Loading...
RF-15-1190 (2) ZG. Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-235009 Permit Number: RF-5-15-1190 Scheduled Inspection Date: September 11, 2015 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: MARINO,STEPHEN Work Classification: Tile Job Address: 1066 NE 94 Street Miami Shores, FL 33138- Phone Number 305-812-0629 Parcel Number 1132050120120 Project: <NONE> Contractor: Z ROOFING AND WATERPROOFING INC Phone: (305)885-9166 Building Department Comments RE-TRO FIT ROOF TO WALL CONECTION AND Infractio Passed Comments INSPECTOR COMMENTS False RE-ROOF FRONT ROOF WITH TILE Inspector Comments Passed Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. September 10,2015 For Inspections please call: (305)762-4949 Page 7 of 31 C I V L L Reileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123rd Avenue Miami,Florida 33175-1174 Tel:305-823-8008/305-397-6414 ENGINEER Fax:305-823-3300/305-884-8834 Website:www.reilehengineering.com September 9, 2015 Z Roofing and Waterproofing, Inc. 2525 West 3 Court Hialeah, Florida 33010 Project: ROOF TILE UPLIFT TEST REPORT Residential Home 1066 Northeast 94 Street Miami, Florida Information provided by client: Permit Number: Not Provided Date Completion: September 4, 2015 Roofing Contractor: Z Roofing and Waterproofing, Inc. Project Number: 15-0424 (Testing Laboratory Certificate #11-0715.04) Dear Sirs; In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground surface. The type of tile used for this project was reported to be concrete/clay Roof Tile. This tile was reported to have been foamed in place. At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than one(1)tile in ten(10)of all components in the field area and one(1)the in five(5)of all tiles in the perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2) squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer areas were conducted. �� �"t"�++, rt �'�', r 41t � eke� F' �+ ,� fir-.:"��,� '$i, '7'!a i' rR iii' i t i + ";''•i'pa°✓� '"f a � Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation ohamad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT TEST Residential Home 1066 Northeast 94 Street Miami,Florida Reileh Engineering Corporation--Project Number-15-0424—Page 2 of 3 Report of TILE UPLIFT TEST for Residential Home 1066 Northeast 94 Street Miami, Florida Project Number: 15-0424 III (�� ; t` " r A 1 ii iii ii N +� 4!h �: $ -'ty�"!411 4 F R � a L-�6 i y p ik"'� O `. '� 7 ,. Test�u bier, .,�" {, 'Vs load lb rvst 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass Test 1-3 Corner, 4 Ridge Caps, 5-7 Perimeter Reileh Engineering Corporation--Project Number-15-0424—Page 3 of 3 3 3 6 2 5 1 NUMtV(X-s5f 80 5F O i�P CAPT�Sf I OCA110N FIM19 - O COfZ V 20 5� COUP MIMETE� s 3 M MSV P15fANCE,a - 5' L MNM5 005 'UflLE I�-0424 f:IPG�CAP - I COM ASA- 3'X 5' APPPDX,POOF TEST LOCA110N5 ANP IAWN510N5