Loading...
RF-15-2590 Permit Nn. RF-10-16-2690 Miami Shores Village Parrolt Type:Roof S. 10050 N.E.2nd Avenue NW Wo*Plassflycotion:Til er Miami Shores,FL 33138-0000 PetlTft `tattt : tPpRCfilil ham Phone: (305)795-2204 ira F� a RroA tion: 0 190201 s [esus I� 1 t�il�t�'15 Expiration: Project Address Parcel Number Applicant 51 NW 91 Street 1131010000172 ROSE JIMENEZ Miami Shores, FL Block: Lot: Owner Information Address Phone Cell ROSE JIMENEZ 51 NW 91 Street MIAMI SHORES FL 33150-2254 51 NW 91 Street MIAMI SHORES FL 33150-2254 Contractor(s) Phone Cell Phone Valuation: $ 15,000.00 BLUE PANTHER ROOFING&CONSTF (305)807-1058 Total Sq Feet: 2400 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF FOR TILE Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Review Roof Renailing Affidavit Review Building Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-10-15-57403 CCF $9.00 10/22/2015 Cash $792.00 $50.00 DBPR Fee $4.50 DCA Fee $4.50 10/14/2015 Cash $50.00 $0.00 Education Surcharge $3.00 Bond#:2892 Permit Fee-New Roof $300.00 Scanning Fee $9.00 Technology Fee $12.00 Total: $842.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFF AVIAFure, at all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction o iI authorize the above-named contractor to do the work stated. October 22, 2015 A zed re:Owner / Applicant / Contractor / Agent Date Buil ng Department Copy October 22,2015 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-247654 Permit Number: RF-10-15-2590 Scheduled Inspection Date: November 16,2015 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: JIMENEZ, ROSE Work Classification: Tile Job Address:51 NW 91 Street Miami Shores, FL Phone Number Parcel Number 1131010000172 Project: <NONE> Contractor: BLUE PANTHER ROOFING&CONSTRUCTION CORP Phone: (305)807-1058 Building Department Comments RE ROOF FOR TILE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-245575. See prior inspection comment Tile underlayment may not be exposed Missing renailing affidavit Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. November 13,2015 For Inspections please call: (305)762-4949 Page 29 of 40 r � Miami shores Village � ,®o® ww.M Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 IORtDA Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit#_ ( ® I �, q C) DATE: i Z INSPECTION AFFIDAVIT licensed as a (n) Contractor/Engineer/Architect, (Print nam and cirde License Type) FS 468 Building Inspector License#: CCC,- k jjZ- �;c1 �3 On or about 16 1 Lt:5 i T- , I did personally inspect the roof deck nailing (Date 8*w) work at rL� W G k (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) ' n re State of Florida County of Dade: The undersigned, being the first duly swo s and says that he/she is the contractor for the above property '(P a mentioned, PP�oN Ps a e olZ��2p16 M P°dl�c'ite5 p,�9,950g1 0. Sworn to and SC, .' a_y,�mp4#o�lNo�a�y PSS day of z° "' �0�9 y °' 9pQaeaS� i Notary Public, Sat arge 'General,Buil ft Residential,or Roofing Contractors or any individual certified under 468 F.S.to make such an Inspedon.Include photographs of each plane of the roof with Miami Shores Village "� L �� Building Department OCT � 4215 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 5" FBC 2014 ,� BUILDING Master Permit No. i� ' 2S tqy PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC E3�ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL F—IPLUMBING ❑ MECHANICAL PUBLIC WORKS CHANGE OF ❑CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 14 � (�-r City: Miami Shores County: Miami Dade Zip: -A 3 1 Folio/Parcel#: i/I If Ce i 0 r—® 01111 Is the Building Historically Designated:Yes NO Occupancy Type: Load: (({� Constructiioon[Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): ( "1 6' Phone#: Z 0 16 Address: Lb; I&AGoE City: �A d 4e-,a '�' State: Zip: Tenant/Lessee Name: Phone#: Email: p� CONTRACTOR:Company Name: �0� �� ( � �Iti �1 t� , Phone#: 3057 c + ke Address: 1 (,I City: iA I&tA-a Stater Zip: ( � Qualifier Name: State �'� A� Phone* State Certification or Registration M CS—L/ + Ci (o�J Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ r �. ���� � � Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New IT Repair/Replace ❑ Demolition Description of Work: P=L E ��ls Specify color of color thru tile: Submittal Fee$ Permit Fee$. 2CC) ,C�� CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ SC ° SA- TOTAL FEE NOW DUE$ (Revised02/24/2014) 1 Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing Information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature , Signature ONER or AGENT CONTRACTOR The foregoing Instrument /I acknowledged before me this The foregoing instrument was acknowledged before me this day of 20 f by day of 0G�-6 .20 S by who is personal) JL a C- ®«/Ic,;7 .who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identification and who id take an oath. NOTARY PUBLIC: NOTARY P BLIC: ,, j Sign: Sign Print: --rPri ro Seal: �3 4 Uri IP1111 S a IYII s�` g COMMISSION#EE831658 COMMISSION i VA168$ EXPIRES:JSept 3, 2016 ,,; ,iylS�1N WI� `RE6:p Sept �3. 20010 NNNNNNN NNNNNNNNNN+RIiI{I NNNNNNNNNNN +k (ei1Ti{f NNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNN+PNNNNNNNNNWup�RNNfyA 9F�A #'MMaNNN APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) r S 004674 e us ;ness T Roeopt° Miairn�- er�tY State of Flr��a A-SILK - DO NOT PAY . 6490544 �usss.ntaivtE,f oco,Ttcnt RE�t:tPT NO. EXPIRES BLUE PANTHER ROOFING&CONSfRIJ ON CORP�ENEWAL $��'�`� BEES ,�, 20'1 46 ?SSN 1 fiaRR 6i6Q42f3 W4 ire d+ ptaYad at ilaca of liusrness Mihl[l.x,53134 _ Witt GoiiKltY CQcJe- Chap4er 8A Art OWNER, SEC.TYPE OF BUSINESS ppYMENT-RECEIVED BI.IJE PANTHER ROOFING kCONSf 196 SPECIALTY BUILDING COi�iTFIACTOR i3Y TAX COLLECT9� CORP CCC13*6'9 $75.00 Q /12/2015 1tVorker(s) t CREDITCARD-15-p�5642 This'Locallusiness Tak Receipt only.copfirms Payptent of the Local Busiaeis Tex The Receipt is not a Itc@ase, partrti4 ora certification of the bol"rsaliticeti0itstirtealfigsiness to the bermustoAFplywit anti 9�gF+►!n®�I ornoagovammentelregulatorylawsa, requiremerowhichapPiy Tba AEC@IP�N0.abovemust be displayed on all aotmnercial vehicles-Miami_DWv Co&Sec fla-27& For moreintormason,Wait vmwmiamldadej^^glta Mentor ' Date CERTIFICATE OF LIABILITY INSURANCE 10/12/2015 producer. Plymouth Insurance Agency This Certificate Is Issued as a matter of information only and confers no 2739 U.S. Highway 19 N. rights upon the certificate Holder. This Certificate does not amend,extend Holiday, FL 34691 or alter the coverage afforded by the policies below. (727)938-5562 1 Insurers Affording Coverage NAIC# Insured: South East Personnel Leasing, Inc. &Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer B: Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement,term or condition of any contrect or other document with rasped to which this certificate may be issued or may pertain,the insurance afforded by the policies described herein is subject to all the terms,exclusions,and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR ADDL Policy Effective Policy Expiration Limits LTR INSRD Type of Insurance Policy Number Date Date (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence Commercial General Liability Damage to rented premises(EA Claims Made 13 Occur occurrence) Med Exp Personal Adv Injury :neral aggregate limit applies per: Policy ❑Project ❑ LOC General Aggregate Products-Comp/Op Agg AUTOMOBILE LIABILITY Combined single Limit Any Auto (EA Accident) S All Owned Autos Bodily Injury Scheduled Autos (Per Person) Hired Autos Bodily Injury Non-Owned Autos (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrence ROccur ❑Claims Made Aggregate Deductible A Workers Compensiallion and WC 71949 01/01/2015 01/01/2016 X wC Statu- OTH- Employers'Liability I tory Limits ER Any proprietor/partner/executive officer/member E.L.Each Accident $1,000,000 excluded? NO E.L.Disease-Ea Employee $1,00,000 If Yes,describe under special provisions below. E.L.Disease-Policy Limits $1,000,ODD Other Lion Insurance Company is A.M.Best Company rated A-(Excellent). AMB#12616 Descriptions of Operations/Locations/1/ehlcles/Exclusions added by Endorsement(Special Provisions: alert ID: 91.67-745 Coverage only applies to active employee(s)of South East Personnel Leasing,Inc.&Subsidiaries that are leased to the following"Client Company": Blue Panther Roofing&Construction Corp Coverage only applies to injuries Incurred by South East Personnel Leasing,Inc.&Subsidiaries active employee(s;,while working In:FL Coverage does not apply to statutory employee(s)or Independent contractor(s)of the alent Company or any other entity. A list of the active employee(s)leased to tate Client Company can be obtained by faxing a request to(727)937-2138 or by calling(727)938-5562. Project Name: ISSUE 10-12-15(PH) Bealln Date 4 9 2015 CERTIFICATE HOLDER CANCELLATION CITY OF MIAMI SHORES Should any of the above described policies be cancelled before the expiration date thereof,the issuing BUILDING DEPARTMENT insurer will endeavor to mail 30 days written notice to the certificate holder named to the left,but failure to do so shall impose no obligation or liability of any kind upon the insurer,its agents or representatives. 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 �'� e wacA-Am I 7066 SW 4,e Street Miami, FL 33155 Tel:786-398-9179 Fax 786-800-2627 al mofinsoectionfl-gmail.com LAB CERTIFICATION #10-0512-01 SITE SPECIFIC INFORMATION UPLIFT TEST—TAS#106 Roofing Contractor 13LUE PANTHER ROOFING Permit# RF10152590 Job Address 51 NW 91 ST MIAMI SHORES,FL. Owner's Name ROSAJIMENEZ Type of Tile CROWN Date Installed Approximate Roof Height 12' feet Roof Pitch 3/12 Type of Access to Roof LADDER Approximate Square Footage of Roof 26.0 ft2 Required Testing Force 35 Lbs Date Tested 11to9/15 Number of Tests 60 Testing Equipment F.G.E.100 Contact Name JUAN HERRERA Phone# 7/255-6061 LOCATION #OF TEST PASS #OF TEST FAIL Corner 9 Tests 9 Pass Test o Fail Perimeter 10 Tests 10 Pass Test 0 Fail Field 28 Tests 28 Pass Test 0 Fail Ridge 13 Tests 13 Pass Test 0 Fail TOTAL 60 Tests 60 Pass Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106,THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST.THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY,WITH NO DEVIATIONS.THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS.THIS REPORT IT IS NOT VAUD FOR INSURANCE CLAIMS. y r YENAN T.�:EYYA P.E.#6741,6"; .f A-1 Engineering Inspection Services, Inc 7066 SW 44 Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 al roofmspectionggmail.com LAB CERTIFICATION# 14-1215.04 11/09/15 PERMIT. #RF10152590 51 NW 91 ST MIAMI SHORES,FL. T T T T T T T TT T T T T T. T T T T T T TT T T T T T T T T T T T T 7066 SW 44`x'Street Miami,FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 ,a aOFFICE OF THE Summary Report Generated On:10/13/2015 Property Information .''' Folio: 11-3101-000-0172 Property Address: 51 M91 ST Owner ROSE M JIMENEZ ' y Mailing Address 51 NW 91 ST MIAMI SHORES,FL 33150 Primary Zone 0800 SGL FAMILY-1701-1900 SQ d Primary Land Use 0101 RESIDENTIAL-SINGLE FAMILY:1 UNIT Beds I Baths I Half 3/2/0 8 r Floors 1 Living Units 1 Actual Area 1,799 Sq.Ft awe Living Area 1,475 Sq.Ft Adjusted Area 1,629 Sq.Ft Lot Size 12,012 Sq.Ft Taxable Value Information Year Built 1956 2015 2014 2013 Assessment Information County Year 2015 2014 2013 Exemption Value $50,000 $50,000 $50,000 Taxable Value $83,349 $82,291 $80,336 Land Value $195,113 $161,865 $108,493 School Board Building Value $113,378 $110,446 $110,446 Exemption Value $25,000 $25,000 $25,000 XF Value $0 $0 $0 Taxable Value $108,349 $107,291 $105,336 Market Value $308,491 $272,311 $218,939 city Assessed Value $133,349 $132,291 $130,336 Exemption Value 1 $50,000 $50,000 $50,000 Benefits Information Taxable value 1 $83,349 S82,2911 $80,336 Benefit Type 2015 2014 2013 Regional Save Our Homes Assessment Exemption Value $50,000 $50,000 $50,000 Cap Reduction $175,142 $140,020 $88,603 Taxable Value $83,349 $82,291 $80,336 Homestead Exemption $25,000 $25,000 $25,000 Second Sales Information Homestead Exemption $25,000 $25,000 $25,000 previous OR Book- Sre price Page Qualification Description Note:Not all benefits are applicable to all Taxable Values(i.e.County, 9 School Board,City,Regional). 03/23/2011 $51,500 27694-1833 Corrective,tax or QCD;min consideration Short Legal Description 07/01/1996 $100,000 172643176 2008 and prior year sales;Qual by 153 41 .28 AC M/L exam of deed E84FT OF W294FT OF S178FT OF SE 05/01/1991 $92,000 15023-2320 2008 and prior year sales;Qual by 1/4 NW1/4 SE1/4 LESS S35FT I exam of deed LOT SIZE 84 X 143 05/01/1989 1 $0 14099-1377 1 Qual by exam of deed OR 172643176 07961 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at httpJ/www.miamidade.govfinfo/disclaimer.asp Version: • • • � ; :: is ISI i i 0 0 • • ■■■■■■■O■i ►i■■N■■■O■■■O■■■■N■■■■■t■■■■■■■■■■■N■■■■■■■■NOON ■I 1\NOON■■■N■■■■N■I.I I■■■■■■■■■■■■■■■■■■■■■■■■■■!N■!■■■■�ii�Gii ■■Il■■1•NN■■■�I■■■■II■■t I■■■■■■■■^.,��■■N■N■■O■■N■■■■�ee�n■■■r�n�� ■■It■■■�■■N■Ir■■NDN■■11■■■■■����������������N■■■NNNa■■N■■■■■ C■I NOON■\\■■■■Ii■■■■I■■■■■■■■■■■■■■■■■■■■■��N■■■■etZtN■■■�■�� ■I■■�■r■.I.■■■►�■■Ori■■■■■■■■■■■N■YON■■■■►�■■■�■111 �■rrrN■■■i■■■ Vii■■■NII■N■■N■'it■■■■■■■■■■w■■■■■■■��■■NiNr;��_C����Y■■SiAaL7 ■■I■■II■■■■■■■■■■■■■■■■■■■■►�:�..��\NOON■/i■■■N�Gf IZ�l;7N■■■■7■ ■■I t■O►!61■■NOON■■■■N■11■!■■■■iN■II■■■NN■■■■■■•■■i,1rl!N■H■■■n■*PI ■■I NOON■■■1NN■ ■N■■■1I����������������■■■■OOO�:■I IO■■NNNWAMW ■■■■■■■■■■■■■■■■■■■■■■■N■■■■■■■■■■■■■NO■O■■O■ONO■■■■■■■■■ Miami Shores Village Building Department 0000 � 0000. g p ..,�. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit# DATE: INSPECTION AFFIDAVIT I �%,-Ca C' C 0-6 Lt\ licensed as a(n)Contractor/Engineer/Architect, (Print name and circle License Type) FS 468 Building Inspector License#: On or about C. a ' �g q , I did personally inspect the roof deck nailing and (Date&time) Secondary water barrier work at 5( L;L ( S F k 14- (Complete 4-(Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 FS) Signatu .000.6 • .60006 State of Florida 0"• ' 0600 0 6060 006000 666666 County of Dade: •••�0� 0000.. 0000 . 6 The undersigned, being the first duly swom,deposes and says that he/she is the contractor four @ above-prope0rty :.00.0•0••0 60660• P. • 66660 mentioned. ' ' 0000 0000 000009 0000.. 6 6 6 . 00*0% Sworn to and subscribed before me this day of 6 0 000.. • . . 0 r6 . 6 666 • • 4 Notary Public, Sate of Florida at Large 9 Jme k MOAM N#EB31658 EXPIRES: Sept 3, 2016 www.AnoNNoTARY.com 'General,Building,Residential,or Roofing Contractors, an certified under 468 F.S.to make such an inspection.Include photographs of each plane of the roof with permit#and address#clearly shown marked on the deck for each inspection Revised on 5/21/2009 T 1 ,SNORES G Miami shores Village I Building Department 10050 N.E.2nd Avenue FNtes INS Miami Shores, Florida 33138 OR1Dp' Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: I o 10050 NE 2nd Ave Miami Shores, FI 138 Re: Owner's Name: 0,5 K �'V\&xE_V"� � Property Address: iAi Lo Roofing Permit Number: Dear Building Official: I � i tM,F KJfP,iW, certify that I am not required to retrofit the roof to wall connections of my building because: efThe just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 19 ition the South<fWda Building Code (1994 SFBC) v bc,' 'S: t V11 9�• •.... .... . ...... .... ...... Signature Pnnt Name 666:66 sees • ...... • •••••• .... . ..... . . State of Florida •••••• ••••• County of Dade •• •• •• •• •••••• The undersigned, being the first duly swom,deposes and says that he/she is the owner for the abo t4prope ft mat tioned..•.:. Swom to and subscribed before me this % day of 0 C-Ld �� Qf •. ... :"": c � �. Jolt(gron = coaIMisslt if EE831658 Notary Public, Sate of Florida at Large ''� ���.��'' ARES. Sept 3, 2016 "N.AAARNOTARY&M • When the just valuation of the structure for pu ose f ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building appli . n from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 t SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 84402.13.1 Scope.As it pertains to this section,it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initial in the adjacent box indicates that the item has been explained. 1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics (appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. Q- 2.Renalling Wood Decks:When replacing roofing,the existing wood roof deck may have to be renaa6d in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system.) 3. Common Roofs: Common roofs are those which have no visible delineation between neig boring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4.Exposed Ceilings:Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance,therefore,roofing nail penetrations of the underside of the decking may not be acceptable.This provides the option of maintaining this appearance. 5. Ponding Water:The current roof system and/or deck of the building may not drain well and may dause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. _ 6.Overflow scuppers(wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water.Perimeter/edge walls or other roof extensions may block this discharge R overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402,R4403 and R4413. 7.Ventilation:Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself).The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the servic,WWO vi ...... the roof. • • • ••• •• •••• owes*: Exception:Attic spaces,designed by a Florida licensed engineer or registered architect to eliminate the attic venting,venting shall not be required. 000000 Owner's/A fentSignature Date Contra o 4e .• �� • Property Address Permit Number Tile Roof Sy9tem MIAMI�DDE ® Miami-Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section D Tile Roof System Roof System Manufacturer: CROWN BUILDING PRODUCT OF FL Notice of Acceptance Number(NOA): 14-1006.02 Minimum Design Wind Pressures,If Applicable(from RAS 127 or calculations): P 1: -39.1 P 2: -68.1 P 3: -100.7 Maximum Design Wind Pressures,(From the NOA Specific system): '26 1 _ psf Fill in the specific roof assembly components.N a component Is not required,insert not applicable(nla)In the text box. t Deck Type: —5/8"Plywood-- ., k Optional Insulation: RNA f. �V Optional Nailable Substrate: Optional Nailable Substrate Attachment: Roof Slope: _4 _ 1/12" NA Roof Mean Height: 16 ft. Basesheet Type: Method of Tile Attachment: ASTM FELT D226 30# • —Adhesive, 2 Small Paddy Polyfoam Polypro— • Fastener Type for Baseshddt AttachmWt:•••. •. Alternate Method of Tile Attachment per NOA: 1-1/4" RS NAIL&TIIyCPgp. -5/8" • NA .... Tile Underlayment(Cap Sheet Type: •. .... BORAL TILESEAL • Drip Edge Size&Gauge: —3"face 26 ga.-- --- • ...... . .... . . . . ...... Tile Underlayment Attaclynent.Method-••••• . Drip Edge Material Type: I—Galvinized Metal-- SELF ADHESIVE •• ••• •• • Drip Edge Fastener Type: 1-1/4"RS NAIL 4"PC Tile Profile: TUSCANY CONCRETE TILE Hook Strip/Cleat gauge or weight: —Select Hook Strip— Srjcflon E i MIAMbDADE Miami-Dade County HVHZ Electronic Roof Permit Form • "Delivering Excellence Every Day" Section E(Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127' For Moment based file systems,use Method 1. Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the the attachment method is acceptable. P 1: -39.1 X 0.313 = 12.24 -Mg: 6.88 =Mr1: 5.36 5 26.1 NOA Mf P 2: -68.1 X X0.313 = 21.32 -Mg: 6.88 =Mr2: 14.44 5 26.1 NOA Mf P 3: -100.7 X X0.313 = 31.52 -Mg: 6.88 =Mr3: 24.64 5 26.1 NOA Mf Method 3"Uplift Based Tile Calculations Per RAS 127' For Uplift based the systems use Method 3.Compare the values for F with the values for Fr.If the F values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. P1: x 1: = x w: _ -W. = X cos e: =Frl: 5 NOA F P2: X 1: = X w: _ .. -W. = X cos 9:El=Fr2: S NOA F P3: " X 1: = X w: _ -W: = X cos 9:El=Fr3: 5 NOA F Where to Obtain Information to complete the calculations Where to Find """ Description Symbol •. 000000 •••:• .• . 0000 ease Table 1 RAS 127,or by an engineer analysis prepared,si nedend sealed by a professional Design Pressure P1 or P2 or P3 engineer based on ASCE 7. ••000 0 :00 6 6 Mean Roof Height H Job Site •Goes 0 :0.0 0 0 ,d Roof Slope 9 Job Site 6.•.•• •66.61 .66.60 Aerodynamic Multiplier Product Approval(N(Ae 0; ' '. Restoring Moment due to Gravity Mg Product Approval(NOA) : 0• . 6 Attachment Resistance Mf Product Approval(NOA) 6 • • 0. Required Moment Resistance Mr Calculated Minimum Attachment Resistance F Product Approval(NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval(NOA) Tile Dimensions I-length w=width Product Approval(NOA) l ' MIAMI-DADE COUNTY MIAMI-DADE) PRODUCT CONTROL SECTION • 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Crown Building Products of Florida,LLC 6018 HWY 72 Arcadia,FL 34266 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tuscany Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has bC%q pp change in the applicable building code negatively affecting the performance of this product. .•. so**** .. 9999 TERMINATION of this NOA will occur after the expiration date or if there has been %ji"PLon or cha tge in th0•••• materials, use, and/or manufacture of the product or process. Misuse of this NOA as an enc"§vment of anyproduc�•see: for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to ceaxtply w1fl thy*section.... of this NOA shall be cause for termination and removal of NOA. 00:00: ••••• •. 90 .• 09 999966 ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, FlpiiW,:md followed by the •, expiration date maybe displayed in advertising literature. If any portion of the NOA is displayed,•then i>: W:be dont***** . in its entirety. :0000: •• • • •.9 INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Juan E.Collao,R.A. NOA No.: 14-1006.02 9999 MIAMI-DADECOUNTW E�Fjyj xpiration Date:01/29/20 Approval Date:01/29/15 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Tuscany Roof Tile, as manufactured by Crown Building Products of Florida, LLC as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Tuscany Roof Tile L= 17" TAS 112 Low profile,interlocking,concrete tile equipped W= 13" with two nail holes.For direct deck or battened H=2.3" nail-on,mortar or adhesive set applications. Thickness: 0.5" Trim Pieces L=varies TAS 112 Accessory trim, concrete roof pieces for use at W=varies hips,rakes,ridges and valley terminations. Varying thickness Manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) 3MTm 2-Component Foam Roof Tile Two component polyurethane 3M Company :...: Adhesive AH-160 foam adhesive. • • •••••• TILE BOND'"'Roof Tile Adhesive Single component polyurethane The Dow Qbggi%al CoMpppy• 6 e 0„0 foam roof tile adhesive. 686:90 9 6666.. "Tile Tite"Roof Tile Mortar Premixed,pre-bagged roof tile Bermudg ro'hf Co666 . 4w..;. ' 6 . 6666. mortar. • Bonsai Roof Tile Mortar Premixed,pre-bagged roof tile Bone&Nogriericai.• e: .••... mortar. •••••• 6 6 "Quikrete"Roof Tile Mortar,FL-15 Premixed,pre-bagged gray roof The Quikrgte Cgmpanits!ine.• 0 e • tshe mortar. ..6 ... 669969 69 6 2.2 MANUFACTURING LOCATION 1. Arcadia,FL NOA No.: 14-1006.02 MIAMI•DADECOUNTY Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Resort Date Redland Technologies 7161-03 PA 102&PA 102(A) Dec. 1991 Appendix III 7161-03 Appendix II PA 108(Nail-On) Dec. 1991 Letter PA 108(Nail-On) Aug. 1994 P0631-01 PA 108(Mortar Set) July 1994 P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs.smooth shank nails The Center for Applied. 94-083 PA 101 (Adhesive Set) April 1994 Engineering,Inc. 94-084 PA 101 (Mortar Set) May 1994 25-7094-(1,4,&7) PA 102 Oct. 1994 25-7183-(1,2&7) PA 102 Feb. 1995 25-7214-(2&6) PA 102 March, 1995 25-7487-1 PA 102 Dec. 1995 25-7496-(2&3) PA 102 Dec. 1995 25-7804-5 PA 102 Sep. 1996 Celotex Corporation Testing 528454-2-1 PA 101 Sep. 1998 Service 520109-2 PA 101 Dec. 1998 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 Evaluation Calculations 25-7183 March 1995 Evaluation Calculations 25-7094 February 1996 Evaluation Calculations 25-7496 April 1996 Evaluation Calculations 25-7584 December 1996 Evaluation Calculations 25-7804b-8 December 1996 Evaluation Calculations 25-78044&5 December 1996 Evaluation Calculations 25-7848-6 Dj&"ber 1996.... Evaluation Calculations Aerodynamic Multipliers%.• ; AWL 1999 so Evaluation Calculations Two Patty Adhesive Set Systs":of %pri`?999 ....;. ..offs f American Test Lab of South RT0908.02-14 TAS 112 00000 ;05418114 Florida RT0912.02-14 Restoring Moments 0000 909/18/14 ff;•f Aerodynamic Multiplier":": .' . : .. .. .. .. ...... f . . . . ...... MIAMMADEco� ENOio No.: 14-1006.02 � � Expiration Date:01/29/20 Approval Date:01/29/15 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Tuscany Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W) and Dimensions (I x w) Tile Profile Weight-W(lbf) Length-I (ft) Width-w(ft) Tuscany Roof Tile 10.0 1.42 1.08 Table 2: Aerodynamic Multipliers -,k (fe) Tile Profile It (ft ) A(fe) Batten Application Direct Deck Application. Fuscany Roof Tile 0.289 :0.313 ' Table 3: Restoring Moments due to Gravity-Mg (ft-lbf)� •;• • Tile 2"•12" 3":12" 4":12" 5":12" 6":12"'. 'Mi;" or • Profile ' greater ...... . • •.••• Tuscany Battens Direct Battens Direct Battens Direct Battens Direct Batten . Kect Barris.:Direct..... Roof Tile Deck Deck Deck Deck •0pok Deck .' 7.06 7.06 6.99 6.99 6.88 6.88 6.73 6.74 6.57 6.5f 6.3to 0 9•••• • . . NOA No.: 14-1006.02 MIAMI•DADEC )UNTY Expiration Date:01/29/20 AD Approval Date: 01/29/15 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19132" plywood) plywood) Tuscany Roof Tile 2-10d Ring Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank 8.8 11.8 4.1 Nail 2-10d Smooth or Screw Shank 16.4 21.9 7.1 Nails 1 #8 Screw 25.8 25.8 22.9 2#8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank 24.3 24.3 24.2 Nail (Field Clip) 1-10d Smooth or Screw Shank 19.0 19.0 22.1 Nail (Eave Clip) 2-10d Smooth or Screw Shank 35.5 35.5 34.8 Nails (Field Clip) 2-10d Smooth or Screw Shank 31.9 31.9 32.2 Nails (Eave Clip) 2-10d Ring Shank Nails 43.0 67.5 50.9 1 Installation with a 4"tile headlap and fasteners are located a min. of 2'/"from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Patty Adhesive Set Systems . ""•' Tile Tile Application ""nlum nenta • ...... Profile ...%LResistange Tuscany Roof Tile Adhesive 2 See manufacturers component approval for installation requirements. ••• ••• 3 TILE BONDTm Roof Tile Adhesive;Average weight per patty 11.4 grams. ..'..' ...... 3MTm 2-Component Foam Roof Tile Adhesive AH-160;Average weight per patty 8 grams...... . . . . ...... NOA No.: 14-1006.02 MIAMIDADEC0j Expiration Date:01/29/20 Approval Date: 01/29/15 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Tuscany Roof Tile 3M 2-Component Foam Roof Tile Adhesive AH-160 86.61 3M 2-Component Foam Roof Tile Adhesive AH-160 45.5 4 Large paddy placement of 54 grams of 3MTm 2-Component Foam Roof Tile Adhesive AH-160. 5 Medium paddy placement of 24 grams of 3 M 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Tuscany Roof Tile Mortar Set5 20.6 6 Seespecific mortar manufacturer's Notice of Acceptance 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami-Dade County Product Control Approved". T U H 7 ....% ...... .... ...... TUSCANY ROOF TILE 000000 •'• ' 00:000 (LOCATED ON UNDERSIDE OF TILE) 06:09: •. 6 00000 • • .• .• 00 66 960666 0000•• • • 6 6. BUILDING PERMIT REQUIREMENTS: 6 . . . . ...... 9606•• 6.1 Application for building permit shall be accompanied by copies of the following: •6: 6 0 000 :*Goo: 6.1.1 This Notice of Acceptance. 6..6 • 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-1006.02 MAMI-DADECOUNTY Expiration Date:01/29/20 Approval Date: 01/29/15 Page 6 of 7 PROFILE DRAWINGS FASTENER HOLE FASTENER HOLE 17" 13" 0000.. 0000.. TUSCANY ROOF TILE .. 0000 0000.. 0000 0000.. 0000.. 0000.. 0000 0000.. END OF THIS ACCEPTANCE .. .. .. .. 0000.. 0000.. . . . . 0000.. 0000.. . 0000.. 00 0 NOA No.: 1 MIAM��oADECouNTY Expiration Date:e: 01/29/20/29/20 Approval Date: 01/29/15 Page 7 of 7 MIAMI-RED MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.adaniidade.gov/economy Boral Roofing LLC. 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and Mere•has beep no change ••••;• .. • .... in the applicable building code negatively affecting the performance of this product. • ...... .... ...... ...... TERMINATION of this NOA will occur after the expiration date or if there has been a revisjgq pr change in rhe :0000: materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorwmarlt of APhrduct. ..... for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to•o tly with any lection..:..' of this NOA shall be cause for termination and removal of NOA. •• •• so*** •••••• ADVERTISEMENT: The NOA number preceded by the words Miami-Dade Counfiy, Florida, dad tllowed•.... by the expiration date may be displayed in advertising literature. If any portion of the.NO�t�: is disglaye d,the;.... it shall be done in its entirety. •..' INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#12-1219.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Juan E. Collao,R.A. NOA No.: 13-1113.05 MIAMI•DADECOUNW Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36"x 36' rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood,NH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. R14610 Follow up Service 03/28/02 IRT-Arcon,Inc. 02-012 TAS 103 02/28/02 PRI Asphalt Technologies,Inc. NEI-006-02-01 TAS 103 04/01/02 PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114(H) 07/30/02 PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM G 155 08/08/07 Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM G 155 05/01/08 NEI-076-02-01 TAS 103 /ASTM D4795 ;•0944/11 .... • NEI-034-02-02 ASTM D 1970 '..' .01629/13 .• 0000.. 0000 0000.. 0000.. 0000.. 0000 0000.. 0000 0000• 0 46006 .. .. 0000.. 6006066 0 . 0 6 0 .0600. 666666 0 .000.0 . 0 . 00 0 0 606 0 0 NOA No.: 13-1113.05 MIAMFDADECOUNTY Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 15/32'or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the laps and two staggered rows 12" o.c.the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6"o.c.at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened Roof Tile, Metal Roofing,Wood Shake&Shingles,and Asphaltic Shingle assemblies. %09.46 46..0.. • ...... 0 •0446.9 ...... . . .0... •• •• •9 •• •9469•• • 999••• • • • • • • •9.46•• 999••• NOA No.: 13-1113.05 MLAMI•oAoecouExpiration Date: 07/31/17 Approval Date: 03/13/14 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth,clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. if BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. :9.0:0 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembk p4*nt Pro4l}jt0 Control•*:: Notice of Acceptance and applicable Building Code. 660066 '0 0 0 0' 0 0 9 0:9 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This tam4piece shall be presse f.000 in place and formed around the protrusion to ensure a tight fit. A second layer of BOR.MI!!NeSeal Vgymerft • shall be applied over the underlayment,and sealed using an SBS modified mastic. 6696 ' 00009 15. All products listed herein shall have a quality assurance audit in accordance with the 606094 00r'9 f Buildil •de an 0... P q tY Fl 1d il>:�sQ 5�.9... Rule 61G20-3 of the Florida Administrative Code. 009090 9 0' 16. All membranes or packaging shall bear the imprint or identifiable marking of the manuf;cture;s nanVar Wo,citq•••% and state of manufacturing facility, and the following statement: "Miami-Dade County l:rocUft Contfol Approved:....: or the Miami-Dade County Product Control Seal as shown below of .' :': ' CMLAAM1-MQADMEC0=U END OF THIS ACCEPTANCE NOA No.: 13-1113.05 MIAMI•DADECOUNTY Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 4 of 4 MIAMI-DADE COUNTY lb PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.Wamidade.gov/economy 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN.55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use if it is 's 'ction. RER reserves the right to revoke this acceptance, of such roduct or material within their jurisdiction. P J g determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2-Component Foam Roof Tile Adhesive AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. 0000.. 0000.. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or olmag: in the . materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endotMeiit of any,product,fore•••• sales, advertising or any other purposes shall automatically terminate this NOA. Failure to VIA4)?f with any'section Qf••••; this NOA shall be cause for termination and removal of NOA. a•••• 000.• •. • • 0 ... . 0000. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida•and fodovred by the•••• .. 0a .. ... • expiration date may be displayed in advertising literature. If any portion of the NOA is disWj)j%i,,then it shEJ �ie done •••• in its entirety. . 0000.. .0000. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufac%re'r air its distributors aiV 0 0 0 shall be available for inspection at the job site at the request of the Building Official. 0 0 0 0 This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 MAMWADECOUNTY Expiration Date: 05/10/17 Approval Date:09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing g Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using 2-Component Foam Roof Tile Adhesive AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2-Component N/A TAS 101 Two component polyurethane foam adhesive Foam Roof Tile Adhesive AH-160 Foam Dispenser N/A Dispensing Equipment RTF1000 ProPack®30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. 0 • 000.. 0000.. PHYSICAL PROPERTIES: 0000 0 0000.. 0000 0000:0 Property Test Results... 0 0000.. Density ASTM D 1622 1.6 lbs./ft.3 OGOOOO ' ' ' :.0.:. Compressive Strength ASTM D 1621 18 PSI Parallel to rise •• ••:••0 000.. . 12 PSI Perpendicular to rise* • .. .. . 00000 .. .. 0000.0 Tensile Strength ASTM D 1623 28 PSI Parallel to rise •••••• •• Water Absorption ASTM D 2127 0.08 Lbs./Ft' 0 000000 Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch """ Dimensional Stability ASTM D 2126 +0.07%Volume Change @0-40'F:,2 weeks 0 GO ."". +6.0%Volume Change @1580F., 100%fkAi&ty,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01 MIAM4DADECOUNW Expiration Date: 05/10/17 F-11 2 IOU 4 Approval Date:09/04/14 Page 2 of 11 A EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03(02/92 520109-2-1 :00000 0000.. .. 0000 LIMITATIONS' �: • ' 0000.. 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assemblyow fire rating. . ;""; 0 0 0000•• 2. 3M m 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&'high tib!profiles. ";••. 00.00. . . ..... 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RSCS 120. •..'.: 0 0 0..0 4. Roof Tile manufactures acquiring acceptance for the use of 3M' 2-Component Foam R'oollorle Adhesive AH- •. 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. : 0 :000:0 ••600 5. All products listed herein shall have a quality assurance audit in accordance with the fiori(a Builclicag Code and"": Rule 61 G20-3 of the Florida Administrative Code. •• • NOA No.: 14-0805.01 MIAMI-DADECOUExpiration Date: 05/10/17 • • Approval Date:09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company.3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B"component shall be maintained between 1.0-1.15(A): 1.0 (B). 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or ProPack®30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. 0000 Y • • • • • •010.6 • • ••666• • • ••6•• • • • • • •• •• •• •• •66.6• • •••••• • • ••0••• • • • NOA No.: 14-0805.01 MIAWDADE0DUNTY Expiration Date: 05/10/17 Approval Date:09/04/14 Page 4 of 11 A Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. MAMI•DADE COUNTY .s o BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluatethe ilgstallatiiti bftltis system. ••.s . ••.. • see• 0000.• • • .0000• *see s • • s • 0 •0000• • Soo 00008• • • 0000• • • • e • •. .. 0 0 •. 000000 0000•• . • • . . . • sees% •0.000 . • •0000• 00 0 000 0• s MIAMFDADECOUNTY NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date:09/04/14 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# 1 thfaugh plastkeafftent Paddy! r.Mh ) Flat/Low Profile Tile I"deyr.•na - p s� _` �. 1. Starting at the eave course apply a minimum 2" g , PP Y (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam ? " -A` paddy onto the underlayment positioned as shown, '*"w -. -:' •. under the strengthening rib closest to the overlock ��n►�•-.._- ,�" �,e �� N of the the being set. - 2. Continue in same manner.Insure approximately 17 '' f (109.7 cm2)—23 (148.4 cm2)square inch adhesive m� r •fir . ,.�-' contact with the underside of the tile. Ea"Clusu Nall t1hroughiftskcemar# Medium Profile/ Double Pan Tile When mired) rdoi 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown y a under the pan portion of the tile closest to the overlock of the tile being set. tomo -.. _ 'w am.r,ff.�tai ff =� t 2. Continue in same manner.Insure approximately 17 (109.7 cm )—23 (148.4 cm)square inch adhesive >•. z- w '4'� .' contact with the underside of the tile. �ID?'@C941r#6' - r -.✓- "�.._...Fast Na 9%Fl000 ',.' hn i High Profile/Single Pan Tile ``�-, ��, .mss�;•r�'" /' '� 1. Sitartn at the eave course a a mi 'itirtt?i62" ...... � w r (50.8 mm)x 10"(254 mn%%i"125.4 mu).foam .' ' ``, "`-•_,ate paddy onto the underlaymp&U ppsitionet asA ownYr ....:. under the pan portion of tha>a %closest to tie F r 4 `� Overlock of the the being satBattens .•• �; • •••.• 2. Continue in same mannerlI9�t�tP�appro�Am�t�ly 17 (109.7 cm2)—23 (148.4 cO)Square incl!AdAssive r," � -`' contact with the underside VIVe:ile.Weepthate • gi Yom. • • • �} r 14 irc �fn. .- ��r: •• • MIAMNDADE COUNTY NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date:09/04/14 Page 6 of 11 A ADHESIVE PLACEMENT DETAIL#2 Nail thmush P4014 e•m•,u Flat/Low Profile Tile b 1. Starting at the eave course,apply a minimum 2"(50.8 � .e mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy � � ;y �•,, onto the underlayment positioned as shown under the strengthening rib of the tile closest to the Overlock of the tile being set. Insure approximately 17(109.7 cm)� „•� y —23 (148.4 cm2)square inch adhesive contact with the A underside of the tile. dam,.• � '' 4� ,'ai r:" 2. At the second course apply a minimum 2"(50.8mm Fasdia x 7 (177.8 mm)x 1 (25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the Overlock of the tile EwOCios�ar0 being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm)- 12(77.4 cm)square inch adhesive contact with the underside of the tile. Nail thralh1•sticresnam Medium Profile/Double Pan Tile _T-#mddyIftnealb11101 1. Starting at the eave course,apply a minimum 2"(50.8 ` °•� �� mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy • �e �� onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the ; f tile being set.Insure approximately 17(109.7 cm2)— 7 en:• e. 2 23 (148.4 cm)square inch adhesive contact with the underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) 'Z. ,,,--- x 7"(177.8 mm)x 1"(25.4 mm) foam paddy onto the underlayment positioned as shown under he.M � •� = _, �'� portion of the tile closest to the ov%lock crf the tile "•':' 3 t' Nec" being set. •• • •••• • r • 0.0.00 ••6• ••6.66 3. Continue in same manner. Insure a'iproximate1% 12" j•••• (77.4 cm2)- 14(90.3 cm2)squat:inch adhesive• 6.6•• contact with the underside of��i�lk • 000000 *0000: ...... ...... • 6 (Instructions continued on nexj pakej •••••• . •00.6• NOA No.: 14-0805.01 MIAMFDADECOUNTY Expiration Date: 05/10/17 e Approval Date:09/04/14 Page 7 of 11 ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) sdwough ptntk as --,1High Profile/Single Pan Tile �ux'han eci�rirsfd'd �a�1�r��.rIaTit�s . 1. Starting at the eave course,apply a minimum 2"(50.8 - x-. mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the :> pan portion of the the closest to the overlock of the the being set.Insure approximately 17(109.7 cm2)— ' 23 (148.4 cm2)square inch adhesive contact with the •ns,�ariI :ti• ��`` '� �� underside of the tile. ~_ !; ' ✓' 2. At the second course,apply a minimum 2"(50.8mm) E•+�� = � r� ems,® x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the Punderlayment positioned as shown under the pan Eawdalwo portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2)- 19(122.6 cm)square inch adhesive contact with the underside of the tile. 0000.. 0000.. .. 0000 • • 0000.. 0000 0000.0 0000.. • 0000.. 0000 0000.. 0000 . 0000. 00000. . 0 00000 . .. ... .. .. 0000.9 . . . 0000.. 0..000 • • • • 0 . 0 .0000. NOA No.: 14-0805.01 MIAMI•DADE COUNTY Expiration Date: 05/10/17 � Approval Date:09/04/14 Page 8 of 11 ADHESIVE PLACEMENT DETAIL#3 Mai►dmuoplaMccement Paddy(between tneQ twhenregml edt 1. On the cave course only,apply a minimum 2" (50.8 �n i.r &- mm)x 10"(254 mm)x V (25.4 mm)foam paddy enstvndertue► onto the underlayment positioned as shown,under Y e sinveiaw the strengthening rib for flat tile or under the pan ;t an"Pottle - - portion of the tile for low or high profile tile closest tothe overlock of the tile being set.Leave dffiAht approximately 4"(10 1.6 mm)up from the cave sinotewdy �< �,� edge free of foam to prevent the expanded adhesive 2X41n• from blocking the weep holes. Insure approximately 17-23 in (109.7-148.4 cm)of adhesive contact with the underside of the tile �F in. Nita d Ye X04 2. Apply a 4"(101.6 mm)x 4" n(101.6 mm)x 1 (25.4 mm)foam paddy onto the underlayment just below FlatlLow Pro€IleTile the second course line positioned foam paddy under the strengthening rib for flat tile,or under the NaUthromp plasticcenwnt SMOepWdyundertfle pan portion of the tile,closest to the underlock for twhen requlrers p„�,� Wes)� „� ' the second course the to be installed. Insure F approximately 8-9 int(51.6-58.1 cm2)of adhesive Battens Rad (Unft contact with the underside of the tile. optional oeaf �q *� (Instructions continued on next page) gg pp x 41n. ffi dirt; und2rtaa�� ��d�ti phr`. ,`.`Z lin. Ewe Dasure EaweCourse Modlum ProflleTlle • • •••••• •••• •••••• • • • • •••••• see • • NOA No.: 14-0805.01 M►AMFDADECOUNTY Expiration Date: 05/10/17 r r Approval Date:09/04/14 Page 9 of 11 ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) man ftwo ptasdc stye ,under die twhenreq�u 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x 3/4" `' ° Paddy ibeZweendksq (19 mm)paddy on top of the eave course tile pa wytun�dtet surface as shown,on top of the strengthening rib 1�yr for flat tile or on top of the pan portion of the tile, d closest to the underlock of the first course of tile. , ` Install second course of tile. Insure approximately 4e41n. 'ffi, 9(58.1 cm2)- 11 (71cm2)square inch adhesive contact with the underside of the tile at the overlap ShNfie lsain. and 7(45.2 cm2,)-9(58.1 cm2)square inch Paddy o tie {`'� adhesive contact with the underside of the tile at the head of the tile.Continue in same manner. Eave Course s Fasda Weephob lain``+ ain Fmdowre Dri edge High pMala Ttle • • • •..•r• • •••• • ••••• sees** •sees: •••••• • •••••• • • • • • • •••••• • • • • • 90 0 NOA No.: 14-0805.01 MIAMI•DADECOUNTY Expiration Date: 05/10/17 1 Approval Date:09/04/14 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile 1. Starting at the cave course,apply a minimum 2" 1)Place enough adhesive to achieve 65 to 70 sq.in Steep pitch equ red) tions 50.8 mm x 10" 254 mm x 1" 25.4 mm foam In contact with the pantile. when required) ( ) ( ) ( ) 2)Tum covers upside down.Place adhesive In paddy onto the underlayment positioned as tot In.from outside edge of cover tile. shown under two adjacent pan tiles. Support cave Then Install the tile.Ensure 20 to 25sq.in.contactarea. -Y° tiles from rocking until adhesive has a chance to IUnderlayment ����` � ° cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2)—70(451.6 cm) square inch adhesive contact with the underside Sheathin of the pan tile. g Eave closure ° (motarshown) 3. Turn covers upside down exposing the underside weaphole fascia Board of the tile.Apply a minimum 1"(25.4 mm)x 10" (254 mm)bead of adhesive directly on the inner Remove top portion of the eavecourse cover tile.Abut tosecond course of edge of each side of the cover tile.Leave pantiles.Ensure eave and of pan and cover tiles are Rush at eave line. approximately 3/4"(19 mm)to 1"(25.4 mm) Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20(129 cm)-25(161.3 cm2)square inch contact area on each side of the cover tile to the pan tile. Continue in same manner.Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. • 5. When additional nailing ' ;is required,;- -8 ...... mm)x 4"(101.6 mm)rfailets 8r the do 4*iEe •• system using galvanized�estainless steal;et• •••••• copper wire and compatibl;nails may housed. ;0000; 0000 0000 • 0••0Y 0000.• • • 0000• • • *sea*: END OF THIS ACCEPTANCE " " ••••*• 0000.. . . • . . . . 000069 0000.. . . . .0000. •• 0 . ... so a MIAMI•DADECOUNTY NOA No.: 14-0805.01 t t Expiration Date: 05/10/17 Approval Date:09/04/14 Page 11 of 11