RF-15-2800 Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-247849 Permit Number: RF-11-15-2800
Scheduled Inspection Date: November 18,2015 Permit Type: Roof
Inspector: Rodriguez,Jorge Inspection Type: Final Roof
Owner: BARBARA MARTINEZ, RANDALL CULP Work Classification: Repair Roof
Job Address: 151 NW 92 Street
Miami Shores, FL 33138- Phone Number (305)343-1643
Parcel Number 1131010331020
Project: <NONE>
Contractor: T&S ROOFING SYSTEMS INC. Phone: 305/265-2654
Building Department Comments
TILE ROOF REPAIR Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-247652. CREATED AS
REINSPECTION FOR INSP-247592. CREATED AS REINSPECTION FOR
INSP-247148. No ladder/permit at front
Beware of dog sign at gate
❑Failed Missing uplift test
jeremy 305-928-0124
Correction ❑
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
November 17,2015 For Inspections please call: (305)762-4949 Page 19 of 33
t kACB2 Engineering Inc.
Testing & Engineering Services
Certificatiorrof Authorization#8131 Roof Tile Uplift Test Report
Tel: 954-245.8976; Fax: 954.301.7776
5230 NE 18 Avenue
Fort Lauderdale, FL 33334
Attention: Miami Shores Village, Building Division,
d
10050 NE 2 nAvenue, Miami Shores, FL 33138
Client: T & S Roofing Systems,stems, Inc
Test Date: 11/12/2015 Permit# RF-11-15-2800
Property Address: Culp Residence
151 NW 92 Street,Miami Shores, FI
Roof Pitch: Type of Tile: Roof Area:
3 in 12 Santa Fe Roof Tile 1.20 squares
Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160
Field Instrument : IMADA Force Gauge 0-100 Serial number:243454
Test Location Total Number of Tests Field Uplift Pull Test Test results
Perimeter Area: n/a n/a As per FBC 2014 Passed
Field Area: 1.20 2 As per FBC 2014 Passed
No.of Corner: n/a n/a As per FBC 2014 Passed
Ridge Areas: n/a n/a As per FBC 2014 Passed
Important:
These laboratory results can change due to future weather impacts and/or unavoidable roof
traffic.Therefore,this report represents the TAS 106 results at the time of the test.
Please see attached a Roof Sketch for this project.
CordiallOini
ACB2 EInc. NOA 09-1005.01t )Antonio PE
Fla. Reg6
i
t
ACB2 Engineering Inc.
Engineering and Laboratory Services
5230 NE 18`h Avenue
Fort Lauderdale; Florida 33334
Phone: (954) 245-8976 Fax: (954) 301-7776
"( T
fli
{
Miami Shores Village
Building Department
10050 N.E.2nd Avenue,Miami Shores,Florida 33138 $v?0V G i
Tei:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949
FBC 201 q 11
BUILDING Master Permit No. Fy 9co
PERMIT APPLICATION Sub Permit No.
(BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
[]PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS E CHANGE OF ❑CANCELLATION SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS:
City: Miami Shores County: Miami Dade Zip: I ,
Folio/Parcel#: Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
n '-7
-r
.,���' � �-��v"� one#.
OWNER:Name(Fee Simple Titleholder ���•, ����"� ��yr�r�' '' "f °��a �- a�
� � x
Address d
City: j' 1� �C`�'C State: s! Zip: _.� 4S (� )
Tenant/Lessee Name: AJ /'�. Phone#:
Email: °� i(d a � Vlj1 j j'j VY)
i
CONTRACTOR:Company Name: _ '��' � '��� ' , Phone#: rs— uJ"��6�
Address:
City: I State: Zip:
Qualifier Name: � ^ Phone#:
State Certification or Registration#: L{� V' Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ Square/Linear Footage of Work: 12(1
Type of Work: ❑ Addition ❑ AI eration New / F-1 Repair/Replace ❑ Demolition
Description of Work: I "O '�✓
Specify color of color thru tile:
Submittal Fee$ t _Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$
(Revised02/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address -
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
�
Application
is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
Appl y
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
= Signature
OWNER or AGENT CONTRACTOR
V
a oregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
N day of 111i0NIJ 20 by day of �� 20 , by ,-
Q�0. \ *
� , who is personally known to who is personally known to
UJ
r who has produced as me or who has produced as
�W�
ids ification and who did take an oath. identification and who did take an oath.
�vo�
"R
NOTARY PUBLIC: a m
RY PUBLIC: o cn Cn
31�-*�
C�-Tnm
' Sign: m N
Print:
Print: 3
Seal: Seal:
r ` � Zoning
APPROVED BY Pians Examiner g
Structural Review Clerk
(Revised02/24/2014)
Y
MIAMI•DADE Miami-Dade County HVHZ Electronic Roof Permit Form
EM
"Deliverin Excellence Every Day"
Section A (General Information)
Master Permit No: Process No:
Contractor's Name: T AND S ROOFING
Job Address: 151 NW 92 ST
Roof Category
0 Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adh r.�v Set Tile
600660
.. C$
❑ Asphaltic Shingles ❑ Metal Panel/Shingles Weod ShiijPg/Shakes •,
❑ Sprayed Polyurethane Foam ❑
Other: •"•••
Roof Type ���• �•�• ••�••
❑ New Roof ❑ Re-Roofing ❑ Recovering ❑✓ Repair •• •• •• •• ••
❑ Maintenjr ,•
Are there Gas Vent Stacks located on the roof? ❑ Yes 0 No If yes, what typg Q NatLiat• LPG*• •
Roof System Information •.. ••• : •
Low slope roof area (ft.2) 0 Steep Sloped area (ft.2) 120 _ Total (ft.Z) 120 •
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Perimeter Width (a'): Corner Size (a' x a'):
Now ON-MmF
FF a
`3
ftk
7
0
�'A r n
i
MIAMhD,ADE
Miami-Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence every Day"
Roof System Manufacturer: SANTA FE TILE CORP
Notice of Acceptance Number(NOA): 12-0210.01
Minimum Design Wind Pressures, If Applicable(from RAS 127 or Calculations):
P1: 39.1 P2: 8.1 P3: 100.7
Maximum Design Wind Pressures, (From the NOA Specific system): 61 9 psf
6 . 666666
Fill in the specific roof assembly components. if a component is not required, insert not applicable i'nIaj in th§jVXC j ox- •
Deck Type: -- Select Dgr•ll;Type -- ... •
6000 +.... .....
666666 . • 66666
Optional Insulation: •••• •.w'w; .ww...
666666
Optional Nailable Substrate?• • .• ;'; '
Optional Nailable Substrate Attachment:
Roof Slope: 3 "/12"
Roof Mean Height: 15 ft. Basesheet Type:
Method of Tile Attachment: 11.30 ASTM TYPE II
--Adhesive, Medium Paddy Polyfoam Polypro-Lj Type for Basesheet Attachment:
Alternate Method of Tile Attachment per NOA: 1 1/4 RS NAILS 6" OC AND 12" FIELD
Tile Underlayment(Cap Sheet)Type:
ILE SEAL
Drip Edge Size&Gauge: --3"face 24 ga.--
IT
Tile Underlayment Attachment Method:
Drip Edge Material Type: I--Galvinized Metal- SELF ADHERED
Drip Edge Fastener Type: 1 1/4 RS NAILS Tile Profile:
SPANISH S
Hook Strip/Cleat gauge or weight: -- Select Hook Strip
i
i
MIAMI-D DE Miami-Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every tray"
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are
greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable.
P 1: 39 1 x x .297 = 11.61 -Mg: 5.82 =Mr1: 5.79 < 61.9 NOA Mf
P 2: 68.1 x .297 = 20.22 -Mg: 5.82 =Mr2: 14.4 < 61.9 11 NOA Mf
P 3: 100.7 x X .297 = 29.90 -Mg: 5.82 =Mr3: 24.08 61.9 NOA Mf
Method 3 "Uplift Based Tile Calculations Per RAS 127"
or Uplift based tile systems use Method 3.Compare the values for F'with the values for Fr. If the F'values are greater than or equal to the Fr values,for
!ach area of the roof,then the the attachment method is acceptable.
'1: x I: = X w: _ -W: x cos 0: =Fr1: <_ NOA F'
32: X l: = X w: = -W: = X cos 0:El=Fr2: < NOA F'
'3: X I: _ Xw: -W: = X cos 0: =Fr3: _< NOA F'
_ '
Where to Obtain Information to complete tile calculations
Where to Find•..• • •
Description Symbol ......
Design Pressure P1 or P2 or P3 Table 1 RAS 127,or by an engineer analysis prepared,sigr�e�c�and seal,d by a profec eioha e
engineer based on ASCE 7,
Mean Roof Height H Job Site ••;••; •• •• ••
Roof Slope 0 Job Site •..... . .'
Aerodynamic Multiplier Product Approval(NOA),, ;•••••
Restoring Moment due to Gravity Mg Product Approval(NOA) .• :•: ' '
Attachment Resistance Mf Product Approval(NOA)
Required Moment Resistance Mr Calculated
Minimum Attachment Resistance F' Product Approval(NOA)
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval(NOA)
=length
Tile Dimensions w=width Product Approval(NOA)
IAMI-
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miainidade.gov/l)era
Santafe Tile Corporation
8825 NW 95"' Street
Medley,FL 33178
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
.000.0
RENEWAL of this NOA shall be considered after a renewal application has been filed ark there has Deen no change 0
in the applicable building code negatively affecting the performance of this product. """ •
0000.. 0000..
000.0.
0000..
TERMINATION of this NOA will occur after the expiration date or if there has been a r0?§161a or cIWftVe0 the• •
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of anprodut':"
.
, 0yt'0for sales, advertisingor an other purposes shall automaticallyterminate this NOA. Failureta.G,dp1Y%4h�Y sec14l
..
of this NOA shall be cause for termination and removal of NOA. :00:0: 0 •
0 0 0 0 000000
0 00.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Floti'tla, and'fo0llo.wed by,M;
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, they i�shall be'done 0
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This replaces NOA# 10-1005.15 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0210.01
MIAMI-DiADE COUN rr Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Clay
Deck Type: Wood
1. SCOPE
This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile,as manufactured by Ladrillera
Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
AAgplicant Dimensions Specifications Description
Santaf6 `S' Clay Roof L= 18" TAS 112 One piece high profile clay roof tile equipped with
Tile W= 11.1" two nail holes. For nail-on, mortar set and adhesive
set applications.
Trim Pieces 1=varies TAS 112 Accessory trim, clay roof pieces for use at hips,
w=varies rakes, ridges and valley terminations. Manufactured
varying thickness for each tile profile.
2.1 MANUFACTURING LOCATION
1. Bogota, Colombia
2.2 SUBMITTED EVIDENCE ••••••
Test Agency Test Identifier Test Name/L a"i "'Date.•.. •
The Center for Applied Engineering, Inc. 94-156-8 TAS 1Qf"" 'Aug. 1994...:
94-156-9 TAS 102,,,• •����•
The Center for Applied Engineering, Inc. 25-7205-1 TAS 10r:••; VIrch 1995••
The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100.... Sept. 1994 ••
(307023) ......
Redland Technologies 7161-03 TAS 10$ �I��c. 19;4•••
Appendix I1 (Nail-On)
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102 &TAS 102(A)
Redland Technologies P 0402 Withdrawal Resistance Sept. 1993
Testing of Screw vs smooth
shank nails
NOA No.: 12-0210.01
MIAMI•DADE COUNTY
Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 2 of 5
2.2 SUBMITTED EVIDENCE
Test Agency Test Identifier Test Name/Report Date
Redland Technologies P 0647-01 TAS 108 Aug. 1994
(Mortar Set)
Redland Technologies P 0631-01 PA 108 July. 1994
(Mortar Set)
Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999
IBA Consultants,Inc. 2353-4 Restoring Moment Aug. 1999
PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02
IBA Consultants,Inc. 2353-70 TAS 101 09/22/03
IBA Consultants, Inc. 2353-71 TAS 101 09/22/03
IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code. :...:.
3.7 May be installed on slopes 7:12 and greater. •
...:..
4. INSTALLATION ••••••
. .... .... . .
4.1 Santafe 'S' and its components shall be installed in strict compliance with R!oo&41 Applicakon Standard.
RAS 118 RAS 119 and RAS 120. •••••• • • •••••
.. .. .. .. ......
4.2 Data For Attachment Calculations .
Table 1: Average Weight (W) and Dimensions (I x w
. . ..
Tile Profile Weight-W (lbf) Length-1 (ft) W crtgw A
Santafe `S' 6.7 1.5 0.958
NOA No.: 12-0210.01
MIAMI•DADE COUNTY
Expiration Date: 02/01./16
Approval Date: 05/31/12
Page 3 of 5
Table 2: Aerodynamic Multiplyers—X(ft)
Tile ), (ft) X (ft)
Profile Batten Application Direct Deck
Santafe 'S' 0.274 0.297
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile 2":12" 3":12" 4":12" 5":12" 6":12" - 7":12" or
Profile greater
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Deck Deck Deck Deck Deck Deck
Santafe 'S' 5.93 5.90 5.85 5.82 5.73 5.69 5.56 5.53 5.32 5.29 5.03 5.00
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Nail-On Systems
Tile Profile Fastener Type Direct Deck Battens
Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A
One#8 Screw 29.16 N/A
Two#8 Screws 38.28 N/A
One#8 Screw w/Clip 57.31"2 N/A
Two#8 Screws w/Clip 57.60 61.77
1. Approved screws as noted'Product manufactured by others'.
2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Santafe 'S' Tile Bond 38.9
Polyfoam Polypro AH 160TM •
2 See manufactures component approval for installation requirements. • • ••••+
3 Flexible Product, Inc.Average weight per patty 10.4 grams. •• • • •
4 Polyfoam Product, Inc.Average weight per patty 9.4 grams. '••"• •••••
Table 5A: Attachment Resistance Expressed as a Moment -F&.(ftjlbf) ' ••••
for Single Patty Adhesive Set Systems ••.�.. ..:..
Tile Tile Application •• ijnimum tad men
Profile R,"es'sta ce •
Santafe 'S' Polyfoam Polypro,AH 160TM (Mil••
Pol oam Polypro AH 160TIl 00 61.9... ;•••'
5 Paddy placement of 63 grams of Polypro AH 160TM.
6
Paddy placement of 24 grams of Polypro AH 160 TM.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mortar or Adhesive Set Systems
Tile Tile Attachment
Profile Application Resistance
Santafe 'S' Mortar Set 23.6
NOA No.: 12-0210.01
MIAMI-DADE COUNTY Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 4 of 5
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami-Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH"S"CLAY ROOF TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWING
When using one screw
use this hole.
18"
O
•
•
•••••• • • •••••
11.1" .. .. .. .. ......
. . . . ......
•
"SANTAFE S" CLAY ROOF TILE
END OF THIS ACCEPTANCE
o.:
MIAMt•DADE couN7Y NOA N 12-0210.01
■11111611 '''.0 ■ Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 5 of 5
MAW MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
ME 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE NOA www.miamidade.gov/economy
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN. 55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTM 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has beerf i.fe,ision pr c)lange in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endomement of any produc ,.W..
sales, advertising or any other purposes shall automatically terminate this NOA. Failure t6vc;mply with any sectien of
this NOA shall be cause for termination and removal of NOA. 0"" "•• •
.... .... .....
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, 11er•.i a, and T.6.14o.w. ed bY*.h..e.•
.
expiration date may be displayed in advertising literature. If any portion of the NOA is dispjayAd, then itshall be dory'
in its entirety. 0 '
. . ......
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufadthref or it$*di$tYtbutors and •
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0502.02 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0805.01
MIAMI•DADE COUNTY
C• ' , Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by
applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using 2-Component
Foam Roof Tile Adhesive AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component N/A TAS 101 Two component polyurethane foam adhesive
Foam Roof Tile Adhesive
AH-160
Foam Dispenser N/A Dispensing Equipment
RTF1000
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof the adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES: •
. ...... . ......
Property Test Resins.
......
Density ASTM D 1622 1.6 lbs./ft.3 .••••• •
Compressive Strength ASTM D 1621 18 PSI Parallel to rise •• 6666 66:600
..... .....
12 PSI Perpendicular to roe. • •0 0••0 0*•0:•
Tensile Strength ASTM D 1623 28 PSI Parallel to rise �,.... •
Water Absorption ASTM D 2127 0.08 Lbs./Ft2 .
......
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch •
Dimensional Stability ASTM D 2126 +0.07%Volume Change g!40'F., 2 oet •
+6.0%Volume Change @ 15 8°F., 100°l*Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 14-0805.01
MIAMI•DAD,COUNTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 2 of 11
EVIDENCE SUBMITTED:
Test Auency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[1] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 .03/Q2/99
520109-2-1 00600
•• • • • •
•666•• •
LIMITATIONS: 666.6• 6 6.66••
600.00 6
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assgrmb}y for firg*favirig. 0 •
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat aLlv.,&high 01e pGofles..;..'
3. Minimum underlayment shall be in compliance with the Roofing Application Standard ISMS 120. " -6 ...
6.6600 • 6
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 27Component Foant Roof6Tile Adhesive AH-*6•:
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 10 t. :*000*
..•.:
5. All products listed herein shall have a quality assurance audit in accordance with the Florida BuijdPhg Code and
Rule 61G20-3 of the Florida Administrative Code.
=NTNOA No.: 14-0805.01
MIAMI•DE CExpiration Date: 05/10/17
Approval Date: 09/04/14
Page 3 of 11
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County
Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0
(B)•
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or
ProPack® 30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
.
•9069
. . . . ......
66.9 69�• • •
9.9• •969 ••6••
•• •• •• •• •999••
96.9.6 6 6
•
•6••99
• • • ••999•
NOA No.: 14-0805.01
MIAMMMADE COUNTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 4 of 11
i
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq. inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel (Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
MIAMI•DADE COU
BUILDING PERMIT REQUIREMENTS: •
As required by the Building Official or applicable building code in order to properly evaluatt tliglustallation of this ••••••
.• • • •
System. •••••• �••••• ••••�a
•
•• •• •• •• ••••••
•
NOA No.: 14-0805.01
MIAMI-DADE COUNTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 5 of 11
l
ADHESIVE PLACEMENT DETAIL# 1
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm)x 10"(254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
" xo In, of the tile being set.
"�Mt4ns ovilail
2. Continue in same manner. Insure approximately 17
w (109.7 cmc)—23 (148.4 cm) square inch adhesive
contact with the underside of the tile.
2/6 �_ 0"
EAWAf Cit. �
Nall ihm h viawkc•me Medium Profile! Double Pan Tile
1when requiretm
N 1. Starting at the eave course, apply a minimum 2"
4
(50.8 mm)x 10" (254 mm)x 1"(25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
�Y. overlock of the tile being set.
z
2. Continue in same manner. Insure approximately 17
a�irri
(109.7 cm2)—23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
L�mrw m ..'
.� Fascia
NA Rio plar9ie High Profile/Single Pan Ta14.. ••'• •
(wikiarr # r M CeS4•lFRi $itti' • ••••••
1. Starting at the eave co>. a-apply a lmrnimum 21••••
(50.8 mm)x 10" (254 mhi7 k 1" (25.trMt ) foam';•••
Y' paddy onto the underlayment.positioned as shoW
tom �,•,: under the pan portion of�t1�•tjle closest to the �•
overlock of the tile beilg s2t: 411 ••••;•
' 2. Continue in same manner. Insure approxi-mately�'� •
yam•,.
(109.7 cm)—23 (148.4 cm) squareihehadhesive
> b contact with the underside of the tile.
Yom`
NOA No.: 1.4-0805.01
MIAMI-DAD,COUNTY Expiration Date: 05/10/17
®, Approval Date: 09/04/14
Page 6 of 11
ADHESIVE PLACEMENT DETAIL# 2
mit tlhmogh p4ok 4#M004 , y 1 **f%rel Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm)x 10" (254 mm)x 1" (25A mm) foam paddy
". onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
' i" the tile being set. Insure approximately 17 (109.7 cm2)
k
—23 (148.4 cm2) square inch adhesive contact with the
Wrc underside of the tile.
Eaur ,.
' 2. At the second course, apply a minimum 2"(50.8mm)
''' �o Ira:'•-,� w � °`� '�'�.� „� x 7 (177.8 mm)x 1 (25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the the
P x being set.
3. Continue in same manner. Insure approximately 10
(64.5 cm2) - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Ie � 1� •s�1 ,9 Medium Profile/Double Pan Tile
ilwben requiredl
Paddy t11anoa ttilt) 1. Starting at the eave course, apply a minimum 2" (50.8
mm)x 10" (254 mm)x 1" (25.4 mm) foam paddy
ry ._ onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm )—
� 21&. 23 (148.4 cm) square inch adhesive contact with the
underside of the tile.
Wrttt 5epee � _ �r • • �••••• 9999••
2. At the second course, apply It m1nimuol 2; 0.8mm)
„ „ • ••• • • •••
,� x 7 (177.8 mm) x 1 (25 mmj foam paddy onto the �
f underlayment positioned a�jl�gwn undo she pan ••••
portion of the the closest to.Or.averlotLQtthe tiles••••
�.� Ferri
being set. 99:00: 0 00:06
•• •• •• •• 9099•0
3. Continue in same manner;IiZM approxifnately 12"
(77.4 cm2) - 14(90.3 cm2 square incl adhesive .
contact with the underside p14;tile. ••••••
(Instructions continued on next page)
NOA No.: 14-0805.01
MIAMI•DADE COUNTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 7 of 11
ADHESIVE PLACEMENT DETAIL# 2 (CONTINUED)
glwough p6nk High Profile/Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
� .. mm)x 10"(254 mm)x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
9 tile being set. Insure approximately 17 (109.7 cm )—
o . 23 (148.4 cm ) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
"Fascia x 7" (177.8 mm)x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
blip"� portion of the tile closest to the overlock of the tile
* being set.
3. Continue in same manner.Insure approximately 17"
(109.7 cm2) - 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
•6••6•
I
• • • 0000••
• 0000•• •
•60••• • •000••
0000•0 • 0 0
00600000 :0000:
0000 0000 •••9•
• •
•••66• • • 0000•
• • 0 • 9
•• •• •• •• •••66•
•
•••6•• • •
• • • • 0960••
0000••
• • •
® NOA No.: 1.4-0805.01
MIAMI-DADE COUNTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 8 of 11
ADHESIVE PLACEMENT DETAIL#3
mad threu ptasticcaement Pad (between tiles)
iwten requiredl 1. On the eave course only, apply a minimum 2" (50.8
Battens optiona • � mm)x 10" (254 mm)x 1" (25.4 mm) foam paddy
pad tundwmile) onto the underlayment positioned as shown,under
anuf V d the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
ain.
+� to the Overlock of the tile being set. Leave
approximately 4" (101.6 mm)up from the eave
singii:pde�t * H. edge free of foam to prevent the expanded adhesive
$
• from blocking the weep holes. Insure
approximately 17-23 int (109.7-148.4 cm2) of
adhesive contact with the underside of the tile
in.
2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4
mm) foam paddy onto the underlayment just below
FlaVLawPrttlll@TUe the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
RaillWou0piasUcceinent Single paddyunietde pan portion of the tile, closest to the underlock for
then re"Fredl
the second course the to be installed. Insure
approximately 8-9 int (51.6-58.1 cm2)of adhesive
Battens PaAdy(andertilo contact with the underside of the tile.
optimal
Single
onto (Instructions continued on nextpage)
x a in.
add or. A �. �
t0 in, tin. �
Erm Game
• • • •
riP1f,@ Course •• • • • •
Medium P?roffieTil •••••• • • •
•••• •••• •••••
•••••• • • •••••
•
• • • • ••••••
NOA No.: 14-0805.01
MIAMI-DAD«Co'NTY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 9 of 11
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
Nail through plastic 54 epaddy elide
(when requireib 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x /4"
paddy4 b at weea dks) (19 mm)paddy on top of the eave course tile
Battemm surface as shown, on top of the strengthening rib
Optional PacWylunderflief
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
.arn. 9 (5 8.1 cm2) - 11 (71cm ) square inch adhesive
x4 in. ��, contact with the underside of the tile at the overlap
paan and 7 (45.2 cm2)-9 (58.1 cm2) square inch
m ° adhesive contact with the underside of the tile at
x the head of the tile. Continue in same manner.
Ea se C•rarse 'I"asda
W"Phate
win. In. Ewe dosure
Odp edge
H112t►Presale Taw.
•
t •
•
®®I NOA No.: 14-0805.01
MIAMMADE COUNTY
Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan) Tile
i 1 plate enough adhesive to achieve 05 to 70sq in 1. Starting at the eave course,apply a minimum 2"
Steep pitch applications
in contest whir the pan tile. (when required) (50.8 mm) x 10" (254 mm)x 1" (25.4 mm) foam
21 Turn covers upside down.Place adhesive In paddy onto the underlayment positioned as
to t In.from outside edge ofcover tile. shown under two adjacent pan tiles. Support eave
Then install the tile.Ensure 20 to
25 sq,in,contact area. a« tiles from rocking until adhesive has a chance to
Underlagment � �
cure.
« 2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
:. approximately 65 (419.4 cm2)—70 (451.6 cm2)
�5 square inch adhesive contact with the underside
c Sheathing
of the pan tile.
Eaveclosure
(motarshown) 3. Turn covers upside down exposing the underside
Weephole '�FaxciBoardof the tile. Apply a minimum 1" (25.4 mm)x 10"
a ,-�°'`
(254 mm) bead of adhesive directly on the inner
Remove top portion of the eave course cover tile,Abut to second course of edge of each side of the cover tile. Leave
pan tiles.Ensure eave end of pan and cover tiles are flush at eave line.
approximately 3/4„ (19 mm) to 1„ (25.4 mm)
Two Piece Barrel-Nigh Profile Tile from the outside edge of the tile, inward, free of
foam to allow for expansion. 9 9
0000..
.066.9
4. Turn cover tile over aftor foam ij apptied and •
place onto pan tile c8fifW Insure'a minimum df”•
20 (129 cm2) -25 (1 t1 em2) squ00are inch ••••
009 00
contact area on each%'a:�f the L%vgr tfle to 1 A..
pan tile. Continue in w"Q manner: Trim awaiyi,:..•
any cured exposed fesir dhesiver Pointing o6••••
longitudinal edges of the tpver tiles are •,
considered optional.' 0 :000:0 0'•0'
.. . . 0000..
5. When additional nailing is requifeA 2;(50.86 •
mm)x 4”(101.6 mm)nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 14-0805.01
MIAMI-DAoe eounirY Expiration Date: 05/10/17
Approval Date: 09/04/14
Page 11 of 11
MIAMI•DADE
� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing LLC.
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. •
. • •
DESCRIPTION: BORAL TileSeal ......
'
•
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,gity,state followitp
statement: "Miami-Dade County Product Control Approved",unless otherwise noted hereine••• •••• #0000
RENEWAL of this NOA shall be considered after a renewal application has been filed Ad t1ler�e has been no change i s•
in the applicable building code negatively affecting the performance of this product. ,.•.:,
TERMINATION of this NOA will occur after the expiration date or if there has been a rev wios or chance�n the •
•
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of My 11roduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#12-1219.01 and consists of pages 1 through 4.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 13-1113.05
MIAMIMADE COUNTY
... Expiration Date: 07/31/17
E � P
Approval Date: 03/13/14
Page l of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
BORAL TileSeal 36"x 36'rolls TAS 103 SBS self-adhering asphalt sheet material with a
36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
MANUFACTURING LOCATION:
1. Brentwood,NH
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,Inc. R14610 Follow up Service 03/28/02
IRT-Arcon, Inc. 02-012 TAS 103 02/28/02
PRI Asphalt Technologies, Inc. NEI-006-02-01 TAS 103 04/01/02
PRI Asphalt Technologies, Inc. NEI-008-02-01 TAS 114 (H) 07/30/02
PRI Construction Materials NEI-045-02-01 ASTM D 4798 &ASTM G 155 08/08/07
Technologies, LLC. NEI-053-02-01 ASTM D 4798 &ASTM G 155 05/01/08
NEI-076-02-01 TAS 103 /ASTM D4798 02/14/11
NEI-034-02-02 ASTM D 1970 01/29/13
0000..
• 0000..
0000.. •
0000.. 0000..
0000.. •
0000..
0000 0000 •
0000 0000 06.00
666660 0 . 0000.
. . . 0
..... .. .. 0000..
666666 6
' 0000.. i
.66666
0 . 666666
. .. . . ... . .
66 0
-� NOA No.: 13-1113.05
MIAMI•DAD15COUNTY Expiration Date: 07/31/17
Approval Date: 03/13/14
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 15/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck,membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"head lap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum
6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps
without black selvage area shall be sealed under lap using an SBS modified mastic.
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps.
No nails or tin caps shall be exposed.
Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened Roof Tile,
Metal Roofing, Wood Shake& Shingles, and Asphaltic Shingle assemblies.
• II
0000..
0000..
0000•• •
000000 0 4
0000.. 146000
0000..
000• 000•
0 0 0
0000 :000 00.00
0000..
60 0 0 0000.
•
00 00 .. 4*0 •*0606*••
:09:0:
• 0 • • 000000
6060••••
• 60 0 0 •
• 0 0 •4000•
00 0 0 4600 • •
0 •
NOA No.: 13-1113.05
MIAMI•DADE COUNTY
...� � Expiration Date: 07!31/17
Approval Date: 03/13/14
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL
TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami-Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products,wind uplift resistance, and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6 piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORATs TileSe*al underlayhMed;-
shall be applied over the underlayment, and sealed using an SBS modified mastic. •• •
15. All products listed herein shall have a quality assurance audit in accordance with th;o,00 da Buildipg Code.and•.
Rule 61G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manui� at'tQrer's na"e*br logo,*NP
... 1.
and state of manufacturing facility, and the following statement: "Miami-Dade Count P'roatct Cox%rol XpproyjV.' .•
or the Miami-Dade County Product Control Seal as shown below
MIAMI•DADE COUNTY ' ` i.•.i• ""'
END OF THIS ACCEPTANCE
NOA No.: 13-1.113.05
CMIAMIRMeOUNTY Expiration Date: -1113.05� 07/31/17
Approval Date: 03/13/14
Page 4 of 4
RE
\ � €�
\ Perrnt
Miami Shores Village
10050 N.E.2nd Avenue NW "Ah wo'd 'd 1r Rol f 3
Miami Shores,FL 33138-0000
Phone: (305)795 2204
CORLp�' v,. A vw
Expiration: /01/2016
14
1
Project Address Parcel Number Applicant
151 NW 92 Street � � 1131010331020 �� �®
Miami Shores, FL 33138- Block: Lot: RANDALL CULP BARBARA MAF
Owner Information Address Phone Cell
[�RRA�ND:AL:LICULP BARBARA MARTINEZ 151 NW 92 Street (305)343-1643
MIAMI SHORES FL 33150-
151 NW 92 Street
MIAMI SHORES FL 33150-
Contractor(s) Phone Cell Phone Valuation: $ 1,500.00
T&S ROOFING SYSTEMS INC 305/265-2654 Total Sq Feet: 120
i
Type of Work:Repair Available Inspections:
Additional Info:TILE ROOF REPAIR
Inspection Type:
Classification:Residential
Roof Repair
Scanning:3 Final Roof
Review Roof
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $1.20
Invoice# RF-11-15-57647
DBPR Fee $2.00
DCA Fee $2.00 11/03/2015 Credit Card $ 116.20 $0.00
Education Surcharge $0.40
Permit Fee-Repairs $100.00
Scanning Fee $9.00
Technology Fee $1.60
Total: $116.20
In consideration of the i t
issuance o me of thisermit I aperform
p gree to the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I ass u a resp n ibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for RICAL, P MBI G, ECHANICAL,WINDOWS, DOORS,ROOFING and SWIMMING POOL work.
OWNER AFFIDA IT: Ice th tall he f rego/aove-named
rmation is accurate and that all work will be done in compliance with all applicable laws regulating
construc on and z . Fut rm re, I u or hcontractor to do the work stated.
November 03, 2015
ut zed Signature ner / Ap ant / Contractor / Agent Date
Building Depa ent C py
November 03, 2015 1