RF-15-2536 (2) J
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-247385 Permit Number: RF-10-15-2536
Scheduled Inspection Date: November 09, 2015 Permit Type: Roof
Inspector: Rodriguez,Jorge
Inspection Type: Final Roof
Owner: WEBER, STEVEN &VIRGINIA Work Classification: Flat
Job Address:1214 NE 92 Street
Miami Shores, FL 33138- Phone Number (631)379-8547
Parcel Number 1132050270480
Project: <NONE>
Contractor: ADVANCED CONSTRUCTION SERVICE GROUP, INC. Phone: (305)457-9970
Building Department Comments
RE-ROOF FLAT AND SHINGLE ROOF Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-245016. Replace broken tile
Tiles two different colors
Failed
Correction ❑
Needed
Re-Inspection
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
November 06,2015 For Inspections please call: (305)762-4949 Page 36 of 42
w
4 C A 1-Z I. A By I 1N; C.
OF
November 6, 2015
Advanced Construction Service Group.
5910 SW 43 PI
Miami, Fl. 33165
RE: TILE UPLIFT TEST
PROJECT INFORMATION PROVIDED BY CLIENT:
1214 NE 92 St
Miami Shores, FL
Folio#: 11-3205-027-0480
Permit#: RF-1015-2536
Date inspected: November 5, 2015
Date completed by: October 23, 2015
Roofing Contractor: Advanced Construction Service Group
Carlab, Inc Project# 15-8126
Testing lab Certificate#: 09-0127.04
Dear Sirs,
In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof
Tile Uplift Test at the above referenced project. This testing was performed in general accordance with
Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of
mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 3480 square feet, and the mean height of the roof
is less than 30 feet above ground surface. The type of tile used for this project was reported to be
Crown Windsor Slate Roof Tile. This tile was reported to have been foamed in place.
At the time of this testing one test was performed for every exterior corner, at least one test for every
100 square feet of roof tile in the perimeter area, and at least one test for every 200 square feet of roof
tile in the field area. The results for this report are valid at the time of testing only. Walking on roof or
any other type of physical disturbance may alter these results.
Based on our test results, we conclude that the installation of the roof tile at the above referenced
project meets the test requirement outlined in the above mentioned protocol. Attached please find a
copy of our test report for your review.
Should you have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfull lom itted,
Sergio Labiste PE 61733
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
TILE UPLIFT TEST
FOR
Residential Building
1214 NE 92 ST
Miami Shores, FL
Project#:15-8126
Test Test load Test Test Test load Test Test Test load Test
(Ibf) Status (Ibf) Status (Ibf) Status
1 35 Pass 37 35 Pass 73 35 Pass
2 35 Pass 38 35 Pass 74 35 Pass
3 35 Pass 39 35 Pass 75 35 Pass
4 35 Pass 40 35 Pass 76 35 Pass
5 35 Pass 41 35 Pass 77 35 Pass
6 35 Pass 42 35 Pass 78 35 Pass
7 35 Pass 43 35 Pass 79 35 Pass
8 35 Pass 44 35 Pass 80 35 Pass
9 35 Pass 45 35 Pass 81 35 Pass
10 35 Pass 46 35 Pass 82 35 Pass
11 35 Pass 47 35 Pass 83 35 Pass
12 35 Pass 48 35 Pass 84 35 Pass
13 35 Pass 49 35 Pass 85 35 Pass
14 35 Pass 50 35 Pass 86 35 Pass
15 35 Pass 51 35 Pass 87 35 Pass
16 35 Pass 52 35 Pass 88 35 Pass
17 35 Pass 53 35 Pass 89 35 Pass
18 35 Pass 54 35 Pass 90 35 Pass
19 35 Pass 55 35 Pass 91 35 Pass
20 35 Pass 56 35 Pass 92 35 Pass
21 35 Pass 57 35 Pass 93 35 Pass
22 35 Pass 58 35 Pass 94 35 Pass
23 35 Pass 59 35 Pass 95 35 Pass
24 35 Pass 60 35 Pass 96 35 Pass
25 35 Pass 61 35 Pass 97 35 Pass
26 35 Pass 62 35 Pass 98 35 Pass
27 35 Pass 63 35 Pass 99 35 Pass
28 35 Pass 64 35 Pass 100 35 Pass
29 35 Pass 65 35 Pass 101 35 Pass
30 35 Pass 66 35 Pass 102 35 Pass
31 35 Pass 67 35 Pass 103 35 Pass
32 35 Pass 68 35 Pass 104 35 Pass
33 35 Pass 69 35 Pass 105 35 Pass
34 35 Pass 70 35 Pass 106 35 Pass
35 35 Pass 71 35 Pass 107 35 Pass
36 35 Pass 72 35 Pass 108 35 Pass
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438
Test Test load Test Test Test load Test Test Test load Test
(lbf) Status (lbo Status (lbf) Status
109 35 Pass 154 35 Pass
110 35 Pass 155 35 Pass
111 35 Pass 156 35 Pass
112 35 Pass 157 35 Pass
113 35 Pass 158 35 Pass
114 35 Pass 159 35 Pass
115 35 Pass 160 35 Pass
116 35 Pass 161 35 Pass
117 35 Pass 162 35 Pass
118 35 Pass 163 35 Pass
119 35 Pass 164 35 Pass
120 35 Pass 165 35 Pass
121 35 Pass 166 35 Pass
122 35 Pass 167 35 Pass
123 35 Pass 168 35 Pass
124 35 Pass 169 35 Pass
125 35 Pass 170 35 Pass
126 35 Pass 171 35 Pass
127 35 Pass 172 35 Pass
128 35 Pass 173 35 Pass
129 35 Pass 174 35 Pass
130 35 Pass 175 35 Pass
131 35 Pass 176 35 Pass
132 35 Pass 177 35 Pass
133 35 Pass 178 35 Pass
134 35 Pass 179 35 Pass
135 35 Pass 180 35 Pass
136 35 Pass 181 35 Pass
137 35 Pass 182 35 Pass
138 35 Pass 183 35 Pass
139 35 Pass 184 35 Pass
140 35 Pass 185 35 Pass
141 35 Pass
142 35 Pass
143 35 Pass
144 35 Pass
145 35 Pass
146 35 Pass
147 35 Pass
148 35 Pass
149 35 Pass
150 35 Pass
151 35 Pass
152 35 Pass
153 35 Pass
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438
N
D
r
m
z -t-
L
T
LL
T
00
IW
U J
1
TT
L L
T y�
T T
T
LL
T
_I
60
LEGEND
+ EIELD TEST
PERIMETER TEST
O CORNER TEST
Z19PC A IZ L A ]B, I N C.
ENGINEER AND PLANNERS
CERTIFICATE OF AUTHORIZATION 6419
8730 S.W.25 ST,MIAM4 FL 33165 TED305 2613512:FAX:305 226-0438
APPR❑X, R❑❑E TEST L❑CATI❑NS AND DIMENSI❑NS