphalt Felt Systems with Hot Roofing Asphalt", "GAFGLAS@#80 Premium Base Sheet"may be used in any of the following systems. "GAFGLAS@ Flex Ply 6"and'Tri-Ply®Ultra-Flexible Ply 6"are suitable alternates to"GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board"may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated,any of the"Asphalt Felt Systems with Hot Roofing Asphalt" 3-gal/100-ft2. may be surfaced with"TOPCOAT@ Fireshield MB"at 2%to "Ruberoid@ Dual Smooth"may be used as an alternate to"Ruberoid® Mop Smooth"or"Ruberoid®20"or"Ruberoid®20 HT' "Ruberoid®Mop Smooth 1.5"may be used as an alternate to"Ruberoid@ Mop Smooth" Class A,B and C Hot roofing asphalt,for use with organic and glass felts or modified bitumen membranes. • • • 0000•• "Ruberoid®Heat Weld"SBS roofing membrane may be used in lieu of"Ruberoid®MOP"SBS products in any applicable""kation'••• • """ 0000•• • • • Class 0000•• 0000 • • • • • • 0000•• 0000• 1.Deck:C-15/32Incl •••• • �- _:3 0000•• • •• 0000• 00 •• 000• 000000 nsulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or uretQ"V: 0 0• perllte/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite os phenolic,any tl Ply Sheet:—Three or more plies Type G1 or"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ ply 6"ho$mopped. . •••••• Surfacing:—Gravel. • • • 0000•• 2.Deck:C-15/32 o. • • • Incline:2 •• • Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanu rate or urethane or perlite/polyisocyanu rate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet:—Three or more plies Type GI or"GAFGLAS@ Ply 4"or"Tri-Pty@"Ply 4"or"GAFGLAS@ Ply 64, Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCap° BUR Mineral Surfaced Cap Sheet." 3.Deck:NC Incline:2 Insulation(Optional):—One or more layers perlite,wood fiber,glass fiber,polyisocyanurate,urethane,perlite/polyisocyanurate composite,periite/urethane Composite,wood fiber/polyisocyanurate composite,phenolic,2-In.maximum. Ply Sheet:—Two br more plies Type G1"GAFGLAS@ Ply 4","Tri-Ply ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCap° BUR Mineral Surfaced Cap Sheet." 4.Deck:C-15/32 Incline: 1 Slip Sheet(Optional):—Red rosin paper,nailed to deck. Insulation(Optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc."OlySond Fastening System"or any UL Classified insulation adhesive. Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or'Tri-Ply@#75 Base Sheet"(may be nailed). Ply Sheet:—One or more plies Type G1 "GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral surfaced Cap Sheet"or'Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ http://database.ul.COM/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.ht nl?name--T... 2/26/2014 . �....bv✓ vt ✓v EnergyCaplTM BUR Mineral Surfaced Cap Sheet." Surfacing(Optional):—""TOPCOAT®EnergyCote'"Elastomeric Coating"applied at a rate of 2-gal/100-ft2. 5.Deck.NC Incline:3 Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or'Tri-Ply®#75 Base Sheet". Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply®Ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet." 6.Deck:C-15/32 Incline:2 Insulation:—One or more layers periite,glass fiber,polyisocyanurate,urethane,perlite/polyisocyanurate composite,perlite/urethane composite,phenolic,1 in.minimum(offset a minimum of 6-in.from plywood deck joints). Base Sheet:-One or more plies Type G1 or Type G2 or Type G3. Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus"or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule"or"Ruberoid@ Mop Plus Granule"or"ROOFMatchTM SBS Modified Granular"or'Tri-Ply@ SBS Modified Bitumen Membrane"or"ROOFMatchTM APP Modified Granular"or"Tri-Ply®TP-4G"or"Tri-Ply®TP-4"or"Ruberoid@ Dual Smooth". Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply®Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCapTMl BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. 7.Deck:C-15/32 Incline:2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or periite/urethane composite or wood fiber/polyisocyanu rate composite or phenolic,any thickness. Base Sheet:—Two or more plies Type G2 or Type G3. Ply Sheet(Optional):—One or more plies Type GS. Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus"or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus"or"Ruberoid®Mop Granule"or"Ruberoid@ Mop Plus Granule"or"ROOFMatch" SBS Modified Granular"or"Tri-Ply®SBS Modified Bitumen Membrane"or"ROOFMatch'"APP Modified Granular"or"Tri-Ply®TP-4G"or"Tri-Ply®TP-4"or"Ruberoid®Dual Smooth". Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply®Mineral Surfaced Cap Sheet"or"GAFGLAS@ EvrgyCV, BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. •• S.Deck-NC �••• i • • •• Incline:2 • •••••• • •••••• Insulation(Optional):—Perlite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened,any thickness. • � ;•••'; Base Sheet:—One or more plies Type G2,"GAFGLAS@#75 Base Sheet"or"Tri-Ply®#75 Base Sheet". • . ...••• Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply®Ply 4"or"GAFGLAS@ Ply 6". •••• • ••••• Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet"of G;iW"4S@ EnargyGep- •• •• BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. • • • • • Surfacing:—'TOPCOAT@ Fireshield MB"applied at 21/2 to 3.0-gal./100-ft2. •• • :• 9.Deck:C-15/32 Incline: 1 • i•••i• • • • • • Insulation(Optional):—One or more layers periite or wood fiber or glass fiber or polyisocyanurate or urethane or• •• '•' periite/polyisocyanurate composite or Perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet:—Three or more plies Type G1"GAFGLAS@ Ply 4"or'Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—"GASFGLAS@ EnergyCap'"BUR Mineral Surfaced Cap Sheet". 10.Deck:NC Incline:1 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,2-1n.maximum. Ply Sheet,—Two or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—'GAS FGLAS@'EnergyCap—BUR Mineral Surfaced Cap Sheet". 11.Deck:NC Incline:2 Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet". Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—"GASFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet". 12.Deck:C-15/32 Incline: 1 Insulation:—One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polylsocyanurate composite or perlite/urethane composite or phenolic,1-in.minimum(insulation joints offset a minimum of 6-in,from plywood deck joints). Base Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6"or Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet"or Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet". http://database.ul.com/cgi-bin/XYV/template/LISEXT/lFRAME/showpage.ht nl?name--T... 2/26/2014 Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus"or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule"or"Ruberoid@ Mop Plus Granule"or"ROOFMatchT"SBS Modified Granular"or"Tri-Ply SBS Modified Bitumen Membrane"or"ROOFMatch� APP Modified Granular"or"Tri-Ply@ TP-4G"or"Tri-ply@ TP-4"or"Ruberoid@ Dual Smooth." Cap Sheet:—"GASFGLAS@ EnergyCap""BUR Mineral Surfaced Cap Sheet". 13.Deck:C715/32 Incline: 1 Insulation(Optional):—One or mope layers periite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanu rate composite or pedite/urethane composite or wood fi ber/polyisocyanu rate composite or phenolic,any thickness. Base Sheet:—Two or more plies Type G2"GAFGLAS@#75 Base Sheet","Tri-Ply@#75 Base Sheet",or Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or'Tri-Ply@ Mineral Surfaced Cap Sheet". Ply Sheet(Optional):—One or more plies Type G1. Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ ^ Plus" or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop oSm oh Plus"oor Ru beroo @ Mop Granule"or"Ruberoid@ Mop Plus Granule"or"ROOFMatch""SBS Modified Granular"or"Tri-Ply@ SBS Modified Bitumen Membrane"or"ROOFMatchlm APP Modified Granular"or"Tri-Ply@ TP-4G"or"Tri-Ply@ TP-4"or"Ruberoid Dual Smooth". Cap Sheet:—"GASFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet". 14.Deck:C=15/32 Incline:2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate perlite/polylsocyanurate composite or wood fiber/polyisocyanurate composite any thickness mechanically or adhered with hot roofing asphalt. Base Sheet.—One ply"GAFGLAS@ Stratavent-Eliminator Venting Base Sheet"or Type G2 fully adhered with hot roofing asphalt Ply Sheet:—Two or more plies Type G1 or"Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus" or"Ruberoid@ 20"or"Ruberoid@ 20 HT'fully adhered with hot roofing asphalt Membrane:—"GAFGLAS@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt 15.Deck:C-15/32 Incline: 1 Insulation(Optional):—Any thickness partite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive. Barrier Board:—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck Prime@ Roofboa4 ow:• "DensDeck DuraGuardTM Roofboard"or minimum 1/4-in.thick Untied States Gypsum Corp."SECUROCK@ RoofiBoardw gype FRX-G)or "SECUROCK@ Glass-Mat Roof Board"(Type SGMRX)mechanically fastened or adhered with OMG Inc."OlyB0%g9st ing System"ar any • UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6-in.from ivood detR jbtV.Base �•�•;� Ply Sheet:t-OnOenortwo plies ype G2 e Gi GAF".GAFGLAS@ Ply 4S#75 Base h ort'Tri-Ply 4"I o�GA75 FGLAS@ Flexlyase Sheet" h6"no rType 61 LAS@#75 ease Sheet"or"Tri-Ply#75 Base Sheet"fully adhered with hot roofing asphalt ••••`` Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt • Surfacing ^ ••••• :••••• ••••• (Optional):):—"TOPCOAT@ EnergyCote�+Elastomeric Coating" at a rate of 2-gal/100-ft2. • • •••••• • •• ••••• 16.Deck:NC ••�••• •••••� •••••• Incline:1/2 • • • •••••• Insulation(Optional):—Any thickness periite or wood fiber or glass fiber or polyisocyanurate,mechanically fastened or a j e`Vd•with • • "LRF Adhesive M"or OMG Inc."Olybond Fastening System"applied as a nominal 3/4-in.bead or"GAF 2-ParteRoofwng.Adhesive"aVIigd as ••••; a nominal 2-1/2-in.bead with a maximum on-center spacing of 12-1n.or any UL Classified insulation adhesive`fpiieb per thQ manufacturer's installation instructions. 9• Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet",mechanically fastened Ply Sheet:—One or two plies Type GI"GAFGLAS@ Ply 4"or'Tri-Ply@ 4"or"GAFGLAS@ Flex-Ply""6"or Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet",fully adhered with hot roofing asphalt. Cap Sheet.—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet",fully adhered with hot roofing asphalt Surfacing:—'TOPCOAT@ EnergyCote' Elastomeric Coating"or"TOPCOAT@ MB Plus"or"TOPCOAT@ 322 White Elastomeric Coating", applied at a rate of 2-gal/100-ft2. 17.Deck:C-15/32 Incline: 1/2 Insulation(Optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive. Barrier Board:—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck Prime@ Roofboard"or "DensDeck DuraGuard""Roofboard"or minimum 1/4-In.thick Untied States Gypsum Corp."SECUROCK@ Roof Board"(Type FRX-G)or "SECUROCK@ Glass-Mat Roof Board"(Type SGMRX)mechanically fastened or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6-in.from plywood deck joints. Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply#75 Base Sheet"mechanically fastened Ply Sheet:—One or two plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply 4"or"GAFGLAS@ Flex Ply 6"or Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply#75 Base Sheet"fully adhered with hot roofing asphalt. Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. Surfacing:—"TOPCOAT@ EnergyCote""Elastomeric Coating"or'TOPCOAT@ MB Plus"or"TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-1t2. 18.Deck:NC Incline: 1 http://database.ul.com/egi-bus/XYV/template/LISEXT/1FPAN E/showpage.htnl?name=T... 2/26/2014 I Insulation(Optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate,mechanically fastened or adhered with "LRF Adhesive M"or OMG Inc."Olybond Fastening System"applied as a nominal 3/4-in.bead or"GAF 2-Part Roofing Adhesive"applied as a nominal 2-1/2-in.bead with a maximum on-center spacing of 12-in.or any UL Classified Insulation adhesive applied per the manufacturer's installation instructions. Base Sheet,—One ply"GAFGLAS@ Stratavent@ EllminatorTM Venting Base Sheet"or Type G2,fully adhered with hot roofing asphalt Ply Sheet:—One or two plies"Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Pius"or"Ruberoldc!� 20"or"Ruberoid@ 20 HT,fully adhered with hot roofing asphalt Membrane:—One ply"GAFGLAS@ Mineral Surfaced Cap Sheet,fully adhered with hot roofing asphalt Surfacing;—"TOPCOAT@ EnergyCote� Elastomeric Coating"or"TOPCOAT@ MB Plus"or"TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-ft2. 19.Deck:C-15/32 Incline; 1 Insulation(optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive. Barrier Board:—Minimum 1/4-in.thick Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck Prime@ Roofboard"or "DensDeck DuraGuardl Roofboard"or minimum 1/4-in.thick Untied States Gypsum Corp."SECUROCK@ Roof Board"(Type FRX-G)or "SECUROCK@ Glass-Mat Roof Board"(Type SGMRX)mechanically fastened or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6-in,from plywood deck joints. Base Sheet:—One ply"GAFGLAS@ Stratavent Eliminator Venting Base Sheet"fully adhered with hot roofing asphalt Ply Sheet:—One or two plies"Ruberoid@ Mop Smooth"or"Ruberoid M " „ @ o Smooth Plus full adhere P Y d with hot roofing asphalt Membrane.—One ply GAFGLAS@ Mineral Surfaced Ca Sheet" g p Cap eet"fully adhered with hot roofing asphalt Surfacing:—"TOPCOAT@ EnergyCoteTM Elastomeric Coating"or"TOPCOAT(ID MB Plus"or"TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-ft2. J20,Deck:C-15132 Incline:.1 Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet'mechanically fastened, Insulation(Optional):—Any thickness or combination.perlite or wood fiber or glass fiber or polyfsocyanurate,mechanically fastened at hot mopped or adhered with OMG Inc."OlyBond Fastening System"or any UL Classified insulation adhesive. Base Sheet: One or more plies"Ruberoid@ 20"or"Ruberoid@ 20 HT'or"Ruberoid@ Modiffed Base Sheet",hot mopped;or mechanically attached. Cap Sheet: One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap.Sheet"or"GAFGLAS@ '. EnergyCap-BUR Mfneral Surfaced Cap Sheet." 0000•• Class �•� • ••••�• 0000•• • 1.Deck:C-15132 Incline:3-1/2 •••i•• • •••••• 0000•• • • • 0000•• 0000 • • • • Insulation(Optional)- -One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urdw&pr ;•••" •.•.• perlite/polyisocyariurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic;any thicvvs. 00;0 go Pty Sheet:—Two or more plies Type Gi"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6"mechtjlVlj�astenec: • • Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or'Tri-Ply@ Mineral Surfaced Cap Sheee100"C3rkfGLAS@ Erre?g"ap— 00000 BUR Mineral Surfaced Cap Sheet",fully adhered with hot roofing asphalt. 0 0000•• • • • • • 0000•• 2.Deck:C-15/32 Incline:3-1/2 •0 0 0 0' 0 • • • 0000•• 00 9 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or 0 • • periite/polyisocyanu rate comppsite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Base Sheet:—Two or more plies Type GI or Type G2 or Type G3. Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus"or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule"or"Ruberoid@ Mop Plus GPanule"or"ROOFMatchTM SBS Modified Granular"or'Tri-Ply@ SBS Modified Bitumen Membrane"or"ROOFMatch' APP Modified Granular"or"Tri-Ply@ TP-4G"or"Tri-Ply$TP-4"or"Ruberoid@ Dual Smooth." Cap Sheet:—"GAFGLAS@ Mineral Surfaced Cap Sheet",or"Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCapT BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. 3.Deck:C-15/32 Incline:2-1/2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polyisocyanurate composite or periite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet.—Two or more plies Type G3"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6". Cap Sheet:—"GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet". 4.Deck:C-15/32 Incline.2-1/2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Base Sheet:—Two or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Ply 6"or Type G2"GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet'or Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or'Tri-Ply@ Mineral Surfaced Cap Sheet." Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus"or "Ruberoid@ Mop Smooth"or"Ruberoid@ Mop Smooth 1.5"or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule"or"Ruberoid@ Mop Plus Granule"or"ROOFfMatchTM SBS Modified Granular"or'Tri-Ply@ SBS Modified Bitumen Membrane"or"ROOFMatchTM APP Modified http://database.ul.conVegi-bin/XYV/template/LISEXT/l FRAME/showpage.html?name=T... 2/26/2014