Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-15-1717
Permit No. RF-7-15-1717 ,yuoR Miami Shores VillageM Permit Type: Roof 10050 N.E.2nd Avenue NE Permlt Work Classification:Flat '• ""'" Miami Shores,FL 33138-0000 Permit Status:APPROVED 0'y Phone: (305)795-2204 `ORSIssue Date:7/14/2015 Expiration: Project Address Parcel Number Applicant 186 NE 106 Street 1121360050010 Miami Shores, FL 33138- Block: Lot: CK PROPERTY SOLUTIONS Owner Information Address Phone Cell CK PROPERTY SOLUTIONS 209 NE 95 Street MIAMI SHORES FL 33138- 209 NE 95 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 3,000.00 CITY ROOFING AND CONSTRUCTION (305)248-2994 (305)218-7901 Total Sq Feet: 546 Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF OF FLAT ROOF ONLY Inspection Type: Classification:Residential Tin Cap Scanning:3 Final Roof Roof in Progress Renailing Affidavit Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-7-15-56285 CCF $1.80 07/14/2015 Check#:1091 $721.30 $50.00 DBPR Fee $3.75 DCA Fee $3.75 07/09/2015 Credit Card $50.00 $0.00 Education Surcharge $0.60 Bond#:2787 Permit Fee-New Roof $250.00 Scanning Fee $9.00 Technology Fee $2.40 Total: $771.30 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and ning. Futhermor authorize the above-named contractor to do the work stated. July 14, 2015 Authorized Signature• caner / Applicant / Contractor / Agent ate Building Dep Ment Copy July 14,2015 1 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-247559 Permit Number: RF-7-15-1717 Scheduled Inspection Date: November 12,2015 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: ,CK PROPERTY SOLUTIONS, LLC Work Classification: Flat Job Address:186 NE 106 Street Miami Shores, FL 33138- Phone Number Parcel Number 1121360050010 Project: <NONE> Contractor: CITY ROOFING AND CONSTRUCTION INC Phone: (305)248-2994 Building Department Comments RE-ROOF OF FLAT ROOF ONLY Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-239438. CREATED AS REINSPECTION FOR INSP-238705. Must call for tin cap/cap sheet insp before final Need uplift test and renailing affidavit for final Failed ❑ 07-24-15 Roof O.K. need to replace section of damage sidewalk on the east side of the property. Correction ❑ did not pick up documents required for final inspection. Needed **Please note sidewalk has been repaired*** Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. November 10,2015 For Inspections please call: (305)762-4949 Page 25 of 34 1 Miami Shores Village JUL 9 tots ! Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 I • Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER:(305)762.4949 14-1 FBC 20 1 W BUILDING Permit No. PERMIT APPLICATION Master Permit No. [� I�- Permit Type: BUILDING ROOFING JOB ADDRESS: 19 L K f✓ 10 b _"�" S> City: Miami Shores County: Miami Dade Zip: 3 3 ) '59j Folio/Parcel#: Z [ 3k t r, Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): (� W) PrO 6 e P4-1 5 6 l V+1(0 05Phone#: 3®T 7�-9 31 Address: Z,0 5 N F_ q S_ 5 Lc't,+- +- .5 L) T FC I City:... W I' W, ' 1 IV1OV-' ...5 .��rl State: II p� � �C.� Zip: � f Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Phone#: :�'oS ZL1e> ��la►vj Address: 2-2'700 '--v\/ MX- GT' City: _ MkA 1 State: 'FL Zip: :'�i'lD Qualifier Name: *,&�o Phone#: 2,c! �►�'N� State Certification or Registration#: Cc_L?�Q_7361 Certificate of Competency#: Contact Phone#: —PEK0 V lq 1$ cs Email Address: C-e4-M\Jf::�1 P EV4-1 tT @ CAMAL. c0r A DESIGNER:Architect/Engineer: a Phone#: Value of Work for this Permit:$ ,DC7 Square/Linear rRe ge of Work: 05414 Type of Work: ❑Addition ❑Alteration ❑New air/Replace ❑Demolition Description of Work: F-A-5 est= �t�4"4 �oc>� Oi fL'4 Color thru tile: o(A Submittal Fee$ Permit Fee$ ��U ' CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ �a 1 'T3 d Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this�v The foregoing instrument was ac owledged before me this day of ! ' 20�,by 1 i >1��'� day of E ,20 lS,by ftp FA—VPA, , who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. I y PUBLIC: NOTARY PUBLIC: Zo 00 CL UJ ' 4� �%Z IVIS REY aSig� Sign: MY COMMISSION#FF147325 o x o Print. 1�ts oP E *X(inmission Expires: t'�7 '7-7 My Commiss' n Expires: ye a�a 2U(g O U Z � 0"' T „11.11Iaklk�a ' bVED BY 1 I Plans Examiner ZoningQ b Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) ♦Sloll!" Miamishores V VNIN rd MUM Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 RIDp Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: L (� 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Property Address: Roofing Permit Number: Dear Building Official: certify that I am not required to retrofit the roof to wall connections of my building because: p The just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC)or with the provisions of 1994 edition of the South Florida Building Code(1994 SFBC) � 101 Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this -` day of ' NON 33#uolsslwwo� 1a do�fb, Nota Public, Sate of Florida at Large AL2 «oa'El uef saildx3 •wwoC�W Notary g �� epuolj!o aletS ollgnd�(�'40 : :2c NlldVYVd'0 lNlf • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00Ithe SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Detail by Entity Name 7/8/15 2:29 PM t w Detail by Entity Name Florida Limited Liability Comply_ CK PROPERTY SOLUTIONS, LLC Filing Information Document Number L10000O91747 FEI/EIN Number 273374777 Date Filed 09/01/2010 Effective Date 09/0112010 State FL Status ACTIVE Principal Address 209 NE 95TH ST SUITE 7 MIAMI SHORES, FL 33138 Changed: 04/26/2011 Mailing Address 209 NE 95TH ST SUITE 7 MIAMI SHORES, FL 33138 Changed: 04/26/2011 -egistered Agent Name & Address KOOTTUNGAL, VIJU 209 NE 95TH ST SUITE 7 MIAMI SHORES, FL 33138 Address Changed: 04/26/2011 Authorized Person() Detail Name &Address Title MGRM KOOTTUNGAL, VIJU "InO AIG Or%-rW CT CI IMP: 7 http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail?l...OpropertyMOsolutions&IistNameOrder=CKPROPERTY5OWTIONS%20L100000917470 Page 1 of 2 Detail by Entity Name 7/8/15 2:29 PM MIAMI S410*RES, FL 33138 Title MGRM CROOKS, ENRIQUE 723 CRANDON BLVD#406 KEY BISCAYNE, FL 33149 Annual Reports Report Year Filed Date 2013 04/03/2013 2014 03/10/2014 2015 03/24/2015 Document Images 03/24/2015 --ANNUAL REPORT View image in PDF format 03/10/2014 --ANNUAL REPORT View image in PDF format , 04/03/2013 --ANNUAL REPORT View image in PDF format 04/24/2012 --ANNUAL REPORT View image in PDF format 04/26/2011 —ANNUAL REPORT View image in PDF format 09/01/2010 -- Florida Limited Liability. View image in PDF format V Ccs+vr'i,hL' ,`and Privacy Foiicf�5 State of:Florida,Department of SCate http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail?i...OpmpertMosolutions&listNameOrder=CKPROPERTYSOLUTIONS%20L100000917470 Page 2 of 2 CFN:20150438445 BOOK 29689 PAGE 265 DATE:07/08/2015 03:13:16 PPA DEED DOC 1,989.60 HARVEY RUVIN,CLERK OF COURT,MIA DARE CTY Atter Recording Mail To: CK Property Solutions LLC 209 Northeast 95 Street, Suite 7 Miami Shores, Florida 33138 This Instrument was Prepared By.- Todd y:Todd Faber, Esq. 9041 South Pecos Road, Suite 3900 Henderson, Nevada 89074 SPECIAL DEED This warranty deed,made the day of ,20� V.S. Bank National Association, as Trustee for Steuctused Ascot Securities Corporation Mortgage Fess-Through C rtiBaates, Series=W-BC4,whose mailing address is C/o Ocwen Loan Servicing, LLC 1661 Worthington Road Suite 100, West Palm Beach, Florida 33409, hereinafter called the Grantor, to CK Property Solutions LLC, a Florida Limited Liability Company, whose mailing address is 209 Northeast 95 Street, Suite 7, Miami Shores, Florida 33138,hereinafter called the Grantee. The Grantor, for and in consideration of the sum of THREE HUNDRED SEVENTEEN THOUSAND AND NO/100 DOLLARS(1$317,000.00)and other good and valuable considerations to Grantor paid by Grantee, the receipt of which is hereby acknowledged,hereby grants, bargains, sells,and conveys unto the Grantee all that certain land,situate in Miami-Dade County,State of Florida,viz: LOT 1, BLOCK 201, DUNNING'S MIAMI SHORES EXTENSION NO. 1,ACCORDING TO THE PLAT THEREOF,AS RECORDED 1N PLAT BOOK 41,PAGE 51, OF THE PUBLIC RECORDS OF MIAMI- DADE COUNTY, FLORIDA. Assessor's Parcel Number: 11-2136-005-0010 MORE commonly known as: 186 Northeast 106th Street,Miami Shores, Florida 33138 Prior Recorded Doc.Ref.:Deed:Recorded May 11,2015;HK 29612, PG 1748 Subject to any Restrictions,Conditions,Covenants,Rights,Rights of Way,and easements now of record,if any. And the Grantor does hereby specially warrant the title to said land,and will defend the same against every person whomsoever claiming or to claim the same or any part thereof, by, through,or under Grantor,but not otherwise. TO HAVE AND TO HOLD all of Grantor's right, title and interest in and to the above described property unto the said Grantee, Grantee's heirs,administrators,executors,successors and/or assigns forever; so that neither Grantor nor Grantor's heirs, administrators, executors, successors and/or assigns shall have,claim or demand any right or title to the aforesaid property, premises or appurtenances or any part thereof. Together with all the tenements,hereditaments and appurtenances thereto belonging or in anywise appertaining. CFN:20150438445 BOOK 29689 PAGE 266 In witness whereof,the said Grantor has signed and staled these presents the day and year first above written. When the context requires,Singular nouns and pronouns include the plural. V.& Bank National Association, as Trustee for Structured Asset Securities Corporation Mortgage P998-Thfoagh Ceftifimtes.Series 2007-W-4.by Ocwen Loan Servicing,LLC as attorney in ce –6 L3Y: Q " Y.J Signature jatqWM S.Mk ae ' cumftwoducew Printed Name&Title Signed, sealed and delivered in the presence of mitt /� j (CORPORATESEAL) Witness Signature: /"6d t Witness Name(Print): S 0 Witness Signature: Witness Name(Print): Chis H&1&aIt STATE OF ss A COUNTY OF VY, ' regoing instrument was acknowledged before me this day of 20 by JaD4UW=&MMMISM (name of signor or agent) as (title of signor or agent) of Ocwen Loan Servicing, as rneg to fact for UJL Bank National Association, as Trustee for Structured Asset Securities Corporation }gs-ThroL_ catea,Series 2007- WA4 (name of corporation acknowledging), a C `3C.�I.�/ (state or p incorporation) Limited Liability Company, on behalf of the limited Liability Company. HLSh*e is personally known to me or has produced P *0M TO M9 (type of identificad identification. NOTARY STAMP/SEAL R,eor° Notarq Public State of Florida 4 .tartl Damm� ;►� MY CWUM"tM FF(rural NOTARY Fugues 04MM017 B .)SRI)DO(Obi$)a PRINTED NAME OF NOTARY PUBLIC — My Commission Expires: Loan 07100797005 2015-07-08-20-02-Olipg 7/8/15 8:14 PM cm 20i4.4--oameCv^t2s493 PAGE 59? womm or 1Oulow III LY+svrJr, CLERK 3F+COilltt-rat.-nA�tc v Fri... __..,_.�wbJ+a�+l ` SMOFFUNM �e�i�iartn��dtlh ► i ,�1atpinionngYo�s raahamiaMYa>�s� , tae�nawew kr w,ot raaaedll�Deas a1ktB ir1lgi>1!!!�i rMy; • N�M11BgdlgRJlt♦� ♦ gi�; it � � �I pt+onrrssrrlb�er . rtAvI name w4J T: q*af!Wft*s Et4p�lF&&dmkMW%Wft76fgMvgt8OdW= &ftmWft nW be sowdaspwAdWtw a w1NdW"��1 f'Pi.Rit IMT�'tw�!a'�-- �0.�eseaolplteca/ttved��•-wraa..w.ww r— _ _ _ ,+...n ......._._.._..�._---.e.er..®. it 0000 dift of#6 NOw of ComRwjcmra* osawmaw dolt Fowull" 914101FOW �a�i�otu�i� iR 7i;2,'f�Wt't AFI Fi�.i9�P11 /11��FIST�i R4il'IJ4Q'Yt�i6'6C1it A OW 7D YOUq➢ G it 0� !elBi'91C R ,y �gt>ep rOpt &fi@ PJi1l N111 ........ PM KaTle •a 'YOFN1Mi1W{�O11DE R I1; A bleatsfDtt " o- �klt tYlY91lC Y tmft p1mw"t l P ��41ate9 Mia0 thB ' NeL� •SiiRe M W6 �3 i urr s"ta f t b ��. s ra I about:blank Page 1 of 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES C 1TED A Florida Building Code Edition 2010 High-Velocity Hurricane Zone Uniform Permit Application Form. �� Section A(General information) Master Permit No._4-� � Process No. Contractor's Name Ct�11' t70FI�L+ Job Address t4r 10V S� ROOF CATEGORY 0000 Low Slope ❑ Mechanically Fastened The ❑ Mortar1Adhpslvg6•et Tile•••••• ••••;• ❑Asphaltic ❑ Metal Panel/Shingles ❑ Wood ShingWWAhakes ••: ....:. Shingles • 00 ❑Prescriptive BUR-RAS 150 •••. .••• • ••.• •.•• ••... ROOF TYPE 0000•• • • 0 ••• 00:00• • • •• •• 0000 0000•• 13New Roof Reroofing 13Recovering 13Repair 134"niienance •• 0 ROOF SYSTEM • • :000:0 •00000•••• INFORMATION •• •• •so 0 • • 0000•• • • • Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF) •• • v514�o q) Section E (Roof Pian) Sketch Roof Plan:Illustrate all levels and sections,roof drains,scuppers,overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly Identify dimensions of elevated pressure zones and location of parapets. �— CA M �\ n �l 15.32 FLORIDA BUILDING CODE—BUILDING t ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High-VModty Hunf+ane Zone thWorm Permit AWIcatlon Farm, Section C(Low Slope Application) Surfadng: Fits in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment: (if a component Is not used,Identity as"NA") ® Field: �—"-oc� System Manufacturer- [ ,- Perimeter: "oc M Lap,#Rowe�_@ oc Product Approval Na: i°3 m 12.1�1.0 Corner;.�3'_"oc®Lap,#Rows?) �� *'.oa• Design Wind Pressures,From RAS 128 or Calculations: . '.•••' •••• PnmW•`41% Pmax2.--11'l PmwO.-109-® Number of Fasteners Per Insula $acrd: •••• •. Field W h 4x:-OO .... .... . Perimeter :.• Comer p��`-j'-�' ...: Max.Design Pressure,from the specific Pr Approval system: 152.w • .••••. •••••• Illustrate Components Noted and•8etalis as •••• ••• Applicable: 000000 . .. :.•' ripe; W O0 Continuous Cleat SWp,Base•F�IgVVgg,er,Edge Counters,��� ••.'• Gange/Thlakness• isle"l a1 swoot), mashing,Coping,Etc. • • • • . . . ..s.. —�P—� irk:Mean Roof Height,Parapet Height, Hei§fkdfgase . Flashing,Component Material,Materia•I•Tfjckness,JgWier •••• Slope: 2-5 Type,Fastener Spacing or Submit so.* Anchor/Base Sheet&No.of Ply(s): ,21.EIr:35 JOSE gm 1� ACIV' ,®e oNoo b ewe 1!IL s NO h Andwrr/Base Sheet F ondirtg Material: 1 o'y_p ta.15 1 T�s4 UAv2 bfiP : 3X3 e6hWANir.eo Insulation Base Layer: N 1 fi �� e 1%191" 9.I5 4 [!� Base Insulation size and Thi: Base Insulation Fastener/Bonding l: T op IN Top Insulation Layer: N 1 A Top Insulation Size and Thicimess: 0A BASe Sheet Top Insulation Fastew/Bonding Material: Base Sheet(s)&No.of Ply(s): 42 XMAW i5 Me- Base Sheet Fastener nding al- -L== A �lr� 0 Ply Sheet(s)&No.of Ply(s): MA Qpp Ply Sheet Fastener/Bondingilaterial• AI .n Top Ply:�ty EIA SWF%eX S 15 T Top Ply Fastener/Bonding NiateriaiALF �' % FLORIDA BUILDING CODE-BUILDING k 3, v 4 0%w,0 Notif4*tion Farm HVHZ 2010 MIAM "Ueldvering ExcWlenc-e Every slay" SECTION 1524 HIGH VELOCrry HURRICANE ZONES—REQUIRED OVYTJM NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code,Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor. The owner`s initial in the designated space indicates that the item.has been explained. 1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone)are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics(appearance)are not a consideration with respect to workm provisions. Aesthetic issues such as color or architectural appearance,that are not part of a zoning:jgde. shoVc� addres;ed as part of the agreement between the owner and the contractor. •••••• ••••'• 000:0. 0000.. A 2.Renailing wood decks: When replacing roofing,the existing wood roof d®okjqay hgreft�be • • renailed in accordance with the current provisions of Chapter 16(High Velocity HurricW Zones�'ot1he Flq>:r • Building Code. (The roof deck is usually concealed prior to removing the existing rooMysfem) .'•:••" ••••;• 000000 0 o/ ' 3.Common roofs: Common roofs are those which have no visible delineatidn BeAveen:nerj boriag••% Y • Y.1� units(i.e. townhouses,condominiums, etc.). In buildings with common roofs,the roof euntractor and/or :•••• owner should notify the occupants of adjacent units of roofing work to be performed. 0 0 V 4.Exposed ceilings: Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below_ The owner may wish to maintain the architectural appearance;therefore,roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5.Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond(accumulate)in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. JA 6.Overflow scuppers(wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge wails or other roof extensions may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code,Plumbing. V j(7.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly(the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate the attic venting,venting shall not be required. Ownees/Agent's Signature: � � G fl m Date: Contractor's Signa Permit Number: Property Address: d3" KIAK MIAMI DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINLSTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) wwww mtamidade gov/eeonomy Polyglass USA,Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). ...... This NOA shall not be valid after the expiration date stated below.The Miami-Dade County t-rsdugt Conlgt§%tion •- •0:6`• (in Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve tbpj"to have this„ ....:. product or material tested for quality assurance purposes.If this product or material fails to pAfq-nin the accepted manner,the manufacturer will incur the expense of such testing and the AHJ mayimmediateI wwke,modiig 0 • suspend the use of such product or material within their jurisdiction. RER reserves the right ivAe this ;a Lance,••;••. if it is determined by Miami-Dade County Product Control Section that this product or matert2d:&KS to meet4he. 00 so *see requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florkl'a'�ulding Code• •;; including the High Velocity Hurricane Zone of the Florida Building Code. """ V: DESCRIPTION:Polyglass Self-Adhered Roof System over Wood Decks •• LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 13-0514.10 and consists of pages 1 through 33. The submitted documentation was reviewed by Alex Tigera. 00 NOA No.: 13-1217.01 M cane Bout Expiration Date: 10/11/17 • Approval Date:11/06/14 Page 1 of 33 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Cateaorv: Modified Bitumen Materials SBS/APP/FPO Deck e: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Descrivdou Elastobase 65'2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I base sheet. XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type I base sheet. Polyglass G2 Base 108'x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet Type 11 Polyanchor 250'x 48" ASTM D 4601 A polymer woven,high performance,synthetic base Type Il sheet. Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced,SBS (1.5-mm) Type I modified bitumen membrane with a self-aiihoaing back face and a smooth top surface. ••• •••• •••••• Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiber�ass reinforced;kS •• . . ...... PLUS FR Type I modified bitumen membra4e a, self-adhgrin..g back . face and a smooth top surface,... '000000 :0 0 0 0: Elastoflex SA V(1.5- 66' 8"x 3' 3-%" ASTM D 6163, Self-adhered,fiberglass reinfbtddd,SBS n1dMed 0 0:0 0. Type I bitumen membrane with a se?f adhering Saok0 race ad 0 0.0 .. .. •••• •••••• a smooth top surface. • Elastoflex SA V 66' 8"x 3' 3-Ng" ASTM D 6163, Self-adhered,fiberglass rei;foraec SBS:4g4�fgd •0•••• PLUS Type I bitumen membrane with a stlf-4d1wring back face and:0.0.: a smooth top surface. 00 000 :•: • •• • XtraFlex SBS Base 66' 8"x 3' V/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified SA Type 1 bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced,SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced,SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. NOA No.: 13-1217.01 Mtar7tnane eouw rr Expiration Date: 10/11/17 ,...• Approval Date:11/06/14 Page 2 of 33 Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32' 10"x3' 3-3/9" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x3'3-3/811 ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10"x 3'3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex SA P 32' 10"x 3' 3218" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32' 10"x 3' 3j/g" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex APP G SA 32' 10"x 3' 321s- ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 3j/811 ASTM D 6164, Self-adhered,fiberglass reinforced,SBSg8di'fWd Type I bitumen membrane with a Self-adhering bW?face and a granule top surface. •• ••• • ...... .. ...... Polyfresko G SBS SA 32' 10"x 3'3-3/8" ASTM D 6164, Self-adhered,fire-rated,fibarg:ws reinforced,SBS •••• FR Type I modified bitumen membrape,*44 a self;a&mrjng back • face and a granule top surfaee•• *see ••:••. ...... . .. ..... Polyfresko G APP SA 32' 10"x 3' 3 3/8" ASTM D 6222, Self-adhered,polyester reipf&p@d,APP•ruOMed ...... Type I bitumen membrane with a self adhering back face and a granule top surface. •••••• Polyfresko G APP SA 32' 10"x 3' 321811 ASTM D 6222, Self-adhered,fire-rated,pAjVtegreinforgec,.4PP ;•'•• FR Type I modified bitumen membrane with a selfNt4lftft back face and a granule top surface PolyKool 32' 10"x 3' 3-%" ASTM D6222 Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S 32' 10"x 3' 33%" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 3-%" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type I base sheet. NOA No.: 13-1217.01 MiaraMREcou Expiration Date: 10/11/17 �Invymfnqlj Approval Date: 11/06/14 Page 3 of 33 PG325 Cold Process 1,3,5,50,55 gal.or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. PG100 Asphalt Primer 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz.spray selected asphalts used to promote adhesion. can XtraFlex 10 Asphalt 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of Primer tube or 17 oz.spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1,3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type III modified bitumen membranes. PG400 Plastic Roof 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement ' tube ASTM D3409 dry or damp conditions. PG450 Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement. Cement tube PG500 MB Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1,3,5,50,55 gal,or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. XtraFlex 35 Premium 1,3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. Polyplus 45 Premium 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement. Flashing Cement tube •••• • . . .... ...... Polyplus 50 Premium 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized,€] ng ce gt fir use MB Flashing Cement tube with modified bitumen membranes. '.: •••• • XtraFlex 50 Premium 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberize$`RIMing cementfor use :•••• 0*00 Modified Wet/Dry tube with modified bitumen meaibrMos.*000 '....• ..... Cement • Polyplus 55 Premium 1,3,5,50,55 gal.or ASTM D4586 A mastic compound for use asw oof flashtV Modified Flashing tube adhesive. •• '• ...... Cement .. . • ••• so NOA No.: 13-1217,01 MIq{p DADS Cou Expiration Date: 10/11/17 • ' Approval Date:11/06/14 Page 4 of 33 APPROVED INSULATIONS: TABLE 2 Product Name Product Descrintion Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA,Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA,Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CG PolyisocyanurateJperlite composite insulation Hunter Panels,LLC ENRGY-3,JM ISO 3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation 6666 . . .006 609..6 6666.. .. 6 666600 6666 . .99..9 6666 6666 • 9 6666 6666 90 96. 00000 • 9669.09 . 9.•. . . . . 0**.: ...... . 00 0 NOA No.: 13-1217.01 Mwt�uane ccuNn Expiration Date: 10/11/17 Approval Date:11/06/14 Page 5 of 33 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Descrintion Dimensions (With Current NOA) 1. Dekfast Fasteners 12, 14& insulation fastener for wood, SFS Intec,Inc. 15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2 7/8"x SFS Intec,Inc:. Hex Plate 31/4's 3. #14 Roofgrip Insulation and membrane Various OMG,Inc. fastener 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3"square OMG,Inc. 5. Trufast#14 HD Fastener Insulation fastener for steel and Altenloh,Brinck&Co. wood decks U.S.,Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co. Plate plate 3"round U.S.,Inc. 7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various Polyglass USA,Inc  steel and concrete decks 8. Polygrip Hex Plates Galvalume hex stress plate. 2 7/8"x Polyglass USA,Inc 3 '/4" . . .... ...... ...... .. ...... .... .... ..... . ...... . .. ..... .. .. .... ...... . . . . ...... NOA No.: 13-1217.01 anoro naoEfiqUNWExpiration Date: 10/11/17 "'• ' Approval Date: 11/06/14 Page 6 of 33 APPROVED SURFACING: TABLE 4 Productroduct &Whication Manufactur _._ Specification Name "Crilmon Rate er PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1'/v-2 gal/sq TAS 140 Polyglass to add life and rejuvenate existing USA,Inc. BUR.roofing substrates. XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used 1'/Z-2 gal/sq TAS 140 Polyglass Coating to add life and rejuvenate existing USA,Inc. BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof 1'/Z-2 gal/sq ASTM D4479 Polyglass coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR XtraFlex Bituminous Roof An asphalt cutback fibered roof 1'/r2 gal/sq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. '/2-1 gal/sq ASTM D2824 Polyglass Roof Coating Type I USA,Inc. PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass Coating Type III USA,Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 ••Polyglass based roof coating(water-based). A • ••tJ6A,Inc'•••:• . . polyester fabric may be used for •• "'. : • reinforcement with this coating. • PG800 Non-Fibered Asphalt An asphalt base,un fibered clay 3 gal/sq in AW 401227 ..Polyglass" Emulsion Roof Coating emulsion two coats ••••' o•WA,Inc?•.... XtraFlex 80 Emulsion Roof An asphalt base,un fibered clay 3 gal/sq in AtW1l227:.: oiyglass,,,,,, S .• Coating emulsion two coats ...... u �Inc. PG850 Fibered Asphalt Emulsion An asphalt base,fibered clay 3 gal/sq in ASTM D1227:..Pblyglasg' Roof Coating emulsion two coats :• USA,Inch.... Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824'..Myglass Aluminum Roof Coating Type III USA,Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 116-2 gal/sq ASTM D2824 Polyglass Coating Fibered Type III USA,Inc. Polyplus 60 Premium Non Non-fibered aluminum roof coating. %a-1 gal/sq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA,Inc. XtraFlex 60 Aluminum Roof Non-fibered aluminum roof coating. '/z-1 gaUsq ASTM D2824 Polyglass Coating Type I USA,Inc. NOA No.: 13-1217.01 ML4hn�gpe COU Expiration Date: 10!11/17 ®""• ' Approval Date:11/06/14 Page 7 of 33 APPROVED SURFACING: TABLE 4 Product Product Application Manufactur Name Description Rate Specifleabton er Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1'/a gal/sq ASTM D6083 Polyglass Elastomeric Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/Z gal/sq ASTM D6083 Polyglass Roof Coating based roof coaxing(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. Pol�brite 90 High Solids Silicone A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coaxing Polybrite 95 Silicone hoof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. XtraFlex SRC 8000 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. Gravel To be installed in a flood coat of 400 lbs/sq NIA Generic approved asphalt at 60 lbs/sq '000000 To be installed in a flood coat of 300 lbs/sq .• •... • •,• Slag N1A Generic • approved asphalt at 60 lbs/sq ' ...... .. ...... .... .... . . ...... . .. ..... .. .. .... ...... ...... 9.6 . ... 00 0 NOA No.: 13-1217.01 M1AMF�ADECOUNTY Expiration Date: 10/11/17 Approval Date:11/06114 Page 8 of 33 EVIDENCE SUBMITTED: Test enc Test Name/Reuort Report No Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4.4.70 3001334 02.15.00 4470 3000857 01.12.00 4470 3004091 01.12.00 4 .70 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4.4.70 3014692 08.05.03 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-Ri 02.27.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164/ASTM D6222 P10490.08.08 08.13.08 ASTM D6164/ASTM D6222 P 10490.10.08-R1 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D)–ASTM D1876 P10070.10.08 14.09.08 ASTM D6222 P 10490.10.0$-2 .•. •10.6008 .... ;• FM 4470&TAS 114 P33970.03.11 ,15 •03 ,11 •• 00• ASTM D6163/ASTM D 4601 P33960.03.116 •• 03.15'11 TAS 114&TAS 117(B) 11757.12.00-1-Rj...• q j.L9.13 ..... TAS 114&TAS 117(B) 11757.04.01-1-IU...' •Q4v3.0-13 ASTM D6164 P37590.07.13-4..... .07X.13 •• ASTM D6164 P37590.03.13-346966 '0:W13 ...... ASTM D6163 P37590.03.13-2;R :—: 0245.13 ASTM D6222 P37590.09.13 ;Qg6t1„13 •••••• ASTM D4601/TAS 117 P45940.09.13 *09.04.13 TAS 114&FM 4474 P41630.08.13 •b8=13 ' TAS 114(Ii) P13760.09.09 09.10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 NOA No.: 13-1217.01 aue COUNTY Expiration Date: 10/11/17 '" • ' Approval Date:11/06/14 Page 9 of 33 Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32"or greater plywood or wood plank,fastened at 24"spans with 8d ring shank nails at 6" o.c.at edges and intermediate supports. System Type E(2): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Polyglass APP Base,Elastobase(Poly/Sand)sheet fastened to the deck as described below: Fastening: Attach base sheet using 11 ga.annular grooved shank and 1"diameter caps spaced 6"o.c.in a 3"lap and 6"o.c.in four equally spaced staggered center rows. Membrane: One ply of Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyfresko G SBS SA, Polyfresko G SBS SA FR,Polyflex SA P,Polyflex SA P FR,Xb%Flex APP G SA,Polyfresko � of or XtraFlex Kool APP S SA self-adhered. APP SA Pol Ko G APP SA,Polyfresko G � Y Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. •••• • • Maximum Design •••• •••••• Pressure: -52.5 psf;(See General Limitation#7) 0000.. 0000.. 0000 0000 . . 0000 0000 0000. 0000.. . .. ••••• .. .. 0000 9999.0 0000•• • • • • • • 9000•0 0000•• • • 9 • • • • • 0000•• 9• • NOA No.: 13-1217.01 tY11AIyanADECoUNTYIN Expiration Date: 10/11/17 NOW Approval Date:11/06/14 Page 27 of 33 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LiXffATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bsJsq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.;or strip mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F)value of 2751bf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 2751bf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requiremagt;Jthese a;*e�*as*Fastenb?' densities shall be increased for both insulation and base sheet as calculated in, lance witk?toofin ..�. Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida rgistered Professiogp Engineer, Registered Architect, or Registered Roof Consultant (When this limitat.i©a.� pecifioall�r eferrOd••• within this NOA,General Limitation#9 will not be applicable.) •••• *see ••••• 8. All attachment and sizing of perimeter hailers,metal profile,and/or flashing terminattd4 detgns st4 oepform t ep .. Roofing Application Standard RAS 111 and applicable wind load requirements. 0000 0600:0 9. The maximum designed pressure limitation listed shall be applicable to all roof pressVesox3�sas(i.e.field, perimeters,and comers).Neither rational analysis,nor extrapolation shall be permittgd fo.enhanced fastening if"' enhanced pressure zones(i.e.perimeters,extended corners and corners).(When this JjW talion is spe;j4cally;•••• referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-1217.01 rvahu ►s�cru Expiration Date: 10/11/17 '" • ' Approval Date:11/06/14 Page 33 of 33 I Ur U.M*+:)I 1 -tcoonng systems Page 1 of 11 a u1 ftNLINE CERTIFICATIONS DIRECTORY TGFU.R14571 Roofing Systems aae Bottom - - - - —- - - - Roofing Systems See General Information for Rooflno Systems POLYGLASS USA INC R14M 1111 W NEWPORT CENTER DR DEERFIELD BEACH,FL 33442-7732 USA SINGLE PLY MEMBRANE SYSTEMS Unless otherwise Indicated,the insulation and base sheet are mechanically fastened in piece;the membrane is heat welded in place. (Optional)Noncombustible deck classifications are applicable for use over combustible(15/32 In.min plywood)decks when 1/2 in.(min)gypsum board or 1/41n.(min)G-P Gypsum"DensDeck®Roofboard","DensDeck Prime®Roofboard","DensDeck DuraGuard^°Roofboard"or 1/4 in.(min) USG Corp SECUROCKTM Roof Board Type FRX-G are used directly over the combustible deck with all joints staggered 6 in.(min)from plywood joints. Unless otherwise indicated,in any noncombustible roof deck Classification any UL Classified Insulation may be utilized underneath a layer of 1/4 tn.(min)G-P Gypsum"DensDeck®Roofboard","DensDeck Prime®Roofboard","DensDeck DuraGuardTm Roofboard"or 1/4 in.(min)USG Corp SECUROCKTM Roof Board Type FRX-G. General statement for use of vapor retarders and/or deckAnsulatlon adhesives(NC decks only):When such vapor retarders or deck/insulation adhesives are acceptable to POLYGLASS they may be utilized. "POLYGLASS BASE,"MODIBASE","Polyglass G2 Base"may be used in lieu of any Type G2 base sheet In any NC Classification.These products may also be used in any C-15/32 Classification in which a generic Type G2 Is referenced(i.e.not brand specific)."POLYGLASS Ply 4", "POLYGLASS Ply 6"(Type GI),"POLYGLASS VENTED BASE","XtraFlex Ply IV","XtraFlex Ply VI"and"XtraFlex G2 Base"may be used In any NC Classification.These products may also be used in any C-15/32 Classification in which a generic Type GI is referenced(i.e.not brand specific). "BASE PRO"or"POLYFLEX SA BASE"may be used as an acceptable alternate of"ELASfOFLEX SA V"base sheet. References to polyisocyanurate Insulation may Include Polyglass Products"POLYTHERMW and"POLYTHERMO Tapered". . ••• • • 0000 0000•• Acceptable alternates to the membranes listed are given below: • • • • •• 0000•• Membrane Listed Acceptable Alternatives •••i•• • • • 0000•• "POLYBOND" "MODIBOND"or"Torch Pro Smooth" 4000 • • "POLYBOND G" "MODIBOND G"or"Torch Pro Granular" 604 •6:9•• • •• •0000 °ELASTOBASE" "Xtraflex HT 650 Base"or"Polyglass HT Base 650" •• •• :•• 9006:6 0000•• • • "Polytherm"."PoWerm Tapered"or"Poivtherm Composite"insulatlons may be used wharavar palyisoeyanurata insula;6 6 6%sp®e1fio�In 0 •••• • Classifications below. • • Insulation may be optional for any non-combustible deck roofing system unless the Insulation acts as a coverboard ove;4V&ler:lnsulatIop. .9 9 The"Cure Technology"finish may be added to any Polyglass membrane without adversely affecting the UL Classification for that •• • product/assembly.The product/assembly would maintain the same Classification with or without the"Cure Technology"process. SINGLE PLY MEMBRANE SYSTEMS Class A Class A-Ballasted 1.Deck:NC Incline:3 Insulation:—Dyplast Products LLC"Pyrox White Line,"glass fiber,partite or wood fiber,any thickness. Membrane:—Any UL Classified PVC,mechanically fastened. Surfacing:—"Polybrite 95 Silicone"or"XtraFlex SRC 8000"series applied 11/2-gal/100AV. 2.Deck:NC Incline. 1/2 Insulation,—Dyplast Products LLC"Pyrox White Line,"glass fiber,perllte or wood fiber,any thickness. Membrane:—Any UL Classified hypalon,mechanically fastened. Surfacing:—"Polybrite 95 Silicone;"XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or°XtraFlex SRC 9600"series applied at 1%-gal/100-fe. I/J–i_1-_- 1 I • 1 • I . T 1.-- . . —I - ... -- ._ 1'(i,t''U.1Z14571 - Roofing Systems Page 2 of 11 1.Deck:C-15/32 Inclines 3 Ply or Base Sheep—One ply"Polyanchor",mechanically fastened. Insulation:—Polyisocyanurate,urethane,pedite/polyisocyanurate composite,periite/urethane composite,glass fiber,phenolic or perilte,any thickness. Ply or Base Sheet:—One ply"ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX V°,"Xtraflex SBS Glass Interply", "ELASTOFLEX V-C","XtraFlex SBS G HP"or"ELASTOSHIELD TS G". Membrane:—One or more layers"DUFLEX",°DUFLEX G",°POLYGLASS 350 CAP","POLYFRESKO 350 CAP°,"POLYBOND°,"POLYBOND G","POLYFLEX","Xtraflex APP S","POLYFRESKO G","Xtraflex APP G°,"XtraFlex APP G HP TOR"or"POLYFLEX G"(modified bitumen), heat welded,or one or more layers'ELASTOFLEX V",IXtraflex SBS Glass Interpiy°,"ELASTOFLEX V-C","ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX S6","XtraFlex SBS POLY Base","ELASTOFLEX P-C","XtraFlex SBS G HP"or"ELASTOSHIELD TS G",mopped In hot asphalt or heat fused. Surfadng:—Gravel,embedded in hot mopping asphalt. Class B-Ballasted 1.Decks C-15/32 IInclines 3 Base Sheets—Type G2. Membrane:—"DUFLEX","DUFLEX G","POLYBOND","POLYGLASS 350 EAP","POLYFRESKO 350 CAP","POLYBOND G","POLYFLEX", "Xtraflex APP S",°POLYFRESKO G°,"POLYFLEX G","XtraFlex APP G HP TOW or"Xtraflex APP G"(modified bitumen),heat welded,or one or more layers"ELASTOFLEX V","Xtraflex SBS Glass Interpiy","ELASTOFLEX V-C","ELASTOBASE","XtraFlex SBS GLASS Base°, "ELASTOFLEX S6","XtraFlex 5B5 POLY Base","ELASTOFLEX P-C","XtraFlex SBS G HP"or"ELASTOSHIELD TS G",mopped in hot asphalt. Surfacing:—Gravel,embedded in hot mopping asphalt or heat fused. Class A-Fully Adhered 1.Deck NC Indine:1/2 Insulation(Optional):—Polyisocyanurate,urethane,periite/poiyisocyanurate composite,perlite/urethane composite,glass fiber, phenolic or perlite,any thickness. Base Sheet:—One or more layers"ELASTOBASE",-XtraFlex SBS GLASS Base","POLYFLEX",'Xtraflex APP S","ELASTOFLEX V", "Xtraflex SBS Glass Interply",°ELASTOFLEX V-C"or Type G2 base sheet. Membrane:—"POLYBOND","POLYBOND G","POLYFLEX","Xtraflex APP S°,°POLYFRESKO G",OXtraflex APP G","XtraFlex APP G HP TOR" or"POLYFLEX G"(modified bitumen),heat welded. Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Kokem Products"Sunguard Acrylic Roof Coating"at 1 gal/sq;or Karnak No.97 Flbrated Aluminum Asphalt Roof Coating or Karnak No.97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by"PolyPlus 60",applied at 3A-1 gal./sq.. 2.Deck C-15/32 Incnne:1/2 Insulation:—Two or more layers(insulation joints staggered a min of 6 in.from plywood deck joints)poiyisocyanurate, periite/polylsocyanurate composite,perlite/urethane composite,glass fiber,phenolic or perlite,any thickness. Base Sheetr—One or more layers"ELASTOBASE"j"XtraFlex SBS GLASS Base",'POLYFLEX","Xtraflex APP S","ELASTOFLEX V",•••• 'Xtraflex SBS Glass Interply","ELASTOFLEX V-C°or Type G2 base sheet. • • Membrane:—"POLYBOND","POLYBOND G","POLYFLEX","Xtraflex APP S","POLYFRESKO G","Xtraflex APP Gay"XtsaFlex APP GSiP TOR" • i• or"POLYFLEX G°(modified bitumen),heat welded. •• • ••• • • Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Kokem Products"Sunguard AarK icAoof Coating"at i•: •.••:. gal/sq;or Karnak No.97 Flbrated Aluminum Asphalt Roof Coating or Karnak No.97 Asbestos Free Aluminum Rgce Vg at 1 to 2%al/ • • sq;or Brewer Tortrew 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by"PolyPlus 60°,applied at 3/4-1 gasq..Soso 0006 •••• 3.Deck C-15/32 Indine:1/2 •••••0 •••••0 •.••• • • •••••• • •• ••••• Insulation:—1/4 In.thick G-P Gypsum DensDeck®,perlite,wood fiber or glass fiber,1 in.,mechanically fastened. • • • • Base or Pty Sheet:—One or more layers"POLYFLEX*or"Xtraflex APP S"(mechanically fastened or heat weldeb),btl ASTOBASE •• ••••;• "XtraFlex SBS GLASS Base","ELASTOFLEX V",'Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 bar* eto(mechanicall9 •• fastened or hot mopped). Membrane:—"POLYBOND","POLYBOND G",°POLYFLW,'Xtraflex APP S","POLYFRESKO G","Xtraflex APP G","XtraFiex APP 6d tP• • ••• TOR",or"POLYFLEX G°(modified bitumen),heat welded or hot mopped. • • • • • Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Monsey Products"Endure Aluminum Rvof Coating",*•• : ••• "Weather Check°or"Pro-Grade Aluminum Roof Coating",1.5 gal/sq;or Karnak No.97 Fibrated Aluminum Asphalt Roof Coating qr jdm:k No.97 Asbestos Free AlUffi fiUM Rbof Coating at 1 to 2 gel/t4f;Or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal.1sq., followed by"PolyPlus 60",applied at BA-1 gal./sq.. 4.Deck:NC Inclines 1 Insulation(Optional):—Polyisocyanurate,glass fiber,perlite,wood fiber,any combination,any thickness. Base Sheen—"POLYFLEX"or"Xtraflex APP S"(mechanically fastened or heat welded)or Type G2,mechanically fastened or hot mopped. Membrane:—"POLYBOND","POLYBOND G","POLYFLEX","Xtraflex APP S",°POLYFRESKO G","Xtraflex APP G","XtraFlex APP G HP TOR" or"POLYFLEX G"(modified bitumen),heat welded. Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Grundy Industries"al MB Aluminum Roof Coating"at 1-2 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by"PolyPlus 60",applied at 3/4-1 gal./sq.. S.Deck:NC Indine:1 Insulation(Optional):—Poiyisocyanurate,urethane,periite/poiyisocyanurate composite,partite/urethane composite,glass fiber, phenolic,perlite or wood fiberboard,any thickness. Illase Sheet!—One or more layers"DUR.EX"or"POLYFLEX"or"Xtrafiex APP S"(heat fused or mechanically fastened),"ELASTOBASE", "XtraMex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interpiy","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped, heat fused or mechanically fastened). ___ __I __---L_: 7.!. Rrvrfr J, t.. /T Tf/TNt 11 TT n 1 1 . ,.....,.. — '!`UFUR14571 -Roofing Systems Page 3 of 11 Membrane.—"DUFLEX G FR","XtraFlex APP Dual","POLYFRESKO G FR",'Xtraflex APP G FR" "XtraFlex APP G HP'or"POLYFLEX G FR"(modified bitumen),heat fused. ' 6.Deck:C-15/32 Incline: 1/2 Base Sheet:—One or more layers"DUFLEX°or"POLYFLEX"or"Xtraflex APP S"or"POLYGLASS Base"(heat fused or mechanically fastened),"ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped,heat fused or mechanically fastened). Ply Sheet:—One or more layers"DUFLEX"or"POLYFLEX"or"Xtraflex APP S°or"POLYGLASS Base"(heat fused)or"POLYGLASS Base", °ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraftex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet (hot mopped)or mechanically attached. Membrane:—"DUFLEX G FR","XtraFlex APP Dual","POLYFRESKO G FR","Xtraflex APP G FR","XtraMex APP G HP"or"POLYFLEX G FR"(modified bitumen),heat fused. 7.Deck;C-15/32 Incline:1/2 Insulation:—Polyisocyanurate(2 In,min),perlite(3/4 in.min),glass fiber(7/16 in.min),perlite/polylsocyanurate composite, periite/ureMane composite(2 In.min)or(2 in.min)polylsocyanurate covered with 1/2 in.perilte or wood fiberboard. Base Sheet;—One or more layers"DUFLEX"or°POLYFLEX"or"Xtraflex APP S°(heat fused or mechanically fastened),"ELASTOBASE", °XtraFlex SBS GLASS Base","ELASTOFLEX V°,°Xtraflex SBS Glass Interply","ELASTOFLEX V-C'(heat fused,mechanically fastened or hot mopped)or Type G2 base sheet(hot mopped or mechanically fastened). Ply Sheet:—One or more layers'DUFLEX'or"POLYFLEX"or"Xtraflex APP S"(heat fused)"ELASTOBASE","XtraFlex SBS GLASS Base", ELASTOFLEX V","Xtraflex SBS Glass Interply",°ELASi'OFLEX V-C"or Type G2 base sheet(hot mopped)or mechanically fastened. Membrane:—'DUFLEX G FR","XtraFlex APP Dual",°POLYFRESKO G FR","Xtraflex APP G FR","XtraFlex APP G HP"or"POLYFLEX G FR"(modified bitumen),heat fused. 8.Deck:NC Incline:1/2 Insulation(Optionans—Polylsoryyanurate,urethane,perlite/polylsocyanurate composite,perlite/urethane composite,glass fiber or wood fiberboard,phenolic or perlite,any thlcimess. Base Sheet:—One or more layers"DUFLEX*or"POLYFLEC°or"Xtraflex APP S"(heat fused or mechanically fastened),°ELASTO8ASE°, "XtraFlex SBS GLASS Base","ELASTOFLEX V°,"Xtraflex SBS Glass Interpiy","ELASTOFLEX V-C"(hot mopped,mechanically fastened or heat fused)or Type G2 base sheet(hot mopped or mechanically fastened). Membranes—"ELASTOFLEX VG FR","ELASTOSHIELD TS G FR","ELASTOFLEX S6 G FR","Xb-aFlex SBS POLY G","XtraFlex SBS POLY G TO,"XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or"POLYFRESKO G SBS FR"(modified bitumen),hot mopped or heat fused. 9.Deck:C-15/32 Incline:1/2 Base Sheet:—One or more layers'DUFLEX"or"POLYFLEX°or"Xtraflex APP S°(heat fused or mechanically fastened),"ELASTOBASE", "Xb%Fldk SBS GLASS Use","ELASiOFLEX V","Xfreflek SBS G%ss Interpiy"or Type G2 base sheet(hot mopped or mechanically fastened). Ply Sheet:—One or more layers"DUFLEX"or"POLYFLEX"or'Xtraflex APP S°(heat fused),"ELASTOBASE","XtraFlex SBS GLASS Base", "ELASTOFLEX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped or mechanically attached). Membrane.——'ELASTOFLEX VG FR","ELASTOFLEX S6 G FR',"POLYFRESKO G SBS FR","XtraFlex SBS POLY G°,"XtraFlex SBS POLY G TO,°XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or"ELASTOSHIELD TS G FR°(modified bitumen),hot mopped or heat Nfet.``. • • •••••• 10.Deck:C-15/32 Incline:1/2 •do• 0 *:•••••• •• Insulations—Polylsocyanurate(2 in.min),perilte(3/4 in.min),glass fiber(15/16 in.min),periite/polyisocy$nljliLteomposite, •• •""` perilte/urethane composite(2 in.min). 000000 . • Base Sheet:—One or more layers"DUPLEX°or"POLYFL.EX°or"Xtraflex APP S"(heat fused or mechanically fastwvQ,"ELASTOJ"W, XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C'or Type G2 ba%jVgr(hot md�pp j�o mechanically fastened). ••••• Pry Sheet:—One or more layers"DUFLEX"or"POLYFLEX"or"Xtraflex APP S°(heat fused),"ELASTOBASE",u)M V1W IBS GLASS 0&; ••••• "ELASTOFLEX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped or meftnlsally attached}••• .••••• Membrane:—"ELASTOFLEX VG FR","ELASTOFLEX S6 G FR°,"POLYFRESKO G SBS FR°,"XtraFlex SBS POLY q-,.V ilex SBS POLE'G •• T","XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"or"ELASTOSHIELD T5 G FR"(modified bitumen),hot Wopp$d or heat fused. • 11.Deck NC Incline:1 • •` :•••i• :•••• Insulation(Optional):—Cellular concrete,gypsum concrete,vermiculite concrete,perlite concrete or structuralconcrete. •• V: Primers—Not UL Classified—as required by manufacturer. •• • Membrane:—"POLYBOND","POLYBOND G","POLYFLEX",'Xtraflex APP S","POLYFLEX G","XtraFlex APP G HP TOR","Xtraflex APP G", "Xtraflex APP G FR","POLYFRESKO G FR","POLYFLEX°,"Xtraflex APP S","POLYFLEX G",'XtraFlex APP G HP TOR","DUFLEX G FR", "XtraFlex APP Dual","Xtraflex APP G FR","XtraFlex APP G HP"or"POLYFLEX G FR". Surfacings—(net required for"POLYFLEX G FR","XtreFlex APP G HP","XtraFlex APP Dual","Xtraflex APP G FR","POLYFRESKO G FR"or "DUFLEX G FR")"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Monsey Products"Endure Aluminum Roof Coating",at 1.5 gal/sq;or Grundy Industries"al MB Aluminum Roof Coating",at 1-2 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by°PolyPlus 601,applied at 9/a-1 gal./sq. 12.Deck NC Incline:1 Insulation(Optional):—Any thickness,one or more layers UL Classified perlite,wood fiber,glass fiber,polylsocyanurate, polylsocyanurate/composite,EPS/wood fiber,EPS/perilte or EPS/composite. 1138fild SWUM—One 3f MOFe leyer'e Typ@ G1 OF G2. Membrane:—One or more layers"POLYBOND","POLYBOND G","POLYFLEX","Xtraflex APP S","Xtraflex APP G","XtraFlex APP G HP TOR",or"POLYFLEX G"(modified bitumen),heat fused. Surfacing*—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Fields"F350 Heat Shield Aluminum Coating"or"F630 Heat Shield Fibered Aluminum Coating",1-1/2 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by "PolyPlus 60",applied at 3A-1 gal./sq. 13.Deck NC Incline:1/2 IrTOVIV—r/lL`DAAAL'/ t,.._.. _ 1.+...>n.. ._T r_ 1MPin Ir 1'(arr'U.X14Y/i -Rootmg Systems Page 4 of 11 Barrier Board(Optional))—1/2 In.gypsum board. Insulation(Optional):—Polyisocyanurate,any thickness. Base Sheet(Optional):—Type G2,"DUFLEX",°ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX V",°Xtraflex SBS Glass Interply",°ELASTOFLEX V-C","Xtraflex APP S"or"POLYFLEX". Membrane:—"ELASi'OFLE)(VG FR "POLYFLEX G FR","XtraFlex APP G HP","Xtraflex APP G FR","POLYFRESKO G FR",°DUFLEX G FR", "XtraFlex APP Dual","XtraFlex SBS GLASS G","XtraFlex SBS GLASS GT"(heat fused),'ELASTOFLEX S6 G FR°,"POLYFRESKO G SBS FRO(hot mopped)or"ELASTOSHIELD TS G FR"(heat fused or hot mopped). 14.Deck:C-15/32 Incline;1 Insulation:—1/4 in.thick G-P Gypsum DensDeck®,periite,wood fiber or glass Fiber,i in.,mechanically fastened. Ply Sheet:—Type G2,mechanically fastened. Membrane:—"POLYBOND","POLYFLEX"or"Xtraflex APP S"(modifid bitumen),heat welded. Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gat/sq.or Monsey Products"Endure Aluminum Roof Coating", "Weather Check"or"Pro-Grade Aluminum Roof Coating", 1.5 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq., followed by"PolyPlus 60",applied at 114-1 gal./sq. 15.iDecic NC Incline:1/2 Insulation(Optional):—Polyisocyanurate,periite,glass fiber or wood fiberboard,any thickness. Base Sheet:—On ply Type G2,hot mopped or mechanically fastened or"ELASTOBASE°,"XtraFlex SBS GLASS Base",heat fused,hot moppee Of rnwh2tUcaliy f55tenati. Membrane:—"ELASTOFLEX S6 G FR","POLYFRESKO G SBS FFV,"XtraFlex SBS POLY G°,"XtraFlex SBS POLY GP,"XtraFlex SBS G HP"or°ELASTOSHIELD TS G FR"hot mopped or heat fused. 16.Deck:C-15/32 Incline:1/2 Base Sheet:—One ply Type G2 or"ELASTOBASE","XtraFlex SBS GLASS Base",mechanically fastened. Ply Sheet:—One ply Type G2(hot mopped or mechanically fastened)'XtraFlex SBS GLASS Base"or"ELASTOBASE"(hot mopped,heat fused or mechanically fastened), Insulation(Optional):—Polyisocyanurate,perlite,glass fiber,any thickness. Membrane:—"ELASTOFLEX S6 G FR","POLYFRESKO G SBS FR",'XtraFlex SBS POLY G","XtraFlex SBS POLY G TO or ELASTOSHIELD TS G FR"hot mopped or heat fused. ' 17.Deck C-15/32 Incline:1/2 Insulation:—Polyisocyanurate(2 In.min),glass fiber(15/16 In.min),perlite/polyisocyanurate composite,perlite/urethane composite (2 in.min). Basoe Shebti—One or more layers"6UFL6O,')(traflex APP§"or°POLYFLEX°(heat fused or mechanically fastened),"ELASTOBASE°, 'XtraFlex SBS GLASS Base","ELASTOFLEX V",'Xtraflex SBS Glass Interply","ELASTOFLEX V-C°(hot mopped or heat fused)or Type G2 base sheet(hot mopped or mechanically fastened). ft Sheet(Optional):—one or more layers"DUFLEX",°Xtraflex APP S"or"POLYFLEX"(heat fused),"ELASTOBASE","XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interpiy","ELASTOFLEX V-C"(hot mopped or heat fused)or Type G2 base sheet(hot mopped or mechanically fastened). Membrane:—"DUFL.EX G FR",'XtraFlex APP Dual","POLYFRESKO G FR",'Xtraflex APP G FRO,"XtraFlex APP G HP"or"POLYFI,� V• FRO(modified bitumen),heat fused. • • • 4141.• 4141•••• 18.Deck:C-15/32 Inclines 1/2 •0 6 ••• • • 6416•409 6• •641.41• (nsulatio�i—Pelylsocyanurate(2 in:min);glass fiber(15/16 In.min),perilte/polylsocyanurate cofnp:Bite,p8fl /1i#Lff}ane composite %0041: 000* Base Sheep—One or more layers"DUFLEX","Xtraflex APP S°or"POLYFLEX"(heat fused or mechanically faslened]VL.ASTOI1 41 410:00" 6 "XtraFlex SSS GLASS Base","ELASTOFLEX V","Xtraflex SBS GIM Ifi%fply"be Type G2 base sheet(hot mopped of hredranicaliy 0 ss fastened)' 0664100 • •• 40641•• Ply Sheet(Optional):—One or more layers°DUFLEX","`Xtraflex APP S°or°POLYFLEX°(heat fused),"ELASTQQ$E;V6"XtraFI&. 6•• 000000 GLASS Bag%°,-ELASTOFLEX V°,°XtmfleX SBS Glass Interply",ILA&OPLE X V-C"or Type G2 base sheet(hot Tffil gr mechanicayy • fastened). 6 Membranes—"ELASTORZX 56 G","6LAST0FLDr 96 G-C"or'POLYFRESKO G SB3"(modrfled drwmen),not rAopped.• • 6 0906:9 •6.4141• 19.®eels C-15/32 Incline:1 6 6 6 ' • • • . ••41••6 4141 6 41 6.41 • • Insulation:—1/4 in.thick G-P Gypsum DensDeck® 6 6 41 / YP ,perlite,wood fiber or glass fiber,1 in.,mechanically fastened. •• • Ply Sheets—Type G2,mechanically fastened. Membrane:—"POLYFLEX"or"Xtraflex APP S"heat welded. Surfacing:—Monsey Products"Endure Aluminum Roof Coating","Weather Check"or"Pro-Grade Aluminum Roof Coating",1.5 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by"PolyPlus 60",applied at%-1 gal./sq. 20.Deck C-15/32 Incline:2-1/2 Barrier Board:—1/4 In.(min)G-P Gypsum DenSDecit(g with all joints staggered 6 in.from the plywood joints. Base Sheet:—Type G2,mechanically fastened. �p Membrane:—"POLYFLEX G FRO,"XtraFlex APP G HP","Xtraflex APP G FRO or"POLYFRESKO G FFV,heat fused in place. 21.Deck C-15/32 Incline:2 Insulation(Optional).—Polyisocyanurate,perlite,wood Aber or polyisocyanurate/perlite board,any thickness. Barrier Board:—1/4 in.(min)G-P Gypsum DensDeck@,mechanically fastened with all joints staggered 6 in.from the plywood joints. Base Sheets—"EIASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),mechanically fastened or"ELASTOFLEX SA V PLUS FFV, "ELASTOFLEX SA V FRI or ELASTOFLEX S V FR BASE VENT"(self adhered). Ply Sheet(ryO�ptional)i—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),heat fused or mechanically fastened,or"EL.ASTOFLEX SA V PLUS FRO,"ELASMI'LEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT",(Self adhered). "ELASTOFLEX SA V FI HST'",(self adhered)or OLOYFLE X G W,"XtraFiexx APPPFG HP","Xtraflex APP G FFRR,"POLYFRESKO G SBS SA p "FR","DUFLE( httt)://data.hal.-;e.iil.Cpm/e,ai-hinfXW/tPmnlFR AAMolirvus orva lifer l%^. a—rrr_ 1 in/,,n,c WMA1011 -KOOMg SIStemS Page 5 of 11 G FR',°XtraFlex APP Dear,°6 ASTOFLEX S6 G Flt-,-POLYFRESKO G SBS FR",-E3ASTOFL VG FR°,°Xtraflex SBS POLY G","Xtranex SBS POLY 0r,°ktraftx SM GLASS G","X4 aflex SBS GLASS Gr or°ELASTOSWELI)TS G FR',heat fused. 22.Decic C-15/32 Incline:1/2 Insulation(optional):—Poly! yanunats 1.5 In.(min.)with all joints staggered 6-In.(min.)from the plywood joints. Base Sheets—Type G2,mechanically fastened followed by°ELASTOBAW,°XtraFlex SBS GLASS Basel,mechanically fastened. Ply Slift(Optional):—"ELASTQFLEX SA V PLUS Rt° °ELASTOR EX SA V FR'or°iS�FLEXX SA l V FR BASE ViSVT' � ,(Self iadhi3r2d). Membrane:—°POLYFLEX SA P FR","POLYFRESKO ° ■ " ° G APP SA P FFV, SA P Rt POLYFRESKO G SBS SA P Rt or°DUFTFX G FR" °XftFlex APP Dual",°POLYFLEX G FR° °Xtrai l APP G HP" " " " ex '�(haHex APP G FR °ELAS'TOFLEX S6 G FR "POLYFRESKO GBS " , YFRESKO S AV, dJ45T'ORF�f VG FFV,'XtraFlex SBS POLY G',"XtraRex SBS POLY G T','XtraFlex SBS GLASS G-,'XtraRex SBS GLASS GT'or "ELASTOSHIELD TS G Rt°,heat fused. 23.Deck NC Incline:2 Insulation(Optional):—Atlas Roofing"ACFoam III"or"ACFoarn II'or Hunter Panels°H-Shield",any thickness. Base Sheet—"ELASTOBASE°,'Xtraftex SBS GLASS Base"(poly/sand),heat fused or mechanically famed or'FIASTOFLEX SA V FR!, "ELASTOFIEX SA V PLUS Rt"ar'ELASTOFLEX SA V FR BASE VENT",(semadh ). Membrarm:—°POLYFL EX SA P FR","PO cOG-APP 5A P FR",'MASTOFLEX SA P FR,*POLYFRESKO G SBS SA P FR°, °ELASTOFLE(SA V FR HT",(self adhered)or°POLYFLE(G FR°,'XUaFtex APP G HP°,°XUafiex APP G fit","POLYFRESKO G FR°,°XtraFlex APP Dual','DUFLEX G FR°,°E1J STOFM S6 G FR!,°FOLYFRESKO G SBS FR","ELASTORB(VG FR°,°XbaFiex SBS POLY G°,°XtraFlex SBS POLY G T","XtraFtex SBS GLASS G°,"Xtrafiex SBS GLASS Gi"or°ELASTOSHIELD TS G FR",heat fwd. 24.Deck C-15/32 - Incline:3 Insulation(Optional):—Polylsocyanurate,partite,wood fiber or polyisocyanurate/peri to board,any thickness. Barrier Board:—1/4 In.(min)G-P Gypsum Dw*De&*,mechanically famed with all joints staggered 6 in.from the plywood joints. Dam ShedU "ELASToW-SE","xtrarlex SBs GLASS 136W(poly/sem),rnecrianteeliy fastermuL Ply Sheet(Optional):—°O.ASTOFLEX SA V PLUS FRO,9R ASTOPLEX SA V Flt"or°Ei.ASPOFL.EX SA V FR BASE Vi34T°,(self adhered). Membrane:—°ELASTORBC S6 G FR",'XtraFlex SBS POLY G°,'xtreFlex SBS POLY G T°or"POLYFRESKO G SBS FFV,heat fused. 25.Declu NC Incline:3 In.vnlation(Optional):—Atlas Roofing"ACFoam III°or"ACFoam II"or Hunter Panels"H-Shleld%any thickness. 8 Base SIiQ�—"B.ASTOFi�X SA V PLUS FIX",°ELAST01�(SA V FR or°ELASl'QFLEX SA V FR BASE VEIiT°(self adhered). M — or"M YFL,C SA PFR", M ' LYFRC-SKB G M'SA P FR",'� ii SFl.M(SA F FR' LYFR6K0 G SBS SA F FR"(self adhered). 26.Dedc NC Incline:112 Base Sheeb—Type G1 or G2,mechanically fastened. Membrane:—"POLYFLEX G","XtraRex APP G HP TDR",°Xtraflex APP G°or°POLYBOND G",heat fused. 27.Deft NC Incltne:9 Membrane:—°POLYRM SA-P Rt°,"POLYFRESKO 0 APP SA P FR",°POi:YFRESKO G SW SA P fWor'ELASTOFLBK SA R FR°ow?••••• •••••• adhered). • • • • 28.Deeks NC Incline:1 •••••• •• •••••• • Imuiati n(optimal):—Polytsocyanurate,any thickness. •••••• Save street(Optional):—'ELASTOFLEX SA V","ELAS OFLE(SA V PLUS',"Xtrdfiex SBS Base sA"or TLASTOFi&sf►O BASE•• • self-adhered or`ELAVrOBd�°,"XtraFlex GLASS Base(Poly/sand),mechanically *see •• f• ••••• Membrane:—°POLYFLEX SA P","Xtrafiex APP G SAO°XtraRex Kool APP G SA' or"POLYFReSKO G APP ••:••• , SA P°salf+a111ner'sd or"Pf9LYFdBC G F;V,hdat fitted, •••• 0.:. .* • •• •••••• • 29.Decic C-15132 Incline:1/2 +• •: • •+ • • • •••••• Insulation:—Potylsocyanurate(21n.min),glass fiber(15/16 in.min),periite(polyisocyanurate composite,peril�/uretl►ane • •• • (2In.min)• • • • •••••• Banter Board,—1/4 in.(min)G-P Gypsum DensDeck®,mechanically fastened,with 6 in.offset to plywood joint'!.• • .• :0: • • Base gent+—°ELASTOFLE(S6-,`XIoViex SBS POLY Base-,-EL ASTDFLEX P-C"(heat fused or mechanically fastened). •• • Membrane:—"ELASTOFLEX S6 G",°ELASMFLEX S6 G-C'or"POLYFRESKO G SBS",(heat fused). 30.Deck NC Incline:1/2 insulation(optional)—Atlas Roofing'ACFoam III"or"ACFoam II°,any thickness. Base Sheet:—°ELASTOFLE(SA V-PLUS FW,°ELASTOFLJEX SA V fit'or°ELASTOFLEX SA V FR BASE VENT,(self adhered). Membrane:—°POLYKOOL SA'or°Xtral(ool APP S SA',(self adhered). 31.Deck 5/32 Incline:1/2 Base Sheep—G2 Base sheet mechanically fastened followed by-B.ASTOFLIX SA V PLUS Rt°,"E ASTOFLEX SA V FR"or"ELASTOFLE X SA V PR BASE VENT",(self adhered). Membrane:—"POLYKOOL SA'or'XtraKool APP S SA',(Self adhered). 32.Dodo NC UtcHae:1/2 insulation(Optional):—Polyisocyanurate,any thlekdess. Base Sheet(Optional):—OEMIDFLE X SA V PLUS°,°Xtrafiex SBS Base SIV,9H ASMFLE(SA V°or 9H ASTOFIEX SA V BASE VENT", self-adhered or"ELASTOBASE",°Xtraf ex SBS GLASS Base'(Poly/send),mechanically fastened. Membrane:—"B.ASTOFL.EX S6 G',°ELASTOFLE(S6 G-G°or-POLYFRESKO G SBS',heat fused. httn-11Aafuhaep nT ithm/ei i-hilnf i' V/tAn-it"Ihto/1711QV 1I RV AAAP faliniimanA htmI rw�—T13 1!7/'}!114 1 UP U.-KI 4')'/1 -Kooimg Systems Page 6 of 11 33.Deck NC Incline:1-1/4 Insulation(Optional):—Any UL Classifled Isocyanate or polyurethane,any thickness. Base sheet:—"ELASTOFLEX SA V PLUS FR","ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT",self adhered. Membrane:—"POLYKDOL SA"or"XtraKool APP S SA",self adhered. 34.Deck NC Incline:1 Insulation(Optional):—Any UL Ciassifled polyisocyanate,any thiclMess. Base Sheep—'ELASTOFLEX SA V PLUS FR","ELASTOFLEX SA V FR"or"ELASTOFLEX SA V FR BASE VENT" self adhered. Membrane:——"POLYBIANKO APP SAP",self adhered. ' 35.Dela NC Incline:1/2 Insulation(Optional):—Polyisocyanurate,glass fiber,perllte or wood fiberboard any thickness,any combination,mechanically fastened or hot mopped In place. Base Sheet:—Type G2,"ELASTOBASE","XtraFlex SSS GLASS @ase"/"MODIBASE"or"ELASTOFLEX V","Xtraflex SBS GIag3 Intcr�ty", mechanically fastened. Ply sheet(Optional):—Type G2,"ELASrOBASE","XtraFlex SBS GLASS Base',"MODIBASE°or°ELASTOFLEX V","Xtraflex SBS Glass Interply "ELASTOFLEX S6°,°XtraFlex 5Br POLY Base";"POLYFLEX°,"Xtraflex APP S°aP"DUFLEX"adhered With Volypius 3�","pG350", °XtraFlex Cold Applied Mod Bit Adhesive"or Alco Products"SBS Modified Bitumen Adhesive No.269"at 1 to 1-1/2 gal/sq. Membrane:— D "ELASTOFLEX G S6 FR","POLYFLD(G FR",-XtraFlex APP G HP","Xtraflex APP G FR"(sand-backed)"XtraFlex APP Dual"or UFL€X G FR"(sand-backed),adhered with"Polyplus 35","PG350°,Wbi'lex Cold Applied plod"Bit Adhesive"or RICO Products"SBS Modified Bitumen Adhesive No.269"at 1 to 1-1/2 gai/sq. 36.Deck C"15/32 Incline:1/2 Insulation(Optional):—Polyisocyanurate(1.3 in,min),glass fiber(7/16 in.min)or perlite(3/4 in,min),mechanically fastened or hot ff OP06d in place. Base Shem—Two plies Type G2,first ply mechanically fastened and the second ply fully adhered with"Polyplus 35","PG350", "XtraFlex Cold Applied Mod Bit Adhesive"or Alco Products"SBS Modified Bitumen Adhesive No.269"at 1 to 1.1(2 gal sq. Mlembrane:—"ELASTOFLEX G S6 FR","POLYFLEX G FR","XtraFlex APP G HP","Xtraflex APP G FR"(sando 1/2),adhered with "Polyplus 35","PG350","XtraPlex Cold Applied Mod Bit Adhesive"or Alco Products"SBS Modified Bitumen Adhesive No.eyed i 1 to 1-1/2 gal/sq. 269" 37.Decla C-15/32 Incline:1/2 Barrier Board:—1/4 in.(min)G-P Gypsum DensDeck®,mechanically fastened with all joints staggered 61n.from the plywood joints. Insulation(Optional):—Polyisocyanurate,glass fiber,wood fiberboard,any thickness,mechanically fastened. Base.sheet:—Type G2,one or more plies,mechanically fastened. Ply sheet(Optional):—Type G2,"ELASTOBASE",'XtraFlex SBS GLASS Base° "ELASTOFLEX V","Xtraflex SBS Glass Interply", "POLYFLEX°,"Xtraflex APP S°or"DUFLEX°(sand-backed)adhered with"Polyplus 35","PG350","XtraFlex Cold Applied Mod Bit Adhesive" or Alco Products"SBS Modified Bitumen Adhesive No.269"at i to 1-1/2 gal/sq. Membrane:—"ELASTOFLEX G S6 FR","POLYFLEX G FR",'XtraFlex APP G HP",°Xtraflex APP G FRO(sand-backed)"XtreFlex APP Dual'or DUFLEX G FR"(sand-backed),adhered with"Polyplus 35","PG350","XtraFlex Cold Applied Mod Bit Adhesive"or Alco Products"SBS Modified Bitumen Adhesive No.269"at 1 to 1-1/2 gal/sq. 38.DWIC NC •••• Incline:1/2 • • • • •••••• Insulation(Optional) •• • .::00. • any thickness or polystyrene:—Polyisocyanurate,polyisocyanurate/periite composite,glass fiber,perlite or wood flbar{aw4 any combinatimr, •••• • wood fiberboard,mechanicallynfastened thichness covered with�/a in,perlite,1/4 in.(min)G-P Gypsum DensDeck®,7/jg V.81iss fiber or L,in. Base Sheet:—°Type G2,TLASTOFEX V",adhered with"Polyplus 351,"PG350","XtraFlex Cold Applied Mod BItkandma"or Alco* ••• i••••' Products"SBS Modified Bitumen Adhesive No.269"at i to 1-1/2 gal/sq. Membrane.—"ELASTOf1EX G S6 FR","POLYFLEX G FR","XtraFlex APP G HP","Xtraflex APP G FRO sand-backe�1� •• 0000 ••••• DUFLEX G FRO(sand-backed),adhered with"Polyplus 35","PG350","XtraFlex Cold Applied Mod Bit Adhesive"oroca Propucts"FAex BSO �0 •••••• Modified Bitumen Adhesive No.269"at 1 to 1-1/2 gal/sq. •• •• •••• •••••• • 39.Deck:C-15/32 Incline:1/2 • • • • • • • • •••••• Base Sheet:—Type G2,mechanically fastened. • • e • • Ply Sheol"—Type G2,hot mopped. • • • •••••• Membrane:—"TPOFLEX G FR",heat fused. •• • • ••• • • 40.Deck C-15/32 Incline:1 Base Sheet:—Type G2,mechanically fastened. Ply Sheet:--"DUFLEX",hot mopped. Membrane:——"TPOFLEX G FR",heat fused. 41.Deck:C-15/32 Incline. 1/2 Insulation:—Polyisocyanurate,perlite,wood fiber or polyisocyanurate/pedite,any thickness. Base Sheep—"POLYFL EX"or"Xtraflex APP S",hot mopped. Membrane:—"TPOFL.EX G FR",flat fU"sea. 42.Deck:NC Incline:3 Insulation(OPtiomi):—Any UL Classified Polyisocyanurate,any thickness,mechanically fastened. Base Sheet:— Elastoftex SA V FR Base",(self adhered). Membrane:—"Polykool SA R"or"Polyreflect",(self adhered). httD://database.ul.com/cgi-binfXYV/tPmnlntp./I.TCFXT/TF1?AAS/�t,,,.,„..,,,e t,.,-,t�;._,__•rr, , ,,,,,,,, I tit'U..x145'/1 -Koobng Systems Page 7 of 11 43.Decie C-15/32 Incline:1-1/2 Base Sheep—Type G2 Base sheet,mechanically fastened Ply Sheet:—"Elastoflex SA V FR Base",(self adhered). Membrane:—"Polykool SA R"or"Polyreflect",(self adhered). 44.Deck C-15/32 Inclines 1/2 Insulation:—Polylsocyanurate(2 in.min),glass fiber(15/16 In.min),perlite/polylsocyanurate composite,perllte/urethane composite (2 in.min). Base Sheet:—One or more layers"DUFLEX","Xtraflex APP S°or"POLYFLEX"(heat fused or mechanically fastened),"ELASTOBASE", 'XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interply"or Type G2 base sheet(hot mopped or mechanically fastened). Ply Sheet(Optional):—One or more layer:"DUPLEX","XtrafiV APP S"or"POLYFLEX°(heat fused),°ELA5TOBASE",'XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped or mechanically fastened). M+embiran a:—"PoWex G FR","Xtf"aFlex APP G HP",Pleat fused. 45.Devic C-15/32 Incline:1/2 Barrier Board:—1/2 in.(min)gypsum board or 1/4 In.(min)G-P Gypsum"DensDeck®Roofboard","DensDeck Prime@ Roofboard", °DensDeck DuraGuardTM Roofboard"or ya In.(min)USG Corp"SECUROCKTM Roof Board Type FRX-G"are used directly over the combustible deck with all joints staggered 6 in.(min)from plywood joints. Base Sheet(Optlonal):—Type G2 Base sheet,mechanically fastened. Ply Sheep—"Eiastoflex SA V FR Base",(self adhered). Membrane:—"Polykool SA R"or"Polyreflect",(self adhered). 46,Deckr NC Incline: 1/2 Insulation(Optional):—Polyisocyanurate,glass fiber,perlite/polylsocyanurate composite,perilte/urethane composite,any thickness. Bare Sheet:—One Or more IayeFa"DUFLEX","Xtrtflex APP S"or"PBLYFMI(heat fused or mechanically fastened),ti-ASTomse, "XtraFlex SBS GLASS Base","ELASTOFLEX V","Xtraflex SBS Glass Interply"or Type G2 base sheet(hot mopped or mechanically fastened). Pty Sheet(00ona0e—One or more layers"15UFLEX","Xtraflex APP S°or"POLYFLEX"(heat fused),°ELASTOBASE","XtraNex SBS GLASS Base","ELASTOFLIX V","Xtraflex SBS Glass Interply","ELASTOFLEX V-C"or Type G2 base sheet(hot mopped or mechanically fastened). Membrane-—"Polyflex G FR","XtraFlex APP G HP",heat fused. Class B-Fully Adhered I.Dedc C-15/32 Inline:1/4 Base Sheep—Two or more layers"DUFLEX",'Xtraflex APP S"or"POLYFLEX°(mechanically fastened or heat fused),"ELASTOBASE", "XtraFlex SBS GLASS Base",Type G2 GAF Building Materials"GAFGlas#75",Johns Manville"GLASBASE"or Celotex"Vaporbar GB"(mechanically fastened or het mopped In place); Membrane:—"DUFLEX°,"DUFLEX G°,"Xtraflex APP G","XtraFlex APP G HP TOR"or"POLYFLEX G°(modified bitumen),heat welgv,, 2.Decic C-15/32 • • Iiudhie:lJ2 • • 9999 9999•0 Insulation(Optional):—Any thickness,one or more layers UL Classified periite,wood fiber,glass fiber,polyL%Vy�g ir$te, ••• •••• • polyisotyanufWtomposite,EPS/wbOd fiber,EPS/perilte or 059/composite roof insulation. Base Sheet;—One or more layers Type G1 or G2. 000000 • • • Membrane:—One or more layers"POLYFLEX G FR","XtraFlex APP G HP","Xtraflex APP G FR","POLYFRESKO G IW,."ROLYBONDS,••• "POLYBOND G","POLYFLEX",'Xtraflex APP S","Xtraflex APP G",'XtraFlex APP G HP TOR"or"PLYFLEX G"(modlflegPLtQmen), • fused. •• 0999• Surfacing:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Fields"F530 Heat Shield AlumirluMa%fng"or•F6;0• 90694 • Heat Shield Fibered Aluminum Coating",1-1/2 gal/sq;or Monsey Products"Endure Aluminum Roof Coating",'WWerG eck"or�w••• •••••• Grade Aluminum Roof Coating",1-1/2 gal/sq;or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq.,followed by"PolyPius� •• 60",applied at ala-1 gal./sq. 3.Deck:C-15/32 Incline:1-1/2 • • i•••i• •••••• • • • 9999•• Bass Sheet;—Type G2 or"ELASTOBASE","XtraFlex SBS GLASS Base",mechanically fastened. " ' •' ;'; ' Pty Sheet:—"Polyglass Base",heat fused. •• • Membrane.—°POLYFLEX G PR",°XtraFlex APP G HP","Xtfafl§t APP G FR"or°POLYFRESKO G FR°(modified bitumen),heat fused. 4.Deck 15/32 Indine:1-1/2 Insulation:—Glass fiber(15/16 In.min.),mechanically fastened. Base Sheep—Type G2 base or"ELASTOBASE","XtraFlex SBS GLASS Base",hot mopped or mechanically fastened. Membrane;—WXYFLEX G W,OXt Flex APP G HP","Xtreflex APP G FRO or"POLYFRESKO G FR"(modified bitumen),heat fused. 5.Deck C-15/32 Incline: 1/2 Base Sheet:—Type G2,mechanically fastened. Membrane:—"POLYFLEX G","XtraFlex APP G HP TOR",'Xtreflex APP G"or"POLYBOND G",heat fused. 6.Deck NC Incline:1 IMUlaton(Optiormo.,—Poly190Cyanurate,any thickness. Base sheet(Optional):—"ELASTOFLEX SA V PLUS","Xtraflex SBS Base SA","ELASTOFLEX SA V"or"ELASTOFLEX SA V BASE VENT", self adhered or IELASTOBASP,"Xtraflex 5BS GLASS"Base"(poly/sand),mechanically fastened. Ply Sheet(Optional):—"POLYFLEC"or"Xtraflex APP S",heat fused. httn:I/dataha.5e_nl.cnmlr.ui-hinf��l'/fiPmnlatp/1`.1CFXT/1FR AAAF/cl,r,.xmaRP i,t7„1?.,0..,o_'T's: i��i�ni c .'1'UNA14571 -Footing Systems Page 8 of 11 Membrane:—"POLYFLEX SA P","Xtraflex APP G SA","POLYFRESKO G APP SA P","XtraFlex Kool APP G SA","ELASTOFLEX SA P", "Xtraflex SBS G SA","POLYFRESKO G SBS SA P",self-adhered or'POLYFLEX G","XtraFlex APP G HP TOR"or"Xtraflex APP G",heat fused. 7.Deck:C-15/32 Incline:1/2 Insulation(Optional);—Polyisocyanurate,any thickness. Barrier Board:—1/4-in.(min)GP Gypsum DensDeck®or DensDec k Prime®,mechanically fastened. Base sheet:—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),mechanically fastened. Ply sheet(Optional):—"ELASTOFLEX SA V PLUS","Xtraflex SBS Base SA","ELASTOFLEX SA V"or"ELASTOFLEX SA V BASE VENT", self-adhered. Membrane:——"POLYFLEX SA P","Xtraflex APP G SA","POLYFRESKO G APP SA P","XtraFlex Kool APP G SA","ELASTOFLEX SA P" "Xtraflex SBS G SA","POLYFRESKO G SBS SA P",self-adhered or'POLYFLEX G","XtraFlex APP G HP TOR"or"Xtreflex APP G",heat fused. 8.D@ck:C-15/32 Incline:1%4 Base sheet(Optional):—"ELA5TOBASE","XtraFlex SBS GLASS Base"(poly/sand),"PoiyAnchor",mechanically fastened. Pty Sheet:—"ELASTOFLEX SA V PLUS","Xtraflex SBS Base SA","ELASTOFLEX SA V"or"ELASTOFLEX SA V BASE VENT,self-adhered or "ELASTOBASE",'XtraFlex SBS GLASS Base",mechanically fastened. Membrane:—"POLYFLEX SA P","Xtraflex APP G SA","POLYFRESKO G APP SA P","XtraFlex Kool APP G SA","ELASTOFLEX SA P", "Xtraflex SBS G SA","POLYFRESKO G SBS SA P",self-adhered or'POLYFLEX G","XtraFlex APP G HP TOR"or"Xtraflex APP G",heat fused. 9.Deck NC Inciine:a Insulation:—Any UL Classified,any thickness. Barrier Board:—1/4,3/8,1J2 or 5(S-in.thick USG Corp'SECUROCK""Roof Board(Type FRX-G)" Base sheet(Optional):—"ELASTOFLEX SA V PLUS","Xtraflex SBS Base SA","ELASTOFLEX SA V"or"ELASTOFLEX SA V BASE VENT", self-adhered or"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),mechanically fastened. Ply Sheet(Optional):—"POLYFLEX"or"Xtraflex APP S",heat fused. Membrane:—"POLYFLEX SA P","Xtraflex APP G SA","POLYFRESKO G APP SA P",'XtraFlex Kool APP G SA","ELASTOFLEX SA P", "Xtraflex SBS G SA","POLYFRESKO G SBS SA P",self-adhered or'POLYFLEX G","XtraFlex APP G HP TOR"or"Xtraflex APP G",heat fused. 10.Deck:C-15/32 Incline:2 Insulation(Optional);—Pelyisocyanurate,perlite,wood fiber or poiylsocyanurate/peritte board,any thickness. Barrier Board:—1/4 in.(min)G-P Gypsum DensDeck®,mechanically fastened with all joints staggered 6 in.from the plywood joints. Base Sheet:—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),mechanically fastened,heat fused or hot mopped. Ply Sheet(Optional);—"ELASTOBASE","XtraFlex SBS GLASS Base"(poly/sand),fiiechatliitbily fastened,heat Wtd or hot mopped. Membrane.—"POLYFLEX SA P FR","POLYFRESKO G APP SA P FR","ELASTOFLEX SA P FR","POLYFRESKO G SBS SA P FR", "ELASTOFLEX SA V FR HT",(self adhered)or"POLYFLEX G FR","XtraFiex APP G HP" "Xtraflex APP G FR","POLYFRESKO G FR","DUFLEX G FR","XtraFlex APP Dual","ELASMFLEX 56G FR","POLYFRESKO G SBS Fl3","ELA 409HItLb TS G FRd,°$t Mex SB§POLY G", "XtraFlex SBS POLY G T',heat fused or hot mopped. CIM C-Fully Adhered 1.Deck:C-15/32 Incline:2 Base Sheet:—Johns Manville"Perma Ply WO(Type G2). 006000 Membrane:—"POLYBOND G","POLYFLEX G","XtraFtex APP G HP TOR","Xb-aflex APP G","POLYFRESKO G FRI"Xt�aflix AAP G PW?• *000:0 "Xtra-Flex APP G HP"or"POLYFLEX G FR"(modified bitumen),heat welded. •• • ••• • so Class A-Mechanically Fastened •••••• •• :00 ••••• • 1.Deck;NC Incline: 1 •••••• • i••••i •••• •••• • • • • • • Insulation(Optiona l).—Poi Isocyanurate,peHite,wood fiber or polytsocyanurete/perlibe,any thickness. • •• 0000• 69666 . . Membrane:—"TPOFLEX G FR",mechanically fastened. *0:00: • •• ••••• 2.beciu NC Incline:1-1/2 •• •• ••••• 00000 •••:• Insulation:—Polyisocyanurate,periite,wood fiber or poiyisocyonurata(perlite,any thickness. • • • • •••••• Base Sheen—One or more pllesType G2,hot mopped or mechanically fastened. • ;••••• • Membrane,—IWFLEX G FR",mechanically fastened. • • • •••••• 00 0 0 669 OTHEit SYSTEMS • • • 1.Deck:C-15/32 or spaced sheathing Incline:Unlimited Underlaymennt:—One layer Elk Corp"VersaShield",mechanically fastened. Ply Sheet:—One ply"Poiystick MTS"(self adhered). Surfacing:—Any UL Listed or Oassifled copper or steel standing seam panels or shingles,26 gauge min. 2.Deck:NC Incline:Unlimited Insulation:—Any UL Classified polyisocyanurate,any thickness. Underlayment:—One ply"Polystick MTS"(self adhered). Surfacing:—Any UL Listed or Classified copper or steel standing seam panels or Shingles,26 gauge min. PLUM APPLIED COATIIMA SYSTEMS Class A 1.Deck;C-15/32 Incline: 1 /T Tf1Tt7T/1 TTl ♦1 m/ 1 1 1n m.r . ........... .'1'UFILIA14571 -Rooting Systems Page 9 of 11 Insulation(Optional):—Polyisocyanurate,urethane,periite/polyisocyanurate composite,periite/urethane composite,glass fiber, phenolic or perlite,any thickness. Barrier Board:—1/4 in.min.G-P Gypsum"DensDeck®",Certaffeed Gypsum"GlasRoc"or USG"SECUROCKO"glass mat board, Base Coat:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gat/sq.or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq. Top Coat:—"PolyBrite 70"or"XtraFlex White Elastomeric Roof Coating",applied at 1.5 gal./sq. 2.Deck:C-15/32 Incline:1 Insulation(Optional):—Polylsocyanurate,urethane,perllte/polylsocyanurate composite,perlita/urethane composite,glass fiber) phenollt or pe ite,any thickness. Barrier Board:—1/4 in.min.G-P Gypsum"DensDeck®",CertainTeed Gypsum"GlasRoc"or USG"SECUROCKO"glass mat board Base Coat:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq. Top Coat:—"PolyPlus 60"or"XtraFlex Aluminum Roof Coating",applied at 3/4-1 gal./sq. 3.Deck NC Inclines 2 Insulatlem—Johns Manville"ENRGY II,"any thickness. Ply Sheet:—One or more piles polyester ply sheets embedded Into primer. Coatings—"Polybrite 95 Silicone,""XtraFlex SRC 8000""Polybrite 90 High Solids Silicone"or'XtraFlex SRC 9600"series applied 2 to 3-gal/100-fe. MAINTENANCE AND REPAIR SYSTEMS Class A,B and C 1.Deck C-15/32 Incline:1 Exleting Roof System:—(To maintain existing Classifications)-Any Class A,B or C,uncoated,Insulated or uninsulated,modified bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq. Top Coab—"PolyBrlte 70"or"XtraFlex White Elastomeric Roof Coating",applied at 1.5 gal./sq. 2.Deck C-15/32 Incline:1 Existing Roof System:—(To maintain existing Classifications)-Any Class A,8 or E,uncoated,insulated or uninsulated,modified bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat:—"PG 800 Asphalt Emulsion Roof Coating",applied at 3-4 gal/sq.or Brewer"Fortress 5001 Asphalt Emulsion",applied at 4 gal./sq. Top Coat:—"PolyPlus 60"or"XtraFlex Aluminum Roof Coating",applied at 314-1 gal./sq. 3,Declu C-15/32 Incline:Sep Note 1 Existing Roof System:—Any UL Classified existing single-ply membrane system,to retain existing Classification,covered witV Surfacing*—"Polybrite 95 Siiteotle,"°xtpaFieX SRC 8000,""Polybrite 90 High Solids§intone"or"XtraFlex SRC•9600"•series appl"fal• •••••• S1h-gal/100-ftz. . . . • •• • ••• • • Note 1:Cla3i112atlbh(A,B or C)and maximum incline will be the same as that of the Classified Roofing System }! •• •••••• 4.Deck C-15/32 Incline:I/z •••••• • i••••i •••• •••• • • ExistingRoof g • • • • System*—Any UL Classified existing single-ply membrane system,to retain existln Classificotiofr'�o�ered with-* '•:••. Surfacing:—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC•9G®0"•s`ries appeg tie• •"'• 11/2-gal/10041:2. •• •• •••• e••••• • ASPHALT FELT SYSTEMS wrrH HM ROOFING ASPHALT •••••• • • 1.Deck:NC Incline:3 ••• i • ••• i••• i • • • Sale Sheets—"Polyglass Vented Base","Polyglass G2 Base","Polyglass Ply 4","Polyglass Ply 60,'XtraFlex G2 Base","XtraFlex Ply VI; "XtraFlex Ply IV,"mechanically fastened or hot mopped.May use Black Warrior Rooflng Inc"Modifted BUR Asphalt". Insulation(Optional):—Periite or glass fiber,any thickness,mechanically fastened or hot mopped.May use Black Warrior Roofing Inc "Modified BUR Asphalt". Ply Sheets:—One or more layers"Polyglass G2 Base","Polyglass Ply 4","Polygiass Ply 6","XtreFlex G2 B " "XtraFlex Pi VI"or "XtraFlex Ply IV". asey Surfacing:—Gravel,crushed stone or crushed slag,In a flood coat of hot roofing asphalt. SPRAY APPLIED FOAM AND COATING SYSTEMS Systems utilizing United Coatings Manufacturing Co."Diathon"or"Acron FR"acrylic roof coatings as a surfacing may be surfaced with an additional coat of same applied at i-gal/100-fe into which No.11 roofing granules are embedded Into the wet coating broadcast applied at rate of 45-Ib/100-ft2. United Coatings Manufacturing Co."Diathon"or"Acron FR"or acrylic roof coating may incorporate chopped glass fiber strands which are added during application of coating. "Polybrite 90 High Solids Silicone"or"IXtraFlex SRC 9600"series silicon roof coating may be used In lieu of"Polybrite 95 Silicone"or"XtraMex SRC 8000"series silicone roof coating In any applicable system. Nil++.���wLr.L......1-1 1-!-117NY'1714_... _1.1 /T TrIT*WTT/1T I1 -1 � • •.. - 1 1 V1'kjal I`td I 1 -1\.VV11LLg L1ybLULM rage lU Ut 11 Class A noncombustible deck ratings 45-56 may be used as Maintenance and Repair Systems when applied over an existing roof system and maintain the existing Classification,providing a minimum 1%-In.thickness of foam Is utilized.A barrier board consisting of'A-In.thick(minimum) gypsum board or 1/4-in.thick(minimum)G-P Gypsum Corp."DensDeck @ Roofboard"or"DensDeck Prime®Roofboard"or"DensDeck DuraGuard1°'Roofboard"may be used In any existing noncombustible deck Classification.When this Is done,the resulting roofing system is acceptable for use over combustible(15/32-In.minimum)roof decks.The butt joints In the barrier board frust be offset a rmfilmuM of 6-1h."M butt joint In the roof deck. BASF Polyurethane Foam Enterprises LLC"FE303"or TE348"or"Premium 241"Series(may include have the suffik"R,""S,""F,"or"W")sit acceptable alternates to Coating&Foams Solutions L L C"RT-2716"Series. Bayer Material Science,LLC"SC-200"or"SH-200-25/30°or"524525/30"or"B&MBI 2.5""B8y3e8l 2.7"or"Bayseal 3.0"or"SW200-25/30" Series(may Include the suffix"R;"S,""F"or"W")are acceptable alternates to Coating&Foams Solutions L L C"RT-2717"Series. Burtin Polymer Laboratories,Inc."BPL 1120"or"BPL 1445"Series(may Include the sufFht"Rr"S,°"F,"or"W`)are acceptable alternates to Coating&Foams Solutions L L C"RT-2718"Series. Claw A 1.Deck NC Incline:3 Foam:—BASF Polyurethane Foam Enterprises LLC"FE 303"any thickness. Base Coat—"Polybrite 95 Silicone,""XtraFlex SRC 8000","Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at 11/rgal/100-fO. Top Cost:—"Polybrite 95 Silicone,""XtraFlex SRC 8000","Polybrite 90 High Solids Silicone"or°XtraFlex SRC 9600"series applied at 1"ai/10o-ft?. 2.Decfc NC Incline:1 Foamy—Coating&Foams Solutions L L C"RT-2716,"2.5 to 3.0-Ib/R3-Ib/ft3,iyh-to 2-in.thick. Surfacing:—"Polybrtte 95 Silicone,""XtraFlex SRC 8000","Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at 21/4-gal/100-ft?. 3.Deck:NC Incline:3/4 Foam:—Coating&Foams Solutions L L C"RT-2717,"2.5 to 3.0-Ib/ft3-Ib/ft3,11h-to 2-in.thick. Surfacing:—"Polybrite 95 Silicone,""XtraFlex SRC 8000","Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at 21/4-gal/10041:2. 4.Deck:NC Incline:1 Foam:—Coating&Foams Solutions L L C"RT-2718"any thickness. Base Coat—"Polybrlte 95 Silicone"or'XtraFlex SRC 8000"silicone roof coating or Neogard's"7860-01°or Dow Corning Corp's "3-5000"or Dow Corning Corp's"3-4000"applied at V/rgal/100-ftz. Top Coat—'Polybrite 95 Silicone"or"XtraFlex SRC 8000"silicone roof coating or Neogard s"7860-01"or Dow Coming Corp's"3-5000" or Dow Corning Corp's 03-4000"applied at 11A-gal/100-ftz. 5.Deck NC Kline:3 ••••• • • 0000 0000•• Foam:—Coating&Foams Solutions L L C°RT-2718"any thickness. •• ••• • • Base Coat—"Polybrite 95 Silicone"or"XtraFlex SRC 8000"silicone roof coating or Neogard's 7860-01"or Dex COMIll ig Corp's •• •••••• °3-5000"or Dow Coming Corp's 03-4000"or applied at 11h-gal/100-fta. *so:** • Top Coate—"Polybrite 95 Silicone'or"XtraFiex SRC 8000"silicone roof coating or Neogard's"7860-01"or Dow,,4"ng Corp's or Dow Coming Corp's"3-4000"or applied at 11/2-gal/10041:2. . • • Surfacing:—Broadcast application of No.11 ceramic coated roof granules applied at 30-Ib/100-ft2. see* 4.9 0 �.� • Class f000•• •• ••• •,•., • • • Any of the following Class B systems may be considered as Class A combustible deck assemblies when a rein of 400-Ib99f�ta4e1 15 applied d5 a surfacing and gravel is maintained. • • . • • • • . 0000•• 0000•• 1.Deck:C-15/32 Incline;1/2 • • • • • • • • 0000•• •• • • 4, • • Foam:—Coating&Foams Solutions L L C"RT-2716"1V2-in.minimum. 0009 Base Coat:—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraMex SRC 96001 series applied at 1%-gal/100-ft's. Top Coab—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600°series applied at 11h-gal/10041:2. Surfacing:—No.11 roofing granules embedded Into wet coating applied at 30-Ib/100-ft2. 2.Decks C-15/32 Incline: 1/4 Foam:—Coating&Foams Solutions L L C"RT-2717,"2.5 to 3.0-Ib/ft?,2-in. Base Coat—"Polybrite 95 Sllicone,""XtraFlex SRC 8000,1"Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at 3A to 1-gal/10o-fl?. Top Coeb—"Polybrite 95 Silicone,"'XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series applied at% to 1-gal/100-ft2. Surfacing:—No.ii roofing granules embedded into wet coating applied at 25-ib/100-FLI. 3.Deck:C-15/32 Incline:1/2 Foam:—Coating&Foams Solutions L L C"RT-2716,"2.5 to 3.2-Ib/ft3,1V2-in,minimum. „1 -/n Ti lei«lVV�T/+n..nwln+i./T TQTV17/117T) A A AT?/-'L 1 101inn 10 f TU U X1071 Kootmg systems rage 11 01 11 t Base Coat:—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series or BASF 113-5000"or"BPFE 3-5000"or Dow Coming"3-5000"applied at 11h-gal/100-1`0. Top Coats—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series or BASF 03-5000"or"BPFE 3-5000"or Dow Corning"3-5000"applied at SYz-gal/100-fta. Surfacing:—No.11 roofing granules embedded Into wet coating applied at 30-Ibs/100-ft2. 4.Deck C-15/32 Inclines% Insulation:—Minimum 1-in.thick Coating&Foams Solutions L L C"RT-2718"(2Va to 3.0214-lb/1`1:3)spray applied foamed plastic. Base Coats—"Polybrite 95 Silicone,""XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series silicone roof coatings or United Coatings Manufacturing Co."Dlathon"or"Dlathon HT"or"Acron FR"acrylic roof coatings or General Electric Inc."SCM- 3400"$Giles silicone roof coating or Neogard"7860-01"series silicone roof coating or Dow Comng Corp."3-4000"or 3-5000"silicone roof coating applied at 1%-gal/100-e. Top Coat:—"Polybrite 95 Silicone,"."XtraFlex SRC 8000,""Polybrite 90 High Solids Silicone"or"XtraFlex SRC 9600"series silicone roof coatings or United Coatings Manufacturing Co."Diathon"or"Dlathon HT"or"Acron FR"acrylic roof coatings or General Electric Inc."SCM- 3400"series silicone roof coating or Neogard 07860-01"series silicone roof coating or Dow Coming Corp.03-4000"or 3-5000"silicone roof coating applied at 1V2-gal/100-fe. Surfacing:—Broadcast application of No. 11 ceramic coated granules applied at a rate of 30 to 50-lbs/100-f1?. Last Undated on 2014-10-14 Ouestions? Print this pace Terms of Use Pace To p 2014 UL LLC When the UL Leaf Mark is on the product,or when the word"Environment"is included In the UL Mark,please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product In this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service.Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information,Assemblies,Constructions,Designs,Systems,and/or Certifications(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data(or drawings).2.The statement"Reprinted from the Online Certifications Directory with permission from UL"must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice in the following format:V 2014 UL LLC". 0000 • a 0000 0000•• • • • 0000•• •• 0000•• • 0000•• • • • •0666• 0000 •0.6 6••0• 0000•• • •6 ••••6 06 60 0000 •660•• • 60•••• • • • • • • •066•• • • • 6.6••6