RF-15-1190 (2) ZG.
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-235009 Permit Number: RF-5-15-1190
Scheduled Inspection Date: September 11, 2015 Permit Type: Roof
Inspector: Rodriguez,Jorge
Inspection Type: Final Roof
Owner: MARINO,STEPHEN Work Classification: Tile
Job Address: 1066 NE 94 Street
Miami Shores, FL 33138- Phone Number 305-812-0629
Parcel Number 1132050120120
Project: <NONE>
Contractor: Z ROOFING AND WATERPROOFING INC Phone: (305)885-9166
Building Department Comments
RE-TRO FIT ROOF TO WALL CONECTION AND Infractio Passed Comments
INSPECTOR COMMENTS False
RE-ROOF FRONT ROOF WITH TILE
Inspector Comments
Passed
Failed
Correction
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
September 10,2015 For Inspections please call: (305)762-4949 Page 7 of 31
C I V L L Reileh Engineering Corp.
(Consulting Engineer)
2370 Southwest 123rd Avenue
Miami,Florida 33175-1174
Tel:305-823-8008/305-397-6414
ENGINEER Fax:305-823-3300/305-884-8834
Website:www.reilehengineering.com
September 9, 2015
Z Roofing and Waterproofing, Inc.
2525 West 3 Court
Hialeah, Florida 33010
Project: ROOF TILE UPLIFT TEST REPORT
Residential Home
1066 Northeast 94 Street
Miami, Florida
Information provided by client:
Permit Number: Not Provided
Date Completion: September 4, 2015
Roofing Contractor: Z Roofing and Waterproofing, Inc.
Project Number: 15-0424
(Testing Laboratory Certificate #11-0715.04)
Dear Sirs;
In accordance with your request and authorization, a representative of Reileh Engineering
Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was
performed in general accordance with Roofing Application Standard TAS No.106 -- Standard
procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically
attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 10000 square feet, and the mean height of the
roof is less than 40 feet above ground surface. The type of tile used for this project was reported to
be concrete/clay Roof Tile. This tile was reported to have been foamed in place.
At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than
one(1)tile in ten(10)of all components in the field area and one(1)the in five(5)of all tiles in the
perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2)
squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer
areas were conducted.
�� �"t"�++, rt �'�', r 41t � eke� F' �+ ,� fir-.:"��,� '$i, '7'!a i' rR iii' i t i + ";''•i'pa°✓� '"f a �
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you
have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfully submitted;
Reileh Engineering Corporation
ohamad Sonny Salleh, P.E.49014
Project Manager
TILE UPLIFT TEST
Residential Home
1066 Northeast 94 Street
Miami,Florida
Reileh Engineering Corporation--Project Number-15-0424—Page 2 of 3
Report of
TILE UPLIFT TEST
for
Residential Home
1066 Northeast 94 Street
Miami, Florida
Project Number: 15-0424
III (�� ; t` " r A 1 ii iii ii
N +� 4!h �: $ -'ty�"!411
4 F R � a L-�6 i y p ik"'�
O `. '� 7
,. Test�u bier, .,�" {, 'Vs load lb rvst
1 35 Pass
2 35 Pass
3 35 Pass
4 35 Pass
5 35 Pass
6 35 Pass
7 35 Pass
Test 1-3 Corner, 4 Ridge Caps, 5-7 Perimeter
Reileh Engineering Corporation--Project Number-15-0424—Page 3 of 3
3
3
6
2
5
1
NUMtV(X-s5f 80 5F
O i�P CAPT�Sf I OCA110N
FIM19 - O COfZ V 20 5�
COUP MIMETE� s 3 M MSV P15fANCE,a - 5' L MNM5 005 'UflLE I�-0424
f:IPG�CAP - I COM ASA- 3'X 5'
APPPDX,POOF TEST LOCA110N5 ANP IAWN510N5