WS-15-1033 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-241166 Permit Number: WS-4-15-1033 Scheduled Inspection Date: November 25 2015 p � Permit Type: Windows/Shutters Inspector: Rodriguez,Jorge Inspection Type:YNe: Final Owner: MICHELLE, DANILO DI Work Classification: Door Replacement Job Address:9145 NE 4 Avenue Miami Shores, FL 33138 Phone Number Parcel Number 1132060140080 Project: <NONE> Contractor: HOME OWNER Building Department Comments REPLACE FRONT DOOR. Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-237069. CREATED AS REINSPECTION FOR INSP-233751. Front door of the house not installed per the product approval. Also need to provide engineers details and specifications for the wood buck Failed installation. PE MUST SPECIFY ON LETTER FASTENING OF 2X WITH SIZE AND Correction ❑ SPACING JAMB ON BOTH SIDE OF DOOR DO NOT MEET MIN EGDE Needed DISTANCE PRESENT TAP CONS ONJAMB DO NOT MEET MIN PENETRATION OF 1 NA Re-Inspection Fee No Additional Inspections can be scheduled until re-inspection fee is paid. November 24,2015 For Inspections please call: (305)762-4949 Page 8 of 42 Miami Shores Village 'Iding Department AUG � 2D15 N .2nd Avenue, Miami Shores, Florida 33138 e (305)795-2204 Fax:(305)756-8972 1 ION LINE PHONE NUMBER:(305)762-4949 FBC 20 G Master Permit No. PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING 21 REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS L 4� JOB ADDRESS: City: Miami Shores County: Miami Dade Zia: Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: �Q OWNER: Name(Fee Simple Titleholder): T;;�c l'� l �' C `Z Phone# Address:_ �1 - City: cv( �� State: �L- Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: GOA_ _ Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee$ 2 Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT C MENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will n 'be approved and a reinspection fee will be charged. Signature Signature OWN or AGENT CONTRACTOR The foregoing i strument was acknowledged before me this The foregoing instrument was acknowledged before me this —IW9 da of �+ ,20 by day of 20 by rl � CJS 1+ who is personally known to who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: Seal: ° Notary P"'P$4*�f FIAri* ;4 Slndia FIV geg Seal: My cormAmi56iNH FF 151750 pFµo EgP0409/51/3098 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) \ \ X 01 OR Miami Shores Village 10050 N.E.2nd Avenue NE ` Miami Shores, FL 33138-0000 au Phone: (305)795-2204 � '\ a . Expiration: 11/14/2015 Project Address Parcel Number Applicant 9145 NE 4 Avenue 1132060140080 Miami Shores, FL 33138 Block: Lot: DANILO DI MICHELLE Owner Information Address Phone Cell DANILO DI MICHELLE 9145 NE 4 Avenue MIAMI SHORES FL 33138- 9145 NE 4 Avenue MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 500.00 HOME OWNER Total Sq Feet: 0 ��] Type of Work:REPLACE FRONT DOOR. Available Inspections: No of Openings: 1 Inspection Type: Additional Info: Final Classification:Residential Review Building Scanning:3 Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $0.60 Invoice# WS-4-15-55391 DBPR Fee $2.00 04/30/2015 Credit Card $50.00 $74.60 DCA Fee $2.00 Education Surcharge $0.20 05/18/2015 Credit Card $74.60 $0.00 Permit Fee $110.00 Scanning Fee $9.00 Technology Fee $0.80 Total: $124.60 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING, MECHANICAL,WINDOWS, DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I that all th for going information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. cher ore, I au a above-named contractor to do the work stated. May 18, 2015 Authorized Sig9kyXeW. WYeF / A plicant / Contractor / Agent Date Building Departmefif Copy May 18, 2015 1 Miami Shores Village - g 7BXY Building Department010050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(30S)762-4949 FBC 20_10 BUILDING Master Permit No.wS PERMIT APPLICATION Sub Permit No. UILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 04E City: Miami Shores County: Miami Dade Zip: 33 1 *5 Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name(Fee Simple Titleholder): Av,7.'10 �•I Mi,Cgr� Phone#: To%A 0 Address: City: State: Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: iE O Phone#:74B?-3LA -5%14 o Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee$ •C0 Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ 't " (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which ccurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will no be approve and a reinspection fee will be charged. Signature Signature OWN or AGENT CONTRACTOR The foregoing in rument was acknowledged before me this The foregoing instrument was acknowledged before me this day of 20 by day of 20 by 100+41lb 1pl Ml who is personally known to who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: Seal: � r►tie Notary Public State of Florida Seal: `[• Sindia Alvarez y, < My Commission FF 156750 Fpr q Expires 09/0312018 **************** * ******* **** ** ********************************************************************* APPROVED BY , V3 Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) OR Miami Shores Village Building Department lung10050 N.E.2nd Avenue s Miami Shores Florida 3313 ,r 8 �oRmp Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: 'gyp�. lei 1i E DATE: }}WA l5 ADDRESS: q I �S N 4`C �V 1"l• tS Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida,F.S 489.103(7).And I have read and understood the following disclosure statement,which entitles me to work as my own contractor;I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor.You have applied for a permit under an exception to the law.The exemption allows you,as the owner of your property,to act as your own contractor even though you do not have a license.You must supervise the construction yourself.You may build or improve a one-family or two-family residence.You may also build or improve a commercial building at a cost of$25,000.00 or less(The new form states 75,000).The building must be for your own use and occupancy.It may not be built for sale or lease.If you sell or lease a building you have built yourself within one year after the construction is complete,the law will presume that you built for sale or lease,which is a violation of this exemption.You may not hire an unlicensed person as a contractor.It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances.Any person working on your building who is not licensed must work under your supervision and must be employed by you,which means that you must deduct F.I.C.A and with-holdings tax and provide workers'compensation for that employee,all as prescribed by law.Your construction must comply with all applicable laws,ordinances,buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have app'.ed for an owner-builder permit under an exemption from the law.The exemption specifies that I,as the owner of the property listed,may a as my own contractor with certain restrictions even though I do not have a license. Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he r e is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that,as an owner builder,I am the responsible party of record on a permit.I uncle t n that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name inste oy own name.I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permit and contracts. Initial 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding. ay also build or improve a commercial building if the costs do not exceed$75,000.The building or residence must be for my use or ocpancy. It may not be built or substantially improved for sale or lease.If a building or residence that I have built or substantially improved y elf is sold or leased within 1 year after the construction is complete,the law will presume that I built or substantially improved it for sale or I ase,which violates the exemption. Initial ; 5. 1 understand that,as the owner-builder,I must provide direct,onsite supervision of the constructi'o . Initial 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise per ons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law an by county or municipal ordinance. Initial 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner-builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner-builder,may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while rking on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner-builder ar d am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done.Any person working on my building who is not licensed must work under my direct supervision and must be employed by me,which means that I must comply with laws requiring the withholding of federal income tax and ocial security contributions under the Federal Insurance Contributions Act(FICA)and must provide workers compensation for the employ .I understand that my failure to follow these may subject to serious financial risk. Initial 9. 1 agree that,as the party legally and financially responsible for this proposed Construction activity,I w' abide by all applicable laws and requirement that govern owner-builders as well as employers.I also understand that the Construction must comply with all applicable laws,ordinances,building codes, and zoning regulation . Initial 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Int rnal Rev vice,the United States Small Business Administration,and the Florida Department of Revenues.I also understand that I may co t the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.mvfloridalicense.com/dbor/pro/cilb/index.html Initial 11. 1 am aware of,and consent to;an owner-builder building permit applied for in my name and underst nds that I a he party legally and financially responsible for the proposed construction activity at the following address: Initial 12. 1 agree to notify Miami Shores Village immediately of any additions,deletions,or changes to any of the i rmation that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public.If you contract with a person who does not have a license,the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court.It is also important for you to understand that,if an unlicensed contractor or employee of an individual or firm is injured while working on your property,you may be held liable for damages.If you obtain an owner-builder permit and wish to hire a licensed contractor,you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued,this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit.A copy of the property owner's driver license,the notarized signature of the property owner,or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this SO day of A, I ' 120 1S By ),1Akacn, 1�; 1_�' �6 who was personally known to me or who has Produc d there License or as identification. .Par AUK. r;,v y?;oj: =ae.)f F'orida OWNER OTARY Siiipi,< !v �uu Mu Gnmmiss�on FF 156750 ort+d` E>,• '50910312018 z i v APR 3 Dor E 03 3 t Fl4' 2 IG IV— ",!Mi a, L FR, P4 CIULJ --1 t4 � 0000 V . • •..• 0000.• •• • •..• • 0000• 0000 ••00.• • 0000 •• •• 9 0..• •ii0• 0000 0000• • 0 • • • •• 0000 f.0..• • 00:6: • •0•••• • • • • • • 0 IIS - "•�` •' �` MIAMI-DADECOUNTY PRODUCT CONTROL WX TION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES 11805 SW 26 SUvet,Ra mn 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 31115-2474 T(786)315-2590 F(-M)315.2599 NOTICE OF ACCEPTANCE NOA MMin amidede:godmildlug F.P.G.Wholesale,Inc. 7190 Coral Way Miami,FL 33155 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction matariids. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictiaa (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the ight to have this product or material tested for quality assurance purposes. If this product or material fails to perkmm in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immdiately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the fight to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this prduct or material.fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the High Velocity Huna me Zone of the Florida Building utile. DESCRIPTION: Series"Condoor Impact"81011 Outswing Opaque Wood French Door w/wo Sidelites--L.W. APPROVAL DOCUMENT.-Drawing No.W10-11.,titled"Series Out-Swing Wood Patio Door(L.M.I.)",sheets 1 through 8 of 8,dated 03/11/09 with revision"B"dated 05/03/12,prepared by Al—Farooq Corporation,signed and sealed by Javad Ahmad,P.E.,bearing the Miami—Dade County Product Control Revision stamp with the Ndice of Acceptance number and the expiration date by the Miami—Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and b following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein... RENEWAL of this NOA shall be considered after a renewal application has been file*and'there h.&* en m •'••;• change in the applicable building code negatively affecting the performance of this product. • :000 TERMINATION of this NOA will occur after the expiration date or if there has been-a WWsion or change in tii�e 0 0.0 materials,use,and/or manufacture of the product or process.Misuse of this NOA as arkendeVemer}t otagy product,for sales,advertising or any other purposes shall automatically terminate this NOW Failure to cben# ••;•• with any section of this NOA shall be cause for termination and removal of NOA. 66:00: ....•. ••••• .. 0- 0000 0000.. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade Countj,.1110 ida, and follovd by.• the expiration date may be displayed in advertising literature. If any portion of the N A is c ispla.. then itsll+ail:• be done in its entirety. . . 0000.. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its-4i#W1 utz • and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#10-0503.03 and consists of this page 1,evidence submitted pages E-1 and E-2 as vn11 as approval document mentioned above. The submitted documentation was reviewed byylr_/v elmy A.Makar,P.E.,M.S. W./1(1.- NOA No.12-0514.22 C Expiration Date: 08/Mld5 C7�v � .a/ Approval Date: 07/o5%]12 pop B F.P.G.Wholesale,Inc. NOTICE OF-ACCEPTANCE: EVIDENCE SUBMITTED" 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL OVAL#10-0583.03 A. DRAWINGS 1. Manufacturer's die drawings�' and d s ections. 2. Drawing No WIO41, titled Series Out- 'wing Wood Patio Door(L.M.I.) , sheets 1 through 8 of 8, dated 03111109 with revision "A"dated 06130110,prepared by Al= Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. Test reports on: I)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 24113.2.1, TAS 202-94 along with marked-up drawings and installation diagram of OS French door, prepared by Hurricane Engineering and Testing, Inc., Test Reports No. 's HETI--09-2501, HETI-08-2119A, HETI-08-2119B and HETI-08-21 72, dated November 23, 2009 revised dated July 13, 2010, all signed and sealed by Candido F. Font, P E. C. CALCULATIONS 1. Anchor calculations and structural analysis, complying with FBC-2007,prepared by Al-Farooq Corporation, dated 12114109, signed and sealed by Javad Ahma4 P. E. Complies with ASTM E1300-04. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office(BCCO). E. MATERIAL CERTIFICATIONS •••' . . 9999 9999.. 1. None. • 9999.. 9999 9999.. F. STATEMENTS •••'•• • 9999.. 1. Statement letter of no financial interest, conformance and cramp 4rnce wilt-I&FBe.- • 9999 2007, dated December 10, 2009, signed and sealed by JavadAw4 P. &.. 90:000 2. Laboratory compliance letter for Test Reports No. 's HETI-09-02561,HAVA •8-211*4, :• HETI-08-2119B and HETI-08-2172, issued by Hurricane:�3ig'I keering dnd Testin��� Inc., dated November 23, 2009 revised dated July 15, 2010, �11 s;gned oW staled Sy Candido F. Font P. E. •••••• , .. 9999 Helm A.MaarP.E. MS. Y , , Product Control Unit Supervisor NOA No.12-0514.12 Expiration Date: 08/25/20]5 Approval DAN-P 07/05/2412 E-1 F.P.G.Wholesale,Inc. MTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W10--11, titled "Series Out-Swing Wood Patio Door(L.M,1)", sheets I through 8 of 8, dated 03111109 with revision "B"dated 05103112,prepared by AI— Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor calculations complying with FBC-2010,prepared by AZ—Farooq Corporation, dated 05108112, signed and sealed by Javad Ahmad, P. E. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of no financial interest, conformance and compliance with the FBC 2010, dated Apri12S, 2012, signed and sealed by Javad Ahmad, P. E. • • •••• •••••• • •• •• •••• •••••• • • • • • • 00 0 • • Helmy A.Makar,P.E.,MS. Product Control Unit Supervisor NOA No. 12-0514.22 Expiration Date: 08/25/2015 Approval Date: 07/05/2012 E-1 SURFACE SOLT LENGTHS 96" LEAF HT. = 42" LONGCL r-84' LEAF HT = 30" LONG I 80" LEAF HT - 26" LONGT 6" MAY E —FttAL. �iLL — s HEAD/SILL cONCEaIEU. HEAD/SILL r a _rurRX FLUSH BOLTS CORNERS 24' MAX, 7.2 �/8" HEAD/SILL h. � 9j Z W 10 Im cm to 0 10 D.L.O.. d CORNERS N' .Q I I , D,L, OPG. �" LU rs i S! 0 O O \' .` G co ix t- •\ '. - R `i / •4. i i.,"i 'i �, \t t `` ',� 9 Z00 1841 10 S 4 _t``S` ,•,. \- ` '..,� 41 -A� ti `, �, , 6i lei \ ````' •I `, 1 ','% QIP! tL 1ti t \�' \ j `1 .ti ® •!� 4;-•�` / \': `;`•`';•,` '1`\ /^� ` ` \ ® \ `• ' 0 \ i nQ LO n to ACTIVE `' —L ACTIVE 0 `.f !/ INACTIVE O -1 `= N i .' C.9 _•�•0 rq •••••• C •• z j N •• FLUS CONCBOLLTS Q ��••i• C9 �- a ••••i• O•— m 3/4 MAX. 37 ' 36" MAX. 37 3/4" MAX. 36' " MAX. 37 3J4" MAX. �! L*•••• d �.:' LEAF WIDTH LEAF WIDTH LEAF WIDTH LEAF WIDTH ••••. • • . ••••• 74 1/2" MAX. 150 1/2" MAX. SIDELITE WIDTH FRAME WIDTH FRAME WIDTH ":' • T_Y_PICAL E:L0jATI ON,$ PRODUCT REVISED '••'• a i••••i OUT—SWING WOOD PATIO DOOR as complying with the Florida BuiWiing Code o �' o Acceptance No 2 a .ZZ APPROVAL APPLIES TO SINGLE (X) AND DOUBLE (XX) LEAF DOORS 33�clairation Date Oar,,' - WITH OR WITHOUT SIDELITES. fn w j SIDE LITES CAN BE ON ONE SIDE OR BOTH SIDES OF DOOR. i3y U ucttntroi SEE SHEET 2 FOR DESIGN LOAD CAPACITY. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE o cs o REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY SOLID WOOD INSERTS to HURRICANE ZONE (HVHL). LARGE MISSILE IMPACT WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. g o ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS THESE DOORS/SIDELITES ARE RATED FOR LARGE & SMALL MISSILE IMPACT. Engr; JAVAD A6•IMAD 'a o EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. SHUTTERS ARE NOT REQUIRED. CML-• FTAs . PE 70592 0 N A. . 536 ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE C. , NOT PART OF THIS APPROVAL. A LOAD. DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. THE APPROVED PRODUCTS NOTED HEREIN ARE EXEMPT FROM PRESERVATIVE TREATMENT PER 2326.2.1 MATERIALS .INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT OF THE FLORIDA BUILDING CODE WHICH EXEMPTS WOOD SPECIES LISTED AS 'DURABLE'. drawing no. COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE THE SPECIFIC PRODUCTS HEREIN ARE EXEMPTED WOOD SPECIES BASED ON USDA LISTING AND MUST W10— 1 REQUIREMENTS OF THE FLORIDA BLDG. CODE SECTION 2003.8.4. HAVE A SPECIFIC GRAVITY EQUAL TO OR HIGHER THAN THE REFERENCED SPECIES. Y n0�� sheet of $ 4 +�J SINGLE LEAF (X) OR DOUBLE LEAF (XX) DOORS LEAF LEAF LEAF STATIONARY PANEL (0) OR DOORS EESS,IDELITES WIDTH W7 W2r-RA" W7 W2 Wi � � DESIGN LOAD CAPACITY - PSF WIDTH WIDTH WIDTH DESIGN LOAD CAPACIT � r � 1-11/16" THK 1-11/16" f IJ -4r, � THK. 4 4 i FT./IN. �..w, tI�T:EX (+)2/0 60.0 60.0 WFT. !N. FT: EXT. (+) INT. FT./IN 01 Z/0 di / . .o2/6 8/0 60.0 60.0 a-� 2/6 8/0 60.0 60.0 3/0 60.0 80.0 \ \ / 3/0 60.0 60.0 \ // \\ 0 U \ o , W7 W2 Wi� �-y-y�g }-y2-�I ® COCO I 0 ata 1H / / \ 0 WIDTH (1N} W1 + W2 Lo (FOR DOORS WITH SIDELITES) 2 u ! o `14 0 z ® .., DECORATIVE MOLDING I �OP7lONAL © ID =d Q w SOLID 1O p -6f•THK. INSERT 0 W Q SOLID W00 OR • • 3 JD LAMINATED WOOD • . = a •..••. 6D X 1-3/4" LO�-gG •.••• •tW r''" w ••.•i• BRAD NAILS . M 1" FROM ENDS .... r a:o2� :....: & 3" O.C. MAX. . _ '"•- w • • W Ali • • ••••.• r`j �`- ' �, ;�1 •• o iii � ••.•.• 1• so28 • U W PRODUCT RBVISBD U 0yin6 With the Fh*da �iv 8s Com �f a Building Coda LLJ ACCEpIBitCC No .-� Bxpi tion Bate o 15 iii Q aO Miami Dade ct Control > o GLAZING DETAIL � [ ,� m Engr: JAVAD AHMAD n o CIVIL Fl A.•PE. 70592 o M C.A N. 3 338 • v ani drawing no. W10- 1 1 LEAF WIDTH LEAF Wtt77HLEAF MnDTH LEAF WIDTH LEAF WIDTH LEAF WIDTH LEAF WIDTH LEAF' WIDTH LEAF WIDTH LEAF WIDTH �� r-7IN IL �- pq 777' Z LU pq ® O S ii tv} CJ IL W M ',w Lil ID d 0 L < 'A L1. o .6 �° r Quj 3� s �. w o N 00 z M v 0 — Uj 174 t_.� _ 0 — 1:• 9 N FM PR pq LL- ..... cid; v •. j ...... .... tE • . o i'RODUCT REVIS>;® ix z as complying With the Florida LEAF PATTERNS AS SHOWN ABOVE OR SIMILAR WITH VARIOUS FINISHES Building Code Acceptance No Z. 5�! AND DECORATIVE MOULDINGS GLAZED WITH SOLID WOOD INSERTS p c v ARE ALSO ALLOWED. Expi tion Date - 15" o a 99 N o � 0< � MINIMUM DIMENSIONS: iiami uctContro TOP AND BOTTOM RAILS.................... 5-1/2' LOCK AND HINGE STILES........................5-1/2" INTERMEDIATE STILES...............................5-1/2" Enge..JAVAt).AIIYAD ! o CIVIL FLA. PE- .# 70592 N. 0 C.A. 538 o drawing no. 10-- 11 sheet 3 of MAY 0 TPOLYURETHANE TYPICAL ANCHORS BOLT SUPPORT AT HEAD/SILL ALUM STRIKE PLATE SEE ELEV. TYPICAL ANCHOR ALUM STRAP BRACKET EMBEDED IN WOOD GLUE FOR SPACING IBY WOOD BUCK SEE ELEV. ,� 4o METAL `/ CL FASTENED WITH ACI G _ H �%l (2) #8 X 1 114" SMS e U - -- SEE C FOR SP N .-_... ,., '�� •_ L ..�. _ _; \�:..� � � URE -- _ STR CT TYPICAL ANCHORS - _ _.._: . P U) Z4 0 g 0 14 z 2 C r L1 J ce 0J1 0 MIAMI--DADE COUNTY APPROVED 0 p q a N MULLION & MULLION ANCHORS j — SEE SEPARATE NOA - spr u' ` TYPIC L ANCHORS `s' SEE ELEV. ' `yl`Z'`�_� 7 OSMS W R PACING AT 3-1/2" HFROM ENDS + `s ��`t �� \ AND 15" O.C. MAX. TYPICAL ANCHORS , SEE ELEV. FOR SPACING '~ �.. o ltt` s ii{`-0}} WOOD BUCKS AND METAL STRUCTURE NOT BY F.P.G. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM p `" �,��� i AND TRANSFER THEM TO THE BUILDING STRUCTURE. a V _ , O TYPICAL ANCHORS: SEE ELEV. FOR SPACING a w LO s.li�.� 1/4 DIA. TAPCON BY 'ITW' (FU-120 KSI, FY-92 KSI) d M „ 1/4" IA ULTRACON BY 'ELC,Q (Fu-177 KSS F -155 KSI) 0 I_' . . I SURFACE G XTS = _ INTO 2BY WOOD BUCKS OR WOOD STRUCTURES .• �• '�e •••• • pa LL "j �• r SEE SHEET 1 g 1i `< 1-1 2" MIN. PENETRATION INTO WOOD ••••• z -4V g • { © THRU 1 BY BUCKS INTO CONC. 4R MASONRY ••• 0 d. v .... r 0 1-1/4" MIN. EMBED INTO CONC. OR MASONRY •••• :I-- a'M • PSS � �l,'•;`l� R; �11�-,�L:��:: / •.... � •'`' DIRECTLY INTO CONC. OR MASONRY ..... • '� s 1�4 �� L� ` i 1-1/4" MIN. EMBED INTO CONC. OR MASONRY ••••• ...... fh #14 SMS OR SES F DRILLING SCREWS (GRADE 2 CRS) � •• )-l�.,t , ',� 1 ti•�i INTO MIAMI--DADE COUNTY APPROVED MULLIONS (MIN. INK. = 1;/8"�' � s ,i l {J �f••1tL \ •••••• INTO METAL STRUCTURES •• $ " • R STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) o P #8 X 2" FH SMS ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.) o -A7 3-1/2" FROM ENDS (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) AND 15" O.C. MAX. su TYPICAL EDGE DITAN -F z 2 -' .% INTO CONCRETE AND MASONRY = 2" MIN. INTO WOOD STRUCTURE = 1" MIN. c N N INTO METAL STRUCTURE = 3/4" MIN. go ° r 4 s Liam i' 13 CONCRETE AT HEAD, SILL OR JAMBS f c = 3000 PSI MIN. k 5 - 9 C-90 HOLLow/FILLED BLOCK AT JAMBS #'m - 2000 PSI MIN. Engra JAYAD%AHMAC r I CML s' B j FLA. PE # 705$2 °D C.A t4. 3538 PRODUCTREVISED 88 MH YIng with the Flonlda Building Code a ' o �•. a v a d 1 Acceptance No TYPICAL ANCHORS " TYPICAL ANCHORS s* don Date p` SEE ELEV. FOR SPACING POLYURETGLUE SEE ELEV: FOR SPACING drt3wing no. MI I Dade ct®n re w 10-- 1 1 DOOR UNITS SIDELITF UNITS (sheet 4 of $� 1 #8 X 2" a TYPICAL ANCHORS � 6D X 1-3/4" LONG O FH WOOD SCREWS IN PAIRS em i, SEE E' AT 12 BRAD O.C, MAX.-\ AT 13/8" FROM) AT EACH END E DS crag stF oT3-�..: R(a rt*.;x xTihTi \'\ - O — - —, 7W _QPT 9 0r n" Z N 4 N jF Q) 0 ° v } .-r":.'j���� - it j i. } t :•r". -!.,% ® �! s - T, a a` } a' 4'� t \ `' ,•!•' / 1 / /f• /• \ \ ,\ .i .l- •,.i M l"a.�. Q Q {Y�}1 2 2 8 2 Q Lu 13 10 #8X2 5 1/2" MIN. FH WOOD SCREWSH Q j INSET WIDT AT 15-3/4" FROM ENDS Q AND 8" O.C. MAX. LEAF WIDTH EXTERIOR LEAF WIDTH � I 1/4" MAX. FRAME WIDTH 0 N SHIM d O r � __ o V LO TYI'1CAL ANCHORS to SEE ELEV. ... ACTIVE LEAF C3 WM N FOR SPACING -INACTIVE LEAF J...< N to 9 •• •�N • •••• {�i • • f a •••• I— (]�,•an < •••••• � ••••• 0 r • • V. .Q .} °\. ,'\ `} aai \ .i t'�'�`'" -1�- :'..."�� _ ' i � \ as _ .. •• •• • • •••••• a— — . ,-� :} aat 't ,i .t..1_I• .-�..:`,.: _ �' �f• .'t: •i, I ` � •.`l .` -\� iR `.,� � -•-"..•;• �,!•: • • • • N • • 113Y • o 3 3 8 3 ® • WOOD BUCK '. •.•`. 5 1/2" MIN. INSET WIDTH 5 1/2" MIN. INSET WIDTH z LEAF WIDTH EXTERIOR PRODUCTR1 VISEas complying eFlot�da o o n o LEAF WIDTH Building Code 'w c o Aceegtast ee No -05' Z 1/4" MAX. FRAME WIDTH Expiration Date f a m SHIM By Mi ade uct Contro Engr: JAN AHMAD CIVIL- FLA.'PE 70592 +� 1 C.A.N. 538 drawing no. MAY Q 8 W10--- 1 1 sheet 5 of 8 i N" W �+ W a- 0 m v w a � aQ a �'° �a TYPICAL ANCHORS +W M— M OR SPACING 2 Q 3-1/2" X 1/8" d w 8 X 2" FH SMS 1/4" X 2-1/4" ITW TAPCONS � ALUM PLATE FULL LENGTH i AT 5-3/4°' FROM ENDS AT 3" FROM ENDS AND 12" O.C. MAX. 18 K 3/4" FN SMS IN PAIRS udi AND 14-1/4" O.G. MAX. � � AT 1'° FROM ENDS & 10--1/2" O.C. a to N 0 to s ® Z W � +� 19 r _v \ `� ` '' .i..1".•i"a••Nr•. t' 1 i I �, .' 1. ,,,. _ } •\ `'' '� '.�t '` • • = RC � •••••• J, `o my ? WOOD BUCK \ :\ s J ,t \" ` \ \ 1 .. 3 . . o ••.. q: _ •••• M (L �••••• POLYURETHANE 2 2 EXTERIOR 2 ••••• • • GLUE 5 1/2 MIN. 5 MIN.°'1 2 •• •••••• / 5 1/2'° MIN. •..•• • ••••:. LEAF WIDTH LEAF WIDTH • . id • • 1/SHIM FRAME WIDTH • - m SILICONE v a DOW CORNING 795 ami 2 o M z PRODUCT REVISED as complying%vith tiao Florida iri o a Building Code o o Acceptance No M-067 .Z n 9 o Exp' ti®n Date o ! < m By Dart not Control Eogr; dAVAD AHMAD ! N o CIVIL, RAI PE # 70592 C.A.N:13538. ai drawing no. W10-- 11 sheet 6 of 8 3.925� ITEM # PART # REQD. DESCRIPTION MATERIAL IsiANF./SUPPLIER/RI;hIARKS U -- " -650 M 4I D00h FRA E HEAD/JAMBB WOOD ? _ - ` ALTERNATE..TOP & BOTTOM RAIL HINGE de LOCK STILE/SIDELITE.5TILE WOOD - rr .492- / 0 0 4 - 1 SILL COVERLu ALUMINUM +- - -- 3.t40� 5;500 5 - 1 SILL FILLERt � Q WOOF? CL O i _ - W 0 coj FRAME HEAD/JAMB t2 INTERMEDIATE STILE 6 FRAMEL WOOD 7 - AS REQD. GLAZING IB - BEAD WOOD - 0 1?j — 1 ca ASTRAGAL PLYWOOD AB MARINE GRADE 13 PLY �` 1.750 1.181 9 1 ASTRAGAL INTERIOR COVER WOOD Q 10 - - 1 ASTRAGAL EXTERIOR COVER WOOD O a Q o 12 - AS REQD, NTERMEOIAT£ STILE WOOD 1.693 i ° - 13 S44 4/ LEAF : HINGE STEEL OR ST/ST DELTANA 4 fdl p 14 #10 X 3" 3/ CORNER'S FRAME ASSEMBLY. SCREWS FLAT HEAD _ e( W .`�+, 1 — lui -�1.B19 15 QEBD650 AS REQD. FRAM£ WEATiiERSTRIPPING Q—LON -- -- PVC SCHLEGEL 1 M gg Y 4.713 d 5.500W 125 GLAZING BEAD WOOD OPTIONS 1- SOUTHERN CHERRY -' 2- ANDEAN WALNUT ^ 3- TROPICAL WALNUT 1.000�- 4- WHITE OAK I 5- YESQUERO •• I SPECIFIC GRAVITY - 0.50 MIN. (E=1,400,000) p N GRADE = 2 MIN. Oo U a -moi 492 2.500 MOISTURE CONTENT 12% MAX. z M O Li xa O TOP & BOTTOM RAIL __ a Q I HINGE & LOCK STILE`SIDEUT'y ST LE - ® W� - 3 _ •� 4.000 FRAME & PANEL CORNERS SEALED WITH DUROLOK CM902 SEALANT. � � .•..•• 1.750-1 8 ASTRAGAL FRAME AND PANEL CLADDING GLUED WITH TECHNOBOND L560S. " � ��Q. ' II ' •.•• •�•(y, r4 • * I f + • V Q •ss••• ••••• 1.750 I I HINGES: 4" X 4" X .130" THK. HINGE ... �I0� y :....: 4 PER LEAF AT 9--3/4" FROM EACH END c,, •••• ((+ I j AND 25-1/2" O.C. MAX. •••• O • ..... ' 1.309 1.909 I j 4.600 ••••• •••••• — "_ 1 I I LOCKS: ••••• g • 5 500 .375 L.250 CONVENTIONAL LOCKSET WITH DEAD BOLT AT ACTIVE LEAF LOCK STILE ; • TJ + r I + KEY OPERATED ON EXTERIOR AND THUMB TURN ON INTERIOR .. •••• PASSAGE LOCK AT 36FROM BOTTOM, O • co DEAD BOLT AT 42" FROM BOTTOM ASTRAGAL INT. COVER HINGE OPTION 1 = EMTEK CORTINA KEYED ENTRY DOOR LEVERSET 5 C i v CL 13 .13" THK. STEEL OPTION 2 = KWIKSET POLO KEYED ENTRY DOOR KNOBSET - f -•492 .276 HINGE iNST LLATION ,SCREWS OPTION 3 = BALDWIN KEYED ENTRY DOOR LEVERSET Z -w wTO PANEL: (4) #12 X 1-1/4" FH SMS MANUALLY OPERATED SURFACE BOLTS BY 'DELTANA' AT TOP AND LTO FRAME: (2) #12 X 3/4" FH SMS BOTTOM OF ACTIVE LEAF. 0 O ALTERNATE 1.000 IN INNER HOLES (MUST BE ENGAGED DURING PERIODS OF HURRICANE WARNING 'N °m .� uri a O TOP & BOTTOM RAIL 10 (2) 1/4" X 2-1/4" FH TAPCON 0 a m HINGE & LOCK STILE/SIDELITE STILE ASTRAGAL EXT. COVER IN OUTER HOLES MANUALLY OPERATED CONCEALED FLUSH BOLTS 283D BY HAGER OR FPG 4.625 WITH 5/8" THROW AT TOP & BOTTOM OF, INACTIVE LEAF. $' :- Engr: JAVAO AhiMAd r A O r 1.600 � CIVIL. as comUC`i' %vith he ; m � FIA. Pe-,# 705921 as compiyijig with the)E"hnicia 1.820 �"'�'i I 900 CAM. 3538 HaildingQade �' L+062 !L.�..-.._I___'_�. e��.-6x8�5 Acecpiaute�Nq� .-p v " Y Ji f� 1.600 .295 T Ekpir ioji Date ro v H owing no. 200 2.466-�! mi i we it-t Contra SILL C VER SILL T=ILLER FRAME S(L> W 1 0—1 1 0 6063-T5 OD WOOD O WOOD o1Z sheet O� CL 5/W' WOOD DO"WEL 0 a 1.4 C � U o Qk 5" X 5/8" WOOD DOWELcY7 Q 0 tl6 Q Q / z 4( -i 0 N 0 FRAME--TOP CORNER PANEL TOP CORNER a UJ L _ 0 -if 3.p •• : '�^•T. w M •• ' INTERM EQIATE CORNER G:7 •••••• 5" X 5/8" WOOD DOWEL • •• �,� ••••.i • I - I • /./ . • _14 .. • / Q • W YY ZC5Z c iJ 2 j o r 'd '0 8 o O 4 47 ' � Y PRODUCT RRVISED Eng : JAVAD. U0 t t o as complying udth tits Fla:Fida FLA. RE%7oSs2 z Building Code G d h!- 3838'. A ptaece No —05'1 •Z 2. V h tion Date ca jar- n Dad' nc� drawing no. FAME BOTroM CORNER W1U-- 11 PANEL BOTTQM CORNE sheet $ of $