RF-15-2536 (2) J Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-247385 Permit Number: RF-10-15-2536 Scheduled Inspection Date: November 09, 2015 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: WEBER, STEVEN &VIRGINIA Work Classification: Flat Job Address:1214 NE 92 Street Miami Shores, FL 33138- Phone Number (631)379-8547 Parcel Number 1132050270480 Project: <NONE> Contractor: ADVANCED CONSTRUCTION SERVICE GROUP, INC. Phone: (305)457-9970 Building Department Comments RE-ROOF FLAT AND SHINGLE ROOF Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-245016. Replace broken tile Tiles two different colors Failed Correction ❑ Needed Re-Inspection Fee No Additional Inspections can be scheduled until re-inspection fee is paid. November 06,2015 For Inspections please call: (305)762-4949 Page 36 of 42 w 4 C A 1-Z I. A By I 1N; C. OF November 6, 2015 Advanced Construction Service Group. 5910 SW 43 PI Miami, Fl. 33165 RE: TILE UPLIFT TEST PROJECT INFORMATION PROVIDED BY CLIENT: 1214 NE 92 St Miami Shores, FL Folio#: 11-3205-027-0480 Permit#: RF-1015-2536 Date inspected: November 5, 2015 Date completed by: October 23, 2015 Roofing Contractor: Advanced Construction Service Group Carlab, Inc Project# 15-8126 Testing lab Certificate#: 09-0127.04 Dear Sirs, In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 3480 square feet, and the mean height of the roof is less than 30 feet above ground surface. The type of tile used for this project was reported to be Crown Windsor Slate Roof Tile. This tile was reported to have been foamed in place. At the time of this testing one test was performed for every exterior corner, at least one test for every 100 square feet of roof tile in the perimeter area, and at least one test for every 200 square feet of roof tile in the field area. The results for this report are valid at the time of testing only. Walking on roof or any other type of physical disturbance may alter these results. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above mentioned protocol. Attached please find a copy of our test report for your review. Should you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfull lom itted, Sergio Labiste PE 61733 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438 TILE UPLIFT TEST FOR Residential Building 1214 NE 92 ST Miami Shores, FL Project#:15-8126 Test Test load Test Test Test load Test Test Test load Test (Ibf) Status (Ibf) Status (Ibf) Status 1 35 Pass 37 35 Pass 73 35 Pass 2 35 Pass 38 35 Pass 74 35 Pass 3 35 Pass 39 35 Pass 75 35 Pass 4 35 Pass 40 35 Pass 76 35 Pass 5 35 Pass 41 35 Pass 77 35 Pass 6 35 Pass 42 35 Pass 78 35 Pass 7 35 Pass 43 35 Pass 79 35 Pass 8 35 Pass 44 35 Pass 80 35 Pass 9 35 Pass 45 35 Pass 81 35 Pass 10 35 Pass 46 35 Pass 82 35 Pass 11 35 Pass 47 35 Pass 83 35 Pass 12 35 Pass 48 35 Pass 84 35 Pass 13 35 Pass 49 35 Pass 85 35 Pass 14 35 Pass 50 35 Pass 86 35 Pass 15 35 Pass 51 35 Pass 87 35 Pass 16 35 Pass 52 35 Pass 88 35 Pass 17 35 Pass 53 35 Pass 89 35 Pass 18 35 Pass 54 35 Pass 90 35 Pass 19 35 Pass 55 35 Pass 91 35 Pass 20 35 Pass 56 35 Pass 92 35 Pass 21 35 Pass 57 35 Pass 93 35 Pass 22 35 Pass 58 35 Pass 94 35 Pass 23 35 Pass 59 35 Pass 95 35 Pass 24 35 Pass 60 35 Pass 96 35 Pass 25 35 Pass 61 35 Pass 97 35 Pass 26 35 Pass 62 35 Pass 98 35 Pass 27 35 Pass 63 35 Pass 99 35 Pass 28 35 Pass 64 35 Pass 100 35 Pass 29 35 Pass 65 35 Pass 101 35 Pass 30 35 Pass 66 35 Pass 102 35 Pass 31 35 Pass 67 35 Pass 103 35 Pass 32 35 Pass 68 35 Pass 104 35 Pass 33 35 Pass 69 35 Pass 105 35 Pass 34 35 Pass 70 35 Pass 106 35 Pass 35 35 Pass 71 35 Pass 107 35 Pass 36 35 Pass 72 35 Pass 108 35 Pass 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 Test Test load Test Test Test load Test Test Test load Test (lbf) Status (lbo Status (lbf) Status 109 35 Pass 154 35 Pass 110 35 Pass 155 35 Pass 111 35 Pass 156 35 Pass 112 35 Pass 157 35 Pass 113 35 Pass 158 35 Pass 114 35 Pass 159 35 Pass 115 35 Pass 160 35 Pass 116 35 Pass 161 35 Pass 117 35 Pass 162 35 Pass 118 35 Pass 163 35 Pass 119 35 Pass 164 35 Pass 120 35 Pass 165 35 Pass 121 35 Pass 166 35 Pass 122 35 Pass 167 35 Pass 123 35 Pass 168 35 Pass 124 35 Pass 169 35 Pass 125 35 Pass 170 35 Pass 126 35 Pass 171 35 Pass 127 35 Pass 172 35 Pass 128 35 Pass 173 35 Pass 129 35 Pass 174 35 Pass 130 35 Pass 175 35 Pass 131 35 Pass 176 35 Pass 132 35 Pass 177 35 Pass 133 35 Pass 178 35 Pass 134 35 Pass 179 35 Pass 135 35 Pass 180 35 Pass 136 35 Pass 181 35 Pass 137 35 Pass 182 35 Pass 138 35 Pass 183 35 Pass 139 35 Pass 184 35 Pass 140 35 Pass 185 35 Pass 141 35 Pass 142 35 Pass 143 35 Pass 144 35 Pass 145 35 Pass 146 35 Pass 147 35 Pass 148 35 Pass 149 35 Pass 150 35 Pass 151 35 Pass 152 35 Pass 153 35 Pass 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 N D r m z -t- L T LL T 00 IW U J 1 TT L L T y� T T T LL T _I 60 LEGEND + EIELD TEST PERIMETER TEST O CORNER TEST Z19PC A IZ L A ]B, I N C. ENGINEER AND PLANNERS CERTIFICATE OF AUTHORIZATION 6419 8730 S.W.25 ST,MIAM4 FL 33165 TED305 2613512:FAX:305 226-0438 APPR❑X, R❑❑E TEST L❑CATI❑NS AND DIMENSI❑NS