Loading...
RF-15-915 9�' �! { Miami Shores Villager 10050 N.E.2nd Avenue NE ` Miami Shores,FL 33138-0000 �� \ X7 E ` Phone: (305)795-2204 \ Expiration: 10124/201 Project Address Parcel Number Applicant l 453 NE 99 Street 1132060170410 Miami Shores, FL 33138- Block: Lot: KRISTINA M MARTINEZ Owner Information Address Phone Cell KRISTINA M MARTINEZ 453 NE 99 Street (305)234-5234 MIAMI SHORES FL 33138- 453 NE 99 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 4,500.00 ISAACS ROOFING &INSULATION COI (305)234-5234 (786)277-9756 Total Sq Feet: 700 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF FLAT TO FLAT Inspection Type: Classification:Residential Tin Cap Scanning:4 Final Roof Roof in Progress Renailing Affidavit Review Roof Fees Due Amount Pay Y Type Date Pa T e Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-4-15-55243 CCF $3.00 04/27/2015 Check#:09572 $727.50 $50.00 DBPR Fee $3.75 DCA Fee $3.75 04/17/2015 Check#:09571 $50.00 $0.00 Education Surcharge $1.00 Bond#:2689 Permit Fee-New Roof $250.00 Scanning Fee $12.00 Technology Fee $4.00 Total: $777.50 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANI L,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: Iee9fffY—_t_h"at all th regoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. hermore, I orize the above-named contractor to do the work stated. April 27, 2015 Authorized Signature- wner / Applicant / Contractor / Agent Date Building Dep nt Copy April 27, 2015 1 O� Miami Shores VillageAPS 17 ZoiS Building Department Bim. - 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 FBC 20 10 BUILDING Permit No. PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: 2�N.c Q.Q:lv, City: Miami Shores County: Miami Dade Zip: 33\ 3� Folio/Parcel#: k\- -C)`- -Qy 10 Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Tit eholder); (t r is fI iw_ f� 1i�r i r4Z Phone#: '•4 Address: '•-_3 - (-V j" ,,,,t .,,r� City:°-M, S ; VL State: Zip: 3 I Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Phone#: 2 s a3'N-5Q3A Address: \—4�'ZS -4--n, City: \ .na a 5&' �^_ State: L _ Zip: Qualifier Name: /-��c,l.,� y��'sl Phone#: _41(o WA'A- (• State Certification or Registration#: Certificate of Competency#: Contact Phone#: A (o Email Address: A\s.y Cn tc'mswc�Roecc..•�a Cd ►J\ DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 1A.jt%p(N Square/Linear Footage of Work: O V Type of Work: ❑Addition ❑Alteration ❑New Wepair/Replace ❑Demolition Description of Work: (2,c rc.(Z 04 Color thru tile: Submittal Fee$ <®d Permit Fee$;;�)_"50 -W CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ �^rl TOTAL FEE NOW DUE$ c Jy 2� 60 lRonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of'a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. --- Signature i� Signature Owner or Agent 10 Contractor The foregoing instrument was acknowledged before me this1� The foregoing instrument was acknowledged before me this):)-- day hisday of RQr',X- ,20 1!5,,by % <, day of CA.— 20!S-,by X\,:.0 �a('M'� �. ///// who is personally known to me or who has produced who is personally known to me or who has produced01 u. As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign:�- Sign: _ Print: Print: My Commias y�. N�l�FAD;193 ',,- RN Fltq l � _ Notarylic- tatida My ComLr pj} fy IicrateFlorida 4 My Comm. Expires A016 rvty Comm. Ex ire>A r 30,2016 P PCommission#k EE5 Commission #EE 19398S APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) Miami Shores Village Building Department 10050 N.E.2nd Avenue tTERiNjP' Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Y"l si f 1'1� V 1 a f-�1 i L- Z-- Property Address. 4's - K�L t t i Roofing Permit Number: Dear Building Official: I y �rj S�j rW- t-VIA144L-Z certify that I am not required to retrofit the roof to wall connections of my building because: r The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad ((valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) ,s .SAG •, ' ( ',�,� y y ` 1 ' `s�i JCA 1'V1t'r 1 ti's-Z-- Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this –A day of HANNA FADUL Notary Public state of Florida ", ' My Comm. Expires Apr 30,2016 Notary Public, Sate of Florida at Large —' s. /s Commission #EE 193985 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 4/17/2015 Property Search Application-Miami-Dade County .�: FF I E ..� PROPERTY APPRAISER Summary Report Generated On:4/17/2015 Property Information Folio: 11-3206-017-0410 Property Address: 453 NE 99 ST Owner ROMAIN A BRETON&W KRISTINA M MARTINEZ Mailing Address 453 NE 99 ST MIAMI,FL 33138 Primary Zone 1200 SGL FAMILY-2501-2800 SQ Primary Land Use 0101 RESIDENTIAL-SINGLE ` FAMILY:1 UNIT Beds/Baths/Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,586 Sq.Ft Living Area 2,011 Sq.Ft Adjusted Area 2,469 Sq.Ft Lot Size 9,775 Sq.Ft Taxable Value Information Year Built 1948 2014 2013 2012 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2014 2013 2012 Taxable Value 1 ____$265,6671 $261,002 $255,804 Land Value $205,197 $181,952 $140,111 School Board Building Value $156,333 $156,360 $174,249 Exemption Value $25,000 $25,000 $25,000 XF Value $669 $6691. $790 Taxable Value $290,6671 $286,0021 $280,804 Market Value $362,199 $338,981 $315,150 City Assessed Value 1 $315,667 $311,002 $305,804 Exemption Value $50,0001 $50,000 $50,000 Benefits Information Taxable Value 1 $265,667 $261,002 $255,804 Regional Benefit Type 2014 2013 2012 Exemption Value $50,000 $50,000 $50,000 Save Our Homes Cap Assessment Reduction $46,532 $27,979 $9,346 Taxable Value $265,6671 $261,0021 $255,804 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Sales Information Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Previous OR Book- Board,City,Regional). Sale Price Page Qualification Description 04/29/2009 $370,000 26868-2802 Qual by exam of deed i Short Legal Description 02/01/1995 $140,000 16702-0098 2008 and prior year sales;Qual by exam MIAMI SHORES SEC 4 AMD PB 15-14 of deed E45FT LOT 17&W40FT LOT 18 2008 and prior year sales;Qual by exam BLK 89 01/01/1985 $90,000 12379-1399 of deed LOT SIZE 85.000 X 115 OR 16702-0098 0295 1 08/01/1980 $115,000 108541275 afd d prior year sales;Qual by exam The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no lability,see full disclaimer and User Agreement at http://www.miamidade.gov/iinfo/disclaimer.asp Version: Secton A MIAMI•C►ADE Miami-Dade County Building Department Electronic Application MM High Velocity Hurricane Zone Roofing Permit Application Form "Oclivering Excellence Every Daly" Section A (General Information) F`19C + iV�b I' Master Permit No: Process No: APR 1 7 2��5 Contractor's Name: Isaacs Roofing BY: Job Address: 453 NE 99 St. -` Roof Category ❑✓ Low Slope ❑ Mechanically Fastened Tile ❑✓ Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: Roof Type ❑ New Roof ❑✓ Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area (ft.2) 700 Steep Sloped area (ft.2) Total (ft.2) 700 Section B(Roof Plan) ;Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include�� � € dirrlengions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. [� Perimeter Width (a'): 3 Corrter Size(a' x a'): 9a I, i i I G 5x7 drains and 5x7 } w overflow 2" min ( as t a above low point 77 U-1 w 2 0 , T 0 2 n U Q t; I T o mAF� IR AV ' Q Uj O ¢ MF inn U tjUP my I!. _.° 0 P; 77 I Section C MIAMIdXOMIE Miami-Dade County Building&Neighborhood Compliance Department HVHZ Electronic Roof Permit Form "Oeli%erif,%,Excellence ee Every E,a8 Section C page(Low Slope Roof Systems) Fill in the specific roof assembly components.If a component is not required,insert not applicable(n/a)in the text box. ROOF SYSTEM MANUFACTURER: Polyglass Top Ply: Elastoflex SAP FR Product Approval (NOA): 13-0514.10 System Type: E(1) Top Ply Fastening/Bonding Material: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: Self-Adhered (P1) Field: 42.8 psf Surfacing: n/a 71 7 SINGLE PLY MEMBRANE: (P2) Perimeters: psf Single Ply Manufacturer/Type: (P3)Comers: 108 psf n/a Maximum Design Pressure From NOA:152.5 1 1 psf Single Ply Sheet Width: "1/2 Sheet Width: Roof Slope: 1/8 ": 12 Roof Mean Height: 10 ft. No.of Single Ply 1/2 sheets: Parapet Walls: ❑No ❑✓ Yes Parapet wall Height: 2 ft. Single Ply Membrane Fastening/Bonding Material: n/a Deck Type: --1"x 6"T&G-- ❑✓ FASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: Na "o/c El SINGLE PLY MEMBRANE ATTACHMENT Alternate Deck Type: n/e 1.Field: 8 "o/c @ Laps& 2 rows 8 ` "o/c Existing Roof: n/a 2.Perimeter: 6 "o/c @ Laps&El rows "o/c Fire Barrier: n/a 3.Corner: 4 "o/c @ Laps& 6 rows 4 "o/c Vapor Barrier: NUMBER OF FASTENERS PER INSULATION BOARD: n/a 1. Field:El 2. Perimeter:El 3. Corner: Anchor Sheet: Insulation Fastener Type 75#& Elastobase n/a Anchor Sheet Fastener/Bonding Material: n/a WOOD NAILER TYPE AND SIZE: Insulation Base Layer Size&Thickness: n/a n/a Wood Nailer Fastener Type and Spacing: Insulation Base Layer Fastener/Bonding Material: n/a n/a EDGE&COPING METAL SIZES: Insulation Top Layer Size&Thickness: Edge Metal Material: --Galvanized Metal-- n/a Edge Size: --3"face 26 ga.-- Insulation Top Layer Fastener/Bonding Material: Hook Strip Size: --SELECT EDGE METAL HOOK STRIP SIZE-- n/a Edge Metal Attachment: Base Sheet(s)&No.of Ply(s): n/a 1- Elastoflex SA V FR Base Sheet Fastener/Bonding Material: Coping Material: --SELECT PARAPET WALL COPING MATERIAL-- 1 1/4"Nails and tin caps Coping Size: --SELECT COPING METAL SIZE OR THICKNESS— Ply Sheet(s)&No.of Ply(s): Hook Strip Size: --SELECT COPING METAL HOOK STRIP SIZE-- 1-Elastoflex SA V FR Parapet Coping Metal Attachment: Ply Sheet Fastener/Bonding Material: n/a self adhered N Section C2 MIIAM I-IM E Miami-Dade County Building &Neighborhood Compliance Department HVHZ Electronic Roof Permit Form "Delivering Excellence Every Oiy" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS-111 and Chapter 15 HVHZ, FBC. Polyf lex SA P T-Bar and stucco stop ElastoF'lex SA v 2' Parapet'Wall Height 5x7 scupper and overflow 2" min above low point 10' Meati Roof Height ft. 75 ## & Ela.stoba.se file:///Cl/Documents%20and%20Settings/sky/Desktop/roof%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM Rp SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner ant the contractor,The owner's initial in the designated space indicates that the item has been explained. 1. - Aesthetics-Workmanship:the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. 2. .Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be 2renaile'd in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system). 3. —!��Common roofs:Common roofs are those which have no visible delineation between neighboring units(i.e.,townhouses,condominiums,etc.)In buildings with common roofs,the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. 410Exposed Ceiling: Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail penetration of the underside of the decking may not be acceptable.This provides the option of maintaining the appearance.y� 5. -/"R -Ponding water:The current roof system and/or deck of the building may not drain well and may cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer.Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water.Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accor aannc'e with the requirements of Sections R4402, R4403 and R4413. 7. ° Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. _ 1 /f,� ��✓mom Owner/Agent's Signature to Contractor Signature Date Revised on 7/9/2009 LD MIAM ' MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE NOA www.miamidade.aov/cconom Polyglass USA,Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA4 13-0514.10 and consists ofe a p g s 1 through ough 33. The submitted documentation was reviewed by Alex Tigera. M1AM1•D140E COU rmr NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/.14 Page I of 33 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateaory: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE X Test Product Product Dimensions Specification Description Elastobase 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type [ base sheet. XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type[ base sheet. Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet Type II Polyanchor 250' x 48" ASTM D 4601 A polymer woven,high performance, synthetic base Type II sheet. Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced, SBS (1.5-mm) Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced, SBS PLUS FR Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V(1.5- 66' 8"x 3' 3-'/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified mm) Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 32/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified PLUS Type i bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8"x 3' 32/$" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified SA Type 1 bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated, polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. MMICADecour�rY NOANo.; 13-1217.0I �S ""• * Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 2 of 33 Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32' 10"x 3'3-3/8" ASTM D 6222 Torch applied, polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced APP modified pP ,P y bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10"x 3 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex SA P 32' 10"x 3' 32/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32' 10"x 3' 3-34" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex APP G SA 32' 10"x 3' 3-3/S" ASTM D 6222, Self-adhered, fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 3-3/$" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 3,3/8" ASTM D 6164, Self-adhered, fire-rated, fiberglass reinforced, SBS FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 3-34" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 3-'/s" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32' 10"x 3' 3-3/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Koo1 APP S 32' 10"x 3' 3'/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 3'/$" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type I base sheet. MIAWDADEGOUNTY NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 3 of 33 PG325 Cold Process I,3,5, 50,55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type TTI BUR roofing. PG100 Asphalt Primer 1,3, 5,50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz. r sp ay selected asphalts used top romote adhesion. can XtraFlex 10 Asphalt 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of Primer tube or 17 oz. spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1,3,5, 50,55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type III modified bitumen membranes. PG400 Plastic Roof 1,3, 5,50,55 gal.or ASTM D4586 A thick,fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1,3,5, 50,55 gal.or ASTM D4586 A thick, fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG450 Flashing 1,3,5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement. Cement tube PG500 MB Flashing 1,3, 5,50, 55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1,3,5,50,55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. XtraFlex 35 Premium 1,3, 5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. Polyplus 45 Premium 1,3,5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement. Flashing Cement tube Polyplus 50 Premium 1,3,5,50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. XtraFlex 50 Premium 1,3, 5,50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use Modified Wet/Dry tube with modified bitumen membranes. Cement Polyplus 55 Premium 1,3,5, 50,55 gal. or ASTM D4586 A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement CMIAMI-MDADMECOUNTY NOA No.: 13-1217,01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 4 of 33 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA Polytherm-H Polyisocyanurate foam insulation Polyglass USA,Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA,Inc. ACFoam-Il Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-IlI Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3,JM ISO 3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation AMMDADECOUN7Y NOA No.: 13-1217.01 �uumfing Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 5 of 33 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1_ Dekfast Fasteners 12, 14 & Insulation fastener for wood, SFS Intec,Inc. 15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2'/s"x SFS Intec,Inc. Hex Plate 3 '/4" 3. 414 Roofgrip Insulation and membrane Various OMG,Inc. fastener 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3"square OMG,Inc. 5. Trufast 414 HD Fastener insulation fastener for steel and Altenloh,Brinck&Co. wood decks U.S.,Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co. Plate plate 3" round U.S.,Inc. 7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various Polyglass USA, Inc &415 steel and concrete decks 8. Polygrip Hex Plates Galvalume hex stress plate. 2 '/8"x Polyglass USA, Inc 3 '/4" MtAMI•DADE COUNTY NOA No.: 13-1217.01 •.•+ ► Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 6 of 33 APPROVED SURFACING: TABLE 4 Product Product Application Manufactur Name Description Rate Specification er PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1%-2 gal/sq TAS 140 Polyglass to add life and rejuvenate existing USA, Inc. BUR roofing substrates. XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used I%z-2 gal/sq TAS 140 Polyglass Coating to add life and rejuvenate existing USA,Inc, BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof I%z-2 gal/sq ASTM D4479 Polyglass coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR XtraFlex Bituminous Roof An asphalt cutback fibered roof I%z-2 gal/sq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. %z-1 gal/sq ASTM D2824 Polyglass Roof Coating Type I USA, Inc. PG650 Fibered Aluminum Roof Fibered aluminum roof coating. I'/z-2 gal/sq ASTM D2824 Polyglass Coating Type III USA,Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/z gal/sq ASTM D6083 Polyglass based roof coating(water-based). A USA Inc. polyester fabric may be used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Emulsion Roof Coating emulsion two coats USA,Inc. XtraFlex 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Coating emulsion two coats USA,Inc, PG850 Fibered Asphalt Emulsion An asphalt base,Fibered clay 3 gal/sq in ASTM D1227 Polyglass Roof Coating emulsion two coats USA,Inc. Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1%z-2 gal/sq ASTM D2824 Polyglass Aluminum Roof Coating Type III USA,Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass Coating Fibered Type III USA,Inc. Polyplus 60 Premium Non- Non-fibered aluminum roof coating. %z-1 gal/sq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA, Inc. XtraFlex 60 Aluminum Roof Non-Fibered aluminum roof _ coating. h 1 gal/sq ASTM D2$24 Polyglass Coating Type I USA,Inc, MIAMI-DAD na� ou�r< N ANo.: 13-1217.01 1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 7 of 33 APPROVED SURFACING: TABLE 4 Product Product Application Manufactur Name Description Rate Specification er Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 Polyglass Elastomeric Roof Coating based roof coating(water- based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/Z gal/sq ASTM D6083 Polyglass Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. Polybrite 90 High Solids Silicone A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass Roof Coating component, moisture cure,fluid USA.Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating Polybrite 95 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. XtraFlex SRC 8000 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. Gravel To be installed in a flood coat of 400 lbs/sq N/A Generic approved asphalt at 60 lbs/sq Slag To be installed in aflood coat of 300 lbs/sq N/A Generic approved asphalt at 60 lbs/sq MfAMI•DAbE COUNTY NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 8 of 33 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3001334 02.15.00 4470 3000857 01.I2.00 4470 3004091 01,12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity,ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-R1 02.27.07 TAS 114 P1.738.02.07 02.05.07 TAS 114 P1739,01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164/ASTM D6222 P10490.08.08 08.13.08 ASTM D6164/ASTM D6222 P10490.10.08-RI 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D)—ASTM DI 876 P10070.10.08 10.09.08 ASTM D6222 P10490.10.08-2 10.30.08 FM 4470&TAS 114 P33970.03.1 1 03.15.11 ASTM D6163/ASTM D 4601 P33960.03.11 03.15.11 TAS 114&TAS 117(B) 11757.12.00-1-R1 04.29.13 TAS 114&TAS 1 17(B) 11757.04.01-1-RI 04.30.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03,13-3A 03.06.13 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 /TAS 117 P45940.09.13 09,04.13 TAS 114&FM 4474 P41630.08.13 08.06.13 TAS 114(H) P13760.09.09 09.10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-1 34-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 MIAMI•DADECOUNTY NOA No.: 13-1217.01 "'' — Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 9 of 33 Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 1962" or greater plywood or wood plank. System Type E(1): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase,XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening#1: Attach base sheet using I I ga.annular ring shank nails and 1-5/8"diameter tin caps spaced 8" o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet. Fastening#2: Attach base sheet using OMG 914 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast #14 with Dekfast Galvalume Steel Hex Plates,Polygrip Fasteners#14 with Polygrip Hex Plates or Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates spaced 12"o.c. in a 4" lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. PIy Sheet: One or more plies of Elastoflex SA V(1.5-mm),Elastoflex SA V PLUS,XtraFlex SBS Base SA,Elastoflex SA V FR(1.5-mm)or Elastoflex SA V PLUS FR,self-adhered. Membrane: One ply of Polyfresko G SBS SA,Polyfresko G SBS SA FR,Polyfresko G APP SA, Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP G SA,self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf,(See General limitation#7.). MuuHi-aAoe courmr NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 26 of 33 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8" ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq: Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 IV., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lb£ insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation 99 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners).(When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products Iisted herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI•t)ADECOfjNTy OA No.: 13-1217.01. •mo Expiration Date: 10/11/17 Approval Date:11/06/14 Page 33 of 33 POLYGLASS USA INC R14571 150 LYON DR FERNLEY,NV 84408 USA SINGLE PLY MEMBRANE SYSTEMS Class A-Fully Adhered Deck:C-I5/32 Incline:2 I tion(Optional):--Polyisocyanurate,perlite,wood fiber or palyisocyanuratefperlite board,any thickness. Barrier Board:-- in.(min)G-P Gypsum DensDeckO?mechanically fastened with all joints staggered 6 in.from the p ' d joints. Base Sheet:—"ELASTOBASE" sand),mechanically fastened or"ELASTOFLEX SA V PLUS FR","ELASTOFLEX SA V FR"or"ELA LEX SA V FR BASE VENT"(self adhered). Ply Sheet(Optional),—"ELASTOFLEX SAV R","ELASTOFLEX SA V FR"or "ELASTOFLEX SA V FR BASE VENT",(self adhered). Membrane:---"POLYFLEX SA P FR"_ "POLYFRESKO APP SA " "ELASTOFLFX SA P FR", "POLYFRESKO SB S SA P FR", "ELAS T OFLEX SAV FR HT",(self adher r"POLYFLEX G FR", "POLYFRESKO TORCH FR","DiUFLEX G FR","ELASTOFLEX S6 G FR>', R]~SICO MOP FR "ELASTOPLEX VG FR"or"BLASTOSHIELD TS GFR",heat fused 22.Deck:C-15/32 Incii;ne: 1/2 Insulation(Optional):—Poly isocyanurate 1.5 in.(min.)with all joints staggered 6-in.(min.)from the plywood joints, Base Sheet:---Ty)e G2,mechanically fastened followed by"ELASTOBASE" mechanically fastened. Ply Sheet(Optional):—"ELASTOFLEX SAV PLUS - "ELASTOFLEX SA V FR"or "ELASTOFLEX SA V FR BASE VENT ',(self adhered) Membrane:---"POLYFLEX SA P FR","POLYFRESKO APP SA P FR", "ELASTOFLEX SAP FR", "POLYFRESKO SBS_SAP FR",or"DUFLEX G FR","POLYFLEX G FR","ELASTOFLEX S6 G FR", "POLYFRESKO MOPFRI', "ELASTOFLEX VG FR"or"ELASTOSHIELD TS G FR",heat fused. ®2012 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information,Designs and/or Listings(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data(or drawings).2. The statement"Reprinted from the Online Certifications Directory with permission from UL"must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice in the following format:"®2012 UL LLC"_