RF-15-915 9�' �! { Miami Shores Villager
10050 N.E.2nd Avenue NE `
Miami Shores,FL 33138-0000 ��
\ X7
E ` Phone: (305)795-2204 \
Expiration:
10124/201
Project Address Parcel Number Applicant
l 453 NE 99 Street 1132060170410
Miami Shores, FL 33138- Block: Lot: KRISTINA M MARTINEZ
Owner Information Address Phone Cell
KRISTINA M MARTINEZ 453 NE 99 Street (305)234-5234
MIAMI SHORES FL 33138-
453 NE 99 Street
MIAMI SHORES FL 33138-
Contractor(s) Phone Cell Phone Valuation: $ 4,500.00
ISAACS ROOFING &INSULATION COI (305)234-5234 (786)277-9756
Total Sq Feet: 700
Type of Work:Re Roof Available Inspections:
Additional Info:RE ROOF FLAT TO FLAT
Inspection Type:
Classification:Residential
Tin Cap
Scanning:4 Final Roof
Roof in Progress
Renailing Affidavit
Review Roof
Fees Due Amount Pay Y Type Date Pa T e Amt Paid Amt Due
Bond Type-Contractors Bond $500.00 Invoice# RF-4-15-55243
CCF $3.00 04/27/2015 Check#:09572 $727.50 $50.00
DBPR Fee $3.75
DCA Fee $3.75 04/17/2015 Check#:09571 $50.00 $0.00
Education Surcharge $1.00 Bond#:2689
Permit Fee-New Roof $250.00
Scanning Fee $12.00
Technology Fee $4.00
Total: $777.50
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANI L,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: Iee9fffY—_t_h"at all th regoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. hermore, I orize the above-named contractor to do the work stated.
April 27, 2015
Authorized Signature- wner / Applicant / Contractor / Agent Date
Building Dep nt Copy
April 27, 2015 1
O�
Miami Shores VillageAPS 17 ZoiS
Building Department Bim. -
10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel: (305)795.2204 Fax: (305)756.8972
INSPECTION'S PHONE NUMBER: (305)762.4949
FBC 20 10
BUILDING Permit No.
PERMIT APPLICATION Master Permit No.
Permit Type: BUILDING ROOFING
JOB ADDRESS: 2�N.c Q.Q:lv,
City: Miami Shores County: Miami Dade Zip: 33\ 3�
Folio/Parcel#: k\- -C)`- -Qy 10
Is the Building Historically Designated:Yes NO Flood Zone:
OWNER:Name(Fee Simple Tit eholder); (t r is fI iw_ f� 1i�r i r4Z Phone#:
'•4
Address: '•-_3 - (-V j" ,,,,t
.,,r�
City:°-M, S ; VL State: Zip: 3 I
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR:Company Name: Phone#: 2 s a3'N-5Q3A
Address: \—4�'ZS -4--n,
City: \ .na a 5&' �^_ State: L _ Zip:
Qualifier Name: /-��c,l.,� y��'sl Phone#: _41(o WA'A- (•
State Certification or Registration#: Certificate of Competency#:
Contact Phone#: A (o Email Address: A\s.y Cn tc'mswc�Roecc..•�a Cd ►J\
DESIGNER: Architect/Engineer: Phone#:
Value of Work for this Permit: $ 1A.jt%p(N Square/Linear Footage of Work: O V
Type of Work: ❑Addition ❑Alteration ❑New Wepair/Replace ❑Demolition
Description of Work: (2,c rc.(Z 04
Color thru tile:
Submittal Fee$ <®d Permit Fee$;;�)_"50 -W CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Bond$
Notary$ Training/Education Fee$ Technology Fee$
Double Fee$ Structural Review$ �^rl
TOTAL FEE NOW DUE$ c Jy
2� 60
lRonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of'a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
---
Signature i� Signature
Owner or Agent 10
Contractor
The foregoing instrument was acknowledged before me this1� The foregoing instrument was acknowledged before me this):)--
day
hisday of RQr',X- ,20 1!5,,by % <, day of CA.— 20!S-,by X\,:.0 �a('M'� �. /////
who is personally known to me or who has produced who is personally known to me or who has produced01
u.
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign:�- Sign: _
Print: Print:
My Commias y�. N�l�FAD;193
',,- RN Fltq
l � _ Notarylic- tatida My ComLr
pj} fy IicrateFlorida
4 My Comm. Expires A016 rvty Comm. Ex ire>A r 30,2016
P PCommission#k EE5 Commission #EE 19398S
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
tTERiNjP' Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: Y"l si f 1'1� V 1 a f-�1 i L- Z--
Property Address. 4's - K�L t t i
Roofing Permit Number:
Dear Building Official:
I y �rj S�j rW- t-VIA144L-Z certify that I am not required to retrofit the roof to wall connections of my
building because:
r The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
((valorem taxation.
❑The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
,s .SAG •, ' ( ',�,� y y ` 1 ' `s�i JCA 1'V1t'r 1 ti's-Z--
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this –A day of
HANNA FADUL
Notary Public state of Florida
", ' My Comm. Expires Apr 30,2016
Notary Public, Sate of Florida at Large —' s. /s
Commission #EE 193985
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
4/17/2015 Property Search Application-Miami-Dade County
.�: FF I E
..� PROPERTY
APPRAISER
Summary Report
Generated On:4/17/2015
Property Information
Folio: 11-3206-017-0410
Property Address: 453 NE 99 ST
Owner ROMAIN A BRETON&W
KRISTINA M MARTINEZ
Mailing Address 453 NE 99 ST
MIAMI,FL 33138
Primary Zone 1200 SGL FAMILY-2501-2800 SQ
Primary Land Use 0101 RESIDENTIAL-SINGLE `
FAMILY:1 UNIT
Beds/Baths/Half 3/2/0
Floors 1
Living Units 1
Actual Area 2,586 Sq.Ft
Living Area 2,011 Sq.Ft
Adjusted Area 2,469 Sq.Ft
Lot Size 9,775 Sq.Ft Taxable Value Information
Year Built 1948 2014 2013 2012
County
Assessment Information Exemption Value $50,000 $50,000 $50,000
Year 2014 2013 2012 Taxable Value 1 ____$265,6671 $261,002 $255,804
Land Value $205,197 $181,952 $140,111 School Board
Building Value $156,333 $156,360 $174,249 Exemption Value $25,000 $25,000 $25,000
XF Value $669 $6691. $790 Taxable Value $290,6671 $286,0021 $280,804
Market Value $362,199 $338,981 $315,150 City
Assessed Value 1 $315,667 $311,002 $305,804 Exemption Value $50,0001 $50,000 $50,000
Benefits Information Taxable Value 1 $265,667 $261,002 $255,804
Regional
Benefit Type 2014 2013 2012 Exemption Value $50,000 $50,000 $50,000
Save Our Homes Cap Assessment Reduction $46,532 $27,979 $9,346 Taxable Value $265,6671 $261,0021 $255,804
Homestead Exemption $25,000 $25,000 $25,000
Second Homestead Exemption $25,000 $25,000 $25,000 Sales Information
Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Previous OR Book-
Board,City,Regional). Sale Price Page Qualification Description
04/29/2009 $370,000 26868-2802 Qual by exam of deed
i Short Legal Description
02/01/1995 $140,000 16702-0098 2008 and prior year sales;Qual by exam
MIAMI SHORES SEC 4 AMD PB 15-14 of deed
E45FT LOT 17&W40FT LOT 18 2008 and prior year sales;Qual by exam
BLK 89 01/01/1985 $90,000 12379-1399 of deed
LOT SIZE 85.000 X 115
OR 16702-0098 0295 1 08/01/1980 $115,000 108541275 afd d prior year sales;Qual by exam
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property
Appraiser and Miami-Dade County assumes no lability,see full disclaimer and User Agreement at http://www.miamidade.gov/iinfo/disclaimer.asp
Version:
Secton A
MIAMI•C►ADE Miami-Dade County Building Department Electronic Application
MM High Velocity Hurricane Zone Roofing Permit Application Form
"Oclivering Excellence Every Daly"
Section A (General Information) F`19C + iV�b
I' Master Permit No: Process No: APR 1 7 2��5
Contractor's Name: Isaacs Roofing
BY:
Job Address: 453 NE 99 St. -`
Roof Category
❑✓ Low Slope ❑ Mechanically Fastened Tile ❑✓ Mortar/Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Sprayed Polyurethane Foam ❑ Other:
Roof Type
❑ New Roof ❑✓ Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance
Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No If yes, what type? ❑ Natural ❑ LPGX
Roof System Information
Low slope roof area (ft.2) 700 Steep Sloped area (ft.2) Total (ft.2) 700
Section B(Roof Plan)
;Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include�� �
€ dirrlengions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. [�
Perimeter Width (a'): 3 Corrter Size(a' x a'): 9a
I,
i
i
I G
5x7 drains and 5x7
} w overflow 2" min
( as
t a above low point
77
U-1 w 2 0
, T
0 2 n U Q
t; I T
o mAF� IR AV
' Q Uj
O ¢ MF inn U
tjUP my
I!. _.° 0 P; 77
I
Section C
MIAMIdXOMIE Miami-Dade County Building&Neighborhood Compliance Department
HVHZ Electronic Roof Permit Form
"Oeli%erif,%,Excellence ee Every E,a8 Section C page(Low Slope Roof Systems)
Fill in the specific roof assembly components.If a component is not required,insert not applicable(n/a)in the text box.
ROOF SYSTEM MANUFACTURER: Polyglass Top Ply:
Elastoflex SAP FR
Product Approval (NOA): 13-0514.10 System Type: E(1) Top Ply Fastening/Bonding Material:
Wind Uplift Pressures, From RAS 128 or Sealed Calculations: Self-Adhered
(P1) Field: 42.8 psf Surfacing: n/a
71 7 SINGLE PLY MEMBRANE:
(P2) Perimeters: psf
Single Ply Manufacturer/Type:
(P3)Comers: 108 psf n/a
Maximum Design Pressure From NOA:152.5 1 1 psf
Single Ply Sheet Width: "1/2 Sheet Width:
Roof Slope: 1/8 ": 12 Roof Mean Height: 10 ft. No.of Single Ply 1/2 sheets:
Parapet Walls: ❑No ❑✓ Yes Parapet wall Height: 2 ft. Single Ply Membrane Fastening/Bonding Material:
n/a
Deck Type: --1"x 6"T&G--
❑✓ FASTENER SPACING FOR BASESHEET ATTACHMENT
Support Spacing: Na "o/c
El SINGLE PLY MEMBRANE ATTACHMENT
Alternate Deck Type: n/e 1.Field: 8 "o/c @ Laps& 2 rows 8 ` "o/c
Existing Roof:
n/a 2.Perimeter: 6 "o/c @ Laps&El rows "o/c
Fire Barrier:
n/a 3.Corner: 4 "o/c @ Laps& 6 rows 4 "o/c
Vapor Barrier: NUMBER OF FASTENERS PER INSULATION BOARD:
n/a 1. Field:El 2. Perimeter:El 3. Corner:
Anchor Sheet: Insulation Fastener Type
75#& Elastobase n/a
Anchor Sheet Fastener/Bonding Material:
n/a WOOD NAILER TYPE AND SIZE:
Insulation Base Layer Size&Thickness: n/a
n/a
Wood Nailer Fastener Type and Spacing:
Insulation Base Layer Fastener/Bonding Material: n/a
n/a EDGE&COPING METAL SIZES:
Insulation Top Layer Size&Thickness: Edge Metal Material: --Galvanized Metal--
n/a Edge Size: --3"face 26 ga.--
Insulation Top Layer Fastener/Bonding Material: Hook Strip Size: --SELECT EDGE METAL HOOK STRIP SIZE--
n/a Edge Metal Attachment:
Base Sheet(s)&No.of Ply(s): n/a
1- Elastoflex SA V FR
Base Sheet Fastener/Bonding Material: Coping Material: --SELECT PARAPET WALL COPING MATERIAL--
1 1/4"Nails and tin caps Coping Size: --SELECT COPING METAL SIZE OR THICKNESS—
Ply Sheet(s)&No.of Ply(s): Hook Strip Size: --SELECT COPING METAL HOOK STRIP SIZE--
1-Elastoflex SA V FR Parapet Coping Metal Attachment:
Ply Sheet Fastener/Bonding Material: n/a
self adhered
N
Section C2
MIIAM I-IM E Miami-Dade County Building &Neighborhood Compliance Department
HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Oiy"
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base
Flashing, Counterflashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material
Thickness, Fastener Type, Fastener Spacing
Or: Submit Manufacturers Details that Comply with RAS-111 and Chapter 15 HVHZ, FBC.
Polyf lex SA P
T-Bar and stucco
stop
ElastoF'lex
SA v
2'
Parapet'Wall Height
5x7 scupper and
overflow 2" min
above low point
10'
Meati Roof Height ft.
75 ## &
Ela.stoba.se
file:///Cl/Documents%20and%20Settings/sky/Desktop/roof%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM
Rp
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally,the following items should be addressed as part of the agreement between the owner ant the
contractor,The owner's initial in the designated space indicates that the item has been explained.
1. - Aesthetics-Workmanship:the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues
such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of
the agreement between the owner and the contractor.
2. .Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be
2renaile'd in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior
to removing the existing roof system).
3. —!��Common roofs:Common roofs are those which have no visible delineation between neighboring
units(i.e.,townhouses,condominiums,etc.)In buildings with common roofs,the roofing contractor and/or
owner should notify the occupants of adjacent units of roofing to be performed.
4. 410Exposed Ceiling: Exposed,open beam ceilings are where the underside of the roof decking can
be viewed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail
penetration of the underside of the decking may not be acceptable.This provides the option of maintaining the
appearance.y�
5. -/"R -Ponding water:The current roof system and/or deck of the building may not drain well and may
cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer.Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water.Perimeter/edge wall or other roof extension may block this discharge if
overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in
accor aannc'e with the requirements of Sections R4402, R4403 and R4413.
7. ° Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of the
roof. _
1
/f,� ��✓mom
Owner/Agent's Signature to Contractor Signature Date
Revised on 7/9/2009 LD
MIAM
' MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE NOA www.miamidade.aov/cconom
Polyglass USA,Inc.
150 Lyon Drive
Fernley,NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA4 13-0514.10
and consists ofe a
p g s 1 through ough 33.
The submitted documentation was reviewed by Alex Tigera.
M1AM1•D140E COU rmr
NOA No.: 13-1217.01
Expiration Date: 10/11/17
Approval Date: 11/06/.14
Page I of 33
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Cateaory: Modified Bitumen
Materials SBS/APP/TPO
Deck Type: Wood
Maximum Design Pressure -112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED
OR LABELED BY APPLICANT:
TABLE X
Test Product
Product Dimensions Specification Description
Elastobase 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced
Type [ base sheet.
XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced
Base Type[ base sheet.
Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet
Type II
Polyanchor 250' x 48" ASTM D 4601 A polymer woven,high performance, synthetic base
Type II sheet.
Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base
Type I sheet.
Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced, SBS
(1.5-mm) Type I modified bitumen membrane with a self-adhering back
face and a smooth top surface.
Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced, SBS
PLUS FR Type I modified bitumen membrane with a self-adhering back
face and a smooth top surface.
Elastoflex SA V(1.5- 66' 8"x 3' 3-'/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified
mm) Type I bitumen membrane with a self-adhering back face and
a smooth top surface.
Elastoflex SA V 66' 8"x 3' 32/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified
PLUS Type i bitumen membrane with a self-adhering back face and
a smooth top surface.
XtraFlex SBS Base 66' 8"x 3' 32/$" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified
SA Type 1 bitumen membrane with a self-adhering back face and
a smooth top surface.
Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated, polyester reinforced, SBS
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
MMICADecour�rY NOANo.; 13-1217.0I
�S ""• * Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 2 of 33
Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
Polyflex 32' 10"x 3'3-3/8" ASTM D 6222 Torch applied, polyester reinforced,APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced APP modified
pP ,P y
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polyflex G 32' 10"x 3 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
Polyflex SA P 32' 10"x 3' 32/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
Polyflex SA P FR 32' 10"x 3' 3-34" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
XtraFlex APP G SA 32' 10"x 3' 3-3/S" ASTM D 6222, Self-adhered, fire-rated,polyester reinforced,APP
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
Polyfresko G SBS SA 32' 10"x 3' 3-3/$" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
Polyfresko G SBS SA 32' 10"x 3' 3,3/8" ASTM D 6164, Self-adhered, fire-rated, fiberglass reinforced, SBS
FR Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
Polyfresko G APP SA 32' 10"x 3' 3-34" ASTM D 6222, Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
Polyfresko G APP SA 32' 10"x 3' 3-'/s" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP
FR Type I modified bitumen membrane with a self-adhering back
face and a granule top surface
PolyKool 32' 10"x 3' 3-3/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and
a white film laminate on the top surface.
XtraFlex Koo1 APP S 32' 10"x 3' 3'/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified
SA Type I bitumen membrane with a self-adhering back face and
a white film laminate on the top surface.
Polyglass APP Base 65' 8"x 3' 3'/$" ASTM D 6509 APP modified asphalt coated fiberglass reinforced
Type I base sheet.
MIAWDADEGOUNTY NOA No.: 13-1217.01
Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 3 of 33
PG325 Cold Process I,3,5, 50,55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or
Adhesive tube Type TTI BUR roofing.
PG100 Asphalt Primer 1,3, 5,50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of
tube or 17 oz. r
sp ay selected asphalts used top romote adhesion.
can
XtraFlex 10 Asphalt 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of
Primer tube or 17 oz. spray selected asphalts used to promote adhesion.
can
PG350 Mod Bit 1,3,5, 50,55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with
Adhesive tube Type III modified bitumen membranes.
PG400 Plastic Roof 1,3, 5,50,55 gal.or ASTM D4586 A thick,fibered, rubberized flashing cement for use in
Cement tube ASTM D3409 dry or damp conditions.
PG425 Wet/Dry Roof 1,3,5, 50,55 gal.or ASTM D4586 A thick, fibered, rubberized flashing cement for use in
Cement tube ASTM D3409 dry or damp conditions.
PG450 Flashing 1,3,5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement.
Cement tube
PG500 MB Flashing 1,3, 5,50, 55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use
Cement tube with modified bitumen membranes.
Polyplus 35 Premium 1,3,5,50,55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with
Mod Bit Adhesive tube Type III modified bitumen membranes.
XtraFlex 35 Premium 1,3, 5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with
Mod Bit Adhesive tube Type III modified bitumen membranes.
Polyplus 45 Premium 1,3,5, 50, 55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement.
Flashing Cement tube
Polyplus 50 Premium 1,3,5,50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use
MB Flashing Cement tube with modified bitumen membranes.
XtraFlex 50 Premium 1,3, 5,50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use
Modified Wet/Dry tube with modified bitumen membranes.
Cement
Polyplus 55 Premium 1,3,5, 50,55 gal. or ASTM D4586 A mastic compound for use as a roof flashing
Modified Flashing tube adhesive.
Cement
CMIAMI-MDADMECOUNTY NOA No.: 13-1217,01
Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 4 of 33
APPROVED INSULATIONS:
TABLE 2
Product
Name Product Description Manufacturer
(With Current NOA
Polytherm-H Polyisocyanurate foam insulation Polyglass USA,Inc.
Polytherm Polyisocyanurate foam insulation Polyglass USA,Inc.
ACFoam-Il Polyisocyanurate foam insulation Atlas Roofing Corp
ACFoam-IlI Polyisocyanurate foam insulation Atlas Roofing Corp
High Density Wood Fiberboard Wood fiber insulation board Generic
DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC
H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC
ENRGY-3,JM ISO 3 Polyisocyanurate foam insulation Johns Manville Corp.
Fesco Board Expanded mineral fiber Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC.
SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum
Corporation
AMMDADECOUN7Y
NOA No.: 13-1217.01
�uumfing Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 5 of 33
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1_ Dekfast Fasteners 12, 14 & Insulation fastener for wood, SFS Intec,Inc.
15 HS steel and concrete decks
2. Dekfast Galvalume Steel Galvalume hex stress plate. 2'/s"x SFS Intec,Inc.
Hex Plate 3 '/4"
3. 414 Roofgrip Insulation and membrane Various OMG,Inc.
fastener
4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3"square OMG,Inc.
5. Trufast 414 HD Fastener insulation fastener for steel and Altenloh,Brinck&Co.
wood decks U.S.,Inc.
6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co.
Plate plate 3" round U.S.,Inc.
7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various Polyglass USA, Inc
&415 steel and concrete decks
8. Polygrip Hex Plates Galvalume hex stress plate. 2 '/8"x Polyglass USA, Inc
3 '/4"
MtAMI•DADE COUNTY
NOA No.: 13-1217.01
•.•+ ► Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 6 of 33
APPROVED SURFACING:
TABLE 4
Product Product Application Manufactur
Name Description Rate Specification er
PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1%-2 gal/sq TAS 140 Polyglass
to add life and rejuvenate existing USA, Inc.
BUR roofing substrates.
XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used I%z-2 gal/sq TAS 140 Polyglass
Coating to add life and rejuvenate existing USA,Inc,
BUR roofing substrates.
PG300 Fibered Roof Coating An asphalt cutback fibered roof I%z-2 gal/sq ASTM D4479 Polyglass
coating. May be applied by brush or USA,Inc.
spray equipment to rejuvenate aged
BUR
XtraFlex Bituminous Roof An asphalt cutback fibered roof I%z-2 gal/sq ASTM D4479 Polyglass
Coating Fibered coating. May be applied by brush or USA,Inc.
spray equipment to rejuvenate aged
BUR
PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. %z-1 gal/sq ASTM D2824 Polyglass
Roof Coating Type I USA, Inc.
PG650 Fibered Aluminum Roof Fibered aluminum roof coating. I'/z-2 gal/sq ASTM D2824 Polyglass
Coating Type III USA,Inc.
PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/z gal/sq ASTM D6083 Polyglass
based roof coating(water-based). A USA Inc.
polyester fabric may be used for
reinforcement with this coating.
PG800 Non-Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass
Emulsion Roof Coating emulsion two coats USA,Inc.
XtraFlex 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass
Coating emulsion two coats USA,Inc,
PG850 Fibered Asphalt Emulsion An asphalt base,Fibered clay 3 gal/sq in ASTM D1227 Polyglass
Roof Coating emulsion two coats USA,Inc.
Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1%z-2 gal/sq ASTM D2824 Polyglass
Aluminum Roof Coating Type III USA,Inc.
XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass
Coating Fibered Type III USA,Inc.
Polyplus 60 Premium Non- Non-fibered aluminum roof coating. %z-1 gal/sq ASTM D2824 Polyglass
Fibered Aluminum Roof Coating Type I USA, Inc.
XtraFlex 60 Aluminum Roof Non-Fibered aluminum roof _
coating. h 1 gal/sq ASTM D2$24 Polyglass
Coating Type I USA,Inc,
MIAMI-DAD na� ou�r< N ANo.: 13-1217.01
1217.01
Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 7 of 33
APPROVED SURFACING:
TABLE 4
Product Product Application Manufactur
Name Description Rate Specification er
Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 Polyglass
Elastomeric Roof Coating based roof coating(water-
based). A USA,Inc.
polyester fabric may be used for
reinforcement with this coating.
XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/Z gal/sq ASTM D6083 Polyglass
Roof Coating based roof coating(water-based). A USA,Inc.
polyester fabric may be used for
reinforcement with this coating.
Polybrite 90 High Solids Silicone A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass
Roof Coating component, moisture cure,fluid USA.Inc.
applied silicone coating
XtraFlex SRC 9600 High Solids A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass
Silicone Roof Coating component,moisture cure,fluid USA,Inc.
applied silicone coating
Polybrite 95 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass
Coating moisture cure silicone coating. USA,Inc.
XtraFlex SRC 8000 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass
Coating moisture cure silicone coating. USA,Inc.
Gravel To be installed in a flood coat of 400 lbs/sq N/A Generic
approved asphalt at 60 lbs/sq
Slag To be installed in aflood coat of 300 lbs/sq N/A Generic
approved asphalt at 60 lbs/sq
MfAMI•DAbE COUNTY
NOA No.: 13-1217.01
Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 8 of 33
EVIDENCE SUBMITTED:
Test Agency Test Name/Report Report No. Date
Factory Mutual Research 4470 2W7A7.AM 08.04.94
Corporation 4450 2D5A9.AM 06.22.99
4470 3001334 02.15.00
4470 3000857 01.I2.00
4470 3004091 01,12.00
4470 3012321 07.29.07
4450 3014751 08.27.03
4450 3019317 06.30.04
4470 3014692 08.05.03
Trinity,ERD TAS 114 11752.09.99-1 02.08.00
TAS 114 02764.09.05 09.09.05
TAS 114 02762.03.05 03.30.05
TAS 117(B)-ASTM D903 020841.06.04 06.02.04
TAS 114 P1734.07.06-R1 02.27.07
TAS 114 P1.738.02.07 02.05.07
TAS 114 P1739,01.07 01.23.07
TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07
ASTM D6164/ASTM D6222 P10490.08.08 08.13.08
ASTM D6164/ASTM D6222 P10490.10.08-RI 10.03.08
ASTM D6222 P7400.03.08-R2 10.09.08
TAS 114(D)—ASTM DI 876 P10070.10.08 10.09.08
ASTM D6222 P10490.10.08-2 10.30.08
FM 4470&TAS 114 P33970.03.1 1 03.15.11
ASTM D6163/ASTM D 4601 P33960.03.11 03.15.11
TAS 114&TAS 117(B) 11757.12.00-1-R1 04.29.13
TAS 114&TAS 1 17(B) 11757.04.01-1-RI 04.30.13
ASTM D6164 P37590.07.13-1 07.02.13
ASTM D6164 P37590.03,13-3A 03.06.13
ASTM D6163 P37590.03.13-2-R1 02.05.13
ASTM D6222 P37590.09.13 09.12.13
ASTM D4601 /TAS 117 P45940.09.13 09,04.13
TAS 114&FM 4474 P41630.08.13 08.06.13
TAS 114(H) P13760.09.09 09.10.09
ASTM D4601 /TAS 117 P45970.05.14 05.12.14
PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08
Technologies
ASTM D6222 PUSA-062-02-02 12.04.08
ASTM D6163 PUSA-064-02-02 02.27.08
ASTM D6694 PUSA-1 34-02-01 05.16.14
ASTM D6694 PUSA-135-02-01 05.16.14
MIAMI•DADECOUNTY NOA No.: 13-1217.01
"'' — Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 9 of 33
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: 1962" or greater plywood or wood plank.
System Type E(1): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved
and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building
Code requirements and are field fabricated utilizing the approved membranes listed in Table 1.
Base Sheet: One ply of Elastobase,XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the
deck as described below:
Fastening#1: Attach base sheet using I I ga.annular ring shank nails and 1-5/8"diameter tin caps spaced 8"
o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet.
Fastening#2: Attach base sheet using OMG 914 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast
#14 with Dekfast Galvalume Steel Hex Plates,Polygrip Fasteners#14 with Polygrip Hex
Plates or Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates spaced 12"o.c. in a
4" lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet.
PIy Sheet: One or more plies of Elastoflex SA V(1.5-mm),Elastoflex SA V PLUS,XtraFlex SBS Base
SA,Elastoflex SA V FR(1.5-mm)or Elastoflex SA V PLUS FR,self-adhered.
Membrane: One ply of Polyfresko G SBS SA,Polyfresko G SBS SA FR,Polyfresko G APP SA,
Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex
SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP G SA,self-
adhered.
Or
One ply of Polyflex G,torch-applied.
Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure: -52.5 psf,(See General limitation#7.).
MuuHi-aAoe courmr
NOA No.: 13-1217.01
Expiration Date: 10/11/17
Approval Date: 11/06/14
Page 26 of 33
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the
top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using
spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8" ribbons in three rows,one
at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq:
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 IV., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below
275 lb£ insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required,as determined by the Building Official,a revised fastener
spacing,prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA,General Limitation 99 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e.perimeters,extended corners and corners).(When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products Iisted herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMI•t)ADECOfjNTy OA No.: 13-1217.01.
•mo Expiration Date: 10/11/17
Approval Date:11/06/14
Page 33 of 33
POLYGLASS USA INC R14571
150 LYON DR
FERNLEY,NV 84408 USA
SINGLE PLY MEMBRANE SYSTEMS
Class A-Fully Adhered
Deck:C-I5/32 Incline:2
I
tion(Optional):--Polyisocyanurate,perlite,wood fiber or palyisocyanuratefperlite board,any
thickness.
Barrier Board:-- in.(min)G-P Gypsum DensDeckO?mechanically fastened with all joints
staggered 6 in.from the p ' d joints.
Base Sheet:—"ELASTOBASE" sand),mechanically fastened or"ELASTOFLEX SA V PLUS
FR","ELASTOFLEX SA V FR"or"ELA LEX SA V FR BASE VENT"(self adhered).
Ply Sheet(Optional),—"ELASTOFLEX SAV R","ELASTOFLEX SA V FR"or
"ELASTOFLEX SA V FR BASE VENT",(self adhered).
Membrane:---"POLYFLEX SA P FR"_ "POLYFRESKO APP SA " "ELASTOFLFX SA P FR",
"POLYFRESKO SB S SA P FR", "ELAS T OFLEX SAV FR HT",(self adher r"POLYFLEX G
FR", "POLYFRESKO TORCH FR","DiUFLEX G FR","ELASTOFLEX S6 G FR>', R]~SICO
MOP FR "ELASTOPLEX VG FR"or"BLASTOSHIELD TS GFR",heat fused
22.Deck:C-15/32 Incii;ne: 1/2
Insulation(Optional):—Poly isocyanurate 1.5 in.(min.)with all joints staggered 6-in.(min.)from the
plywood joints,
Base Sheet:---Ty)e G2,mechanically fastened followed by"ELASTOBASE" mechanically fastened.
Ply Sheet(Optional):—"ELASTOFLEX SAV PLUS - "ELASTOFLEX SA V FR"or
"ELASTOFLEX SA V FR BASE VENT ',(self adhered)
Membrane:---"POLYFLEX SA P FR","POLYFRESKO APP SA P FR", "ELASTOFLEX SAP FR",
"POLYFRESKO SBS_SAP FR",or"DUFLEX G FR","POLYFLEX G FR","ELASTOFLEX S6 G
FR", "POLYFRESKO MOPFRI', "ELASTOFLEX VG FR"or"ELASTOSHIELD TS G FR",heat
fused.
®2012 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products
so identified have been manufactured under UL's Follow-Up Service.Only those products bearing the
UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look
for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to
the following conditions: 1.The Guide Information,Designs and/or Listings(files)must be presented in
their entirety and in a non-misleading manner,without any manipulation of the data(or drawings).2.
The statement"Reprinted from the Online Certifications Directory with permission from UL"must
appear adjacent to the extracted material.In addition,the reprinted material must include a copyright
notice in the following format:"®2012 UL LLC"_